1 MASTER ANGLED TOP 430 3700 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON
Mark Location Window Style Width Height Material Glazing Remarks
Custom Window Schedule(All windows to be supplied by Stegbar)
2 MASTER ANGLED TOP 430 5720 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON
3 ENTRY RECTANGLE 640 140 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON
7 LIVING PARALLELOGRAM 2970 335 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON
10 DINING RIGHT ANGLE 3975 505 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON
4 ENTRY RECTANGLE 640 140 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON
5 ENTRY RECTANGLE 640 140 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON
6 ENTRY RECTANGLE 640 140 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON
8 STUDY ANGLED TOP 560 5000 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON
9 STUDY ANGLED TOP 560 3480 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON
AWNING
AWNING
AWNING
AWNING
AWNING
AWNING
AWNING
AWNING
AWNING
FIXED
CUSTOM WINDOWS
WINDOW SCHEDULE
DOOR SCHEDULEgeneral notes
N1 USE WRITTEN DIMENSIONS WHERE GIVEN OVER SCALE
N2 THESE PLANS ARE TO BE READ IN CONJUNCTION WITH ANY
STRUCTURAL OR ENGINEERING DRAWINGS AND ASSOCIATED
TOWN PLANNING PERMITS AND DRAWINGS.
N3 SMOKE ALARMS TO BE INSTALLED IN ACCORDANCE WITH AS
3786 AND BE HARDWIRED WITH A BATTERY BACK-UP.
N4 ALL WET AREAS TO COMPLY WITH BCA 3.8.1 OR AS 3740 - WALL
FINISHEES SHALL BE IMPERVIOUS TO A HEIGHT OF 1800MM ABOVE
FLOOR LEVEL TO SHOWER ENCLOSURES AND 15MM ABOVE
BATHS, BASINS, SINKS AND TROUGHS IF WITHIN 75MM OF THE
WALL.
N5 CONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS, SETBACKS
AND SPECIFICATIONS PRIOR TO COMMENCING ANY WORKS OR
ORDERING MATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING
THAT ALL BUILDING WORKS CONFORM TO THE BCA, A.S CODES
CURRENT EDITIONS BUILDING REGULATIONS, LOCAL BY-LAWS AND
TOWN PLANNING REQUIREMENTS
N6 THE BUILDING SHALL BE PROTECTED IN ACCORDANCE WITH
AS3660.
N7 ALL DIMENSIONS MUST BE VERIFIED BEFORE THE
COMMENCEMENT OF ANY SITE WORKS OR DRAWINGS.. ENGINEERS
DRAWINGS MUST NOT BE SCALED. ALL DIMENSIONS NOTED ARE IN
MILLIMETERES UNLESS NOTED OTHERWISE
N8 ALL ELECTRICAL WORK TO COMPLY WITH AS 3008.1.1 – 2009 –
ELECTRICAL INSTALLATIONS – SELECTION OF CABLES AND AS
3012 – 2012 – ELECTRICAL
N9 ALL MECHANICAL VENTILATION REQUIREMENTS TO COMPLY WITH AS
1668.2 – 2012 – MECHANICAL VENTILATION
N10 ALL WINDOWS REQUIREMENTS AND INSTALLATION TO COMPLY
WITH AS 2047 – 1999 – WINDOWS IN BUILDINGS – SELECTION AND
INSTALLATION
N11 ALL GLAZING, INTERNAL AND EXTERNAL TO COMPLY WITH AS
1288 – 2006 – GLASS IN BUILDINGS – SELECTION AND INSTALLATION
AND HB 125 – THE GLASS AND GLAZING HANDBOOK
N12 ALL GLAZING IN THE BATHROOM, ENSUITE AND SHOWERS INCLUDING
SHOWER DOORS, BATH ENCLOSURES, UNSUPPORTED MIRRORS AND
WINDOWS) SHALL BE 'GRADE A' SAFTY GLAZING MATERIAL.
N13 THE RETAINING STRUCTURE IS TO COMPLY WITH AS 4678 – 2002 –
EARTH RETAINING STRUCTURES
N14 SOIL CLASSIFICATION: ADOPT CLASS M, REFER TO ENGINEERS REPORT
AND CONFIRM ON-SITE. ADOPT BAL RATING 29
N15 GUTTERS AND DOWNPIPES TO BE IN ACCORDANCE WITH AS 3500.3
STORM WATER DRAINAGE AND B.C.A CL3.5.2 AND CL3.1.2
N16 ALL CONCRETE SLABS TO COMPLY WITH B.C.A AND AS 2870
RESIDENTIAL SLABS AND FOOTINGS
N17 EXCAVATION OF TRENCHES FOR SEWERAGE, DRAINAGE ETC. TO BE
CARRIED OUT IN ACCORDANCE WITH CONTROLLING ATHORITIES
REQUIREMENTS.
N18 TOP SOIL AND VEGETATION UNDER SLAB TO BE REMOVED.
N19 ROOF SHEETING AND ROOF PENETRATIONS TO COMPLY WITH B.C.A.
CL
N20 ROOF AND WALLS MUST BE INSULATED AS PER B.C.A. 3.12.1.1
N21 ALL ELECTRICAL INSTALLATION TO CONFIRM TO AS 3000
N22 ALL MASONRY TO CONFORM WITH B.C.A CL 3.3.1 AND AS 3700
MASONRY.
N23 ALL TIMBER FRAME TO CONFORM TO AS 1684.4 AND THE TIMBER
FRAMING MANUAL.
N24 METAL LINTELS IN EXTERNAL WALLS TO BE HOT DIPPED
GALVANISED.
N25 WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZE WILL VARY
ACCORDING TO MANUFACTURERE,
N26 GLAZING TO CONFORM WITH AS1288 AND AS2047. GLAZING FLASHINGS
TO COMPLY WITH B.C.A. CL 3.5.3.6 AND AS 2904.
N27 STORM WATER DRAINS TO BE TAKEN TO THE LEGAL POINT OF
DISCHARGE AS DIRECTED BY THE LOCAL COUNCIL AND AND PLANS.
N28 EXCAVATION OF TRENCHES FOR SEWERAGE, DRAINAGE ETC, TO BE
CARRIED OUT IN ACCORDANCE WITH CONTROLLING AUTHORITIES
REQUIREMENTS.
SHEET LIST
FOREWORD
SOLE PROPRIETOR: MR AND MRS M METCALF OF 24 FINCH STREET
BEECHWORTH VIC 3747.
LOCAL GOVERNING COUNCIL: INDIGOE SHIRE COUNCIL
ARCHITECT: HALEN T MOKA
FOR ANY FURTHER INFORMATION CONTACT HALEN T MOKA HERE:
PH: 0410 522 743 OR HALENMOKA@GMAIL.COM
THIS DOCUMENT HAS BEEN PROVIDED BY HALEN MOKA OF FORTITUDE - DESIGN AND BUILD, ON BEHALF OF MR AND MRS M
METCALF, IN CONJUNCTION WITH ENGINEERS SPECIFICATIONS AND DRAWINGS AT THE REQUEST OF THE BUILDING PERMIT
APPLICATION PROCEDURES OF THE INDIGOE SHIRE COUNCIL. THIS DOCUMENT MUST BE ASSESSED AND CONSIDERED AS A
COMPONENT IN A SERIES OF REQUESTED DOCUMENTS FOR THE APPLICATION OF A BUILDING PERMIT FOR THE RESIDENTIAL
DEVELOPMENT AT 24 FINCH STREET BEECHWORTH, VIC, 3747.
FORTITUDE TAKES NO RESPONSIBILITY FOR ANY DAMAGES TO ANY INDIVIDUALS HEALTH OF FINANCIAL DAMAGES THAT MAY
OCCUR TO ANY THIRD PARTY ASSOCIATIONS WHEN USING THESE CONSTRUCTION DRAWINGS AS A GUIDE IN ANY PROJECT.
MR AND MRS M METCALF
24 FINCH STREET BEECHWORTH 3747
DEMOLITION OF EXISTING DWELLING AND
CONSTRUCTION OF PROPOSED SINGLE
STORY DWELLING WITH ATTATCHED
GARAGE.
CLIENT:
ADDRESS:
PROJECT:
Scale Checked by
Drawn by
Date Project number
1 : 100
Schedules
P1.0
FINCH STREET NEW DWELLING
MR A AND MRS M METCALF Issue Date
Author
HALEN MOKA
24 FINCH STREET, BEECHWORTH VIC W01
Door Schedule
Level Mark Location Height Width Thickness Finish
Frame
Material Comments
Ground Floor 1 MASTER 2134 915 51 NATURAL
WHITE
CEDAR SWINGING
Ground Floor 2 BATHROOM 2134 813 51 NATURAL
WHITE
CEDAR SWINGING
Ground Floor 3 LAUNDRY 2134 915 51 NATURAL
WHITE
CEDAR SWINGING
Ground Floor 4 BED 1 2134 915 51 NATURAL
WHITE
CEDAR SWINGING
Ground Floor 5 BED 2 2134 915 51 NATURAL
WHITE
CEDAR SWINGING
Ground Floor 6 BED 2 2032 1230 51 NATURAL
WHITE
CEDAR DOUBLE SWINGING
Ground Floor 7 BED 1 2032 1230 51 NATURAL
WHITE
CEDAR DOUBLE SWINGING
Ground Floor 8 GARAGE 2134 813 51 NATURAL
WHITE
TURPENTINE SWINGING W/NON-COMBUSTIBLE
WEATHER STRIP
Ground Floor 9 STORAGE 2032 762 51 NATURAL
WHITE
CEDAR SWINGING
Ground Floor 10 STUDY 2134 915 51 NATURAL
WHITE
CEDAR SWINGING
Ground Floor 11 LAUNDRY 2134 915 51 NATURAL
WHITE
CEDAR SWINGING
Ground Floor 12 MASTER 2438 3658 250 DOUBLE
BASS
TURPENTINE DOUBLE SLIDING
Ground Floor 13 BED 1 2432 1730 120 DOUBLE
BASS
TURPENTINE SINGLE SLIDING
Ground Floor 14 FRONT DOOR 2040 820 51 DOUBLE
BASS
TURPENTINE SWINGING W/NON-COMBUSTIBLE
WEATHER STRIP
Ground Floor 15 BED 2 2432 1730 120 DOUBLE
BASS
TURPENTINE SINGLE SLIDING W/NON-COMBUSTIBLE
WEATHER STRIP
Ground Floor 16 LAUNDRY 2432 1730 120 DOUBLE
BASS
TURPENTINE SINGLE SLIDING W/NON-COMBUSTIBLE
WEATHER STRIP
Ground Floor 17 LIVING 2438 3658 250 DOUBLE
BASS
TURPENTINE DOUBLE SLIDING NON-COMBUSTIBLE
WEATHER STRIP
Ground Floor 18 HALL 2438 6658 300 DOUBLE
BASS
TURPENTINE 4 PANEL SLIDING NON-COMBUSTIBLE
WEATHER STRIP
Ground Floor 19 DINING 2550 3900 80 DOUBLE
BASS
TURPENTINE DOUBLE SLIDING NON-COMBUSTIBLE
WEATHER STRIP
Ground Floor 20 HALL 2982 1430 50 DOUBLE
BASS
TURPENTINE GLASS SWINGING 9MM TOUGHENED
GLASS W/NON-COMBUSTIBLE WEATHER
STRIP
Ground Floor: 20
Grand total: 20
Window Schedule
Mark Location Window Style Width Height Material Glazing Remarks
1 PANTRY FIXED 406 1830 TURPENTINE SINGLE 9MM TOUGHENED
FROSTED GLASS
ARGON FILLED AND THERMALLY
BROKEN
2 BATHROOM AWNING 915 1220 ALUMINIUM 9MM TOUGHEND GLASS DBL
GLAZED
ARGON FILLED AND THERMALLY
BROKEN
3 ENSUITE AWNING 3339 458 ALUMINIUM 9MM TOUGHEND GLASS DBL
GLAZED
ARGON FILLED AND THERMALLY
BROKEN
4 KITCHEN AWNING 610 1220 ALUMINIUM 9MM TOUGHEND GLASS DBL
GLAZED
ARGON FILLED AND THERMALLY
BROKEN
5 STUDY AWNING 610 1830 ALUMINIUM 9MM TOUGHEND GLASS DBL
GLAZED
ARGON FILLED AND THERMALLY
BROKEN
6 STUDY AWNING 610 1830 ALUMINIUM 9MM TOUGHEND GLASS DBL
GLAZED
ARGON FILLED AND THERMALLY
BROKEN
7 BED 2 AWNING 1400 1200 ALUMINIUM 9MM TOUGHEND GLASS DBL
GLAZED
ARGON FILLED AND THERMALLY
BROKEN
8 KITCHEN AWNING 610 1220 ALUMINIUM 9MM TOUGHEND GLASS DBL
GLAZED
ARGON FILLED AND THERMALLY
BROKEN
9 KITCHEN AWNING 610 1220 ALUMINIUM 9MM TOUGHEND GLASS DBL
GLAZED
ARGON FILLED AND THERMALLY
BROKEN
Sheet List
Sheet Number Sheet Name
W01 Schedules
W02 Site Plan
W03 Landscaping Plan
W04 Site Drainage Plan
W05 Roof Plan
W06 East/West Elevations
W07 North/ South Elevations
W08 Sections
W09 Sections II
W10 Electrical Plan
W11 Reflected Ceiling Plan
W12 Floor Plan
W13 Slab Plan
W14 Internal Elevations
W15 Internal Elevations II
W16 Details
W17 Details II
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
1000
1940
1195
13170
50180
14800
3500
N
O
RTH
5170
0
0
51750
0
518
0
0
0
5190
0
0
PROPOSED CONCRETE
DRIVEWAY MACHINED FINISH
IN-GROUND
POOL
EXISTING UNSEALED
DRIVEWAY
CONCRETE FOOTPATH
EXISTING CONCRETE
CROSSOVER
PROPOSED CONCRETE
CROSSOVER
CONCRETEFOOTPATH
CONCRETEFOOTPATH
DECKING
PP
48°00'00''
48°00'00''
42°00'00''
42°00'00''
EXISTING SINGLE STORY DWELLING
TO BE COMPLETELY DEMOLISHED
EXISTINGFENCINGTO
BEREMOVED
WM
2426
GATE
TWO STOREY DWELLING
LIGHT WEIGHT CONSTRUCTION
W/ HIGH PITCHED GABLE ROOF.
ATTATCHED MULTIPLE
GABLE ROOF SINGLE
STOREY EXTENSIONS
SW SWSWSWSW
SWSW
SW
SW
SW SW SW SW SW SW
1000
SW SW SW SW
SW SW
SWSW
S S S S S S S
S
S
S
S
S
W W W W W W W WW
S
STORMWATER PIPES
TO CONNECT TO LPD
PROPOSED SINGLE
STORY DWELLING
DECKING
POOL GATE TO OPEN
AWAY FROM POOL WITH
SELF CLOSING SAFETY LATCH
1500MM HIGH MIN.
HABITABLE WINDOWS
1246
GATE
GRASS LAWN
ECO OUTDOOR DRYSTONE PAVERS
INSTALLED TO MAUNFS SPECS
DP DP
DP
DPDPDP
DP
DP
DP
Site Notes
DEMOLITION NOTES: EXISTING SINGLE DWELLING AND EXISTING FENCING ON SITE TO BE DEMOLISHED IN ACCORDANCE WITH AS 2601 THE
DEMOLITION OF STRUCTURES AND VICTORIAS CODE OF PRACTICE FOR DEMOLITION. TECHNIQUES FOR THE PREVENTION OF DUST, WATER-
RUN OFF AND ANY MATERIALS FROM DAMAGING THE AMENITY OF THE SURROUNDING AREA MUST BE IMPLEMENTED. THE LARGE ELM
TREE TO BE RETAINED MUST BE PROTECTED DURING DEMOLITION AND CONSTRUCTION.
SEWERAGE NOTIES: SEWERAGE PIPES ARE U-PVC DN150 WITH A 1:100 FALL IN ACCORDANCE WITH AS 3500.2 SANITARY PLUMBING AND
DRAINAGE SYSTEMS. A DN150 INSPECTION SHAFT MUST BE INSTALLED AS CLOSE TO THE SEWER CONNECTION AS POSSIBLE. CLEAR OF
ALL EASEMENTS AND IN THE OPEN AS TO BE ACCESSIBLE. tHEY MUST TERMINATE AT OR NEAR GROUND LEVEL WITH A REMOVABLE
AIRTIGHT DN150 INSPECTION CAP.
STORM WATER NOTES: PIPES TO BE MADE OF U-PVC DN150 PIPE AT 1:100 FALL.. MUST BE A 300MM SEPERATION BETWEEN ANY
UNDERGROUND WATER SERVICE PIPE, GAS PIPE AND/OR ELECTRICAL SUPPLY CABLES.
ELECTRICTY CABLES NOTES: MUST BE INDICATED ALONG ITS LENGTH WITH ORANGE MARKER TAPE 150MM ABOVE THE INSTALLED
PIPE. MUST BE BACKFILLED APPROPRIATELY COMPLYING WITH AS/NZS 2681.1, AS/NZS 3500.5 AND AS/NZS 3500.3.
THE PROPOSED CONSTRUCTION DOES NOT REQUIRE THE NEED FOR EARTH FILL AS THE CONCRETE SLAB STEPS UP THE SLOPE OF THE
LAND. A CUT WILL BE MADE NEAR THE SOUTHERN END OF THE PROPERTY AND 900MM TIMBER RETAINING WALL WILL BE CONSTRUCTED
AS SHOWN ON THE PLAN AND W15 RETAINING WALL DETAIL.
LEGEND
SEWERAGE
STORM WATER
DOWNPIPE
POWER LINES
PROPOSED UNDERGROUND POWER CABLE
POWERPOLE
PROPOSED UNDERGROUND WATER PIPE
WATER MAIN
PROPOSED GATE
PROPOSED 2M PRIVACY FENCE
W/400MM PRIVACY LATTICE
EXISTING 2M METER FENCE
SITE CUT AREA
900MM RETAINING WALL
PP
WM
General Notes
SITE AREA: 650M
BUILDING AREA: 307M
BUILDING AREA PERCENTAGE: 47%
WIND ZONE: N1
SOIL CLASSIFICATION: M
BAL RATING: BAL 12.5
EXISTING BUILDING TO
BE DEMOLISHED
TREES TO BE REMOVED
TREE TO BE KEPT
CONTOUR LINES
W
P
P
SW
S
DP
Scale Checked by
Drawn by
Date Project number
1 : 100
Site Plan
P1.0
FINCH STREET NEW DWELLING
MR A AND MRS M METCALF Issue Date
Author
HALEN MOKA
24 FINCH STREET, BEECHWORTH VIC W02
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
N
O
RTH
5170
0
0
51750
0
518
0
0
0
5190
0
0
PROPOSED CONCRETE
DRIVEWAY MACHINED FINISH
IN-GROUND
POOL
PORCH
EXISTINGFENCINGTO
BEREMOVED
RETAININGWALL
Scale Checked by
Drawn by
Date Project number
1 : 100
Landscaping Plan
P1.0
FINCH STREET NEW DWELLING
MR A AND MRS M METCALF Issue Date
Author
Checker
24 FINCH STREET, BEECHWORTH VIC W03
SITE AREA: 650M
BUILDING AREA: 307M
BUILDING AREA PERCENTAGE: 47%
WIND ZONE: N1
SOIL CLASSIFICATION: M
TREE TO BE PLANTED
SMALL GRASS PLANT
TREES TO BE REMOVED
ELM TREE TO BE KEPT AND PROTECTED
site notes
LARGE ELM TREE IN THE CENTRE OF THE PROPERTY TO BE KEPT AND PROTECTED DURING
CONSTRUCTION IN ACCORDANCE WITH AS 4970 PROTECTION OF TREES ON DEVELOPMENTS.
TREE PROTECTION ZONE TO BE 4200MM. LARGE ELM TREES ALONG THE NATURE STRIP ARE TO
BE PROTECTED AND FENCED TO ENSURE NO DAMAGE OCCURS.
ALL GARDEN BEDS TO BE COVERED EVENLY IN TOPSOIL AND DARK RED CORSE BARK.
TREES TO BE REMOVED HAVE BEEN DEEMED UNSAFE TO OCCUPANTS AND NEIGHBORS BY
A CERTIFIED ARBORIST AND THUS MUST BE REMOVED APPROPRIATELY. TREES MUST BE
REMOVED BEFORE DEMOLITION WORKS BEGIN.
PAVERS ARE TO BE TRAVERTINE CAPRI PAVERS FROM ECO-OUTDOOR. PAVERS ARE TO BE
SEMI-SUBMERGED BELOW THE EARTH ON A 50MM BED OF SAND AS TO PREVENT MOVEMENT
AND ENSURE A SECURE POSITION.
general notes
legend
DILLWYNIA CINERASCENS
GREY PARROT-PEA
GREVILLEA APLINA
CATS CLAW GREVILLEA
ACACIA ACINACEA
GOLD DUST WATTLE
JOYCEA PALLIIDA
SILVERTOP WALLABY-GRASS
XANTHORRHOEA PREISSII
WESTERN AUSTRALIAN GRASSTREE
vegetation name type no.
TREE TO BE PLANTED
SHRUB 20CM TO 1M 40
MEDIUM SHRUB 1M TO 5M 20
LARGE GRASS LIKE PLANT 6
>1M
MEDIUM GRASS TREE .UP TO 5M 2
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
N
O
RTH
5170
0
0
51750
0
518
0
0
0
5190
0
0
PROPOSED CONCRETE
DRIVEWAY MACHINED FINISH
IN-GROUND
POOL
PORCH
EXISTINGFENCINGTO
BEREMOVED
SITE NOTES
IMPERMEABLE AREA: 267M
SITE AREA: 650M
PERMEABLE AREA PERCENTAGE: 38%
SOIL CLASSIFICATION: M
general NOTES
ALL SOIL MUST SLOPE AWAY FROM BUILDING FOR A MINIMUM OF 1M.
AGGREGATION PIPE TO BE VINIDEX 100MM X 20M SLOTTED DRAINCOIL AND
INSTALLED BELOW AND BEHIND THE RETAINING WALL ABOVE GEO FABRIC AND
COVERED IN CORSE GRANULAR FILL. GEO FABRIC MUST BE USED TO
SEPERATE THE GRANULAR FILL AND SOIL BEHIND THE RETAINING WALL.
A 0.2 POLYETHYLENE VAPOUR BARRIER MUST BE USED TO DIRECT WATER
BUILDUP TO THE AGGREGATION PIPE AND PREVENT WATER FROM
TRANSFERRING THROUGH THE WALL SEE RETAINING WALL DETAIL ON W15.
ANY PLUMBING WORKS CARRIED OUT THAT DOES NOT COMPLY WITH THE
RELEVANT PLUMBING REGULATIONS AND CONTRACT DOCUMENTS WILL BE
CONSIDERED DEFECTIVE.
CONSTRUCTION TOLERANCES INCLUDE 19MM FOR LEVEL GUTTERS AND 13MM
FOR SLOPING GUTTERS. THIS MUST BE ADHEARED TO. GUTTERS SHALL NOT
RETAIN MORE THAN 10MM OF WATER. LEAKS ARE CONSIDERED A DEFECT. PVC
PIPES SHALL HAVE A MEAN OUTSIDE DIAMETER OF 110 AND 100.4MM, A MEAN
INTERNAL DIAMETER OF 98MM AND A MAXIMM OUT OF SQUARENESS OF 4MM.
RETAININGWALL
SW SW SW SW
SW
SW
SW SW SW
SW SW SW SW SW SW SW SW
SWSW
SW
SWSW
DP
DP
DP
DP
DP DP DP
DP
DP
ROOF PITCH
7 DEGREES
ROOF PITCH
35 DEGREES
ROOF PITCH
35 DEGREES
ROOF PITCH
7 DEGREES
RAIN GARDEN COLLECTS WATER RUNOFF FROM DRIVEWAY
WATER RUNOFF TO DRAIN NATURALLY THROUGH
GRASS LAWN AND SURROUNDING RAIN GARDENS
RAIN GARDEN COLLECTS EXCESS WATER RUNOFF FROM GRASS LAWN
RAIN GARDEN COLLECTS EXCESS WATER RUNOFF AND DRAINS IN
VINIDEX 100MM X 20M SLOTTED DRAINCOIL TO STORM WATER PIPES
LAND SLOPES AWAY FROM HOUSE FOR 1 A MINIMUM OF 1M. WATER RUNOFF DRAINS
TO VINIDEX 100MM X 20M SLOTTED DRAINCOIL UNDERNEATH RETAINING WALL
STORM WATER SYSTEM SPECIFICATIONS:
DOWNPIPES TO BE DN 100 TYPE C U-PVC DOWNPIPE LOW GLOSS FINISH W/
200mm X 200mm METAL RAINWATER HEAD FIXED TO CLADDING USING
MANUFACTURERS SPEC.
GUTTERS TO BE 90MM COLOURBOND LYSAGHT QUAD GUTTER PAINTED
'MONUMENT' COLOUR. FIXED TO MANUFACTURERES SPECS.
STORM WATER PIPES TO BE MADE OF U-PVC DN150 PIPE AT 1:100 FALL..
MUST BE A 300MM SEPERATION BETWEEN ANY UNDERGROUND WATER
SERVICE PIPE, GAS PIPE AND/OR ELECTRICAL SUPPLY CABLES.
STORM WATER PIPES TO FLOW DOWN HILL AND CONNECT TO LEGAL POINT
OF DISCHARGE AT THE FRONT OF THE PROPERTY.
LEGEND
STORM WATER PIPE
AGGREGATION PIPE
FALL DIRECTION INDICATOR
CONTOUR LINES
UNDERGROUND PIPES LOCATED EXTERNALLY FROM THE BUILDING SHALL BE IN
A 2M DEEP TRENCH BY 0.3M WIDE. THE PIPES SHALL BE LAID ON A BED OF
MINIMUM 75MM OF CRUSHED ROCK OR GRAVEL UP TO A MAXIMUM SIZE OF
14MM.
THERE MUST BE A MINIMUM OF 100MM BETWEEN THE PIPE AND THE SIDES OF
THE TRENCH.
SCREENED CRUSHED ROCK SIZES 3MM TO 20MM TO BE USED AS THE
GRANULAR FILL FILTER MATERIAL FOR AGGREGATION PIPES.
PIPES MUST DISCHARGE TO TO THE LEGAL POINT OF DISCHARGE. THE
LOCATION OF THE LEGAL POINT OF DISCHARGE WILL BE DETERMINED BY THE
AUTHORITY HAVING JURISDICTION. THE CONNECTION WILL BE LOCATED OUTSIDE
THE PROPERTY AND CONNECT TO AN ELEMENT OF THE EXTERNAL STORM
WATER DRAINAGE NETWORK AND MAINS PIPES.
