SlideShare a Scribd company logo
1 of 24
Download to read offline
Bi-Articular Muscle Actuation Design 
for Robot Arms 
V. Salvucci Y. Kimura S. Oh Y. Hori 
Hori-Fujimoto Lab, The University of Tokyo 
ICRA 2011 Workshop on Biologically-inspired Actuation, Shanghai
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
Outline 
1 Bi-articularly Actuated Robot Arms 
2 Actuator Redundancy Problem 
Traditional: Pseudo-inverse Matrix (2  norm) 
Our Solution: The 1 norm Approach 
3 Experimental Setup 
BiWi:Bi-Articularly Actuated  Wire Driven Robot Arm 
Feedforward Control Strategy 
4 Experimental Results 
5 Conclusions 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 2/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
Outline 
1 Bi-articularly Actuated Robot Arms 
2 Actuator Redundancy Problem 
Traditional: Pseudo-inverse Matrix (2  norm) 
Our Solution: The 1 norm Approach 
3 Experimental Setup 
BiWi:Bi-Articularly Actuated  Wire Driven Robot Arm 
Feedforward Control Strategy 
4 Experimental Results 
5 Conclusions 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 3/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
What are Bi-articular Actuators? 
Multi-articular actuators produce torque in 2 (or more) consecutive joints 
Biceps brachii 
Coracobrachialis Brachialis 
Simpli
ed model of human musculo-skeletal structure 
f1 e1: antagonistic pair of mono-articular muscles 
f2 e2: antagonistic pair of mono-articular muscles 
f3  e3: antagonistic pair of bi-articular muscles 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 4/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
Why Bi-Articular Actuators? 
1 Homogeneous Maximum Force at End Eector [Fujikawa 1999] 
2 Impedance control without FB [Hogan 1985] 
3 Power transfer from proximal to distal joints [Schenau 1989] 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 5/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
Why Bi-Articular Actuators? 
2 actuators 
of 10 Nm 
each 
3 actuators 
of 6.6 Nm 
each 
Safety: smaller peak force (in case of controller failure) 
Vertical balance: greater ground horizontal force [Salvucci 2011b] 
1 Homogeneous Maximum Force at End Eector [Fujikawa 1999] 
2 Impedance control without FB [Hogan 1985] 
3 Power transfer from proximal to distal joints [Schenau 1989] 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 6/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
Why Bi-Articular Actuators? 
2 actuators 
of 10 Nm 
each 
3 actuators 
of 6.6 Nm 
each 
Safety: smaller peak force (in case of controller failure) 
Vertical balance: greater ground horizontal force [Salvucci 2011b] 
1 Homogeneous Maximum Force at End Eector [Fujikawa 1999] 
2 Impedance control without FB [Hogan 1985] 
3 Power transfer from proximal to distal joints [Schenau 1989] 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 7/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
Outline 
1 Bi-articularly Actuated Robot Arms 
2 Actuator Redundancy Problem 
Traditional: Pseudo-inverse Matrix (2  norm) 
Our Solution: The 1 norm Approach 
3 Experimental Setup 
BiWi:Bi-Articularly Actuated  Wire Driven Robot Arm 
Feedforward Control Strategy 
4 Experimental Results 
5 Conclusions 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 8/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
Actuator Redundancy Problem 
Model 
( 
T1 = (f1  e1)r + (f3  e3)r 
T2 = (f2  e2)r + (f3  e3)r 
Statics 
( 
T1 = 1 + 3 
T2 = 2 + 3 
Given desired T1 and T2 ) 1=?, 2=?, 3=? 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 9/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
Pseudo-inverse Matrix (2  norm) 
Moore Penrose is the simplest pseudo inverse matrix = 2  norm [Klein 1983] 
2  norm optimization criteria 
minimize 
q 
 2 
1 +  2 
2 +  2 
3 (1) 
subject to 
( 
T1 = 1 + 3 
T2 = 2 + 3 
(2) 
Closed form solution 
8 
: 
3T1  1 
3T2 
1 = 2 
2 = 1 
3T1 + 2 
3T2 
3T1 + 1 
3T2 
3 = 1 
(3) 
T = [2:0; 1:5] )  = [1:66; 0:33; 0:83] 
Given F ) T = 
 
JT  
F 
T )  using (3) 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 10/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
Our Solution: The 1 norm Approach [Salvucci 2010] 
1 norm optimization criteria 
minimize maxfj1j; j2j; j3jg (4) 
subject to 
( 
T1 = 1 + 3 
T2 = 2 + 3 
(5) 
Closed form solution [Salvucci 2010] 
if T1T2  0 ) 
8 
: 
1 = T1T2 
2 
2 = T2T1 
2 
3 = T1+T2 
2 
(6) 
if T1T2  0 
and jT1j  jT2j 
) 
8 
: 
1 = T1  T2 
2 
2 = T2 
2 
3 = T2 
2 
(7) 
if T1T2  0 
and jT1j  jT2j 
) 
8 
: 
1 = T1 
2 
2 = T2  T1 
2 
3 = T1 
2 
(8) 
T = [2:0; 1:5] )  = [1:0; 0:5; 1:0] 
Given F ) T = 
 
