2. Our profile
Since its establishment in 1998, BPA GmbH has grown to become the technical standard bearer
in the fields of structural waterproofing, construction joint sealing, tunnel sealing and
the refurbishment of concrete structures.
Through innovative system-based solutions, numerous product patents, independent product
accreditations, high-quality products, and our friendly and skilled technical advice,
BPA has become a Global Leader in the provision of innovative Structural Waterproofing and
Sealing Systems with many prestigious job references worldwide. "Waterproofing is our Passion!"
Specification services
We provide our specification services to Architects, Engineers,
Tunnel Builders and Specifiers throughout the design and
documentation stages. BPA can provide ongoing support
to the completion of your project through our international
network and partners around the world.
Our Services:
• Product - Application and Site Support
• Product Documentation and Samples
•
•
• Continuing Professional Development seminars
• Contractor Support - economical site solutions
• Advice on Quality requirements & documentation
Innovative and successful
over a long number
of years
German and Swiss based
manufacturer
BPA is a leading manufacturer of structural waterproofing
products and below ground sealing systems.
With manufacturing locations in both Germany and
Switzerland and quality driven product development teams,
BPA design and manufacture goods specifically for the
Worldwide waterproofing market for below ground structures.
Our range
BPA’s range of waterproofing and concrete construction products include
engineering and architectural waterproofing, concrete technology, concrete sealing,
jointing systems, sealants, waterproofing materials, waterproofing membranes,
bentonite based sealing systems, bentonite double sealing membranes, pre-applied
concrete bonding membranes, self-healing membranes and water stops.
The DualProof waterproofing system is proven technology and has
successfully waterproofed many below-ground concrete structures
since its launch. It can be found in projects in many countries around
the world and is quite simply one of the best performing cost-effective
below-ground waterproofing solutions available today.
Brochure contents
• Innovative Technology
• BS 8102:2009, DIN 18195 T6, DIN V 20000-202
• The benefits of using DualProof
• Typical applications
• A system-based solution
DualProof waterproofing membrane
2 3
The most
innovative
medium-sized
businesses
3. Innovative anti-tracking, pre-applied waterproofing system
The solution that stands the test of lifetime
Concrete Walls Under-Slab Pipe Penetration4 5
4. Below-ground waterproofing
For below-ground structures where the exterior face of the structural concrete is inaccessible, the waterproofing must be applied
prior to pouring the concrete. Conventional systems are either loose-laid or self-adhering to the substrate not the structural
concrete, this means there is no seal between the waterproofing and the structural concrete which can lead to water travelling
between the waterproofing and the structure from any leakages that may occur. BS 8102:2009 highlights this problem and
recommends that a fully-bonded pre-applied waterproofing system be used to mitigate this risk. A similar problem occurs where
ground settlement takes place. BPA has developed an innovative system, DualProof, which incorporates a unique FiberTex-fleece.
The DualProof membrane is installed with the "FiberTex" non-woven fleece facing the concrete which is to be waterproofed.
The fleece mechanically bonds to freshly placed concrete giving a unique waterproof seal, preventing any lateral water migration.
It is installed rapidly with no need for blinding concrete, priming or protection and can be trafficked immediately after application. It
is Radon Gas resistant and highly durable and is unaffected by contaminants within the ground. Quality is assured through MPA,
KIWA, DIN EN 13967, CE-Certification, DIN V 20000-202 and DualProof is suitable for use in accordance with SIA, DIN and BS.
• installation - no blinding concrete or
protection required.
• Assured watertight integrity - overbridges cracks
Mechanical bond to the fresh concrete
• No water-tracking - improoving concrete strength
• Easy jointing independent of temperature
-working temperature -5 up to 45 degree Celsius
• Integrity assured at pile caps
• Excellent solution for insitu concrete.
