Công ty TNHH Hạo Phương là đối tác phân phối thiết bị điện công nghiệp của các thương hiệu hàng đầu thế giới như: Fuji Electric, IDEC IZUMI, Kansai Automation, Nichifu, Circutor, Takigen....
2. Ha Noi Office:
No. 95 - TT4, My Dinh Urban Area,
My Dinh, Nam Tu Liem, Hanoi.
Tel: (84 4) 3568 3740
Fax: (84 4) 3568 3741
Cambodia Office:
#140, Room 1-B, St430, Sangkat Toul
Tompuong II, Khan Chamkamon, PP.
Tel: 855 2322 3635
Fax: 855 2322 3645
Head Office:
No 88, Vinh Phu 40, Hoa Long,
Vinh Phu, Thuan An, Binh Duong.
Tel: (84 650) 37 37 619
Fax: (84 650) 37 37 620
1800 6547
THINK TOGETHER
Nhà phân phối thiết bị điện công nghiệp
hàng đầu Việt Nam
T
3. 2
Control Stations (Selection Guide)
Model KGNW AGAW
Note: The degree of protection for AGAW,
AGA, and AGS depends on the
switches or pilot lights to be
mounted.
Mounted Switches &
Pilot Lights
Degree of
Protection
Pushbutton
Pilot light
Illuminated
pushbutton
Selector switch
Selector pushbutton
Mono-lever switch
AC cam switch
AZ electromagnetic
buzzer
AM ammeter
IP65
(IEC 60529)
Key switch
Key reset switch
Key cam switch
Key selector switch
IP54
(IEC 60529)
Square pushbutton
Square pilot light
UC cam switch
(Part No. starting
with U)
IP40
(IEC 60529)
For AGA series deep enclosures,
1 or 2 holes: HNA22 G3/4 (22 mm) × 1
3 to 5 holes: HNA33 G1 (28 mm) × 1
Columns Single Column Single Column
Shape
Degree of
Protection
IP40 (IEC 60529) IP65 (IEC 60529) (Note)
Material (Box) Carbon steel plate Aluminum alloy die-cast
Coating Color 5Y7/1 semi-gloss, melamine coating
5Y7/1 semi-gloss,
melamine coating (outside only)
Standard
Operating
Conditions
Ambient temperature: –25 to +50°C (no freezing)
Relative humidity: 45 to 85% (no condensation)
Style Wall mount (1 to 5 holes)
Wall mount (1 to 5 holes)
Pole mount (1 to 4 holes)
Cable Lead-in
(Wall Mount)
Double knockouts
On top: ø22 and ø27 mm
On bottom: ø16 and ø20 mm
Entrance hub
(Gland hubs are also available)
1 to 3 holes: HNA22 G3/4 (22 mm) × 1
4 to 5 holes: HNA33 G1 (28 mm) × 1
Applicable
Switches/Pilot
Lights
IDEC ø22 mm TW/HW series
Enclosure Size 100, 150, 200, 250, 300H × 80W × 76D mm 150, 200, 300H × 86W × 82D mm
Page 5 8
Model AGA KGN
Columns Single Column Multiple Column Single Column
Shape
Degree of
Protection
IP65 (IEC 60529) (Note) IP40 (IEC 60529)
Material (Box) Die-cast aluminum or cast aluminum Carbon steel plate
Coating Color 5Y7/1 semi-gloss, melamine coating (outside only) 5Y7/1 semi-gloss, melamine coating
Standard
Operating
Conditions
Ambient temperature: –25 to +50°C (no freezing)
Relative humidity: 45 to 85% (no condensation)
Style
Wall mount (1 to 5 holes)
Pole mount (1 to 5 holes)
Wall mount: 4 or 5 holes × 2 columns,
6 holes × 2 or 3 columns
Pole mount: 4 or 5 holes × 2 columns,
6 holes × 2 or 3 columns
Wall mount (1 to 5 holes)
Cable Lead-in
(Wall Mount)
Entrance hub
(Gland hubs are also available)
Standard depth control boxes
1 to 3 holes: HNA22 G3/4 (22 mm) × 1
4 or 5 holes: HNA33 G1 (28 mm) × 1
Deep control boxes
1 or 2 holes: HNA22 G3/4 (22 mm) × 1
3 to 5 holes: HNA33 G1 (28 mm) × 1
Entrance hub
(Gland hubs are also available)
4 to 6 holes × 2 columns:
HNA33 PF1 (28 mm) × 2
6 holes × 3 columns:
HNA33 PF1 (28 mm) × 3
Double knockouts
On top: ø22 and ø27 mm
On bottom: ø16 and ø20 mm
Applicable
Switches/Pilot
Lights
IDEC ø30 mm series, AM ammeter
(except enclosed type units)
IDEC ø30 mm series
Enclosure Size
Standard depth enclosures:
150, 200, 300H × 86W × 82D mm
Deep enclosures:
150, 200, 300H × 86W × 125D mm
2 columns: 320H × 210W × 100D mm
3 columns: 380H × 280W × 132D mm
100, 150, 200, 250, 300H × 80W × 76D mm
Page 12 18 24
4. 3
Control Stations (Selection Guide)
FB Series Plastic Enclosures
Size 76mm 140mm
Model FB1 FB2·2 switches/pilot lights FB2·3 switches/pilot lights
Shape
Degree of Protection
IP65 (with switches/pilot lights)
NEMA Type 4X Indoor Use Only (with switches/pilot lights compliant with Type 4X-compliant)
NEMA Type 1 (with switches/pilot lights not compliant with Type 4X-compliant)
Material Cover/base: polycarbonate, Cover mounting screws: stainless steel
Cover Color Light beige, yellow Light beige
Standard Operating
Conditions
Operating temperature: –25 to +60°C (no freezing)
Relative humidity: 45 to 85% RH (no condensation)
Mounting Holes
0: without mounting hole (light beige only)
1: ø22
0: without mounting hole
2: ø22, mounting centers 50mm
3: ø22, mounting centers 30mm
Applicable Switches/
Pilot Lights
IDEC’s HW/TW/XW series and accessories
Enclosure Size 76H × 76W × 59.5D 140H × 76W × 59.5D
Page 27 27 27
Size 200mm
Model FB3·3 switches/pilot lights FB3·4 switches/pilot lights FB3·5 switches/pilot lights
Shape
Degree of Protection
IP65 (with switches/pilot lights)
NEMA Type 4X Indoor Use Only (with switches/pilot lights compliant with Type 4X-compliant)
NEMA Type 1 (with switches/pilot lights not compliant with Type 4X-compliant)
Material
Cover/base: polycarbonate, Cover mounting screws: stainless steel
Cover Color Light beige
Standard Operating
Conditions
Operating temperature: –25 to +60°C (no freezing)
Relative humidity: 45 to 85% RH (no condensation)
Mounting Holes
0: without mounting hole
3: ø22, mounting centers 50mm
4: ø22, mounting centers 36mm
5: ø22, mounting centers 30mm
Applicable Switches/
Pilot Lights
IDEC's HW/TW/XW series and accessories
Enclosure Size 200H × 76W × 59.5D
Page 27 27 27
5. 4
Model AGS
Columns Single Column Multiple Column
Shape
Degree of
Protection
IP65 (IEC 60529) (Note)
Material (Box) Stainless steel
Coating Color 5Y7/1 semi-gloss, melamine coating (outside only) 5Y7/1 semi-gloss, melamine coating (both inside and outside)
Standard
Operating
Conditions
Ambient temperature: –25 to +50°C (no freezing)
Relative humidity: 45 to 85% (no condensation)
Style
Wall mount (1 to 5 holes)
Pole mount (1 to 5 holes)
Wall mount (3 to 5 holes × 2 columns, 3 to 5 holes × 3 columns)
Pole mount (3 to 5 holes × 2 columns, 3 to 5 holes × 3 columns)
Cable Lead-in
(Wall Mount)
Reducer bushing for connecting a thick steel conduit to lead in
cables
1 to 3 holes: G3/4 (22 mm) × 1
4 or 5 holes: G1 (28 mm) × 1
Reducer bushing for connecting a thick steel conduit to lead in
cables
2 or 3 holes × 2 columns: G3/4 (22 mm) × 2
4 or 5 holes × 2 columns: G1 (28 mm) × 2
2 or 3 holes × 3 columns: G3/4 (22 mm) × 3
4 or 5 holes × 3 columns: G1 (28 mm) × 3
Applicable
Switches/Pilot
Lights
IDEC ø30mm series, AM ammeter (except enclosed type units)
Enclosure Size
150, 200H × 90W × 107D mm (1 to 3 holes)
350H × 118W × 107D mm (4 or 5 holes)
230, 350H × 220W × 108D mm (2 columns)
250, 350H × 310W × 108D mm (3 columns)
Page 34
Note: The degree of protection for AGAW, AGA, and AGS depends on the switches and pilot lights to be mounted. See page 2.
Safety Precautions
•• Be sure to turn off power before mounting, removal, wiring,
maintenance, and inspection. Otherwise, electric shock or
fire hazard may occur.
•• Use wires of a proper size to meet voltage and current
requirements. Tighten terminal screws with a proper tight-
ening torque. Loose terminal screws may cause abnormal
heat and fire. Check periodically for looseness due to
vibrations.
•• To avoid burning your hand, use a lamp holder tool when
replacing lamps.
•• Be sure to use within the rated specifications. Otherwise,
electric shock or fire may occur.
Control Stations (Selection Guide)
6. 5
IP40 Enclosed Steel Control Stations
Mounting of ø22 mm Switches and Pilot Lights
with Space-Saving Design
The KGNW control stations are designed for mounting IDEC ø22 mm
(7/8 inch) switches and pilot lights.
•• Various standard control stations are available from one to four holes
with most widely used combinations of switches and pilot lights (con-
tact configurations, voltage, button colors, and nameplates).
•• Enclosures only are also available, in which specifically selected TW
series can be mounted as required.
KGNW Control Station
with four
ø22 mm swiches/pilot
lights
KGN Control Station
with three
ø30 mm switches/
pilot lights
Ideal for small
control stations
200
mm
•• HW series can also be installed.
Specifications
Degree of Protection IP40 (IEC60529)
Material (Box) Carbon steel plate (t=1.0mm)
Coating Color
(Melamine coating)
Yellow semi-gloss (Munsell 5Y7/1)
Rated Insulation
Voltage
600V
Insulation
Resistance
5 MΩ minimum
Dielectric Strength
Between live and dead parts:
2500V AC, 1 minute
Standard Operating
Conditions
Ambient temperature: –25 to +50°C (no freezing)
Relative humidity: 45 to 85% (no condensation)
Enclosure Style Wall mount (1 holes)
Cable Lead-in
(Wall Mount Type)
Double knockouts
On top: ø22 and ø27 mm
On bottom: ø16 and ø20 mm
Applicable Switches/
Pilot Lights
IDEC ø22 mm TW/HW series
Contact Ratings (Contact Block)
Contact Block
Rated Insulation Voltage 600V
Rated Thermal Current 10A
Contact Ratings by Utilization
Category IEC60947-5-1
AC-15 (A600)
DC-13 (P600)
Operational Voltage and Current by Utilization Category
Operational Voltage 24V 48V 50V 110V 220V 440V
OperationalCurrent
AC
(50/
60Hz)
AC-12 Control of
resistive loads and
solid state loads
10A — 10A 10A 6A 2A
AC-15 Control of
electromagnetic
loads (>72VA)
10A — 7A 5A 3A 1A
DC
DC-12 Control of
resistive loads and
solid state loads
8A 4A — 2.2A 1.1A —
DC-13 Control of
electromagnets
4A 2A — 1.1A 0.6A —
Common
Minimum applicable load (reference value) = 3V AC/DC, 5
mA (the applicable range is subject to change according to
the operating conditions)
Rubber Bushing (Supplied) Color: Black
Enclosure
Style
Supplied Bushing Applicable
Knockout HolePart No. Outside Dia. Inside Dia.
1 or 2 holes GB-2 ø30 mm ø16 mm ø20 or ø22 mm
3 or 4 holes GB-3 ø38 mm ø20 mm ø27 mm
Switches/Pilot Lights Mounting Holes
The holes for mounting switches and pilot lights are 22.2
mm in diameter with an anti-rotation notch.
Mounting centers are 50 mm on 2- and 3-hole enclosures,
and 36 mm on 4-hole enclosures.
Double Knockouts
The top and bottom surfaces have double knockouts.
On top: ø22 and ø27 mm double knockouts
On bottom: ø16 and ø20 mm double knockouts
One rubber bushing is supplied to protect lead-in wires from
damage on the wire surface; 1- and 2-hole enclosures are
supplied with a bushing to fit ø20 and ø22mm holes, and 3-
and 4-hole enclosures with a bushing to fit a ø27 mm hole.
ø22/ø27 mm Double Knockout
Rubber Bushing
Switches/pilot lights
Cover Fastening
Screws
ø16/ø20 mm Double Knockout
KGNW Series Control Stations
7. 6
KGNW Series Control Stations
Control Stations with Switches/Pilot Lights
The control stations are available with selected combination
of switches and pilot lights as listed below. For the
dimensions and mounting centers, see the figures on page 7.
Switches/Pilot Lights Part No. Specifications
Pushbutton
PB
ABW110 * Flush, 1NO
ABW101 * Flush, 1NC
ABW111 * Flush, 1NO-1NC
ABW411 * ø40 mushroom, 1NO-1NC
Pilot Light
PL (Incandescent)
APW116 * Round flush, 110V AC
APW126 * Round flush, 220V AC
Selector Switch
SS
ASW211 Knob, 2-position, 1NO-1NC
ASW320 Knob, 3-position, 2NO
ASW2K11 Key, 2-position, 1NO-1NC
Note: Specify a button or lens color code in place of *:
Pushbutton: B (black), G (green), R (red)
Pilot Light: G (green), R (red), W (white)
Control Stations Package Quantity: 1
Control Station Mounted Switches/Pilot Lights
Style Part No. Symbol Part No.
NWA Nameplate
Legend
WallMount/1hole
KGNW1101Y PB ABW110B ON
KGNW1102Y PB ABW411R Without nameplate
KGNW1103Y PL APW116R Without nameplate
KGNW1104Y PL APW126R Without nameplate
KGNW1105Y SS ASW211 HAND-AUTO
KGNW1106Y SS ASW320 HAND-OFF-AUTO
KGNW1107Y SS ASW2K11 OFF-ON
WallMount/2holes
KGNW2101Y
PB
PB
ABW110B
ABW101R
ON
OFF
KGNW2102Y
PB
PB
ABW111B
ABW111R
ON
OFF
KGNW2103Y
PL
PL
APW116R
APW116G
Without nameplate
KGNW2104Y
PL
PL
APW126R
APW126G
Without nameplate
KGNW2105Y
PL
PB
APW116R
ABW111R
Without nameplate
STOP
KGNW2106Y
PL
PB
APW126R
ABW111R
Without nameplate
STOP
KGNW2107Y
PL
SS
APW116R
ASW211
Without nameplate
HAND-AUTO
KGNW2108Y
PL
SS
APW126R
ASW211
Without nameplate
HAND-AUTO
KGNW2109Y
PL
SS
APW116R
ASW2K11
Without nameplate
OFF-ON
KGNW2110Y
PL
SS
APW126R
ASW2K11
Without nameplate
OFF-ON
KGNW2113Y
PB
PB
ABW110B
ABW411R
ON
Without nameplate
Control Station Mounted Switches/Pilot Lights
Style Part No. Symbol Part No.
