The SITRANS P Z pressure transmitter measures gauge pressure using a thin-film strain gauge mounted on a ceramic diaphragm. It has a brass housing, ceramic measuring cell, and electrical connection via a M16 x 1.5 plug. It measures pressures from 0-16 or 0-25 bar with 0.5% accuracy, has a 4-20mA output, and is used to measure gases, liquids, and vapors in various industrial applications like power, mechanical engineering, and shipping.
The SITRANS P Z pressure transmitters measure gauge and absolute pressure as well as liquid and gas levels. They have a stainless steel housing and ceramic measuring cell that is temperature compensated. They are designed for use in various industries and can measure pressure of liquids, gases, and vapors in ranges from 0-400 bar or 0-6000 psi. They produce a 4-20 mA or 0-10 V DC output signal proportional to the measured pressure.
The SITRANS P250 transmitter measures the differential pressure of liquids and gases using a piezo-resistive measuring cell. It has a sturdy stainless steel enclosure and provides high measuring accuracy for use in various industries. The transmitter outputs a 4-20 mA or 0-5/10 VDC signal linearly proportional to the measured differential pressure. It is suitable for static and dynamic pressure measurements of gases and liquids.
1) Bossmanfilter BWC-Series water cooled aftercoolers use cooling water to lower the temperature of hot compressed air from an air compressor, allowing up to 63% of water in the air to be removed.
2) In a counter-flow heat exchanger, fluids flow in opposite directions to maximize heat transfer from the air to the cooling water.
3) The aftercoolers have applications in a wide range of industries, including manufacturing, food/beverage processing, and more.
In industrial practice, the precision of the measurement technology used is of increasing significance. This is especially the case where the accuracy of the measuring instruments is tested: in calibration. However, not all pressure or differential pressure calibrations can be carried out in a laboratory – the deinstallation of the test object is often not possible, for instance.
The Pneumator fulfils both requirements: it can be used not only for stationary applications (in a laboratory), but also as a mobile calibrator. In addition to this, it also serves as a precision
measuring instrument on site, combining highest accuracy with reliable battery operation.
The document describes the T600xxx-3 Series thermostats, which provide temperature control for heating and cooling equipment. The thermostats come in both non-programmable and programmable models for single-stage, heat pump, multi-stage, and economizer applications. Key features include an LCD display, simplified setpoint adjustment, configurable parameters, and compatibility with remote sensors. The thermostats use a proportional control algorithm to regulate temperature and include specifications for power, inputs, outputs, temperature range, accuracy, and dimensions.
The document summarizes information about Gardner Denver screw compressors ranging from 22-90 kW. It provides details on the ENDURO air ends, control unit, easy installation, low maintenance costs, base components, and the product range. Maintenance is designed to be easy via removable panels and a limited number of moving parts to reduce service costs. Gardner Denver also offers an after-sales service and spare parts.
Thermal dispersion switch for flow, level, interface, or temperatureFlow-Tech, Inc.
FCI liquid level/interface switches feature thermal dispersion technology in which the temperature difference between the two RTDs is greatest in the absence of liquid and decreases when the level element is submerged, cooling the heated RTD.
FCI flow switches feature thermal dispersion technology in which the temperature difference is greatest in a no-flow condition and decreases as flow increases, cooling the heated RTD. Changes in flow velocity directly affect the extent to which heat dissipates and, in turn, the magnitude of the temperature difference between the RTDs.
Turbine flow meters for gas service from HofferFlow-Tech, Inc.
Hoffer Flow Controls manufactures high precision turbine flowmeters for the cryogenic industry and is the world leader in turbine flowmeter technology for the measurement of clean liquids and gases throughout the processing industries.
The SITRANS P Z pressure transmitters measure gauge and absolute pressure as well as liquid and gas levels. They have a stainless steel housing and ceramic measuring cell that is temperature compensated. They are designed for use in various industries and can measure pressure of liquids, gases, and vapors in ranges from 0-400 bar or 0-6000 psi. They produce a 4-20 mA or 0-10 V DC output signal proportional to the measured pressure.
The SITRANS P250 transmitter measures the differential pressure of liquids and gases using a piezo-resistive measuring cell. It has a sturdy stainless steel enclosure and provides high measuring accuracy for use in various industries. The transmitter outputs a 4-20 mA or 0-5/10 VDC signal linearly proportional to the measured differential pressure. It is suitable for static and dynamic pressure measurements of gases and liquids.
