CAP WITH
TEST POINT
GROUNDING PLUG
CABLE
ADAPTER
INSULATED
PARKING BUSHING
1) The document discusses 600-Amp elbow connectors and other 600 Series deadbreak components used to connect cables and equipment on primary circuits, featuring bolted connections and modular construction.
HOTSTICK OPERABLE 600 SERIES
CONNECTORS - SEE PAGES H-14–H-17
THREADED
COMPRESSION LUG
STICK-OP LOADBREAK
REDUCING TAP PLUG
2) Components allow for visible external separation, bypass, isolation, dead-ending, grounding, testing, and adding taps, surge
Nexans Euromold 600 series screened separable connectors are EPDM pre-moulded, high voltage cable terminations for 6.6kV, 11kV, 15kV and 24kV electrical equipment including switchgear, transformers and motors.
Nexans Euromold 600 series separable connectors include Nexans Euromold bolted tee connectors and Nexans Euromold bushings (oil and air insulated) for electrical equipment up to 24kV - 1250A. Nexans Euromold 600 series connectors are specified to terminate and connect polymeric (XLPE or EPR) screened (copper tape and wire) cables to ANSI-style Interface Type D (800amp) bushings with either copper or aluminium 5/8" bolted connection.
Euromold Connectors 400 Series Interface Type C Bushing - 630Amp
* Connector Type : M16 Bolted Copper Insert
* Voltage Range : 11/12kV-33/36kV
* Current Rating : 630amps
* Specification : CENELEC EN50180 & EN50181
Euromold 430TB Elbow Connectors are used with 400 Series Interface C Bushing.
700 Series Interface E Elastimold Cable Connectors and Bushings connect and terminate HV cables to Interface E bushings on switchgear and transformers. Elastimold provide high voltage cable accessories to suit the 7 main bushing interfaces : A, B, C (Compact), C (Symmetrical), D, E and F. Elastimold cable joints, cable terminations, epoxy bushings, angled (elbow) and straight plug-in or bolted separable connectors for connecting, jointing and terminating high voltage cables. 700 Series Interface E, Elastimold Bushings * Bushing Voltage Range 33kV-36kV * Bushing Current Rating 800Amps & 1250Amps * Bushing Type 5/8" Bolted Aluminium Insert Elastimold separable elbow connectors are high voltage cable terminations used to connect polymeric (XLPE or EPR insulated) power cables to HV equipment including transformers, switchgear, capacitors and motors. 700 Series Connectors - 750LR Tee Connectors & 775LR Tee Connectors 800-1250Amps 35-630sqmm Slip on cable connectors - quick to install to high voltage switchgear and transformers (oil, air and gas insulated) Touchproof cable terminations - made from conductive EPDM rubber, fully screened HV termination for safety One part cable termination - built-in stress relief, insulation and outer semi-conductive layers Maintenance friendly - readily disconnectable cable connector for high voltage maintenance work Compact cable connectors - space-saving HV cable terminations for SF6 gas insulated switchgear (GIS) EPDM rubber cable connectors - resistant to ozone, corona, chemicals, water and atmospheric pollutants Flexibility - Elastimold cable connectors are disconnectable and re-useable. Re-use of the Elastimold high voltage cable connector permits site re-location of HV electrical equipment without requiring cable re-termination. HV High Voltage Cable Connectors, Specification - Elastimold dead-break separable cable connectors suit all international high voltage bushing interfaces for the termination of HV cable into switchgear, transformers and motors. Elastimold cable connectors terminate high voltage power cables (typically 11kV, 15kV, 24kV, 33kV, 36kV up to 52kV) into SF6 GIS gas insulated switchgear including Schneider, ABB, Areva and Siemens. Elastimold cable connectors meet the requirements of ANSI/IEEE 386 & 404 and CENELEC EN50180 & EN50181 for high voltage "dead-break" cable connection, i..e connectors installed and terminated onto un-energised high voltage power cable. US specification "load-break" cable connectors for high voltage energised cable termination are available. High Voltage Cable Connectors - Elastimold cable connectors (elbow and straight types) are specified to terminate XLPE or EPR insulated high voltage power cables with copper tape or copper wire screens up to 52kV. Elastimold cable connectors are available to suit and terminate lead covered HV cables for hydro-carbon industries (oil, gas, petrochemicals) with ATEX certification for hazardous area Zones 1 and Zones 2.
Underground Cable Accessories
Elastimold® offers the industry's most complete package for managing underground cable connections.
Broad Product Range..
Elastimold accessories, available from 5kV to 138kV, connect, ground, splice, terminate and protect underground cable.
Elastimold Innovation
Elastimold’s long, innovative history includes pioneering such products as extended and repair elbows, jacket seal elbows, and shrink-fit joints.
MV Switchgear provides centralized control and protection of medium-voltage power equipment and circuits in industrial, commercial, and utility installations involving generators, motors, feeder circuits, and transmission and distribution lines.
SPS High Voltage Cable Termination Kit List (Typical) - Three Core Cables
XLPE EPR HV Termination Kits
Anti-track heat shrink 3 core tubes x 3
Stress control heat shrink 3 core tubes x 3
Yellow stress relief tape for screen ends x 3
3 core heat shrink cable breakout boot x 1
Red mastic sealing tape x 1
Cable cleaning and de-greasing wipes x 3
Box, label, jointing instructions x 1
HV Termination Kits Optional Extras, 3 Core 6.6-7.2kV - Solderless Earth Kit for Copper Tape Screen Cables, Insulating Bushing Boots (Straight, Right Angled, Universal), HV Cable Glands for SWA Cable (Bolt-on Top Hat), Outdoor Armour Earthing Kit, Outdoor Stand-off Brackets + Insulators, High Voltage HV Cable Lugs (Crimp or Mechanical Shearbolt Lugs).
SPS High Voltage Heat Shrink Cable Termination Kits, 6.6-7.2kV - Testing
SPS high voltage heat shrink termination kits for 3 core HV cables (XLPE and EPR) are Tested and Certified to latest International Test Standards as outlined in Cenelec standards HD 628 S1 and 629.1 S2 : 2006 - high voltage cable termination kit testing also encompasses VDE 0278 and IEC 60502.
Nexans Euromold 600 series screened separable connectors are EPDM pre-moulded, high voltage cable terminations for 6.6kV, 11kV, 15kV and 24kV electrical equipment including switchgear, transformers and motors.
Nexans Euromold 600 series separable connectors include Nexans Euromold bolted tee connectors and Nexans Euromold bushings (oil and air insulated) for electrical equipment up to 24kV - 1250A. Nexans Euromold 600 series connectors are specified to terminate and connect polymeric (XLPE or EPR) screened (copper tape and wire) cables to ANSI-style Interface Type D (800amp) bushings with either copper or aluminium 5/8" bolted connection.
Euromold Connectors 400 Series Interface Type C Bushing - 630Amp
* Connector Type : M16 Bolted Copper Insert
* Voltage Range : 11/12kV-33/36kV
* Current Rating : 630amps
* Specification : CENELEC EN50180 & EN50181
Euromold 430TB Elbow Connectors are used with 400 Series Interface C Bushing.
700 Series Interface E Elastimold Cable Connectors and Bushings connect and terminate HV cables to Interface E bushings on switchgear and transformers. Elastimold provide high voltage cable accessories to suit the 7 main bushing interfaces : A, B, C (Compact), C (Symmetrical), D, E and F. Elastimold cable joints, cable terminations, epoxy bushings, angled (elbow) and straight plug-in or bolted separable connectors for connecting, jointing and terminating high voltage cables. 700 Series Interface E, Elastimold Bushings * Bushing Voltage Range 33kV-36kV * Bushing Current Rating 800Amps & 1250Amps * Bushing Type 5/8" Bolted Aluminium Insert Elastimold separable elbow connectors are high voltage cable terminations used to connect polymeric (XLPE or EPR insulated) power cables to HV equipment including transformers, switchgear, capacitors and motors. 700 Series Connectors - 750LR Tee Connectors & 775LR Tee Connectors 800-1250Amps 35-630sqmm Slip on cable connectors - quick to install to high voltage switchgear and transformers (oil, air and gas insulated) Touchproof cable terminations - made from conductive EPDM rubber, fully screened HV termination for safety One part cable termination - built-in stress relief, insulation and outer semi-conductive layers Maintenance friendly - readily disconnectable cable connector for high voltage maintenance work Compact cable connectors - space-saving HV cable terminations for SF6 gas insulated switchgear (GIS) EPDM rubber cable connectors - resistant to ozone, corona, chemicals, water and atmospheric pollutants Flexibility - Elastimold cable connectors are disconnectable and re-useable. Re-use of the Elastimold high voltage cable connector permits site re-location of HV electrical equipment without requiring cable re-termination. HV High Voltage Cable Connectors, Specification - Elastimold dead-break separable cable connectors suit all international high voltage bushing interfaces for the termination of HV cable into switchgear, transformers and motors. Elastimold cable connectors terminate high voltage power cables (typically 11kV, 15kV, 24kV, 33kV, 36kV up to 52kV) into SF6 GIS gas insulated switchgear including Schneider, ABB, Areva and Siemens. Elastimold cable connectors meet the requirements of ANSI/IEEE 386 & 404 and CENELEC EN50180 & EN50181 for high voltage "dead-break" cable connection, i..e connectors installed and terminated onto un-energised high voltage power cable. US specification "load-break" cable connectors for high voltage energised cable termination are available. High Voltage Cable Connectors - Elastimold cable connectors (elbow and straight types) are specified to terminate XLPE or EPR insulated high voltage power cables with copper tape or copper wire screens up to 52kV. Elastimold cable connectors are available to suit and terminate lead covered HV cables for hydro-carbon industries (oil, gas, petrochemicals) with ATEX certification for hazardous area Zones 1 and Zones 2.