JT  
F 
T )  using (6), (7), or (8) 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 11/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
Outline 
1 Bi-articularly Actuated Robot Arms 
2 Actuator Redundancy Problem 
Traditional: Pseudo-inverse Matrix (2  norm) 
Our Solution: The 1 norm Approach 
3 Experimental Setup 
BiWi:Bi-Articularly Actuated  Wire Driven Robot Arm 
Feedforward Control Strategy 
4 Experimental Results 
5 Conclusions 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 12/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
BiWi: Bi-Articularly Actuated  Wire Driven Robot Arm [Salvucci 2011a] 
+ Human-like actuation structure 
+ Wire Transmission ) low link 
inertia (safety, energy eciency) 
+ Mono-/bi- articular torque 
decoupling (statics) 
- Not intrinsically compliant, but 
solvable with springs 
- Transmission loss in the wires 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 13/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
Feedforward Control Strategy 
x ; F 
y ]T and T = [T 
F = [F 
2 ]T : desired output forces and input 
1 ;T 
torque. 
[  
1 ,  
2 ,   
3 ]: desired actuator joint torques 
[e 
1 , f  
1 , e 
2 , f  
2 , e 
3 , f  
3 ]: motor reference torques calculated as: 
e 
i = 
 
Ktli   
i if   
i  0 
0 otherwise 
f  
i = 
 
Ki   
i if   
i  0 
0 otherwise 
(9) 
where Ktl2=1.33 (thrust wire transmission lost), Ktl1 = K3 = 0. 
Fx and Fy : measured forces at the end eector. 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 14/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
Outline 
1 Bi-articularly Actuated Robot Arms 
2 Actuator Redundancy Problem 
Traditional: Pseudo-inverse Matrix (2  norm) 
Our Solution: The 1 norm Approach 
3 Experimental Setup 
BiWi:Bi-Articularly Actuated  Wire Driven Robot Arm 
Feedforward Control Strategy 
4 Experimental Results 
5 Conclusions 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 15/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
In
nity Norm VS Pseudo-inverse matrix (2  norm) [Salvucci 2011c] 
1 = 60 
2 = 120 
1 = 25 
2 = 50 
Measured maximum output force Relative dierence in output force 
Fdi = 
jF1nj  jF2nj 
jF2nj 
(10) 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 16/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
Outline 
1 Bi-articularly Actuated Robot Arms 
2 Actuator Redundancy Problem 
Traditional: Pseudo-inverse Matrix (2  norm) 
Our Solution: The 1 norm Approach 
3 Experimental Setup 
BiWi:Bi-Articularly Actuated  Wire Driven Robot Arm 
Feedforward Control Strategy 
4 Experimental Results 
5 Conclusions 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 17/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
Conclusions 
Bi-articular muscles key points 
1 Homogeneous distribution of output force 
2 Power transfer proximal to distal joints 
3 FF impedance control 
BiWi, Bi-articularly actuated and Wire driven Robot Arm 
Human-like actuation structure 
Low link-inertia ) Safety, eciency 
Perfect decoupling between mono- and bi- articular actuator (statics) 
The 1 norm approach for actuator redundancy resolution 
Closed form solution based on a piecewise linear function continuous in 
all the domain D = fT1;T2g 
Maximization of force at the end eector: +30% than 2  norm 
Applicable to systems with 3 inputs and 2 outputs 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 18/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
Conclusions 
Bi-articular muscles key points 
1 Homogeneous distribution of output force 
2 Power transfer proximal to distal joints 
3 FF impedance control 
BiWi, Bi-articularly actuated and Wire driven Robot Arm 
Human-like actuation structure 
Low link-inertia ) Safety, eciency 
Perfect decoupling between mono- and bi- articular actuator (statics) 
The 1 norm approach for actuator redundancy resolution 
Closed form solution based on a piecewise linear function continuous in 
all the domain D = fT1;T2g 
Maximization of force at the end eector: +30% than 2  norm 
Applicable to systems with 3 inputs and 2 outputs 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 19/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
Conclusions 
Bi-articular muscles key points 
1 Homogeneous distribution of output force 
2 Power transfer proximal to distal joints 
3 FF impedance control 
BiWi, Bi-articularly actuated and Wire driven Robot Arm 
Human-like actuation structure 
Low link-inertia ) Safety, eciency 
Perfect decoupling between mono- and bi- articular actuator (statics) 
The 1 norm approach for actuator redundancy resolution 
Closed form solution based on a piecewise linear function continuous in 
all the domain D = fT1;T2g 
Maximization of force at the end eector: +30% than 2  norm 
Applicable to systems with 3 inputs and 2 outputs 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 20/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
Thank you for your kind attention 
V. Salvucci Y. Kimura S. Oh Y. Hori 
www.hori.k.u-tokyo.ac.jp www.valeriosalvucci.com 
V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo 
Bi-Articular Muscle Actuation Design for Robot Arms 21/24
Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 
2  norm Vs 1 norm in 2D 
Equation with in