NWA Nameplate
Legend
WallMount/3holes
KGNW3102Y
PL
PB
PB
APW116R
ABW110B
ABW101R
Without nameplate
ON
OFF
KGNW3103Y
PL
PB
PB
APW126R
ABW110B
ABW101R
Without nameplate
ON
OFF
KGNW3104Y
PB
PB
SS
ABW111B
ABW111R
ASW211
ON
OFF
HAND-AUTO
KGNW3105Y
PL
PL
PL
APW116W
APW116R
APW116G
Without nameplate
WallMount/4holes
KGNW4101Y
PL
PL
PB
PB
APW126R
APW126G
ABW111B
ABW111R
Without nameplate
Without nameplate
ON
OFF
KGNW4102Y
PL
PB
PB
SS
APW126R
ABW111B
ABW111R
ASW211
Without nameplate
ON
OFF
HAND-AUTO
8. 7
KGNW Series Control Stations
Empty Enclosures Package Quantity: 1
Style Part No.
Unit
Mounting
Hole
Switches/Pilot
Lights Mounting
Centers
1 hole
(approx. 0.4 kg)
KGNW111Y With
NP
3
KGN110Y Without
2 holes
(approx. 0.5 kg)
KGNW212Y With
NP
2228
KGN210Y Without
3 holes
(approx. 0.6 kg)
KGNW313Y With
NP
3
5047
KGN310Y Without
4 holes
(approx. 0.6g) KGNW314Y With
36
2016
36
4 holes
(approx. 0.7 kg)
KGNW414Y With
5050
N P
2822
KGN410Y Without
5 holes
(approx. 0.8 kg)
KGNW515Y With
50505047
KGN510Y Without
Switches/Pilot Lights
Mounting Hole
24
3.5
ø22.2
70 1
Front
Accessories Package Quantity: 1
Name Part No.
Applicable
Enclosure
Applicable
Knockout Hole
Rubber Bushing
GB-2
KGNW111Y
ø20 or ø22 mm
KGN110Y
KGNW212Y
KGN210Y
GB-3
KGNW313Y
ø27 mm
KGN310Y
KGNW314Y
KGNW414Y
KGN410Y
KGNW515Y
KGN510Y
Dimensions All dimensions in mm.
KGNW
30max.80 76
L
37
M4 grounding terminal
M4 grounding terminalø22/ø27 double knockout
ø16/ø20 double knockout
(Mountingholecenters)
6-5 × 8
mounting holes
L1
60
L3
L2
(Centers)
1 hole 2 holes 3 holes 4 holes 5 holes
111Y 212Y 313Y 314Y 414Y 510Y
L 100 150 200 200 250 250
L1 50 100 150 150 200 250
L2 75 125 175 175 225 275
L3 80 130 180 180 230 280
Weight
(Approx.)
0.4 kg 0.5 kg 0.6 kg 0.6 kg 0.7 kg 0.8 kg
Instructions
Precautions for Opening the Knockout Hole
1. The metal piece for the inner
hole of ø22 or ø16 mm knock-
out has two linked parts to the
outer hole. When breaking
the knockout to make an inner
hole, strike the inner metal
piece at the cut parts (the
hatched parts shown as point
A at right) using a screwdriver
tip or similar tool.
2. When opening a larger hole
of ø27 or ø20 mm, first make
a smaller hole as described
above. Then break the knock-
out for the larger hole using
pliers.
Ordering Information
When ordering control stations with switches/pilot
lights:
Specify the Part No. of the control station.
When ordering enclosures without switches/Pilot
lights:
Specify the following items.
1. Part No. of the enclosure
2. Part No. and specifications of the switches/pilot lights to be
mounted (lens color, button color, etc.)
3. Nameplate
4. Other specifications
Ordering Example
Note: Any ø22 mm TW series are selectable. Take the effective
depth inside the enclosure into consideration.
24.1
3.2
ø22.3
Effective Depth inside the Enclosure
All dimension in mm
Point A
Part No. of Enclosure KGNW313Y
Switches/Pi-
lot Lights and
Nameplate
APW126R
ABW210G, with NWA-1
ABW201R, with NWA-2
9. 8
IP65 Waterproof Aluminum Control
Stations for ø22 mm Switches/Pilot Lights
AGAW control stations are designed for mounting IDEC ø22
mm (7/8 inch) switches/pilot lights.
•• Various control stations are available from one to four holes
with most widely used combinations of switches/pilot lights
(contact configurations, voltage, button colors, and name-
plates).
•• Enclosures only are also available, in which specifically
selected TW series can be installed.
200mm
AGAW Control Box
with four
ø22 mm switches/
pilot lights
AGA Control Box
with
three ø30 mm
switches/pilot lights
Ideal for small
control boxes
•• HW series can also be installed.
Specifications
Degree of Protection
(Note)
IP65 (IEC60529)
(Key selector switch: Splash-proof IP54)
Material (Box) Aluminum alloy die-cast
Coating Color
(Melamine coating)
Yellow semi-gloss (Munsell 5Y7/1, outside only)
Rated Insulation
Voltage
600V
Insulation
Resistance
5 MΩ minimum
Dielectric Strength
Between live and dead parts:
2500V AC, 1 minute
Standard Operating
Conditions
Ambient temperature: -25 to +50°C (no freezing)
Relative humidity: 45 to 85% (no condensation)
Style
Wall mount (1 to 4 holes)
Pole mount (1 to 4 holes)
Cable Lead-in
(Wall Mount)
Entrance hub
1 to 3 holes: HNA22 G3/4 (22 mm)
4 to 5 holes: HNA33 G1 (28 mm)
Applicable Switches/
Pilot Lights
IDEC ø22 mm TW series
Note: The degree of protection depends on the switches/pilot lights mount-
ed in the enclosure. When IP65 switches/pilot lights are mounted,
the entire control station has IP65 characteristics. (See page 2)
Contact Ratings (Contact Block)
Contact Block
Rated Insulation Voltage 600V
Rated Thermal Current 10A
Contact Ratings by Utilization
Category IEC60947-5-1
AC-15 (A600)
DC-13 (P600)
Operational Voltage and Current by Utilization Category
Operational Voltage 24V 48V 50V 110V 220V 440V
OperationalCurrent
AC
(50/
60Hz)
AC-12 Control of
resistive loads and
solid state loads
10A — 10A 10A 6A 2A
AC-15 Control of
electromagnetic
loads (72VA)
10A — 7A 5A 3A 1A
DC
DC-12 Control of
resistive loads and
solid state loads
8A 4A — 2.2A 1.1A —
DC-13 Control of
electromagnets
4A 2A — 1.1A 0.6A —
Common
Minimum applicable load (reference) = 3V AC/DC, 5mA (the
applicable range is subject to change according to the operating
conditions)
Switch/Pilot Light Mounting Holes
The holes for mounting switches/pilot lights are 22.2 mm in diam-
eter with an anti-rotation notch.
Mounting centers are 50 mm on 2- and 3-hole enclosures, and 36
mm on 4-hole enclosures.
Waterproof Bushing
Four plastic bushings are provided inside the corners for mount-
ing screws to secure the control station on a panel surface.
Lead-in Fittings (Wall Mount)
An entrance hub made of aluminum is supplied for connecting a
steel conduit to lead in cables.
1 to 3 holes: With HNA22 G3/4 for 22 mm conduit
4 holes: With HNA33 G1 for 28 mm conduit
HNAG gland hubs for lead in cables are also available.
Stand Pole (Pole Mount)
The pole is made of carbon steel pipe, and the base is made of
cast iron. The coating color is the same as the enclosure, yellow
(semi-gloss).
Enclosure
Switch/Pilot Light
Stainless Steel
Screws
Pole
BaseWaterproof BushingEntrance Hub
Unit Mounting
Hole
AGAW Series Control Stations
10. 9
AGAW Series Control Stations
Control Stations with Switches/Pilot Lights
The control stations are available with a selected combina-
tion of switches/pilot lights as listed below. For the dimen-
sions and mounting centers, see the figures on page 10.
Switch/Pilot Light Part No. Specifications
Pushbutton
PB
ABW110 * Flush, 1NO
ABW101 * Flush, 1NC
ABW111 * Flush, 1NO-1NC
ABW411 * ø40 mushroom, 1NO-1NC
Pilot Light
PL (Incandescent)
APW116 * Round flush, 110V AC
APW126 * Round flush, 220V AC
Selector Switch
SS
ASW211 Knob, 2-position, 1NO-1NC
ASW320 Knob, 3-position, 2NO
ASW2K11 Key, 2-position, 1NO-1NC
Note: Specify a button or lens color code in place of * :
Pushbutton: B (black), G (green), R (red)
Pilot Light: G (green), R (red), W (white)
Control Stations Package Quantity: 1
Control Station Mounted Switches/Pilot Lights
Style Part No. Symbol Part No.
NWA Nameplate
Legend
WallMount/1hole
AGAW1101Y PB ABW110B ON
AGAW1102Y PB ABW411R Without nameplate
AGAW1105Y SS ASW211 HAND-AUTO
AGAW1107Y * SS ASW2K11 OFF-ON
PoleMount/
1hole
AGAW1101SY PB ABW110B ON
AGAW1102SY PB ABW411R OFF
WallMount/2holes
AGAW2101Y
PB
PB
ABW110B
ABW101R
ON
OFF
AGAW2102Y
PB
PB
ABW111B
ABW111R
ON
OFF
AGAW2103Y
PL
PL
APW116R
APW116G
Without nameplate
AGAW2104Y
PL
PL
APW126R
APW126G
Without nameplate
AGAW2105Y
PL
PB
APW116R
ABW111R
Without nameplate
STOP
AGAW2106Y
PL
PB
APW126R
ABW111R
Without nameplate
STOP
AGAW2107Y
PL
SS
APW116R
ASW211
Without nameplate
HAND-AUTO
Degree of protection marked with * is splash-proof IP54.
Control Station Mounted Switches/Pilot Lights
Style Part No. Symbol Part No.
NWA Nameplate
Legend
WallMount/2holes
AGAW2108Y
PL
SS
APW126R
ASW211
Without nameplate
HAND-AUTO
AGAW2109Y *
PL
SS
APW116R
ASW2K11
Without nameplate
OFF-ON
AGAW2110Y *
PL
SS
APW126R
ASW2K11
Without nameplate
OFF-ON
AGAW2113Y
PB
PB
ABW110B
ABW411R
ON
Without nameplate
PoleMount/
2holes
AGAW2101SY
PB
PB
ABW110B
ABW101R
ON
OFF
WallMount/3holes
AGAW3102Y
PL
PB
PB
APW116R
ABW110B
ABW101R
Without nameplate
ON
OFF
AGAW3103Y
PL
PB
PB
APW126R
ABW110B
ABW101R
Without nameplate
ON
OFF
AGAW3104Y
PB
PB
SS
ABW111B
ABW111R
ASW211
ON
OFF
HAND-AUTO
PoleMount/3holes
AGAW3102SY
PL
PB
PB
APW116R
ABW110B
ABW101R
Without nameplate
ON
OFF
AGAW3104SY
PB
PB
SS
ABW111B
ABW111R
ASW211
ON
OFF
HAND-AUTO
Wall·Pole/4holes
Wall Mount
AGAW4101Y
PL
PL
PB
PB
APW126R
APW126G
ABW111B
ABW111R
Without nameplate
Without nameplate
ON
OFFPole Mount
AGAW4101SY
Wall Mount
AGAW4102Y
PL
PB
PB
SS
APW126R
ABW111B
ABW111R
ASW211
Without nameplate
ON
OFF
HAND-AUTOPole Mount
AGAW4102SY
Degree of protection marked with * is splash-proof IP54.
11. 10
AGAW Series Control Stations
Empty Enclosures Package Quantity: 1
Style Part No.
Unit Mount-
ing Hole
Switch/Pilot Light
Mounting Centers
1 hole
(approx. 0.6 kg)
AGAW211Y With
G3/4 (22mm)
Hub HNA22
NP
AGA210Y Without
2 holes
(approx. 0.6 kg)
AGAW212Y With
NP
2723
G3/4 (22mm)
Hub HNA22
3 holes
(approx. 0.7 kg)
AGAW313Y With
NP
50248
G3/4 (22mm)
Hub HNA22AGA310Y Without
4 holes
(approx. 0.7 kg)
AGAW314Y With
NP
36
G1 (28mm)
Hub HNA33
4 holes
(approx. 0.9 kg)
AGAW514Y Without
5 holes
(approx. 0.9 kg)
KGNW515Y With
KGN510Y Without
Switch/Pilot Light Mounting Hole
24
3.5
ø22.2
An entrance hub is supplied.
1 to 3 holes: With HNA22 G3/4 for
22 mm conduit
4 holes: With HNA33 G1 for 28
mm conduit
77
70
79
Standard
Dimensions All dimensions in mm.
AGAW Control Station (Wall Mount)
(72)
(1.2)
(95) (132)
8286
L
30
30max.
Shade
Hub
M4 grounding terminal
HNA22:31
HNA33:35
Nameplate
O N
O F F
4-ø4.4
Mounting holes
60 (Centers)
I
•• Entrance Hub (attached)
1 to 3 holes: HNA22 G3/4 (22 mm)
4 holes: HNA33 G1 (28 mm)
•• Gland hubs for leading in cables are also available.
See page 39 for details.
Part No.
Applicable Cable
Diameter (R)
HNG21 8, 10, 12
HNAG22 13, 15, 17
HNAG33 18, 20, 22
1 hole 2 holes 3 holes 4 holes 5 holes
211Y 212Y 313Y 314Y 514Y 510Y
L 100 150 200 200 300 300
l 114 114 164 164 264 264
Weight
(Approx.)
0.6 kg 0.6 kg 0.7 kg 0.6 kg 0.7 kg 0.8 kg
AGAW Control Station (Pole Mount)
ø200
(1.2)
(72)
(95)
ø230
10
100L
H
86 82
(132)
4-ø14
Mounting hole
M6
Grounding
terminal
Shade
1 hole 2 holes 3 holes 4 holes 4 holes 5 holes
H 1350 1400 1500 1500
L 150 200 300 300
Weight
(Approx.)
6.1 kg 6.2 kg 6.4 kg 6.4 kg
24
3.5
ø22.2
Effective Depth inside the Enclosure
12. 11
AGAW Series Control Stations
Accessory (Options) Package Quantity: 1
Name Shape Part No. Description Dimensions
Enclosure Shade
132
95
70
Material: Carbon steel plate
Thickness: 1 mm
Weight: Approx. 0.25 kg
AGZ-S1Y
•• Protection for switches/pilot lights against direct sunlight and falling
objects.
•• Color: Yellow (semi-gloss)
•• Shade mounting hole
2-M4 tapped hole: Depth 5
Pilot hole: Depth 5.5 max.