Underground Cable Accessories
Elastimold® offers the industry's most complete package for managing underground cable connections.
Broad Product Range..
Elastimold accessories, available from 5kV to 138kV, connect, ground, splice, terminate and protect underground cable.
Elastimold Innovation
Elastimold’s long, innovative history includes pioneering such products as extended and repair elbows, jacket seal elbows, and shrink-fit joints.
MV Switchgear provides centralized control and protection of medium-voltage power equipment and circuits in industrial, commercial, and utility installations involving generators, motors, feeder circuits, and transmission and distribution lines.
SPS High Voltage Cable Termination Kit List (Typical) - Three Core Cables
XLPE EPR HV Termination Kits
Anti-track heat shrink 3 core tubes x 3
Stress control heat shrink 3 core tubes x 3
Yellow stress relief tape for screen ends x 3
3 core heat shrink cable breakout boot x 1
Red mastic sealing tape x 1
Cable cleaning and de-greasing wipes x 3
Box, label, jointing instructions x 1
HV Termination Kits Optional Extras, 3 Core 6.6-7.2kV - Solderless Earth Kit for Copper Tape Screen Cables, Insulating Bushing Boots (Straight, Right Angled, Universal), HV Cable Glands for SWA Cable (Bolt-on Top Hat), Outdoor Armour Earthing Kit, Outdoor Stand-off Brackets + Insulators, High Voltage HV Cable Lugs (Crimp or Mechanical Shearbolt Lugs).
SPS High Voltage Heat Shrink Cable Termination Kits, 6.6-7.2kV - Testing
SPS high voltage heat shrink termination kits for 3 core HV cables (XLPE and EPR) are Tested and Certified to latest International Test Standards as outlined in Cenelec standards HD 628 S1 and 629.1 S2 : 2006 - high voltage cable termination kit testing also encompasses VDE 0278 and IEC 60502.
UNIT - 05 DISTRIBUTION LINES AND TRANSFORMER CENTREPremanandDesai
Code of practice for Distribution Lines and Transformer centre, types of transformer centres -
Pole mounted, plinth mounted, indoor and outdoor types. Determining the rating of
Distribution Transformer. Write Specifications of the Distribution Transformer. Draw the
SLD of a Transformer centre indicating the size of protective devices, Prepare the schedule of
equipments /Materials with specifications for a 11KV/415V,100 KVA transformer centre and
their estimates, 415 V LT line materials and specifications , method of calculating various LT
line materials (only). Prepare the schedule of materials (only) for 3 phase 4 wire LT line,
11 KV HT Line-materials and their specifications, method of calculating various HT line
materials and tapping structure, TOPO sheet and its use, Concept of combined estimates.
Prepare the schedule of materials (only) for 11 KV single circuit HT line for Rural
Electrification.
(Note: HT lines over head type only)
RAYCHEM SAUDI ARABIA LTD. (TYCO ELECTRONICS) |AKBAR TRADING EST. SAUDI ARABIA...AKBAR TRADING
te connectivity saudi arabia
TYCO TERMINATION KIT IN ALL VOLTAGE
Raychem terminations for polymeric and MIND
paper insulated cables from 7.2 kV up to 36 kV
System Designer
케이블 종단-거-瑞侃工具包电缆终端-阿克巴交易
ชุด การเลิกจ้าง
RAYCHEM SAUDI ARABIA LTD. (TYCO ELECTRONICS)
11kV-33kV Medium Voltage Heat Shrink Cable Joints & Cable Terminations
11kV and 33kV heat shrink cable joints and cable terminations for medium voltage power cables - SPS heat shrink cable joints and cable terminations are suitable for installation at indoors and outdoors in the Middle East countries, this includes salt laden and dusty atmospheres associated with the Middle East oil, gas and petrochemical industries. Cable terminations and cable joints are suitable for XLPE and paper insulated single core and three 3 core cables of 11kV and 33kV voltages, 3 phase, 50HZ type electrical systems with highest system voltages of 12kV and 36kV. Cable joints are suitable for connecting two XLPE insulated cables of same size or dissimilar sizes and for transition between XLPE and paper insulated lead covered (PILC) medium voltage cables.
he apparatus used for switching, controlling and protecting the electrical circuits and equipment is known as switchgear. Switches, fuse, circuit breaker, relay, isolator this are some essential switchgear used in domestic and industrial application.
Basics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protection
Medium Voltage Terminations- up to 42kV.| AKBAR TRADING EST.| mail@akbartradi...AKBAR TRADING
Cold Applied:
• TFTI-TFTO:
Single Core Polymeric Cable Termination - Pre Expanded on Holdout - up to 42kV
• TFTI-TFTO:
Single Core Polymeric Cable Termination - Push On - up to 42kV
Heat Shrinkable:
• IXSU/OXSU:
Uniterm - Terminations for Polymeric Cables - up to
42kV
Uniterm - Terminations for Polymeric Cables - up to
42kV - Selection Guide
• IXSU/OXSU - EPKT Quick Reference Guide
Heat Shrinkable Elbows:
• EPKT:
Heat Shrinkable Termination System for cables up to 36kV
Heat Shrinkable Termination Selection Guide
• RSRB:
Inline Bushing Boots
• RSRB:
Right Angle Bushing Boots
Inline & Right Angle Bushing Boot Selection Guide
Push On Elbows:
• RCAB:
Elastomeric Flexible Bushing Boot - up to 17.5kV ONLY
• RCAB:
Inline Cold Applied Boot - up to 24kV ONLY
• RICS:
Insulated Elbow Adaptors - up to 24kV
Insulated Elbow Adaptors - up to 24kV - Selection Guide
• RSES/RSSS:
Insulated Screened Elbows - 250A - up to 24kV
• RSTI:
Insulated Screened Elbows - 630A - up to 24kV
• RSTI:
Insulated Screened Elbows - 630A - up to 36kV
• RSTI:
Insulated Screened Elbow - Piggyback Coupling System - up to 36kV
GURO MV:
NEW
GUROFLEX Medium Voltage - Cold pour Insulating Compound
Section 4:
Energy Division
http://energy.tycoelectronics.com
Nexans Euromold Connectors & Bushing Interfaces
Euromold Connectors 200 Series Interface Type A Bushing
* Connector Type : 7.9mm Plug-In Pin Contact
* Voltage Range : 11/12kV-24kV
* Current Rating : 250amps
* Specification : CENELEC EN50180 & EN50181
Euromold 158LR Elbow Connectors are used with 200 Series Interface A Bushing.
Euromold Connectors 400 Series Interface Type B Bushing
* Connector Type : 14mm Plug-In Pin Contact
* Voltage Range : 11/12kV-33/36kV
* Current Rating : 400amps
* Specification : CENELEC EN50180 & EN50181
Euromold 400LR Elbow Connectors are used with 400 Series Interface B Bushing.
UNIT - 05 DISTRIBUTION LINES AND TRANSFORMER CENTREPremanandDesai
Code of practice for Distribution Lines and Transformer centre, types of transformer centres -
Pole mounted, plinth mounted, indoor and outdoor types. Determining the rating of
Distribution Transformer. Write Specifications of the Distribution Transformer. Draw the
SLD of a Transformer centre indicating the size of protective devices, Prepare the schedule of
equipments /Materials with specifications for a 11KV/415V,100 KVA transformer centre and
their estimates, 415 V LT line materials and specifications , method of calculating various LT
line materials (only). Prepare the schedule of materials (only) for 3 phase 4 wire LT line,
11 KV HT Line-materials and their specifications, method of calculating various HT line
materials and tapping structure, TOPO sheet and its use, Concept of combined estimates.
Prepare the schedule of materials (only) for 11 KV single circuit HT line for Rural
Electrification.
(Note: HT lines over head type only)
RAYCHEM SAUDI ARABIA LTD. (TYCO ELECTRONICS) |AKBAR TRADING EST. SAUDI ARABIA...AKBAR TRADING
te connectivity saudi arabia
TYCO TERMINATION KIT IN ALL VOLTAGE
Raychem terminations for polymeric and MIND
paper insulated cables from 7.2 kV up to 36 kV
System Designer
케이블 종단-거-瑞侃工具包电缆终端-阿克巴交易
ชุด การเลิกจ้าง
RAYCHEM SAUDI ARABIA LTD. (TYCO ELECTRONICS)
11kV-33kV Medium Voltage Heat Shrink Cable Joints & Cable Terminations
11kV and 33kV heat shrink cable joints and cable terminations for medium voltage power cables - SPS heat shrink cable joints and cable terminations are suitable for installation at indoors and outdoors in the Middle East countries, this includes salt laden and dusty atmospheres associated with the Middle East oil, gas and petrochemical industries. Cable terminations and cable joints are suitable for XLPE and paper insulated single core and three 3 core cables of 11kV and 33kV voltages, 3 phase, 50HZ type electrical systems with highest system voltages of 12kV and 36kV. Cable joints are suitable for connecting two XLPE insulated cables of same size or dissimilar sizes and for transition between XLPE and paper insulated lead covered (PILC) medium voltage cables.
he apparatus used for switching, controlling and protecting the electrical circuits and equipment is known as switchgear. Switches, fuse, circuit breaker, relay, isolator this are some essential switchgear used in domestic and industrial application.