More Related Content

Similar to Bi-articular Muscle Actuation Design for Robot Arms

Adaptive Biarticular Muscle Force Control for Humanoid Robot Arms
Adaptive Biarticular Muscle Force Control for Humanoid Robot ArmsAdaptive Biarticular Muscle Force Control for Humanoid Robot Arms
Adaptive Biarticular Muscle Force Control for Humanoid Robot Armstoukaigi
 
Intelligent Control Systems for Humanoid Robot: Master Thesis_Owen Chih-Hsuan...
Intelligent Control Systems for Humanoid Robot: Master Thesis_Owen Chih-Hsuan...Intelligent Control Systems for Humanoid Robot: Master Thesis_Owen Chih-Hsuan...
Intelligent Control Systems for Humanoid Robot: Master Thesis_Owen Chih-Hsuan...Owen (Chih-Hsuan) Chen
 
Robust Control of Rotor/AMB Systems
Robust Control of Rotor/AMB SystemsRobust Control of Rotor/AMB Systems
Robust Control of Rotor/AMB SystemsSina Kuseyri
 
Predicting Guinea Fowl Muscle Forces During Perturbed Gaits (10:28th)
Predicting Guinea Fowl Muscle Forces During Perturbed Gaits (10:28th)Predicting Guinea Fowl Muscle Forces During Perturbed Gaits (10:28th)
Predicting Guinea Fowl Muscle Forces During Perturbed Gaits (10:28th)Christopher Whitney
 
Haifu ev iecon13tutorial
Haifu ev iecon13tutorialHaifu ev iecon13tutorial
Haifu ev iecon13tutorialsupra_uny
 
Robotics (2.008x Lecture Slides)
Robotics (2.008x Lecture Slides)Robotics (2.008x Lecture Slides)
Robotics (2.008x Lecture Slides)A. John Hart
 
The Analysis of Aluminium Cantilever Beam with Piezoelectric Material by Chan...
The Analysis of Aluminium Cantilever Beam with Piezoelectric Material by Chan...The Analysis of Aluminium Cantilever Beam with Piezoelectric Material by Chan...
The Analysis of Aluminium Cantilever Beam with Piezoelectric Material by Chan...IRJET Journal
 
Natural Vibration Analysis of Femur Bone Using Hyperworks
Natural Vibration Analysis of Femur Bone Using HyperworksNatural Vibration Analysis of Femur Bone Using Hyperworks
Natural Vibration Analysis of Femur Bone Using HyperworksIJERA Editor
 
Kinematic control with singularity avoidance for teaching-playback robot mani...
Kinematic control with singularity avoidance for teaching-playback robot mani...Kinematic control with singularity avoidance for teaching-playback robot mani...
Kinematic control with singularity avoidance for teaching-playback robot mani...Baron Y.S. Yong
 
Human gait simulation using python
Human gait simulation using pythonHuman gait simulation using python
Human gait simulation using pythonHarish Kant Soni
 
Design & Development of Articulated Inspection ARM for in House Inspection in...
Design & Development of Articulated Inspection ARM for in House Inspection in...Design & Development of Articulated Inspection ARM for in House Inspection in...
Design & Development of Articulated Inspection ARM for in House Inspection in...ijsrd.com
 
Robust Control of Rotor/AMB Systems
Robust Control of Rotor/AMB SystemsRobust Control of Rotor/AMB Systems
Robust Control of Rotor/AMB SystemsSina Kuseyri
 
A comparative study of controllers for stabilizing a rotary inverted pendulum
A comparative study of controllers for stabilizing a rotary inverted pendulumA comparative study of controllers for stabilizing a rotary inverted pendulum
A comparative study of controllers for stabilizing a rotary inverted pendulumijccmsjournal
 
A Comparative study of controllers for stabilizing a Rotary Inverted Pendulum
A Comparative study of controllers for stabilizing a Rotary Inverted PendulumA Comparative study of controllers for stabilizing a Rotary Inverted Pendulum
A Comparative study of controllers for stabilizing a Rotary Inverted Pendulumijccmsjournal
 

Similar to Bi-articular Muscle Actuation Design for Robot Arms (20)

Adaptive Biarticular Muscle Force Control for Humanoid Robot Arms
Adaptive Biarticular Muscle Force Control for Humanoid Robot ArmsAdaptive Biarticular Muscle Force Control for Humanoid Robot Arms
Adaptive Biarticular Muscle Force Control for Humanoid Robot Arms
 
Intelligent Control Systems for Humanoid Robot: Master Thesis_Owen Chih-Hsuan...
Intelligent Control Systems for Humanoid Robot: Master Thesis_Owen Chih-Hsuan...Intelligent Control Systems for Humanoid Robot: Master Thesis_Owen Chih-Hsuan...
Intelligent Control Systems for Humanoid Robot: Master Thesis_Owen Chih-Hsuan...
 