1) Bossmanfilter BWC-Series water cooled aftercoolers use cooling water to lower the temperature of hot compressed air from an air compressor, allowing up to 63% of water in the air to be removed.
2) In a counter-flow heat exchanger, fluids flow in opposite directions to maximize heat transfer from the air to the cooling water.
3) The aftercoolers have applications in a wide range of industries, including manufacturing, food/beverage processing, and more.
In industrial practice, the precision of the measurement technology used is of increasing significance. This is especially the case where the accuracy of the measuring instruments is tested: in calibration. However, not all pressure or differential pressure calibrations can be carried out in a laboratory – the deinstallation of the test object is often not possible, for instance.
The Pneumator fulfils both requirements: it can be used not only for stationary applications (in a laboratory), but also as a mobile calibrator. In addition to this, it also serves as a precision
measuring instrument on site, combining highest accuracy with reliable battery operation.
The document describes the T600xxx-3 Series thermostats, which provide temperature control for heating and cooling equipment. The thermostats come in both non-programmable and programmable models for single-stage, heat pump, multi-stage, and economizer applications. Key features include an LCD display, simplified setpoint adjustment, configurable parameters, and compatibility with remote sensors. The thermostats use a proportional control algorithm to regulate temperature and include specifications for power, inputs, outputs, temperature range, accuracy, and dimensions.
The document summarizes information about Gardner Denver screw compressors ranging from 22-90 kW. It provides details on the ENDURO air ends, control unit, easy installation, low maintenance costs, base components, and the product range. Maintenance is designed to be easy via removable panels and a limited number of moving parts to reduce service costs. Gardner Denver also offers an after-sales service and spare parts.
Thermal dispersion switch for flow, level, interface, or temperatureFlow-Tech, Inc.
FCI liquid level/interface switches feature thermal dispersion technology in which the temperature difference between the two RTDs is greatest in the absence of liquid and decreases when the level element is submerged, cooling the heated RTD.
FCI flow switches feature thermal dispersion technology in which the temperature difference is greatest in a no-flow condition and decreases as flow increases, cooling the heated RTD. Changes in flow velocity directly affect the extent to which heat dissipates and, in turn, the magnitude of the temperature difference between the RTDs.
Turbine flow meters for gas service from HofferFlow-Tech, Inc.
Hoffer Flow Controls manufactures high precision turbine flowmeters for the cryogenic industry and is the world leader in turbine flowmeter technology for the measurement of clean liquids and gases throughout the processing industries.
Testo - 6448 - Compressed air counter shaft probeTesto Limited
The document summarizes a compressed air counter shaft probe that measures flow velocity, consumption, and temperature of compressed air. It can be installed under pressure on pipe diameters from DN40 to DN250. It has configurable outputs, a display, and totalizer. Its patented recoil protection allows safe installation without releasing pressure. It accurately positions in the pipe using an optional drilling clamp.
1. Bossmanfilter BAC-Series air cooled after coolers use ambient air to cool hot compressed air from air compressors, reducing the temperature by 5-20°F.
2. They remove up to 68% of water in compressed air and reduce the size and maintenance of downstream dryers.
3. Air cooled aftercoolers have applications in industries like manufacturing, food processing, and more where instrument air needs to be cooled.
GridPoint\’s Energy Management System Intelligent ControllersMichele_Zambrano333
GridPoint offers a new breed of intelligent Energy Management System (EMS)controllers equipped with revenue-grade accurate metering devices to monitor electricity, natural gas, propane, or water consumption. Our patented system transcends traditional energy management systems while having the ability to submeter, interface with alarm security systems, provides information to assist in monitoring facility maintenance services, and much more. The EMS delivers rapid ROI for buildings of 1,500 square feet and above.