(no penetration)
68
46.5
Stand Pole
Weight: Approx. 5.6 kg
AGZ-S205
•• For replacement of the base and pole.
•• Color: Yellow (semi-gloss)
(1005)
ø52
4-ø6.5
Hole
65
51
72
50
10
(1199)
(8to9)
94
2
1°
100
ø230
ø200
Sealing base
Grounding
terminal
(8 to 9)
Pole
Outside Dia.: ø48.6
Inside Dia.: ø44.0
Stand gasket
Base
4-ø14 Hole
Instructions
Precautions for Mounting on Panel (Wall)
1. Insert M4 screws into the
waterproof bushings at all
four corners inside the box.
Push the screws with a
screwdriver and penetrate
the bushings (Figure 1).
2. Thrust the screws into
panel holes and secure the
screws with nuts (Figure 2).
Waterproof characteristics
are not affected by piecing
the bushings with screws.
Ordering Information
When ordering control stations with switches/pilot lights:
Specify the Part No. of the control station.
When ordering enclosures without switches/pilot lights:
Specify the following items.
1. Part No. of the enclosure
2. Part No. and specifications of the switches/pilot lights to be
mounted (lens color, button color, etc.)
3. Nameplate
4. Lead-in fitting
Only when ordering the gland hub for leading in cables, specify
the Part No. and the finished cable outside diameter (R).
5. Other specifications
Ordering Example
Note: Any ø22 mm TW/HW series are selectable. Take into con-
sideration the degree of protection of the switches/pilot light
and the effective depth of the enclosure.
Figure 1
Box
Waterproof Bushing
13
Figure 2
Panel surface Part No. of Enclosure AGAW313Y
Switch/Pilot
Light and
Nameplate
APW126R
ABW210G, with NWA-1
ABW201R, with NWA-2
Lead-in Fitting HNAG22 R15
All dimensions in mm.
13. 12
IP65 Waterproof Aluminum Control
Stations for ø30 mm Switches/Pilot Lights
Various control stations are available from one to five holes
with most widely used combinations of switches/pilot lights
(contact configurations, voltage, button colors, and name-
plates).
•• Versatile combinations of switches/pilot lights are possible.
Select from a wide variety of 30 mm (1-13/64 inch) dia.
switches/pilot lights as required.
•• In addition to standard depth enclosures, deep enclosures
are also available for mounting illuminated pushbuttons
which require a large depth behind the mounting surface.
(See page 15 for more details).
Specifications
Degree of Protection
(Note 1)
IP65 (IEC60529)
(Key selector switch: Splash-proof IP54)
Material (Enclosure) Aluminum alloy die-cast
Coating Color
(Melamine coating)
Yellow semi-gloss (Munsell 5Y7/1, outside only)
Rated Insulation
Voltage
600V (Buzzer: 250V)
Insulation
Resistance
5 MΩ minimum
Dielectric Strength
(Note 2)
Between live and dead parts:
2500V AC, 1 minute
Standard Operating
Conditions (Note 3)
Ambient temperature: -25 to +50°C (no freezing)
Relative humidity: 45 to 85% (no condensation)
Enclosure Style
Wall mount (1 to 5 holes)
Pole mount (1 to 5 holes)
Cable Lead-in Hole
(Wall Mount)
Entrance hub (Gland hub also available)
1 to 3 holes: HNA22 G3/4 (22 mm)
4 or 5 holes: HNA33 G1 (28 mm)
(Standard control stations)
Applicable Switch-
es/Pilot Lights
IDEC ø30 mm series
AZ buzzer and AM ammeter
(except enclosed type units)
Note 1: The degree of protection depends on the switches/pilot lights
mounted on the enclosure. When IP65 switches/pilot lights are
mounted, the entire control station has IP65 characteristics. (See
page 2)
Note 2: AM ammeter/buzzer: 2000V AC, 1 minute
Note 3: Buzzer: -10 to +40°C
Contact Ratings (Contact Block)
Contact Block
Rated Insulation Voltage 600V
Rated Thermal Current 10A
Contact Ratings by Utilization
Category IEC60947-5-1
AC-15 (A600)
DC-13 (P600)
Operational Voltage and Current by Utilization Category
Operational Voltage 24V 48V 50V 110V 220V 440V
OperationalCurrent
AC
(50/
60Hz)
AC-12 Control of
resistive loads and
solid state loads
10A — 10A 10A 6A 2A
AC-15 Control of
electromagnetic
loads (72VA)
10A — 7A 5A 3A 1A
DC
DC-12 Control of
resistive loads and
solid state loads
10A 5A — 2.2A 1.1A —
DC-13 Control of
electromagnets
5A 5A — 1.1A 0.6A —
Common
Minimum applicable load (reference) = 3V AC/DC, 5mA (the
applicable range is subject to change according to the operating
conditions )
Switch/Pilot Light Mounting Holes
The holes for mounting switches/pilot lights are 30.5 mm in diam-
eter with an anti-rotation notch. Mounting centers are 50 mm.
Waterproof Bushing
Four plastic bushings are provided inside the corners for mount-
ing screws to secure the control station on a panel surface.
Lead-in Fittings (Wall Mount)
An entrance hub made of aluminum is supplied for connecting a
steel conduit to lead in cables.
1 to 3 holes: With HNA22 G3/4 for 22mm conduit
4 or 5 holes: With HNA33 G1 for 28mm conduit
HNAG gland hubs for leading in cables are also available.
Stand Pole (Pole Mount)
The pole is made of carbon steel pipe, and the stand base is
made of cast iron. The coating color is the same as the enclosure,
yellow (semi-gloss).
Enclosure
Switch/Pilot Light
Unit Mounting
Hole
Stainless Steel Screws
Pole
Base
Waterproof BushingEntrance Hub
AGA Series Control Stations (Single Column)
14. 13
AGA Series Control Stations (Single Column)
Control Stations with Switches/Pilot Lights
Control boxes are available with a selected combination
of switches/pilot lights as listed below. For the dimensions
and mounting centers, see the figures on pages 15 and 16.
Switches/Pilot Lights Mounted on Standard Control Stations
Switch/Pilot Light Part No. Specifications
Pushbutton
PB
ABN110 * Flush, 1NO
ABN101 * Flush, 1NC
ABN111 * Flush, 1NO-1NC
ABN311R ø40 mushroom, 1NO-1NC
ABBN1110 ** Flush, double beam latching, 1NO
ABBN1111 **
Flush, double beam latching,
1NO-1NC
ATN420 Toggle lever, 2NO
HN1E-BV411R Emergency stop, 1NO-1NC
Pilot Light
PL (Incandescent)
APN118 * Dome, 110V AC (2W)
APN128 * Dome, 220V AC (2W)
Selector Switch
SS
ASN311 Knob, 2-position, 1NO-1NC
ASN111 Knob, 3-position, 1NO-1NC
ASN3K11 Key, 2-position, 1NO-1NC
Buzzer
SS
AZ11N 110V AC
AZ12N 220V AC
Meter
A AM ammeter
Specify capacity (Part No.)
Coating color of the meter
bezel: N1.5
Note: Specify a button or lens color code in place of *:
Pushbutton: B (black), G (green), R (red)
Pilot Light: G (green), R (red), W (white)
Flush pushbuttons are supplied with black, green, and red color caps.
Capacity and Part No. of AM Ammeters
Capacity Part No. Remarks
Ammeter
5A (nominal) AM21B
•• Use a current
transformer on am-
meters of 30A rating
or more.
10A (nominal) AM22B
15A (nominal) AM23B
30/5A (nominal) AM24CB
60/5A (nominal) AM25CB
100/5A (nominal) AM26CB
150/5A (nominal) AM27CB
200/5A (nominal) AM28CB
300/5A (nominal) AM29CB
/5A (nominal) AM2CB *
Note 1: When ordering, specify the Part No. Also specify a current value
for the ammeter marked with *.
Note 2: The dial has a double-expanded scale. Also available are for
triple-expanded scales, 1A meters and other special ratings. Con-
tact IDEC for details about other special specifications.
Package Quantity: 1
Control Station Mounted Switches/Pilot Lights
Style Part No. Symbol Part No.
NA Nameplate
Legend
WallMount/1hole
AGA1101Y PB ABN110 ON
AGA1102Y PB ABN311R OFF
AGA1103Y PL APN118R Without nameplate
AGA1104Y PL APN128R Without nameplate
AGA1105Y SS ASN311 HAND-AUTO
AGA1106Y SS ASN111 HAND-OFF-AUTO
Control Station Mounted Switches/Pilot Lights
Style Part No. Symbol Part No.
NA Nameplate
Legend
WallMount/1hole
AGA1107Y * SS ASN3K11 OFF-ON
AGA1108Y BZ AZ11N Without nameplate
AGA1109Y BZ AZ12N Without nameplate
AGA1110Y PB ATN420
Without nameplate
ON-OFF on bezel
AGA1111Y PB
HN1E-
BV411R
EMERGENCY
STOP
PoleMount/
1hole
AGA1101SY PB ABN110 ON
AGA1102SY PB ABN311R OFF
AGA1111SY PB
HN1E-
BV411R
EMERGENCY
STOP
WallMount/2holes
AGA2101Y
PB
PB
ABN110
ABN101
ON
OFF
AGA2102Y
PB
PB
ABN111
ABN111
ON
OFF
AGA2103Y
PL
PL
APN118R
APN118G
Without nameplate
AGA2104Y
PL
PL
APN128R
APN128G
Without nameplate
AGA2105Y
PL
PB
APN118R
ABN111
Without nameplate
STOP
AGA2106Y
PL
PB
APN128R
ABN111
Without nameplate
STOP
AGA2107Y
PL
SS
APN118R
ASN311
Without nameplate
HAND-AUTO
AGA2108Y
PL
SS
APN128R
ASN311
Without nameplate
HAND-AUTO
AGA2110Y *
PL
SS
APN128R
ASN3K11
Without nameplate
OFF-ON
AGA2111Y
PB
PB
ABBN1110 ON-OFF
AGA2112Y
PB
PB
ABBN1111 ON-OFF
AGA2113Y
PB
PB
ABN110
ABN311R
ON
OFF
AGA2115Y
PL
PB
APN128R
ATN420
Without nameplate
ON-OFF on bezel
AGA2116Y
BZ
PB
AZ11N
ABN111
Without nameplate
AGA2117Y
BZ
PB
AZ12N
ABN111
Without nameplate
AGA2118Y
BZ
PL
AZ11N
APN118R
Without nameplate
AGA2119Y
BZ
PL
AZ12N
APN128R
Without nameplate
Degree of protection marked with * is splash-proof IP54.
15. 14
AGA Series Control Stations (Single Column)
Control Station Mounted Switches/Pilot Lights
Style Part No. Symbol Part No.
NA Nameplate
Legend
PoleMount/
2holes
AGA2101SY
PB
PB
ABN110
ABN101
ON
OFF
AGA2107SY
PL
SS
APN118R
ASN311
Without nameplate
HAND-AUTO
WallMount/3holes
AGA3102Y
PL
PB
PB
APN118R
ABN110
ABN101
Without nameplate
ON
OFF
AGA3103Y
PL
PB
PB
APN128R
ABN110
ABN101
Without nameplate
ON
OFF
AGA3104Y
PB
PB
SS
ABN111
ABN111
ASN311
ON
OFF
HAND-AUTO
AGA3105Y
PL
PL
PL
APN118W
APN118R
APN118G
Without nameplate
AGA3106Y
PL
PL
PL
APN128W
APN128R
APN128G
Without nameplate
AGA3107Y
PL
PB
PB
APN118R
ABBN1110
Without nameplate
ON
OFF
AGA3108Y
PL
PB
PB
APN128R
ABBN1110
Without nameplate
ON
OFF
Control Station Mounted Switches/Pilot Lights
Style Part No. Symbol Part No.
NA Nameplate
Legend
PoleMount/3holes
AGA3102SY
PL
PB
PB
APN118R
ABN110
ABN101
Without nameplate
ON
OFF
AGA3104SY
PB
PB
SS
ABN111
ABN111
ASN311
ON
OFF
HAND-AUTO
Wall·Pole/4holes
Wall Mount
AGA4101Y
PL
PL
PB
PB
APN128R
APN128G
ABN111
ABN111
Without nameplate
Without nameplate
ON
OFFPole Mount
AGA4101SY
Wall Mount
AGAM4101Y A
PB
PB
(Note)
AM ammeter
ABN111
ABN111
Without nameplate
ON
OFF
Pole Mount
AGAM4101SY
Wall Mount
AGA4102Y PL
PB
PB
SS
APN128R
ABN111
ABN111
ASN311
Without nameplate
ON
OFF
HAND-AUTOPole Mount
AGA4102SY
Wall·Pole/5holes
Wall Mount
AGA5101Y
PL
PL
PB
PB
SS
APN128R
APN128G
ABN111
ABN111
ASN311
Without nameplate
Without nameplate
ON
OFF
HAND-AUTOPole Mount
AGA5101SY
Wall Mount
AGAM5101Y A
PL
PB
PB
(Note)
AM ammeter
APN128R
ABN111
ABN111
Without nameplate
Without nameplate
ON
OFF
Pole Mount
AGAM5101SY
Note: Specify the Part No. of the meter to select a required capacity.
16. 15
AGA Series Control Stations (Single Column)
Empty Enclosures Package Quantity: 1
Style 1 or 2 holes 3 holes 4 or 5 holes
Part
No.
AGA210Y AGA211Y AGA212Y AGA310Y AGA311Y AGA411Y AGA412Y AGA510Y AGA511Y AGA512Y
AGA210DY AGA211DY AGA212DY AGA310DY AGA311DY AGA411DY AGA412DY AGA510DY AGA511DY AGA512DY
AGA210HLY AGA211HLY AGA212HLY AGA310HLY AGA311HLY AGA411HLY AGA412HLY AGA510HLY AGA511HLY AGA512HLY
Shape
50
50
50
5075
50
5075
Weight
(Approx.)
0.6 kg 1.0 kg 0.5 kg 0.7 kg 1.2 kg 0.6 kg 0.9 kg 1.4 kg 0.8 kg
: Standard depth enclosure with an entrance hub
1 to 3 holes: With HNA22 G3/4 entrance hub for 22 mm conduit
4 or 5 holes: With HNA33 G1 entrance hub for 28 mm conduit
: Deep enclosure with an entrance hub
1 or 2 holes: With HNA22 G3/4 entrance hub for 22 mm conduit
3 to 5 holes: With HNA33 G1 entrance hub for 28 mm conduit
: Standard depth enclosure without an entrance hub
1 to 3 holes: With a threaded hole G3/4 (22 mm) at the bottom
4 or 5 holes: With a threaded hole G1 (28 mm) at the bottom
•• Switch/Pilot Light Mounting Holes
31.7
4.5
ø30.5
(Meter Mounting Hole)
112.5
121
11977
70
79
Deep
enclosure
Standard depth
enclosure
In addition to the enclosures shown above, enclosures with a shade and pole mount enclosures are also available. See the list below and page 16.
Other Types (For 1, 2 or 3 holes) Package Quantity: 1
Style 1 or 2 holes 3 holes
Hub Shade Pole
Part No.