Scale Checked by
Drawn by
Date Project number
1 : 100
Site Drainage Plan
P1.0
FINCH STREET NEW DWELLING
MR A AND MRS M METCALF Issue Date
Author
HALEN MOKA
24 FINCH STREET, BEECHWORTH VIC W04
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
DECKING
DN 100 TYPE C U-PVC
DOWNPIPE LOW GLOSS FINISH
200mm X 200mm METAL RAINWATER HEAD
RWH
200X200 METAL RAIN WATER
HEAD COLORBOND LOW GLOSS
FINISH MONUMENT COLOUR
RWH
DP
DPDP
DP
INDICTIVE POSITION OF 2500L RHEEM
PREMIER® HILINE SOLAR HOT WATER
HEATER GAS BOOSTED.
MODEL: 52H180K/1S-G
INSTALLED TO MANUFACTURERES
SPECIFICATIONS
INDICTIVE POSITION OF PREMIUM LINE
GERMAN SOLAR, SOLAR PANELS
INSTALLED TO MANUFACTURERES
SPECIFICATIONS
90MM METAL COLOURBOND LYSAGHT
QUAD GUTTER 'MONUMENT'
FIXED TO MANUFACTURERES SPECS
3 DEGREE FALL
ROOF PITCH
35 DEGREES
ROOF PITCH
35 DEGREES
EXHAUST FAN INSTALLED TO
MANUFACTUERES SPECIFICATIONS
SEALED WITH A NON-COMBUSTIBLE
SEALANT.
620X150 VELUX OPENABLE ROOF WINDOWS
INSTALLED TO MANUFACTURERES SPECIFICATIONS
620X150 VELUX OPENABLE ROOF WINDOWS
POOL
RANGEHOOD EXHAUST FAN INSTALLED TO
MANUFACTUREERS SPECIFICATIONS
150X150 STEEL COLOURBOND RIDGE
CAPPING 'MONUMENT' COLOUR.
0.42 BMT WITH A RECESSED CUT TO
MATCH COLOURBOND TRIMDEK
PROFILE.
FLOW DIRECTION INDICATOR
DP
6MM ALUCOBOND SHEETING WITH A 5MM
DEEP BY 10MM WIDE ROUTE LINE
AT 900 CENTRES. LOW GLOSS
SOLID ANTHRAZIT GREY- 105 COLOUR SEALED
WITH BLACK WATERPROOF EXTERIOR
SEALANT. ALUCOBOND MUST BE 70% NON-
COMBUSTIBLE OR MORE AND COMPLY WITH
AS 1530.3. GROUP 1 RATING WHEN TESTED TO
ISO 9705.
ROOF PITCH
7 DEGREES
ROOF PITCH
7 DEGREES
ULTRA RANGE TRIMDEK COLORBOND
SHEETING MONUMENT COLOUR
3 DEGREE FALL
6MM ALUCOBOND SHEETING WITH A 5MM
DEEP BY 10MM WIDE ROUTE LINE
AT 900 CENTRES. LOW GLOSS
SOLID ANTHRAZIT GREY- 105 COLOUR
ALUCOBOND MUST BE 70% NON-
COMBUSTIBLE OR MORE AND COMPLY WITH
AS 1530.3. GROUP 1 RATING WHEN TESTED TO
ISO 9705.
620X150 VELUX OPENABLE
ROOF WINDOWS INSTALLED TO
MANUFACTURERES SPECIFICATIONS
GLAZING AND SEALANTS AND FLASHINGS
TO COMPLY WITH AS 3959.
FASCIA COLOURBOND STRAMIT METAL
MONMUMENT COLOUR
FASCIA COLOURBOND STRAMIT METAL
MONMUMENT COLOUR
FASCIA COLOURBOND STRAMIT METAL
MONMUMENT COLOUR
HOT WATER SYSTEM NOTES: HWS TO BE RHEEM PREMIER® HILINE SOLAR HOT WATER HEATER GAS BOOSTED.
MODEL: 52H180K/1S-G
SOLAR COLLECTORS: S200 X2
BOOSTER TYPE GAS: REMOTE GAS 27L/MIN
HOT WATER HEATER MUST BE INSTALLED IN ACCORDANCE WITH AS3500.4 HEATED WATER SERVICE AND AS3500.5
DOMESTIC INSTALLATIONS.
SOLAR PANELS TO BE FIXED ON TOP OF ROOF AND COLLECTORS SHOULD BE INCLINED AT A SIMILAR ANGLE TO
THE LATITUDE ANGLE AND SHOULD BE LOCATED AS TO BE CLEAR OF SHADE FOR 3 HOURS EITHER SIDE OF
SOLAR NOON. THE DEVIATION FROM THIS ANGLE SHOULD BE NOT GREATER THAN ±20° AS PER MANUFACTURERS
SPECIFICATIONS AND AS 3500.4 HEATED WATER SERVICES.
THE HOT WATER SYSTEM IS TO BE INSTALLED ABOVE THE STUDY ON THE ROOF. IT MUST BE EASILY ACCESSIBLE
TO RELIEF VALVES AND BE EASILY REMOVABLE WITHOUT MAJOR STRUCTURAL ALTERATIONS TO THE BUILDING
OR PIPEWORK.
HOT WATER SYSTEM MUST BE CONNECTED TO THE 10 HOT WATER OUTLETS THROUGHOUT THE BUILDING.
CONSIDERATION SHALL BE GIVEN TO THE ROUTE TAKEN BY VENT PIPES, DRAIN LINES OR SAFE WASTES.
General Notes
GUTTER FLOW DIRECTION
GUTTER FLOW DIRECTION CHANGE
DOWNPIPE
EXHAUST FAN
RAINWATER HEAD
SKYLIGHT
LEGEND
DP
RWH
DP
FLASHINGS TO BE INSTALLED TO MANUFACTURERES
SPECIFICATIONS.
DOWNPIPES MUST NOT HAVE MORE THAN 50 SQUARE
METERS OF ROOFING SURFACE ALLOCATED TO ANY
SINGLE DOWNPIPE.
DOWNPIPES ARE 100 MM DIA METAL PIPE. REF: BCA
3.5.2.5 FOR INSTALLATION.
DRAINAGE OF STORMWATER MUST BE DRAINED
CORRECTLY AND IN ACCORDANCE WITH AS3500.4
3 SOLAR PANELS TO BE INSTALLED ON THE EASTERN
MOST POINT OF THE ROOF. REFER TO
MAUFACTURERES SPECIFICATIONS FOR INSTALLATION.
ANY VENTS AND ALL MECHANICAL VENILATION TO BE
SEALED AND MUST COMPLY WITH AS1668.2
ROOF TO BE SARKED AND OVER LAPPED 200MM
WHERE NEW SHEETS JOIN HORIZONTALLY. SARKING
MUST DRAIN INTO GUTTER.
RAINWATER HEAD INSTALLED TO MANUFACTURERES
SPECS.
COLOURBOND ROOFING SPECIFICATIONS:
MATERIAL: COLORBOND® STEEL CONFORMING TO AS
1397-G550-AM100 AND AS 2728.
COLOUR: MONUMENT®
THICKNESS: 0.42 BMT
FIXING METHOD: FASTENERS SHOULD BE SELECTED TO
MATCH THE GRADE OF THE ROOFING MATERIAL.
SIZE: AS PER ROOF SIZE.
SPACING: 1200MM
PROFILE: TRIMDEK
ROOF CONTRACTOR: THE ROOF SHEETING, WALLING
AND ACCESSORIES SHALL BE INSTALLED IN
ACCORDANCE WITH MANUFACTURER SPECIFICATIONS.
VELUX ROOF WINDOWS SPECIFICATIONS:
VELUX ROOF WINDOWS AND MATERIALS THAT IT
CONSISTS OF TO MEET THE REQUIREMENTS OF AS4285
SKYLIGHTS, AS1288 OVERHEAD GLAZING AND AS3959
BUSHFIRE FOR BAL 40 REQUIREMENTS AND AS1530.1
NON-COMBUSTIBILITY.. MUST BE INSTALLED TO
MANUFACTURERES SPECIFICATIONS AND SEALED
APPROPRIATELY TO ENSURE THERE IS NO WATER
INGRESS.
ALUCOBOND® PLUS SPECIFICATIONS:
ALUCOBOND® PLUS ALUMINIUM COMPOSITE MATERIAL
(ACM) SHALL BE 6MM THICK AND CONSIST OF 2
LAYERS OF 0.5MM THICK ALUMINIUM SANDWICHING A
MINERAL FILLED FIRE RESISTANT CORE CONTAINING 70%
NON COMBUSTIBLE MINERAL FILLING.
THE ALUMINIUM SKINS SHALL BE OF ALLOY ALMG 1- NS41
(EN AW 5005A NEAREST EQUIVALENT) HAVING AN
ULTIMATE STRENGTH OF 130 MPA AND 0.2% PROOF
STRESS OF 90 MPA. ALUCOBOND SHEETING MUST BE
FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT
BRADERS EVERY 100MM AROUND THE EDGES TO
TIMBER BATTENS AND STUDS. BE SURE TO FIX EXTRA
TIMBER PEICES AROUND ALUCOBOND EDGES WHERE
THERE ARE GAPS AND NO TIMBER TO FIX TO.
MUST COMPLY WITH THE REQUIREMENTS OF BAL 12.5 IN
AS 3959 .
PITCH CHANGE FLASHING
STEEL FLASHING MUST BE USED WHERE ROOF PITCHES
CHANGE AND MUST EXTEND UNDERNEATH THE UPPER
ROOF WITH A 20MM RETURN FOLD, AND THEN OVER
THE TOP OF THE LOWER ROOF WITH A BREAK TO SUIT
THE ROOFING PROFILE (CORRUGATED IRON). TO MINIMISE
THE PROBLEM OF WIND DRIVING WATER UP-HILL THE
TOP ENDS OF THE LOWER ROOF SHOULD BE TURNED
UP.
THE END OF THE FLASHING THAT SITS ABOVE THE
LOWER ROOF AND OVERLAPS BY 150MM, MUST HAVE A
NOTCHED BREAK TO ALLOW THE ROOF PROFILE TO
BE FITTED INTO THE FLASHING TO GIVE GREATER
PROTECTION FROM WATER BLOWING BACK UNDER THE
FLASHING. SEE W16 ROOF PITCH CHANGE
LONGITUDINAL FLASHINGS SHALL 0.42BMT STEEL
AND BE FASTENED AT MAXIMUM 500MM CENTRES.
LONGITUDINAL FLASHINGS SHALL 0.42BMT
STEEL AND BE FASTENED AT MAXIMUM
500MM CENTRES
LONGITUDINAL 0.42BMT STEEL FLASHINGS MUST BE
FASTENED AT MAXIMUM 500MM CENTRES.
6MM ALUCOBOND SHEETING WITH A 5MM DEEP BY 10MM WIDE ROUTE LINE
AT 900 CENTRES. LOW GLOSS
SOLID ANTHRAZIT GREY- 105 COLOUR
ALUCOBOND MUST BE 70% NON-COMBUSTIBLE OR MORE AND COMPLY WITH AS 1530.3.
GROUP 1 RATING WHEN TESTED TO ISO 9705.
90MM METAL COLOURBOND LYSAGHT
QUAD GUTTER 'MONUMENT'
FIXED TO MANUFACTURERES SPECS
3 DEGREE FALL
90MM METAL COLOURBOND LYSAGHT
QUAD GUTTER 'MONUMENT'
FIXED TO MANUFACTURERES SPECS
3 DEGREE FALL
Scale Checked by
Drawn by
Date Project number
1 : 100
Roof Plan
P1.0
FINCH STREET NEW DWELLING
MR A AND MRS M METCALF Issue Date
Author
HALEN MOKA
24 FINCH STREET, BEECHWORTH VIC W05
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
350
738
1691
1
W09
3421
121315 16 2
3
45 6
7
8 9
ECO OUT DOOR DRYSTONE WALL"ALPINE"
INSTALLED TO MANUFACTURERES SPECS
100X25 TURPENTINE
DECKING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED
WITH 50MM
GAL SELF DRILLING
SCREWS
100X25 TURPENTINE
CLADDING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED
WITH 50MM
GAL CLOUTS
ALUCOBOND SPARKLING BLACK
METALLIC 888 SEALED WITH BLACK SILICONE
FIXED WITH B20620 IMPULSE C15
BFP STRAIGHT BRADERS
ALUCOBOND
SPARKLING
BLACK
METALLIC 888
SEALED WITH
BLACK
SILICONE
FIXED WITH
B20620
IMPULSE C15
BFP STRAIGHT
BRADERS
DN 100 TYPE C METAL DOWNPIPE 'MONUMENT'
LOW GLOSS FINISH
220mm X 140mm
METAL RAINWATER HEAD FIXED TO CLADDING
USING MANUFACTURERS SPECS
DN 100 TYPE C METAL
DOWNPIPE 'MONUMENT'
LOW GLOSS FINISH
220mm X 140mm
METAL RAINWATER HEAD
FIXED TO CLADDING USING
MANUFACTURERS SPECS
INDICTIVE POSITION OF PREMIUM LINE GERMAN
SOLAR, SOLAR PANELS
INSTALLED TO MANUFACTURERES
SPECIFICATIONS
100X25 TURPENTINE DECKING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED WITH 50MM
GAL SELF DRILLING SCREWS
.
COLOURBOND CORRGATED
ROOFING IRON
INSTALLED TO MANUFCTURERES SPECS
'MONUMENT'
ECO OUT DOOR DRYSTONE PAVERS
"ALPINE"
INSTALLED TO MANUFACTURERES SPECS
COLOURBON IRON RIDGE CAPPING
FIXED TO MANUYFACTURERES SPECIFICATIONS
'MONUMENT'
RETAINING
WALL SEE
DETAIL
HIGHGROVE 9MM TOUGHENED SAFETY
GLASS 1200X1300X12 PANEL
STAINLESS STEEL FIXING TO
MANUFACTURERES SPECIFICATIONS
INDICTIVE POSITION OF
PHOTOVOLTAICS FOR SOLAR
HOT WATER SYSTEM
INSTALLED TO
MANUFACTURERES
SPECIFICATIONS
90MM METAL COLOURBOND LYSAGHT
QUAD GUTTER 'MONUMENT'
FIXED TO MANUFACTURERES SPECS
INDICTIVE POSITION OF 2500L RHEEM PREMIER® HILINE
SOLAR HOT WATER HEATER GAS BOOSTED.
MODEL: 52H180K/1S-G
INSTALLED TO MANUFACTURERES SPECIFICATIONS
SKYDOME LOW E DOUBLE GLAZED
BLACK ALUMINIUM FRAME INSTALLED
TO MANUFACTURERES SPECS
180 STEP
DOWN ON
DECKING.
5960
NATURAL
GROUND LEVEL
1788
1050
600
688
1
W09
ALUCOBOND SPARKLING BLACK
METALLIC 888 SEALED WITH BLACK SILICONE
FIXED WITH B20620 IMPULSE C15
BFP STRAIGHT BRADERS
SKYDOME LOW E DOUBLE GLAZED
BLACK ALUMINIUM FRAME INSTALLED
TO MANUFACTURERES SPECS
COLOURBOND CORRGATED
ROOFING IRON
INSTALLED TO MANUFCTURERES SPECS
'MONUMENT'
100X25 TURPENTINE CLADDING
INTERGRAIN REDWOOD STAIN
FIXED WITH B20620 IMPULSE C15
BFP STRAIGHT BRADERS
ECO OUT DOOR DRYSTONE WALL"ALPINE"
INSTALLED TO MANUFACTURERES SPECS
DN 100 TYPE C METAL DOWNPIPE
'MONUMENT' LOW GLOSS FINISH
220mm X 140mm
METAL RAINWATER HEAD FIXED TO
CLADDING USING MANUFACTURERS
SPECS
DN 100 TYPE C METAL DOWNPIPE
'MONUMENT'
LOW GLOSS FINISH
220mm X 140mm
METAL RAINWATER HEAD FIXED TO
CLADDING USING MANUFACTURERS SPECS
DN 100 TYPE C METAL
DOWNPIPE 'MONUMENT' LOW
GLOSS FINISH
220mm X 140mm
METAL RAINWATER HEAD
FIXED TO CLADDING USING
MANUFACTURERS SPECS
ALUCOBOND SPARKLING
BLACK
METALLIC 888 SEALED
WITH BLACK SILICONE
FIXED WITH B20620
IMPULSE C15
BFP STRAIGHT BRADERS
ALUCOBOND SPARKLING
BLACK
METALLIC 888 SEALED
WITH BLACK SILICONE
FIXED WITH B20620
IMPULSE C15
BFP STRAIGHT BRADERS
17 18 2090MM COLOURBOND LYSAGHT
QUAD GUTTER 'MONUMENT'
FIXED TO MANUFACTURERES SPECS
90MM COLOURBOND LYSAGHT
QUAD GUTTER 'MONUMENT'
FIXED TO MANUFACTURERES SPECS
STAINLESSSTEEL POOL LADDER
INSTALLED TO MANUFACTURERES
SPECIFICATIONS
ECO OUT DOOR
DRYSTONE
WALL"ALPINE"
INSTALLED TO
MANUFACTURERES
SPECS
COLOURBON IRON RIDGE CAPPING
FIXED TO MANUYFACTURERES SPECIFICATIONS
'MONUMENT'
100X25 TURPENTINE
DECKING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED
WITH 50MM
GAL SELF DRILLING
SCREWS
100X25 TURPENTINE CLADDING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED WITH 50MM
GAL CLOUTS
COLOURBOND CORRGATED
ROOFING IRON
INSTALLED TO MANUFCTURERES
SPECS 'MONUMENT'
SKYLIGHTS TO BE INSTALLED TO MANUFACTURERES SPECIFICIATIONS
AND SEALED TO PREVANT WATER INGRES
ALL STORMWATER GUTTERS, PIPES AND SERVICES TO BE CONSTRUCTED IN
ACCORDANCE WITH ASNZS 3500.3 PASRT 3 STORMWATER DRAINAGE
.
FEATURE WALL AND STONE WALL AT THE FRONT OF THE PROPERTY AND
ATTATCHED CUSTOM MAILBOX TO BE CONSTRUCTED OF ECO-OUTDOOR
DRYSTONE 'ALPINE' WALL PANELS GLUED ON TOP OF 6MM FIBRE CEMENT
SHEETING APPROPRIATELY FIXED TO A TIMBER WALL FRAMED WALL USING
30MM GAL CLOUTS. THE LOCATION OF THIS WALL AND ASSOCIATED CURVE
WILL BE INDICTIVE AND FOLLOW THE EDGE AND LENGTH OF THE DRIVEWAY AND
THE FRONT OF THE PROPERTY EDGE UNTILL OT REACHES THE MAILBOX AND
FENCE AND THEN CONTINUE UNTILL IT REACHES THE EASTERN FENCE. HEIGHT
OF THE FENCE TO STAY LEVEL ALONG ITS LENGTH.
RETAINING
WALL SEE
DETAIL
HIGHGROVE 9MM TOUGHENED SAFETY
GLASS 1200X1300X12 PANEL
STAINLESS STEEL FIXING TO
MANUFACTURERES SPECIFICATIONS.
SEE BALUSTRADE DETAIL ON W16
INDICTIVE
LOCATION OF
LANDSCAPING
BOULDER
IN GARDEN BED
90MM COLOURBOND LYSAGHT
QUAD GUTTER 'MONUMENT'
FIXED TO MANUFACTURERES SPECS
General Notes SERVICES NOTES
METERBOX/SWITCHBOARD NOTES:
TYPE: RS485 2 WIRE, HALF DUPLEX, ISOLATED
BAUD RATE: 600 TO 19200 BPS
PROTOCOL: MODBUS RTU
FUNCTION: RED/ WRITE SETPOINTS
READ ACTUAL VALUES
EXECUTE COMMANDS
POWER SUPPLY:
INPUT: 100V-240V AC 50/60HZ
100V-300VDC
POWER: 2W
NOTE: BEFORE ANY WORKS BEGIN ON ANY ELECTRICAL CONNECTIONS ON
SITE IT IS ADVISED THAT THE RELEVANT AUTHORITY
SPI NETWORKS BE CONTACTED.
METERBOX/SWTICHBOARD INSTALLATION REQUIREMENTS:
THERE MUST BE A SEPARATION OF 300MM BETWEEN ANY UNDERGROUND
WATER SERVICE PIPE AND AN ELECTRICAL SUPPLY CABLE. ANY WATER
SERVICE PIPE GREATER THAN DN 65 WILL BE INDICATED APPROPRIATELY
ALONG ITS LENGTH AT 150MM ABOVE THE PIPE AND MUST ALSO BE
MECHANICALLY PROTECTED IN ACCORDANCE WITH ASNZS 3500.5, ASNZS
2648 AND ASNZS 3000.
CONDUIT OF DN50 AND CABLES OF DN20 ARE TO BE CONNECTED TO
SWITCHBOARD/METER BOX IN ACCORDANCE WITH ASNZS 3000.
CIRCTUIT BREAKER REQUIREMENTS:
CIRCUIT BREAKERS FOR EACH REQUIRED CIRCUIT ARE TO BE MOUNTED
ONTO A CLEARLY IDENTIFIABLE, SINGLE-PHASE SWITCHBOARD AND
CORRESPOND TO ACTIVE/NEUTRAL CONNECTIONS.
GAS INSTALLATION NOTES:
PIPES USED FOR GAS SUPPLY SYSTEM: COPPER DN10 PIPES.
iNSTALLATION REQUIREMENTS:
THERE MUST BE A SEPARATION OF 300MM BETWEEN ANY UNDERGROUND
WATER SERVICE PIPE AND CONSUMER GAS PIPES. ANY WATER SERVICE PIPE
GREATER THAN DN 65 WILL BE INDICATED APPROPRIATELY ALONG ITS
LENGTH WITH ORANGE MARKER TAPE AT 150MM ABOVE THE PIPE IN
ACCORDANCE WITH ASNZS 2648.1 – UNDERGROUND MARKING TAPE AND ASNZS
5601 – GAS INSTALLATIONS.
NOTE: BEFORE ANY WORKS BEGIN ON ANY GAS CONNECTIONS ON SITE IT IS
ADVISED THAT THE RELEVANT AUTHORITY SPI NETWORKS BE CONTACTED.
WALL MUST BE SARKED AND EXTERNALLY FIXED WITH 6MM CEMENT
SHEETING USING 30MM GAL CLOUTS. 20X50 VERTICAL TIMBER BATTENS TO BE
PLACED AT 600 CNTRS AND FIXED WITH 65MM GAL BATTEN SCREWS. A 12MM
GAP AT THE TOP OF THE WALL AND A 200MM GAP AT THE BOTTOM OF THE
WALL MUST BE LEFT TO ALLOW AIRFLOW BEHIND THE TIMBER CLADDING.
50X50 HORIZONTAL BATTENS TO BE FIXED TO VERTICAL BATTENS AT 600
CNTRS WITH 65MM BATTEN SCREWS. ENSURE A GAP OF 8MM BETWEEN
TIMBER CLADDING AND EDGE BATTEN. EXTRA PEICES OF BATTEN TO BE
ATTATCHED AT JOINTS TO FIX SHORTER PEICES OF CLADDING WHERE
REQUIRED.
50X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS TO BE USED TO FIX
100X25MM TURPENTINE SHADOW CLADDING. IF NAILS ARE LESS THAN 30MM
FROM THE END OF THE PEICE OF TIMBER, A PILOT HOLE MUST BE DRILLED
PRIOR TO FIXING.
END GRAIN TO BE SEALED AND INTERGRAIN REDWOOD STAIN TO BE APPLIED
TO CLADDING AS PER MANUFACTURERES SPECS.
ALL DOORS TO BE INSTALLED TO MANUFACTURERES SPECS
TIMBER CLADDING MUST NOT SIT ON TIMBER FRAME
WATER PROOFING TO OVERHANG OVER DOOR FRAME APPROPRIATELY
TO ENSURE CORRECT WATER RUNOFF AND PREVENT MOISTURE BUILD-
UP.
REFER TO DOOR SCHEDULE FOR DOOR AND GLAZING SPECIFICATIONS.
ALL OPENINGS ARE OF NOMINAL HEIGHT AND LENGTH AND MAY VARY.
ALL SOIL MUST SLOPE AWAY FROM BUILDING FOR A MINIMUM OF 1M.
ARTICULATE MASONRY VENEER WALLS MUST BE CONSTRUCTED IN
ACCORDANCE WITH AS 3700 AND AS 1684.4.
FIRE RESISTANT TURPENTINE TIMBER TO COMPLY WITH AS3959 TIMBER
IN BUSHFIRE PRONE AREAS. APPENDIX E
EXTERNAL CLADDING NOTES
E
G
6443
LETTER BOX
180MM STEP DOWN
ON DECKING.
Scale Checked by
Drawn by
Date Project number
1 : 100
East/West Elevations
P1.0
FINCH STREET NEW DWELLING
MR A AND MRS M METCALF Issue Date
Author
HALEN MOKA
24 FINCH STREET, BEECHWORTH VIC W06
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
1
W08
2
W08
ALUCOBOND SPARKLING
BLACK
METALLIC 888 SEALED
WITH BLACK SILICONE
FIXED WITH B20620
IMPULSE C15
BFP STRAIGHT BRADERS
SKYDOME LOW E DOUBLE GLAZED
BLACK ALUMINIUM FRAME INSTALLED
TO MANUFACTURERES SPECS
COLOURBOND CORRGATED
ROOFING IRON
INSTALLED TO MANUFCTURERES SPECS
'MONUMENT'
90MM COLOURBOND
LYSAGHT
QUAD GUTTER
'MONUMENT'
FIXED TO
MANUFACTURERES
SPECS
COLOURBON IRON RIDGE CAPPING
FIXED TO MANUYFACTURERES
SPECIFICATIONS
'MONUMENT'
100X25
TURPENTINE
CLADDING
INTERGRAIN
REDWOOD
STAIN
FIXED WITH
B20620
IMPULSE C15
BFP STRAIGHT
BRADERS
ALUCOBOND SPARKLING
BLACK
METALLIC 888 SEALED
WITH BLACK SILICONE
FIXED WITH B20620
IMPULSE C15
BFP STRAIGHT BRADERS
90MM COLOURBOND LYSAGHT
QUAD GUTTER 'MONUMENT'
FIXED TO MANUFACTURERES SPECS
DN 100 TYPE C METAL DOWNPIPE 'MONUMENT'
LOW GLOSS FINISH
220mm X 140mm METAL RAINWATER HEAD
FIXED TO CLADDING USING MANUFACTURERS
SPECS
100X25 TURPENTINE DECKING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED WITH 50MM
GAL SELF DRILLING DECKING SCREWS
COLOURBOND CORRGATED
ROOFING IRON
INSTALLED TO MANUFCTURERES SPECS
'MONUMENT'
HIGHGROVE 9MM TOUGHENED SAFETY
GLASS 1200X1300X12 PANEL
STAINLESS STEEL FIXING TO
MANUFACTURERES SPECIFICATIONS
SEE BALUSTRADE DETAIL ON W16
INDICTIVE POSITION OF PREMIUM LINE
GERMAN SOLAR, SOLAR PANELS
INSTALLED TO MANUFACTURERES
SPECIFICATIONS
INDICTIVE POSITION OF PHOTOVOLTAICS FOR
SOLAR HOT WATER SYSTEM
INSTALLED TO MANUFACTURERES SPECs
SKYDOME LOW E DOUBLE GLAZED
BLACK ALUMINIUM FRAME INSTALLED
TO MANUFACTURERES SPECS
100X25 TURPENTINE CLADDING
INTERGRAIN REDWOOD STAIN
FIXED WITH B20620 IMPULSE C15
BFP STRAIGHT BRADERS
100X25 TURPENTINE
DECKING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED
WITH 50MM
GAL SELF DRILLING
SCREWS
.