Robot Hexapod - Terfinal2.pptx
Robot Hexapod - Terfinal2.pptxRobot Hexapod - Terfinal2.pptx
Robot Hexapod - Terfinal2.pptx
 
Project Presentation Nus
Project Presentation NusProject Presentation Nus
Project Presentation Nus
 
Project Presentation Nus
Project Presentation NusProject Presentation Nus
Project Presentation Nus
 
Unit I_dany (1).pptx
Unit I_dany (1).pptxUnit I_dany (1).pptx
Unit I_dany (1).pptx
 
Robust Control of Rotor/AMB Systems
Robust Control of Rotor/AMB SystemsRobust Control of Rotor/AMB Systems
Robust Control of Rotor/AMB Systems
 
Predicting Guinea Fowl Muscle Forces During Perturbed Gaits (10:28th)
Predicting Guinea Fowl Muscle Forces During Perturbed Gaits (10:28th)Predicting Guinea Fowl Muscle Forces During Perturbed Gaits (10:28th)
Predicting Guinea Fowl Muscle Forces During Perturbed Gaits (10:28th)
 
Haifu ev iecon13tutorial
Haifu ev iecon13tutorialHaifu ev iecon13tutorial
Haifu ev iecon13tutorial
 
Robotics (2.008x Lecture Slides)
Robotics (2.008x Lecture Slides)Robotics (2.008x Lecture Slides)
Robotics (2.008x Lecture Slides)
 
The Analysis of Aluminium Cantilever Beam with Piezoelectric Material by Chan...
The Analysis of Aluminium Cantilever Beam with Piezoelectric Material by Chan...The Analysis of Aluminium Cantilever Beam with Piezoelectric Material by Chan...
The Analysis of Aluminium Cantilever Beam with Piezoelectric Material by Chan...
 
Natural Vibration Analysis of Femur Bone Using Hyperworks
Natural Vibration Analysis of Femur Bone Using HyperworksNatural Vibration Analysis of Femur Bone Using Hyperworks
Natural Vibration Analysis of Femur Bone Using Hyperworks
 
Presentation2
Presentation2Presentation2
Presentation2
 
Kinematic control with singularity avoidance for teaching-playback robot mani...
Kinematic control with singularity avoidance for teaching-playback robot mani...Kinematic control with singularity avoidance for teaching-playback robot mani...
Kinematic control with singularity avoidance for teaching-playback robot mani...
 
Human gait simulation using python
Human gait simulation using pythonHuman gait simulation using python
Human gait simulation using python
 
Design & Development of Articulated Inspection ARM for in House Inspection in...
Design & Development of Articulated Inspection ARM for in House Inspection in...Design & Development of Articulated Inspection ARM for in House Inspection in...
Design & Development of Articulated Inspection ARM for in House Inspection in...
 
Robust Control of Rotor/AMB Systems
Robust Control of Rotor/AMB SystemsRobust Control of Rotor/AMB Systems
Robust Control of Rotor/AMB Systems
 
A comparative study of controllers for stabilizing a rotary inverted pendulum
A comparative study of controllers for stabilizing a rotary inverted pendulumA comparative study of controllers for stabilizing a rotary inverted pendulum
A comparative study of controllers for stabilizing a rotary inverted pendulum
 
A Comparative study of controllers for stabilizing a Rotary Inverted Pendulum
A Comparative study of controllers for stabilizing a Rotary Inverted PendulumA Comparative study of controllers for stabilizing a Rotary Inverted Pendulum
A Comparative study of controllers for stabilizing a Rotary Inverted Pendulum
 
HI-POCT Conference Paper
HI-POCT Conference PaperHI-POCT Conference Paper
HI-POCT Conference Paper
 

Recently uploaded

Unlocking the Potential: Deep dive into ocean of Ceramic Magnets.pptx
Unlocking  the Potential: Deep dive into ocean of Ceramic Magnets.pptxUnlocking  the Potential: Deep dive into ocean of Ceramic Magnets.pptx
Unlocking the Potential: Deep dive into ocean of Ceramic Magnets.pptxanandsmhk
 
Natural Polymer Based Nanomaterials
Natural Polymer Based NanomaterialsNatural Polymer Based Nanomaterials
Natural Polymer Based NanomaterialsAArockiyaNisha
 
Call Girls in Munirka Delhi 💯Call Us 🔝9953322196🔝 💯Escort.
Call Girls in Munirka Delhi 💯Call Us 🔝9953322196🔝 💯Escort.Call Girls in Munirka Delhi 💯Call Us 🔝9953322196🔝 💯Escort.
Call Girls in Munirka Delhi 💯Call Us 🔝9953322196🔝 💯Escort.aasikanpl
 
GFP in rDNA Technology (Biotechnology).pptx
GFP in rDNA Technology (Biotechnology).pptxGFP in rDNA Technology (Biotechnology).pptx
GFP in rDNA Technology (Biotechnology).pptxAleenaTreesaSaji
 