Standard
depth
enclosure
X X AGA210KY AGA211KY AGA212KY AGA310KY AGA311KY
X AGA210SY AGA211SY AGA212SY AGA310SY AGA311SY
X X AGA210KSY AGA211KSY AGA212KSY AGA310KSY AGA311KSY
X AGA210KHLY AGA211KHLY AGA212KHLY AGA310KHLY AGA311KHLY
Deep
enclosure
X X AGA210DKY AGA211DKY AGA212DKY AGA310DKY AGA311DKY
X AGA210DSY AGA211DSY AGA212DSY AGA310DSY AGA311DSY
X X AGA210DKSY AGA211DKSY AGA212DKSY AGA310DKSY AGA311DKSY
Shape
50
50
Weight
(Approx.)
Standard
depth
enclosure
With a shade 0.85 kg 0.85 kg 0.85 kg 0.95 kg 0.95 kg
Pole mount 6.1 kg 6.1 kg 6.1 kg 6.2 kg 6.2 kg
Pole mount with a shade 6.4 kg 6.4 kg 6.4 kg 6.5 kg 6.5 kg
With a shade (without a hub) 0.75 kg 0.75 kg 0.75 kg 0.85 kg 0.85 kg
Deep
enclosure
With a shade 1.25 kg 1.25 kg 1.25 kg 1.45 kg 1.45 kg
Pole mount 6.75 kg 6.75 kg 6.75 kg 6.95 kg 6.95 kg
Pole mount with a shade 7.0 kg 7.0 kg 7.0 kg 7.1 kg 7.1 kg
All dimensions in mm.
•• Effective Depth inside the Enclosure
17. 16
AGA Series Control Stations (Single Column)
Other Types (For 4 or 5 holes) Package Quantity : 1
Style 4 or 5 holes
Hub Shade Pole
Part No.
Standard
depth
enclosure
X X AGA411KY AGA412KY AGA510KY AGA511KY AGA512KY
X AGA411SY AGA412SY AGA510SY AGA511SY AGA512SY
X X AGA411KSY AGA412KSY AGA510KSY AGA511KSY AGA512KSY
X AGA411KHLY AGA412KHLY AGA510KHLY AGA511KHLY AGA512KHLY
Deep
enclosure
X X AGA411DKY AGA412DKY AGA510DKY AGA511DKY AGA512DKY
X AGA411DSY — AGA510DSY AGA511DSY AGA512DSY
X X AGA411DKSY — AGA510DKSY AGA511DKSY AGA512DKSY
Shape
50
5075
50
5075
Weight
(Approx.)
Standard
depth
enclosure
With a shade 1.15 kg 1.15 kg 1.15 kg 1.15 kg 1.15 kg
Pole mount 6.4 kg 6.4 kg 6.4 kg 6.4 kg 6.4 kg
Pole mount with a shade 6.65 kg 6.65 kg 6.65 kg 6.65 kg 6.65 kg
With a shade (without a hub) 1.05 kg 1.05 kg 1.05 kg 1.05 kg 1.05 kg
Deep
enclosure
With a shade 1.65 kg 1.65 kg 1.65 kg 1.65 kg 1.65 kg
Pole mount 6.9 kg — 6.9 kg 6.9 kg 6.9 kg
Pole mount with a shade 7.15 kg — 7.15 kg 7.15 kg 7.15 kg
•• For details about enclosures without switches/pilot lights, see page 15.
Dimensions All dimensions in mm.
AGA Control Station (Wall Mount)
M4
grounding
terminal
Shade
Shade
30
(55)
82
(125)
(132)
(175)
55
125
HubHub
M4
grounding
terminal
(95)
(70)
l
l
L
60
86
ON
OFF
HNA22:31
HNA33:35
IDEC
4-ø4.4 4-ø4.4
Dimensions in ( ) for a control box with a shade.
1 hole 2 holes 3 holes 4 holes 5 holes
L 150 200 300
| 114 164 264
Weight (Approx.) 0.6 kg 0.7 kg 0.9 kg
Entrance Hub (Supplied)
(Standard depth enclosures)
1 to 3 holes: With HNA22 G3/4 for 22 mm conduit
4 or 5 holes: With HNA33 G1 for 28 mm conduit
(Deep enclosures with an entrance hub)
1 or 2 holes: With HNA22 G3/4 for 22 mm conduit
3 to 5 holes: With HNA33 G1 for 28 mm conduit
Gland hubs for leading in cables are also available.
Part No.
Applicable Cable
Diameter (R)
HNG21 8, 10, 12
HNAG22 13, 15, 17
HNAG33 18, 20, 22
AGA Control Station (Pole Mount)
(70)10
100
86
(95)
95
ø230
ø200
L
ø48.6
H
OFF
ON
IDEC
(175)
55
125Shade
82
(132)
Shade
M6
Grounding
terminal
4-ø14
Mounting
hole
Dimensions in ( ) for a control box with a shade.
1 hole 2 holes 3 holes 4 holes 5 holes
H 1350 1400 1500
L 150 200 300
Weight (Approx.) 6.1 kg 6.2 kg 6.4 kg
18. 17
AGA Series Control Stations (Single Column)
Accessory (Options) Package Quantity: 1
Name Shape Part No. Description Dimensions
Enclosure Shade
132
95
70
Material: Carbon steel plate
Thickness: 1 mm
Weight: Approx. 0.25 kg
AGZ-S1Y
••Protection for switches/pilot lights against direct sunlight and falling
objects.
••Color: Yellow semi-gloss (Munsell 5Y7/1)
••Shade mounting hole
2-M4 tapped hole: Depth 5
Pilot hole: Depth 5.5 max.
(no penetration)68
A∗
* Dimension A
AGA210, 310, 510: 46.5 mm
AGA210D, 310D, 510D: 90 mm
Stand Pole
Weight: Approx. 5.6 kg
AGZ-S205
••For replacement of the stand pole.
••Color: Yellow semi-gloss (Munsell 5Y7/1)
(1005)
ø52
4-ø6.5
Hole
65
51
72
50
10
(1199)
(8to9)
94
2
1°
100
ø230
ø200
Sealing base
Grounding
terminal
(8 to 9)
Pole
Outside Dia.: ø48.6
Inside Dia.: ø44.0
Stand gasket
Base
4-ø14 Hole
Instructions
Precautions for Mounting on Panel (Wall)
1. Insert M4 screws into the waterproof bushings at all four cor-
ners inside the box. Push the screws with a screwdriver and
penetrate the bushings (Figure 1).
2. Thrust the screws into panel holes and secure the screws with
nuts (Figure 2). Waterproof characteristics are not affected by
piecing the bushings with screws.
Figure 1
Box
Waterproof Bushing
13
Figure 2
Panel surface
Ordering Information
When ordering control stations with switches/pilot lights:
Specify the Part No. of the control station.
When ordering enclosures without switches/pilot lights:
Specify the following items.
1. Part No. of the enclosure
2. Part No. and specifications of the switches/pilot lights to be
mounted (lens color, button color, etc.)
3. Nameplate
4. Lead-in fitting
Only when ordering the gland hub for lead in cables, specify the
Part No. and the cable outside diameter (R).
5. Other specifications
Ordering Example
Note: Any ø30 mm series switches/pilot lights are selectable.
Take into consideration the degree of protection of the
switches/pilot lights and the effective depth of the enclo-
sure.
Part No. of Enclosure AGA311Y
Switch/Pilot
Light and
Nameplate
APN128R
ABN210B, with NA-1
ABN201R, with NA-2
Lead-in Fitting HNAG22 R15
All dimensions in mm.
19. 18
IP65 Waterproof Multiple Column
Aluminum Control Stations
Versatile Combinations of Switches/Pilot Lights
The AGA multiple column control stations are designed for
mounting various types of switches/pilot lights in various
combinations. Standard control stations are available with
predetermined specifications of cable lead-in holes and the
switches/pilot lights to be mounted (contact configurations,
voltage, button colors, and nameplates).
•• Versatile combinations of switches/pilot lights are possible.
Select from a wide variety of 30 mm (1-13/64 inch) dia.
switches/pilot lights.
•• The lid of the enclosure is hinged to make wiring and mainte-
nance easy.
Specifications
Model AGA480 / AGA580 AGA680 / AGA690
Degree of Protection
(Note 1)
IP65 (IEC60529)
Material (Enclosure) Aluminum alloy die-cast
Coating Color
(Melamine coating)
Yellow semi-gloss (Munsell 5Y7/1, outside only)
Rated Insulation
Voltage
600V (Buzzer: 250V)
Insulation Resis-
tance
5 MΩ minimum
Dielectric Strength
(Note 2)
Between live and dead parts:
2500V AC, 1 minute
Standard Operating
Conditions
(Note 3)
Ambient temperature: -25 to +50°C (no freezing)
Relative humidity: 45 to 85% (no condensation)
Enclosure Style
Wall mount/pole mount
(4 × 2 or 5 × 2 holes)
Wall mount/pole
mount
(6 × 2 or 6 × 3 holes)
Cable Lead-in
(Wall Mount)
Entrance hub (Gland hub also available)
HNA33 G1 (28 mm)
Applicable Switch-
es/Pilot Lights
IDEC ø30 mm series, AZ buzzer and AM am-
meter
(except enclosed type units)
Note 1: The degree of protection depends on the switches/pilot lights
mounted on the enclosure. When IP65 switches/pilot lightss are mounted,
the entire control station has IP65 characteristics. (See page 2)
Note 2: AM ammeter/buzzer: 2000V AC, 1 minute
Note 3: Buzzer: -10 to +40°C
Contact Ratings (Contact Block)
Contact block
Rated Insulation Voltage 600V
Rated Thermal Current 10A
Contact Ratings by Utilization
Category IEC60947-5-1
AC-15 (A600)
DC-13 (P600)
Operational Voltage and Current by Utilization Category
Operational Voltage 24V 48V 50V 110V 220V 440V
OperationalCurrent
AC(50/60Hz)
AC-12 Control of resis-
tive loads and solid
state loads
10A − 10A 10A 6A 2A
AC-15 Control of
electromagnetic loads
(72VA)
10A − 7A 5A 3A 1A
DC
DC-12 Control of resis-
tive loads and solid
state loads
10A 5A − 2.2A 1.1A −
DC-13 Control of elec-
tromagnets
5A 2A − 1.1A 0.6A −
Common
Minimum applicable load (reference) = 3V AC/DC, 5mA (the
applicable range is subject to change according to the operating
conditions)
Switch/Pilot Light Mounting Holes
The holes for mounting switches/pilot lights are 30.5 mm in diam-
eter with an anti-rotation notch. Mounting centers are 50 mm.
Lead-in Fittings (Wall Mount)
An entrance hub made of aluminum is supplied for connecting a
steel conduit to lead in cables.
AGA480 (4 × 2 holes), AGA580 (5 × 2 holes):
With two HNA33 G1 for 28 mm conduit
(Available with one HNA33, upon request)
AGA680 (6 × 2 holes): With two HNA33 G1 for 28 mm conduit
AGA690 (6 × 3 holes): With three HNA33 G1 for 28 mm conduit
Gland hubs for lead in cables are also available.
Stand Pole (Pole Mount)
The pole is made of carbon steel pipe, and the base is made of
cast iron. The coating color is the same as the enclosure, yellow
(semi-gloss).
EnclosureLid Hinge
Switch/Pilot
Light
Unit Mounting Hole
Stainless Steel Screws
Pole
Base
Waterproof Bushing
Entrance Hub
AGA Series Control Stations (Multiple Column)
20. 19
AGA Series Control Stations (Multiple Column)
Control Stations with Switches/Pilot Lights
Control stations are available with selected combination
of switches/pilot lights as listed below. For the dimensions
and mounting centers, see the figures below and on page
20.
Switches/Pilot Lights Mounted in Control Stations
Switch/Pilot Light Part No. Specifications
Pushbutton
PB
ABN111 * Flush, 1NO-1NC
Pilot Light
PL (Incandescent)
APN128 * Dome, 220V AC (2W)
Selector Switch
SS
ASN311 Knob, 2-position, 1NO-1NC
Meter
A
AM ammeter
(See page 38)
Specify capacity (Part No.)
Coating color of the meter
bezel: N1.5
Note: Specify a button or lens color code in place of *:
Pushbutton: B (black), G (green), R (red)
Pilot Light: G (green), R (red), W (white)
Flush pushbuttons are supplied with black, green, and red color caps.
AGA480 Control Box (Wall Mount/Pole Mount)
Package Quantity: 1
Control Box Mounted Switches/Pilot Lights
Style Part No. Symbol Part No.
NA Nameplate
Legend
4×2holes
Wall Mount
AGA4801Y
PL
PL
PB
PB
PL
PL
PB
PB
APN128R
APN128G
ABN111
ABN111
Without nameplate
Without nameplate
ON
OFFPole Mount
AGA4801SY
Wall Mount
AGAM4801Y A
PB
PB
A
PB
PB
(Note)
AM ammeter
ABN111
ABN111
Without nameplate
ON
OFF
Pole Mount
AGAM4801SY
Note: Specify the Part No. of the meter to select a required capacity.
•• Control stations with a shade are available. See page 20 for more details.
AGA580/AGA690 Control Box
(Wall Mount/Pole Mount) Package Quantity: 1
Control Box Mounted Switches/Pilot Lights
Style Part No. Symbol Part No.
NA Nameplate
Legend
5×2holes
Wall Mount
AGA5801Y
PL
PL
PB
PB
SS
PL
PL
PB
PB
SS
APN128R
APN128G
ABN111
ABN111
ASN311
Without nameplate
Without nameplate
ON
OFF
HAND-AUTO
Pole Mount
AGA5801SY
Wall Mount
AGAM5801Y
A
PL
PB
PB
A
PL
PB
PB
(Note)
AM ammeter
APN128R
ABN111
ABN111
Without nameplate
Without nameplate
ON
OFF
Pole Mount
AGAM5801SY
6×2holes
Wall Mount
AGA6801Y
PL
PB
PB
PL
PB
PL
PB
PB
PL
PB
PB PB
APN128R
ABN111
ABN111
APN128R
ABN111
ABN111
Without nameplate
ON
OFF
Without nameplate
ON
OFF
Pole Mount
AGA6801SY
Wall Mount
AGAM6801Y
A
PL
PB
PB
A
PL
PL PL
PB
PB
(Note)
AM ammeter
APN128R
APN128G
ABN111
ABN111
Without nameplate
Without nameplate
Without nameplate
ON
OFF
Pole Mount
AGAM-
6801SY
6×3holes
Wall Mount
AGA6901Y
PL
PB
PB
PL
PB
PL
PB
PB
PL
PB
PL
PB
PB
PL
PB
PB PB PB
APN128R
ABN111
ABN111
APN128R
ABN111
ABN111
Without nameplate
ON
OFF
Without nameplate
ON
OFF
Pole Mount
AGA6901SY
Wall Mount
AGAM6901Y
A
PL
PB
PB
A
PL
PL PL
PB
PB
A
PL
PL
PB
PB
(Note)
AM ammeter
APN128R
APN128G
ABN111
ABN111
Without nameplate
Without nameplate
Without nameplate
ON
OFF
Pole Mount
AGAM6901SY
Empty Enclosures Package Quantity: 1
Style 4 holes 5 holes 6 holes
Part No. AGA481Y AGA482Y AGA580Y AGA581Y AGA582Y AGA681Y AGA682Y AGA690Y AGA691Y
Shape
80
70
50
80
5075
85
80 80
70
50
80
5075
85
100
50
80
100
5075
100
160
50
160
140
Weight (Approx.) 2.6 kg 6.8 kg
•• Switch/Pilot Light Mounting Holes
31.7
4.5
ø30.5
(Meter Mounting Hole)
•• Effective Depth inside the Enclosure
(4 or 5 x 2 holes)
86
92.5
95 Front
(6 x 2 or 3 holes)
114
120
124 Front
Note: Entrance hubs HNA33YG G1 for 28mm conduit are supplied as standard. The quantity is as shown in the figure above.
