97.52.06.0810 HP-N-Ex 03/091
AEROSTAT®
HP-N-Ex
Ionising Air Blower
User’s Manual UK
CONTENTS
Page
1. Introduction 2
2. Safety 2
3. Use and operation 2
4. Technical specifications 3
5. Installation 4
6. Putting into use 5
7. Functional check 5
8. Maintenance 6
9. Faults 6
10. Repair 7
11. Disposal 7
12. Spares 7
CE declaration 9
1180
BAS00ATEX2162X
II 2G Ex smb IIB T4 (Bar)
II 2G c T4 / T3 (Blower)
II 2G Ex e II T4 / T3 (Motor)
SIMCO (Nederland) B.V.
Postbus 71
NL-7240 AB Lochem
Telefoon + 31-(0)573-288333
Telefax + 31-(0)573-257319
E-mail general@simco.nl
Internet http://www.simco.nl
Traderegister Apeldoorn No. 08046136
97.52.06.0810 HP-N-Ex 03/092
USER'S MANUAL FOR HP-N-Ex IONISING AIR BLOWER
1. Introduction
Read this manual completely before you install and put this product into use.
This manual is intended as guideline for mounting, installing, and maintenance for skilled
technical people. It should be read in combination with the additional manuals supplied
separately for the P-Sh-N-Ex anti static bar and the radial fan (blower).
Follow the instructions set out in these manuals to ensure proper operation of the product and
to be able to invoke guarantee.
The guarantee terms are stated in the General Conditions for the Sale and Delivery of Products
and/or Performance of Activities by SIMCO (Nederland) B.V.
2. Safety
- The Simco HP-N-Ex Aerostat®
is only intended for neutralizing electro statically charged
parts and/or surfaces.
- When used in potentially explosion hazardous environments: only use the HP-N-Ex
Aerostat®
when the zone classification allows to use equipment as classified through the
marking on the 3 labels on the H-P-N-Ex (classification on page 1 only for reference).
Check the conditions for safe use in the ATEX certificate(s).
- Electrical installation shall be performed by a skilled electrical engineer.
- Make sure that the equipment is properly earthed.
Earthing is needed to ensure proper operation and to avoid electrical shocks upon contact.
- No changes, adjustments, etc. are allowed. When changes, or no original parts have been
used for repairs CE approval and Ex classification for the equipment will be withdrawn and
the equipment will no longer be under guarantee.
3. Use and operation
The Simco HP-N-Ex Aerostat®
is used to neutralize electro statically charged products and/or
surfaces, also at longer distances (1.5 m max.). The ionizing air blower consists of a motor, a
radial fan and an anti-static bar. The ambient air is drawn on one side and blown off along the
anti-static bar. The power unit is integrated in the anti-static bar.
The blower produces an air flow which is rich on positive and negative ions.
When this air flow is pointed to an electro statically charged product or surface, electrons will be
exchanged. This causes the product or material to be neutralized. The effective ionizing width
is 380-580 mm.
The HP-N-Ex Aerostat®
is suited for use in a potentially explosion hazardous environment,
check if the zone where the equipment is going to be used complies with the equipment class.
97.52.06.0810 HP-N-Ex 03/093
4. Technical specifications
Fig. 1 Air flow HP-N-Ex
Aerostat®
HP-N-Ex
Voltage
Frequency
230/400V
50Hz
230/400V
60Hz
254/440V
60Hz
277/480V
60Hz
Blower
Voltage /
Current
Δ 230V AC
0.73A
Δ 230V AC
0.76A
Δ 254V AC
0.76A
Δ 277V AC
0.7A
Υ 400V AC
0.42A
Υ 400V AC
0.44A
Υ 440V AC
0.4A
Υ 480V AC
0.37A
Power out 90W 90W 90W 90W
Protection IP55 IP55 IP55 IP55
Power cable 5m 5m 5m 5m
ATEX category II 2 Gc T4/Ex e II T4 II 2Gc T3/Ex e II T3 II 2Gc T3/Ex e II T3 II 2Gc T3/Ex e II T3
ATEX Certificate PTB02ATEX3114
Anti static bar
Voltage 400V AC 400V AC 440V AC 480V AC
Current 50mA 50mA 50mA 50mA
Frequency 50Hz 60Hz 60Hz 60Hz
Power cable 5m 5m 5m 5m
ATEX category II 2 G Ex smb IIB T4
ATEX Certificate BAS00ATEX2162X
HV signal OK 230V 10mA max
System HP-N-Ex
Working distance: 50 - 1500mm
Working Width 380 mm – 580mm (See diagram)
Weight: 12.5kg
Noise level @ 1m 60dB(A)
Protection IP40
Ambient temperature 0 - 40°C
Air velocity see diagram
97.52.06.0810 HP-N-Ex 03/094
5 Installation
5.1. Checks
- Check if the equipment is undamaged and that you have received the correct version.
- Check if the data on the packing slip corresponds with the data shown on the
product received.
- Check if the voltage shown on the rating plates corresponds with the (mains) voltage you are
going to use.
- Check if the equipment may be used in the environment (Ex-zone).
- Check if there are requirements or instructions in the additional manuals from the attached
ionizing bar, blower and motor.
If you have any problems and/or in the case of ambiguity:
Please contact SIMCO or your regional agent.
5.2. Installation of the HP-N-Ex Aerostat®
5.2.1. Summary
The air flow from the blower must be in a direction between perpendicular to, and at an angle of
approx. 45° in relation to the material.
For maximum ionization the air flow must cover as large a surface as possible. The air flow
direction must preferably be opposite to the material flow direction. In places where the material
is going to be neutralized, it should have a free layer of air. The blower-neutralizing efficiency
will drop dramatically when it blows along metal parts towards the area to be neutralized, as the
ionizing function will be lost.
The effectiveness of the blower depends on the distance to the material, the air flow and the
material speed. The correct position and airflow direction should be established by experiment.
5.2.2. Mounting
Fit the HP-N-Ex, using the extra mounting holes between the blower and the air guide.
5.2.3. Installation of the HP-N-Ex
Warning:
- Electrical installation shall be carried out by a skilled electrical engineer.
- Earth the Aerostat properly: Earthing is required to ensure proper operation of the
equipment and to avoid unpleasant electrical shocks upon contact.
Earthing is provided through both line cords from blower and anti-static bar.
5.3. Installation of the blower
5.3.1 Summary
Each blower motor must be fitted with a suitable protective motor switch. Adjust this switch to