Isotopic evidence of long-lived volcanism on Io
Isotopic evidence of long-lived volcanism on IoIsotopic evidence of long-lived volcanism on Io
Isotopic evidence of long-lived volcanism on IoSérgio Sacani
 
zoogeography of pakistan.pptx fauna of Pakistan
zoogeography of pakistan.pptx fauna of Pakistanzoogeography of pakistan.pptx fauna of Pakistan
zoogeography of pakistan.pptx fauna of Pakistanzohaibmir069
 
Grafana in space: Monitoring Japan's SLIM moon lander in real time
Grafana in space: Monitoring Japan's SLIM moon lander  in real timeGrafana in space: Monitoring Japan's SLIM moon lander  in real time
Grafana in space: Monitoring Japan's SLIM moon lander in real timeSatoshi NAKAHIRA
 
Scheme-of-Work-Science-Stage-4 cambridge science.docx
Scheme-of-Work-Science-Stage-4 cambridge science.docxScheme-of-Work-Science-Stage-4 cambridge science.docx
Scheme-of-Work-Science-Stage-4 cambridge science.docxyaramohamed343013
 
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCRStunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCRDelhi Call girls
 
Labelling Requirements and Label Claims for Dietary Supplements and Recommend...
Labelling Requirements and Label Claims for Dietary Supplements and Recommend...Labelling Requirements and Label Claims for Dietary Supplements and Recommend...
Labelling Requirements and Label Claims for Dietary Supplements and Recommend...Lokesh Kothari
 
Analytical Profile of Coleus Forskohlii | Forskolin .pptx
Analytical Profile of Coleus Forskohlii | Forskolin .pptxAnalytical Profile of Coleus Forskohlii | Forskolin .pptx
Analytical Profile of Coleus Forskohlii | Forskolin .pptxSwapnil Therkar
 
Luciferase in rDNA technology (biotechnology).pptx
Luciferase in rDNA technology (biotechnology).pptxLuciferase in rDNA technology (biotechnology).pptx
Luciferase in rDNA technology (biotechnology).pptxAleenaTreesaSaji
 
Work, Energy and Power for class 10 ICSE Physics
Work, Energy and Power for class 10 ICSE PhysicsWork, Energy and Power for class 10 ICSE Physics
Work, Energy and Power for class 10 ICSE Physicsvishikhakeshava1
 
Boyles law module in the grade 10 science
Boyles law module in the grade 10 scienceBoyles law module in the grade 10 science
Boyles law module in the grade 10 sciencefloriejanemacaya1
 
G9 Science Q4- Week 1-2 Projectile Motion.ppt
G9 Science Q4- Week 1-2 Projectile Motion.pptG9 Science Q4- Week 1-2 Projectile Motion.ppt
G9 Science Q4- Week 1-2 Projectile Motion.pptMAESTRELLAMesa2
 
Artificial Intelligence In Microbiology by Dr. Prince C P
Artificial Intelligence In Microbiology by Dr. Prince C PArtificial Intelligence In Microbiology by Dr. Prince C P
Artificial Intelligence In Microbiology by Dr. Prince C PPRINCE C P
 
Recombination DNA Technology (Nucleic Acid Hybridization )
Recombination DNA Technology (Nucleic Acid Hybridization )Recombination DNA Technology (Nucleic Acid Hybridization )
Recombination DNA Technology (Nucleic Acid Hybridization )aarthirajkumar25
 
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...Sérgio Sacani
 

Recently uploaded (20)

Unlocking the Potential: Deep dive into ocean of Ceramic Magnets.pptx
Unlocking  the Potential: Deep dive into ocean of Ceramic Magnets.pptxUnlocking  the Potential: Deep dive into ocean of Ceramic Magnets.pptx
Unlocking the Potential: Deep dive into ocean of Ceramic Magnets.pptx
 
Natural Polymer Based Nanomaterials
Natural Polymer Based NanomaterialsNatural Polymer Based Nanomaterials
Natural Polymer Based Nanomaterials
 
Call Girls in Munirka Delhi 💯Call Us 🔝9953322196🔝 💯Escort.
Call Girls in Munirka Delhi 💯Call Us 🔝9953322196🔝 💯Escort.Call Girls in Munirka Delhi 💯Call Us 🔝9953322196🔝 💯Escort.
Call Girls in Munirka Delhi 💯Call Us 🔝9953322196🔝 💯Escort.
 