•• In addition to the enclosures shown above, enclosures with a shade and pole mount enclosures are also available. See page 20 for more details.
All dimensions in mm.
21. 20
AGA Series Control Stations (Multiple Column)
Other Enclosures Package Quantity: 1
Style 4 or 5 × 2 holesSwitches/
Pilot Lights
Hubs Shade Pole
Part No.
X X X AGA4801KY AGAM4801KY − AGA5801KY AGAM5801KY
X X X AGA4801KSY AGAM4801KSY − AGA5801KSY AGAM5801KSY
X X AGA481KY AGA482KY AGA580KY AGA581KY AGA582KY
X AGA481SY AGA482SY AGA580SY AGA581SY AGA582SY
X X AGA481KSY AGA482KSY AGA580KSY AGA581KSY AGA582KSY
Shape
80
70
50
80
5075
85
80 80
70
50
80
5075
85
Weight
(Approx.)
With switches/pilot lights and a shade 5.0 kg 6.7 kg − 5.3 kg 7.0 kg
With switches/pilot lights, pole mount with a
shade
10.6 kg 12.3 kg − 10.6 kg 12.3 kg
With a shade 3.1 kg 3.1 kg 3.1 kg 3.1 kg 3.1 kg
Pole mount 8.0 kg 8.0 kg 8.0 kg 8.0 kg 8.0 kg
Pole mount with a shade 8.4 kg 8.4 kg 8.4 kg 8.4 kg 8.4 kg
Style 6 × 2 or 3 holesSwitches/
Pilot Lights
Hubs Shade Pole
Part No.
X X X AGA6801KY AGAM6801KY − AGA6901KY AGAM6901KY
X X X AGA6801KSY AGAM6801KSY − AGA6901KSY AGAM6901KSY
X X AGA681KY AGA682KY AGA690KY AGA691KY −
X AGA681SY AGA682SY AGA690SY AGA691SY −
X X AGA681KSY AGA682KSY AGA690KSY AGA691KSY −
Shape
100
50
80
100
5075
100
160 50160
140 160
5075
Weight
(Approx.)
With switches/pilot lights and a shade 11.3 kg 13.0 kg − 11.3 kg 13.8 kg
With switches/pilot lights, pole mount with a
shade
17.5 kg 19.2 kg − 17.5 kg 20.0 kg
With a shade 7.6 kg 7.6 kg 7.6 kg 7.6 kg −
Pole mount 13.0 kg 13.0 kg 13.0 kg 13.0 kg −
Pole mount with a shade 13.7 kg 13.7 kg 13.7 kg 13.7 kg −
•• For more details about enclosures without switches/pilot lights, see page 19.
•• For more detail about switches/pilot lights mounted on control stations, see page 19.
22. 21
AGA Series Control Stations (Multiple Column)
Dimensions All dimensions in mm.
AGA480/AGA580 (Wall Mount)
(35)
40
35 max.180 (Centers)
(74)
(1.2)
(152)
(290)
320
210
100
80
280(Centers) Shade
Grounding
terminal
M4
Hub
4-ø4.4 Mounting holes
Hingedside
Weight: Approx. 4.8 kg
AGA680/AGA690 (Wall Mount)
52
7
35 max.
(1.2)
(87)
(380)
(192)
300
321
295
280
380(35)
132
80 80
Shade
4-ø8 Mounting holes
Hub
Grounding
terminal
M4
Hingedside
Weight: Approx. 10.5 kg
AGA480/AGA580 (Pole Mount)
(290)
(1.2)
(74)
ø200
210 100
(150)
320
100
10
(1520)
ø230
4-ø14 Mounting holes
M6
Grounding
terminal
Shade
Hingedside
Weight: Approx. 10.2 kg
AGA680/AGA690 (Pole Mount)
(87)
(1.2)
100
380
10
(1580)
280
(380)
130
(190)
ø200
ø230
M6
Grounding
terminal
Shade
4-ø14 Mounting holes
Hingedside
Weight: Approx. 17 kg
Application Examples of Control Stations
AGA580 Control Station
Terminal block
Internal plateHingeø30 Control unit
AGA690 Control Station
Hinge Relay Timer
Terminal block
ø30 Control unit
Entrance Hub
(supplied)
HNA33 G1 for 28 mm conduit
2 column:
2 entrance hubs attached
3 column:
3 entrance hubs attached
Gland hubs for leading in
cables are also available.
Part No.
Applicable Cable
Diameter (R)
HNG31 8, 10, 12
HNAG32 13, 15, 17
HNAG33 18, 20, 22
• See page 39 for details.
23. 22
AGA Series Control Stations (Multiple Column)
Accessory (Options) Package Quantity: 1
Name Shape Part No. Description Dimensions
Enclosure Shade
152 290
74
For AGA480/AGA580
Material: Carbon steel plate
Thickness: 1 mm
Weight: Approx. 0.46 kg
AGZ-S2Y
•• Used on AGA480/AGA580 enclosures as a protection for the
switches/pilot lights against direct sunlight and falling objects.
•• Color: 5Y7/1 (semi-gloss)
•• Shade mounting hole
2-M4 Tapped hole: Depth 5
Pilot hole: Depth 5.5 max.
(no penetration)180
66
Enclosure Shade
192
380
87
For AGA680/AGA690
Material: Carbon steel plate
Thickness: 1 mm
Weight: Approx. 0.72 kg
AGZ-S3Y
•• Used on AGA680/AGA690 control boxes as a protection for
the switches/pilot lights against direct sunlight and falling
objects.
•• Color: 5Y7/1 (semi-gloss)
•• Shade mounting hole
2-M4 Tapped hole: Depth 5
Pilot hole: Depth 5.5 max.
(no penetration)250
81
Internal Plate
(195)
(300)
130
250
Dimensions in ( ) for AGA690 control box
Material: Carbon steel plate
(Zinc-plated)
Thickness: 2.3 mm
Weight: AGZ-P2: Approx. 0.59 kg
AGZ-P3: Approx. 1.05 kg
AGZ-P2
(For AGA480/AGA580)
•• Used to mount terminal blocks, relays, timers, and other units
for internal wiring.
AGZ-P3
(For AGA680/AGA690)
Stand Pole
Weight: Approx. 5.6 kg
AGZ-S205
(For AGA480/AGA580)
•• For maintenance of the pole.
•• Color: 5Y7/1 (semi-gloss)
AGZ-S205
(1005)
ø52
4-ø6.5 Hole
65
51
72
50
10
(1199)
(8to9)
94
2
1°
100
ø230
ø200
Sealing base
Grounding
terminal
Pole
Outside Dia.: ø48.6
Inside Dia.: ø44.0
Stand gasket
Base
4-ø14 Hole
(M6 × 8)
Stand Pole
Weight: Approx. 6.5 kg
AGZ-S206
(For AGA680/AGA690)
AGZ-S206 4-ø6.5 Hole
ø65
(7to8)
96
2
(1004)
(1200)
82
82
66
66
10
1º
100
ø230
ø200
Grounding
terminal
Pole
Outside Dia.: ø60.5
Inside Dia.: ø55.9
Stand gasket
Base
Sealing base
4-ø14 Hole
(M6 × 8)
All dimensions in mm.
24. 23
AGA Series Control Stations (Multiple Column)
Instructions
Precautions for Mounting AGA480/AGA580 Control
Stations on Panel
1. Insert M4 screws into the waterproof bushings at all four
corners inside the box. Push the screws with a screw-
driver and penetrate the bushings (Figure 1).
2. Thrust the screws into panel holes and secure the
screws with nuts (Figure 2).
Waterproof characteristics are not affected by piecing the
bushings with screws.
Figure 1
Box
Waterproof
Bushing
13
Figure 2
Panel surface
Ordering Information
When ordering control stations with switches/pilot
lights (standard):
Specify the Part No. of the control station.
When ordering enclosures without switches/pilot lights:
Specify the following items.
1. Part No. of the enclosure
2. Part No. and specifications of the switches/pilot lights to
be mounted (lens color, button color, etc.)
3. Nameplate
4. Lead-in fitting
Only when ordering the gland hub for leading in cables,
specify the Part No. and the cable outside diameter. (R).
5. Other specifications
Ordering Example
Part No. of Enclosure AGA581Y
Switch/Pilot
Light and
Nameplate
APN128R
APN128G
ABN210B, with NA-1
ABN201R, with NA-2
ASN311, with NA-32
Lead-in Fitting HNAG33 R18
Note: Any ø30 mm series switches/pilot lights are select-
able. Take into consideration the degree of protec-
tion of the switch/pilot light and the effective depth of
the enclosure.
25. 24
IP40 Enclosed Steel Control Stations
For ø30 mm Series Switches/Pilot Lights
Various Control Stations are Available
Various control stations are available with most widely used
combinations of switches/pilot lights (contact configurations,
voltage, button colors, and nameplates).
Specifications
Degree of Protection IP40 (IEC60529)
Material (Enclosure) Carbon steel plate (t=1.0mm)
Coating Color
(Melamine coating)
Yellow semi-gloss (Munsell 5Y7/1)
Rated Insulation
Voltage
600V (Buzzer: 250V)
Insulation
Resistance
5 MΩ minimum
Dielectric Strength
(Note 1)
Between live and dead parts:
2500V AC, 1 minute
Standard Operating
Conditions (Note 2)
Ambient temperature: -25 to +50°C (no freezing)
Relative humidity: 45 to 85% (no condensation)
Style Wall mount (1 to 5 holes)
Cable Lead-in
(Wall Mount)
Double knockouts
On top: ø22 and ø27 mm
On bottom: ø16 and ø20 mm
Applicable Switches/
Pilot Lights
IDEC ø30 mm series
Note 1: Buzzer: 2000V AC, 1 minute
Note 2: Buzzer: -10 to +40°C
Contact Ratings (Contact Block)
Contact Block
Rated Insulation Voltage 600V
Rated Thermal Current 10A
Contact Ratings by Utilization
Category IEC60947-5-1
AC-15 (A600)
DC-13 (P600)
Operational Voltage and Current by Utilization Category
Operational Voltage 24V 48V 50V 110V 220V 440V
OperationalCurrent
AC
(50/
60Hz)
AC-12 Control of
resistive loads and
solid state loads
10A — 10A 10A 6A 2A
AC-15 Control of
electromagnetic
loads (72VA)
10A — 7A 5A 3A 1A
DC
DC-12 Control of
resistive loads and
solid state loads
10A 5A — 2.2A 1.1A —
DC-13 Control of
electromagnets
5A 2A — 1.1A 0.6A —
Common
Minimum applicable load (reference value) = 3V AC/DC, 5
mA (the applicable range is subject to change according to
the operating conditions)
Rubber Bushing (Supplied) Color: Black
Enclosure
Style
Supplied Bushing Applicable
Knockout HolePart No. Outside Dia. Inside Dia.
1 or 2 holes GB-2 ø30 mm ø16 mm ø20 or ø22 mm
3 or 4 holes GB-3 ø38 mm ø20 mm ø27 mm
Switches/Pilot Lights Mounting Holes
The holes for mounting switches/pilot lights are 30.5 mm in
diameter with an anti-rotation notch. Mounting centers are
50 mm.
Double Knockouts
The top and bottom surfaces have double knockouts.
On top: ø22 and ø27 mm double knockouts
On bottom: ø16 and ø20 mm double knockouts
One rubber bushing is supplied to protect lead-in wires
from damage on the wire surface; 1- and 2-hole enclosures
are supplied with a bushing to fit ø20 and ø22 mm holes,
and 3- and 5-hole enclosures with a bushing to fit a ø27
mm hole.
ø22/ø27 mm Double Knockout
Rubber Bushing
Switch/Pilot Light
Cover Fastening
Screws
ø16/ø20 mm Double Knockout
KGN Series Control Stations
26. 25
KGN Series Control Stations
Control Stations with Switches/Pilot Lights
The control stations are available with a selected combina-
tion of switches/pilot lights as listed below. For the dimen-
sions and mounting centers, see the figures on page 26.
Switch/
Pilot Light
Part No. Specifications
Pushbutton
PB
ABN110 * Flush, 1NO
ABN101 * Flush, 1NC
ABN111 * Flush, 1NO-1NC
ABN311R ø40 mushroom, 1NO-1NC
ABBN1110 ** Flush, double beam latching, 1NO
ABBN1111 **
Flush, double beam latching,
1NO-1NC
ATN420 Toggle lever, 2NO
HN1E-BV411R Emergency stop, 1NO-1NC
Pilot Light
PL (Incandescent)
APN118 * Dome, 110V AC (2W)
APN128 * Dome, 220V AC (2W)
Selector Switch
SS
ASN311 Knob, 2-position, 1NO-1NC
ASN111 Knob, 3-position, 1NO-1NC
ASN3K11 Key, 2-position, 1NO-1NC
Buzzer
BZ
AZ11N 110V AC
AZ12N 220V AC
Note: Specify a button or lens color code in place of *:
Pushbutton: B (black), G (green), R (red)
Pilot Light: G (green), R (red), W (white)
Flush pushbuttons are supplied with black, green, and red color
caps.
Control Stations Package Quantity: 1
Control Station Mounted Switch/Pilot Light
Style Part No. Symbol Part No.
NA Nameplate
Legend
WallMount/1hole
KGN1101NY PB ABN110 ON
KGN1102NY PB ABN311R OFF
KGN1103NY PL APN118R Without nameplate
KGN1104NY PL APN128R Without nameplate
KGN1105NY SS ASN311 HAND-AUTO
KGN1106NY SS ASN111 HAND-OFF-AUTO
KGN1107NY SS ASN3K11 OFF-ON
KGN1108NY BZ AZ11N Without nameplate
KGN1110NY PB ATN420
Without nameplate
ON-OFF on bezel
KGN1111NY PB
HN1E-
BV411R
EMERGENCY
STOP
WallMount/2holes
KGN2101NY
PB
PB
ABN110
ABN101
ON
OFF
KGN2102NY
PB
PB
ABN111
ABN111
ON
OFF
KGN2103NY
PL
PL
APN118R
APN118G
Without nameplate
KGN2104NY
PL
PL
APN128R
APN128G
Without nameplate
KGN2105NY
PL
PB
APN118R
ABN111
Without nameplate
STOP
KGN2106NY
PL
PB
APN128R
ABN111
Without nameplate
STOP
KGN2107NY
PL
SS
APN118R
ASN311
Without nameplate
HAND-AUTO
Control Station Mounted Switch/Pilot Light
Style Part No. Symbol Part No.