the rated motor current. The switch must be explosion proof or it must be mounted outside the
explosion hazardous zone.
For additional instructions see the manual from the blower: Operating instructions for
radial fans for use in potentially explosive atmospheres.
97.52.06.0810 HP-N-Ex 03/095
5.3.2 Connecting the blower
Connections shall be made in conformity with the applicable local regulations and instructions in
this and the additional manual for the radial fan.
5.3.3. Checking the direction of rotation
− Switch the motor briefly on.
− Check the direction of rotation. It must correspond with the direction shown by the arrow.
− If necessary, change the direction of rotation by interchanging 2 phase wires in the
connection.
5.4 Connecting the P-Sh-N-Ex anti-static bar
The anti-static bar must be connected separately (not through the blower). Check for the mains
voltage on the marking from the P-Sh-N-Ex. The connecting line of the anti-static bar should
contain a fuse. A 230V neon lamp can be fitted as a high-voltage present indicator. Also a relay
can be fitted which triggers an alarm signal if the high voltage fails.
Check for the detailed instructions in the manual supplied with the P-Sh-N-Ex bar.
6. Putting into use
− Switch on the mains voltage from the anti-static bar.
− Switch on the mains voltage from the blower.
7. Functional check
Warning:
− In an explosion-hazardous zone only measuring instruments suited for this zone may
be used.
The neon lamp you fitted (outside the hazardous area) gives an indication of the high voltage.
An electrostatic field meter must be used to measure the efficiency of the anti-static bar.
Measure the charge on the material before and after it has passed the ionising blower.
After passing the blower the charge should be neutralised.
97.52.06.0810 HP-N-Ex 03/096
8. Maintenance
Warning:
− When carrying out work on the equipment: de-energise the equipment.
− Follow instructions belonging to the Ex zone you are working in.
8.1. General maintenance
− Keep the Aerostat®
clean and dry.
− Clean fouled emitter points with a hard non-metallic brush.
Attention:
− Do not damage the emitter points.
9. Faults
9.1. Anti-static bar
Problem Cause Remedy
No/poor ionization Anti-static bar is fouled Clean anti-static bar
Emitter points are covered Remove the cover
Emitter points are damaged Return anti static bar for
repair
No high voltage on emitter
points
No mains voltage on bar Restore mains voltage
Line-side fuse is defective Replace the fuse
Anti-static bar is defective Return anti-static bar for
repair
Table 1 Anti-static bar faults
9.2. Blower
Problem Cause Remedy
Fan does not operate No mains voltage Restore mains voltage
Mains voltage on 2 phase
wires only
Restore mains voltage on
3rd
phase wire
Protective motor switch is off Turn on/reset protective
motor switch, check why it
has switched off
Fan operates in wrong
direction
Fan incorrectly connected Interchange connection of 2
phase wires
Fan does not come up to
speed
Mains voltage on 2 phase
wires only
Restore mains voltage on
3rd
phase wire
No remedy helps Return complete Aerostat
Table 2 Blower faults
97.52.06.0810 HP-N-Ex 03/097
10. Repair
Warning:
− When carrying out work on equipment: de-energise the equipment.
− Repairs shall be made by a skilled electrical engineer.
10.1 Replacing the anti-static bar
1. Disconnect the anti-static bar.
2. Dismount the four screws in the profiles from the bar which connects the bar with the
air guide.
3. Dismount the anti-static bar.
4. Mount a new anti-static bar by fitting the four screws through the profile to the air guide.
5. Route and connect the connection lead.
10.2 Replacing the air guide
1. Dismount and remove the Aerostat®
.
2. Dismount and remove the anti-static bar.
3. Dismount and remove the air guide from the blower.
4. Mount a new air guide.
5. Fit the anti-static bar.
6. Fit the Aerostat®
, using the extra mounting holes between the blower and the air guide.
For other repairs, SIMCO advises you to return the HP-N-Ex
Request an RMA form by sending an e-mail to service@simco.nl.
Pack the HP-N-Ex properly and clearly state the reason for return.
11. Disposal
Adhere to the applicable local environmental and other rules when disposing of the equipment.
12. Spares
Item No. Pos. Description
1590010000 (1) Anti-static bar P-SH-N-Ex, 400 V 50 Hz HP-N-Ex
1590010010 (1) Anti-static bar P-SH-N-Ex, 400 V 60 Hz HP-N-Ex
1590010710 (1) Anti-static bar P-SH-N-Ex, 440 V 60 Hz HP-N-Ex
1590010810 (1) Anti-static bar P-SH-N-Ex, 480 V 60 Hz HP-N-Ex
3610300000 (2) Air guide
6605314860 (3) Blower 230/400 V 50 Hz 3 ph HP-N-Ex
6605314850 (3) Blower 230/400 V 60 Hz 3 ph HP-N-Ex
6605314900 (3) Blower 440 V 60 Hz 3 ph HP-N-Ex
6605314910 (3) Blower 480 V 60 Hz 3 ph HP-N-Ex
97.52.06.0810 HP-N-Ex 03/098
(1)
(2)
(3)
Fig. 2 Spare parts HP-N-Ex
97.52.06.0810 HP-N-Ex 03/099
EC Declaration of Conformity
Manufacturer: Simco (Nederland) B.V.
We declare under our sole responsibility that the product as described, is in conformity with the
following standards.
Product description: Ionising Air Blower consisting out of:
Ionising bar P-Sh-N-Ex and blower DNG-47/S
Type HP-N-Ex
Applicable Directives: EC- Low Voltage Directive (2006/95/EC)
EC- Machinery Directive (98/37/EC)
EC- Electromagnetic compatibility (89/336/EEC)
EC- Potential Explosive Atmospheres ATEX (94/9/EC)
Classified Area: II 2G Ex smb IIB T4 (Bar) 1180
II 2G c T4 / T3 (Blower)
II 2G Ex e II T4 / T3 (Motor) 0102
Notified Body + Certif. nr : Baseefa 1180 BAS00ATEX2162X (blower in var. 4.5)
PTB 0102 PTB02ATEX3114
Used Harmonized Standards: DIN EN 292-1 / DIN-EN292-2: 2000
DIN EN 60204-1: 1998
EN 50081-2: 1993
EN 61000-6-2 2001
EN 60079-0: 2006
DIN EN 60079-10: 1996
EN 60079-18: 2004
DIN EN 1127-1: 1997
DIN EN 13463-1: 2002
DIN EN 13463-5: 2001
DIN EN 14986: 2007
Used National Standards: CSA C22.2 No. 60950-00/UL60950 Third edition
CAN/CSA-C22.2 No. 60950-1-03/UL 60950-1 First edition
SFA 3009: 1985
Place, Date, Signature: Lochem, 02 March 2009,
Position and name: TSQ Manager, B.W. Bel