• Protects structure against ground
contaminants and slat water
• Long term watertight durability
The actual BS 8102:2009 standard for waterproofing below-ground structures, gives
recommendations and provides guidance on methods of dealing with and preventing the
entry of water from surrounding ground into a structure below ground level. Designers are
encouraged to follow a process chart, to ensure that the correct waterproofing system will be
selected. Some of the recommendations are highlighted below;
• To help mitigate risk, specify a combination of various types of compatible protection
sourced from the same manufacturer -- BPA combines Type A and Type B waterproofing
• Where a waterproofing barrier is required for a structure supported on piled foundations,
special consideration should be given to the detailing so that structural continuity is not
compromised.
• Strategies for dealing with groundwater, soil gases and contaminants should be
considered from the earliest stages of the planning and design processes.
• Products that are both water and gasproof are more cost-effective. DualProof is Radon-tight!
• Where waterproofing admixtures are used, these should be in conjunction with other
waterproofing components supplied by the same manufacturer, e.g. waterstops,
membranes and sealants.
• Fully bonded systems allow potential defects to be located and made good more easily.
• Each project structure should be designed to its particular Grade
BS 8102:2009, DIN, SIA
Grade Example of use of structure Performance level
1 Car parking; Plant rooms
(excluding electrical equipment);
Workshops.
Some seepage and damp areas
tolerable, dependent on the intended
use.
Local drainage might be necessary to
deal with seepage.
2 Plant rooms and Workshops
requiring a drier environment (than
grade 1); Storage areas.
No water penetration acceptable.
Damp areas tolerable; ventilation might
be required.
3 Ventilated residential and
commercial areas, including
offices, restaurants etc ; Leisure
centres.
No water penetration acceptable.
Ventilation, dehumidification or air
conditioning necessary, appropriate to
the intended use.
One, or a combination, of the following types of waterproofing protection should be selected:
Type A – (barrier) protection
Protection against water ingress which is dependent on a separate barrier system applied to
the structure. e.g. DualProof, SilverSeal or CEMtobent
Type B – (structural integral) protection
Protection against water ingress which is provided by the concrete structure.
e.g. CEMflex-Admixtures in conjunction with Predimax, CEMswell, Quellmax, CEMflex
Type C – (drained) protection
Protection against water ingress into usable spaces which
is provided by the incorporation of an appropriate internal
water management system. e.g. CEMdrain
DualProof is the professionals choice for fully-bonded Type A barrier protection for below-ground
structures to achive a basement Grades 1, 2 + 3 as described in BS 8102:2009. It is fully compatible
with the BPA CEMdrain drainage and protection board and the CEMflex liquid waterproofing concrete
admixtures assuring best system performance which may be sourced from one premium supplier.
DualProof pre-applied premium waterproofing system "Made in Germany"
• Structural concrete + CEMflex water-stop
•
DualProof - saves time, saves labour cost and money
6 7
DualProof fulfills DIN V 20000-202 Use of building products in construction works
DualProof fulfills DIN 18195 T6 Waterproofing against outside pressing water and
accumulating seepage water, design and execution (German & European)
DualProof fulfills BS 8102 Type A (British) and SIA 272 (Swiss)
DIN - German Standard
SIA - Swiss Standard
BS - British Standard
EN - European Standard
5. BPA below-ground waterproofing solutions
Construction applications
• Single-sided formwork concrete walls
• Double-sided formwork concrete walls
• Pile caps
• Lift pits
• Pipe penetrations
• Expansion and construction joints
BPA system solutions
• pre-applied anti-tracking waterproofing membrane
• - ancillary products
• CEMdicht 3 in 1 - cementitious tanking slurry for pile caps
• / CEM805 active - swellable hydrophilic rubber-based waterstops for joints / hydrophilic bonding and sealing agent
• - PVC waterstops for joints
• MS - one-component flexible sealant for joints
• CEMflex VB - active construction joint waterstop - patented coated steel plate waterstop
•
8 9
6. In the unlikely event of damage to the membrane during
installation, the smart anti-tracking Fiber-tex fleece of DualProof
will prevent any water tracking between the membrane
and the concrete.