Cảm biến áp suất SITRANS P hoạt động hữu hiệu với dải từ 1 mbar đến 400 bar (0.0145 psi đến 5800 psi) trong môi trường khắc nghiệt với ảnh hưởng bởi hoá chất, cơ khí và nhiễu từ trường. Ngoài ra các cảm biến này còn cung cấp tính năng tự giám sát, chuẩn đoán lỗi, thông báo trạng thái, đặc biệt là khả năng tự kiểm tra cho việc vận hành an toàn. Cảm biến có thể thay thế phần tử đo lường thuận tiện, dễ dàng, điều này giúp cho người dùng thuận lợi tiết kiệm chi phí sửa chữa đơn giản, nhanh, và giá thành hạ. Bộ chuyển đổi cảm biến áp suất SITRANS P có thể hoạt động tại chỗ hay điều khiển từ xa hoàn toàn Digital với giao thức PROFIBUS-PA hay HART.
http://cambiendoluong.vn/cam-bien-ap-suat/
This document summarizes calibration equipment from Sylvac and Trimos. The Sylvac Dial Gauge Calibrator precisely calibrates dial gauges and indicators using a digital readout. The Trimos THV Mini Horizontal Calibration Machine can perform a wide range of internal and external calibration tests using interchangeable probes and accessories to calibrate various measuring instruments. The Trimos Horizon 'H' Series Length Measuring Machine provides portable calibration for workshop use with a rechargeable battery and clearly defined digital display.
The 710 MINISIT is a multifunctional gas control device that can be used with stoves, boilers, and other appliances. It incorporates a thermoelectric flame supervision device, pressure regulator or flow adjuster, and modulating thermostat. The device comes in versions with either a pressure regulator to control outlet pressure, or a flow adjuster to control gas flow. It has components for ignition, flame sensing, gas flow control and temperature regulation.
Gönkā provided HVAC products and installations for several projects in Kazakhstan between 2002 and 2006, including government buildings, hotels, and factories. The document details Gönkā's work on projects like the High Court of Presidency Building in Astana, the CCC Business Center in Astana, the President Hotel in Astana, and the Kazakhstan Hay University. It provides pictures and specifications for some of the air handling units, chillers, fans, and other equipment installed at these locations.
SITRANS P MPS pressure transmitters are submersible sensors for hydrostatic level measurements. They contain a piezo-resistive sensor exposed to hydrostatic pressure, which is converted to a 4-20 mA output signal. They have compact IP68-rated housings and options for explosion protection. Junction boxes and cable hangers are available for simple installation.
The document discusses various process measurement techniques including pressure, temperature, tank gauging, and flow metering. It provides definitions and explanations of common measurement elements and indicators used for pressure like bourdon tubes, diaphragm gauges, and transmitters. It also covers temperature measurement using thermocouples, RTDs and their applications. Tank gauging methods like ATG and radar tank gauging are described. Finally, it discusses flow measurement using turbine meters and positive displacement meters.
This document discusses types of pressure gauges according to usage, including commercial and industrial gauges, process gauges, low pressure gauges, seal gauges, high precision test gauges, and duplex gauges. It also covers specifications, causes of acoustic-induced vibration, temperature limits, materials of construction, installation procedures, calibration methods using a dead weight tester, selection criteria, and conformity to industry standards.
High pressure transducers are engineers tools for utilitarian purposes and making things more Utopian in this impatient and fast developing world. Transducers provide proper mechanical equipment for completing a work. Here I provide a little information on this topic.
Fluid Controls is system certified with ISO 9001:2015, ISO 14001:2015 & ISO 18001:2018 and PED. We have design approvals for our product range from ABS and TUV and a wide range of product performance certifications and approvals.
The Claw-RTM system allows for real-time monitoring of reservoir pressure and temperature during well testing and production using the Jet Claw pump. It obtains reliable pressure and temperature data to optimize data collection time and well operations. Key components include high precision quartz sensors, tubing encapsulated cables, the smart Jet Claw pump with shut-off valve, connection tools, and a data logger. This provides advantages like optimizing well testing time and resources through real-time verification of pressure build-up tests.
This document discusses different types of sensors used to measure mechanical forces including strain gauges, hydraulic load cells, and pneumatic load cells. It begins by explaining electrical resistance and how strain gauges use changes in electrical resistance to measure strain. It describes various types of strain gauges including wire, foil, and semiconductor gauges. It then explains how hydraulic and pneumatic load cells use changes in liquid or air pressure to measure applied forces, with hydraulic cells being more accurate but smaller capacity than pneumatic cells.
The document provides information about the Motorola MPX4100 series Manifold Absolute Pressure (MAP) sensor.