More Related Content

What's hot

Fr d700
Fr d700Fr d700
Fr d700
Toàn Huỳnh
 
Mitsubishi s500 e-vfd-detailed
Mitsubishi s500 e-vfd-detailedMitsubishi s500 e-vfd-detailed
Mitsubishi s500 e-vfd-detailed
awatori
 
ABB Indoor Current & Voltage Transformers - Instrument Transformers For Indoo...
ABB Indoor Current & Voltage Transformers - Instrument Transformers For Indoo...ABB Indoor Current & Voltage Transformers - Instrument Transformers For Indoo...
ABB Indoor Current & Voltage Transformers - Instrument Transformers For Indoo...
Thorne & Derrick International
 
Fr f700
Fr f700Fr f700
Fr f700
Toàn Huỳnh
 
ABB Low Voltage LV Surge Arresters - ABB LOVOS 5 and LOVOS 10 Surge Arresters
ABB Low Voltage LV Surge Arresters - ABB LOVOS 5 and LOVOS 10 Surge ArrestersABB Low Voltage LV Surge Arresters - ABB LOVOS 5 and LOVOS 10 Surge Arresters
ABB Low Voltage LV Surge Arresters - ABB LOVOS 5 and LOVOS 10 Surge Arresters
Thorne & Derrick International
 
Gabriel Ojeah - HV CONFERENCE POWER POINT - PERTH 2015
Gabriel Ojeah - HV CONFERENCE POWER POINT - PERTH 2015Gabriel Ojeah - HV CONFERENCE POWER POINT - PERTH 2015
Gabriel Ojeah - HV CONFERENCE POWER POINT - PERTH 2015Gabriel Emeka Ojeah
 
Hướng dẫn sử dụng biến tần
Hướng dẫn sử dụng biến tầnHướng dẫn sử dụng biến tần
Hướng dẫn sử dụng biến tần
Hồng Trọng
 
67711911(lj36 b)42ln5460 sm
67711911(lj36 b)42ln5460 sm67711911(lj36 b)42ln5460 sm
67711911(lj36 b)42ln5460 sm
tecxel
 
Mini-Contactors and Thermal Overload Relays - SK Series
Mini-Contactors and Thermal Overload Relays - SK SeriesMini-Contactors and Thermal Overload Relays - SK Series
Mini-Contactors and Thermal Overload Relays - SK Series
CTY TNHH HẠO PHƯƠNG
 
13 l m100-150,cl13m10-15,14ml10
13 l m100-150,cl13m10-15,14ml1013 l m100-150,cl13m10-15,14ml10
13 l m100-150,cl13m10-15,14ml10
Cesar1alex
 
Manual tv lcd da LG RT-15LA70
Manual tv lcd da LG RT-15LA70Manual tv lcd da LG RT-15LA70
Manual tv lcd da LG RT-15LA70
Ronaldo Gama
 
02- Manual Motor Starter - Fuji Electric
02- Manual Motor Starter - Fuji Electric02- Manual Motor Starter - Fuji Electric
02- Manual Motor Starter - Fuji Electric
CTY TNHH HẠO PHƯƠNG
 
01 - Contactor - Fuji Electric
 01 - Contactor - Fuji Electric 01 - Contactor - Fuji Electric
01 - Contactor - Fuji Electric
CTY TNHH HẠO PHƯƠNG
 
Sharp 32 pulg 32c24
Sharp 32 pulg 32c24Sharp 32 pulg 32c24
Sharp 32 pulg 32c24
Irwing Sanchez
 
Lg+42 lt360c+chassis+lb2ac
Lg+42 lt360c+chassis+lb2acLg+42 lt360c+chassis+lb2ac
Lg+42 lt360c+chassis+lb2ac
febriyansyah98
 
03 - Control Relays & Timer - Fuji Electric
03 - Control Relays & Timer - Fuji Electric03 - Control Relays & Timer - Fuji Electric
03 - Control Relays & Timer - Fuji Electric
CTY TNHH HẠO PHƯƠNG
 
Fuji sc and sw series contactors
Fuji sc and sw series contactorsFuji sc and sw series contactors
Fuji sc and sw series contactorsEko Kiswanto
 

What's hot (18)

Fr d700
Fr d700Fr d700
Fr d700
 
Mitsubishi s500 e-vfd-detailed
Mitsubishi s500 e-vfd-detailedMitsubishi s500 e-vfd-detailed
Mitsubishi s500 e-vfd-detailed
 
ABB Indoor Current & Voltage Transformers - Instrument Transformers For Indoo...
ABB Indoor Current & Voltage Transformers - Instrument Transformers For Indoo...ABB Indoor Current & Voltage Transformers - Instrument Transformers For Indoo...
ABB Indoor Current & Voltage Transformers - Instrument Transformers For Indoo...
 
Fr f700
Fr f700Fr f700
Fr f700
 
ABB Low Voltage LV Surge Arresters - ABB LOVOS 5 and LOVOS 10 Surge Arresters
ABB Low Voltage LV Surge Arresters - ABB LOVOS 5 and LOVOS 10 Surge ArrestersABB Low Voltage LV Surge Arresters - ABB LOVOS 5 and LOVOS 10 Surge Arresters
ABB Low Voltage LV Surge Arresters - ABB LOVOS 5 and LOVOS 10 Surge Arresters
 
Gabriel Ojeah - HV CONFERENCE POWER POINT - PERTH 2015
Gabriel Ojeah - HV CONFERENCE POWER POINT - PERTH 2015Gabriel Ojeah - HV CONFERENCE POWER POINT - PERTH 2015
Gabriel Ojeah - HV CONFERENCE POWER POINT - PERTH 2015
 
Hướng dẫn sử dụng biến tần
Hướng dẫn sử dụng biến tầnHướng dẫn sử dụng biến tần
Hướng dẫn sử dụng biến tần
 
67711911(lj36 b)42ln5460 sm
67711911(lj36 b)42ln5460 sm67711911(lj36 b)42ln5460 sm
67711911(lj36 b)42ln5460 sm
 
Mini-Contactors and Thermal Overload Relays - SK Series
Mini-Contactors and Thermal Overload Relays - SK SeriesMini-Contactors and Thermal Overload Relays - SK Series
Mini-Contactors and Thermal Overload Relays - SK Series
 
13 l m100-150,cl13m10-15,14ml10
13 l m100-150,cl13m10-15,14ml1013 l m100-150,cl13m10-15,14ml10
13 l m100-150,cl13m10-15,14ml10
 
Manual tv lcd da LG RT-15LA70
Manual tv lcd da LG RT-15LA70Manual tv lcd da LG RT-15LA70
Manual tv lcd da LG RT-15LA70
 
02- Manual Motor Starter - Fuji Electric
02- Manual Motor Starter - Fuji Electric02- Manual Motor Starter - Fuji Electric
02- Manual Motor Starter - Fuji Electric
 
01 - Contactor - Fuji Electric
 01 - Contactor - Fuji Electric 01 - Contactor - Fuji Electric
01 - Contactor - Fuji Electric
 