ECO OUT DOOR
DRYSTONE PAVERS
"ALPINE"
INSTALLED TO
MANUFACTURERES
SPECS
0201
03
04
05
06
14
SCHWEISS CUSTOM DESIGNED BI-FOLD
MECHANICAL DOORS INSTALLED TO
MANUFACTURERES SECS.
WITH 100X25 TURPENTINE CLADDING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED WITH 50MM
GAL CLOUTS
07
WALL MUST BE SARKED AND EXTERNALLY
FIXED WITH 6MM CEMENT SHEETING USING 30MM
GAL CLOUTS.
20X50 VERTICAL TIMBER BATTENS TO BE
PLACED AT 600 CNTRS AND FIXED WITH 65MM
GAL BATTEN SCREWS.
A 12MM GAP AT THE TOP OF THE WALL AND A
200MM GAP AT THE BOTTOM OF THE WALL
MUST BE LEFT TO ALLOW AIRFLOW BEHIND
THE TIMBER CLADDING.
50X50 HORIZONTAL BATTENS TO BE FIXED TO
VERTICAL BATTENS AT 600 CNTRS WITH 65MM
BATTEN SCREWS.
ENSURE A GAP OF 8MM BETWEEN TIMBER
CLADDING AND EDGE BATTEN.
ALL DOORS TO BE INSTALLED TO
MANUFACTURERES SPECS
TIMBER CLADDING MUST NOT SIT ON TIMBER
FRAME
WATER PROOFING TO OVERHANG OVER DOOR
FRAME APPROPRIATELY
TO ENSURE CORRECT WATER RUNOFF AND
PREVENT MOISTURE BUILD-UP.
REFER TO DOOR SCHEDULE FOR DOOR AND
GLAZING SPECIFICATIONS.
ALL SOIL MUST SLOPE AWAY FROM
BUILDING FOR A MINIMUM OF 1M.
ALL OPENINGS ARE OF NOMINAL HEIGHT
AND LENGTH AND MAY VARY.
DOWNPIPES MUST BE INSTALLED IN
ACCORDANCE WITH AS 3500.
ALL OPENINGS ARE OF NOMINAL HEIGHT
AND LENGTH AND MAY VARY.
GAS METER AND METER BOX TO BE
INSTALLED BY ELECTRICIAN CORRECTLY.
REFER TO NOTES ON W05.
FEATURE WALL AND STONE WALL AT
THE FRONT OF THE PROPERTY AND
ATTATCHED CUSTOM MAILBOX TO BE
CONSTRUCTED OF ECO-OUTDOOR
DRYSTONE 'ALPINE' WALL PANELS
GLUED ON TOP OF 6MM FIBRE CEMENT
SHEETING APPROPRIATELY FIXED TO A
TIMBER WALL FRAMED WALL USING
30MM GAL CLOUTS. THE LOCATION
EXTRA PEICES OF BATTEN TO BE ATTATCHED
AT JOINTS TO FIX SHORTER PEICES OF CLADDING
WHERE REQUIRED.
50X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN
NAILS TO BE USED TO FIX 100X25MM TURPENTINE
SHADOW CLADDING.
IF NAILS ARE LESS THAN 30MM FROM THE END
OF THE PEICE OF TIMBER, A PILOT HOLE MUST
BE DRILLED PRIOR TO FIXING.
END GRAIN TO BE SEALED AND INTERGRAIN
REDWOOD STAIN TO BE APPLIED TO CLADDING AS
PER MANUFACTURERES SPECS.
SCHWEISS CUSTOM DESIGNED MECHANICAL DOORS INSLALLED TO MANUFACTURERES SPECIFICATIONS WITH
100X25 TURPENTINE CLADDING AND INTERGRAIN REDWOOD NATURAL STAIN. TO BE FIXED WITH 50MM GAL
CLOUTS. ELECTRONIC MECHANICAL ARMS AND HYDROLICS SPECIFIED AND INSTALLED BY MANUFACTURERE.
EXTERNAL CLADDING NOTES
MECHANICAL GARAGE DOOR
General Notes
INDICTIVE POSITION OF 2500L
RHEEM PREMIER® HILINE SOLAR
HOT WATER HEATER GAS
BOOSTED.
MODEL: 52H180K/1S-G
INSTALLED TO
MANUFACTURERES
SPECIFICATIONS
ARTICULATE MASONRY VENEER WALLS
MUST BE CONSTRUCTED IN ACCORDANCE
WITH AS 3700 AND AS 1684.4.
OF THIS WALL AND ASSOCIATED CURVE
WILL BE INDICTIVE AND FOLLOW THE
EDGE AND LENGTH OF THE DRIVEWAY
AND THE FRONT OF THE PROPERTY
EDGE UNTILL OT REACHES THE MAILBOX
AND FENCE AND THEN CONTINUE UNTILL
IT REACHES THE EASTERN FENCE. HEIGHT
OF THE FENCE TO STAY LEVEL ALONG
ITS LENGTH.
FEATURE WALL TO BE
CONSTRUCTED FROM ECO
OUTDOOR DRYSTONE
PANELS
FOR CONSTRUCTION
DETAILS SEE GENERAL
NOTES.
20MPA CONCRETE DRIVEWAY
1
W08
2
W08
8 9
10
ALUCOBOND SPARKLING BLACK
METALLIC 888 SEALED WITH BLACK SILICONE
FIXED WITH B20620 IMPULSE C15
BFP STRAIGHT BRADERS
SKYDOME LOW E DOUBLE GLAZED
BLACK ALUMINIUM FRAME INSTALLED
TO MANUFACTURERES SPECS
COLOURBOND CORRGATED ROOFING IRON
INSTALLED TO MANUFCTURERES SPECS 'MONUMENT'
90MM COLOURBOND LYSAGHT
QUAD GUTTER 'MONUMENT'
FIXED TO MANUFACTURERES SPECS
DN 100 TYPE C METAL DOWNPIPE 'MONUMENT'
LOW GLOSS FINISH
220mm X 140mm METAL RAINWATER HEAD
FIXED TO CLADDING USING MANUFACTURERS SPEC
COLOURBON IRON RIDGE CAPPING
FIXED TO MANUYFACTURERES SPECIFICATIONS
'MONUMENT'
100X25 TURPENTINE CLADDING
INTERGRAIN REDWOOD STAIN
FIXED WITH B20620 IMPULSE C15
BFP STRAIGHT BRADERS
ALUCOBOND SPARKLING BLACK
METALLIC 888 SEALED WITH BLACK
SILICONE
FIXED WITH B20620 IMPULSE C15
BFP STRAIGHT BRADERS
90MM COLOURBOND LYSAGHT
QUAD GUTTER 'MONUMENT'
FIXED TO MANUFACTURERES SPECS
DN 100 TYPE C METAL DOWNPIPE
'MONUMENT'
LOW GLOSS FINISH
220mm X 140mm METAL RAINWATER
HEAD
FIXED TO CLADDING USING
MANUFACTURERS SPECS
HIGHGROVE 9MM TOUGHENED SAFETY
GLASS 1200X1300X12 PANEL
STAINLESS STEEL FIXING TO
MANUFACTURERES SPECIFICATIONS
SEE BALUSTRADE DETAIL ON W16
INDICTIVE POSITION OF PREMIUM LINE
GERMAN SOLAR, SOLAR PANELS
INSTALLED TO MANUFACTURERES SPECIFICATIONS
INDICTIVE POSITION OF PHOTOVOLTAICS FOR SOLAR
HOT WATER SYSTEM
INSTALLED TO MANUFACTURERES SPECIFICATIONS
INDICTIVE POSITION OF 2500L RHEEM PREMIER®
HILINE SOLAR HOT WATER HEATER GAS
BOOSTED. MODEL: 52H180K/1S-G
INSTALLED TO MANUFACTURERES SPECS
SKYDOME LOW E DOUBLE GLAZED
BLACK ALUMINIUM FRAME INSTALLED
TO MANUFACTURERES SPECS
100X25 TURPENTINE DECKING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED WITH 50MM
GAL SELF DRILLING SCREWS
.
19 21
2838
2869571
5567
FEATURE WALL TO BE
CONSTRUCTED FROM ECO
OUTDOOR DRYSTONE PANELS
FOR CONSTRUCTION DETAILS
SEE GENERAL NOTES.
Scale Checked by
Drawn by
Date Project number
1 : 50
North/ South
Elevations
P1.0
FINCH STREET NEW DWELLING
MR A AND MRS M METCALF Issue Date
Author
HALEN MOKA
24 FINCH STREET, BEECHWORTH VIC W07
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
1
W09
ALL DOORS TO BE INSTALLED TO MANUFACTURERES SPECS
TIMBER CLADDING MUST NOT SIT ON DOOR FRAME.
WATER PROOFING TO OVERHANG OVER DOOR FRAME APPROPRIATELY
TO ENSURE CORRECT WATER RUNOFF AND PREVENT MOISTURE BUILD-
UP AND WATER INGRESS.
REFER TO DOOR SCHEDULE FOR DOOR AND GLAZING SPECIFICATIONS.
ALL STRUCTURAL STEEL TO BE PROTECTED IN ACCORDANCE WITH
AS2312.
ALL BRICKWORK TO BE CONSTRUCTED IN ACCORDANCE WITH AS4773
MASONRY IN SMALL BUILDINGS.
FORMWORK FOR CONCRETE SLAB TO BE CONSTRUCTED IN
ACCORDANCE WITH AS3610 FORMWORK FOR CONCRETE.
RETAINING WALL TO BE BUILT IN ACCORDANCE WITH AS4678 EARTH
RETAINING STRUCTURES.
ALL STORMWATER GUTTERS, PIPES AND SERVICES TO BE
CONSTRUCTED IN ACCORDANCE WITH ASNZS 3500.3 PASRT 3
STORMWATER DRAINAGE
ALL CONCRETE STRUCTURES TO BE CONSTRUCTED IN ACCORDANCE
WITH AS 3600 CONCRETE STRUCTURES. CONCRETE SLAB TO
CONSTRUCTED IN ACCORDANCE WITH AS2870 RESIDENTIAL SLABS AND
FOOTINGS.
TIMBER CLADDING SPECIFICATIONS:
WALL MUST BE SARKED AND EXTERNALLY FIXED WITH 6MM CEMENT
SHEETING USING 30MM GAL CLOUTS. 20X50 VERTICAL TIMBER BATTENS
TO BE PLACED AT 600 CNTRS AND FIXED WITH 65MM GAL BATTEN
SCREWS. A 12MM GAP AT THE TOP OF THE WALL AND A 200MM GAP AT
THE BOTTOM OF THE WALL MUST BE LEFT TO ALLOW AIRFLOW
BEHIND THE TIMBER CLADDING.
50X50 HORIZONTAL BATTENS TO BE FIXED TO VERTICAL BATTENS AT
600 CNTRS WITH 65MM BATTEN SCREWS. ENSURE A GAP OF 8MM
BETWEEN TIMBER CLADDING AND EDGE BATTEN.
EXTRA PEICES OF BATTEN TO BE ATTATCHED AT JOINTS TO FIX
SHORTER PEICES OF CLADDING WHERE REQUIRED.
50X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS TO BE USED TO FIX
100X25MM TURPENTINE SHADOW CLADDING. IF NAILS ARE LESS THAN
30MM FROM THE END OF THE PEICE OF TIMBER, A PILOT HOLE MUST
BE DRILLED PRIOR TO FIXING.
END GRAIN TO BE SEALED AND INTERGRAIN REDWOOD STAIN TO BE
APPLIED TO CLADDING AS PER MANUFACTURERES SPECS.
ALUCOBOND® PLUS SPECIFICATIONS:
ALUCOBOND® PLUS ALUMINIUM COMPOSITE MATERIAL (ACM) SHALL BE
6MM THICK AND CONSIST OF 2 LAYERS OF 0.5MM THICK ALUMINIUM
SANDWICHING A MINERAL FILLED FIRE RESISTANT CORE CONTAINING 70%
NON COMBUSTIBLE MINERAL FILLING.
THE ALUMINIUM SKINS SHALL BE OF ALLOY ALMG 1- NS41 (EN AW 5005A
NEAREST EQUIVALENT) HAVING AN ULTIMATE STRENGTH OF 130 MPA
AND 0.2% PROOF STRESS OF 90 MPA. ALUCOBOND SHEETING MUST BE
FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS EVERY
100MM AROUND THE EDGES TO TIMBER BATTENS AND STUDS. BE SURE
TO FIX EXTRA TIMBER PEICES AROUND ALUCOBOND EDGES WHERE
THERE ARE GAPS AND NO TIMBER TO FIX TO.
VELUX ROOF WINDOWS SPECIFICATIONS:
VELUX ROOF WINDOWS AND MATERIALS THAT IT CONSISTS OF TO MEET
THE REQUIREMENTS OF AS4285 SKYLIGHTS, AS1288 OVERHEAD GLAZING
AND AS3959 BUSHFIRE FOR BAL 40 REQUIREMENTS AND AS1530.1 NON-
COMBUSTIBILITY.. MUST BE INSTALLED TO MANUFACTURERES
SPECIFICATIONS AND SEALED APPROPRIATELY TO ENSURE THERE IS NO
WATER INGRESS. SEE DETAIL ON W16
CONCRETE SPECIFICATION:
300X300 INTERNAL BEAMS TO CONTAIN 3-L11TM REINFORCMENT STEEL
30MM FROM BOTTOM OF BEAM AND @ 6M MAX CTRS.
GARAGE SLAB FFL 8864.
400X300 EXTERNAL EDGE BEAMS TO CONTAIN 3-L11TM REINFORCEMENT
MESH 30MM FROM BOTTOM OF BEAM.
CONCRETE MANUFACTURED MUST BE IN ACCORDANCE WITH AS3700
STANDARD CORE 13MM PLASTERBOARD TO BE FIXED ALONG WALLS
STUDS AND 15MM FROM SHEET EDGES AND ENDS WITH 30MM 'W' TYPE
PLASTERBOARD SCREWS. SERVIES MUST BE IN PLACE BEFORE
INSTALLATION. ENSURE FRAMING IS PLUMB, LEVEL &SQUARE AND THAT
THE AREA IS WEATHER PROOF. ENSURE THAT STUD SPACING TAKES
INTO ACCOUNT THE WIDTH OF PLASTERBOARD SHEETS AND ALLOWS
FIXING POINTS AT ITS EDGES.
ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION MUST COMPLY
WITH AS2589-GYPSUM LININGS.
ALUCOBOND SPARKLING BLACK
METALLIC 888 SEALED WITH BLACK
SILICONE
FIXED WITH B20620 IMPULSE C15
BFP STRAIGHT BRADERS
COLOURBOND CORRGATED
ROOFING IRON
INSTALLED TO MANUFCTURERES SPECS
'MONUMENT'
ALUCOBOND SPARKLING
BLACK
METALLIC 888 SEALED
WITH BLACK SILICONE
FIXED WITH B20620
IMPULSE C15
BFP STRAIGHT BRADERS
COLOURBON IRON RIDGE CAPPING
FIXED TO MANUYFACTURERES SPECIFICATIONS
'MONUMENT'
100X25 TURPENTINE DECKING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED WITH 50MM
GAL CLOUTS
100X25 TURPENTINE CLADDING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED WITH 50MM
GAL CLOUTS
HIGHGROVE TOUGHENED SAFETY
GLASS 1200X1300X12 PANEL
STAINLESS STEEL FIXING TO
MANUFACTURERES
SPECIFICATIONS
25001855
lower floor
level 1
level 2
higher floor
500
0
3000
4855
30001855
100X25 TURPENTINE CLADDING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED WITH 50MM
GAL CLOUTS
ROOFSPACE ROOFSPACE
90MM TIMBER STUD WALL WITH
CHARCOAL NORSTONE ROCK PANEL
CLADDING INSTALLED
MANUFACTURERES SPECS..
180X45 MGP10 RAFTER
FIXED TO 35X90 MGP10 ROOF BATTENS @900MM
CNTRS WITH 100X2.8MM BRIGHT 'D' HEAD MACHINE
DRIVEN NAILS. BATTENS SHOULD BE FIXED WITH
3.1MMX90MM GAL SHANK NAILS @450MM CNTRS
STANDARD CORE 13MM PLASTERBOARD TO BE FIXED
ALONG WALLS STUDS AND 15MM FROM SHEET EDGES
AND ENDS WITH 30MM 'W' TYPE PLASTERBOARD
SCREWS. CEILING MUST HAVE PEER 16X6000MM
0.38BMT DOMESTIC CEILING BATTEN FCDB-60 @450
CNTRS INSTALLED TO MANUFACTURERES SPECS
PRIOR TO FIXING PLASTERBOARD. ALL PLASTERBOARD
AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH
AS2589-GYPSUM LININGS.
STANDARD CORE 13MM
PLASTERBOARD TO BE
FIXED ALONG WALLS
STUDS AND 15MM FROM
SHEET EDGES AND
ENDS WITH 30MM 'W'
TYPE PLASTERBOARD
SCREWS.
DW
STANDARD CORE 13MM
PLASTERBOARD TO BE
FIXED ALONG WALLS
STUDS AND 15MM FROM
SHEET EDGES AND
ENDS WITH 30MM 'W'
TYPE PLASTERBOARD
SCREWS.
500MM FLOOR HEIGHT
CHANGE. SEE DETAIL ON
W16.
150MM CONCRETE SLAB TO BE
CONSTRUCTED IN ACCORDANCE WITH
AS2870 AND USING SL82 AS
REINFORCEMENT MESH 30MM FROM
TOP.
R2.7 1160X580 HIGH PERFORMANCE
GOLD BRADFORD INSULATION BATTS
CUT TO FIT SECURED WITH 13MM
STANDARD CORE PLASTERBOARD.
10 5 4 3 2
17
1
1
INTERNAL REINFORCED
CONCRETE BEAM 300X300
GENERAL NOTES
external cladding notes
INTERNAL cladding notes
1
W09
ALUCOBOND SPARKLING
BLACK
METALLIC 888 SEALED
WITH BLACK SILICONE
FIXED WITH B20620
IMPULSE C15
BFP STRAIGHT BRADERS
COLOURBOND CORRGATED
ROOFING IRON
INSTALLED TO MANUFCTURERES SPECS
'MONUMENT'
ALUCOBOND SPARKLING
BLACK
METALLIC 888 SEALED
WITH BLACK SILICONE
FIXED WITH B20620
IMPULSE C15
BFP STRAIGHT BRADERS
R2.7 1160X580 HIGH PERFORMANCE GOLD
BRADFORD INSULATION BATTS CUT TO FIT
SECURED WITH 13MM STANDARD CORE
PLASTERBOARD.
100X25 TURPENTINE DECKING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED WITH 50MM
GAL CLOUTS
100X25 TURPENTINE CLADDING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED WITH 50MM
GAL CLOUTS
HIGHGROVE TOUGHENED SAFETY
GLASS 1200X1300X12 PANEL
STAINLESS STEEL FIXING TO
MANUFACTURERES
SPECIFICATIONS
100X25 TURPENTINE CLADDING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED WITH 50MM
GAL CLOUTS
180X45 MGP10 RAFTER
FIXED TO 35X90 MGP10 ROOF BATTENS @900MM
CNTRS WITH 100X2.8MM BRIGHT 'D' HEAD MACHINE
DRIVEN NAILS. BATTENS SHOULD BE FIXED WITH
3.1MMX90MM GAL SHANK NAILS @450MM CNTRS
STANDARD CORE 13MM PLASTERBOARD TO BE FIXED
ALONG WALLS STUDS AND 15MM FROM SHEET EDGES
AND ENDS WITH 30MM 'W' TYPE PLASTERBOARD
SCREWS. CEILING MUST HAVE PEER 16X6000MM
0.38BMT DOMESTIC CEILING BATTEN FCDB-60 @450
CNTRS INSTALLED TO MANUFACTURERES SPECS
PRIOR TO FIXING PLASTERBOARD. ALL PLASTERBOARD
AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH
AS2589-GYPSUM LININGS.
STANDARD CORE 13MM
PLASTERBOARD TO BE
FIXED ALONG WALLS
STUDS AND 15MM FROM
SHEET EDGES AND
ENDS WITH 30MM 'W'
TYPE PLASTERBOARD
SCREWS.
500MM FLOOR HEIGHT
CHANGE. SEE DETAIL ON
W15.
150MM CONCRETE SLAB TO BE
CONSTRUCTED IN ACCORDANCE WITH
AS2870 AND USING SL82 AS
REINFORCEMENT MESH 30MM FROM
TOP.
INTERNAL REINFORCED
CONCRETE BEAM
300X300
100X25 TURPENTINE CLADDING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED WITH
50MM GAL CLOUTS
18
9
14
20
17
EXTERNAL REINFORCED
CONCRETE BEAM
300X400
6MM FIBRE CEMENT
SHEETING FIXED TO
2X180X45MM MGP10 RAFTERS
W/ 50MM GAL CLOUTS
lower floor
level 1
0
3700
3700
higher floor
500
LEVEL 1
3200
300MM MGP10 STUD WALL.
500MM HIGH WITH 13MM STANDARD CORE
PLASTERBOARD PAINTED 'NATURAL WHITE'
Scale Checked by
Drawn by
Date Project number
1 : 100
Sections
P1.0
FINCH STREET NEW DWELLING
MR A AND MRS M METCALF Issue Date
Author
HALEN MOKA
24 FINCH STREET, BEECHWORTH VIC W08
1 : 100
Section 3
1
1 : 100
Section 5
2
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
1
W08
2
W08
90MM STUD WALL WITH 80MM
INSULATION BATTS.
6MM FIBRE CEMENT SHEETING
TO BE FIXED TO STUDS
OVER WATER PROOFING
MEMBRANE.
20X50MM VERTICAL BATTENS TO
BE FIXED TO CEMENT SHEETING
AND
50X50MM HORIZONTAL BATTENS
TO BE FIXED TO VERTICAL
BATTENS.
SEE GENERAL NOTES FOR
CONSTRUCTION METHODS.
COLOURBOND CORRGATED ROOFING IRON
INSTALLED TO MANUFCTURERES SPECS
'MONUMENT'
200X38MM TURPENTINE FASCIA BOARD
FIXED W/50MM GAL FLATHEAD NAILS
COLOURBON IRON RIDGE CAPPING
FIXED TO MANUYFACTURERES SPECIFICATIONS
'MONUMENT'
100X25 TURPENTINE DECKING
INTERGRAIN REDWOOD STAIN
FIXED WITH 50MM GAL SELF-DRILLING SCREWS
SEE DECKING DETAIL ON W15
ALUCOBOND SPARKLING BLACK
METALLIC 888 SEALED WITH
BLACK SILICONE
FIXED WITH B20620 IMPULSE C15
BFP STRAIGHT BRADERS
90MM COLOURBOND LYSAGHT
QUAD GUTTER 'MONUMENT'
FIXED TO MANUFACTURERES SPECS
DN 100 TYPE C U-PVC DOWNPIPE
'MONUMENT'
LOW GLOSS FINISH
220mm X 140mm METAL RAINWATER
HEAD
FIXED TO CLADDING USING
MANUFACTURERS SPECS
100X25 TURPENTINE DECKING
INTERGRAIN REDWOOD 'NATURAL' STAIN
FIXED
FIXED WITH 50MM GAL SELF-DRILLING
SCREWS
SEE DECKING DETAIL ON W15
HIGHGROVE TOUGHENED SAFETY
GLASS 1200X1300X12 PANEL
STAINLESS STEEL FIXING TO
MANUFACTURERES SPECIFICATIONS
SEE W15.
INDICTIVE POSITION OF PREMIUM LINE
GERMAN SOLAR, SOLAR PANELS
INSTALLED TO MANUFACTURERES SPECIFICATIONS
INDICTIVE POSITION OF PHOTOVOLTAICS FOR
SOLAR HOT WATER SYSTEM
INSTALLED TO MANUFACTURERES
SPECIFICATIONS
INDICTIVE POSITION OF 2500L RHEEM PREMIER®
HILINE SOLAR HOT WATER HEATER GAS BOOSTED.
MODEL: 52H180K/1S-G
INSTALLED TO MANUFACTURERES SPECIFICATIONS
SKYDOME LOW E DOUBLE GLAZED
BLACK ALUMINIUM FRAME INSTALLED
TO MANUFACTURERES SPECS AND SEALED APPROPRIATELY
100X25 TURPENTINE CLADDING
INTERGRAIN REDWOOD STAIN
FIXED WITH 50MM GAL SELF DRILLING SCREWS
150MM CONCRETE SLAB TO BE CONSTRUCTED IN
ACCORDANCE WITH AS2870 AND USING SL82 AS
REINFORCEMENT MESH 30MM FROM TOP.
300MM TIMBER FRAMED PARTITION WALL
WITH 13MM PLASTERBOARD LINING
2x240x45 MGP12 RIDGEBOARD
FIXED W/ PRYDA 100X35X1.0MM
MULTIGRIP BRACKET AND 50MM GAL NAILS
35X90 MGP10 ROOF BATTENS @450MM SPACES
FIXED WITH 3.1MMX90MM GAL SHANK NAILS
PEER 16X6000MM 0.38BMT
DOMESTIC CEILING BATTEN FCDB-60 @450 CNTRS
TO BE INSTALLED TO MANUFACTURERES SPECS
HIGHGROVE TOUGHENED SAFETY
GLASS 1200X1300X12 PANEL
STAINLESS STEEL FIXING TO
MANUFACTURERES SPECIFICATIONS
GENERAL NOTES
ALL DOORS TO BE INSTALLED TO MANUFACTURERES SPECS
TIMBER CLADDING MUST NOT SIT ON TIMBER FRAME
WATER PROOFING TO OVERHANG OVER DOOR FRAME APPROPRIATELY
TO ENSURE CORRECT WATER RUNOFF AND PREVENT MOISTURE BUILD-UP.