Basics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protectionBasics of busbar protection
Medium Voltage Terminations- up to 42kV.| AKBAR TRADING EST.| mail@akbartradi...AKBAR TRADING
Cold Applied:
• TFTI-TFTO:
Single Core Polymeric Cable Termination - Pre Expanded on Holdout - up to 42kV
• TFTI-TFTO:
Single Core Polymeric Cable Termination - Push On - up to 42kV
Heat Shrinkable:
• IXSU/OXSU:
Uniterm - Terminations for Polymeric Cables - up to
42kV
Uniterm - Terminations for Polymeric Cables - up to
42kV - Selection Guide
• IXSU/OXSU - EPKT Quick Reference Guide
Heat Shrinkable Elbows:
• EPKT:
Heat Shrinkable Termination System for cables up to 36kV
Heat Shrinkable Termination Selection Guide
• RSRB:
Inline Bushing Boots
• RSRB:
Right Angle Bushing Boots
Inline & Right Angle Bushing Boot Selection Guide
Push On Elbows:
• RCAB:
Elastomeric Flexible Bushing Boot - up to 17.5kV ONLY
• RCAB:
Inline Cold Applied Boot - up to 24kV ONLY
• RICS:
Insulated Elbow Adaptors - up to 24kV
Insulated Elbow Adaptors - up to 24kV - Selection Guide
• RSES/RSSS:
Insulated Screened Elbows - 250A - up to 24kV
• RSTI:
Insulated Screened Elbows - 630A - up to 24kV
• RSTI:
Insulated Screened Elbows - 630A - up to 36kV
• RSTI:
Insulated Screened Elbow - Piggyback Coupling System - up to 36kV
GURO MV:
NEW
GUROFLEX Medium Voltage - Cold pour Insulating Compound
Section 4:
Energy Division
http://energy.tycoelectronics.com
Nexans Euromold Connectors & Bushing Interfaces
Euromold Connectors 200 Series Interface Type A Bushing
* Connector Type : 7.9mm Plug-In Pin Contact
* Voltage Range : 11/12kV-24kV
* Current Rating : 250amps
* Specification : CENELEC EN50180 & EN50181
Euromold 158LR Elbow Connectors are used with 200 Series Interface A Bushing.
Euromold Connectors 400 Series Interface Type B Bushing
* Connector Type : 14mm Plug-In Pin Contact
* Voltage Range : 11/12kV-33/36kV
* Current Rating : 400amps
* Specification : CENELEC EN50180 & EN50181
Euromold 400LR Elbow Connectors are used with 400 Series Interface B Bushing.
Nexans Euromold 600 series high voltage bushings feature 5/8" threaded bushings for in air installed HV equipment including transformers, switchgears and capacitors. Nexans Euromold bushings are moulded from epoxy resin in accordance with CENELEC EN 50181.
Nexans Euromold bolted type equipment bushings meet the requirements of IEC137, IEC71 and ANSI/IEEE std. 386.
* Nexans Euromold Bushings 600TBC 11kV 12kV
* Nexans Euromold Bushings K600TBC 24kV
Elastimold - HV High Voltage Joints, Terminations, Loadbreak & Deadbreak Connectors.
Load Break Elbows
A load break elbow when used with a hot stick can be connected or disconnected at high voltage under load, but can only be used with up to a 250kcmil cable. At 100% insulation level, a 250kcmil is good for 345A in underground duct, so you would be de-rating your system by using a 200A elbow with a 250kcmil cable, but they are still widely used due to the flexibility given to the high voltage distribution system at the equipment. Think about it…if you had a critical application where power disruptions were extremely costly and maintenance was required on up-stream equipment in, let’s say a non critical area, this product would be great. You could disconnect the load without disturbing the critical portions, perform the maintenance and then reconnect it. Just make sure to take safety precautions, making and breaking electrical connections under load is very dangerous. The load break elbow is typically not used in man-holes, because it does not allow expansion like the dead break elbow. The construction of the load break elbow does not allow it to be connected to other elbows, but the dead break does.
Dead Break Elbows
A dead break or “hammerhead” elbow can only be disconnected when not under load, this is because you need to actually unscrew a pin to detach it. It would be pretty tough to unscrew the pin with a hot stick and the arc from the disconnected load, if under load, would be pretty substantial. A dead break elbow allows an increased current rating (up to 600A) and can be used on basically all cable types. At 100% insulation level a 750kcmil cable is rated 610A in underground duct. When would you use a 750kcmil? In most non-utility cases you would design or install sets of 500kcmil or smaller if you needed more than one 500kcmil could handle. Even from a 1200A breaker, two sets of 500kcmil per phase would be sufficient for distribution (about 1000A), if the load was even that high. Most of the time you set the relays down to the actual load in order to limit the copper used. A dead break when used in man-holes for splicing cables allows the flexibility of connecting more than two cables together as well as future expansion if required. Say another building was added that needed power, you could just connect that building to the existing array of dead break elbows. This also works great when temporary power is needed for construction or even if the circus is in town and they need medium voltage (it happens!). They can pick up power from the man-hole with the dead break elbows or from a piece of equipment with dead break elbows. I’ve heard that ships are now starting to use medium voltage shore power, I wonder what kind of connections they use.
Surge generator cable fault locators ("thumpers") provide pre-location and pinpoint cable fault location. Cable fault prelocation using ICE (Impulse Current Method) is preferred for extensive underground cable fault location and pinpointing cable faults in water damaged cable joints. Precise location of cable faults through surge generator fault locators (cable thumping) is very quick and limits expensive excavation by pinpoint accuracy.
DC testing has been accepted for many years as the standard field method for performing high-voltage tests on cable insulation systems. Whenever DC testing is performed, full consideration should be given to the fact that steady-state direct voltage creates within the insulation systems an electrical field determined by the geometry and conductance of the insulation, whereas under service conditions, alternating voltage creates an electric field determined chiefly by the geometry and dielectric constant (or capacitance) of the insulation.
Under ideal, homogeneously uniform insulation conditions, the mathematical formulas governing the steady-state stress distribution within the cable insulation are of the same form for DC and for AC, resulting incomparable relative values; however, should the cable insulation contain defects in which either the conductivity or the dielectric constant assume values significantly different from those in the bulk of the insulation,the electric stress distribution obtained with direct voltage will no longer correspond to that obtained with alternating voltage.
Nexans Euromold HV high voltage bushings are suitable for use in oil-insulated high voltage electrical equipment up to 33kV- this includes oil-insulated HV bushings for high voltage transformers, motors, switchgear and capacitors. Nexans Euromold bushings are epoxy insulated in accordance with CENELEC EN 50181. Nexans Euromold plug-in bushings 750S1, 775S1, 775T1 meet the requirements of ANSI/IEEE 386 with 800amp and 1250amp current ratings. Nexans HV bushings are suitable for 5/8" threading systems.
Nexans Euromold Oil-Insulated Epoxy HV High Voltage Bushings
6/10 (12kV)
6.35/11 (12kV)
8.7/15 (17.5kV)
12/20 (24kV)
12.7/22 (24kV)
18/33 (36kV)
Kraus & naimer switch and optional extras kn150 gb0215Dien Ha The
Catalog Kraus Naimer, Catalog,
Catalog Thiết Bị Điện Kraus Naimer, Catalog Thiết Bị Điện,
Catalog Biến Tần Kraus Naimer, Catalog Điện Công Nghiệp,
http://dienhathe.com,
Chi tiết các sản phẩm khác của Kraus Naimer tại https://dienhathe.com
Xem thêm các Catalog khác của Kraus Naimer tại https://dienhathe.info
Để nhận báo giá sản phẩm Kraus Naimer vui lòng gọi: 0907.764.966
Kraus & naimer switch and optional extras kn150 gb0215-dienhathe.vnDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.org
Máy biến áp do tập đoàn LS sản xuất cũng thuộc nhóm sản phẩm cao cấp của thế giới, hiện đang được bán đại trà cho Mỹ, Nhật, Canada, Trung đông, Asia. Các tập đoàn công nghệ hàng đầu như Mitsubishi, Hitachi, Fuji, Siemens,….cũng đang là khách hàng của sản phẩm này trên phạm vi toàn cầu. Hiện LS cũng là một trong những nhà cung cấp Biến thế khô chính của Việt nam với các công trình tiêu biểu như :Royal City, Time City, Nam Á Bank, Air Cargo, Việt Thuận Thành Tower, Lim Tower, Thảo Điền Pearl, Petrovietnam Power Landmark, Petroland Quận 2, Diamond Island, The Era, Royal City, Cresent Mall, Petroland Tower tại Phú Mỹ Hưng, Dragon Hill Residence, Belleza, Khách sạn Continential, Khách sạn Rex, Khách sạn 5 sao Le Meriden, Phú Quốc Airport, Saigon Airport Plaza, Times City, Star City...
Quý khách có nhu cầu mua hàng hoặc hợp tác cùng chúng tôi xin vui lòng liên hệ theo địa chỉ :
CÔNG TY CỔ PHẦN HẠO PHƯƠNG
Trụ sở chính:
Địa chỉ: Số 88 đường Vĩnh Phú 40, Kp. Hòa Long, P. Vĩnh Phú, Thuận An, Bình Dương.