Sharp 32 pulg 32c24
Sharp 32 pulg 32c24Sharp 32 pulg 32c24
Sharp 32 pulg 32c24
 
Lg+42 lt360c+chassis+lb2ac
Lg+42 lt360c+chassis+lb2acLg+42 lt360c+chassis+lb2ac
Lg+42 lt360c+chassis+lb2ac
 
03 - Control Relays & Timer - Fuji Electric
03 - Control Relays & Timer - Fuji Electric03 - Control Relays & Timer - Fuji Electric
03 - Control Relays & Timer - Fuji Electric
 
Thông số kĩ thuật siemens contactor 3 rt
Thông số kĩ thuật siemens contactor 3 rtThông số kĩ thuật siemens contactor 3 rt
Thông số kĩ thuật siemens contactor 3 rt
 
Fuji sc and sw series contactors
Fuji sc and sw series contactorsFuji sc and sw series contactors
Fuji sc and sw series contactors
 

Similar to Airblower hp n-ex-eng

sharp_14mn10_ch_sn-000.pptx
sharp_14mn10_ch_sn-000.pptxsharp_14mn10_ch_sn-000.pptx
sharp_14mn10_ch_sn-000.pptx
ssuser27df19
 
Jvc mx g75v-g78v_gt85v_gt88v_gt95v_gt98v
Jvc mx g75v-g78v_gt85v_gt88v_gt95v_gt98vJvc mx g75v-g78v_gt85v_gt88v_gt95v_gt98v
Jvc mx g75v-g78v_gt85v_gt88v_gt95v_gt98vsophon505
 
Replacing antenna integrated radio units air32
Replacing antenna integrated radio units air32Replacing antenna integrated radio units air32
Replacing antenna integrated radio units air32
Roberto Rojas
 
Fuji frenic-5000 g11s-p11s-user-manual
Fuji frenic-5000 g11s-p11s-user-manualFuji frenic-5000 g11s-p11s-user-manual
Fuji frenic-5000 g11s-p11s-user-manual
Toàn Huỳnh
 
Studer Vista 5 M2 - User Manual
Studer Vista 5 M2 - User ManualStuder Vista 5 M2 - User Manual
Studer Vista 5 M2 - User Manual
Marcos Cunha
 
Lg 42lw5700 da-chassis_lt12c_mfl67007911_1103-rev00
Lg 42lw5700 da-chassis_lt12c_mfl67007911_1103-rev00Lg 42lw5700 da-chassis_lt12c_mfl67007911_1103-rev00
Lg 42lw5700 da-chassis_lt12c_mfl67007911_1103-rev00
Arturo Nava Hernandez
 
Catalog FR-D700 Instruction manual (applied)-Beeteco.com
Catalog FR-D700 Instruction manual (applied)-Beeteco.comCatalog FR-D700 Instruction manual (applied)-Beeteco.com
Catalog FR-D700 Instruction manual (applied)-Beeteco.com
Beeteco
 
Manual de serviço TV LED LG 22LN4050TB chassis LB35A.
Manual de serviço TV LED LG 22LN4050TB chassis LB35A.Manual de serviço TV LED LG 22LN4050TB chassis LB35A.
Manual de serviço TV LED LG 22LN4050TB chassis LB35A.
Portal Eletrônica
 
Valtek Beta NT3000 Flowserve
Valtek Beta NT3000 FlowserveValtek Beta NT3000 Flowserve
Valtek Beta NT3000 FlowserveIr. Hadi Budiman
 
Hazloc AEU1 Air Heater - Hazardous Area Explosion Proof ATEX Zone 1 Certified
Hazloc AEU1 Air Heater - Hazardous Area Explosion Proof ATEX Zone 1 CertifiedHazloc AEU1 Air Heater - Hazardous Area Explosion Proof ATEX Zone 1 Certified
Hazloc AEU1 Air Heater - Hazardous Area Explosion Proof ATEX Zone 1 Certified
Thorne & Derrick International
 
Lg 32 lk330u +chasis+ld01u
Lg 32 lk330u +chasis+ld01uLg 32 lk330u +chasis+ld01u
Lg 32 lk330u +chasis+ld01u
edy rod
 
MA-2402-Manual-127240.pdf
MA-2402-Manual-127240.pdfMA-2402-Manual-127240.pdf
MA-2402-Manual-127240.pdf
CREST2020
 
Fr f700
Fr f700Fr f700
Fr f700
Toàn Huỳnh
 
Fr f700
Fr f700Fr f700
Fr f700
Toàn Huỳnh
 
Manual de serviço tv led samsung ua32 f5500 chassis u85a
Manual de serviço tv led samsung ua32 f5500 chassis u85aManual de serviço tv led samsung ua32 f5500 chassis u85a
Manual de serviço tv led samsung ua32 f5500 chassis u85a
Portal Eletrônica
 
Solar Edge Load Switching Devices
Solar Edge Load Switching Devices Solar Edge Load Switching Devices
Solar Edge Load Switching Devices
Optimus Energy Philippines
 
Electrical and electronics Lab Manual
Electrical and electronics Lab ManualElectrical and electronics Lab Manual
Electrical and electronics Lab Manual
Sachin Airan
 
JVC RM-LP25U Remote Control Panel
JVC RM-LP25U Remote Control PanelJVC RM-LP25U Remote Control Panel
JVC RM-LP25U Remote Control Panel
AV ProfShop
 
CE-2000TX-Operation-Manual-126991.powerpdf
CE-2000TX-Operation-Manual-126991.powerpdfCE-2000TX-Operation-Manual-126991.powerpdf
CE-2000TX-Operation-Manual-126991.powerpdf
ArnelIbanez1
 

Similar to Airblower hp n-ex-eng (20)

sharp_14mn10_ch_sn-000.pptx
sharp_14mn10_ch_sn-000.pptxsharp_14mn10_ch_sn-000.pptx
sharp_14mn10_ch_sn-000.pptx
 
Jvc mx g75v-g78v_gt85v_gt88v_gt95v_gt98v
Jvc mx g75v-g78v_gt85v_gt88v_gt95v_gt98vJvc mx g75v-g78v_gt85v_gt88v_gt95v_gt98v
Jvc mx g75v-g78v_gt85v_gt88v_gt95v_gt98v
 
Wp series manual
Wp series manualWp series manual
Wp series manual
 
Replacing antenna integrated radio units air32
Replacing antenna integrated radio units air32Replacing antenna integrated radio units air32
Replacing antenna integrated radio units air32
 
Fuji frenic-5000 g11s-p11s-user-manual
Fuji frenic-5000 g11s-p11s-user-manualFuji frenic-5000 g11s-p11s-user-manual
Fuji frenic-5000 g11s-p11s-user-manual
 