DualProof has been tested to ASTM D5385 and
shows no lateral water migration when tested at 50m
hydrostatic water pressure. (University of Nuernberg GER)
The FiberTex Fleece has a positive influence of the water/
cement ratio in the concrete cover zone and improves
the quality of the concrete surface on the very best way.
Non water-tracking
DualProof benefits
Permanently bonds to structural concrete
No blinding concrete required
No membrane protection required
Benefits to owners / designers
Benefits to contractors / installers
DualProof - Fresh Concrete Bonding Waterproofing Membrane
The transparent membrane allows to assess the concrete quality.
It is possible to examine the concrete finish through the installed
membrane after the form-work has been removed.
DualProof will remain in place fully bonded
to the structural concrete assuring complete waterproof
integrity even if ground settlement or concrete cracks occurs.
Made in Germany
High Quality - ISO 9001:2008 TÜV-Süd Germany
Dual Proof fulfills DIN EN 13917 - CE Certification
BS 8102:2009 Type A, DIN 18195 T6, SIA 272
Tanking system with the total security
Aging Test completed - German Radon Gas test passed
Very good mechanical bonding to the concrete
Quality - Technology - Waterproofing - German Engineering
Blinding concrete is preferred,
however DualProof can be
placed directly on top of a well
compacted smooth granular fill
substrate. A broadcast of damp sand
on top of the granular material is
useful.
Removal of the blinding concrete
means less concrete and less labour
time but also means less concrete
truck movements which not only
saves time and money but is more
environment friendly.
DualProof is a robust, heavy
duty membrane with many refererences
in projects throughout the world.
The structural steel reinforcement is
laid directly on top of the membrane
ready for the structural concrete
placement.
There is no requirement for screed
protection which saves valuable
time and money.
An ever increasing level of importance is being placed by owners and designers
with regards to structural integrity, cost-effectiveness and durability. BPA
recognise this, and DualProof with its proven history, excellent holistic
cost benefits and independent certification offers an unparalleled system
solution for below-ground structures to combat these demands. It provides
owners, clients and designers with a high performance system backed by
excellent customer/technical service delivered through a comprehensive
international network.
DualProof is designed for typical site conditions. It is heavy duty, robust
and can be rapidly installed with easy to apply jointing ancillaries which are
system-compatible. The system has a long track record, however BPA
can offer on-site training assistance for specific projects, delivered through
teams of local experts. Contact your BPA office for more details.10 11
Water-tracking test DIN EN 12390-8
and ASTM D5385 up to 5bar water-
pressure (50meter water-head).
7. Typical CAD details
Typical site pictures
Case studies and reference
BPA-Technology has been successfully waterproofing many structures across the world since
its launch in 1998.
Case studies are available along with project references, please contact your BPA
office for full details.
12 13
DualProof Membrane
CEMdicht 3 in 1 crystalline
cementitious waterproofing coating
CEM 805 or CEM 805 active
CEMflex waterstop
DualProof membrane
DualProof membrane CEMflex waterstop
DualProof membrane
CEMflex waterstop
DualProof membrane
8. Delivery to site
Normally DualProof is delivered to site shrink wrapped on pallets and will required mechanical equipment for offloading at site.
Store DualProof rolls vertically. DualProof needs to be stored in a warehouse.
Material storage
Rolls: 1,20 x 25m, 360m²/pallet
Dimensions: 30m²/roll, 44kg/roll, 12 rolls/pallet
Weight: 1,470 g/m²,
PVC-membrane 1,2mm thick, 200g/m² PP FiberTex Fleece
...made in Germany
BPA-Technology has been successfully used throughout the world since its launch in 1998.
System Engineering based on Quality this is what BPA stands for!.
Production Control, Quality Managament System internal and external according to the
DIN EN ISO 9001:2008.
14 15
Production Control
...each roll is labled, contains
manufacturing date and has a
production number!