The MPX4100 sensor is designed to sense absolute air pressure within an intake manifold to compute the amount of fuel required for each cylinder. It features temperature compensation, durable construction, and integrated signal conditioning. The document includes specifications, application examples, diagrams of the internal circuitry and packaging, and ordering information.
This document provides information on various types of electronic instruments. It describes the operating principles, construction, working and applications of PMMC meters, moving iron meters, rectifier type instruments, electrodynamometers, standard signal generators, ramp type digital voltmeters, and cathode ray oscilloscopes. Some key points covered include how PMMC meters and moving iron meters function using magnetic fields, the use of rectifiers to measure AC signals, and how ramp type DVMs and CROs analyze voltage signals over time.
The document discusses various types of pressure measurement instruments and concepts. It describes pressure gauges, transmitters, and transducers, explaining their measuring principles, components, installation considerations, and common terms. Diagrams illustrate typical configurations and components of differential pressure transmitters and loops.
Innovation case study submitted by Emirates Aluminium during 3rd Continual Improvement & Innovation Symposium organized by Dubai Quality Group's Continual Improvement Subgroup to celebrate World Quality Day 2011.
The document discusses various types of transducers including mechanical transducers, electrical transducers, LVDT, potentiometer, strain gauge, and resistance thermometer. It provides information on their working principles, construction details, applications, advantages, and limitations. The key points covered are that transducers convert one form of energy to another, electrical transducers are widely used for measurement as they allow remote sensing, and the selection of a transducer depends on factors like required accuracy, environmental conditions, errors, range, and resolution needed.
1) The document discusses field transmitters, providing information on their introduction, classification, operation, installation guidelines, and specifications.
2) Transmitters are used to transmit sensor signals over long distances in a standardized format and include features like HART communication.
3) The document covers transmitter components, calibration procedures, and specifications for factors like range, output, power supply, and temperature limits.
Testo - 6448 - Compressed air counter shaft probeTesto Limited
The document summarizes a compressed air counter shaft probe that measures flow velocity, consumption, and temperature of compressed air. It can be installed under pressure on pipe diameters from DN40 to DN250. It has configurable outputs, a display, and totalizer. Its patented recoil protection allows safe installation without releasing pressure. It accurately positions in the pipe using an optional drilling clamp.
1. Bossmanfilter BAC-Series air cooled after coolers use ambient air to cool hot compressed air from air compressors, reducing the temperature by 5-20°F.
2. They remove up to 68% of water in compressed air and reduce the size and maintenance of downstream dryers.
3. Air cooled aftercoolers have applications in industries like manufacturing, food processing, and more where instrument air needs to be cooled.
GridPoint\’s Energy Management System Intelligent ControllersMichele_Zambrano333
GridPoint offers a new breed of intelligent Energy Management System (EMS)controllers equipped with revenue-grade accurate metering devices to monitor electricity, natural gas, propane, or water consumption. Our patented system transcends traditional energy management systems while having the ability to submeter, interface with alarm security systems, provides information to assist in monitoring facility maintenance services, and much more. The EMS delivers rapid ROI for buildings of 1,500 square feet and above.
Cảm biến áp suất SITRANS P hoạt động hữu hiệu với dải từ 1 mbar đến 400 bar (0.0145 psi đến 5800 psi) trong môi trường khắc nghiệt với ảnh hưởng bởi hoá chất, cơ khí và nhiễu từ trường. Ngoài ra các cảm biến này còn cung cấp tính năng tự giám sát, chuẩn đoán lỗi, thông báo trạng thái, đặc biệt là khả năng tự kiểm tra cho việc vận hành an toàn. Cảm biến có thể thay thế phần tử đo lường thuận tiện, dễ dàng, điều này giúp cho người dùng thuận lợi tiết kiệm chi phí sửa chữa đơn giản, nhanh, và giá thành hạ. Bộ chuyển đổi cảm biến áp suất SITRANS P có thể hoạt động tại chỗ hay điều khiển từ xa hoàn toàn Digital với giao thức PROFIBUS-PA hay HART.
http://cambiendoluong.vn/cam-bien-ap-suat/
This document summarizes calibration equipment from Sylvac and Trimos. The Sylvac Dial Gauge Calibrator precisely calibrates dial gauges and indicators using a digital readout. The Trimos THV Mini Horizontal Calibration Machine can perform a wide range of internal and external calibration tests using interchangeable probes and accessories to calibrate various measuring instruments. The Trimos Horizon 'H' Series Length Measuring Machine provides portable calibration for workshop use with a rechargeable battery and clearly defined digital display.