REFER TO DOOR SCHEDULE FOR DOOR AND GLAZING SPECIFICATIONS.
ALL STRUCTURAL STEEL TO BE PROTECTED IN ACCORDANCE WITH AS2312.
ALL BRICKWORK TO BE CONSTRUCTED IN ACCORDANCE WITH AS4773
MASONRY IN SMALL BUILDINGS.
FORMWORK FOR INSITU CONCRETE WALL TO BE CONSTRUCTED IN
ACCORDANCE WITH AS3610 FORMWORK FOR CONCRETE.
RETAINING WALL TO BE BUILT IN ACCORDANCE WITH AS4678 EARTH
RETAINING STRUCTURES.
ALL STORMWATER GUTTERS, PIPES AND SERVICES TO BE CONSTRUCTED IN
ACCORDANCE WITH ASNZS 3500.3 PASRT 3 STORMWATER DRAINAGE
ALL CONCRETE STRUCTURES TO BE CONSTRUCTED IN ACCORDANCE WITH
AS 3600 CONCRETE STRUCTURES. CONCRETE SLAB TO CONSTRUCTED IN
ACCORDANCE WITH AS2870 RESIDENTIAL SLABS AND FOOTINGS.
90MM COLOURBOND LYSAGHT
QUAD GUTTER 'MONUMENT'
FIXED TO MANUFACTURERES SPECS
DN 100 TYPE C U-PVC DOWNPIPE 'MONUMENT'
LOW GLOSS FINISH
220mm X 140mm METAL RAINWATER HEAD
FIXED TO CLADDING USING MANUFACTURERS
SPEC
200X38MM TURPENTINE FASCIA BOARD
FIXED W/50MM GAL FLATHEAD NAILS
200X125MM STEEL RHS
INSTALLED AND FIXED TO
ENGINEERS SPECS
PRYDA 130X90MM HEAVY DUTY
GAL STEEL STIRRUP POST ANCHOR
200X200X500 CONCRETE
FOOTING
90MM TIMBER STUD WALL WITH CHARCOAL
NORSTONE ROCK PANEL CLADDING INSTALLED
MANUFACTURERES SPECS..
150X100UA10 STEEL ANGLE BEAM
TO BE INSTALLED TO ENGINEERS SPECS
SLIDING DOOR TO BE INSTALLED TO
MANUFACTURERES SPECS
external cladding NOTES
WALL MUST BE SARKED AND EXTERNALLY FIXED WITH 6MM CEMENT
SHEETING USING 30MM GAL CLOUTS. 20X50 VERTICAL TIMBER BATTENS TO
BE PLACED AT 600 CNTRS AND FIXED WITH 65MM GAL BATTEN SCREWS.
A 12MM GAP AT THE TOP OF THE WALL AND A 200MM GAP AT THE
BOTTOM OF THE WALL MUST BE LEFT TO ALLOW AIRFLOW BEHIND THE
TIMBER CLADDING.
50X50 HORIZONTAL BATTENS TO BE FIXED TO VERTICAL BATTENS AT 600
CNTRS WITH 65MM BATTEN SCREWS. ENSURE A GAP OF 8MM BETWEEN
TIMBER CLADDING AND EDGE BATTEN.
EXTRA PEICES OF BATTEN TO BE ATTATCHED AT JOINTS TO FIX
SHORTER PEICES OF CLADDING WHERE REQUIRED.
50X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS TO BE USED TO FIX
100X25MM TURPENTINE SHADOW CLADDING. IF NAILS ARE LESS THAN 30MM
FROM THE END OF THE PEICE OF TIMBER, A PILOT HOLE MUST BE
DRILLED PRIOR TO FIXING. END GRAIN TO BE SEALED AND INTERGRAIN
REDWOOD STAIN TO BE APPLIED TO CLADDING AS PER MANUFACTURERES
SPECS.
FEATURE WALL AND STONE WALL AT THE FRONT OF THE PROPERTY AND
ATTATCHED CUSTOM MAILBOX TO BE CONSTRUCTED OF ECO-OUTDOOR
DRYSTONE 'ALPINE' WALL PANELS GLUED ON TOP OF 6MM FIBRE CEMENT
SHEETING APPROPRIATELY FIXED TO A TIMBER WALL FRAMED WALL USING
30MM GAL CLOUTS. THE LOCATION OF THIS WALL AND ASSOCIATED
CURVE WILL BE INDICTIVE AND FOLLOW THE EDGE AND LENGTH OF THE
DRIVEWAY AND THE FRONT OF THE PROPERTY EDGE UNTILL OT REACHES
THE MAILBOX AND FENCE AND THEN CONTINUE UNTILL IT REACHES THE
EASTERN FENCE. HEIGHT OF THE FENCE TO STAY LEVEL ALONG ITS
LENGTH.
SERVICES MUST BE IN PLACE BEFORE INSTALLATION. ENSURE FRAMING IS
PLUMB, LEVEL &SQUARE AND THAT THE AREA IS WEATHER PROOF.
ENSURE THAT STUD SPACING TAKES INTO ACCOUNT THE WIDTH OF
PLASTERBOARD SHEETS AND ALLOWS FIXING POINTS AT ITS EDGES.
STANDARD CORE 13MM PLASTERBOARD TO BE FIXED ALONG WALLS
STUDS AND 15MM FROM SHEET EDGES AND ENDS WITH 30MM 'W' TYPE
PLASTERBOARD SCREWS .
CEILING MUST HAVE PEER 16X6000MM 0.38BMT DOMESTIC CEILING
BATTEN FCDB-60 @450 CNTRS INSTALLED TO MANUFACTURERES
SPECS PRIOR TO FIXING PLASTERBOARD. ALL PLASTERBOARD AND ITS
RESPECTIVE INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS.
INTERIOR FEATURE WALL TO BE A 90MM TIMBER STUD WALL WITH
CHARCOAL NORSTONE ROCK PANEL CLADDING INSTALLED TO
MANUFACTURERES SPECS.. WALL TO RUN THE LENGTH OF THE HOUSE.
FINISHED FLOOR SURFACE ALONG HALLWAY TO BE CONSTRUCTED OF
POLISHED CONCRETE. LIVING SPACES INCLUDING BEDROOMS, KITCHEN
,LIVING ROOM AND DINING TO BE 100X25 TURPENTINE SHIPLAP TIMBER
FLOORING WITH NATURAL STAIN. FOR LOCATION OF FLOOR TYPES AND
AREA SEE W10.
BATHROOMS AND LAUNDRY FLOORS TO BE TILED WITH GLAZED POPAR
LIGHT GREY BEAUMONT FLOOIRING TILES WITH A LIGHT GREY MORTAR.
WATERPROOFING TO OCCUR IN THESE AREAS APPROPRIATELY. SEE WET
AREA DETAIL ON W15.
INTERNAL LINING NOTES
19
20
17
SEE INTERNAL
ELEVATION
124.04°
152.21°
96.92°
PARTITION WALL
AND SHELVING
90MM TIMBER FRAMED
STUD WALL WITH 13MM
PLASTERBOARD.
REF
Scale Checked by
Drawn by
Date Project number
As indicated
Sections II
P1.0
FINCH STREET NEW DWELLING
MR A AND MRS M METCALF Issue Date
Author
HALEN MOKA
24 FINCH STREET, BEECHWORTH VIC W09
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
MASTER BEDROOM
ENSUITE
WIR
DOUBLE GARAGE
STORAGE
LIVING KITCHEN
DINING
BATH
LAUNDRY
BED 1
BED 2
STUDY
DECKING
2
1
FFL400
FFL1190
UP
OVERHEAD ROOF LINE
SL
SL
SL
SL
SL
SL
SL
LEGEND
ELECTRICAL CABLES
TYPE A
TYPE B
TYPE E
TYPE C
SMOKE ALARM
TYPE D
DOUBLE GENERAL POWER OUTLET
1 POINT LIGHT SWITCH
2 POINT LIGHT SWITCH
3 POINT LIGHT SWITCH
METERBOX
DOUBLE GENERAL POWER OULET
TELEPHONE CONNECTION POINT
TELEVISION POINT
ST
RH
REF
PTY
DW
WMDR
N
O
RTH
SMOKE DETECTORS TO BE INSTALLED IN ACCORDANCE WITH AS 3786-1993
ALL ELECTRICAL INSTALLATION MUST MEET THE REQUIREMENTS OF AS
3000.
SMOKE ALARMS LOCATED AT THE FRONT END OF THE HALLWAY, THE
END OF THE HALLWAY AND NEAR THE DOOR TO THE GARAGE IN THE
LIVING ROOM. EXACT POSITIONING TO COMPLY WITH BCA CL: 3.7.2.3
ALL ELECTRICAL WORKS TO BE CONDUCTED BY A REGISTERED
ELECTRIAN.
LIGHTING FIXTURES AND LOCATIONS MUST BE INSTALLED IN ACCORDANCE
WITH AS1680.
MECHANICAL VENTILATION TO COMPLY WITH AS1668.
General Notes
TYPE: A QUANTITY: 9
MINIWOODY LED 42W FACADE LAMP
LED SPOT LAMP FOR CEILING/WALL MOUNTED SPOT LIGHTING.
TYPE: B QUANTITY: 57
LEDLUX 14W 92MM NON-DIMMABLE CNC ALUMINIUM ROUND DOWN LIGHT.
CEILING MOUNTED DOWNLIGH FOR AMBIENT LIGHTING.
TYPE: C QUANTITY: 4
T5 STARCOAT 80W LINEAR FLUROSCENT LAMP FOR CEILING MOUNTED
GARAGE LIGHTS.
TYPE: D QUANTITY: 8
THERMALITE DELUXE 3 IN 1 BATHROOM HEATER 4X275W HEAT LAMPS.
STAINLESS STEEL HOUSING WITH BUILT IN EXHAUST AND HEAT LAMPS.
TYPE: E QUANTITY: 59
HPM 12V 0.3W LED DECK LIGHTS.
RECESSED DECKING LIGHTS AND PERIMETER POOL LIGHTING.
SMOKE ALARM TYPE:
WORMWALD TYCO 614P PHOTOELECTRIC SMOKE DETECTOR.
LIGHTING TYPES
ELECTRICAL CONTRACTOR TO BE SOLELY RESPONSIBLE FOR FOR
STRICT COMPLIANCE WITH ALL SAFETY STANDARDS, REGULATIONS AND
AUTHORITY REGULATIONS.
CONTRACTOR REQUIRED TO ENSURE ALL ELECTRICAL WORK TO BE
TESTED BY THE RESPINSOBLE ELECTRICAL SUPPLY AUTHORITY AFTER
THE COMPLETETION AND INSTALLTION OF ALL WORKS INVOLVED.
ANY CERTIFICATES, PERMITS AND APPROVALS ARE TO BE FOWARDED TO
OWNER AS THEY ARE RECIEVED.
UNLESS OTHERWISE NOTED ALL GPO'S TO BE FLAT 3 PIN TYPE. SEE
DRAWING FOR LOCATIONS.
ALL GPO'S EXCEPT FOR BENCHTOP GPO'S TO BE FIXED AT 300MM
ABOVE FFL. BENCH TOP GPO'S TO BE FIXED 300 ABOVE BENCHTOP.
PH
PH
PH
PH
PH
Scale Checked by
Drawn by
Date Project number
1 : 100
Electrical Plan
P1.0
FINCH STREET NEW DWELLING
MR A AND MRS M METCALF Issue Date
Author
HALEN MOKA
24 FINCH STREET, BEECHWORTH VIC W10
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
MASTER BEDROOM
ENSUITEWIR
DOUBLE GARAGE
STORAGE
LIVING KITCHEN
DINING
BATH
LAUNDRY
BED 2
STUDY
ROOF LINE
SL
SL
SL
SL
SL
SL
SL
LEGEND
SKYLIGHT
SMOKE ALARM
TYPE A
TYPE B
TYPE C
TYPE D
CEILING PITCH CHANGE
INDICTIVE LOCATION OF
MANHOLE
SL
PTY
WMDR
N
O
RTH
SL
SL
ROOF LINE
CEILINGPITCHCHANGE
CEILINGPITCHCHANGE
SMOKE DETECTORS TO BE IN ACCORDANCE WITH AS 3786-1993.
ALL ELECTRICAL WORKS AND INSTALLATION TO BE CONDUCTED BY A
REGISTERED ELECTRIAN AND IN ACCORDANCE WITH AS/NZS3000.
LIGHTING FIXTURES AND LOCATIONS MUST BE INSTALLED IN ACCORDANCE
WITH AS1680.
ALL INTERIOR LIGHTING MUST COMPLY WITH AS/NZS 1680.1 INTERIOR
LIGHTING PART 1 GENERAL PRINCIPLES.
ALL CEILINGS TO BE 13MM STANDARD CORE PLASTERBOARD.
CEILING MUST HAVE PEER 16X6000MM 0.38BMT DOMESTIC CEILING BATTEN
FCDB-60 @450 CNTRS INSTALLED TO MANUFACTURERES SPECS PRIOR
TO FIXING PLASTERBOARD. ALL PLASTERBOARD AND ITS RESPECTIVE
INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS.
SERVICES MUST BE IN PLACE BEFORE PLASTERBOARD INSTALLATION.
ENSURE FRAMING IS PLUMB, LEVEL &SQUARE AND THAT THE AREA IS
WEATHER PROOF. ENSURE THAT CEILING BATTEN SPACING TAKES INTO
ACCOUNT THE WIDTH OF PLASTERBOARD SHEETS AND ALLOWS FIXING
POINTS AT ITS EDGES. STANDARD CORE 13MM PLASTERBOARD TO BE
FIXED ALONG CEILING BATTENS AND 15MM FROM SHEET EDGES AND ENDS
WITH 30MM 'W' TYPE PLASTERBOARD SCREWS .
TYPE: A QUANTITY: 9
MINIWOODY LED 42W FACADE LAMP
LED SPOT LAMP FOR CEILING/WALL MOUNTED SPOT LIGHTING.
TYPE: B QUANTITY: 57
LEDLUX 14W 92MM NON-DIMMABLE CNC ALUMINIUM ROUND DOWN LIGHT.
CEILING MOUNTED DOWNLIGH FOR AMBIENT LIGHTING.
TYPE: C Quantity: 4
T5 STARCOAT 80W LINEAR FLUROSCENT LAMP FOR CEILING MOUNTED
GARAGE LIGHTS.
TYPE: D Quantity: 8
THERMALITE DELUXE 3 IN 1 BATHROOM HEATER 4X275W HEAT LAMPS.
STAINLESS STEEL HOUSING WITH BUILT IN EXHAUST AND HEAT LAMPS.
SMOKE ALARM TYPE:
WORMWALD TYCO 614P PHOTOELECTRIC SMOKE DETECTOR.
General Notes
ROOFLINE
FIXED CEILING LIGHTING TYPES
MH
MH
MH
MH
Scale Checked by
Drawn by
Date Project number
1 : 100
Reflected Ceiling Plan
P1.0
FINCH STREET NEW DWELLING
MR A AND MRS M METCALF Issue Date
Author
HALEN MOKA
24 FINCH STREET, BEECHWORTH VIC W11
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
MASTER BEDROOM
4m X 4.7m
CARPET
ENSUITE
4m X 3.4m
TILES
WIR
4m X 1.3m
CARPET
DOUBLE GARAGE
6.7m X 4.2m
CONCRETE
STORAGE
0.8m X 3.1m
CONCRETE
LIVING
7m X 4.3m
FLOORBOARDS
KITCHEN
7.2m X 5m
FLOORBOARDS
DINING
4.4m X 4.2m
FLOORBOARDS
BATH
1.9m X 4.7m
TILES
LAUNDRY
4.7m X 1.5m
TILES
BED 1
3.4m X 4.7m
CARPET
BED 2
4.3m X 4.7m
CARPET
STUDY
2.5m X 4.7m
FLOORBOARDS
100X25 TURPENTINE DECKING
INTERGRAIN REDWOOD 'NATURAL' STAIN
AND TO COMPLY WITH APPENDIX E OF AS 3959 2009.
24m
2
400
1190
950
950
650
2920
260 3120 260 1020 800 1935 400 1930 400 655 260
1640836021510
31510
11040
260 3120 260 7140 260
1530 5260
260 3990 250 1280 720 605 2550 600 795
1567036608830
5555252855251690140519517301720173065517303825525280525427552543653690760
2
1
FFL400
FFL1190
7180872
16503320
4385
915
900
3230
1205
2646
2965
1960
2195
1820 1755 1310
1
2
3
4
5
6
7
8
9
10
11
14
12
13
15
16
17
18
19
20
1
2
4
5
6
7
8
9
3016
UP
CONCRETE
FLOORING
POLISHED
FINISH
TILED
FLOORING
OVERHEAD ROOF LINE
SL
SL
SL
SL
SL
SL
SL
SL
SL
CW5
ST
RH
REF
PTY
DW
WMDR
N
O
RTH
1
W08
1
W09
2
W08
OVERHEADBEAM
STRUCTURAL
COLUMN
300MM PARTITION WALL
EJ EJ
POOL GATE TO OPEN
AWAY FROM POOL WITH
SELF CLOSING SAFETY LATCH
1500MM HIGH MIN.
OVERHEADWINDOW
9 10
12
GENERAL NOTES
DECKING NOTES: DECKING TO BE MADE OF 130X30 TURPENTINE DECKING WITH 3MM GAP AND FIXED
WITH 50MM SELF DRILLING STAINLESS STEEL SCREWS.
TIMBER POSTS TO BE 100X100 TURPENTINE POSTS ON 100MM GAL STIRRUPS WITH TERMITE CAPPING.
TURPENTINE DECKING TO BE STAINED WITH INTERGRAIN REDWOOD STAIN TO MANUFACTURERES
SPECIFICATIONS. DECKING MATERIAL AND INSTALLATION TO COMPLIE WITH THE REQUIREMENTS FOR
BAL12.5 AS STATED IN AS 3959.
STAIRS TO BE CONSTRUCTED FROM 20MPA CLASS 1 FINISH CONCRETE.
BRICK VENNER WALLS TO BE CONSTRUCTED IN ACCORDANCE WITH AS 3700-2001 Section 12
INTERIOR LINING OF ALL WALLS TO BE 13MM PLASTERBOARD NATURAL WHITE COLOUR. EXCLUDING
GARAGE INTERIOR WALLS. REFER TO MANUFACTURER FOR INSTALLATION AND W06 AND W07
INTERNAL CLADDING NOTES.
SMOKE ALARMS LOCATED AT THE FRONT END OF THE HALLWAY, THE END OF THE HALLWAY AND
NEAR THE DOOR TO THE GARAGE IN THE LIVING ROOM. EXACT POSITIONING TO COMPLY WITH BCA
CL: 3.7.2.3
DOWNPIPE SPECS ARE SHOWN IN DETAIL ON WO6 AND WO7 ELEVATIONS AND IN PLAN ON W05
ROOF PLAN.
ALL WINDOW AND DOOR SIZES ARE NOMINAL. SPECIFICATIONS ARE SHOWN ON W01 DOOR AND
WINDOW SCHEDULE.
REFER TO ENGINEERS SPECIFICATIONS FOR STEEL CONSRUCTION.
MECHANICAL VENTILATION TO COMPLY WITH AS1668.
CARPET AND TILES IS TO BE INSTALLED TO MANUFACTURERS SPECIFICATIONS.
INTERIOR WALLS ARE 90MM STUD WALLS EXCEPT FOR THE WALLS SEPERATING THE GARAGE
FROM THE LIVING ROOM AND HALLWAY. AND TO BE CONSTRUCTED IN ACCORDANCE WITH AS 1684.4.
ALL EXTERNAL WALLS ARE TO HAVE 10MM X 38MM THERMABLOK STRIPS INSTALLED ON THE
INTERNAL SIDE OF THE STUD UNDERNEATH THE 13MM PLASTERBOARD. REFER TO MANUFACTURERS
SPECS.
FOR EXTERIOR WALL EXTERNAL LININGS REFER TO W06 AND W07
FOR EXACT POSITIONING OF CABINETRY REFER TO W14 AND W15
CUSTOM WINDOWS ARE TO BE INSTALLED TO MANUFACTURERS SPECIFICATIONS AND IN
ACCORDANCE ITH AS 2047.
SANITARY COMPARTMENTS TO BE IN ACCORDANCE WITH B.C.A, DOOR TO BE EITHER REMOVABLE IF
LESS THAN 1200mm BETWEEN TOILET AND DOOR OR MUST OPEN OUTWARDS.
ALL FLOOR WET AREAS ARE TO BE PROVIDED WITH IMPERVIOUS COVERINGS EXCEPT FOR THE
KITCHEN. WALLS OF SHOWER AND AROUND BATH ARE TO BE IMPERVIOUS COVERINGS ALSO OR
TILES OR GLASS.
METER BOX TO BE INSTALLED:STAINLESS STEEL 18 POLE SINGLE PHASE METER BOX MODEL
RS4852 WIRE, HALF DUPLEX , ISOLATED.
GARAGE WALLS ARE 240MM FIRE RATED BRICK VENEER WALLS AND TO BE CONSTRUCED IN
ACCORDANCE WITH AS 3700 AND AS1684.4.
INTERNAL STAIRS AND FLOORBOARDS TO BE MADE OF CAMBIA AWA SHIPLAP 18MM TIMBER
FLOORING INSTALLED TO MANUF'S SPECS.
TIMBER DECKING TO BE 100X25 TURPENTINE DECKING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED
WITH 50MM GAL SELF DRILLING SCREWS AND TO COMPLY WITH APPENDIX E OF AS 3959 2009.
SWIMMING POOL TO BE SELECTED BY CLIENT AND INSTALLED BY CERIFIED POOL CONTRACTORS TO
THE APPROPRIATE AND REQUIRED SAFETY REGULATIONS.
LEGEND
SPOT ELEVATION
SKYLIGHT
SMOKE ALARM
EXHAUST FAN
DOWN PIPE
260MM BRICK VENEER WALL
325MM PRECAST CONCRETE WALL
90MM TIMBER STUD WALL
DOOR TAG
WINDOW TAG
CUSTOM WINDOW TAG
GLASS BALUSTRADE
1000
SL
PTY PANTRY
DW DISHWASHER
WM WASHING MACHINE
ST STOVE
REF REFRIDGERATOR
RH RANGEHOOD
METER BOX
EXPANSION JOINT
6
6
CW1
EJ
Scale Checked by
Drawn by
Date Project number
1 : 100
Floor Plan
P1.0
FINCH STREET NEW DWELLING
MR A AND MRS M METCALF Issue Date
Author
HALEN MOKA
24 FINCH STREET, BEECHWORTH VIC W12
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
GENERAL NOTES
LEGEND
GARAGE SLAB
LOWER SLAB SECTION
HIGHER SLAB SECTION
REBATE
RE-ENTRANT BARS
EDGE BEAMS
N
O
RTH
300X300 INTERNAL BEAMS TO CONTAIN 3-L11TM REINFORCMENT
STEEL 30MM FROM BOTTOM OF BEAM AND @ 6M MAX CTRS.
GARAGE SLAB FFL 8864
400X300 EXTERNAL EDGE BEAMS TO CONTAIN 3-L11TM
REINFORCEMENTMESH 30MM FROM BOTTOM OF BEAM.
CONCRETE MANUFACTURED MUST BE IN ACCORDANCE WITH
AS3700
3-L11TM RE-ENTRANT BARS MUST BE IMPLEMENTED INTO THE
SLAB @30MM OF THE TOP OF THE SLAB.
200MM OVERLAP MUST OCCUR WHERE HOUSE SLAB MEETS
THE LOWERGARAGE SLAB.
CONCRETE SLAB TO BE CONSTRUCTED IN ACCORDANCE WITH
AS2870 AND USING SL82 AS REINFORCEMENT MESH 30MM
FROM TOP.
FORMWORK FOR CONCRETE SLAB TO BE CONSTRUCTED IN
ACCORDANCE WITH AS3610 FORMWORK FOR CONCRETE.
SLAB MUST BE CURED FOR 7 DAYS AND APPROVED BY A
REGISTERED BUILDING SURVEYOR.
SOIL CLASSIFICATION IS: CLASS M
M RE-ENTRANT BARS AT INTERNAL CORNERS
OF THE SLAB IN ACCORDANCE WITH BCA CL 3.2.5.3
NTERNAL REINFORCED
CONCRETE BEAM
300X300
EXTERNAL REINFORCED
CONCRETE EDGE BEAM
400X300
SLAB STEP DOWN OF
250MM REFER TO
DETAIL
400
GARAGE SLAB
650
1180
STEP DOWN OF125MM
REFER TO DETAIL
150MM REBATE TO
ALLOW FOR BRICK
VENEER CONSTRUCTION
Scale Checked by
Drawn by
Date Project number
1 : 100
Slab Plan
P1.0
FINCH STREET NEW DWELLING
MR A AND MRS M METCALF Issue Date
Author
HALEN MOKA
24 FINCH STREET, BEECHWORTH VIC W13
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
. .600
942
1190
1206 710 710 710 710
1414262
981 1190
1206
SB
RH
ST
1
W14
3
W14
4
W14
REF
OV
PTY
1206
3024
571
3418
2646772
53417451203902422466
12701162
3251 669914
610330321725
9097
2197 132
485
4
9
8
130x14MM SPOTTED GUM OVERLAY
FLOORBOARDS
DW
SHELVING
WINERACKS
772 447 1143 1295 92 1203 1745 515
295 525 399 2441 90 1343 525 278 525 812
320
1174 806 1894 806 2545
1190 1070
OV
REF
ST
RH
SK
14491526
9 8
4
1417762442
914914914
914
1190 1190 1190
253 1190 1190 589
SBSK
PB
STACKABLE
MAGNUM
WINERACKS
Scale Checked by
Drawn by
Date Project number
As indicated
Internal Elevations
P1.0
FINCH STREET NEW DWELLING
MR A AND MRS M METCALF Issue Date
Author
HALEN MOKA
24 FINCH STREET, BEECHWORTH VIC W14
1 : 50
Section 6
1
1 : 50
Internal Plan Kitchen
2
1 : 50
Section 7
3 1 : 50
Section 8
4
KITCHEN INTERNAL ELEVATIONS
KITCHEN INTERNAL PLAN
SKYLIGHTS: SKYDOME VELUX/VSE LOW E DOUBLE GLAZED
BLACK ALUMINIUM FRAME INSTALLED, SEALED AND
WATERPROOFED TO MANUFACTURERES SPECS.