Studer Vista 5 M2 - User Manual
Studer Vista 5 M2 - User ManualStuder Vista 5 M2 - User Manual
Studer Vista 5 M2 - User Manual
 
Lg 42lw5700 da-chassis_lt12c_mfl67007911_1103-rev00
Lg 42lw5700 da-chassis_lt12c_mfl67007911_1103-rev00Lg 42lw5700 da-chassis_lt12c_mfl67007911_1103-rev00
Lg 42lw5700 da-chassis_lt12c_mfl67007911_1103-rev00
 
Catalog FR-D700 Instruction manual (applied)-Beeteco.com
Catalog FR-D700 Instruction manual (applied)-Beeteco.comCatalog FR-D700 Instruction manual (applied)-Beeteco.com
Catalog FR-D700 Instruction manual (applied)-Beeteco.com
 
Manual de serviço TV LED LG 22LN4050TB chassis LB35A.
Manual de serviço TV LED LG 22LN4050TB chassis LB35A.Manual de serviço TV LED LG 22LN4050TB chassis LB35A.
Manual de serviço TV LED LG 22LN4050TB chassis LB35A.
 
Valtek Beta NT3000 Flowserve
Valtek Beta NT3000 FlowserveValtek Beta NT3000 Flowserve
Valtek Beta NT3000 Flowserve
 
Hazloc AEU1 Air Heater - Hazardous Area Explosion Proof ATEX Zone 1 Certified
Hazloc AEU1 Air Heater - Hazardous Area Explosion Proof ATEX Zone 1 CertifiedHazloc AEU1 Air Heater - Hazardous Area Explosion Proof ATEX Zone 1 Certified
Hazloc AEU1 Air Heater - Hazardous Area Explosion Proof ATEX Zone 1 Certified
 
Lg 32 lk330u +chasis+ld01u
Lg 32 lk330u +chasis+ld01uLg 32 lk330u +chasis+ld01u
Lg 32 lk330u +chasis+ld01u
 
MA-2402-Manual-127240.pdf
MA-2402-Manual-127240.pdfMA-2402-Manual-127240.pdf
MA-2402-Manual-127240.pdf
 
Fr f700
Fr f700Fr f700
Fr f700
 
Fr f700
Fr f700Fr f700
Fr f700
 
Manual de serviço tv led samsung ua32 f5500 chassis u85a
Manual de serviço tv led samsung ua32 f5500 chassis u85aManual de serviço tv led samsung ua32 f5500 chassis u85a
Manual de serviço tv led samsung ua32 f5500 chassis u85a
 
Solar Edge Load Switching Devices
Solar Edge Load Switching Devices Solar Edge Load Switching Devices
Solar Edge Load Switching Devices
 
Electrical and electronics Lab Manual
Electrical and electronics Lab ManualElectrical and electronics Lab Manual
Electrical and electronics Lab Manual
 
JVC RM-LP25U Remote Control Panel
JVC RM-LP25U Remote Control PanelJVC RM-LP25U Remote Control Panel
JVC RM-LP25U Remote Control Panel
 
CE-2000TX-Operation-Manual-126991.powerpdf
CE-2000TX-Operation-Manual-126991.powerpdfCE-2000TX-Operation-Manual-126991.powerpdf
CE-2000TX-Operation-Manual-126991.powerpdf
 

More from ducnamtrinh

High performance foil rotor improves de ink pulp screen
High performance foil rotor improves de ink pulp screenHigh performance foil rotor improves de ink pulp screen
High performance foil rotor improves de ink pulp screen
ducnamtrinh
 
Accounting succinctly
Accounting succinctlyAccounting succinctly
Accounting succinctly
ducnamtrinh
 
Steam trap-handbook-2
Steam trap-handbook-2Steam trap-handbook-2
Steam trap-handbook-2
ducnamtrinh
 
Bearing handbook for electric motor skf
Bearing handbook for electric motor skfBearing handbook for electric motor skf
Bearing handbook for electric motor skf
ducnamtrinh
 
Dien - Khi nen SMC
Dien - Khi nen SMCDien - Khi nen SMC
Dien - Khi nen SMC
ducnamtrinh
 
Quat ly tam centrifugal fan
Quat ly tam  centrifugal fanQuat ly tam  centrifugal fan
Quat ly tam centrifugal fanducnamtrinh
 

More from ducnamtrinh (7)

High performance foil rotor improves de ink pulp screen
High performance foil rotor improves de ink pulp screenHigh performance foil rotor improves de ink pulp screen
High performance foil rotor improves de ink pulp screen
 
Accounting succinctly
Accounting succinctlyAccounting succinctly
Accounting succinctly
 
Steam trap-handbook-2
Steam trap-handbook-2Steam trap-handbook-2
Steam trap-handbook-2
 
Bearing handbook for electric motor skf
Bearing handbook for electric motor skfBearing handbook for electric motor skf
Bearing handbook for electric motor skf
 
Dien - Khi nen SMC
Dien - Khi nen SMCDien - Khi nen SMC
Dien - Khi nen SMC
 
Quat ly tam centrifugal fan
Quat ly tam  centrifugal fanQuat ly tam  centrifugal fan
Quat ly tam centrifugal fan
 
Han tig
Han tigHan tig
Han tig
 

Recently uploaded

在线办理(ANU毕业证书)澳洲国立大学毕业证录取通知书一模一样
在线办理(ANU毕业证书)澳洲国立大学毕业证录取通知书一模一样在线办理(ANU毕业证书)澳洲国立大学毕业证录取通知书一模一样
在线办理(ANU毕业证书)澳洲国立大学毕业证录取通知书一模一样
obonagu
 
Fundamentals of Induction Motor Drives.pptx
Fundamentals of Induction Motor Drives.pptxFundamentals of Induction Motor Drives.pptx
Fundamentals of Induction Motor Drives.pptx
manasideore6
 
Harnessing WebAssembly for Real-time Stateless Streaming Pipelines
Harnessing WebAssembly for Real-time Stateless Streaming PipelinesHarnessing WebAssembly for Real-time Stateless Streaming Pipelines
Harnessing WebAssembly for Real-time Stateless Streaming Pipelines
Christina Lin
 
Tutorial for 16S rRNA Gene Analysis with QIIME2.pdf
Tutorial for 16S rRNA Gene Analysis with QIIME2.pdfTutorial for 16S rRNA Gene Analysis with QIIME2.pdf
Tutorial for 16S rRNA Gene Analysis with QIIME2.pdf
aqil azizi
 
Planning Of Procurement o different goods and services
Planning Of Procurement o different goods and servicesPlanning Of Procurement o different goods and services
Planning Of Procurement o different goods and services
JoytuBarua2
 
basic-wireline-operations-course-mahmoud-f-radwan.pdf
basic-wireline-operations-course-mahmoud-f-radwan.pdfbasic-wireline-operations-course-mahmoud-f-radwan.pdf
basic-wireline-operations-course-mahmoud-f-radwan.pdf
NidhalKahouli2
 