NA Nameplate
Legend
WallMount/2holes
KGN2108NY
PL
SS
APN128R
ASN311
Without nameplate
HAND-AUTO
KGN2109NY
PL
SS
APN118R
ASN3K11
Without nameplate
OFF-ON
KGN2110NY
PL
SS
APN128R
ASN3K11
Without nameplate
OFF-ON
KGN2111NY
PB
PB
ABBN1110
ON
OFF
KGN2112NY
PB
PB
ABBN1111
ON
OFF
KGN2113NY
PB
PB
ABN110
ABN311R
ON
OFF
KGN2114NY
PL
PB
APN118R
ATN420
Without nameplate
ON-OFF on bezel
KGN2116NY
BZ
PB
AZ11N
ABN111
Without nameplate
KGN2117NY
BZ
PB
AZ12N
ABN111
Without nameplate
KGN2118NY
BZ
PL
AZ11N
APN118R
Without nameplate
KGN2119NY
BZ
PL
AZ12N
APN128R
Without nameplate
WallMount/3holes
KGN3102NY
PL
PB
PB
APN118R
ABN110
ABN101
Without nameplate
ON
OFF
KGN3103NY
PL
PB
PB
APN128R
ABN110
ABN101
Without nameplate
ON
OFF
KGN3104NY
PB
PB
SS
ABN111
ABN111
ASN311
ON
OFF
HAND-AUTO
KGN3106NY
PL
PL
PL
APN128W
APN128R
APN128G
Without nameplate
KGN3107NY
PL
PB
PB
APN118R
ABBN1110
Without nameplate
ON
OFF
KGN3108NY
PL
PB
PB
APN128R
ABBN1110
Without nameplate
ON
OFF
WallMount/4holes
KGN4101NY
PL
PL
PB
PB
APN128R
APN128G
ABN111
ABN111
Without nameplate
Without nameplate
ON
OFF
KGN4102NY
PL
PB
PB
SS
APN128R
ABN111
ABN111
ASN311
Without nameplate
ON
OFF
HAND-AUTO
27. 26
KGN Series Control Stations
Empty Enclosures Package Quantity: 1
Style Part No.
Unit
Mounting
Hole
Switch/Pilot Light
Mounting Centers
1 hole
(approx. 0.4 kg)
KGN111Y With
KGN110Y Without
2 holes
(approx. 0.5 kg)
KGN211Y With
50
KGN210Y Without
3 holes
(approx. 0.6 kg)
KGN311Y With
KGN310Y Without
4 holes
(approx. 0.7 kg)
KGN411Y With
50
KGN410Y Without
5 holes
(approx. 0.8 kg)
KGN511Y With
KGN510Y Without
Switch/Pilot Light Mounting Hole
31.7
4.5
ø30.5
70 1
Front
Accessories Package Quantity: 1
Name Part No.
Applicable
Enclosure
Applicable
Knockout Hole
Rubber Bushing
GB-2
KGN111Y
ø20 or ø22 mm
KGN110Y
KGN211Y
KGN210Y
GB-3
KGN311Y
ø27 mm
KGN310Y
KGN411Y
KGN410Y
KGN511Y
KGN510Y
Dimensions All dimensions in mm.
KGN Control Station (Wall Mount)
80 7635max.
L
37
M4 grounding terminal
M4 grounding terminalø22/ø27 double knockout
ø16/ø20 double knockout
Nameplate
(Mountingholecenters)
6-5 × 8
mounting holes
L1
60
L3
L2
(Centers)
1 hole 2 holes 3 holes 4 holes 5 holes
111Y 212Y 313Y 314Y 414Y 510Y
L 100 150 200 200 250 250
L1 50 100 150 150 200 250
L2 75 125 175 175 225 275
L3 80 130 180 180 230 280
Weight
(Approx.)
0.4 kg 0.5 kg 0.6 kg 0.6 kg 0.7 kg 0.8 kg
Instructions
Precautions for Opening the Knockout Hole
1. The metal piece for the inner hole
of ø22 or ø16 mm knockout has
two linked parts to the outer hole.
When breaking the knockout to
make an inner hole, strike the
inner metal piece at the cut parts
(the hatched parts shown as
point A at right) using a screw-
driver tip or similar tool.
2. When opening a larger hole of
ø27 or ø20 mm, first make a
smaller hole as described above.
Then break the knockout for the
larger hole using pliers.
Ordering Information
When ordering control stations with switches/pilot
lights:
Specify the Part No. of the control station.
When ordering enclosures without switches/pilot
lights:
Specify the following items.
1. Part No. of the enclosure
2. Part No. and specifications of the switche/pilot light to be
mounted (lens color, button color, etc.)
3. Nameplate
4. Other specifications
Ordering Example
Note: Any ø30 mm series switch/pilot lIghts are selectable.
However, take the effective depth inside the enclosure into
consideration.
Effective Depth inside the Enclosure
All dimension in mm
Point A
Part No. of Enclosure KGN311Y
Switch/Pilot Light
and Nameplate
APN128R
ABN210B, with NA-1
ABN201R, with NA-2
28. 27
FB Series Plastic Enclosures
IP65 lightweight plastic enclosures for
installing switches/pilot lights.
•• ø22mm switches/pilot lights can be installed.
•• Blank front enclosures, without mounting holes, are also avail
able.
•• Blank front enclosures can also be used as junction boxes to
mount terminal blocks.
•• Yellow cover version for emergency stop switches is also
available.
•• Front panel mounting, rear panel mounting, hook mounting,
and frame mounting options are available.
•• UL/c-UL listed.
Applicable Standards Mark
Certification Organization /
File No.
UL508
UL50
CSA C22.2 No. 14
CSA C22.2 No. 94
UL/c-UL listed
File No. E68961 (with mounting
hole)
•• Contact cover box (Model: FB1BR) is not UL or c-UL listed.
•• Enclosures without mounting hole is not UL or c-UL listed.
(Enclosures less than 1,639 cm3
is not approved by UL50, 2:8.)
Enclosure
Size
No. of
Mounting
Holes
Mounting Hole
Description
Cover Color Part No.
76mm
0 Without mounting hole Light beige FB1T-000Z
1 ø22mm Yellow FB1W-111Y
1 ø22mm
Light beige
FB1W-111Z
140mm
0 Without mounting hole FB2T-000Z
2
ø22mm, mounting
centers 50mm
FB2W-211Z
3
ø22mm, mounting
centers 30mm
FB2W-312Z
200mm
0 Without mounting hole FB3T-000Z
3
ø22mm, mounting
centers 50mm
FB3W-311Z
4
ø22mm, mounting
centers 36mm
FB3W-413Z
5
ø22mm, mounting
centers 30mm
FB3W-512Z
Specifications (Note 1)
Applicable
Standards
IEC/EN60529
UL508
UL50
CSA C22.2 No. 14
CSA C22.2 No. 94
Standard
Operating
Conditions
Ambient temperature: –25 to +60°C (no freezing)
Relative humidity: 45 to 85%RH (no condensation)
Storage temperature: –40 to +80°C (no freezing)
Degree of pollution: 3
Degree of
Protection
IP65 (when IP65 switches/pilot lights are installed)
NEMA Type 4X Indoor Use Only
(when Type 4X switches/pilot lights are installed)
Electric Shock
Protection
Class II (when class II switches/pilot lights are
installed)
Material
Cover/base: Polycarbonate
Cover mounting screws: Stainless steel
Applicable
Switches/Pilot
Lights
IDEC’s HW/TW/XW series and accessories
(Note 2) (Note 3)
Weight (approx.)
76mm: 125g (FB1W-111Z)
140mm: 184g (FB2W-211Z)
200mm: 243g (FB3W-311Z)
Note 1: The above specifications are for enclosures. For switches/pilot lights,
refer to the specifications of each unit.
Note 2: Choose switches/pilot lights and accessories which match the
mounting hole centers, effective depth behind the cover, and the
thickness of the cover where switches/pilot lights are installed (3
mm). Note that enclosures with 30mm or 36mm mounting hole
centers may limit the knob orientation of selector switches, because
the contact blocks can be mounted in one direction only on these
mounting centers.
Note 3: An XW series emergency stop switch of screw terminal type can be
installed on an enclosure with one mounting hole or mounting holes
of 50mm mounting centers, by connecting one clamping terminal to
one terminal pole.
Contact Cover Box
Size
No. of
Mounting
Holes
Mounting Hole
Description
Cover Color Part No.
76mm 1
ø22mm hole in
the base
Light beige FB1WR-111Z
• Cover does not have a switch/pilot light mounting hole.
• For operating instructions, see page 29.
Accessories
Description Part No. Ordering No. Package Quantity
Mounting Bracket FB9Z-PK1 FB9Z-PK1 1
DIN Rail Adapter FB9Z-PK3 FB9Z-PK3PN02 2
Mounting Hole Plug LW9Z-BP1 LW9Z-BP1 1
• For the dimensions and operating instructions, see pages 32 and 33.
• Connectors and nuts are supplied by users.
Parts Description
ø21.3 Knockout
59.5
76,140,or200
76
Cover Mounting Screws
(Stainless Steel)
ø21.3 Knockout
Switch/Pilot Light Mounting
Holes
30. 29
FB Series Plastic Enclosures
Applicable Accessories
Series Description
HW Series
Nameplate: HWAM, HWAQ, HWAS, HWAV-∗
Marking plate for nameplate: HWNP-∗
Anti-rotation ring: HW9Z-RL
EMO switch guard: HW9Z-KG3, HW9Z-KG4
Switch guard: HW9Z-K1, HW9Z-K11
Pushbutton clear boot: OC-31, OC-32
Padlock cover: HW9Z-KL1
XW Series
Emergency
Stop Switches
Nameplate: HWAV-∗
EMO switch guard: HW9Z-KG3, HW9Z-KG4
Anti-rotation ring: HW9Z-RL
TW Series
Nameplate: NWA-∗, NWAQ-∗, NWAS-0,
NWAL-0, NWAQL-0, NWAV-∗
Anti-rotation ring: OGL-31
Metal protector: OLW-C
Pushbutton clear boot: OC-31, OC-32
Button cover: OCW-10∗, OCW-11∗
Padlock cover: HW9Z-KL1, HS9Z-PC22
Note: Confirm the specifications of enclosure, switches/pilot lights, and
accessories before choosing accessories, referring to separate
catalogs.
Applicable DIN Rail
Description Material Part No.
DIN Rail
Aluminum BAA1000
Steel BAP1000
End Clip Steel BNL6
Note: Use DIN rail adapters FB9Z-PK3 when installing a DIN rail in the
enclosure. See page 32.
Applicable Terminal Block / Transformer
Series / Part No.
Terminal Block
BN-W Series: BN10W, BN15MW, BN15LW, BN30W
BA Series: BA111T, BA211T, BA311T
Separate Mounting
Transformer TWR5∗∗
Note: Install the terminal blocks and separate mounting transformers on
a DIN rail using two DIN rail adapters (FB9Z-PK3). Choose the
types and quantity of terminal blocks, transformers, end clips, and
enclosures carefully taking the specifications into consideration. The
separate mounting transformer can be installed on a DIN rail adapter
directly.
Instructions
Installation
Panel Mounting
1. Installing the FB series from the front
•• Using two M4 screws, install the base onto the panel.
Recommended tightening torque: 1.4 to 2.0 N·m
Mounting Screws (M4) 5.0 mm
(Box Thickness)
Box Base Panel
∗ Determine the screw length in consideration of the base and panel
thickness.
∗ Mounting screws are not supplied with the FB series. Use M4
mounting screws.
2. Installing the FB series from the rear
•• Insert four M4 tapped screws into holes for tapping screws on
the back of the base (depth: 8 to 10 mm, tapping screw hole
diameter: ø3.7 mm), and fasten the screws to a tightening
torque of 1.3±0.1 N·m (Nitto Seiko M4-P-TITE).
∗ Mounting screws are not supplied with the FB series. Use M4
tapping screws (recommended screws: Nitto Seiko M4-P-TITE).
∗ The value of the recommended tightening torque has been
confirmed with a M4 tapping screw (Nitto Seiko M4-P-TITE).
When using other screws, check that the tapping screw hole is not
damaged and the screw can be securely tightened.
3. Installation using mounting bracket FB9Z-PK1
•• Refer to installation instructions on page 31.
Installing and Removing the Switch/Pilot Light
•• Refer to installation instructions for each unit.
Installing the Safety Lever Lock for HW Series
(HW9Z-LS, yellow)
When installing the HW series in the direction shown below,
install the safety lever lock with the lever in the unlocked posi
tion, lock the lever, and push in the safety lever lock.
Safety Lever Lock
1
2
3
Installing the Cable Gland
•• Break a desired knockout to mount a cable
gland using a hammer and a screwdriver, and
install the cable gland.
∗ When breaking the knockout to make a cable gland
hole, be careful not to damage the internal contact
block.
∗ Note that cracks or burrs on the cable gland hole will
degrade the waterproof characteristics.
31. 30
FB Series Plastic Enclosures
Instructions
Installing the Cover and Base
•• Attach the cover to the base so that the TOP mark on the
cover and base are in the same direction.
•• Use cover mounting screws to attach the cover to the base.
(Recommended tightening torque: 1.3±0.1 N·m)
TOP
TOP
TOP
Marking
(Cover) (Base)
∗ Make sure that the cover and the base are attached in the correct
direction. Otherwise, the FB series may be damaged.
Installation using tapping screw hole inside the enclosure
•• When using M3 tapping hole screws inside the enclosure, make
sue to install the devices in consideration of the insulation dis-
tance and temperature rise. Damages caused by using devices
other than those specified by IDEC are excluded from any war-
ranty. Ensures installed with devices using tapping screw holes
will not be UL or c-UL listed.
•• M3 tapping screw hole (depth: 6 to 7mm, tapping screw hole
diameter ø2.7m)
•• Recommended tightening torque: 0.9 ±0.1 N·m, M3-P-TITE (Nitto
Seiko)
Applicable Crimping Terminal
HW/TW Series
20.2 max.
Applicable Crimping Terminal
Insulating Tube
Wire
6.0 min.
ø3.6 min.
4.0 max.
20.2 max
W
ø3.6 min.
4.0 max. 6.0 min.
W
A A
B
W dimensions
Direction of A: 8.0 maximum
Direction of B: 6.6 maximum
A A
B B
B
Non-insulated Terminal
Insulated Terminal
ø3.6 min.
4.0 max. 6.0 min.
6.0 min.
20.2 max.
W
Applicable Crimping Terminal
Insulating Tube
Wire
XW Series (Screw Terminal)
18.3 max.
4.7 to 5.9
Applicable Crimping Terminal
Insulating Tube
Wire
ø3.2 min.
6.0 max.
4.7 min.
(Note)
14.9 max.
3.0 max.
ø3.2 min.
14.9 max.
3.0 max. 4.7 to 5.9
6.0 max.
Non-insulated Terminal
Insulated Terminal ∗ When a spade terminal is used, the
dimension is 4.7 to 5.9 mm.
∗ Be sure to install an insulating tube
on the crimping terminal.