SPLASHBACK: DARK SLATE GLASS SPLASHBACK
RANGEHOOD 24" ISLAND RANGEHOOD STAINLESS STEEL ROUND CHIMNEY KA-123-
CS.
KITCHEN WALL X8 KABOODLE 1200MM 2 DOOR WHITE WALL HUNG CABINET.
HUNG CABINETS: W/SILVER ANODISED ALUMINIUM 'G' STYLE GRIP HANDLES.
KITCHEN BASE X3 KABOODLE 710MM 4 DRAWER WHITE BASE CABINET
CABINETS: X3 KABOODLE 710MM 3 DRAWER WHITE BASE CABINET
W/SILVER ANODISED ALUMINIUM 'G' STYLE GRIP HANDLES.
19MM MOISTURE RESISTANT NATURAL WHITE MELAMINE
PARTICLE BOARD WITH HIGH GLOSS FINISH.
ENSURE CABINETRY IS FIXED AND LEVELED TO PREVENT
DOORS FROM SWINGING OPEN UNINTENTIONALLY AND TO
CREATE AN EVEN FIX WITH THE COUNTERTOP.
ALL WALL HUNG CABINETS MUST BE FIXED USING THE
PROVIDED WALL ANCHORS AND SCREWS TO THE WALL
STUDS.
REFRIDGERATOR: JENN-AIR 25.02 CU. FT. SIDE-BY-SIDE REFRIDGERATOR
STAINLESS STEEL.
OVEN: KITCHENAID 30" SINGLE ELECTRIC WALL OVEN
STAINLESS STEEL.
MUST BE INSTALLED BY CERTIFIED ELECTRICIAN.
PANTRY 1300MM BEDFORD 2 DOOR WHITE FREESTANDING PANTRY
MUST BE INSTALLED TO MANUFACTURERES SPECIFICATIONS
FLOORBOARDS: 130X14MM NSW SPOTTED GUM CLASS 1 DURABILITY
FLOORBOARDS.
DURBAILITY: CLASS 1
GRADE: STANDARD AND BETTER
COLOUR: WARM
LENGTHS: RANDOM LENGTHS OF 0.4M-2.4M.
NOTES: FLOORBOARDS TO BE GLUED OVER 19MM PARTICAL BOARD
SUBFLOOR
CEASAR STONE:. KITCHEN COUNTERTOP TO BE OSPREY CEASERSTONE W/PENCIL
ROUNDED EDGES.
KITCHEN TAP: X2 GESSI OXYGENE PULL OUT SPRAY KITCHEN MIXER BLACK SPOUT
KITCHEN SINK: X2 SCHOCK STONE DOUBLE BOWL UNDERMOUNT KITCHEN SINK
BLACK.
COOKTOP: KITCHENAID 40" GAS COOKTOP- STAINLESS STEEL
MUST BE INSTALLED BY CERTIFIED ELECTRICIAN..
SHELVING: CHICAGO 8 BOX 1200MM TIMBER SHELVING BY BLUE DOT.
INSTALLED TO MANUFACTURERES SPECIFICATIONS.
DISHWASHER: TO BE SELECTED BY CLIENT
INSTALLED BY CERTIFIED PLUMBER
OVEN AND COOKTOP TO BE CONNECTED AND
INSTALLED BY A REGISTERED ELECTRICIAN TO
MANUFACTURERES SPECIFICATIONS.
DISHWASHER, BASINS AND TAPWARE TO BE
INSTALLED BY REGISTERED PLUMBER.
WINERACKS ARE FREE STANDING AND STACKABLE
AND ARE NOT TO BE FIXED TO EACHOTHER, THE
FLOOR OR THE WALL.
SHELVING TO BE SINTALLED TO MANUFACTURERES
SPECIFICATIONS.
ALL WALLS TO BE PAINTED WITH DULUX NATURAL
WHITE PAINT.
DURING INSTALLATION OF SPLASHBACK THE SURFACE
AREA MUST BE CLEAN AND ALL WALL FIXINGS MUST
BE FLUSH OR RECESSED INTO THE WALL., A 6MM
GAP MUST BE LEFT WHERE PANELS MEET AT ANY
CORNERS AND AT EACH END. A 3MM GAP MUST ALSO
BE LEFT WHERE PANELS MEET AND WHERE THE
PANEL ABUTTS OVERHEAD CUPBOARDS OR WINDOW
OPENINGS. ENSURE THE WALL IS PAINTED THE SAME
COLOUR AS THE PANEL WHERE SHEETS MEET. PANEL
MUST BE FIXED WITH DOUBLE SIDED TAPE AND A
6MM BEAD OF ADHESIVE APPLIED IN A WAVE
FORMATION ON THE UNDERSIDE OF THE PANEL.
EDGES WHERE COUNTERTOP MEETS SPLASHBACK
AND AROUND KITCHEN BASIN TO BE SEALED AND
WATERPROOFED.
90MM PARTITION WALL PAINTED
NATURAL WHITE
CEASERSTONE COUNTERTOP
6MM OSPREY CEASERSTONE COUNTERTOP
WITH ROUNDED PENCIL EDGES
CEASERSTONE COUNTERTOP MUST BE FIXED TO A LEVEL
SURFACE AND GLUED TO THE KITCHEN BASE CABINETS
AND PROTECTED DURING THROUGHOUT THE
CONSTRUCTION..
SERVICES MUST BE IN PLACE BEFORE INSTALLATION.
ENSURE FRAMING IS PLUMB, LEVEL &SQUARE AND THAT
THE AREA IS WEATHER PROOF. ENSURE THAT STUD
SPACING TAKES INTO ACCOUNT THE WIDTH OF
PLASTERBOARD SHEETS AND ALLOWS FIXING POINTS AT
ITS EDGES. STANDARD CORE 13MM PLASTERBOARD TO BE
FIXED ALONG WALLS STUDS AND 15MM FROM SHEET
EDGES AND ENDS WITH 30MM 'W' TYPE PLASTERBOARD
SCREWS.
ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION
MUST COMPLY WITH AS2589-GYPSUM LININGS.
OV KITCHENAID 30" SINGLE ELECTRIC WALL OVEN
PTY PANTRY
SB SPLASHBACK
DW DISHWASER TO BE SELECTED BY CLIENT
RH 24" ISLAND ROUND CHIMNEY RANGEHOOD KA-123-CS.
ST KITCHENAID 40" GAS COOKTOP
REF JENN-AIR 25.02 SIDE-BY-SIDE REFRIDGERATOR
SK SCHOCK STONE DOUBLE BOWL KITCHEN SINK
LEGEND
GENERAL NOTES
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
10001440
749 450 157 1600 1899
1093
13MM PLASTERBOARD
100X300 MANHATTAN TILE
MR
VN SH
BT
TL
172X600MM INSUDTRIE
MOSAIC SATIN TILE
1045 90 765
283
VN
BT
SH
2 13MM PLASTERBOARD
100X300 MANHATTAN TILE
172X600MM INSUDTRIE
MOSAIC SATIN TILE
SHOWER PANEL
1525901050
3822
8931007
1381 1600 1899
1
W15
1125
1057
2
W15
SK
VN
SH
2
250X250 ECO TILES
5
W15
1606 691 933
11009020015201801000
900 2330
SH
SK
VN
BT
TL
250X250 ECO TILES
1100 90160 1600 160 980
2400519
1000
MR
VN
TL
SH
100X300 MANHATTAN TILE
SHOWER PANEL
172X600 INDUSTRIE
MOSAIC TILE
PB
7
W15
8
W15
2180 1461
670
273 915 273
1421
2060
1412 1449 2000
2820
SK
DR WM BASE CABINETS
250X250 ECO TILES
7801821
1000 1000
180 1000 1000 288 2412
180
0811
11 16
250X250
ECO TILES
PB
PB
3450 90 1315
80790200
1000 1000
DRWM
PB
PARTITION WALL
250X250 ECO TILES
16
1420
Scale Checked by
Drawn by
Date Project number
As indicated
Internal Elevations II
P1.0
FINCH STREET NEW DWELLING
MR A AND MRS M METCALF Issue Date
Author
HALEN MOKA
24 FINCH STREET, BEECHWORTH VIC W15
1 : 50
Section 9
1 1 : 50
Section 10
2
1 : 50
Internal Plan Bathroom
3
1 : 50
Internal Plan Ensuite
4
1 : 50
Section 13
5
1 : 50
Internal Plan Laundry
6 1 : 50
Section 11
7 1 : 50
Section 12
8
BATH LUNA STONE BATH 1680 W. LUNA WHITE HEADREST
BASIN VISTA SAVANNA SEMI-RECESSED BASIN
MIRROR FORME MIRROR MLD 1200
SHOWER HEAD SENNA STAINLESS STEEL WALL FIXED SHOWER HEAD
BATHROOM SINK RUSH STAINLESS STEEL WALL BASIN 3 PEICE OUTLET SET
TAPS
BATH SPOUT RUSH WALL MOUNTED STAINLESS STEEL BATH SPOUT 3 PEICE SET
TILES: ECO ALABLASTER GRIGIO LAPPATO BEAUMON TILES (FLOOR)
MANHATTAN TAUPE MATTE DECOR 100X300 TILES (WALL)
INDUSTRIE MOSAIC SATIN 172X600MM SHEET (STONE FEATURE)
BATHROOM GATEWAY 1200 WALL HUNG VANITY WITH CEASERSTONE TOP
VANITY
TOILET LUCCA LOSE COUPLED TOILET SUITE
SHOWER BASE 1050X1520MM LUNA SHOWER BASE W/ REAR WASTE DRAIN
BATHROOM
LAUNDRY
ENSUITE
BASIN CLARK 45L FLUSHLINE STANDARD SINGLE
STAINLESS STEEL LAUNDRY BASIN.
SINK TAPS MONDELLA WELS 4 STAR 7L/MIN SIDE LEVER CURVED
STAINLESS STEEL BASIN MIXER.
TILES: ECO ALABLASTER GRIGIO LAPPATO BEAUMON TILES
LAUNDRY BEFORD 1000MM WHITE 2 DOOR BASE CABINET
CUPBOARDS W/CEASER STONE TOP AND KABOODLE URBAN OAK
MODERN VENEER FINISH X4
BEFORD 1000MM WHITE 2 DOOR WALL UNIT
W/ KABOODLE URBAN OAK MODERN VENEER FINISH X2
W/SILVER ANODISED ALUMINIUM 'G' STYLE GRIP HANDLES.
19MM MOISTURE RESISTANT NATURAL WHITE MELAMINE
PARTICLE BOARD WITH HIGH GLOSS FINISH.
ENSURE CABINETRY IS FIXED AND LEVELED.
ALL WALL HUNG CABINETS MUST BE FIXED USING THE
PROVIDED WALL ANCHORS AND SCREWS TO THE WALL STUDS.
WASHING MACHINE: TO BE SELECTED BY CLIENT
DRYER: TO BE SELECTED BY CLIENT
BATH LUNA STONE BATH 1680 W. LUNA WHITE HEADREST
BASIN VISTA SAVANNA SEMI-RECESSED BASIN
MIRROR FORME MIRROR MLD 1200
SHOWER HEAD SENNA STAINLESS STEEL WALL FIXED SHOWER HEAD
BASIN TAPS RUSH STAINLESS STEEL WALL BASIN 3 PEICE OUTLET SET
BATH SPOUT VIVID FLOOR MOUNTED STAINLESS STEEL BATH SPOUT
W/RUSH STAINLESS STEEL WALL MOUNTED TAPS.
TILES: ECO ALABLASTER GRIGIO LAPPATO BEAUMON TILES (FLOOR)
MANHATTAN TAUPE MATTE DECOR 100X300 TILES (WALL)
INDUSTRIE MOSAIC SATIN 172X600MM SHEET (STONE FEATURE)
BATHROOM GATEWAY 1200 WALL HUNG VANITY WITH CEASERSTONE TOP
VANITY W/SILVER ANODISED ALUMINIUM 'G' STYLE GRIP HANDLES.
19MM MOISTURE RESISTANT NATURAL WHITE MELAMINE
PARTICLE BOARD WITH HIGH GLOSS FINISH.
ENSURE CABINETRY IS FIXED AND LEVELED TO PREVENT
DOORS FROM SWINGING OPEN UNINTENTIONALLY AND TO
CREATE AN EVEN FIX WITH THE COUNTERTOP.
TOILET LUCCA LOSE COUPLED TOILET SUITE
SHOWER BASE 1000X1600MM LUNA SHOWER BASE W/ REAR WASTE DRAIN
BUILDER TO INSTALL TO MANUFACTURERES SPECS.
GENERAL NOTES
ALL CUPBOARDS AND VANITIES ARE TO BE
ASSEMBLED AND INSTALLED INACCORDANCE WITH THE
MANUFACTURERS SPECIFICATIONS.
ALL TAPWARE, SHOWERHEADS, TOILETS AND BASINS
TO BE INSTALLED BY CERTIFIED PLUMBER.
GLASS SHOWER PANELS ARE TO BE INSTALLED TO
MANUFACTURERS SPECIFICATIONS AFTER SHOWER
BASE HAS BEEN INSTALLED, WATER-PROOFED AND
TESTED FOR LEAKAGE. SHOWER BASE TO BE
INSTALLED TO MANUFACTUERES SPECIFICATIONS.
ALL TILEED AREAD MUST BE WATERPROOFED AND BE
FIXED BY A PROFESSIONAL TILER. SEE W13 FOR
WATERPROOFING OF WET AREAS DETAIL.
SERVICES MUST BE IN PLACE BEFORE INSTALLATION.
ENSURE FRAMING IS PLUMB, LEVEL &SQUARE AND
THAT THE AREA IS WEATHER PROOF. ENSURE THAT
STUD SPACING TAKES INTO ACCOUNT THE WIDTH OF
PLASTERBOARD SHEETS AND ALLOWS FIXING POINTS
AT ITS EDGES. STANDARD CORE 13MM PLASTERBOARD
TO BE FIXED ALONG WALLS STUDS AND 15MM FROM
SHEET EDGES AND ENDS WITH 30MM 'W' TYPE
PLASTERBOARD SCREWS.
CEILING MUST HAVE PEER 16X6000MM 0.38BMT
DOMESTIC CEILING BATTEN FCDB-60 @450 CNTRS
INSTALLED TO MANUFACTURERES SPECS PRIOR TO
FIXING PLASTERBOARD. ALL PLASTERBOARD AND ITS
RESPECTIVE INSALLATION MUST COMPLY WITH AS2589-
GYPSUM LININGS.
PB 13MM STANDARD CORE PLASTERBOARD
WM WASHING MACHINE
DR DRYER
MR MIRROR
VN VANITY
TL TOILET
BT BATH
LEGEND
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
9MM TOUGHENED SAFETY GLASS
13X90 TURPENTINE DECKING
FIXED W/ 50MM SELF DRTILLING
DECKING SCREWS
PREMIUM FLANGED ROUND SPIGOT.
150MM CNC-MACHINED FROM 316
MARINE GRADE STAINLESS STEEL
BILLET, W/6MM SOLID PLATEPRESS
FITTED AND WELDED. FIXED TO
MANUFS SPECIFICATIONS.
90MM GAL STEEL STIRRUP
2X90X45 MGP10 TIMBER DECKING JOISTS
DOOR
CERAMIC TILES CARPET
FLOORING
IN-SITU PERIMETER
FLASHING
BRASS OR ALUMINIUM ANGLE
90MM STUD WALL CERAMIC WALL TILES
VILLABOARD
LINING
INTERNAL IN-SITU FLASHING
FLEXIBLE WET AREA SEALANT
FLOOR TILES
MORTAR BED
FLOORING
SUITABLE TAPE
FLOOR JOIST
GALVANISED STIRUP IN 20MPA
CONRETE 60MM STUMP
SLIDING DOOR
TIMBER DECKING 90X13 TURPENTINE FIXED WITH
50MM GALV. SELF DRILLING DECKING SCREWS
W/10MM GAP BETWEEN DECKING AND BUILDING
TO ALLOW FOR MOVEMENT. CONSTRUCTION AND
FIXING TO COMPLY WITH BAL 12.5.
2X90X45 F8 SEASONED TURPENTINE FIXED WITH
M12 GALV. BOLT-NUT-WASHER. W/45X90MM RECESS
FOR BEARER.
BEAER 2/90X45 TURPENTINE
100MM 20MPA
CONCRETE SLAB
3-L11TM MESH REINFORCEMENT
FLOORBOARDS
MIN150
10MM BLUE BOARD SHEETING. TOP
FIXED WITH 50MM BATTEN SCREWS
AND HELD BEHIND TURPENTINE EDGE
DECKING. THE OTHER END MUST BE
PARTIALLY EMBEDDED INTO THE
GROUND A MINIMUM OF 150MM.
MIN150
ENSURE THAT STUD SPACING TAKES INTO
ACCOUNT THE WIDTH OF PLASTERBOARD
SHEETS AND ALLOWS FIXING POINTS AT ITS
EDGES. STANDARD CORE 13MM
PLASTERBOARD TO BE FIXED ALONG WALLS
STUDS AND 15MM FROM SHEET EDGES AND
ENDS WITH 30MM 'W' TYPE PLASTERBOARD
SCREWS. ALL PLASTERBOARD AND ITS
RESPECTIVE INSALLATION MUST COMPLY
WITH AS2589-GYPSUM LININGS.
R2.7 HIGH PERFORMANCE GOLD BRADFORD
INSULATION BATTS
1160X580 CUT TO FIT SECURED WITH 13MM
STANDARD CORE PLASTERBOARD.
90X45 MGP10 BOTTOM PLATE
FIXED WITH BOLT DYNABOLT 12X100MM
HEX NUT EA
2X90X45 MGP10 TOP PLATE
FIXED TO TIMBER STUD WALL WITH
100X2.8MM BRIGHT 'D' HEAD
MACHINE DRIVEN NAILS
COLORBOND® STEEL CONFORMING TO AS 1397-G550-
AM100 AND AS 2728.
COLOUR: MONUMENT 0.42 BMT
FASTENERS SHOULD BE SELECTED TO MATCH THE
GRADE OF THE ROOFING MATERIAL.
SIZE: AS PER ROOF SIZE.
SPACING: 1200MM
THE ROOF SHEETING AND ACCESSORIES SHALL BE
INSTALLED IN ACCORDANCE WITH MANUFACTURER
SPECIFICATIONS.
90MM COLOURBOND LYSAGHT
QUAD GUTTER 'MONUMENT'
FIXED TO MANUFACTURERES SPECS
DN 90 TYPE C METAL DOWNPIPE
'MONUMENT' LOW GLOSS FINISH
220mm X 140mm METAL RAINWATER HEAD
FIXED TO CLADDING USING
MANUFACTURERS SPEC
200X38MM TURPENTINE FASCIA BOARD
FIXED 100X2.8MM BRIGHT 'D' HEAD
MACHINE DRIVEN NAILS
CEILING MUST HAVE PEER
16X6000MM 0.38BMT
DOMESTIC CEILING BATTEN
FCDB-60 @450 CNTRS
INSTALLED TO
MANUFACTURERES SPECS
PRIOR TO FIXING
PLASTERBOARD. ALL
PLASTERBOARD AND ITS
RESPECTIVE INSALLATION
MUST COMPLY WITH
AS2589-GYPSUM LININGS.
100X25 TURPENTINE CLADDING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED WITH 50MM
GAL CLOUTS END GRAIN TO BE SEALED
AND INTERGRAIN REDWOOD STAIN
TO BE APPLIED TO CLADDING
AS PER MANUFACTURERES SPECS.
WALL MUST BE SARKED WITH AMETALIN
SILVERWRAP FOIL INSULATION AND
EXTERNALLY FIXED WITH 6MM CEMENT
SHEETING USING 30MM GAL CLOUTS.
50X50 HORIZONTAL BATTENS TO BE
FIXED TO VERTICAL BATTENS AT 600
CNTRS WITH 65MM BATTEN SCREWS.
600
0.2MM POLYETHELYNE VAPOUR BARRIER
400X300 EXTERNAL EDGE BEAMS TO
CONTAIN 3-L11TM REINFORCEMENTMESH
30MM FROM BOTTOM OF BEAM.
72
90X45 MGP10 NOGGIN
TWO NOGGINS ARE TO BE PLACED BETWEEN EACH
TIMBER STUD. ONE @900MM AND ONE @1800MM
UP THE HEIGHT OF THE WALL.
FIXED TO TIMBER STUD WALL WITH
100X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS
200X125MM STEEL RHS INSTALLED AND FIXED
TO ENGINEERS SPECIFICATIONS.
COLORBOND® STEEL CONFORMING TO AS
1397-G550-AM100 AND AS 2728.
COLOUR: MONUMENT 0.42 BMT
FASTENERS SHOULD BE SELECTED TO
MATCH THE GRADE OF THE ROOFING
MATERIAL.
SIZE: AS PER ROOF SIZE.
SPACING: 1200MM
THE ROOF SHEETING AND ACCESSORIES
SHALL BE INSTALLED IN ACCORDANCE
WITH MANUFACTURER SPECIFICATIONS.
CEILING MUST HAVE PEER 16X6000MM 0.38BMT DOMESTIC
CEILING BATTEN FCDB-60 @450 CNTRS INSTALLED TO
MANUFACTURERES SPECS PRIOR TO FIXING
PLASTERBOARD. ALL PLASTERBOARD AND ITS RESPECTIVE
INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS.
R2.7 HIGH PERFORMANCE GOLD
BRADFORD INSULATION BATTS
1160X580 CUT TO FIT SECURED WITH 13MM
STANDARD CORE PLASTERBOARD.ENSURE THAT STUD SPACING
TAKES INTO ACCOUNT THE
WIDTH OF PLASTERBOARD
SHEETS AND ALLOWS FIXING
POINTS AT ITS EDGES.
STANDARD CORE 13MM
PLASTERBOARD TO BE FIXED
ALONG WALLS STUDS AND
15MM FROM SHEET EDGES
AND ENDS WITH 30MM 'W'
TYPE PLASTERBOARD
SCREWS. ALL PLASTERBOARD
AND ITS RESPECTIVE
INSALLATION MUST COMPLY
WITH AS2589-GYPSUM LININGS.
180X90 MGP10 RAFTER
100X250 GAL NAIL PLATE
152.00°
7.00°
90.00°
55.00°
13MM STANDARD CORE PLASTERBOARD BULKHEAD
125.00°
83.00°
260
151
151
180X45 MGP10 RAFTER
FIXED WITH 100X2.8MM
BRIGHT 'D' HEAD
MACHINE DRIVEN NAILS
CEILING MUST HAVE PEER 16X6000MM
0.38BMT DOMESTIC CEILING BATTEN
FCDB-60 @450 CNTRS INSTALLED TO
MANUFACTURERES SPECS PRIOR TO
FIXING PLASTERBOARD. ALL
PLASTERBOARD AND ITS RESPECTIVE
INSALLATION MUST COMPLY WITH
AS2589-GYPSUM LININGS.
VELUX DECK SEAL
COLORBOND® STEEL CONFORMING TO AS 1397-G550-
AM100 AND AS 2728.
COLOUR: MONUMENT 0.42 BMT
FASTENERS SHOULD BE SELECTED TO MATCH THE
GRADE OF THE ROOFING MATERIAL.
SIZE: AS PER ROOF SIZE.
SPACING: 1200MM
THE ROOF SHEETING AND ACCESSORIES SHALL BE
INSTALLED IN ACCORDANCE WITH MANUFACTURER
SPECIFICATIONS.
30-60
35X90 MGP10 ROOF BATTEN
OUTSIDE FRAME WIDTH
VELUX MIDDLE GUTTER
WITH VELUX FLASHING
VELUX VS/E VELUX VS/E
R2.7 HIGH PERFORMANCE GOLD
BRADFORD INSULATION BATTS
1160X580 CUT TO FIT SECURED
WITH 13MM STANDARD CORE
PLASTERBOARD.
VELUX EKW FLASHING GUTTER
THERMOSEAL SARKING
180X45 MGP10 RAFTER
FIXED WITH 100X2.8MM BRIGHT 'D' HEAD
MACHINE DRIVEN NAILS
CEILING MUST HAVE PEER 16X6000MM 0.38BMT
DOMESTIC CEILING BATTEN FCDB-60 @450
CNTRS INSTALLED TO MANUFACTURERES
SPECS PRIOR TO FIXING PLASTERBOARD. ALL
PLASTERBOARD AND ITS RESPECTIVE
INSALLATION MUST COMPLY WITH AS2589-
GYPSUM LININGS.
VELUX DECK SEAL
COLORBOND® STEEL CONFORMING TO AS 1397-G550-AM100 AND AS
2728.
COLOUR: MONUMENT 0.42 BMT
FASTENERS SHOULD BE SELECTED TO MATCH THE GRADE OF THE
ROOFING MATERIAL.
SIZE: AS PER ROOF SIZE.
SPACING: 1200MM
THE ROOF SHEETING AND ACCESSORIES SHALL BE INSTALLED IN
ACCORDANCE WITH MANUFACTURER SPECIFICATIONS.
35X90 MGP10 ROOF BATTEN VELUX
VS/E
R2.7 HIGH PERFORMANCE GOLD
BRADFORD INSULATION BATTS
1160X580 CUT TO FIT SECURED
WITH 13MM STANDARD CORE
PLASTERBOARD.
THERMOSEAL WATERPROOF
SARKING
100
M
IN
Scale Checked by
Drawn by
Date Project number
As indicated
Details
P1.0
FINCH STREET NEW DWELLING
MR A AND MRS M METCALF Issue Date
Author
HALEN MOKA
24 FINCH STREET, BEECHWORTH VIC W16
1 : 5
Balustrade detail
1
1 : 10
Typical Wet Areas
4
1 : 10
Decking Construction
31 : 10
Brick Veneer Section Detail
2
1 : 10
Roof Pitch Change
6
1 : 10
Horizontal Skylight Section
7
1 : 10
Vertical Skylight section
8
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
ENSURE THAT STUD SPACING TAKES INTO ACCOUNT
THE WIDTH OF PLASTERBOARD SHEETS AND
ALLOWS FIXING POINTS AT ITS EDGES. STANDARD
CORE 13MM PLASTERBOARD TO BE FIXED ALONG
WALLS STUDS AND 15MM FROM SHEET EDGES AND
ENDS WITH 30MM 'W' TYPE PLASTERBOARD
SCREWS. ALL PLASTERBOARD AND ITS RESPECTIVE
INSALLATION MUST COMPLY WITH AS2589-GYPSUM
LININGS.