6th International Conference on Machine Learning & Applications (CMLA 2024)
6th International Conference on Machine Learning & Applications (CMLA 2024)6th International Conference on Machine Learning & Applications (CMLA 2024)
6th International Conference on Machine Learning & Applications (CMLA 2024)
ClaraZara1
 
RAT: Retrieval Augmented Thoughts Elicit Context-Aware Reasoning in Long-Hori...
RAT: Retrieval Augmented Thoughts Elicit Context-Aware Reasoning in Long-Hori...RAT: Retrieval Augmented Thoughts Elicit Context-Aware Reasoning in Long-Hori...
RAT: Retrieval Augmented Thoughts Elicit Context-Aware Reasoning in Long-Hori...
thanhdowork
 
bank management system in java and mysql report1.pdf
bank management system in java and mysql report1.pdfbank management system in java and mysql report1.pdf
bank management system in java and mysql report1.pdf
Divyam548318
 
DfMAy 2024 - key insights and contributions
DfMAy 2024 - key insights and contributionsDfMAy 2024 - key insights and contributions
DfMAy 2024 - key insights and contributions
gestioneergodomus
 
ACEP Magazine edition 4th launched on 05.06.2024
ACEP Magazine edition 4th launched on 05.06.2024ACEP Magazine edition 4th launched on 05.06.2024
ACEP Magazine edition 4th launched on 05.06.2024
Rahul
 
Fundamentals of Electric Drives and its applications.pptx
Fundamentals of Electric Drives and its applications.pptxFundamentals of Electric Drives and its applications.pptx
Fundamentals of Electric Drives and its applications.pptx
manasideore6
 
Technical Drawings introduction to drawing of prisms
Technical Drawings introduction to drawing of prismsTechnical Drawings introduction to drawing of prisms
Technical Drawings introduction to drawing of prisms
heavyhaig
 
Building Electrical System Design & Installation
Building Electrical System Design & InstallationBuilding Electrical System Design & Installation
Building Electrical System Design & Installation
symbo111
 
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
ihlasbinance2003
 
14 Template Contractual Notice - EOT Application
14 Template Contractual Notice - EOT Application14 Template Contractual Notice - EOT Application
14 Template Contractual Notice - EOT Application
SyedAbiiAzazi1
 
digital fundamental by Thomas L.floydl.pdf
digital fundamental by Thomas L.floydl.pdfdigital fundamental by Thomas L.floydl.pdf
digital fundamental by Thomas L.floydl.pdf
drwaing
 
Understanding Inductive Bias in Machine Learning
Understanding Inductive Bias in Machine LearningUnderstanding Inductive Bias in Machine Learning
Understanding Inductive Bias in Machine Learning
SUTEJAS
 
一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
ydteq
 
Modelagem de um CSTR com reação endotermica.pdf
Modelagem de um CSTR com reação endotermica.pdfModelagem de um CSTR com reação endotermica.pdf
Modelagem de um CSTR com reação endotermica.pdf
camseq
 

Recently uploaded (20)

在线办理(ANU毕业证书)澳洲国立大学毕业证录取通知书一模一样
在线办理(ANU毕业证书)澳洲国立大学毕业证录取通知书一模一样在线办理(ANU毕业证书)澳洲国立大学毕业证录取通知书一模一样
在线办理(ANU毕业证书)澳洲国立大学毕业证录取通知书一模一样
 
Fundamentals of Induction Motor Drives.pptx
Fundamentals of Induction Motor Drives.pptxFundamentals of Induction Motor Drives.pptx
Fundamentals of Induction Motor Drives.pptx
 
Harnessing WebAssembly for Real-time Stateless Streaming Pipelines
Harnessing WebAssembly for Real-time Stateless Streaming PipelinesHarnessing WebAssembly for Real-time Stateless Streaming Pipelines
Harnessing WebAssembly for Real-time Stateless Streaming Pipelines
 
Tutorial for 16S rRNA Gene Analysis with QIIME2.pdf
Tutorial for 16S rRNA Gene Analysis with QIIME2.pdfTutorial for 16S rRNA Gene Analysis with QIIME2.pdf
Tutorial for 16S rRNA Gene Analysis with QIIME2.pdf
 
Planning Of Procurement o different goods and services
Planning Of Procurement o different goods and servicesPlanning Of Procurement o different goods and services
Planning Of Procurement o different goods and services
 
basic-wireline-operations-course-mahmoud-f-radwan.pdf
basic-wireline-operations-course-mahmoud-f-radwan.pdfbasic-wireline-operations-course-mahmoud-f-radwan.pdf
basic-wireline-operations-course-mahmoud-f-radwan.pdf
 
6th International Conference on Machine Learning & Applications (CMLA 2024)
6th International Conference on Machine Learning & Applications (CMLA 2024)6th International Conference on Machine Learning & Applications (CMLA 2024)
6th International Conference on Machine Learning & Applications (CMLA 2024)
 
RAT: Retrieval Augmented Thoughts Elicit Context-Aware Reasoning in Long-Hori...
RAT: Retrieval Augmented Thoughts Elicit Context-Aware Reasoning in Long-Hori...RAT: Retrieval Augmented Thoughts Elicit Context-Aware Reasoning in Long-Hori...
RAT: Retrieval Augmented Thoughts Elicit Context-Aware Reasoning in Long-Hori...
 
bank management system in java and mysql report1.pdf
bank management system in java and mysql report1.pdfbank management system in java and mysql report1.pdf
bank management system in java and mysql report1.pdf
 
DfMAy 2024 - key insights and contributions
DfMAy 2024 - key insights and contributionsDfMAy 2024 - key insights and contributions
DfMAy 2024 - key insights and contributions
 
ACEP Magazine edition 4th launched on 05.06.2024
ACEP Magazine edition 4th launched on 05.06.2024ACEP Magazine edition 4th launched on 05.06.2024
ACEP Magazine edition 4th launched on 05.06.2024
 
Fundamentals of Electric Drives and its applications.pptx
Fundamentals of Electric Drives and its applications.pptxFundamentals of Electric Drives and its applications.pptx
Fundamentals of Electric Drives and its applications.pptx
 
Technical Drawings introduction to drawing of prisms
Technical Drawings introduction to drawing of prismsTechnical Drawings introduction to drawing of prisms
Technical Drawings introduction to drawing of prisms
 
Building Electrical System Design & Installation
Building Electrical System Design & InstallationBuilding Electrical System Design & Installation
Building Electrical System Design & Installation
 