Văn phòng Hà Nội:
Địa chỉ: Số 95 TT4 – KĐT Mỹ Đình Sông Đà – Phường Mỹ Đình – Q. Nam Từ Liêm – Hà Nội
Chi nhánh Cambodia:
Địa chỉ: The Park Land SenSok, Borey Chip Mong, House Number 22, P11.Sangkat Phnom Penh Thmey, Khan San Sok, Phnom Penh.
Email: cs@haophuong.com – Website: haophuong.com
Facebook: https://www.facebook.com/haophuongcompany/
HOTLINE: 1800 6547
Catalog cs switch disconnector_fuse_units_dienhathe.vnDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.vn
Catalog cs switch disconnector_fuse_unitsDien Ha The
Catalog cs switch disconnector_fuse_units
Catalog CS,
Catalog Thiết Bị Điện CS,
Catalog Điện Công Nghiệp CS,
http://dienhathe.com,
Xem thêm các sản phẩm khác của CS tại https://dienhathe.com
Để nhận báo giá sản phẩm CS vui lòng gọi: 0907.764.966
Catalog cs switch disconnector_fuse_units
C&S,
Catalog C&S,
Catalog Thiết Bị Điện C&S,
Catalog Điện Công Nghiệp C&S,
http://dienhathe.com,
Xem thêm các sản phẩm khác của Autonics tại https://dienhathe.com
Để nhận báo giá sản phẩm vui lòng gọi: 0907.764.966
KB Electric may bien ap kho Ls nhap khau KoreaKB ELECTRIC
Chiết khấu cao do KB Electric cung cấp thông tin về nhãn hiệu máy biến áp khô LS nhập khẩu từ Hàn Quốc. Chuyên dùng cho các hệ tòa nhà, cao ốc, bênh viện, trường học, công nghiệp..
Isolation Procedures for Safe Working on Electrical Systems and Equipment by the JIB | solation Procedures for Safe Working on Electrical Systems and Equipment
This chart shows the safe isolation procedure that you should use when working on electrical systems and equipment.
You'll receive a printed copy of this from your Training Provider, but it's also here as a handy reference to keep electronically.
THE RULES OF SAFE ISOLATION ARE:
Obtain permission to start work (a Permit may be required in some situations)
Identify the source(s) of supply using an approved voltage indicator or test lamp
Prove that the approved voltage indicator or test lamp is functioning correctly
Isolate the supply(s)
Secure the isolation
Prove the system/equipment is DEAD using an approved voltage indicator or test lamp
Prove that the approved voltage indicator or test lamp is functioning correctly
Put up warning signs to tell other people that the electrical installation has been isolated
Once the system/equipment is proved DEAD, work can begin
Uploaded by THORNE & DERRICK LV HV Jointing, Earthing, Substation & Electrical Eqpt | Explosive Atmosphere Experts & ATEX IECEx.
THORNE & DERRICK based in the UK are international distributors of LV, MV & HV Cable Installation, Jointing, Substation & Electrical Equipment.
Since 1985, T&D have established an international reputation based on SERVICE | INTEGRITY | TRUST.
Contact us for 3M, ABB, Alroc, AN Wallis, CATU, Cembre, Centriforce, CMP, CSD, Elastimold, Ellis Patents, Emtelle, Euromold, Filoform , Furse, Lucy Electric & Zodion, Nexans, Pfisterer, Polypipe, Prysmian, Roxtec, Sicame, WT Henley.
DevOps and Testing slides at DASA ConnectKari Kakkonen
My and Rik Marselis slides at 30.5.2024 DASA Connect conference. We discuss about what is testing, then what is agile testing and finally what is Testing in DevOps. Finally we had lovely workshop with the participants trying to find out different ways to think about quality and testing in different parts of the DevOps infinity loop.
JMeter webinar - integration with InfluxDB and GrafanaRTTS
Watch this recorded webinar about real-time monitoring of application performance. See how to integrate Apache JMeter, the open-source leader in performance testing, with InfluxDB, the open-source time-series database, and Grafana, the open-source analytics and visualization application.
In this webinar, we will review the benefits of leveraging InfluxDB and Grafana when executing load tests and demonstrate how these tools are used to visualize performance metrics.
Length: 30 minutes
Session Overview
-------------------------------------------
During this webinar, we will cover the following topics while demonstrating the integrations of JMeter, InfluxDB and Grafana:
- What out-of-the-box solutions are available for real-time monitoring JMeter tests?
- What are the benefits of integrating InfluxDB and Grafana into the load testing stack?
- Which features are provided by Grafana?
- Demonstration of InfluxDB and Grafana using a practice web application
To view the webinar recording, go to:
https://www.rttsweb.com/jmeter-integration-webinar
Smart TV Buyer Insights Survey 2024 by 91mobiles.pdf91mobiles
91mobiles recently conducted a Smart TV Buyer Insights Survey in which we asked over 3,000 respondents about the TV they own, aspects they look at on a new TV, and their TV buying preferences.
Software Delivery At the Speed of AI: Inflectra Invests In AI-Powered QualityInflectra
In this insightful webinar, Inflectra explores how artificial intelligence (AI) is transforming software development and testing. Discover how AI-powered tools are revolutionizing every stage of the software development lifecycle (SDLC), from design and prototyping to testing, deployment, and monitoring.
Learn about:
• The Future of Testing: How AI is shifting testing towards verification, analysis, and higher-level skills, while reducing repetitive tasks.
• Test Automation: How AI-powered test case generation, optimization, and self-healing tests are making testing more efficient and effective.
• Visual Testing: Explore the emerging capabilities of AI in visual testing and how it's set to revolutionize UI verification.
• Inflectra's AI Solutions: See demonstrations of Inflectra's cutting-edge AI tools like the ChatGPT plugin and Azure Open AI platform, designed to streamline your testing process.
Whether you're a developer, tester, or QA professional, this webinar will give you valuable insights into how AI is shaping the future of software delivery.
Essentials of Automations: Optimizing FME Workflows with ParametersSafe Software
Are you looking to streamline your workflows and boost your projects’ efficiency? Do you find yourself searching for ways to add flexibility and control over your FME workflows? If so, you’re in the right place.
Join us for an insightful dive into the world of FME parameters, a critical element in optimizing workflow efficiency. This webinar marks the beginning of our three-part “Essentials of Automation” series. This first webinar is designed to equip you with the knowledge and skills to utilize parameters effectively: enhancing the flexibility, maintainability, and user control of your FME projects.
Here’s what you’ll gain:
- Essentials of FME Parameters: Understand the pivotal role of parameters, including Reader/Writer, Transformer, User, and FME Flow categories. Discover how they are the key to unlocking automation and optimization within your workflows.
- Practical Applications in FME Form: Delve into key user parameter types including choice, connections, and file URLs. Allow users to control how a workflow runs, making your workflows more reusable. Learn to import values and deliver the best user experience for your workflows while enhancing accuracy.
- Optimization Strategies in FME Flow: Explore the creation and strategic deployment of parameters in FME Flow, including the use of deployment and geometry parameters, to maximize workflow efficiency.
- Pro Tips for Success: Gain insights on parameterizing connections and leveraging new features like Conditional Visibility for clarity and simplicity.
We’ll wrap up with a glimpse into future webinars, followed by a Q&A session to address your specific questions surrounding this topic.
Don’t miss this opportunity to elevate your FME expertise and drive your projects to new heights of efficiency.
Elevating Tactical DDD Patterns Through Object CalisthenicsDorra BARTAGUIZ
After immersing yourself in the blue book and its red counterpart, attending DDD-focused conferences, and applying tactical patterns, you're left with a crucial question: How do I ensure my design is effective? Tactical patterns within Domain-Driven Design (DDD) serve as guiding principles for creating clear and manageable domain models. However, achieving success with these patterns requires additional guidance. Interestingly, we've observed that a set of constraints initially designed for training purposes remarkably aligns with effective pattern implementation, offering a more ‘mechanical’ approach. Let's explore together how Object Calisthenics can elevate the design of your tactical DDD patterns, offering concrete help for those venturing into DDD for the first time!
Generating a custom Ruby SDK for your web service or Rails API using Smithyg2nightmarescribd
Have you ever wanted a Ruby client API to communicate with your web service? Smithy is a protocol-agnostic language for defining services and SDKs. Smithy Ruby is an implementation of Smithy that generates a Ruby SDK using a Smithy model. In this talk, we will explore Smithy and Smithy Ruby to learn how to generate custom feature-rich SDKs that can communicate with any web service, such as a Rails JSON API.
Connector Corner: Automate dynamic content and events by pushing a buttonDianaGray10
Here is something new! In our next Connector Corner webinar, we will demonstrate how you can use a single workflow to:
Create a campaign using Mailchimp with merge tags/fields
Send an interactive Slack channel message (using buttons)
Have the message received by managers and peers along with a test email for review
But there’s more:
In a second workflow supporting the same use case, you’ll see:
Your campaign sent to target colleagues for approval
If the “Approve” button is clicked, a Jira/Zendesk ticket is created for the marketing design team
But—if the “Reject” button is pushed, colleagues will be alerted via Slack message
Join us to learn more about this new, human-in-the-loop capability, brought to you by Integration Service connectors.
And...