R2.7 HIGH PERFORMANCE GOLD
BRADFORD INSULATION BATTS
1160X580 CUT TO FIT SECURED WITH 13MM
STANDARD CORE PLASTERBOARD.
90X45 MGP10 BOTTOM PLATE
FIXED WITH BOLT DYNABOLT 12X100MM
HEX NUT EA
2X90X45 MGP10 TOP PLATE
FIXED TO TIMBER STUD WALL WITH
100X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS
COLORBOND® STEEL CONFORMING TO AS 1397-
G550-AM100 AND AS 2728.
COLOUR: MONUMENT 0.42 BMT
FASTENERS SHOULD BE SELECTED TO MATCH THE
GRADE OF THE ROOFING MATERIAL.
SIZE: AS PER ROOF SIZE.
SPACING: 1200MM
THE ROOF SHEETING AND ACCESSORIES SHALL BE
INSTALLED IN ACCORDANCE WITH MANUFACTURER
SPECIFICATIONS.
90MM COLOURBOND LYSAGHT
QUAD GUTTER 'MONUMENT'
FIXED TO MANUFACTURERES SPECS
DN 90 TYPE C METAL DOWNPIPE
'MONUMENT' LOW GLOSS FINISH
220mm X 140mm METAL RAINWATER
HEAD FIXED TO CLADDING USING
MANUFACTURERS SPEC
200X38MM TURPENTINE FASCIA BOARD
FIXED 100X2.8MM BRIGHT 'D' HEAD
MACHINE DRIVEN NAILS
CEILING MUST HAVE PEER 16X6000MM 0.38BMT DOMESTIC
CEILING BATTEN FCDB-60 @450 CNTRS INSTALLED TO
MANUFACTURERES SPECS PRIOR TO FIXING
PLASTERBOARD. ALL PLASTERBOARD AND ITS RESPECTIVE
INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS.
100X25 TURPENTINE CLADDING
INTERGRAIN REDWOOD
'NATURAL' STAIN FIXED WITH 50MM
GAL CLOUTS END GRAIN TO BE SEALED
AND INTERGRAIN REDWOOD STAIN
TO BE APPLIED TO CLADDING
AS PER MANUFACTURERES SPECS.
WALL MUST BE SARKED WITH AMETALIN
SILVERWRAP FOIL INSULATION AND
EXTERNALLY FIXED WITH 6MM CEMENT
SHEETING USING 30MM GAL CLOUTS.
50X50 HORIZONTAL BATTENS TO BE
FIXED TO VERTICAL BATTENS AT 600
CNTRS WITH 65MM BATTEN SCREWS.
200
12
15
600
0.2MM POLYETHELYNE VAPOUR BARRIER
400X300 EXTERNAL EDGE BEAMS TO CONTAIN 3-
L11TM REINFORCEMENTMESH 30MM FROM BOTTOM
OF BEAM.
0.2MM POLYETHELYNE VAPOUR BARRIER
SL82 SLAB REINFORCEMENT
MESH
150MM 25MPA CONCRETE SLAB
250MM BRICK VENEER WALL
90X45 MGP10 BOTTOM PLATE
FIXED WITH BOLT DYNABOLT 12X100MM
HEX NUT EA
250
ENSURE THAT STUD SPACING TAKES INTO ACCOUNT
THE WIDTH OF PLASTERBOARD SHEETS AND
ALLOWS FIXING POINTS AT ITS EDGES. STANDARD
CORE 13MM PLASTERBOARD TO BE FIXED ALONG
WALLS STUDS AND 15MM FROM SHEET EDGES AND
ENDS WITH 30MM 'W' TYPE PLASTERBOARD
SCREWS. ALL PLASTERBOARD AND ITS RESPECTIVE
INSALLATION MUST COMPLY WITH AS2589-GYPSUM
LININGS.
300X300 INTERNAL BEAMS TO CONTAIN 3-L11TM
REINFORCMENT STEEL 30MM FROM BOTTOM OF
BEAM AND @ 6M MAX CTRS.
GARAGE SLAB FFL 8864
SAND
FILTERWRAP GEOFABRIC
FREE DRAINING
GRANULAR FILL
AGGREGATION PIPE TO BE VINIDEX
100MM X 20M SLOTTED DRAINCOIL
AND INSTALLED BELOW AND BEHIND
THE RETAINING WALL ABOVE GEO
FABRIC AND COVERED IN CORSE
GRANULAR FILL. GEO FABRIC MUST
BE USED TO SEPERATE THE
GRANULAR FILL AND SOIL BEHIND
THE RETAINING WALL.
4X110X220 TREATED PINE SLEEPERS
FIXED AT THE TOP AT EACH END
OF EACH SLEEPER WITH A 65MM BATTEN
SCREW. A HOLE MUST BE DRILLED THROUGH
THE STEEL COLUMN FIRST.
120MM GALVANISED STEEL 'I'
BEAM CHANNEL
EARTH
300X300 20MPA
CONCRETE FOOTING
20X150 MGP10 TOP TIMBER COVER TO BE
FIXED WITH 65MM BATTEN SCREW
0.2 POLYETHYLENE VAPOUR
BARRIER MUST BE USED TO
DIRECT WATER BUILDUP TO
THE AGGREGATION PIPE AND
PREVENT WATER FROM
TRANSFERRING THROUGH THE
WALL
EARTH
Scale Checked by
Drawn by
Date Project number
As indicated
Details II
P1.0
FINCH STREET NEW DWELLING
MR A AND MRS M METCALF Issue Date
Author
HALEN MOKA
24 FINCH STREET, BEECHWORTH VIC W17
1 : 10
Timber wall Section
2
1 : 10
Slab Step down detail
3
1 : 10
Retaining wall
4
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT
PRODUCEDBYANAUTODESKSTUDENTPRODUCT

24 Finch St Working Drawings

  • 1.
    1 MASTER ANGLEDTOP 430 3700 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON Mark Location Window Style Width Height Material Glazing Remarks Custom Window Schedule(All windows to be supplied by Stegbar) 2 MASTER ANGLED TOP 430 5720 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON 3 ENTRY RECTANGLE 640 140 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON 7 LIVING PARALLELOGRAM 2970 335 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON 10 DINING RIGHT ANGLE 3975 505 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON 4 ENTRY RECTANGLE 640 140 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON 5 ENTRY RECTANGLE 640 140 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON 6 ENTRY RECTANGLE 640 140 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON 8 STUDY ANGLED TOP 560 5000 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON 9 STUDY ANGLED TOP 560 3480 ALUMINIUM DBL 9MM TOUGHENED THERMALLY BROKEN W/ARGON AWNING AWNING AWNING AWNING AWNING AWNING AWNING AWNING AWNING FIXED CUSTOM WINDOWS WINDOW SCHEDULE DOOR SCHEDULEgeneral notes N1 USE WRITTEN DIMENSIONS WHERE GIVEN OVER SCALE N2 THESE PLANS ARE TO BE READ IN CONJUNCTION WITH ANY STRUCTURAL OR ENGINEERING DRAWINGS AND ASSOCIATED TOWN PLANNING PERMITS AND DRAWINGS. N3 SMOKE ALARMS TO BE INSTALLED IN ACCORDANCE WITH AS 3786 AND BE HARDWIRED WITH A BATTERY BACK-UP. N4 ALL WET AREAS TO COMPLY WITH BCA 3.8.1 OR AS 3740 - WALL FINISHEES SHALL BE IMPERVIOUS TO A HEIGHT OF 1800MM ABOVE FLOOR LEVEL TO SHOWER ENCLOSURES AND 15MM ABOVE BATHS, BASINS, SINKS AND TROUGHS IF WITHIN 75MM OF THE WALL. N5 CONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS, SETBACKS AND SPECIFICATIONS PRIOR TO COMMENCING ANY WORKS OR ORDERING MATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKS CONFORM TO THE BCA, A.S CODES CURRENT EDITIONS BUILDING REGULATIONS, LOCAL BY-LAWS AND TOWN PLANNING REQUIREMENTS N6 THE BUILDING SHALL BE PROTECTED IN ACCORDANCE WITH AS3660. N7 ALL DIMENSIONS MUST BE VERIFIED BEFORE THE COMMENCEMENT OF ANY SITE WORKS OR DRAWINGS.. ENGINEERS DRAWINGS MUST NOT BE SCALED. ALL DIMENSIONS NOTED ARE IN MILLIMETERES UNLESS NOTED OTHERWISE N8 ALL ELECTRICAL WORK TO COMPLY WITH AS 3008.1.1 – 2009 – ELECTRICAL INSTALLATIONS – SELECTION OF CABLES AND AS 3012 – 2012 – ELECTRICAL N9 ALL MECHANICAL VENTILATION REQUIREMENTS TO COMPLY WITH AS 1668.2 – 2012 – MECHANICAL VENTILATION N10 ALL WINDOWS REQUIREMENTS AND INSTALLATION TO COMPLY WITH AS 2047 – 1999 – WINDOWS IN BUILDINGS – SELECTION AND INSTALLATION N11 ALL GLAZING, INTERNAL AND EXTERNAL TO COMPLY WITH AS 1288 – 2006 – GLASS IN BUILDINGS – SELECTION AND INSTALLATION AND HB 125 – THE GLASS AND GLAZING HANDBOOK N12 ALL GLAZING IN THE BATHROOM, ENSUITE AND SHOWERS INCLUDING SHOWER DOORS, BATH ENCLOSURES, UNSUPPORTED MIRRORS AND WINDOWS) SHALL BE 'GRADE A' SAFTY GLAZING MATERIAL. N13 THE RETAINING STRUCTURE IS TO COMPLY WITH AS 4678 – 2002 – EARTH RETAINING STRUCTURES N14 SOIL CLASSIFICATION: ADOPT CLASS M, REFER TO ENGINEERS REPORT AND CONFIRM ON-SITE. ADOPT BAL RATING 29 N15 GUTTERS AND DOWNPIPES TO BE IN ACCORDANCE WITH AS 3500.3 STORM WATER DRAINAGE AND B.C.A CL3.5.2 AND CL3.1.2 N16 ALL CONCRETE SLABS TO COMPLY WITH B.C.A AND AS 2870 RESIDENTIAL SLABS AND FOOTINGS N17 EXCAVATION OF TRENCHES FOR SEWERAGE, DRAINAGE ETC. TO BE CARRIED OUT IN ACCORDANCE WITH CONTROLLING ATHORITIES REQUIREMENTS. N18 TOP SOIL AND VEGETATION UNDER SLAB TO BE REMOVED. N19 ROOF SHEETING AND ROOF PENETRATIONS TO COMPLY WITH B.C.A. CL N20 ROOF AND WALLS MUST BE INSULATED AS PER B.C.A. 3.12.1.1 N21 ALL ELECTRICAL INSTALLATION TO CONFIRM TO AS 3000 N22 ALL MASONRY TO CONFORM WITH B.C.A CL 3.3.1 AND AS 3700 MASONRY. N23 ALL TIMBER FRAME TO CONFORM TO AS 1684.4 AND THE TIMBER FRAMING MANUAL. N24 METAL LINTELS IN EXTERNAL WALLS TO BE HOT DIPPED GALVANISED. N25 WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZE WILL VARY ACCORDING TO MANUFACTURERE, N26 GLAZING TO CONFORM WITH AS1288 AND AS2047. GLAZING FLASHINGS TO COMPLY WITH B.C.A. CL 3.5.3.6 AND AS 2904. N27 STORM WATER DRAINS TO BE TAKEN TO THE LEGAL POINT OF DISCHARGE AS DIRECTED BY THE LOCAL COUNCIL AND AND PLANS. N28 EXCAVATION OF TRENCHES FOR SEWERAGE, DRAINAGE ETC, TO BE CARRIED OUT IN ACCORDANCE WITH CONTROLLING AUTHORITIES REQUIREMENTS. SHEET LIST FOREWORD SOLE PROPRIETOR: MR AND MRS M METCALF OF 24 FINCH STREET BEECHWORTH VIC 3747. LOCAL GOVERNING COUNCIL: INDIGOE SHIRE COUNCIL ARCHITECT: HALEN T MOKA FOR ANY FURTHER INFORMATION CONTACT HALEN T MOKA HERE: PH: 0410 522 743 OR HALENMOKA@GMAIL.COM THIS DOCUMENT HAS BEEN PROVIDED BY HALEN MOKA OF FORTITUDE - DESIGN AND BUILD, ON BEHALF OF MR AND MRS M METCALF, IN CONJUNCTION WITH ENGINEERS SPECIFICATIONS AND DRAWINGS AT THE REQUEST OF THE BUILDING PERMIT APPLICATION PROCEDURES OF THE INDIGOE SHIRE COUNCIL. THIS DOCUMENT MUST BE ASSESSED AND CONSIDERED AS A COMPONENT IN A SERIES OF REQUESTED DOCUMENTS FOR THE APPLICATION OF A BUILDING PERMIT FOR THE RESIDENTIAL DEVELOPMENT AT 24 FINCH STREET BEECHWORTH, VIC, 3747. FORTITUDE TAKES NO RESPONSIBILITY FOR ANY DAMAGES TO ANY INDIVIDUALS HEALTH OF FINANCIAL DAMAGES THAT MAY OCCUR TO ANY THIRD PARTY ASSOCIATIONS WHEN USING THESE CONSTRUCTION DRAWINGS AS A GUIDE IN ANY PROJECT. MR AND MRS M METCALF 24 FINCH STREET BEECHWORTH 3747 DEMOLITION OF EXISTING DWELLING AND CONSTRUCTION OF PROPOSED SINGLE STORY DWELLING WITH ATTATCHED GARAGE. CLIENT: ADDRESS: PROJECT: Scale Checked by Drawn by Date Project number 1 : 100 Schedules P1.0 FINCH STREET NEW DWELLING MR A AND MRS M METCALF Issue Date Author HALEN MOKA 24 FINCH STREET, BEECHWORTH VIC W01 Door Schedule Level Mark Location Height Width Thickness Finish Frame Material Comments Ground Floor 1 MASTER 2134 915 51 NATURAL WHITE CEDAR SWINGING Ground Floor 2 BATHROOM 2134 813 51 NATURAL WHITE CEDAR SWINGING Ground Floor 3 LAUNDRY 2134 915 51 NATURAL WHITE CEDAR SWINGING Ground Floor 4 BED 1 2134 915 51 NATURAL WHITE CEDAR SWINGING Ground Floor 5 BED 2 2134 915 51 NATURAL WHITE CEDAR SWINGING Ground Floor 6 BED 2 2032 1230 51 NATURAL WHITE CEDAR DOUBLE SWINGING Ground Floor 7 BED 1 2032 1230 51 NATURAL WHITE CEDAR DOUBLE SWINGING Ground Floor 8 GARAGE 2134 813 51 NATURAL WHITE TURPENTINE SWINGING W/NON-COMBUSTIBLE WEATHER STRIP Ground Floor 9 STORAGE 2032 762 51 NATURAL WHITE CEDAR SWINGING Ground Floor 10 STUDY 2134 915 51 NATURAL WHITE CEDAR SWINGING Ground Floor 11 LAUNDRY 2134 915 51 NATURAL WHITE CEDAR SWINGING Ground Floor 12 MASTER 2438 3658 250 DOUBLE BASS TURPENTINE DOUBLE SLIDING Ground Floor 13 BED 1 2432 1730 120 DOUBLE BASS TURPENTINE SINGLE SLIDING Ground Floor 14 FRONT DOOR 2040 820 51 DOUBLE BASS TURPENTINE SWINGING W/NON-COMBUSTIBLE WEATHER STRIP Ground Floor 15 BED 2 2432 1730 120 DOUBLE BASS TURPENTINE SINGLE SLIDING W/NON-COMBUSTIBLE WEATHER STRIP Ground Floor 16 LAUNDRY 2432 1730 120 DOUBLE BASS TURPENTINE SINGLE SLIDING W/NON-COMBUSTIBLE WEATHER STRIP Ground Floor 17 LIVING 2438 3658 250 DOUBLE BASS TURPENTINE DOUBLE SLIDING NON-COMBUSTIBLE WEATHER STRIP Ground Floor 18 HALL 2438 6658 300 DOUBLE BASS TURPENTINE 4 PANEL SLIDING NON-COMBUSTIBLE WEATHER STRIP Ground Floor 19 DINING 2550 3900 80 DOUBLE BASS TURPENTINE DOUBLE SLIDING NON-COMBUSTIBLE WEATHER STRIP Ground Floor 20 HALL 2982 1430 50 DOUBLE BASS TURPENTINE GLASS SWINGING 9MM TOUGHENED GLASS W/NON-COMBUSTIBLE WEATHER STRIP Ground Floor: 20 Grand total: 20 Window Schedule Mark Location Window Style Width Height Material Glazing Remarks 1 PANTRY FIXED 406 1830 TURPENTINE SINGLE 9MM TOUGHENED FROSTED GLASS ARGON FILLED AND THERMALLY BROKEN 2 BATHROOM AWNING 915 1220 ALUMINIUM 9MM TOUGHEND GLASS DBL GLAZED ARGON FILLED AND THERMALLY BROKEN 3 ENSUITE AWNING 3339 458 ALUMINIUM 9MM TOUGHEND GLASS DBL GLAZED ARGON FILLED AND THERMALLY BROKEN 4 KITCHEN AWNING 610 1220 ALUMINIUM 9MM TOUGHEND GLASS DBL GLAZED ARGON FILLED AND THERMALLY BROKEN 5 STUDY AWNING 610 1830 ALUMINIUM 9MM TOUGHEND GLASS DBL GLAZED ARGON FILLED AND THERMALLY BROKEN 6 STUDY AWNING 610 1830 ALUMINIUM 9MM TOUGHEND GLASS DBL GLAZED ARGON FILLED AND THERMALLY BROKEN 7 BED 2 AWNING 1400 1200 ALUMINIUM 9MM TOUGHEND GLASS DBL GLAZED ARGON FILLED AND THERMALLY BROKEN 8 KITCHEN AWNING 610 1220 ALUMINIUM 9MM TOUGHEND GLASS DBL GLAZED ARGON FILLED AND THERMALLY BROKEN 9 KITCHEN AWNING 610 1220 ALUMINIUM 9MM TOUGHEND GLASS DBL GLAZED ARGON FILLED AND THERMALLY BROKEN Sheet List Sheet Number Sheet Name W01 Schedules W02 Site Plan W03 Landscaping Plan W04 Site Drainage Plan W05 Roof Plan W06 East/West Elevations W07 North/ South Elevations W08 Sections W09 Sections II W10 Electrical Plan W11 Reflected Ceiling Plan W12 Floor Plan W13 Slab Plan W14 Internal Elevations W15 Internal Elevations II W16 Details W17 Details II PRODUCED BY AN AUTODESK STUDENT PRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT
  • 2.
    1000 1940 1195 13170 50180 14800 3500 N O RTH 5170 0 0 51750 0 518 0 0 0 5190 0 0 PROPOSED CONCRETE DRIVEWAY MACHINEDFINISH IN-GROUND POOL EXISTING UNSEALED DRIVEWAY CONCRETE FOOTPATH EXISTING CONCRETE CROSSOVER PROPOSED CONCRETE CROSSOVER CONCRETEFOOTPATH CONCRETEFOOTPATH DECKING PP 48°00'00'' 48°00'00'' 42°00'00'' 42°00'00'' EXISTING SINGLE STORY DWELLING TO BE COMPLETELY DEMOLISHED EXISTINGFENCINGTO BEREMOVED WM 2426 GATE TWO STOREY DWELLING LIGHT WEIGHT CONSTRUCTION W/ HIGH PITCHED GABLE ROOF. ATTATCHED MULTIPLE GABLE ROOF SINGLE STOREY EXTENSIONS SW SWSWSWSW SWSW SW SW SW SW SW SW SW SW 1000 SW SW SW SW SW SW SWSW S S S S S S S S S S S S W W W W W W W WW S STORMWATER PIPES TO CONNECT TO LPD PROPOSED SINGLE STORY DWELLING DECKING POOL GATE TO OPEN AWAY FROM POOL WITH SELF CLOSING SAFETY LATCH 1500MM HIGH MIN. HABITABLE WINDOWS 1246 GATE GRASS LAWN ECO OUTDOOR DRYSTONE PAVERS INSTALLED TO MAUNFS SPECS DP DP DP DPDPDP DP DP DP Site Notes DEMOLITION NOTES: EXISTING SINGLE DWELLING AND EXISTING FENCING ON SITE TO BE DEMOLISHED IN ACCORDANCE WITH AS 2601 THE DEMOLITION OF STRUCTURES AND VICTORIAS CODE OF PRACTICE FOR DEMOLITION. TECHNIQUES FOR THE PREVENTION OF DUST, WATER- RUN OFF AND ANY MATERIALS FROM DAMAGING THE AMENITY OF THE SURROUNDING AREA MUST BE IMPLEMENTED. THE LARGE ELM TREE TO BE RETAINED MUST BE PROTECTED DURING DEMOLITION AND CONSTRUCTION. SEWERAGE NOTIES: SEWERAGE PIPES ARE U-PVC DN150 WITH A 1:100 FALL IN ACCORDANCE WITH AS 3500.2 SANITARY PLUMBING AND DRAINAGE SYSTEMS. A DN150 INSPECTION SHAFT MUST BE INSTALLED AS CLOSE TO THE SEWER CONNECTION AS POSSIBLE. CLEAR OF ALL EASEMENTS AND IN THE OPEN AS TO BE ACCESSIBLE. tHEY MUST TERMINATE AT OR NEAR GROUND LEVEL WITH A REMOVABLE AIRTIGHT DN150 INSPECTION CAP. STORM WATER NOTES: PIPES TO BE MADE OF U-PVC DN150 PIPE AT 1:100 FALL.. MUST BE A 300MM SEPERATION BETWEEN ANY UNDERGROUND WATER SERVICE PIPE, GAS PIPE AND/OR ELECTRICAL SUPPLY CABLES. ELECTRICTY CABLES NOTES: MUST BE INDICATED ALONG ITS LENGTH WITH ORANGE MARKER TAPE 150MM ABOVE THE INSTALLED PIPE. MUST BE BACKFILLED APPROPRIATELY COMPLYING WITH AS/NZS 2681.1, AS/NZS 3500.5 AND AS/NZS 3500.3. THE PROPOSED CONSTRUCTION DOES NOT REQUIRE THE NEED FOR EARTH FILL AS THE CONCRETE SLAB STEPS UP THE SLOPE OF THE LAND. A CUT WILL BE MADE NEAR THE SOUTHERN END OF THE PROPERTY AND 900MM TIMBER RETAINING WALL WILL BE CONSTRUCTED AS SHOWN ON THE PLAN AND W15 RETAINING WALL DETAIL. LEGEND SEWERAGE STORM WATER DOWNPIPE POWER LINES PROPOSED UNDERGROUND POWER CABLE POWERPOLE PROPOSED UNDERGROUND WATER PIPE WATER MAIN PROPOSED GATE PROPOSED 2M PRIVACY FENCE W/400MM PRIVACY LATTICE EXISTING 2M METER FENCE SITE CUT AREA 900MM RETAINING WALL PP WM General Notes SITE AREA: 650M BUILDING AREA: 307M BUILDING AREA PERCENTAGE: 47% WIND ZONE: N1 SOIL CLASSIFICATION: M BAL RATING: BAL 12.5 EXISTING BUILDING TO BE DEMOLISHED TREES TO BE REMOVED TREE TO BE KEPT CONTOUR LINES W P P SW S DP Scale Checked by Drawn by Date Project number 1 : 100 Site Plan P1.0 FINCH STREET NEW DWELLING MR A AND MRS M METCALF Issue Date Author HALEN MOKA 24 FINCH STREET, BEECHWORTH VIC W02 PRODUCED BY AN AUTODESK STUDENT PRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT
  • 3.
    N O RTH 5170 0 0 51750 0 518 0 0 0 5190 0 0 PROPOSED CONCRETE DRIVEWAY MACHINEDFINISH IN-GROUND POOL PORCH EXISTINGFENCINGTO BEREMOVED RETAININGWALL Scale Checked by Drawn by Date Project number 1 : 100 Landscaping Plan P1.0 FINCH STREET NEW DWELLING MR A AND MRS M METCALF Issue Date Author Checker 24 FINCH STREET, BEECHWORTH VIC W03 SITE AREA: 650M BUILDING AREA: 307M BUILDING AREA PERCENTAGE: 47% WIND ZONE: N1 SOIL CLASSIFICATION: M TREE TO BE PLANTED SMALL GRASS PLANT TREES TO BE REMOVED ELM TREE TO BE KEPT AND PROTECTED site notes LARGE ELM TREE IN THE CENTRE OF THE PROPERTY TO BE KEPT AND PROTECTED DURING CONSTRUCTION IN ACCORDANCE WITH AS 4970 PROTECTION OF TREES ON DEVELOPMENTS. TREE PROTECTION ZONE TO BE 4200MM. LARGE ELM TREES ALONG THE NATURE STRIP ARE TO BE PROTECTED AND FENCED TO ENSURE NO DAMAGE OCCURS. ALL GARDEN BEDS TO BE COVERED EVENLY IN TOPSOIL AND DARK RED CORSE BARK. TREES TO BE REMOVED HAVE BEEN DEEMED UNSAFE TO OCCUPANTS AND NEIGHBORS BY A CERTIFIED ARBORIST AND THUS MUST BE REMOVED APPROPRIATELY. TREES MUST BE REMOVED BEFORE DEMOLITION WORKS BEGIN. PAVERS ARE TO BE TRAVERTINE CAPRI PAVERS FROM ECO-OUTDOOR. PAVERS ARE TO BE SEMI-SUBMERGED BELOW THE EARTH ON A 50MM BED OF SAND AS TO PREVENT MOVEMENT AND ENSURE A SECURE POSITION. general notes legend DILLWYNIA CINERASCENS GREY PARROT-PEA GREVILLEA APLINA CATS CLAW GREVILLEA ACACIA ACINACEA GOLD DUST WATTLE JOYCEA PALLIIDA SILVERTOP WALLABY-GRASS XANTHORRHOEA PREISSII WESTERN AUSTRALIAN GRASSTREE vegetation name type no. TREE TO BE PLANTED SHRUB 20CM TO 1M 40 MEDIUM SHRUB 1M TO 5M 20 LARGE GRASS LIKE PLANT 6 >1M MEDIUM GRASS TREE .UP TO 5M 2 PRODUCED BY AN AUTODESK STUDENT PRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT
  • 4.