∗ When using crimping terminals
for the XW series, use only one
crimping terminal for each terminal.
∗ Make sure that the wiring does not
contact the enclosure.
Applicable Cable Gland
•• Use cable glands with waterproof characteristics (IP65, TYPE
4X) which can be mounted on a panel thickness of 3 mm or
more.
M20, G1/2, PG13.5
10 mm max. 30 mm
max.
Box Base
Locking ring for Cable Gland
3 mm All dimensions in mm.
∗ Cable gland and Locking nuts are not attached.
1. When using plastic cable gland, metal cable gland and multi-core
cable
Gland Port Size Plastic Cable Gland
M20
5311 1220 [Skintop-ST-M]
Applicable gasket: GPM20 (LAPP, Germany)
G1/2
5380 6030 [Skintop-ST-PF]
Applicable gasket: GP 050 (LAPP, Germany)
PG13.5
5301 5030 [Skintop-ST]
Applicable gasket: GP13.5 (LAPP, Germany)
2. Locking nut for installing the cable gland
Gland Port Size Locking Nut Part No. (made of plastic)
M20 HW9Z-NM20 (IDEC)
G1/2 HW9Z-G (IDEC)
PG13.5 HW9Z-PG135 (IDEC)
•• The degree of protection of the cable gland examples de-
scribed above is not NEMA TYPE 4X.
•• When using the FB plastic enclosures in North America, be
sure to use UL approved plastic cable glands.
•• Tighten cable glands to a torque of 3.0±0.3 N·m.
∗ Insufficient tightening of the cable gland may degrade the waterproof
characteristics.
∗ Electric shock protection Class II is maintained only when a plastic
cable gland is used.
•• Determine the cable gland for a multi-core cable according to
the outside diameter of the cable sheath.
•• When wiring from the back of FB series, use the ø14 knock-
out on the back of the enclosure. A cable gland cannot be
installed to the ø14 knockout.
32. 31
FB Series Plastic Enclosures
Instructions
Notes
Applicable Wire Size
•• Determine the wire size in consideration of the applicable wire
for switches/pilot lights and the applicable diameter of cables.
Wiring
•• Avoid foreign objects such as dust, liquid, and oil from enter-
ing the switch while connecting a conduit or wiring.
•• Do not twist or pull the cable of flexible conduit with excessive
force. Otherwise, the wire, FB series, and switches/pilot lights
may be damaged.
•• Because the FB series is not provided with a PG terminal,
bonding circuits cannot be interconnected.
Installation of switches/pilot lights on 30mm centers
•• When mounting HW/TW series control
units on 30mm mounting centers
(close mounting), make sure to use a
barrier (optional: HW-VG1) to secure
the insulation properties of the termi-
nal. The barriers (HW-VG1) can be
easily pressed into the side of the
contact block.
Operation
•• Avoid any contact with oil or coolants.
Otherwise, the enclosure may be damaged.
•• Use the FB series for INDOOR applications only.
Contact Cover Box
Specifications, applicable units, and wiring
•• Same as the standard enclosures.
Installing XW series to the FB1WR-111Z contact cover
•• Remove the contact block and the locking ring from the
operator and check that the rubber gasket is in place. Insert
the operator from panel front into the panel hole. Attach the
rubber gasket and the base to the operator unit (place the
rubber gasket between the panel and the base) and tighten
the locking ring using locking ring wrench MW9Z-T1. Recom-
mended tightening torque: 2.0 N·m
•• Attach the contact block to the operator. After wiring, attach
the cover to the base using four cover mounting screws. Rec
ommended tightening torque: 1.3±0.1 N·m
•• Use a nameplate if necessary.
•• Determine the panel thickness by excluding the thickness of
the base (2.0 mm) and accessories (if used) from the maxi
mum panel thickness for the switcs/pilot light.
Panel
Nameplate
Base
Cover
Contact Block
Rubber Gasket (supplied)
Locking Ring
Rubber Gasket
Operator
•• Do not expose the cable to excessive force, otherwise fail-
ure or damage may be caused. When mounting strength
is needed, insert M4 tapping screws from the front of the
panel (screw tightening depth: 8 to 10mm tapping screw hole:
ø3.7mm)
•• Determine the mounting hole centers referring to the dimen
sions of the plastic enclosures on page 28.
Mounting Bracket
Hook Mounting
•• Attach the FB9Z-PK1 mounting bracket on the FB series with
the supplied screws (two M4 tapping screws).
Recommended tightening torque: 1.3±0.1 N·m
•• Do not tighten the FB9Z-PK1 onto the FB series with exces
sive force. The tapping screw hole may be damaged and may
not securely hold the enclosure.
•• When using the FB9Z-PK1 as hook mounting brackets, make
sure that vibrations or shocks do not cause the enclosure to
fall off, and that the switch/pilot light operates properly.
•• Make sure that the mounting strength is secured.
FB9Z-PK1
Two M4 Tapping Screw Holes
Two M4 Tapping Screws (supplied)
Frame Mounting
•• The FB9Z-PK1 can be used as frame mounting brackets by
attaching two FB9Z-PK1 as shown below.
FB9Z-PK1
Two M4 Tapping
Screws (supplied)
Four M4 Tapping Screw Holes
•• Attach the FB9Z-PK1 on the FB series with the supplied
screws (two M4 tapping screws).
Recommended tightening torque: 1.3±0.1 N·m.
•• Do not tighten the FB9Z-PK1 onto the FB series with exces
sive force. The tapping screw hole may be damaged and may
not securely hold the enclosure.
•• Using two M6 screws, fasten the FB9Z-PK1 securely on the
frame.
Recommended tightening torque: 5.0±0.3 N·m
∗ M6 mounting screws and nuts are not supplied with the FB9Z-PK1.
∗ The value of the recommended tightening torque for M6 screws has been
confirmed with a hexagon socket head screw. When other screws are
used and tightened to a smaller torque, make sure that the screws do not
become loose after mounting.
M6 Screw
Frame
FB9Z-PK1 Nut
•• Do not expose the FB series to excessive force, otherwise
failure or damage may be caused.
•• Make sure that the mounting strength is secured in consider
ation of the operation of switch/pilot light.
30
Barrier
(optional, HW-VG1)
33. 32
FB Series Plastic Enclosures
Dimensions
72
36
30
6.6
10.5
54
6.5
13
2
10
R4
R2.5
R3.3
L
76
A
B28
59.5 10
Mounting Hole
FB Series Enclosure
FB1 FB2 FB3
L 76 140 200
A 19 18.5 18.5
B 12.5 12 12
76
M6 ScrewI36
C
L
D
28
I Adjustable range
59.5 10
FB Series Enclosure
FB1 FB2 FB3
L 76 140 200
C 93 156 216
D 114 177 237
Frame Mounting
All dimensions in mm.
FB9Z-PK1
Hook Mounting
DIN Rail Adapter
Installing the FB9Z-PK3 DIN Rail Adapter
•• To attach the FB9Z-PK3 on the FB series, position the positioning
hole of the FB9Z-PK3 with the positioning boss in the enclosure
using four M3 tapping screws (supplied) as shown in the figure
below. Recommended tightening torque: 0.9±0.1 N·m
•• Do not tighten the FB9Z-PK3 onto the FB series with excessive
force. The tapping screw hole may be damaged and may not
securely hold the enclosure.
Installing the DIN Rail
•• To attach a DIN rail, use plain washers and spring washers on
two M5 screws and tighten firmly.
Recommended tightening torque: 2.0±0.1 N·m
•• DIN rail mounting screw (M5)
Screw length: (spring washer thickness + plain washer thickness
+ DIN rail thickness) + 3 to 5 mm
Positioning Boss
FB9Z-PK3
Positioning Hole
Two M5 Screws
(including spring
washer and plaing
washer)
Four M3 Tapping
Screws (supplied)
DIN Rail
34. 33
FB Series Plastic Enclosures
•• M5 screws, spring washers, and plain washers are not supplied.
•• The length of DIN rail must be within the effective internal dimen
sions.
•• Do not tighten the M5 screw onto the FB9Z-PK3 with excessive
force. The screw hole may be damaged and may not securely
hold the FB9Z-PK3.
M5 Screw
DIN Rail
Spring WasherPlain Washer
M5ScrewLength
SpringWasherThickness
+PlainWasherThickness
DINRail
Thickness
Mounting Switches/Pilot Lights on DIN Rail
•• Refer to each instruction sheet.
Installing the Separate Mounting Transformer
•• After attaching the FB9Z-PK3 on the FB series, attach the sepa
rate mounting transformer on the FB9Z-PK3, using plain washers
and spring washers on two M3 screws as shown in the figure
below. Recommended tightening torque: 0.5 to 0.8 N·m
Two M3 Screws
Two Spring Washers
Two Plain Washers
Separate Mounting
Transformer
FB9Z-PK3
•• Separate mounting transformer mounting screw (M3)
Screw Length: (Spring washer thickness) + (Plain washer thick
ness) + 7 to 10 mm
•• M3 screws, spring washers, and plain washers are not supplied.
•• Do not tighten the screw with excessive force.
The screw hole and the separate mounting transformer may be
damaged.
Spring Washer
Plain Washer
FB9Z-PK3
M3
Screw
Separate Mounting
Transformer
M3ScrewLength
SpringWasherThickness
+PlainWasherThickness
FB9Z-PK3 Dimensions
66
40
29
22
12.52
2-M3
2-M5
45
B
46
A
Inside Dimensions of
FB Series Enclosure
FB9Z-PK3
Installation Positions
FB Series Enclosure
FB2 FB3
A 50 112.5
B — 37.5
See internal dimensions on page 28.
All dimensions in mm.
Other Precautions
•• Rated current of terminal blocks depends on operating conditions
such as wire type, number of bundle wires, and ambient tempera
ture. Check the specifications of terminal blocks carefully, and use
terminal blocks within the specification values. Otherwise electric
shock or fire hazard may be caused.
•• FB series is rated as Class II protection against electric shock
(no reliance on installation protective measures, according to IEC
61140). When using a blank front enclosure as a junction box and
grounding is necessary, provide appropriate grounding, for exam
ple installing a grounding terminal block inside the enclosure.
•• For wiring, refer to the instructions of the FB series enclosures
and switches/pilot lights used.
35. 34
IP65 Waterproof Stainless Steel Control Stations
High Corrosion and Weather Resistant
The AGS series control stations are designed for mounting
various types of switches/pilot lights in various combinations.
Standard control stations are available with predetermined
specifications of cable lead-in holes and switches/pilot lights
mounted (contact configurations, voltage, button colors, and
nameplates).
•• Wide variety of combinations of switches/pilot lights are pos-
sible. Select from a wide variety of ø30 series switches/pilot
lights.
•• Buff finish available upon request.
Specifications
Degree of Protection
(Note 1)
IP65 (IEC60529)
Key selector switch: Splash-proof IP54
Material (Box) Stainless steel plate (thickness 1 mm)
Coating Color
(Melamine coating)
Yellow semi-gloss (Munsell 5Y7/1)
1 column: Outside only
2 or 3 column: Both inside and outside
Rated Insulation
Voltage
600V
Insulation Resistance 5 MΩ minimum (500V DC megger)
Dielectric Strength
(Note 2)
Between live and dead parts:
2500V AC, 1 minute
Standard Operating
Conditions
Ambient temperature: -25 to +50°C (no freezing)
Relative humidity: 45 to 85% (no condensation)
Enclosure Style
1 to 5 holes × 1 column,
3 to 5 holes × 2 or 3 columns
Wall mount/Pole mount
Cable Lead-in
(Wall Mount)
Reducer bushing (Gland hub also available)
G1 (28 mm)
1 to 3 holes × 1 column: G3/4 (22 mm)
Applicable Switches/
Pilot Lights
IDEC ø30 mm series, AM ammeter
(except enclosed type units)
Note 1: Degree of protection depends on the switches/pilot lights mounted
on the enclosure. When IP65 switches/pilot lights are mounted, the
entire control station has IP65 characteristics. (See page 2)
Note 2: AM ammeter: 2000V AC, 1 minute
Switch/Pilot Light Mounting Holes
The holes for mounting switches/pilot lights are 30.5 mm in diam-
eter with an anti-rotation notch. Mounting centers are 50 mm.
Lead-in Fittings (Wall Mount)
A reducer bushing made of brass is supplied for connecting a
steel conduit to lead in cables.
1 column × 1 to 3 holes: With one G3/4 for 22 mm conduit
1 column × 4 or 5 holes: With one G1 for 28 mm conduit
2 columns × 2 or 3 holes: With two G3/4 for 22 mm conduit
2 columns × 4 or 5 holes: With two G1 for 28 mm conduit
3 columns × 2 or 3 holes: With three G3/4 for 22 mm conduit
3 columns × 4 or 5 holes: With three G1 for 28 mm conduit
Note: Mounting other than standard (e.g. one bushing for 2 column, one
or two bushings for 3 column) Is not available. In this case, a plug is
supplied.
HNG gland hubs for lead in cables are also available.
Stand Pole (Pole Mount)
The pole is made of carbon steel pipe, and the base is made of
cast iron. The coating color is the same as the enclosure, yellow
(semi-gloss).
Pole
Base
Stainless
Steel Screws
Reducer Bushing
Enclosure
Switch/
Pilot Light
AGS Series Control Stations
36. 35
AGS Series Control Stations
Control Stations with Switches/Pilot Lights
The standard control stations are available with selected combi-
nations of switches/pilot lights as listed below. For the dimensions
and mounting centers, see the figures on page 37.
Switches/Pilot Lights Mounted on Standard Control Stations
Switch/Pilot Light Part No. Specifications
Pushbutton
PB
ABN110 * Flush, 1NO
ABN101 * Flush, 1NC
ABN111 * Flush, 1NO-1NC
ABN311R ø40 mushroom, 1NO-1NC
ATN420 Toggle lever, 2NO
HN1E-BV411R Emergency stop, 1NO-1NC
Pilot Light
PL (Incandescent)
APN118 * Dome, 110V AC (2W)
APN128 * Dome, 220V AC (2W)
Selector Switch
SS
ASN311 Knob, 2-position, 1NO-1NC
ASN111 Knob, 3-position, 1NO-1NC
ASN3K11 Key, 2-position, 1NO-1NC
Meter
A
AM ammeter
(See page 38)
Specify capacity (Part No.)
Coating color of the meter
bezel: N1.5 (polish)
Note: Specify a button or lens color code in place of *:
Pushbutton: B (black), G (green), R (red)
Pilot Light: G (green), R (red), W (white)
Flush pushbuttons are supplied with black, green, and red color caps.
1-column Package Quantity: 1
Control Station Mounted Switches/Pilot Lights
Style Part No. Symbol Part No.