Speakers:
Akshay Agnihotri, Product Manager
Charlie Greenberg, Host
Kubernetes & AI - Beauty and the Beast !?! @KCD Istanbul 2024Tobias Schneck
As AI technology is pushing into IT I was wondering myself, as an “infrastructure container kubernetes guy”, how get this fancy AI technology get managed from an infrastructure operational view? Is it possible to apply our lovely cloud native principals as well? What benefit’s both technologies could bring to each other?
Let me take this questions and provide you a short journey through existing deployment models and use cases for AI software. On practical examples, we discuss what cloud/on-premise strategy we may need for applying it to our own infrastructure to get it to work from an enterprise perspective. I want to give an overview about infrastructure requirements and technologies, what could be beneficial or limiting your AI use cases in an enterprise environment. An interactive Demo will give you some insides, what approaches I got already working for real.
Builder.ai Founder Sachin Dev Duggal's Strategic Approach to Create an Innova...Ramesh Iyer
In today's fast-changing business world, Companies that adapt and embrace new ideas often need help to keep up with the competition. However, fostering a culture of innovation takes much work. It takes vision, leadership and willingness to take risks in the right proportion. Sachin Dev Duggal, co-founder of Builder.ai, has perfected the art of this balance, creating a company culture where creativity and growth are nurtured at each stage.
UiPath Test Automation using UiPath Test Suite series, part 4DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 4. In this session, we will cover Test Manager overview along with SAP heatmap.
The UiPath Test Manager overview with SAP heatmap webinar offers a concise yet comprehensive exploration of the role of a Test Manager within SAP environments, coupled with the utilization of heatmaps for effective testing strategies.
Participants will gain insights into the responsibilities, challenges, and best practices associated with test management in SAP projects. Additionally, the webinar delves into the significance of heatmaps as a visual aid for identifying testing priorities, areas of risk, and resource allocation within SAP landscapes. Through this session, attendees can expect to enhance their understanding of test management principles while learning practical approaches to optimize testing processes in SAP environments using heatmap visualization techniques
What will you get from this session?
1. Insights into SAP testing best practices
2. Heatmap utilization for testing
3. Optimization of testing processes
4. Demo
Topics covered:
Execution from the test manager
Orchestrator execution result
Defect reporting
SAP heatmap example with demo
Speaker:
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
Neuro-symbolic is not enough, we need neuro-*semantic*Frank van Harmelen
Neuro-symbolic (NeSy) AI is on the rise. However, simply machine learning on just any symbolic structure is not sufficient to really harvest the gains of NeSy. These will only be gained when the symbolic structures have an actual semantics. I give an operational definition of semantics as “predictable inference”.
All of this illustrated with link prediction over knowledge graphs, but the argument is general.
Accelerate your Kubernetes clusters with Varnish CachingThijs Feryn
A presentation about the usage and availability of Varnish on Kubernetes. This talk explores the capabilities of Varnish caching and shows how to use the Varnish Helm chart to deploy it to Kubernetes.
This presentation was delivered at K8SUG Singapore. See https://feryn.eu/presentations/accelerate-your-kubernetes-clusters-with-varnish-caching-k8sug-singapore-28-2024 for more details.
Designing Great Products: The Power of Design and Leadership by Chief Designe...
Elastimold Connectors - Loadbreak & Deadbreak Elbow & Bolted Tee Connectors - HV MV - 600 Series
1. Power & High Voltage — Elastimold® Underground Cable Accessories
Tel: +44 (0)191 490 1547
Fax: +44 (0)191 477 5371
Email: northernsales@thorneandderrick.co.uk
Website: www.cablejoints.co.uk
www.thorneanderrick.co.uk
600-Amp Elbow Connectors
600 Series Deadbreak
Components
600 Series deadbreak elbows, straight receptacles, junctions, vault
stretchers and accessories are used to connect equipment and cable
on primary feeder and network circuits. Designs accommodate large
conductors and feature bolted connections and deadfront modular
construction for maximum reliability, performance and versatility.
De-energized connectors can be quickly and easily connected and
disconnected using standard hand tools and equipment in accordance
with accepted operating practices. Optional accessories allow visible
external separation, bypass, isolation, dead-ending, grounding and
testing as well as adding taps, surge arresters and circuit protection.
Hotstick-operable and separable joint systems are shown on
pages H-14–H-17 and H-23–H-24.
Ratings Overview
See page H-2 for complete information.
Current Ratings
(Prefixes: 650, K650, K651, K655,
K656, 750, 755, 756 & 03700)
Separable Connectors 600 Series Deadbreak
STRAIGHT RECEPTACLE
See pages H-46–H-52
for surge arrester
applications
STRAIGHT
RECEPTACLE ADAPTER
900 Amp Continuous
25kA sym., 10 cycles
INTEGRAL
BUSHING
BUSHING
EXTENDER
CONNECTING
PLUG
SEE PAGES H-20–H-21 FOR
ADDITIONAL JUNCTIONS
CONNECTING
PLUG
†
600 SERIES
TAPS
†
LOADBREAK
ELBOW TAP
PLUG
2 PT JUNCTION
3 PT JUNCTION
Voltage Ratings
15/25kV Class (5kV thru 28kV)
16.2kV Phase-to-Ground
28kV Phase-to Phase
140kV BIL
45kV AC Withstand
84kV DC Withstand
21.5kV Corona Extinction
35kV Class
21.1kV Phase-to-Ground
36.6kV Phase-to-Phase
150kV BIL
50kV AC Withstand
103kV DC Withstand
26kV Corona Extinction
Note: Elastimold has increased the IEEE
Standard Production and Design Test levels
for 25kV Class products to include 27kV
and 28kV systems.
4 PT JUNCTION
BUSHING
EXTENDER
INSULATED
CAP WITH
TEST POINT
GROUNDING PLUG
CABLE
ADAPTER
INSULATED
PARKING BUSHING
HOTSTICK OPERABLE 600 SERIES
CONNECTORS - SEE PAGES H-14–H-17
THREADED
COMPRESSION LUG
STICK-OP LOADBREAK
REDUCING TAP PLUG
STICK-OP
SEE PAGES
H-16–H-17
CABLE TO CABLE
UTILIZING L-KITS
SEE PAGES H-12–H-13
COMPRESSION
LUG
VAULT
STRETCHER
CONNECTOR
THREADED
STUD
VAULT
STRETCHER
CAM-OP
RETAINER
SLEEVES
CAM-OP
SEE PAGES
H-14–H-15
CAM-OP
LINK CONNECTOR
COMPRESSION
LUG
CABLE
ADAPTER
* Tested at 8.3/14.9kV
†
Tested at 15.2/26.3kV
H-10
THREADED
STUD
OPERATING
ACCESSORIES
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
200A DEADBREAK
SEE PAGES H-8–H-9
DEADBREAK
REDUCING TAP
PLUG
REDUCING
TAP WELL
COMPRESSION
LUG
CABLE
ADAPTER
Note: 900-amp ratings require copper cable
and copper current-carrying components.
CABLE
ADAPTER
200A TAPS
INSULATED VOLTAGE
DETECTION
PLUG
CAP
600 SERIES
ELBOW
CABLE TO CABLE
(UTILIZING JUNCTIONS)
COMPRESSION
LUG
ELBOW CONNECTOR
THREADED
STUD
THREADED
STUD
RETAINING
RING
STRAIGHT
RECEPTACLE HOUSING
CABLE TO EQUIPMENT
600 Amp Continuous
25kA sym., 10 cycles
(Prefixes 675, K671, K675, K676,
775, 776 & 03702)
BOLT &
WASHER
CABLE TO CABLE UTILIZING
VAULT STRETCHERS
SEE PAGES H-12–H-13
www.tnb.com
SPANNER WRENCH
200A LOADBREAK
SEE PAGES H-4–H-5
TEST AND GROUND
SEE PAGES H-16–H-17
2. 600-Amp Elbow Connectors
DESCRIPTION
VOLTAGE
CLASS
600 Series Elbow
15/25kV
(w/ Insul. Plug, Cap, Stud,
Lug and Cable Adapter)
35kV
CAT. NO.
K655LR-W0X
ILLUSTRATION
(NOT TO SCALE)
755LR-W0X
15/25kV K655DLR-W0X
(w/ Insul. Plug, Cap,
Stud Lug and Cable Adapter)
35kV
600 Series Elbow
15/25kV
w/ Test Point (w/ Insul. Plug,
Cap, Stud, Lug and Cable Adapter)
Use Tables W7 and X6
755DLR-W0X
35kV
K656LR-W0X
756LR-W0X
15/25kV K656DLR-W0X
(w/ Insul. Plug, Cap, Stud, Lug
and Cable Adapter)
35kV
600 Series Elbow
15/25kV
w/ Test Point Housing only (w/ Stud)
600 Series Elbow
w/ Test Point Housing only (w/ Stud)
600 Series
Replacement Elbow
Use Tables W7 and X6
756DLR-W0X
N1, 2
N1, 2, 12
N1, 2, 12
15/25kV
K655BLR
755BLR
K656BLR
756BLR
K655BRLR
N1, 3
N1, 3
N1, 3
N1, 3
N14
15/25kV
K656BRLR
N14
15/25kV K655SR-W0X
N1, 2, 11
(w/ Cable Adapter, Lug & Retaining Ring)
15/25kV K655DSR-W0X N1, 2, 11, 12
600 Series Direct
Use Tables W7 and X6
Test Straight Receptacle Elbow
600 Series Straight
15/25kV
K655BSR
N1,11
Receptacle Housing
(Lug & Cable Adapter not included)
Straight Receptacle Adapter 15/25kV
K650SRA
N1, 4
600 Series Vault Stretcher
K655BVS
755BVS
N1, 9
N1, 9
15/25kV
35kV
Cable Size Adapter
15/25kV
35kV
All
All
(Cable Adapter & Lug)
15/25kV
35kV
ALL
N7, 8
N7, 8
15/25kV
35kV
K651CP
750CP
N1, 7, 8, 10
N1, 7, 8, 10
15/25kV
K650RTP
N1, 7, 8, 9
15/25kV
K650RTW
N1, 7, 8, 9
15kV
25kV
35kV
15/25kV
35kV
15/25kV
35kV
650ETP
K650ETP
750ETP
650VSA
750VSA
N1, 7, 8, 10
N1, 7, 8, 10
N1, 7, 8, 10
N1
N1
N1
N1
All
600ATM
All
600SW
N9
200TC-1
N12
All
200TC-2
200TC-4
N12
N12
650SA
750SA
Add suffix symbol from page H-41 to include cable shield grounding kit and/or cable jacket sealing kit.