    N O RTH 5170 0 0 51750 0 518 0 0 0 5190 0 0 PROPOSED CONCRETE DRIVEWAY MACHINEDFINISH IN-GROUND POOL PORCH EXISTINGFENCINGTO BEREMOVED SITE NOTES IMPERMEABLE AREA: 267M SITE AREA: 650M PERMEABLE AREA PERCENTAGE: 38% SOIL CLASSIFICATION: M general NOTES ALL SOIL MUST SLOPE AWAY FROM BUILDING FOR A MINIMUM OF 1M. AGGREGATION PIPE TO BE VINIDEX 100MM X 20M SLOTTED DRAINCOIL AND INSTALLED BELOW AND BEHIND THE RETAINING WALL ABOVE GEO FABRIC AND COVERED IN CORSE GRANULAR FILL. GEO FABRIC MUST BE USED TO SEPERATE THE GRANULAR FILL AND SOIL BEHIND THE RETAINING WALL. A 0.2 POLYETHYLENE VAPOUR BARRIER MUST BE USED TO DIRECT WATER BUILDUP TO THE AGGREGATION PIPE AND PREVENT WATER FROM TRANSFERRING THROUGH THE WALL SEE RETAINING WALL DETAIL ON W15. ANY PLUMBING WORKS CARRIED OUT THAT DOES NOT COMPLY WITH THE RELEVANT PLUMBING REGULATIONS AND CONTRACT DOCUMENTS WILL BE CONSIDERED DEFECTIVE. CONSTRUCTION TOLERANCES INCLUDE 19MM FOR LEVEL GUTTERS AND 13MM FOR SLOPING GUTTERS. THIS MUST BE ADHEARED TO. GUTTERS SHALL NOT RETAIN MORE THAN 10MM OF WATER. LEAKS ARE CONSIDERED A DEFECT. PVC PIPES SHALL HAVE A MEAN OUTSIDE DIAMETER OF 110 AND 100.4MM, A MEAN INTERNAL DIAMETER OF 98MM AND A MAXIMM OUT OF SQUARENESS OF 4MM. RETAININGWALL SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SWSW SW SWSW DP DP DP DP DP DP DP DP DP ROOF PITCH 7 DEGREES ROOF PITCH 35 DEGREES ROOF PITCH 35 DEGREES ROOF PITCH 7 DEGREES RAIN GARDEN COLLECTS WATER RUNOFF FROM DRIVEWAY WATER RUNOFF TO DRAIN NATURALLY THROUGH GRASS LAWN AND SURROUNDING RAIN GARDENS RAIN GARDEN COLLECTS EXCESS WATER RUNOFF FROM GRASS LAWN RAIN GARDEN COLLECTS EXCESS WATER RUNOFF AND DRAINS IN VINIDEX 100MM X 20M SLOTTED DRAINCOIL TO STORM WATER PIPES LAND SLOPES AWAY FROM HOUSE FOR 1 A MINIMUM OF 1M. WATER RUNOFF DRAINS TO VINIDEX 100MM X 20M SLOTTED DRAINCOIL UNDERNEATH RETAINING WALL STORM WATER SYSTEM SPECIFICATIONS: DOWNPIPES TO BE DN 100 TYPE C U-PVC DOWNPIPE LOW GLOSS FINISH W/ 200mm X 200mm METAL RAINWATER HEAD FIXED TO CLADDING USING MANUFACTURERS SPEC. GUTTERS TO BE 90MM COLOURBOND LYSAGHT QUAD GUTTER PAINTED 'MONUMENT' COLOUR. FIXED TO MANUFACTURERES SPECS. STORM WATER PIPES TO BE MADE OF U-PVC DN150 PIPE AT 1:100 FALL.. MUST BE A 300MM SEPERATION BETWEEN ANY UNDERGROUND WATER SERVICE PIPE, GAS PIPE AND/OR ELECTRICAL SUPPLY CABLES. STORM WATER PIPES TO FLOW DOWN HILL AND CONNECT TO LEGAL POINT OF DISCHARGE AT THE FRONT OF THE PROPERTY. LEGEND STORM WATER PIPE AGGREGATION PIPE FALL DIRECTION INDICATOR CONTOUR LINES UNDERGROUND PIPES LOCATED EXTERNALLY FROM THE BUILDING SHALL BE IN A 2M DEEP TRENCH BY 0.3M WIDE. THE PIPES SHALL BE LAID ON A BED OF MINIMUM 75MM OF CRUSHED ROCK OR GRAVEL UP TO A MAXIMUM SIZE OF 14MM. THERE MUST BE A MINIMUM OF 100MM BETWEEN THE PIPE AND THE SIDES OF THE TRENCH. SCREENED CRUSHED ROCK SIZES 3MM TO 20MM TO BE USED AS THE GRANULAR FILL FILTER MATERIAL FOR AGGREGATION PIPES. PIPES MUST DISCHARGE TO TO THE LEGAL POINT OF DISCHARGE. THE LOCATION OF THE LEGAL POINT OF DISCHARGE WILL BE DETERMINED BY THE AUTHORITY HAVING JURISDICTION. THE CONNECTION WILL BE LOCATED OUTSIDE THE PROPERTY AND CONNECT TO AN ELEMENT OF THE EXTERNAL STORM WATER DRAINAGE NETWORK AND MAINS PIPES. Scale Checked by Drawn by Date Project number 1 : 100 Site Drainage Plan P1.0 FINCH STREET NEW DWELLING MR A AND MRS M METCALF Issue Date Author HALEN MOKA 24 FINCH STREET, BEECHWORTH VIC W04 PRODUCED BY AN AUTODESK STUDENT PRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT
  • 5.
    DECKING DN 100 TYPEC U-PVC DOWNPIPE LOW GLOSS FINISH 200mm X 200mm METAL RAINWATER HEAD RWH 200X200 METAL RAIN WATER HEAD COLORBOND LOW GLOSS FINISH MONUMENT COLOUR RWH DP DPDP DP INDICTIVE POSITION OF 2500L RHEEM PREMIER® HILINE SOLAR HOT WATER HEATER GAS BOOSTED. MODEL: 52H180K/1S-G INSTALLED TO MANUFACTURERES SPECIFICATIONS INDICTIVE POSITION OF PREMIUM LINE GERMAN SOLAR, SOLAR PANELS INSTALLED TO MANUFACTURERES SPECIFICATIONS 90MM METAL COLOURBOND LYSAGHT QUAD GUTTER 'MONUMENT' FIXED TO MANUFACTURERES SPECS 3 DEGREE FALL ROOF PITCH 35 DEGREES ROOF PITCH 35 DEGREES EXHAUST FAN INSTALLED TO MANUFACTUERES SPECIFICATIONS SEALED WITH A NON-COMBUSTIBLE SEALANT. 620X150 VELUX OPENABLE ROOF WINDOWS INSTALLED TO MANUFACTURERES SPECIFICATIONS 620X150 VELUX OPENABLE ROOF WINDOWS POOL RANGEHOOD EXHAUST FAN INSTALLED TO MANUFACTUREERS SPECIFICATIONS 150X150 STEEL COLOURBOND RIDGE CAPPING 'MONUMENT' COLOUR. 0.42 BMT WITH A RECESSED CUT TO MATCH COLOURBOND TRIMDEK PROFILE. FLOW DIRECTION INDICATOR DP 6MM ALUCOBOND SHEETING WITH A 5MM DEEP BY 10MM WIDE ROUTE LINE AT 900 CENTRES. LOW GLOSS SOLID ANTHRAZIT GREY- 105 COLOUR SEALED WITH BLACK WATERPROOF EXTERIOR SEALANT. ALUCOBOND MUST BE 70% NON- COMBUSTIBLE OR MORE AND COMPLY WITH AS 1530.3. GROUP 1 RATING WHEN TESTED TO ISO 9705. ROOF PITCH 7 DEGREES ROOF PITCH 7 DEGREES ULTRA RANGE TRIMDEK COLORBOND SHEETING MONUMENT COLOUR 3 DEGREE FALL 6MM ALUCOBOND SHEETING WITH A 5MM DEEP BY 10MM WIDE ROUTE LINE AT 900 CENTRES. LOW GLOSS SOLID ANTHRAZIT GREY- 105 COLOUR ALUCOBOND MUST BE 70% NON- COMBUSTIBLE OR MORE AND COMPLY WITH AS 1530.3. GROUP 1 RATING WHEN TESTED TO ISO 9705. 620X150 VELUX OPENABLE ROOF WINDOWS INSTALLED TO MANUFACTURERES SPECIFICATIONS GLAZING AND SEALANTS AND FLASHINGS TO COMPLY WITH AS 3959. FASCIA COLOURBOND STRAMIT METAL MONMUMENT COLOUR FASCIA COLOURBOND STRAMIT METAL MONMUMENT COLOUR FASCIA COLOURBOND STRAMIT METAL MONMUMENT COLOUR HOT WATER SYSTEM NOTES: HWS TO BE RHEEM PREMIER® HILINE SOLAR HOT WATER HEATER GAS BOOSTED. MODEL: 52H180K/1S-G SOLAR COLLECTORS: S200 X2 BOOSTER TYPE GAS: REMOTE GAS 27L/MIN HOT WATER HEATER MUST BE INSTALLED IN ACCORDANCE WITH AS3500.4 HEATED WATER SERVICE AND AS3500.5 DOMESTIC INSTALLATIONS. SOLAR PANELS TO BE FIXED ON TOP OF ROOF AND COLLECTORS SHOULD BE INCLINED AT A SIMILAR ANGLE TO THE LATITUDE ANGLE AND SHOULD BE LOCATED AS TO BE CLEAR OF SHADE FOR 3 HOURS EITHER SIDE OF SOLAR NOON. THE DEVIATION FROM THIS ANGLE SHOULD BE NOT GREATER THAN ±20° AS PER MANUFACTURERS SPECIFICATIONS AND AS 3500.4 HEATED WATER SERVICES. THE HOT WATER SYSTEM IS TO BE INSTALLED ABOVE THE STUDY ON THE ROOF. IT MUST BE EASILY ACCESSIBLE TO RELIEF VALVES AND BE EASILY REMOVABLE WITHOUT MAJOR STRUCTURAL ALTERATIONS TO THE BUILDING OR PIPEWORK. HOT WATER SYSTEM MUST BE CONNECTED TO THE 10 HOT WATER OUTLETS THROUGHOUT THE BUILDING. CONSIDERATION SHALL BE GIVEN TO THE ROUTE TAKEN BY VENT PIPES, DRAIN LINES OR SAFE WASTES. General Notes GUTTER FLOW DIRECTION GUTTER FLOW DIRECTION CHANGE DOWNPIPE EXHAUST FAN RAINWATER HEAD SKYLIGHT LEGEND DP RWH DP FLASHINGS TO BE INSTALLED TO MANUFACTURERES SPECIFICATIONS. DOWNPIPES MUST NOT HAVE MORE THAN 50 SQUARE METERS OF ROOFING SURFACE ALLOCATED TO ANY SINGLE DOWNPIPE. DOWNPIPES ARE 100 MM DIA METAL PIPE. REF: BCA 3.5.2.5 FOR INSTALLATION. DRAINAGE OF STORMWATER MUST BE DRAINED CORRECTLY AND IN ACCORDANCE WITH AS3500.4 3 SOLAR PANELS TO BE INSTALLED ON THE EASTERN MOST POINT OF THE ROOF. REFER TO MAUFACTURERES SPECIFICATIONS FOR INSTALLATION. ANY VENTS AND ALL MECHANICAL VENILATION TO BE SEALED AND MUST COMPLY WITH AS1668.2 ROOF TO BE SARKED AND OVER LAPPED 200MM WHERE NEW SHEETS JOIN HORIZONTALLY. SARKING MUST DRAIN INTO GUTTER. RAINWATER HEAD INSTALLED TO MANUFACTURERES SPECS. COLOURBOND ROOFING SPECIFICATIONS: MATERIAL: COLORBOND® STEEL CONFORMING TO AS 1397-G550-AM100 AND AS 2728. COLOUR: MONUMENT® THICKNESS: 0.42 BMT FIXING METHOD: FASTENERS SHOULD BE SELECTED TO MATCH THE GRADE OF THE ROOFING MATERIAL. SIZE: AS PER ROOF SIZE. SPACING: 1200MM PROFILE: TRIMDEK ROOF CONTRACTOR: THE ROOF SHEETING, WALLING AND ACCESSORIES SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. VELUX ROOF WINDOWS SPECIFICATIONS: VELUX ROOF WINDOWS AND MATERIALS THAT IT CONSISTS OF TO MEET THE REQUIREMENTS OF AS4285 SKYLIGHTS, AS1288 OVERHEAD GLAZING AND AS3959 BUSHFIRE FOR BAL 40 REQUIREMENTS AND AS1530.1 NON-COMBUSTIBILITY.. MUST BE INSTALLED TO MANUFACTURERES SPECIFICATIONS AND SEALED APPROPRIATELY TO ENSURE THERE IS NO WATER INGRESS. ALUCOBOND® PLUS SPECIFICATIONS: ALUCOBOND® PLUS ALUMINIUM COMPOSITE MATERIAL (ACM) SHALL BE 6MM THICK AND CONSIST OF 2 LAYERS OF 0.5MM THICK ALUMINIUM SANDWICHING A MINERAL FILLED FIRE RESISTANT CORE CONTAINING 70% NON COMBUSTIBLE MINERAL FILLING. THE ALUMINIUM SKINS SHALL BE OF ALLOY ALMG 1- NS41 (EN AW 5005A NEAREST EQUIVALENT) HAVING AN ULTIMATE STRENGTH OF 130 MPA AND 0.2% PROOF STRESS OF 90 MPA. ALUCOBOND SHEETING MUST BE FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS EVERY 100MM AROUND THE EDGES TO TIMBER BATTENS AND STUDS. BE SURE TO FIX EXTRA TIMBER PEICES AROUND ALUCOBOND EDGES WHERE THERE ARE GAPS AND NO TIMBER TO FIX TO. MUST COMPLY WITH THE REQUIREMENTS OF BAL 12.5 IN AS 3959 . PITCH CHANGE FLASHING STEEL FLASHING MUST BE USED WHERE ROOF PITCHES CHANGE AND MUST EXTEND UNDERNEATH THE UPPER ROOF WITH A 20MM RETURN FOLD, AND THEN OVER THE TOP OF THE LOWER ROOF WITH A BREAK TO SUIT THE ROOFING PROFILE (CORRUGATED IRON). TO MINIMISE THE PROBLEM OF WIND DRIVING WATER UP-HILL THE TOP ENDS OF THE LOWER ROOF SHOULD BE TURNED UP. THE END OF THE FLASHING THAT SITS ABOVE THE LOWER ROOF AND OVERLAPS BY 150MM, MUST HAVE A NOTCHED BREAK TO ALLOW THE ROOF PROFILE TO BE FITTED INTO THE FLASHING TO GIVE GREATER PROTECTION FROM WATER BLOWING BACK UNDER THE FLASHING. SEE W16 ROOF PITCH CHANGE LONGITUDINAL FLASHINGS SHALL 0.42BMT STEEL AND BE FASTENED AT MAXIMUM 500MM CENTRES. LONGITUDINAL FLASHINGS SHALL 0.42BMT STEEL AND BE FASTENED AT MAXIMUM 500MM CENTRES LONGITUDINAL 0.42BMT STEEL FLASHINGS MUST BE FASTENED AT MAXIMUM 500MM CENTRES. 6MM ALUCOBOND SHEETING WITH A 5MM DEEP BY 10MM WIDE ROUTE LINE AT 900 CENTRES. LOW GLOSS SOLID ANTHRAZIT GREY- 105 COLOUR ALUCOBOND MUST BE 70% NON-COMBUSTIBLE OR MORE AND COMPLY WITH AS 1530.3. GROUP 1 RATING WHEN TESTED TO ISO 9705. 90MM METAL COLOURBOND LYSAGHT QUAD GUTTER 'MONUMENT' FIXED TO MANUFACTURERES SPECS 3 DEGREE FALL 90MM METAL COLOURBOND LYSAGHT QUAD GUTTER 'MONUMENT' FIXED TO MANUFACTURERES SPECS 3 DEGREE FALL Scale Checked by Drawn by Date Project number 1 : 100 Roof Plan P1.0 FINCH STREET NEW DWELLING MR A AND MRS M METCALF Issue Date Author HALEN MOKA 24 FINCH STREET, BEECHWORTH VIC W05 PRODUCED BY AN AUTODESK STUDENT PRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT
  • 6.
    350 738 1691 1 W09 3421 121315 16 2 3 456 7 8 9 ECO OUT DOOR DRYSTONE WALL"ALPINE" INSTALLED TO MANUFACTURERES SPECS 100X25 TURPENTINE DECKING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL SELF DRILLING SCREWS 100X25 TURPENTINE CLADDING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL CLOUTS ALUCOBOND SPARKLING BLACK METALLIC 888 SEALED WITH BLACK SILICONE FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS ALUCOBOND SPARKLING BLACK METALLIC 888 SEALED WITH BLACK SILICONE FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS DN 100 TYPE C METAL DOWNPIPE 'MONUMENT' LOW GLOSS FINISH 220mm X 140mm METAL RAINWATER HEAD FIXED TO CLADDING USING MANUFACTURERS SPECS DN 100 TYPE C METAL DOWNPIPE 'MONUMENT' LOW GLOSS FINISH 220mm X 140mm METAL RAINWATER HEAD FIXED TO CLADDING USING MANUFACTURERS SPECS INDICTIVE POSITION OF PREMIUM LINE GERMAN SOLAR, SOLAR PANELS INSTALLED TO MANUFACTURERES SPECIFICATIONS 100X25 TURPENTINE DECKING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL SELF DRILLING SCREWS . COLOURBOND CORRGATED ROOFING IRON INSTALLED TO MANUFCTURERES SPECS 'MONUMENT' ECO OUT DOOR DRYSTONE PAVERS "ALPINE" INSTALLED TO MANUFACTURERES SPECS COLOURBON IRON RIDGE CAPPING FIXED TO MANUYFACTURERES SPECIFICATIONS 'MONUMENT' RETAINING WALL SEE DETAIL HIGHGROVE 9MM TOUGHENED SAFETY GLASS 1200X1300X12 PANEL STAINLESS STEEL FIXING TO MANUFACTURERES SPECIFICATIONS INDICTIVE POSITION OF PHOTOVOLTAICS FOR SOLAR HOT WATER SYSTEM INSTALLED TO MANUFACTURERES SPECIFICATIONS 90MM METAL COLOURBOND LYSAGHT QUAD GUTTER 'MONUMENT' FIXED TO MANUFACTURERES SPECS INDICTIVE POSITION OF 2500L RHEEM PREMIER® HILINE SOLAR HOT WATER HEATER GAS BOOSTED. MODEL: 52H180K/1S-G INSTALLED TO MANUFACTURERES SPECIFICATIONS SKYDOME LOW E DOUBLE GLAZED BLACK ALUMINIUM FRAME INSTALLED TO MANUFACTURERES SPECS 180 STEP DOWN ON DECKING. 5960 NATURAL GROUND LEVEL 1788 1050 600 688 1 W09 ALUCOBOND SPARKLING BLACK METALLIC 888 SEALED WITH BLACK SILICONE FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS SKYDOME LOW E DOUBLE GLAZED BLACK ALUMINIUM FRAME INSTALLED TO MANUFACTURERES SPECS COLOURBOND CORRGATED ROOFING IRON INSTALLED TO MANUFCTURERES SPECS 'MONUMENT' 100X25 TURPENTINE CLADDING INTERGRAIN REDWOOD STAIN FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS ECO OUT DOOR DRYSTONE WALL"ALPINE" INSTALLED TO MANUFACTURERES SPECS DN 100 TYPE C METAL DOWNPIPE 'MONUMENT' LOW GLOSS FINISH 220mm X 140mm METAL RAINWATER HEAD FIXED TO CLADDING USING MANUFACTURERS SPECS DN 100 TYPE C METAL DOWNPIPE 'MONUMENT' LOW GLOSS FINISH 220mm X 140mm METAL RAINWATER HEAD FIXED TO CLADDING USING MANUFACTURERS SPECS DN 100 TYPE C METAL DOWNPIPE 'MONUMENT' LOW GLOSS FINISH 220mm X 140mm METAL RAINWATER HEAD FIXED TO CLADDING USING MANUFACTURERS SPECS ALUCOBOND SPARKLING BLACK METALLIC 888 SEALED WITH BLACK SILICONE FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS ALUCOBOND SPARKLING BLACK METALLIC 888 SEALED WITH BLACK SILICONE FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS 17 18 2090MM COLOURBOND LYSAGHT QUAD GUTTER 'MONUMENT' FIXED TO MANUFACTURERES SPECS 90MM COLOURBOND LYSAGHT QUAD GUTTER 'MONUMENT' FIXED TO MANUFACTURERES SPECS STAINLESSSTEEL POOL LADDER INSTALLED TO MANUFACTURERES SPECIFICATIONS ECO OUT DOOR DRYSTONE WALL"ALPINE" INSTALLED TO MANUFACTURERES SPECS COLOURBON IRON RIDGE CAPPING FIXED TO MANUYFACTURERES SPECIFICATIONS 'MONUMENT' 100X25 TURPENTINE DECKING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL SELF DRILLING SCREWS 100X25 TURPENTINE CLADDING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL CLOUTS COLOURBOND CORRGATED ROOFING IRON INSTALLED TO MANUFCTURERES SPECS 'MONUMENT' SKYLIGHTS TO BE INSTALLED TO MANUFACTURERES SPECIFICIATIONS AND SEALED TO PREVANT WATER INGRES ALL STORMWATER GUTTERS, PIPES AND SERVICES TO BE CONSTRUCTED IN ACCORDANCE WITH ASNZS 3500.3 PASRT 3 STORMWATER DRAINAGE . FEATURE WALL AND STONE WALL AT THE FRONT OF THE PROPERTY AND ATTATCHED CUSTOM MAILBOX TO BE CONSTRUCTED OF ECO-OUTDOOR DRYSTONE 'ALPINE' WALL PANELS GLUED ON TOP OF 6MM FIBRE CEMENT SHEETING APPROPRIATELY FIXED TO A TIMBER WALL FRAMED WALL USING 30MM GAL CLOUTS. THE LOCATION OF THIS WALL AND ASSOCIATED CURVE WILL BE INDICTIVE AND FOLLOW THE EDGE AND LENGTH OF THE DRIVEWAY AND THE FRONT OF THE PROPERTY EDGE UNTILL OT REACHES THE MAILBOX AND FENCE AND THEN CONTINUE UNTILL IT REACHES THE EASTERN FENCE. HEIGHT OF THE FENCE TO STAY LEVEL ALONG ITS LENGTH. RETAINING WALL SEE DETAIL HIGHGROVE 9MM TOUGHENED SAFETY GLASS 1200X1300X12 PANEL STAINLESS STEEL FIXING TO MANUFACTURERES SPECIFICATIONS. SEE BALUSTRADE DETAIL ON W16 INDICTIVE LOCATION OF LANDSCAPING BOULDER IN GARDEN BED 90MM COLOURBOND LYSAGHT QUAD GUTTER 'MONUMENT' FIXED TO MANUFACTURERES SPECS General Notes SERVICES NOTES METERBOX/SWITCHBOARD NOTES: TYPE: RS485 2 WIRE, HALF DUPLEX, ISOLATED BAUD RATE: 600 TO 19200 BPS PROTOCOL: MODBUS RTU FUNCTION: RED/ WRITE SETPOINTS READ ACTUAL VALUES EXECUTE COMMANDS POWER SUPPLY: INPUT: 100V-240V AC 50/60HZ 100V-300VDC POWER: 2W NOTE: BEFORE ANY WORKS BEGIN ON ANY ELECTRICAL CONNECTIONS ON SITE IT IS ADVISED THAT THE RELEVANT AUTHORITY SPI NETWORKS BE CONTACTED. METERBOX/SWTICHBOARD INSTALLATION REQUIREMENTS: THERE MUST BE A SEPARATION OF 300MM BETWEEN ANY UNDERGROUND WATER SERVICE PIPE AND AN ELECTRICAL SUPPLY CABLE. ANY WATER SERVICE PIPE GREATER THAN DN 65 WILL BE INDICATED APPROPRIATELY ALONG ITS LENGTH AT 150MM ABOVE THE PIPE AND MUST ALSO BE MECHANICALLY PROTECTED IN ACCORDANCE WITH ASNZS 3500.5, ASNZS 2648 AND ASNZS 3000. CONDUIT OF DN50 AND CABLES OF DN20 ARE TO BE CONNECTED TO SWITCHBOARD/METER BOX IN ACCORDANCE WITH ASNZS 3000. CIRCTUIT BREAKER REQUIREMENTS: CIRCUIT BREAKERS FOR EACH REQUIRED CIRCUIT ARE TO BE MOUNTED ONTO A CLEARLY IDENTIFIABLE, SINGLE-PHASE SWITCHBOARD AND CORRESPOND TO ACTIVE/NEUTRAL CONNECTIONS. GAS INSTALLATION NOTES: PIPES USED FOR GAS SUPPLY SYSTEM: COPPER DN10 PIPES. iNSTALLATION REQUIREMENTS: THERE MUST BE A SEPARATION OF 300MM BETWEEN ANY UNDERGROUND WATER SERVICE PIPE AND CONSUMER GAS PIPES. ANY WATER SERVICE PIPE GREATER THAN DN 65 WILL BE INDICATED APPROPRIATELY ALONG ITS LENGTH WITH ORANGE MARKER TAPE AT 150MM ABOVE THE PIPE IN ACCORDANCE WITH ASNZS 2648.1 – UNDERGROUND MARKING TAPE AND ASNZS 5601 – GAS INSTALLATIONS. NOTE: BEFORE ANY WORKS BEGIN ON ANY GAS CONNECTIONS ON SITE IT IS ADVISED THAT THE RELEVANT AUTHORITY SPI NETWORKS BE CONTACTED. WALL MUST BE SARKED AND EXTERNALLY FIXED WITH 6MM CEMENT SHEETING USING 30MM GAL CLOUTS. 20X50 VERTICAL TIMBER BATTENS TO BE PLACED AT 600 CNTRS AND FIXED WITH 65MM GAL BATTEN SCREWS. A 12MM GAP AT THE TOP OF THE WALL AND A 200MM GAP AT THE BOTTOM OF THE WALL MUST BE LEFT TO ALLOW AIRFLOW BEHIND THE TIMBER CLADDING. 50X50 HORIZONTAL BATTENS TO BE FIXED TO VERTICAL BATTENS AT 600 CNTRS WITH 65MM BATTEN SCREWS. ENSURE A GAP OF 8MM BETWEEN TIMBER CLADDING AND EDGE BATTEN. EXTRA PEICES OF BATTEN TO BE ATTATCHED AT JOINTS TO FIX SHORTER PEICES OF CLADDING WHERE REQUIRED. 50X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS TO BE USED TO FIX 100X25MM TURPENTINE SHADOW CLADDING. IF NAILS ARE LESS THAN 30MM FROM THE END OF THE PEICE OF TIMBER, A PILOT HOLE MUST BE DRILLED PRIOR TO FIXING. END GRAIN TO BE SEALED AND INTERGRAIN REDWOOD STAIN TO BE APPLIED TO CLADDING AS PER MANUFACTURERES SPECS. ALL DOORS TO BE INSTALLED TO MANUFACTURERES SPECS TIMBER CLADDING MUST NOT SIT ON TIMBER FRAME WATER PROOFING TO OVERHANG OVER DOOR FRAME APPROPRIATELY TO ENSURE CORRECT WATER RUNOFF AND PREVENT MOISTURE BUILD- UP. REFER TO DOOR SCHEDULE FOR DOOR AND GLAZING SPECIFICATIONS. ALL OPENINGS ARE OF NOMINAL HEIGHT AND LENGTH AND MAY VARY. ALL SOIL MUST SLOPE AWAY FROM BUILDING FOR A MINIMUM OF 1M. ARTICULATE MASONRY VENEER WALLS MUST BE CONSTRUCTED IN ACCORDANCE WITH AS 3700 AND AS 1684.4. FIRE RESISTANT TURPENTINE TIMBER TO COMPLY WITH AS3959 TIMBER IN BUSHFIRE PRONE AREAS. APPENDIX E EXTERNAL CLADDING NOTES E G 6443 LETTER BOX 180MM STEP DOWN ON DECKING. Scale Checked by Drawn by Date Project number 1 : 100 East/West Elevations P1.0 FINCH STREET NEW DWELLING MR A AND MRS M METCALF Issue Date Author HALEN MOKA 24 FINCH STREET, BEECHWORTH VIC W06 PRODUCED BY AN AUTODESK STUDENT PRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT
  • 7.