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
 
14 Template Contractual Notice - EOT Application
14 Template Contractual Notice - EOT Application14 Template Contractual Notice - EOT Application
14 Template Contractual Notice - EOT Application
 
digital fundamental by Thomas L.floydl.pdf
digital fundamental by Thomas L.floydl.pdfdigital fundamental by Thomas L.floydl.pdf
digital fundamental by Thomas L.floydl.pdf
 
Understanding Inductive Bias in Machine Learning
Understanding Inductive Bias in Machine LearningUnderstanding Inductive Bias in Machine Learning
Understanding Inductive Bias in Machine Learning
 
一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
 
Modelagem de um CSTR com reação endotermica.pdf
Modelagem de um CSTR com reação endotermica.pdfModelagem de um CSTR com reação endotermica.pdf
Modelagem de um CSTR com reação endotermica.pdf
 

Airblower hp n-ex-eng

  • 1. 97.52.06.0810 HP-N-Ex 03/091 AEROSTAT® HP-N-Ex Ionising Air Blower User’s Manual UK CONTENTS Page 1. Introduction 2 2. Safety 2 3. Use and operation 2 4. Technical specifications 3 5. Installation 4 6. Putting into use 5 7. Functional check 5 8. Maintenance 6 9. Faults 6 10. Repair 7 11. Disposal 7 12. Spares 7 CE declaration 9 1180 BAS00ATEX2162X II 2G Ex smb IIB T4 (Bar) II 2G c T4 / T3 (Blower) II 2G Ex e II T4 / T3 (Motor) SIMCO (Nederland) B.V. Postbus 71 NL-7240 AB Lochem Telefoon + 31-(0)573-288333 Telefax + 31-(0)573-257319 E-mail general@simco.nl Internet http://www.simco.nl Traderegister Apeldoorn No. 08046136
  • 2. 97.52.06.0810 HP-N-Ex 03/092 USER'S MANUAL FOR HP-N-Ex IONISING AIR BLOWER 1. Introduction Read this manual completely before you install and put this product into use. This manual is intended as guideline for mounting, installing, and maintenance for skilled technical people. It should be read in combination with the additional manuals supplied separately for the P-Sh-N-Ex anti static bar and the radial fan (blower). Follow the instructions set out in these manuals to ensure proper operation of the product and to be able to invoke guarantee. The guarantee terms are stated in the General Conditions for the Sale and Delivery of Products and/or Performance of Activities by SIMCO (Nederland) B.V. 2. Safety - The Simco HP-N-Ex Aerostat® is only intended for neutralizing electro statically charged parts and/or surfaces. - When used in potentially explosion hazardous environments: only use the HP-N-Ex Aerostat® when the zone classification allows to use equipment as classified through the marking on the 3 labels on the H-P-N-Ex (classification on page 1 only for reference). Check the conditions for safe use in the ATEX certificate(s). - Electrical installation shall be performed by a skilled electrical engineer. - Make sure that the equipment is properly earthed. Earthing is needed to ensure proper operation and to avoid electrical shocks upon contact. - No changes, adjustments, etc. are allowed. When changes, or no original parts have been used for repairs CE approval and Ex classification for the equipment will be withdrawn and the equipment will no longer be under guarantee. 3. Use and operation The Simco HP-N-Ex Aerostat® is used to neutralize electro statically charged products and/or surfaces, also at longer distances (1.5 m max.). The ionizing air blower consists of a motor, a radial fan and an anti-static bar. The ambient air is drawn on one side and blown off along the anti-static bar. The power unit is integrated in the anti-static bar. The blower produces an air flow which is rich on positive and negative ions. When this air flow is pointed to an electro statically charged product or surface, electrons will be exchanged. This causes the product or material to be neutralized. The effective ionizing width is 380-580 mm. The HP-N-Ex Aerostat® is suited for use in a potentially explosion hazardous environment, check if the zone where the equipment is going to be used complies with the equipment class.
  • 3. 97.52.06.0810 HP-N-Ex 03/093 4. Technical specifications Fig. 1 Air flow HP-N-Ex Aerostat® HP-N-Ex Voltage Frequency 230/400V 50Hz 230/400V 60Hz 254/440V 60Hz 277/480V 60Hz Blower Voltage / Current Δ 230V AC 0.73A Δ 230V AC 0.76A Δ 254V AC 0.76A Δ 277V AC 0.7A Υ 400V AC 0.42A Υ 400V AC 0.44A Υ 440V AC 0.4A Υ 480V AC 0.37A Power out 90W 90W 90W 90W Protection IP55 IP55 IP55 IP55 Power cable 5m 5m 5m 5m ATEX category II 2 Gc T4/Ex e II T4 II 2Gc T3/Ex e II T3 II 2Gc T3/Ex e II T3 II 2Gc T3/Ex e II T3 ATEX Certificate PTB02ATEX3114 Anti static bar Voltage 400V AC 400V AC 440V AC 480V AC Current 50mA 50mA 50mA 50mA Frequency 50Hz 60Hz 60Hz 60Hz Power cable 5m 5m 5m 5m ATEX category II 2 G Ex smb IIB T4 ATEX Certificate BAS00ATEX2162X HV signal OK 230V 10mA max System HP-N-Ex Working distance: 50 - 1500mm Working Width 380 mm – 580mm (See diagram) Weight: 12.5kg Noise level @ 1m 60dB(A) Protection IP40 Ambient temperature 0 - 40°C Air velocity see diagram
  • 4. 97.52.06.0810 HP-N-Ex 03/094 5 Installation 5.1. Checks - Check if the equipment is undamaged and that you have received the correct version. - Check if the data on the packing slip corresponds with the data shown on the product received. - Check if the voltage shown on the rating plates corresponds with the (mains) voltage you are going to use. - Check if the equipment may be used in the environment (Ex-zone). - Check if there are requirements or instructions in the additional manuals from the attached ionizing bar, blower and motor. If you have any problems and/or in the case of ambiguity: Please contact SIMCO or your regional agent. 5.2. Installation of the HP-N-Ex Aerostat® 5.2.1. Summary The air flow from the blower must be in a direction between perpendicular to, and at an angle of approx. 45° in relation to the material. For maximum ionization the air flow must cover as large a surface as possible. The air flow direction must preferably be opposite to the material flow direction. In places where the material is going to be neutralized, it should have a free layer of air. The blower-neutralizing efficiency will drop dramatically when it blows along metal parts towards the area to be neutralized, as the ionizing function will be lost. The effectiveness of the blower depends on the distance to the material, the air flow and the material speed. The correct position and airflow direction should be established by experiment. 5.2.2. Mounting Fit the HP-N-Ex, using the extra mounting holes between the blower and the air guide. 5.2.3. Installation of the HP-N-Ex Warning: - Electrical installation shall be carried out by a skilled electrical engineer. - Earth the Aerostat properly: Earthing is required to ensure proper operation of the equipment and to avoid unpleasant electrical shocks upon contact. Earthing is provided through both line cords from blower and anti-static bar. 5.3. Installation of the blower 5.3.1 Summary Each blower motor must be fitted with a suitable protective motor switch. Adjust this switch to the rated motor current. The switch must be explosion proof or it must be mounted outside the explosion hazardous zone. For additional instructions see the manual from the blower: Operating instructions for radial fans for use in potentially explosive atmospheres.