Available without the stud by adding “N” to the catalog number.
N4.
755CA-W
For 900-amp ratings, substitute 675 for 650 and 655; 676 for 656; K671 for K651; K675
for K650 and K655; K676 for K656; 775 for 750 and 755; 776 for 756 and 2X for 0X in the catalog
number. The 900-amp rating requires copper current-carrying connector components
and copper conductor cable.
N3.
03700X
N5
Use Table X6
03702X
N6
655CK-W0X
N2
Use Tables W7 and X6
755CK-W0X
N2
Use Tables W9 and X6
Adapter Retaining Ring
K650SOP
750SOP
N2.
655CA-W
Use Table W7
Use Table X6
600 Series Elbow & Vault
Stretcher Size Sensitive Kit
15/25kV
35kV
N1.
Straight Receptacle Adapter is used to connect Straight Receptacles K655YBSR and K655YSR-W0X
(page H-24) to equipment bushings.
N5.
Aluminum lug for use on aluminum or copper conductors. DO NOT substitute threaded 03600X lug.
N6.
Copper lug for use on COPPER CONDUCTOR ONLY. Do not substitute threaded 03602X lug.
N7.
Available with the stud factory-assembled by adding “SP” to the catalog number. 675ETP, K675ETP
and 775ETP are available as -SP only. The stud is not field removable.
N8.
Available with a loose stud by adding suffix “S” to the catalog number.
N9.
600SW spanner wrench is recommended for installation of deadbreak reducing tap plugs and
reducing tap wells.
Use Table W9
Compression Lug
N1, 7, 8
N1, 7, 8
Vault Stretcher
Threaded Stud
600 Series Elbow
Threaded Stud
Assembly Tool
(Window-OP)
Use Tables W7 and X6
(Housing only w/ Stud)
650GP
750GP
Loadbreak Elbow
Tap Plug
Housing only w/ Test Point
600 Series
Straight Receptacle
15/25kV
35kV
N1, 2
Housing only w/o Test Point
600 Series
Replacement Elbow
N1, 7, 8
N1, 7, 8
Spanner Wrench
N1, 2, 12
Use Tables W9 and X6
35kV
15/25kV
35kV
K650BIP
750BIP
Direct Voltage Test
Meter Adapter for:
HD Electric Meters
Ross Meters
Chance Meters
N1, 2, 12
Use Tables W9 and X6
600 Series Direct
Test Elbow w/Test Point
15/25kV
35kV
Reducing Tap Well
N1, 2
Use Tables W9 and X6
Use Tables W7 and X6
NOTES
DESCRIPTION
Insulating Plug
(w/Cap)
Grounding Plug
(Ground Lead 2/0
AWG x 30")
Insulated Parking
Bushing
Use Tables W9 and X6
600 Series Direct
Test Elbow
CAT. NO.
Deadbreak Reducing
Tap Plug
N1, 2
Use Tables W7 and X6
VOLTAGE
CLASS
Connecting Plug
NOTES
N10. Use 600ATM Assembly Tool.
650ARR-X
Use Table X6
15/25kV 655CK-W0X-ARR
600 Series Straight
Receptacle Size Sensitive Kit
Use Tables W7 and X6
(Cable Adapter, Retaining Ring & Lug)
Power & High Voltage — Elastimold® Underground Cable Accessories
ILLUSTRATION
(NOT TO SCALE)
N2
N11. 600 Series Elbows and Straight Receptacles with IEEE Std. 386 capacitive test points are available by
substituting 656 for 655; K656 for K655; K676 for K675; 756 for 755; 676 for 675; K676 for K675
and 776 for 775 in the catalog number.
N12. Direct Test Connectors, along with a 200TC-X series meter adapter, a properly rated voltage meter
and Hot-line Stick; provides a means for direct conductor voltage testing.
15/25kV
35kV
K655BE
755BE
N1, 3
N1, 3
Insulated Cap w/ Test Point 15/25kV
K656DR
K656DRG
N13. With stainless steel bracket.
N3, 7
N3, 7
Bushing Extender
(w/ Stud)
N14. Replacement Elbow includes an I-Adapter, and Straight Receptacle, resulting in a net gain of 20".
(w/ Stud)
Insulated Cap w/ Test Point 15/25kV
(w/ Stud)
www.tnb.com
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Refer to the W and X tables on page H-45 for sizing to cable insulation diameter
and conductor size. For cable shield adapters and jacket seals, see page H-37.
Technical Services
Tel: 888.862.3289
H-11
3. Power & High Voltage — Elastimold® Underground Cable Accessories
600-Amp Elbow Connectors
600 Series Deadbreak
Components (continued)
600 Series deadbreak elbows, straight receptacles, junctions,
vault stretchers and accessories are used to connect equipment and
cable on primary feeder and network circuits. Designs accommodate
large conductors and feature bolted connections and deadfront modular
construction for maximum reliability, performance and versatility.
De-energized connectors can be quickly and easily connected and
disconnected using standard hand tools and equipment in accordance
with accepted operating practices. Optional accessories allow visible
external separation, bypass, isolation, dead-ending, grounding and
testing as well as adding taps, surge arresters and circuit protection.
Hotstick operable and separable joint systems are shown on pages
H-14–H-17 and H-23–H-24.
Ratings Overview
See page H–2 for complete
information.
Separable Connectors 600 Series Deadbreak
See pages H-46–H-52
for surge arrester
applications
STRAIGHT RECEPTACLE
Current Ratings
STRAIGHT
RECEPTACLE ADAPTER
(Prefixes: 650, K650, K651, K655,
K656, 750, 755, 756 & 03700)
600 Amp Continuous
25kA sym., 10 cycles
(Prefixes 675, K675, K671, K676,
775, 776 & 03702)
900-amp Continuous
25kA sym., 10 cycles
Note: 900-amp ratings require copper cable
and copper current-carrying components.
INTEGRAL
BUSHING
BUSHING
EXTENDER
35kV Class
21.1kV Phase-to-Ground
36.6kV Phase-to-Phase
150kV BIL
50kV AC Withstand
103kV DC Withstand
26kV Corona Extinction
Note: Elastimold has increased the IEEE
Standard Production and Design Test levels
for 25kV Class products to include 27kV
and 28kV systems.
†
600 SERIES
TAPS
200A DEADBREAK
SEE PAGES H-8–H-9
DEADBREAK
REDUCING TAP
PLUG
†
†
REDUCING
TAP WELL
†
COMPRESSION
LUG
LOADBREAK
ELBOW TAP
PLUG
CABLE
ADAPTER
SPANNER WRENCH
200A LOADBREAK
SEE PAGES H-4–H-5
TEST AND GROUND
TEST AND GROUND
SEE PAGES H-16–H-17
2-PT JUNCTION
3-PT JUNCTION
L-4
4-PT JUNCTION
THREADED
STUD
BUSHING
EXTENDER
OPERATING
ACCESSORIES
L-3
INSULATED
CAP WITH
TEST POINT
GROUNDING PLUG
CABLE
ADAPTER
INSULATED
PARKING BUSHING
HOTSTICK OPERABLE 600 SERIES
CONNECTORS - SEE PAGES H-14–H-17
STICK-OP
THREADED
COMPRESSION LUG
STICK-OP LOADBREAK
REDUCING TAP PLUG
SEE PAGES
H-16–H-17
L-2
CABLE TO CABLE
UTILIZING L-KITS
L-1
COMPRESSION
LUG
VAULT
STRETCHER
CONNECTOR
VS2
THREADED
STUD
VS3
VAULT
STRETCHER
CAM-OP
RETAINER
SLEEVES
CAM-OP
CAM-OP
LINK CONNECTOR
* Tested @ 8.3/14.9kV
†
Tested @ 15.2/26.3kV
Tested @ 21.1/36.6kV
H-12
CONNECTING
PLUG
CONNECTING
PLUG
CABLE
ADAPTER
200A TAPS
INSULATED VOLTAGE
DETECTION
PLUG
CAP
600 SERIES
ELBOW
Voltage Ratings
15/25kV Class (5kV thru 28kV)
16.2kV Phase-to-Ground
28kV Phase-to-Phase
140kV BIL
45kV AC Withstand
84kV DC Withstand
21.5kV Corona Extinction
COMPRESSION
LUG
ELBOW CONNECTOR
THREADED
STUD
CABLE TO CABLE
(UTILIZING JUNCTIONS)
RETAINING
RING
STRAIGHT
RECEPTACLE HOUSING
CABLE TO EQUIPMENT
THREADED
STUD
BOLT &
WASHER
SEE PAGES
H-14–H-15
COMPRESSION
LUG
CABLE TO CABLE UTILIZING
VAULT STRETCHERS
CABLE
ADAPTER
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
www.tnb.com
VS4
4. 600-Amp Elbow Connectors
VOLTAGE
CLASS
CAT. NO.