The 710 MINISIT is a multifunctional gas control device that can be used with stoves, boilers, and other appliances. It incorporates a thermoelectric flame supervision device, pressure regulator or flow adjuster, and modulating thermostat. The device comes in versions with either a pressure regulator to control outlet pressure, or a flow adjuster to control gas flow. It has components for ignition, flame sensing, gas flow control and temperature regulation.
Gönkā provided HVAC products and installations for several projects in Kazakhstan between 2002 and 2006, including government buildings, hotels, and factories. The document details Gönkā's work on projects like the High Court of Presidency Building in Astana, the CCC Business Center in Astana, the President Hotel in Astana, and the Kazakhstan Hay University. It provides pictures and specifications for some of the air handling units, chillers, fans, and other equipment installed at these locations.
SITRANS P MPS pressure transmitters are submersible sensors for hydrostatic level measurements. They contain a piezo-resistive sensor exposed to hydrostatic pressure, which is converted to a 4-20 mA output signal. They have compact IP68-rated housings and options for explosion protection. Junction boxes and cable hangers are available for simple installation.
The document discusses various process measurement techniques including pressure, temperature, tank gauging, and flow metering. It provides definitions and explanations of common measurement elements and indicators used for pressure like bourdon tubes, diaphragm gauges, and transmitters. It also covers temperature measurement using thermocouples, RTDs and their applications. Tank gauging methods like ATG and radar tank gauging are described. Finally, it discusses flow measurement using turbine meters and positive displacement meters.
This document discusses types of pressure gauges according to usage, including commercial and industrial gauges, process gauges, low pressure gauges, seal gauges, high precision test gauges, and duplex gauges. It also covers specifications, causes of acoustic-induced vibration, temperature limits, materials of construction, installation procedures, calibration methods using a dead weight tester, selection criteria, and conformity to industry standards.
High pressure transducers are engineers tools for utilitarian purposes and making things more Utopian in this impatient and fast developing world. Transducers provide proper mechanical equipment for completing a work. Here I provide a little information on this topic.
Fluid Controls is system certified with ISO 9001:2015, ISO 14001:2015 & ISO 18001:2018 and PED. We have design approvals for our product range from ABS and TUV and a wide range of product performance certifications and approvals.
The Claw-RTM system allows for real-time monitoring of reservoir pressure and temperature during well testing and production using the Jet Claw pump. It obtains reliable pressure and temperature data to optimize data collection time and well operations. Key components include high precision quartz sensors, tubing encapsulated cables, the smart Jet Claw pump with shut-off valve, connection tools, and a data logger. This provides advantages like optimizing well testing time and resources through real-time verification of pressure build-up tests.
This document discusses different types of sensors used to measure mechanical forces including strain gauges, hydraulic load cells, and pneumatic load cells. It begins by explaining electrical resistance and how strain gauges use changes in electrical resistance to measure strain. It describes various types of strain gauges including wire, foil, and semiconductor gauges. It then explains how hydraulic and pneumatic load cells use changes in liquid or air pressure to measure applied forces, with hydraulic cells being more accurate but smaller capacity than pneumatic cells.
The document provides information about the Motorola MPX4100 series Manifold Absolute Pressure (MAP) sensor.
The MPX4100 sensor is designed to sense absolute air pressure within an intake manifold to compute the amount of fuel required for each cylinder. It features temperature compensation, durable construction, and integrated signal conditioning. The document includes specifications, application examples, diagrams of the internal circuitry and packaging, and ordering information.
This document provides information on various types of electronic instruments. It describes the operating principles, construction, working and applications of PMMC meters, moving iron meters, rectifier type instruments, electrodynamometers, standard signal generators, ramp type digital voltmeters, and cathode ray oscilloscopes. Some key points covered include how PMMC meters and moving iron meters function using magnetic fields, the use of rectifiers to measure AC signals, and how ramp type DVMs and CROs analyze voltage signals over time.