NA Nameplate
Legend
WallMount/1hole
AGS1101M PB ABN110 ON
AGS1102M PB ABN311R OFF
AGS1103M PL APN118R Without nameplate
AGS1105M SS ASN311 HAND-AUTO
AGS1106M SS ASN111 HAND-OFF-AUTO
AGS1107M * SS ASN3K11 OFF-ON
AGS1108M PB ATN420
Without nameplate
ON-OFF on bezel
AGS1111M PB
HN1E-
BV411R
EMERGENCY
STOP
PoleMount/
1hole
AGS1101SM PB ABN110 ON
AGS1102SM PB ABN311R OFF
AGS1111SM PB
HN1E-
BV411R
EMERGENCY
STOP
WallMount/2holes
AGS2101M
PB
PB
ABN110
ABN101
ON
OFF
AGS2102M
PB
PB
ABN111
ABN111
ON
OFF
AGS2103M
PL
PL
APN118R
APN118G
Without nameplate
AGS2104M
PL
PL
APN128R
APN128G
Without nameplate
Degree of protection marked with * is splash-proof IP54.
Control Station Mounted Switches/Pilot Lights
Style Part No. Symbol Part No.
NA Nameplate
Legend
WallMount/2holes
AGS2105M
PL
PB
APN118R
ABN111
Without nameplate
STOP
AGS2106M
PL
PB
APN128R
ABN111
Without nameplate
STOP
AGS2107M
PL
SS
APN118R
ASN311
Without nameplate
HAND-AUTO
AGS2108M
PL
SS
APN128R
ASN311
Without nameplate
HAND-AUTO
AGS2110M *
PL
SS
APN128R
ASN3K11
Without nameplate
OFF-ON
AGS2113M
PB
PB
ABN110
ABN311R
ON
OFF
AGS2115M
PL
PB
APN128R
ATN420
Without nameplate
ON-OFF on bezel
PoleMount/
2holes
AGS2101SM
PB
PB
ABN110
ABN101
ON
OFF
AGS2107SM
PL
SS
APN118R
ASN311
Without nameplate
HAND-AUTO
WallMount/3holes
AGS3102M
PL
PB
PB
APN118R
ABN110
ABN101
Without nameplate
ON
OFF
AGS3103M
PL
PB
PB
APN128R
ABN110
ABN101
Without nameplate
ON
OFF
AGS3104M
PB
PB
SS
ABN111
ABN111
ASN311
ON
OFF
HAND-AUTO
AGS3105M
PL
PL
PL
APN118W
APN118R
APN118G
Without nameplate
AGS3106M
PL
PL
PL
APN128W
APN128R
APN128G
Without nameplate
PoleMount/3holes
AGS3102SM
PL
PB
PB
APN118R
ABN110
ABN101
Without nameplate
ON
OFF
AGS3104SM
PB
PB
SS
ABN111
ABN111
ASN311
ON
OFF
HAND-AUTO
Degree of protection marked with * is splash-proof IP54.
37. 36
AGS Series Control Stations
Control Station Mounted Switches/Pilot Lights
Style Part No. Symbol Part No.
NA Nameplate
Legend
Wall•Pole/4holes
Wall Mount
AGS4101
PL
PL
PB
PB
APN128R
APN128G
ABN111
ABN111
Without nameplate
Without nameplate
ON
OFFPole Mount
AGS4101S
Wall Mount
AGSM4101 A
PB
PB
(Note )
AM ammeter
ABN111
ABN111
Without nameplate
ON
OFFPole Mount
AGSM4101S
Wall Mount
AGS4102
PL
PB
PB
SS
APN128R
ABN111
ABN111
ASN311
Without nameplate
ON
OFF
HAND-AUTOPole Mount
AGS4102S
Wall•Pole/5holes
Wall Mount
AGS5101
PL
PL
PB
PB
SS
APN128R
APN128G
ABN111
ABN111
ASN311
Without nameplate
Without nameplate
ON
OFF
HAND-AUTOPole Mount
AGS5101S
Wall Mount
AGSM5101 A
PL
PB
PB
(Note)
AM ammeter
APN128R
ABN111
ABN111
Without nameplate
Without nameplate
ON
OFFPole Mount
AGSM5101S
Note: Specify the Part No. of the meter to select a required capacity.
2-column Package Quantity: 1
Control Station Mounted Switches/Pilot Lights
Style Part No. Symbol Part No.
NA Nameplate
Legend
Wall•Pole/3holes
Wall Mount
AGS3801
PB
PB
SS
PB
PB
SS
ABN111
ABN111
ASN311
ON
OFF
HAND-AUTOPole Mount
AGS3801S
Wall Mount
AGS3802
PL
PB
PB
PL
PB
PB
APN128R
ABN111
ABN111
Without nameplate
ON
OFFPole Mount
AGS3802S
Wall•Pole/
4holes
Wall Mount
AGS4801 PL
PL
PB
PB
PL
PL
PB
PB
APN128R
APN128G
ABN111
ABN111
Without nameplate
Without nameplate
ON
OFFPole Mount
AGS4801S
Wall•Pole/5holes
Wall Mount
AGS5801
PL
PL
PB
PB
SS
PL
PL
PB
PB
SS
APN128R
APN128G
ABN111
ABN111
ASN311
Without nameplate
Without nameplate
ON
OFF
HAND-AUTO
Pole Mount
AGS5801S
Wall Mount
AGSM5801
A
PL
PB
PB
A
PL
PB
PB
(Note)
AM ammeter
APN128R
ABN111
ABN111
Without nameplate
Without nameplate
ON
OFF
Note: Specify the Part No. of the meter to select a required capacity.
3-column Package Quantity: 1
Control Station Mounted Switches/Pilot Lights
Style Part No. Symbol Part No.
NA Nameplate
Legend
Wall•Pole/3holes
Wall Mount
AGS3901
PB
PB
SS
PB
PB
SS
PB
PB
SS
ABN111
ABN111
ASN311
ON
OFF
HAND-AUTOPole Mount
AGS3901S
Wall Mount
AGS3902
PL
PB
PB
PL
PB
PB
PL
PB
PB
APN128R
ABN111
ABN111
Without nameplate
ON
OFFPole Mount
AGS3902S
Wall•Pole/
4holes
Wall Mount
AGS4901 PL
PL
PB
PB
PL
PL
PB
PB
PL
PL
PB
PB
APN128R
APN128G
ABN111
ABN111
Without nameplate
Without nameplate
ON
OFFPole Mount
AGS4901S
Wall•Pole/5holes
Wall Mount
AGS5901
PL
PL
PB
PB
SS
PL
PL
PB
PB
SS
PL
PL
PB
PB
SS
APN128R
APN128G
ABN111
ABN111
ASN311
Without nameplate
Without nameplate
ON
OFF
HAND-AUTOPole Mount
AGS5901S
Wall Mount
AGSM5901 A
PL
PB
PB
A
PL
PB
PB
A
PL
PB
PB
(Note)
AM ammeter
APN128R
ABN111
ABN111
Without nameplate
Without nameplate
ON
OFFPole Mount
AGSM5901S
Note: Specify the Part No. of the meter to select a required capacity.
Ordering Information
When ordering control stations with switches/pilot lights:
Specify the Part No. of the control station.
When ordering enclosures without switches/pilot
lights, specify the following items.
1. Part No. of the enclosure
2. Part No. and specifications of the switches/pilot lights to
be mounted (lens color, button color, etc.)
3. Nameplate
4. Lead-in fitting
Only when ordering the gland hub for leading in cables,
specify Part No. and the cable outside diameter (R).
5. Other specifications
Ordering Example
Part No. of Enclosure AGS
Switch/Pilot
Light and
Nameplate
APN128R
APN126G
ABN210B, with NA-1
ABN201R, with NA-2
ASN311, with NA-32
Note: Any ø30 mm series switches/pilot lights are select-
able. Take into consideration the degree of protection
of the switch/pilot light and the effective depth of the
enclosure.
38. 37
AGS Series Control Stations
Empty Enclosures Package Quantity: 1
Style 1 column × 1 or 2 holes 1 column × 3 holes 1 column × 4 or 5 holes
Part No.
Coating AGS210M AGS211M AGS212M AGS310M AGS311M AGS411 AGS510 AGS511
Buffing AGS210M-BUFF AGS211M-BUFF AGS212M-BUFF AGS310M-BUFF AGS311M-BUFF AGS411-BUFF AGS510-BUFF AGS511-BUFF
Shape
50
50
50
50
Weight (Approx.) 1.2 kg 1.6 kg 2.4 kg
Style 2 columns × 3 holes 2 columns × 5 holes 3 columns × 3 holes 3 columns × 5 holes
Part No.
Coated AGS380 AGS381 AGS580 AGS581 AGS390 AGS391 AGS590 AGS591
Buff AGS380-BUFF AGS381-BUFF AGS580-BUFF AGS581-BUFF AGS390-BUFF AGS391-BUFF AGS590-BUFF AGS591-BUFF
Shape
70 50
70
50
140
50
140
50
Weight (Approx.) 3.8 kg 4.6 kg 4.8 kg 6.5 kg
• Switch/Pilot Light Mounting Holes
31.7
4.5
ø30.5
(Meter Mounting Hole)
ø65.5
• Effective Depth inside the Enclosure
(From the lid surface to the inside bottom)
* AGS210, 310: 104
* AGS210M, 310M: 104
* AGS510: 105
(1-column)
1104
(2- or 3-column)
1105
Dimensions All dimensions in mm.
1 hole 2 holes 3 holes 4/5 holes
H 1320 1370 1500
Weight
(Approx.)
Wall Mount 1.2 kg 1.6 kg 2.4 kg
Pole Mount 6.8 kg 7.2 kg 8.0 kg
2-, 3-, 4- or 5-hole × 2 columns
36.5
35B
106
70
220
230
210
B
A
106 2
35
36.5
300
310
320
70 70
A
2
(Lead in position)
3–G
M4
grounding
terminal
M4
grounding
terminal
2–G
(Lead in position)
4-ø10
Mounting
hole
4-ø10
Mounting
hole
2-column 3-column
2 holes 3 holes 4 holes 5 holes 2 holes 3 holes 4 holes 5 holes
A 250 350 50 350
B 180 280 180 280
H 1400 1500 1400 1500
G 3/4 (22 mm) 1 (28 mm) 3/4 (22 mm) 1 (28 mm)
Weight
(Approx.)
Wall Mount 3.8 kg 4.6 kg 4.8 kg 6.5 kg
Pole Mount 9.3 kg 10.4 kg 10.6 kg 12.2 kg
All dimensions in mm.
H
ø200
ø230
10
M6
Grounding
terminal
4-ø14 mounting hole
ø200
H
ø230
10
M6
Grounding
terminal
4-ø14 mounting hole
1- or 2-hole × 1 column
35
115
110
95
106 1.5
100
142
170
9
36
G3/4
M4 Grounding terminal
4-M5×12
(W/SW sems)
Hinge
4-ø7
(Mounting
hole)
3-hole × 1 column 4- or 5-hole × 1 column
9192
150
220
36
1.5106
35
95
110
115
G3/4
4-ø7
(Mounting
hole)
Hinge 4-M5×12
(W/SW sems)
M4 Grounding terminal
4-ø7
Mounting
hole
M4
Grounding
terminal
G1
(28mm)
95
115 1.5106
350
36
25050
110
2-, 3-, 4- or 5-hole × 3 columns
39. 38
AC Ammeter
Class 2.5, IP65/jetproof AC ammeter
•• Double expanded scale
•• For measuring higher than 10A, use a current transformer.
•• Can be used with AGA/AGS control stations.
Package quantity: 1
Appearance Capacity Part No. Dimensions (mm)
5A AM21B
M6 screw
M65 P1.5
54 27
81
ø74
Panel thickness: 18 maximum
ø65.5
Panel cut-out
10A AM22B
15A AM23B
30/5A AM24CB
60/5A AM25CB
100/5A AM26CB
150/5A AM27CB
200/5A AM28CB
300/5A AM29CB
/5A AM2CB
Specifications
Degree of Protection
IP65 (IEC 60529), jetproof
(when installed on IP65 control station)
Housing color Munsell N1.5 (melamine gloss coating)
Insulation Resistance 10MΩ minimum (500V DC megger)
Dielectric Strength
1000V AC, 1 minute (between live and
dead parts)
Operating
Temperature
–25 to +50°C (no freezing)
Operating Humidity 45 to 85% (no condensation)
Instructions
1. For measuring higher than 10A, use a current transformer.
2. The ammeter cover can be removed easily to set the pointer to
zero.
Ordering Information
Specify the Part No.
When the capacity other than listed in the above table is required,
specify the current as shown below.
When 50A is required:
AM2C50AB
40. 39
Lead-in Fittings
Entrance Hub (For Connecting Conduit)
Made of aluminum alloy die-cast (supplied with a locking nut)
HN
SW2 SW1
A
D
B
C
M N
FE
L
SW2 SW1
A
D
B
C
M N
FE
LHNA
Made of cast iron (supplied with a locking nut and a bushing)
Package Quantity: 1
Material Part No.
Applicable
Conduit
Thread Size Outside Dimensions (mm)
A (male) B (female) C D E F L M N SW1 SW2
Aluminum
HNA22 22 mm G3/4 G3/4 18 32 15 31 46 7 18 32 33
HNA33 28 mm G1 G1 23 38 16 35 51 7 23 38 41
Iron
HN21 16 mm G3/4 G1/2 13 26 23 27 50 9 21 26 33
HN22 22 mm G3/4 G3/4 18 32 23 36 59 9 22 32 33
HN31 16 mm G1 G1/2 13 26 23 23 46 6 21 26 41
HN32 22 mm G1 G3/4 18 32 23 30 53 6 22 32 41
HN33 28 mm G1 G1 23 38 23 41 64 6 25 38 41
Gland Hub (For Lead in Cable)
Made of aluminum alloy die-cast (supplied with a locking nut)
HNAG
SW2 SW3SW1
A
D
C
M
E F
L
Made of cast iron (supplied with a locking nut and a bushing)
HNG
SW2 SW1 SW3
A
C
M
E
D
F
L
Package Quantity: 1
Material Part No. Applicable Cable Diameter (R)
Thread
Size
Outside Dimensions (mm)
A C D E F L M SW1 SW2 SW3
Die-cast
aluminum
HNAG22R * 13, 15, 17
The tolerance of cable diameter
is +0 to -2 mm
(Example)
When R = 15, the applicable
cable outside diameter is
ø13 to 15 mm.
G3/4 18 32 15 47 62 7 32 33 29
HNAG33R * 18, 20, 22 G1 23 38 16 53 69 7 38 41 35
Cast iron
HNG21R * 8, 10, 12 G3/4 13 26 23 39 62 9 26 33 23
HNG22R * 13, 15, 17 G3/4 18 32 23 48 71 9 32 33 29
HNG31R * 8, 10, 12 G1 13 26 23 35 58 6 26 41 23
HNG32R * 13, 15, 17 G1 18 32 23 42 65 6 32 41 29
HNG33R * 18, 20, 22 G1 23 38 23 54 77 6 38 41 35
SW1: Hub size across flats
SW2: Locking nut size across flats
SW3: Gland size across flats
SW1: Hub size across flats
SW2: Locking nut size across flats
Note: Standard coating color: Yellow semi-gloss (melamine coating)
Note 1: Specify an applicable cable diameter code in place of *.
Note 2: Standard coating color: Yellow semi-gloss (melamine coating)
Note 3: Material of gland: Brass (nickel-plated surface)
Note 4: When ordering, specify the Part No.
For example, when ordering the HNG21 with an applicable cable diameter of ø10, specify HNG21R10.
Control Station Accessories