NOTES
1-Way
L-Kit
2-Way
15/25kV
35kV
15/25kV
35kV
15/25kV
35kV
15/25kV
35kV
15/25kV
K650J2
750J2
K650J3
750J3
K650J4
750J4
K655L1
755L1
K655L2
L-Kit
35kV
755L2
2-Way
VS-Kit
3-Way
L-Kit
3-Way
VS Kit
4-Way
L-Kit
4-Way
VS-Kit
Assembly Tool
15/25kV
35kV
15/25kV
35kV
15/25kV
35kV
15/25kV
35kV
15/25kV
35kV
ALL
K655VSL2
755VSL2
K655L3
755L3
K655VSL3
755VSL3
K655L4
755L4
K655VSL4
755VSL4
600ATM
N1, 7, 8
N1, 7, 8
N1, 7, 8
N1, 7, 8
N1, 7, 8
N1, 7, 8
N1, 2, 3
N1, 2, 3
N1,2 ,3, 4,
5, 6
N1, 2, 3, 4,
5, 6
N1, 2, 3
N1, 2, 3
N1, 2, 3, 4
N1, 2, 3, 4
N1, 2, 3, 5, 6
N1, 2, 3, 5, 6
N1, 2, 3, 4
N1, 2, 3, 4
N1, 2, 3, 5, 6
N1, 2, 3, 5, 6
—
DESCRIPTION
2-Point Junction
3-Point Junction
4-Point Junction
www.tnb.com
N1. For 900-amp ratings, substitute 675 for 650 and 655; 676 for 656;
K675 for K650 and K655; K676 for K656; 775 for 750 and 755; 776
for 756 and 2X for 0X in the catalog number. The 900-amp rating
requires copper current-carrying connector components and
copper conductor cable.
N2. L-Kits and VS-Kits do not include cable adapters or compression lugs.
These items must be ordered separately.
N3. 600 Series Elbows and Straight Receptacles with IEEE Std. 386
capacitive test points are available by substituting 656 for 655; K656
for K655; K676 for K675; 756 for 755; 676 for 675; K676 for K675
and 776 for 775 in the catalog number.
N4. 600ATM is recommended for installing K651CP and 750CP.
N5. Can be used as a repair joint. (Gains 31⁄2" of repair length.)
N6. Can be used as a reducing joint for different size cables.
N7. Rubber junction with stainless steel mounting plate and back plate.
Add “-U” for rubber junction with stainless steel mounting plate,
back plate and adjustable mounting bracket.
Add “-4” for rubber junction only.
Add “-5” for rubber junction, stainless steel U-straps and back plate.
N8. Two - six-position multi-point junctions shown on pages H-25–H-26.
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
Power & High Voltage — Elastimold® Underground Cable Accessories
ILLUSTRATION
(NOT TO SCALE)
H-13
5. Power & High Voltage — Elastimold® Underground Cable Accessories
600-Amp Elbow Connectors
600 Series Cam-Op
Deadbreak Connector System
™
Elastimold’s 600 Series Cam-Op™ deadbreak connector system
incorporates provisions for hotstick operation of de-energized
primary feeder or network circuits. Configurations allow external
visible break, testing, grounding and isolation. Retrofit kits allow
upgrading existing equipment.
The Cam-Op system utilizes pin and socket connectors and can
be retrofitted to existing equipment. The Cam-Op connector is
easily installed or removed by hotstick operation of the cam action
disconnect lever.
Ratings Overview
See page H-2 for complete information.
Cam-Op™ System — 600 Series Deadbreak
EQUIPMENT
BUSHING
Current Ratings
600 & 900 Amp Continuous
25kA sym., 10 cycles
Note: 900-amp ratings require copper cable
and copper current-carrying components.
CAM-OP
INSULATED
PARKING BUSHING
CABLE TO EQUIPMENT
ALIGNMENT
BUSING
CAM-OP
MOUNTED INSULATED
PARKING BUSHING
INSULATED
CAP
600 SERIES
ELBOW
COMPRESSION
LUG
SEE CABLE NOTES
CAM-OP
CABLE
ADAPTER
CABLE
ADAPTER
LOADBREAK ELBOW
CONNECTOR
R
SEE CABLE NOTES
ELASTIMOLD
H-14
RETAINER
SLEEVES
ELASTIMOLD
35kV Class
21.1kV Phase-to-Ground
36.6kV Phase-to-Phase
150kV BIL
50kV AC Withstand
103kV DC Withstand
26kV Corona Extinction
BUSHING
EXTENDER
R
25kV Class
15.2kV Phase-to-Ground
26.3kV Phase-to-Phase
125kV BIL
40kV AC Withstand
78kV DC Withstand
19kV Corona Extinction
RETROFIT COMPONENTS FOR
EXISITING EQUIPMENT W/O
PROVISIONS FOR MOUNTABLE
INSULATED BUSHING
EQUIPMENT
BUSHING
Continuous
Voltage Ratings
15kV Class
8.3kV Phase-to-Ground
14.4kV Phase-to-Phase
95kV BIL
34kV AC Withstand
53kV DC Withstand
11kV Corona Extinction
ALIGNMENT
BRACKET
VISI LINK
COMPRESSION
LUG
TEST ROD
600 SERIES
ELBOW
CAM-OP
GROUNDING
ELBOW
RETAINER
SLEEVES
BI-SOP
2-POINT INSULATED
BUSHINGS
600 SERIES
ELBOW
COMPRESSION
LUG
CABLE TO CABLE CONNECTION
CABLE
ADAPTER
SEE CABLE NOTES
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
www.tnb.com
ELBOW
ARRESTER
6. 600-Amp Elbow Connectors
15kV
Cam-Op
Connector Kit
Mountable
Insulated
Bushing
25kV
35kV
25kV
35kV
15kV
Retrofit
Cam-Op
Connector Kit
25kV
35kV
CAT. NO.
NOTES
655LINK-C-LR-W0X-B-DRG N1, 2, 8, 10, 11, 12
Use Tables W7 and X6
K655LINK-C-LR-W0X-B-DRG N1, 2, 8, 10, 11, 12
Use Tables W7 and X6
755LINK-C-LR-W0X-B-DRG N1, 2, 8, 10, 11, 12
Use Tables W9 and X6
K650LBM-3
750LBM-3
N2
N2
655LINK-C-LR-W0X-A-DRG N4, 8, 10, 11, 12
Use Tables W7 and X6
K655LINK-C-LR-W0X-A-DRG N4, 8, 10, 11, 12
Use Tables W7 and X6
755LINK-C-LR-W0X-A-DRG N4, 8, 10, 11, 12
Use Tables W9 and X6
Insulating
Plug
25kV
35kV
K650LB
750LB
N3
N3
Cam-Op
Alignment
Bracket
15kV
25kV
35kV
650CAB
K650CAB
750CAB
—
All
03700X
Use Table X6
03702X
Use Table X6
N5
Compression
Lug
655CK-W0X
Use Tables W7 and X6
755CK-W0X
Use Tables W9 and X6
N10
650RSC
N8
Cam-Op Size
Sensitive Kit
(Cable Adapter
& Lug)
Cam-Op
Retaining
Sleeve
All
15kV
Cam-Op Cable
Joint Kit
Cam-Op
Loadbreak
Reducing Tap
Plugs
25kV
35kV
N1. Cam-Op connector kit includes: (1) Cam-Op link; (1) elbow
housing; (1) cable adapter; (1) 0370 style lug; (1) bushing
extender; (2) retainer sleeves; (1) insulated cap; (1) mountable
insulated bushing and (1) alignment bracket.
N2. Mountable insulated bushing included with Cam-Op
connector kit. Requires three threaded studs on equipment
faceplate for installation.
N3. Use with the Retrofit Cam-Op connector kit.
N4. Retrofit Cam-Op connector kit includes: (1) link; (1) elbow housing;
(1) cable adapter; (1) 0370 style lug; (1) bushing extender; (2)
retainer sleeves; (1) insulated cap; (1) insulating plug; and (1)
alignment bracket.
N5. Aluminum lug for use on aluminum or copper conductors.
DO NOT substitute threaded 03600X lug.
N6. Copper lug for use on COPPER CONDUCTOR ONLY.
DO NOT substitute 03602X threaded lug.
N7. Cam-Op Cable Joint Kit includes: (1) Cam-Op link; (1) Cam-Op
BI-SOP; (2) elbow housings; (2) cable adapters; (2) 0370 style
lugs; (2) retainer sleeves; (1) insulated cap.
N8. 600ATM is recommended for installing Cam-Op retaining sleeves.
N6
N10
655BI-LINK-C-LR-WOX-DRG N7, 8, 10, 11, 12
Use Tables W7 and X6
K655BI-LINK-C-LR-WOX-DRG N7, 8, 10, 11, 12
Use Tables W7 and X6
755BI-LINK-C-LR-WOX-DRG N7, 8, 10, 11, 12
Use Tables W9 and X6
15kV
25kV
35kV
650LK-C-VB
K650LK-C-VB
750LK-C-VB
650LK-C
K650LK-C
750LK-C
(1/0 AWG x 6’
Ground Lead)
160GLR
370GLR
370GLR
N 13
N 13
Test Rod
All
370TR
—
N11. To add elbows or arresters instead of insulating caps, replace
the “DRG” with “LR-WX” for elbows (with test point) or “ESA”
for elbow arresters.