GFP in rDNA Technology (Biotechnology).pptx
GFP in rDNA Technology (Biotechnology).pptxGFP in rDNA Technology (Biotechnology).pptx
GFP in rDNA Technology (Biotechnology).pptx
 
Isotopic evidence of long-lived volcanism on Io
Isotopic evidence of long-lived volcanism on IoIsotopic evidence of long-lived volcanism on Io
Isotopic evidence of long-lived volcanism on Io
 
zoogeography of pakistan.pptx fauna of Pakistan
zoogeography of pakistan.pptx fauna of Pakistanzoogeography of pakistan.pptx fauna of Pakistan
zoogeography of pakistan.pptx fauna of Pakistan
 
Grafana in space: Monitoring Japan's SLIM moon lander in real time
Grafana in space: Monitoring Japan's SLIM moon lander  in real timeGrafana in space: Monitoring Japan's SLIM moon lander  in real time
Grafana in space: Monitoring Japan's SLIM moon lander in real time
 
Scheme-of-Work-Science-Stage-4 cambridge science.docx
Scheme-of-Work-Science-Stage-4 cambridge science.docxScheme-of-Work-Science-Stage-4 cambridge science.docx
Scheme-of-Work-Science-Stage-4 cambridge science.docx
 
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCRStunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
 
Labelling Requirements and Label Claims for Dietary Supplements and Recommend...
Labelling Requirements and Label Claims for Dietary Supplements and Recommend...Labelling Requirements and Label Claims for Dietary Supplements and Recommend...
Labelling Requirements and Label Claims for Dietary Supplements and Recommend...
 
Engler and Prantl system of classification in plant taxonomy
Engler and Prantl system of classification in plant taxonomyEngler and Prantl system of classification in plant taxonomy
Engler and Prantl system of classification in plant taxonomy
 
Analytical Profile of Coleus Forskohlii | Forskolin .pptx
Analytical Profile of Coleus Forskohlii | Forskolin .pptxAnalytical Profile of Coleus Forskohlii | Forskolin .pptx
Analytical Profile of Coleus Forskohlii | Forskolin .pptx
 
Luciferase in rDNA technology (biotechnology).pptx
Luciferase in rDNA technology (biotechnology).pptxLuciferase in rDNA technology (biotechnology).pptx
Luciferase in rDNA technology (biotechnology).pptx
 
Work, Energy and Power for class 10 ICSE Physics
Work, Energy and Power for class 10 ICSE PhysicsWork, Energy and Power for class 10 ICSE Physics
Work, Energy and Power for class 10 ICSE Physics
 
Boyles law module in the grade 10 science
Boyles law module in the grade 10 scienceBoyles law module in the grade 10 science
Boyles law module in the grade 10 science
 
G9 Science Q4- Week 1-2 Projectile Motion.ppt
G9 Science Q4- Week 1-2 Projectile Motion.pptG9 Science Q4- Week 1-2 Projectile Motion.ppt
G9 Science Q4- Week 1-2 Projectile Motion.ppt
 
Artificial Intelligence In Microbiology by Dr. Prince C P
Artificial Intelligence In Microbiology by Dr. Prince C PArtificial Intelligence In Microbiology by Dr. Prince C P
Artificial Intelligence In Microbiology by Dr. Prince C P
 
Recombination DNA Technology (Nucleic Acid Hybridization )
Recombination DNA Technology (Nucleic Acid Hybridization )Recombination DNA Technology (Nucleic Acid Hybridization )
Recombination DNA Technology (Nucleic Acid Hybridization )
 
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
 
The Philosophy of Science
The Philosophy of ScienceThe Philosophy of Science
The Philosophy of Science
 