  • 5. 97.52.06.0810 HP-N-Ex 03/095 5.3.2 Connecting the blower Connections shall be made in conformity with the applicable local regulations and instructions in this and the additional manual for the radial fan. 5.3.3. Checking the direction of rotation − Switch the motor briefly on. − Check the direction of rotation. It must correspond with the direction shown by the arrow. − If necessary, change the direction of rotation by interchanging 2 phase wires in the connection. 5.4 Connecting the P-Sh-N-Ex anti-static bar The anti-static bar must be connected separately (not through the blower). Check for the mains voltage on the marking from the P-Sh-N-Ex. The connecting line of the anti-static bar should contain a fuse. A 230V neon lamp can be fitted as a high-voltage present indicator. Also a relay can be fitted which triggers an alarm signal if the high voltage fails. Check for the detailed instructions in the manual supplied with the P-Sh-N-Ex bar. 6. Putting into use − Switch on the mains voltage from the anti-static bar. − Switch on the mains voltage from the blower. 7. Functional check Warning: − In an explosion-hazardous zone only measuring instruments suited for this zone may be used. The neon lamp you fitted (outside the hazardous area) gives an indication of the high voltage. An electrostatic field meter must be used to measure the efficiency of the anti-static bar. Measure the charge on the material before and after it has passed the ionising blower. After passing the blower the charge should be neutralised.
  • 6. 97.52.06.0810 HP-N-Ex 03/096 8. Maintenance Warning: − When carrying out work on the equipment: de-energise the equipment. − Follow instructions belonging to the Ex zone you are working in. 8.1. General maintenance − Keep the Aerostat® clean and dry. − Clean fouled emitter points with a hard non-metallic brush. Attention: − Do not damage the emitter points. 9. Faults 9.1. Anti-static bar Problem Cause Remedy No/poor ionization Anti-static bar is fouled Clean anti-static bar Emitter points are covered Remove the cover Emitter points are damaged Return anti static bar for repair No high voltage on emitter points No mains voltage on bar Restore mains voltage Line-side fuse is defective Replace the fuse Anti-static bar is defective Return anti-static bar for repair Table 1 Anti-static bar faults 9.2. Blower Problem Cause Remedy Fan does not operate No mains voltage Restore mains voltage Mains voltage on 2 phase wires only Restore mains voltage on 3rd phase wire Protective motor switch is off Turn on/reset protective motor switch, check why it has switched off Fan operates in wrong direction Fan incorrectly connected Interchange connection of 2 phase wires Fan does not come up to speed Mains voltage on 2 phase wires only Restore mains voltage on 3rd phase wire No remedy helps Return complete Aerostat Table 2 Blower faults
  • 7. 97.52.06.0810 HP-N-Ex 03/097 10. Repair Warning: − When carrying out work on equipment: de-energise the equipment. − Repairs shall be made by a skilled electrical engineer. 10.1 Replacing the anti-static bar 1. Disconnect the anti-static bar. 2. Dismount the four screws in the profiles from the bar which connects the bar with the air guide. 3. Dismount the anti-static bar. 4. Mount a new anti-static bar by fitting the four screws through the profile to the air guide. 5. Route and connect the connection lead. 10.2 Replacing the air guide 1. Dismount and remove the Aerostat® . 2. Dismount and remove the anti-static bar. 3. Dismount and remove the air guide from the blower. 4. Mount a new air guide. 5. Fit the anti-static bar. 6. Fit the Aerostat® , using the extra mounting holes between the blower and the air guide. For other repairs, SIMCO advises you to return the HP-N-Ex Request an RMA form by sending an e-mail to service@simco.nl. Pack the HP-N-Ex properly and clearly state the reason for return. 11. Disposal Adhere to the applicable local environmental and other rules when disposing of the equipment. 12. Spares Item No. Pos. Description 1590010000 (1) Anti-static bar P-SH-N-Ex, 400 V 50 Hz HP-N-Ex 1590010010 (1) Anti-static bar P-SH-N-Ex, 400 V 60 Hz HP-N-Ex 1590010710 (1) Anti-static bar P-SH-N-Ex, 440 V 60 Hz HP-N-Ex 1590010810 (1) Anti-static bar P-SH-N-Ex, 480 V 60 Hz HP-N-Ex 3610300000 (2) Air guide 6605314860 (3) Blower 230/400 V 50 Hz 3 ph HP-N-Ex 6605314850 (3) Blower 230/400 V 60 Hz 3 ph HP-N-Ex 6605314900 (3) Blower 440 V 60 Hz 3 ph HP-N-Ex 6605314910 (3) Blower 480 V 60 Hz 3 ph HP-N-Ex
  • 9. 97.52.06.0810 HP-N-Ex 03/099 EC Declaration of Conformity Manufacturer: Simco (Nederland) B.V. We declare under our sole responsibility that the product as described, is in conformity with the following standards. Product description: Ionising Air Blower consisting out of: Ionising bar P-Sh-N-Ex and blower DNG-47/S Type HP-N-Ex Applicable Directives: EC- Low Voltage Directive (2006/95/EC) EC- Machinery Directive (98/37/EC) EC- Electromagnetic compatibility (89/336/EEC) EC- Potential Explosive Atmospheres ATEX (94/9/EC) Classified Area: II 2G Ex smb IIB T4 (Bar) 1180 II 2G c T4 / T3 (Blower) II 2G Ex e II T4 / T3 (Motor) 0102 Notified Body + Certif. nr : Baseefa 1180 BAS00ATEX2162X (blower in var. 4.5) PTB 0102 PTB02ATEX3114 Used Harmonized Standards: DIN EN 292-1 / DIN-EN292-2: 2000 DIN EN 60204-1: 1998 EN 50081-2: 1993 EN 61000-6-2 2001 EN 60079-0: 2006 DIN EN 60079-10: 1996 EN 60079-18: 2004 DIN EN 1127-1: 1997 DIN EN 13463-1: 2002 DIN EN 13463-5: 2001 DIN EN 14986: 2007 Used National Standards: CSA C22.2 No. 60950-00/UL60950 Third edition CAN/CSA-C22.2 No. 60950-1-03/UL 60950-1 First edition SFA 3009: 1985 Place, Date, Signature: Lochem, 02 March 2009, Position and name: TSQ Manager, B.W. Bel