N12. 600 Series Elbows with IEEE 386 capacitive test points are
available by substituting 656 for 655; K656 for K655; K676 for
K675; 756 for 755; 676 for 675; K676 for K675 and 776 for
775 in the catalog number.
N13. Rated for both 25kV and 35kV applications.
—
15kV
25kV
35kV
N10. Add suffix symbol from page H-38 to include cable shield
grounding kit and/or cable jacket sealing kit.
—
15kV
25kV
35kV
N9. For 900-amp ratings, substitute 675 for 650 and 655; 676 for
656; K675 for K650 and K655; K676 for K656; 775 for 750 and
755; 776 for 756 and 2X for 0X in the catalog number. The 900amp rating requires copper current-carrying connector components
and copper conductor cable.
Power & High Voltage — Elastimold® Underground Cable Accessories
ILLUSTRATION
VOLTAGE
(NOT TO SCALE) DESCRIPTION CLASS
(Visi-Break)
Cam-Op Link
Grounding
Elbow
www.tnb.com
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Refer to the W and X tables on page H-45 for sizing to cable insulation
diameter and conductor size. For cable shield adapters and jacket seals,
see page H-37.
Technical Services
Tel: 888.862.3289
H-15
7. Power & High Voltage — Elastimold® Underground Cable Accessories
600-Amp Elbow Connectors
600 Series Test and Ground and Stick-Op —
Deadbreak Connector Systems
™
Elastimold’s 600 Series Test and Ground and StickOp™ deadbreak connector systems incorporate
provisions for hotstick operation of de-energized
primary feeder or network circuits.
The Test and Ground and Stick-Op connectors allow
direct testing and grounding with no required cable
movement.
Test and Ground is ideal for equipment applications
which include viewing windows to provide an internal
visible break that does not require hotstick removal
of the elbows.
Stick-Op provides an external visible break by
hotstick removal of the elbow.
Test and Ground and Stick-Op connectors are bolted
and installed using torque-controlled tools.
Ratings Overview
See page H-2 for complete information.
Current Ratings
600 & 900-amp Continuous
25kA sym., 10 cycles
Stick-Op™ & Test and Ground System — 600 Series Deadbreak
See pages H-46–H-52
for surge arrester
applications
STICK-OP LRTP
LOADBREAK
TAP PLUG
INTEGRAL
BUSHING
Note: 900-amp ratings require copper cable
and copper current-carrying components.
25kV Class
15.2kV Phase-to-Ground
26.3kV Phase-to-Phase
125kV BIL
40kV AC Withstand
78kV DC Withstand
19kV Corona Extinction
TEST AND GROUND ETP
ELBOW TAP PLUG
THREADED
COMPRESSION LUG
STICK-OP
OR
COMPRESSION LUG
TEST AND GROUND
Continuous
Voltage Ratings
15kV Class
8.3kV Phase-to-Ground
14.4kV Phase-to-Phase
95kV BIL
34kV AC Withstand
53kV DC Withstand
11kV Corona Extinction
INSULATED CAP
600 SERIES
ELBOW
CABLE
ADAPTER
SEE CABLE NOTES
TEST ROD
STAND-OFF
PLUG
ASSEMBLY TOOL
(TEST AND GROUND)
ASSEMBLY TOOL
(STICK-OP)
GROUNDING
ELBOW
STICK-OP
600DB/200LB
BUSHING ELBOW
ADAPTER
GROUNDING
PLUG
OPERATING ACCESSORIES
35kV Class
21.1kV Phase-to-Ground
36.6kV Phase-to-Phase
150kV BIL
50kV AC Withstand
103kV DC Withstand
26kV Corona Extinction
H-16
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
www.tnb.com
8. 600-Amp Elbow Connectors
DESCRIPTION
Test and Ground
Connector Kit
VOLTAGE
CLASS
15kV
25kV
35kV
Test and Ground
Replacement
Connector Kit
Stick-Op
Connector Kit
15kV
25kV
15kV
25kV
35kV
CAT. NO.
NOTES
655ETP-W0X-DRG N1, 4, 5, 6,
Use Tables W7 and X6
11, 13
K655ETP-W0X-DRG
Use Tables W7 and X6
755ETP-W0X-DRG
Use Tables W9 and X6
655RETP
N4, 5, 6, 11,
13, 14
K655RETP
655LRTP-W0X-DRG N2, 3, 4, 5,
Use Tables W7 and X6
8, 11
K655LRTP-W0X-DRG
Use Tables W7 and X6
755LRTP-W0X-DRG
Use Tables W9 and X6
655RLRTP
N3, 4, 5,
8, 11, 14
K655RLRTP
Stick-Op
Replacement
Connector Kit
15kV
Test and Ground
Loadbreak Elbow
Tap Plug
Stick-Op
Loadbreak
Reducing
Tap Plug
Stick-Op
Bushing
Adapter
Compression Lug
Test and Ground
15kV
25kV
35kV
15kV
25kV
35kV
650ETP
K650ETP
750ETP
650LRTPA3
K650LRTPA2
750LRTPA2
N4, 13
N4, 13
N4, 13
N3, 4
15kV
25kV
35kV
All
N3, 4
All
15kV
25kV
35kV
655BEA3
K655BEA2
755BEA2
03700X
Use Tables X6
03702X
Use Tables X6
03600X
Use Tables X6
03602X
Use Tables X6
655CK-W0X
Use Tables W7 and X6
755CK-W0X
Use Tables W9 and X6
655TCK-W0X
Use Tables W7 and X6
755TCK-W0X
Use Tables W9 and X6
650ET
160GLR
370GLR
370GLR
All
All
370TR
600AT
—
N3
All
600ATM
N13
25kV
All
Threaded
Compression
Lug
Stick-Op
Test and Ground
Size Sensitive Kit
(Cable Adapter
& Lug)
Stick-Op
Size Sensitive Kit
(Cable Adapter
& Threaded Lug)
Extraction Tool
Grounding
Elbow
(1/0 AWG x 6'
Ground Lead)
Test Rod
Assembly Tool
(Stick-Op)
Assembly Tool
(Test and Ground)
All
All
15/25kV
35kV
15/25kV
35kV
N6
N7
N1. Test and Ground Kit includes: insulated cap; Test and Ground
reducing tap plug; 600 Series elbow housing; cable adapter;
and 0370 style compression lug.
N2. Stick-Op Kit includes insulated cap; Stick-Op Loadbreak reducing
tap plug; 600 Series Elbow Housing; cable adapter; and threaded
0360 style compression lug.
N3. 600AT assembly tool required for operation and/or installation
of Stick-Op.
N4. For 900-amp ratings, substitute 675 for 650 and 655; 676
for 656; K675 for K650 and K655; K676 for K656; 775 for 750
and 755; 776 for 756 and 2X for 0X in the catalog number.
The 900-amp rating requires copper current-carrying connector
components and copper conductor cable.
N5. Add suffix symbol from page H-38 to include cable shield
grounding kit and/or cable jacket sealing kit.
N6. Aluminum lug for use on aluminum or copper conductors.
DO NOT substitute threaded 03600X lug.
N7. Copper lug for use on COPPER CONDUCTOR ONLY.
DO NOT substitute 03602X threaded lug.
N8. Threaded aluminum lug (Stick-Op only) for use on copper or
aluminum conductors. DO NOT substitute unthreaded 03700X
lugs. DO NOT use with 675, 676, K675, K676, 775 or 776
catalog numbers.
N9. Threaded copper lug (Stick-Op only) for use on copper conductors
only. DO NOT substitute unthreaded 03702X lugs.
N10. Required to disassemble Stick-Op loadbreak reducing tap plug
from the threaded compression lug and 600 Series elbow after
the shear-pin is broken during assembly.
N11. 600 Series Elbows with IEEE 386 capacitive test points are
available by substituting 656 for 655; K656 for K655; K676 for
K675; 756 for 755; 676 for 675; K676 for K675 and 776 for
775 in the catalog number.
Power & High Voltage — Elastimold® Underground Cable Accessories
ILLUSTRATION
(NOT TO SCALE)
N12. Rated for both 25kV and 35kV applications.
N8, 15
N13. 600ATM assembly tool required for Test and Ground assembly.
50–60 ft./lbs. torque wrench required but not included.
N9
N14. Replacement Elbow includes: insulated cap; reducing tap
plug; 600 series elbow housing; I-Adapter; straight receptacle,
resulting in a net gain of 20" in length vs. a standard elbow kit.
Compression lugs and cable adapters are ordered separately.
N5
N5
N5
N15. Retrofit sleeve to convert 03600X Series lug to a 03700X Series
lug (catalog number 650-353).
N5
N10
N12
N12
Refer to the W and X tables on page H-45 for sizing to cable insulation
diameter and conductor size.For cable shield adapters and jacket seals,
see page H-37.
Tel: +44 (0)191 490 1547
www.tnb.com
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services+44 (0)191 477 5371
Fax:
Tel: 888.862.3289 northernsales@thorneandderrick.co.uk
Email:
H-17
Website: www.cablejoints.co.uk