Bi-articular Muscle Actuation Design for Robot Arms

  • 1. Bi-Articular Muscle Actuation Design for Robot Arms V. Salvucci Y. Kimura S. Oh Y. Hori Hori-Fujimoto Lab, The University of Tokyo ICRA 2011 Workshop on Biologically-inspired Actuation, Shanghai
  • 2. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References Outline 1 Bi-articularly Actuated Robot Arms 2 Actuator Redundancy Problem Traditional: Pseudo-inverse Matrix (2 norm) Our Solution: The 1 norm Approach 3 Experimental Setup BiWi:Bi-Articularly Actuated Wire Driven Robot Arm Feedforward Control Strategy 4 Experimental Results 5 Conclusions V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 2/24
  • 3. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References Outline 1 Bi-articularly Actuated Robot Arms 2 Actuator Redundancy Problem Traditional: Pseudo-inverse Matrix (2 norm) Our Solution: The 1 norm Approach 3 Experimental Setup BiWi:Bi-Articularly Actuated Wire Driven Robot Arm Feedforward Control Strategy 4 Experimental Results 5 Conclusions V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 3/24
  • 4. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References What are Bi-articular Actuators? Multi-articular actuators produce torque in 2 (or more) consecutive joints Biceps brachii Coracobrachialis Brachialis Simpli
  • 5. ed model of human musculo-skeletal structure f1 e1: antagonistic pair of mono-articular muscles f2 e2: antagonistic pair of mono-articular muscles f3 e3: antagonistic pair of bi-articular muscles V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 4/24
  • 6. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References Why Bi-Articular Actuators? 1 Homogeneous Maximum Force at End Eector [Fujikawa 1999] 2 Impedance control without FB [Hogan 1985] 3 Power transfer from proximal to distal joints [Schenau 1989] V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 5/24
  • 7. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References Why Bi-Articular Actuators? 2 actuators of 10 Nm each 3 actuators of 6.6 Nm each Safety: smaller peak force (in case of controller failure) Vertical balance: greater ground horizontal force [Salvucci 2011b] 1 Homogeneous Maximum Force at End Eector [Fujikawa 1999] 2 Impedance control without FB [Hogan 1985] 3 Power transfer from proximal to distal joints [Schenau 1989] V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 6/24
  • 8. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References Why Bi-Articular Actuators? 2 actuators of 10 Nm each 3 actuators of 6.6 Nm each Safety: smaller peak force (in case of controller failure) Vertical balance: greater ground horizontal force [Salvucci 2011b] 1 Homogeneous Maximum Force at End Eector [Fujikawa 1999] 2 Impedance control without FB [Hogan 1985] 3 Power transfer from proximal to distal joints [Schenau 1989] V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 7/24
  • 9. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References Outline 1 Bi-articularly Actuated Robot Arms 2 Actuator Redundancy Problem Traditional: Pseudo-inverse Matrix (2 norm) Our Solution: The 1 norm Approach 3 Experimental Setup BiWi:Bi-Articularly Actuated Wire Driven Robot Arm Feedforward Control Strategy 4 Experimental Results 5 Conclusions V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 8/24
  • 10. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References Actuator Redundancy Problem Model ( T1 = (f1 e1)r + (f3 e3)r T2 = (f2 e2)r + (f3 e3)r Statics ( T1 = 1 + 3 T2 = 2 + 3 Given desired T1 and T2 ) 1=?, 2=?, 3=? V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 9/24
  • 11. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References Pseudo-inverse Matrix (2 norm) Moore Penrose is the simplest pseudo inverse matrix = 2 norm [Klein 1983] 2 norm optimization criteria minimize q 2 1 + 2 2 + 2 3 (1) subject to ( T1 = 1 + 3 T2 = 2 + 3 (2) Closed form solution 8 : 3T1 1 3T2 1 = 2 2 = 1 3T1 + 2 3T2 3T1 + 1 3T2 3 = 1 (3) T = [2:0; 1:5] ) = [1:66; 0:33; 0:83] Given F ) T = JT F T ) using (3) V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 10/24
  • 12. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References Our Solution: The 1 norm Approach [Salvucci 2010] 1 norm optimization criteria minimize maxfj1j; j2j; j3jg (4) subject to ( T1 = 1 + 3 T2 = 2 + 3 (5) Closed form solution [Salvucci 2010] if T1T2 0 ) 8 : 1 = T1T2 2 2 = T2T1 2 3 = T1+T2 2 (6) if T1T2 0 and jT1j jT2j ) 8 : 1 = T1 T2 2 2 = T2 2 3 = T2 2 (7) if T1T2 0 and jT1j jT2j ) 8 : 1 = T1 2 2 = T2 T1 2 3 = T1 2 (8) T = [2:0; 1:5] ) = [1:0; 0:5; 1:0] Given F ) T = JT F T ) using (6), (7), or (8) V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 11/24
  • 13. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References Outline 1 Bi-articularly Actuated Robot Arms 2 Actuator Redundancy Problem Traditional: Pseudo-inverse Matrix (2 norm) Our Solution: The 1 norm Approach 3 Experimental Setup BiWi:Bi-Articularly Actuated Wire Driven Robot Arm Feedforward Control Strategy 4 Experimental Results 5 Conclusions V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 12/24
  • 14. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References BiWi: Bi-Articularly Actuated Wire Driven Robot Arm [Salvucci 2011a] + Human-like actuation structure + Wire Transmission ) low link inertia (safety, energy eciency) + Mono-/bi- articular torque decoupling (statics) - Not intrinsically compliant, but solvable with springs - Transmission loss in the wires V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 13/24
  • 15. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References Feedforward Control Strategy x ; F y ]T and T = [T F = [F 2 ]T : desired output forces and input 1 ;T torque. [ 1 , 2 , 3 ]: desired actuator joint torques [e 1 , f 1 , e 2 , f 2 , e 3 , f 3 ]: motor reference torques calculated as: e i = Ktli i if i 0 0 otherwise f i = Ki i if i 0 0 otherwise (9) where Ktl2=1.33 (thrust wire transmission lost), Ktl1 = K3 = 0. Fx and Fy : measured forces at the end eector. V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 14/24