The document discusses various types of pressure measurement instruments and concepts. It describes pressure gauges, transmitters, and transducers, explaining their measuring principles, components, installation considerations, and common terms. Diagrams illustrate typical configurations and components of differential pressure transmitters and loops.
Innovation case study submitted by Emirates Aluminium during 3rd Continual Improvement & Innovation Symposium organized by Dubai Quality Group's Continual Improvement Subgroup to celebrate World Quality Day 2011.
The document discusses various types of transducers including mechanical transducers, electrical transducers, LVDT, potentiometer, strain gauge, and resistance thermometer. It provides information on their working principles, construction details, applications, advantages, and limitations. The key points covered are that transducers convert one form of energy to another, electrical transducers are widely used for measurement as they allow remote sensing, and the selection of a transducer depends on factors like required accuracy, environmental conditions, errors, range, and resolution needed.
1) The document discusses field transmitters, providing information on their introduction, classification, operation, installation guidelines, and specifications.
2) Transmitters are used to transmit sensor signals over long distances in a standardized format and include features like HART communication.
3) The document covers transmitter components, calibration procedures, and specifications for factors like range, output, power supply, and temperature limits.
ADDMAS Measurement able to manufacture & supply Pressure Gauges, Temperature Gauges, Process Control Equipment, Field Instruments. Excellent performance, robust construction & corrosion resistance is hallmark of our brand.
The document discusses various pressure measurement instruments such as pressure gauges, pressure switches, differential pressure gauges, and pressure transmitters. It describes the measuring principles, components, installation guidelines, and factors to consider when selecting pressure instruments for applications involving gases, liquids, and other process media. Proper instrument selection and installation is important to ensure accurate pressure measurement over the operating temperature and pressure ranges.
This document discusses various tuning tools, trimmer capacitors, and circuit elements from Jyoti Electronics. It describes glass and quartz piston capacitors approved to military specifications. It also mentions insulated tuning tools, sapphire trimmer capacitors, mica trimmer capacitors, multi-turn and single-turn air trimmer capacitors, microwave tuning elements, LC tuners and inductors, ceramic dielectric trimmer capacitors, SURFCOIL inductors and transformers, and FILMTRIM dielectric capacitors. The document also discusses varactor diode applications.
The document summarizes the MCIM micro single channel input unit, which is used to support Menvier fire control panels. The MCIM provides a single input that can monitor contacts like sprinkler switches. It is compact, soft addressed, and has built-in short circuit isolation. Variants include the MCIM-NF for non-fire uses and MCIM-C, which is identified as a callpoint.
Strain gauges are resistance elements that change resistance when subjected to strain. They consist of a grid wire or foil cemented between thin paper and bonded to a specimen. Strain gauges can be used to measure stress, force, torque, bending moment, and deflection proportionally to strain within the elastic limit. They are classified as metallic or nonmetallic and metallic gauges can be wire or foil types. Strain gauges are often mounted on elastic members called strain gauge transducers to provide a larger output that can be recorded or indicated remotely.
The document provides instructions for configuring an S7 connection between an S7-300 and an S7-400 for data exchange. It describes assigning IP addresses to the CP modules, entering the addresses in the hardware configurations, and configuring the connection bilaterally in the S7-300 and S7-400. Function blocks for sending and receiving data via specified and unspecified S7 connections are mentioned. The configuration includes settings like IP addresses, MAC addresses, and connection parameters.
EYETECK phân phối PLC siemens, PLCS71200, PLC S7-1200, tài liệu PLC S7-1200, giáo trình PLC S7-1200, phần mềm PLC S7-1200, lập trình PLC S7-1200, học PLC S7-1200.
http://eyeteck.vn
http://plcsiemens.vn
EYETECK phân phối PLC siemens, PLCS71200, PLC S7-1200, tài liệu PLC S7-1200, giáo trình PLC S7-1200, phần mềm PLC S7-1200, lập trình PLC S7-1200, học PLC S7-1200.
http://eyeteck.vn
http://plcsiemens.vn
The document discusses various SIMATIC S7-300 central processing units (CPUs) from Siemens including the CPU 312, CPU 314, CPU 315-2 DP, CPU 315-2 PN/DP, and CPU 317-2 PN/DP. It provides an overview of each CPU's features and specifications. It also lists brochures for SIMATIC product selection guides that can be found on Siemens' website.