  • 16. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References Outline 1 Bi-articularly Actuated Robot Arms 2 Actuator Redundancy Problem Traditional: Pseudo-inverse Matrix (2 norm) Our Solution: The 1 norm Approach 3 Experimental Setup BiWi:Bi-Articularly Actuated Wire Driven Robot Arm Feedforward Control Strategy 4 Experimental Results 5 Conclusions V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 15/24
  • 17. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References In
  • 18. nity Norm VS Pseudo-inverse matrix (2 norm) [Salvucci 2011c] 1 = 60 2 = 120 1 = 25 2 = 50 Measured maximum output force Relative dierence in output force Fdi = jF1nj jF2nj jF2nj (10) V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 16/24
  • 19. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References Outline 1 Bi-articularly Actuated Robot Arms 2 Actuator Redundancy Problem Traditional: Pseudo-inverse Matrix (2 norm) Our Solution: The 1 norm Approach 3 Experimental Setup BiWi:Bi-Articularly Actuated Wire Driven Robot Arm Feedforward Control Strategy 4 Experimental Results 5 Conclusions V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 17/24
  • 20. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References Conclusions Bi-articular muscles key points 1 Homogeneous distribution of output force 2 Power transfer proximal to distal joints 3 FF impedance control BiWi, Bi-articularly actuated and Wire driven Robot Arm Human-like actuation structure Low link-inertia ) Safety, eciency Perfect decoupling between mono- and bi- articular actuator (statics) The 1 norm approach for actuator redundancy resolution Closed form solution based on a piecewise linear function continuous in all the domain D = fT1;T2g Maximization of force at the end eector: +30% than 2 norm Applicable to systems with 3 inputs and 2 outputs V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 18/24
  • 21. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References Conclusions Bi-articular muscles key points 1 Homogeneous distribution of output force 2 Power transfer proximal to distal joints 3 FF impedance control BiWi, Bi-articularly actuated and Wire driven Robot Arm Human-like actuation structure Low link-inertia ) Safety, eciency Perfect decoupling between mono- and bi- articular actuator (statics) The 1 norm approach for actuator redundancy resolution Closed form solution based on a piecewise linear function continuous in all the domain D = fT1;T2g Maximization of force at the end eector: +30% than 2 norm Applicable to systems with 3 inputs and 2 outputs V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 19/24
  • 22. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References Conclusions Bi-articular muscles key points 1 Homogeneous distribution of output force 2 Power transfer proximal to distal joints 3 FF impedance control BiWi, Bi-articularly actuated and Wire driven Robot Arm Human-like actuation structure Low link-inertia ) Safety, eciency Perfect decoupling between mono- and bi- articular actuator (statics) The 1 norm approach for actuator redundancy resolution Closed form solution based on a piecewise linear function continuous in all the domain D = fT1;T2g Maximization of force at the end eector: +30% than 2 norm Applicable to systems with 3 inputs and 2 outputs V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 20/24
  • 23. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References Thank you for your kind attention V. Salvucci Y. Kimura S. Oh Y. Hori www.hori.k.u-tokyo.ac.jp www.valeriosalvucci.com V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 21/24
  • 24. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References 2 norm Vs 1 norm in 2D Equation with in
  • 26. y k, and
  • 27. are constant x and y represent the motor torques ) bounded 2 norm minimize p x2 + y2 1 norm minimize max fjxj; jyjg Comparison Solutions comparison maxfy1; x1g maxfy2; x2g Smaller solution space for 2 norm no solution for 2 norm!! V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 22/24
  • 28. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References The Best Norm Output Force for 2 2 f30; 60; 90; 120; 150g j1j + j2j + j3j for 2 = 90 norm 1 norm 2 norm 1 min (j1j + j2j + j3j) min ( p 2 1 + 2 2 + 2 3 ) min maxfj1j; j2j; j3jg j1j + j2j + j3j of 1 norm j1j + j2j + j3j of 2 norm j1j + j2j + j3j of 2 norm j1j + j2j + j3j of 1 norm The best norm: switching between 1 norm, 2 norm and 1 norm . . . but the system could not be stable due to discontinuity in torque patterns V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 23/24
  • 29. Bi-articularly Actuated Robot Arms Actuator Redundancy Problem Experimental Setup Experimental Results Conclusions References References T. Fujikawa, T. Oshima, M. Kumamoto, and N. Yokoi. Output force at the endpoint in human upper extremities and coordinating activities of each antagonistic pairs of muscles. Transactions of the Japan Society of Mechanical Engineers. C, 65(632): 1557{1564, 1999. N. Hogan. The mechanics of multi-joint posture and movement control. Biological Cybernetics, 52(5):315{331, 1985. V. Salvucci, S. Oh, and Y. Hori. In
  • 30. nity norm approach for precise force control of manipulators driven by bi-articular actuators. In IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society, pages 1908{1913, 2010. V. Salvucci, Y. Kimura, S. Oh, and Y. Hori. BiWi: Bi-Articularly actuated and wire driven robot arm. In IEEE International Conference on Mechatronics (ICM), 2011a. V. Salvucci, Y. Kimura, S. Oh, and Y. Hori. Disturbance rejection improvement in Non-Redundant robot arms by bi-articular actuators. In Industrial Electronics (ISIE), IEEE International Symposium on, 2011b. V. Salvucci, Y. Kimura, S. Oh, and Y. Hori. Experimental veri
  • 32. nity norm approach for force maximization of manipulators driven by bi-articular actuators. In American Control Conference (ACC), 2011c. G. J. V. I. Schenau. From rotation to translation: Constraints on multi-joint movements and the unique action of bi-articular muscles. Human Movement Science, 8(4):301{337, Aug. 1989. V. Salvucci, Y. Kimura, S. Oh, Y. Hori Hori-Fujimoto Lab, The University of Tokyo Bi-Articular Muscle Actuation Design for Robot Arms 24/24