    1 W08 2 W08 ALUCOBOND SPARKLING BLACK METALLIC 888SEALED WITH BLACK SILICONE FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS SKYDOME LOW E DOUBLE GLAZED BLACK ALUMINIUM FRAME INSTALLED TO MANUFACTURERES SPECS COLOURBOND CORRGATED ROOFING IRON INSTALLED TO MANUFCTURERES SPECS 'MONUMENT' 90MM COLOURBOND LYSAGHT QUAD GUTTER 'MONUMENT' FIXED TO MANUFACTURERES SPECS COLOURBON IRON RIDGE CAPPING FIXED TO MANUYFACTURERES SPECIFICATIONS 'MONUMENT' 100X25 TURPENTINE CLADDING INTERGRAIN REDWOOD STAIN FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS ALUCOBOND SPARKLING BLACK METALLIC 888 SEALED WITH BLACK SILICONE FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS 90MM COLOURBOND LYSAGHT QUAD GUTTER 'MONUMENT' FIXED TO MANUFACTURERES SPECS DN 100 TYPE C METAL DOWNPIPE 'MONUMENT' LOW GLOSS FINISH 220mm X 140mm METAL RAINWATER HEAD FIXED TO CLADDING USING MANUFACTURERS SPECS 100X25 TURPENTINE DECKING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL SELF DRILLING DECKING SCREWS COLOURBOND CORRGATED ROOFING IRON INSTALLED TO MANUFCTURERES SPECS 'MONUMENT' HIGHGROVE 9MM TOUGHENED SAFETY GLASS 1200X1300X12 PANEL STAINLESS STEEL FIXING TO MANUFACTURERES SPECIFICATIONS SEE BALUSTRADE DETAIL ON W16 INDICTIVE POSITION OF PREMIUM LINE GERMAN SOLAR, SOLAR PANELS INSTALLED TO MANUFACTURERES SPECIFICATIONS INDICTIVE POSITION OF PHOTOVOLTAICS FOR SOLAR HOT WATER SYSTEM INSTALLED TO MANUFACTURERES SPECs SKYDOME LOW E DOUBLE GLAZED BLACK ALUMINIUM FRAME INSTALLED TO MANUFACTURERES SPECS 100X25 TURPENTINE CLADDING INTERGRAIN REDWOOD STAIN FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS 100X25 TURPENTINE DECKING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL SELF DRILLING SCREWS . ECO OUT DOOR DRYSTONE PAVERS "ALPINE" INSTALLED TO MANUFACTURERES SPECS 0201 03 04 05 06 14 SCHWEISS CUSTOM DESIGNED BI-FOLD MECHANICAL DOORS INSTALLED TO MANUFACTURERES SECS. WITH 100X25 TURPENTINE CLADDING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL CLOUTS 07 WALL MUST BE SARKED AND EXTERNALLY FIXED WITH 6MM CEMENT SHEETING USING 30MM GAL CLOUTS. 20X50 VERTICAL TIMBER BATTENS TO BE PLACED AT 600 CNTRS AND FIXED WITH 65MM GAL BATTEN SCREWS. A 12MM GAP AT THE TOP OF THE WALL AND A 200MM GAP AT THE BOTTOM OF THE WALL MUST BE LEFT TO ALLOW AIRFLOW BEHIND THE TIMBER CLADDING. 50X50 HORIZONTAL BATTENS TO BE FIXED TO VERTICAL BATTENS AT 600 CNTRS WITH 65MM BATTEN SCREWS. ENSURE A GAP OF 8MM BETWEEN TIMBER CLADDING AND EDGE BATTEN. ALL DOORS TO BE INSTALLED TO MANUFACTURERES SPECS TIMBER CLADDING MUST NOT SIT ON TIMBER FRAME WATER PROOFING TO OVERHANG OVER DOOR FRAME APPROPRIATELY TO ENSURE CORRECT WATER RUNOFF AND PREVENT MOISTURE BUILD-UP. REFER TO DOOR SCHEDULE FOR DOOR AND GLAZING SPECIFICATIONS. ALL SOIL MUST SLOPE AWAY FROM BUILDING FOR A MINIMUM OF 1M. ALL OPENINGS ARE OF NOMINAL HEIGHT AND LENGTH AND MAY VARY. DOWNPIPES MUST BE INSTALLED IN ACCORDANCE WITH AS 3500. ALL OPENINGS ARE OF NOMINAL HEIGHT AND LENGTH AND MAY VARY. GAS METER AND METER BOX TO BE INSTALLED BY ELECTRICIAN CORRECTLY. REFER TO NOTES ON W05. FEATURE WALL AND STONE WALL AT THE FRONT OF THE PROPERTY AND ATTATCHED CUSTOM MAILBOX TO BE CONSTRUCTED OF ECO-OUTDOOR DRYSTONE 'ALPINE' WALL PANELS GLUED ON TOP OF 6MM FIBRE CEMENT SHEETING APPROPRIATELY FIXED TO A TIMBER WALL FRAMED WALL USING 30MM GAL CLOUTS. THE LOCATION EXTRA PEICES OF BATTEN TO BE ATTATCHED AT JOINTS TO FIX SHORTER PEICES OF CLADDING WHERE REQUIRED. 50X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS TO BE USED TO FIX 100X25MM TURPENTINE SHADOW CLADDING. IF NAILS ARE LESS THAN 30MM FROM THE END OF THE PEICE OF TIMBER, A PILOT HOLE MUST BE DRILLED PRIOR TO FIXING. END GRAIN TO BE SEALED AND INTERGRAIN REDWOOD STAIN TO BE APPLIED TO CLADDING AS PER MANUFACTURERES SPECS. SCHWEISS CUSTOM DESIGNED MECHANICAL DOORS INSLALLED TO MANUFACTURERES SPECIFICATIONS WITH 100X25 TURPENTINE CLADDING AND INTERGRAIN REDWOOD NATURAL STAIN. TO BE FIXED WITH 50MM GAL CLOUTS. ELECTRONIC MECHANICAL ARMS AND HYDROLICS SPECIFIED AND INSTALLED BY MANUFACTURERE. EXTERNAL CLADDING NOTES MECHANICAL GARAGE DOOR General Notes INDICTIVE POSITION OF 2500L RHEEM PREMIER® HILINE SOLAR HOT WATER HEATER GAS BOOSTED. MODEL: 52H180K/1S-G INSTALLED TO MANUFACTURERES SPECIFICATIONS ARTICULATE MASONRY VENEER WALLS MUST BE CONSTRUCTED IN ACCORDANCE WITH AS 3700 AND AS 1684.4. OF THIS WALL AND ASSOCIATED CURVE WILL BE INDICTIVE AND FOLLOW THE EDGE AND LENGTH OF THE DRIVEWAY AND THE FRONT OF THE PROPERTY EDGE UNTILL OT REACHES THE MAILBOX AND FENCE AND THEN CONTINUE UNTILL IT REACHES THE EASTERN FENCE. HEIGHT OF THE FENCE TO STAY LEVEL ALONG ITS LENGTH. FEATURE WALL TO BE CONSTRUCTED FROM ECO OUTDOOR DRYSTONE PANELS FOR CONSTRUCTION DETAILS SEE GENERAL NOTES. 20MPA CONCRETE DRIVEWAY 1 W08 2 W08 8 9 10 ALUCOBOND SPARKLING BLACK METALLIC 888 SEALED WITH BLACK SILICONE FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS SKYDOME LOW E DOUBLE GLAZED BLACK ALUMINIUM FRAME INSTALLED TO MANUFACTURERES SPECS COLOURBOND CORRGATED ROOFING IRON INSTALLED TO MANUFCTURERES SPECS 'MONUMENT' 90MM COLOURBOND LYSAGHT QUAD GUTTER 'MONUMENT' FIXED TO MANUFACTURERES SPECS DN 100 TYPE C METAL DOWNPIPE 'MONUMENT' LOW GLOSS FINISH 220mm X 140mm METAL RAINWATER HEAD FIXED TO CLADDING USING MANUFACTURERS SPEC COLOURBON IRON RIDGE CAPPING FIXED TO MANUYFACTURERES SPECIFICATIONS 'MONUMENT' 100X25 TURPENTINE CLADDING INTERGRAIN REDWOOD STAIN FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS ALUCOBOND SPARKLING BLACK METALLIC 888 SEALED WITH BLACK SILICONE FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS 90MM COLOURBOND LYSAGHT QUAD GUTTER 'MONUMENT' FIXED TO MANUFACTURERES SPECS DN 100 TYPE C METAL DOWNPIPE 'MONUMENT' LOW GLOSS FINISH 220mm X 140mm METAL RAINWATER HEAD FIXED TO CLADDING USING MANUFACTURERS SPECS HIGHGROVE 9MM TOUGHENED SAFETY GLASS 1200X1300X12 PANEL STAINLESS STEEL FIXING TO MANUFACTURERES SPECIFICATIONS SEE BALUSTRADE DETAIL ON W16 INDICTIVE POSITION OF PREMIUM LINE GERMAN SOLAR, SOLAR PANELS INSTALLED TO MANUFACTURERES SPECIFICATIONS INDICTIVE POSITION OF PHOTOVOLTAICS FOR SOLAR HOT WATER SYSTEM INSTALLED TO MANUFACTURERES SPECIFICATIONS INDICTIVE POSITION OF 2500L RHEEM PREMIER® HILINE SOLAR HOT WATER HEATER GAS BOOSTED. MODEL: 52H180K/1S-G INSTALLED TO MANUFACTURERES SPECS SKYDOME LOW E DOUBLE GLAZED BLACK ALUMINIUM FRAME INSTALLED TO MANUFACTURERES SPECS 100X25 TURPENTINE DECKING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL SELF DRILLING SCREWS . 19 21 2838 2869571 5567 FEATURE WALL TO BE CONSTRUCTED FROM ECO OUTDOOR DRYSTONE PANELS FOR CONSTRUCTION DETAILS SEE GENERAL NOTES. Scale Checked by Drawn by Date Project number 1 : 50 North/ South Elevations P1.0 FINCH STREET NEW DWELLING MR A AND MRS M METCALF Issue Date Author HALEN MOKA 24 FINCH STREET, BEECHWORTH VIC W07 PRODUCED BY AN AUTODESK STUDENT PRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT
  • 8.
    1 W09 ALL DOORS TOBE INSTALLED TO MANUFACTURERES SPECS TIMBER CLADDING MUST NOT SIT ON DOOR FRAME. WATER PROOFING TO OVERHANG OVER DOOR FRAME APPROPRIATELY TO ENSURE CORRECT WATER RUNOFF AND PREVENT MOISTURE BUILD- UP AND WATER INGRESS. REFER TO DOOR SCHEDULE FOR DOOR AND GLAZING SPECIFICATIONS. ALL STRUCTURAL STEEL TO BE PROTECTED IN ACCORDANCE WITH AS2312. ALL BRICKWORK TO BE CONSTRUCTED IN ACCORDANCE WITH AS4773 MASONRY IN SMALL BUILDINGS. FORMWORK FOR CONCRETE SLAB TO BE CONSTRUCTED IN ACCORDANCE WITH AS3610 FORMWORK FOR CONCRETE. RETAINING WALL TO BE BUILT IN ACCORDANCE WITH AS4678 EARTH RETAINING STRUCTURES. ALL STORMWATER GUTTERS, PIPES AND SERVICES TO BE CONSTRUCTED IN ACCORDANCE WITH ASNZS 3500.3 PASRT 3 STORMWATER DRAINAGE ALL CONCRETE STRUCTURES TO BE CONSTRUCTED IN ACCORDANCE WITH AS 3600 CONCRETE STRUCTURES. CONCRETE SLAB TO CONSTRUCTED IN ACCORDANCE WITH AS2870 RESIDENTIAL SLABS AND FOOTINGS. TIMBER CLADDING SPECIFICATIONS: WALL MUST BE SARKED AND EXTERNALLY FIXED WITH 6MM CEMENT SHEETING USING 30MM GAL CLOUTS. 20X50 VERTICAL TIMBER BATTENS TO BE PLACED AT 600 CNTRS AND FIXED WITH 65MM GAL BATTEN SCREWS. A 12MM GAP AT THE TOP OF THE WALL AND A 200MM GAP AT THE BOTTOM OF THE WALL MUST BE LEFT TO ALLOW AIRFLOW BEHIND THE TIMBER CLADDING. 50X50 HORIZONTAL BATTENS TO BE FIXED TO VERTICAL BATTENS AT 600 CNTRS WITH 65MM BATTEN SCREWS. ENSURE A GAP OF 8MM BETWEEN TIMBER CLADDING AND EDGE BATTEN. EXTRA PEICES OF BATTEN TO BE ATTATCHED AT JOINTS TO FIX SHORTER PEICES OF CLADDING WHERE REQUIRED. 50X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS TO BE USED TO FIX 100X25MM TURPENTINE SHADOW CLADDING. IF NAILS ARE LESS THAN 30MM FROM THE END OF THE PEICE OF TIMBER, A PILOT HOLE MUST BE DRILLED PRIOR TO FIXING. END GRAIN TO BE SEALED AND INTERGRAIN REDWOOD STAIN TO BE APPLIED TO CLADDING AS PER MANUFACTURERES SPECS. ALUCOBOND® PLUS SPECIFICATIONS: ALUCOBOND® PLUS ALUMINIUM COMPOSITE MATERIAL (ACM) SHALL BE 6MM THICK AND CONSIST OF 2 LAYERS OF 0.5MM THICK ALUMINIUM SANDWICHING A MINERAL FILLED FIRE RESISTANT CORE CONTAINING 70% NON COMBUSTIBLE MINERAL FILLING. THE ALUMINIUM SKINS SHALL BE OF ALLOY ALMG 1- NS41 (EN AW 5005A NEAREST EQUIVALENT) HAVING AN ULTIMATE STRENGTH OF 130 MPA AND 0.2% PROOF STRESS OF 90 MPA. ALUCOBOND SHEETING MUST BE FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS EVERY 100MM AROUND THE EDGES TO TIMBER BATTENS AND STUDS. BE SURE TO FIX EXTRA TIMBER PEICES AROUND ALUCOBOND EDGES WHERE THERE ARE GAPS AND NO TIMBER TO FIX TO. VELUX ROOF WINDOWS SPECIFICATIONS: VELUX ROOF WINDOWS AND MATERIALS THAT IT CONSISTS OF TO MEET THE REQUIREMENTS OF AS4285 SKYLIGHTS, AS1288 OVERHEAD GLAZING AND AS3959 BUSHFIRE FOR BAL 40 REQUIREMENTS AND AS1530.1 NON- COMBUSTIBILITY.. MUST BE INSTALLED TO MANUFACTURERES SPECIFICATIONS AND SEALED APPROPRIATELY TO ENSURE THERE IS NO WATER INGRESS. SEE DETAIL ON W16 CONCRETE SPECIFICATION: 300X300 INTERNAL BEAMS TO CONTAIN 3-L11TM REINFORCMENT STEEL 30MM FROM BOTTOM OF BEAM AND @ 6M MAX CTRS. GARAGE SLAB FFL 8864. 400X300 EXTERNAL EDGE BEAMS TO CONTAIN 3-L11TM REINFORCEMENT MESH 30MM FROM BOTTOM OF BEAM. CONCRETE MANUFACTURED MUST BE IN ACCORDANCE WITH AS3700 STANDARD CORE 13MM PLASTERBOARD TO BE FIXED ALONG WALLS STUDS AND 15MM FROM SHEET EDGES AND ENDS WITH 30MM 'W' TYPE PLASTERBOARD SCREWS. SERVIES MUST BE IN PLACE BEFORE INSTALLATION. ENSURE FRAMING IS PLUMB, LEVEL &SQUARE AND THAT THE AREA IS WEATHER PROOF. ENSURE THAT STUD SPACING TAKES INTO ACCOUNT THE WIDTH OF PLASTERBOARD SHEETS AND ALLOWS FIXING POINTS AT ITS EDGES. ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS. ALUCOBOND SPARKLING BLACK METALLIC 888 SEALED WITH BLACK SILICONE FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS COLOURBOND CORRGATED ROOFING IRON INSTALLED TO MANUFCTURERES SPECS 'MONUMENT' ALUCOBOND SPARKLING BLACK METALLIC 888 SEALED WITH BLACK SILICONE FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS COLOURBON IRON RIDGE CAPPING FIXED TO MANUYFACTURERES SPECIFICATIONS 'MONUMENT' 100X25 TURPENTINE DECKING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL CLOUTS 100X25 TURPENTINE CLADDING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL CLOUTS HIGHGROVE TOUGHENED SAFETY GLASS 1200X1300X12 PANEL STAINLESS STEEL FIXING TO MANUFACTURERES SPECIFICATIONS 25001855 lower floor level 1 level 2 higher floor 500 0 3000 4855 30001855 100X25 TURPENTINE CLADDING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL CLOUTS ROOFSPACE ROOFSPACE 90MM TIMBER STUD WALL WITH CHARCOAL NORSTONE ROCK PANEL CLADDING INSTALLED MANUFACTURERES SPECS.. 180X45 MGP10 RAFTER FIXED TO 35X90 MGP10 ROOF BATTENS @900MM CNTRS WITH 100X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS. BATTENS SHOULD BE FIXED WITH 3.1MMX90MM GAL SHANK NAILS @450MM CNTRS STANDARD CORE 13MM PLASTERBOARD TO BE FIXED ALONG WALLS STUDS AND 15MM FROM SHEET EDGES AND ENDS WITH 30MM 'W' TYPE PLASTERBOARD SCREWS. CEILING MUST HAVE PEER 16X6000MM 0.38BMT DOMESTIC CEILING BATTEN FCDB-60 @450 CNTRS INSTALLED TO MANUFACTURERES SPECS PRIOR TO FIXING PLASTERBOARD. ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS. STANDARD CORE 13MM PLASTERBOARD TO BE FIXED ALONG WALLS STUDS AND 15MM FROM SHEET EDGES AND ENDS WITH 30MM 'W' TYPE PLASTERBOARD SCREWS. DW STANDARD CORE 13MM PLASTERBOARD TO BE FIXED ALONG WALLS STUDS AND 15MM FROM SHEET EDGES AND ENDS WITH 30MM 'W' TYPE PLASTERBOARD SCREWS. 500MM FLOOR HEIGHT CHANGE. SEE DETAIL ON W16. 150MM CONCRETE SLAB TO BE CONSTRUCTED IN ACCORDANCE WITH AS2870 AND USING SL82 AS REINFORCEMENT MESH 30MM FROM TOP. R2.7 1160X580 HIGH PERFORMANCE GOLD BRADFORD INSULATION BATTS CUT TO FIT SECURED WITH 13MM STANDARD CORE PLASTERBOARD. 10 5 4 3 2 17 1 1 INTERNAL REINFORCED CONCRETE BEAM 300X300 GENERAL NOTES external cladding notes INTERNAL cladding notes 1 W09 ALUCOBOND SPARKLING BLACK METALLIC 888 SEALED WITH BLACK SILICONE FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS COLOURBOND CORRGATED ROOFING IRON INSTALLED TO MANUFCTURERES SPECS 'MONUMENT' ALUCOBOND SPARKLING BLACK METALLIC 888 SEALED WITH BLACK SILICONE FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS R2.7 1160X580 HIGH PERFORMANCE GOLD BRADFORD INSULATION BATTS CUT TO FIT SECURED WITH 13MM STANDARD CORE PLASTERBOARD. 100X25 TURPENTINE DECKING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL CLOUTS 100X25 TURPENTINE CLADDING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL CLOUTS HIGHGROVE TOUGHENED SAFETY GLASS 1200X1300X12 PANEL STAINLESS STEEL FIXING TO MANUFACTURERES SPECIFICATIONS 100X25 TURPENTINE CLADDING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL CLOUTS 180X45 MGP10 RAFTER FIXED TO 35X90 MGP10 ROOF BATTENS @900MM CNTRS WITH 100X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS. BATTENS SHOULD BE FIXED WITH 3.1MMX90MM GAL SHANK NAILS @450MM CNTRS STANDARD CORE 13MM PLASTERBOARD TO BE FIXED ALONG WALLS STUDS AND 15MM FROM SHEET EDGES AND ENDS WITH 30MM 'W' TYPE PLASTERBOARD SCREWS. CEILING MUST HAVE PEER 16X6000MM 0.38BMT DOMESTIC CEILING BATTEN FCDB-60 @450 CNTRS INSTALLED TO MANUFACTURERES SPECS PRIOR TO FIXING PLASTERBOARD. ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS. STANDARD CORE 13MM PLASTERBOARD TO BE FIXED ALONG WALLS STUDS AND 15MM FROM SHEET EDGES AND ENDS WITH 30MM 'W' TYPE PLASTERBOARD SCREWS. 500MM FLOOR HEIGHT CHANGE. SEE DETAIL ON W15. 150MM CONCRETE SLAB TO BE CONSTRUCTED IN ACCORDANCE WITH AS2870 AND USING SL82 AS REINFORCEMENT MESH 30MM FROM TOP. INTERNAL REINFORCED CONCRETE BEAM 300X300 100X25 TURPENTINE CLADDING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL CLOUTS 18 9 14 20 17 EXTERNAL REINFORCED CONCRETE BEAM 300X400 6MM FIBRE CEMENT SHEETING FIXED TO 2X180X45MM MGP10 RAFTERS W/ 50MM GAL CLOUTS lower floor level 1 0 3700 3700 higher floor 500 LEVEL 1 3200 300MM MGP10 STUD WALL. 500MM HIGH WITH 13MM STANDARD CORE PLASTERBOARD PAINTED 'NATURAL WHITE' Scale Checked by Drawn by Date Project number 1 : 100 Sections P1.0 FINCH STREET NEW DWELLING MR A AND MRS M METCALF Issue Date Author HALEN MOKA 24 FINCH STREET, BEECHWORTH VIC W08 1 : 100 Section 3 1 1 : 100 Section 5 2 PRODUCED BY AN AUTODESK STUDENT PRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT
  • 9.
    1 W08 2 W08 90MM STUD WALLWITH 80MM INSULATION BATTS. 6MM FIBRE CEMENT SHEETING TO BE FIXED TO STUDS OVER WATER PROOFING MEMBRANE. 20X50MM VERTICAL BATTENS TO BE FIXED TO CEMENT SHEETING AND 50X50MM HORIZONTAL BATTENS TO BE FIXED TO VERTICAL BATTENS. SEE GENERAL NOTES FOR CONSTRUCTION METHODS. COLOURBOND CORRGATED ROOFING IRON INSTALLED TO MANUFCTURERES SPECS 'MONUMENT' 200X38MM TURPENTINE FASCIA BOARD FIXED W/50MM GAL FLATHEAD NAILS COLOURBON IRON RIDGE CAPPING FIXED TO MANUYFACTURERES SPECIFICATIONS 'MONUMENT' 100X25 TURPENTINE DECKING INTERGRAIN REDWOOD STAIN FIXED WITH 50MM GAL SELF-DRILLING SCREWS SEE DECKING DETAIL ON W15 ALUCOBOND SPARKLING BLACK METALLIC 888 SEALED WITH BLACK SILICONE FIXED WITH B20620 IMPULSE C15 BFP STRAIGHT BRADERS 90MM COLOURBOND LYSAGHT QUAD GUTTER 'MONUMENT' FIXED TO MANUFACTURERES SPECS DN 100 TYPE C U-PVC DOWNPIPE 'MONUMENT' LOW GLOSS FINISH 220mm X 140mm METAL RAINWATER HEAD FIXED TO CLADDING USING MANUFACTURERS SPECS 100X25 TURPENTINE DECKING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED FIXED WITH 50MM GAL SELF-DRILLING SCREWS SEE DECKING DETAIL ON W15 HIGHGROVE TOUGHENED SAFETY GLASS 1200X1300X12 PANEL STAINLESS STEEL FIXING TO MANUFACTURERES SPECIFICATIONS SEE W15. INDICTIVE POSITION OF PREMIUM LINE GERMAN SOLAR, SOLAR PANELS INSTALLED TO MANUFACTURERES SPECIFICATIONS INDICTIVE POSITION OF PHOTOVOLTAICS FOR SOLAR HOT WATER SYSTEM INSTALLED TO MANUFACTURERES SPECIFICATIONS INDICTIVE POSITION OF 2500L RHEEM PREMIER® HILINE SOLAR HOT WATER HEATER GAS BOOSTED. MODEL: 52H180K/1S-G INSTALLED TO MANUFACTURERES SPECIFICATIONS SKYDOME LOW E DOUBLE GLAZED BLACK ALUMINIUM FRAME INSTALLED TO MANUFACTURERES SPECS AND SEALED APPROPRIATELY 100X25 TURPENTINE CLADDING INTERGRAIN REDWOOD STAIN FIXED WITH 50MM GAL SELF DRILLING SCREWS 150MM CONCRETE SLAB TO BE CONSTRUCTED IN ACCORDANCE WITH AS2870 AND USING SL82 AS REINFORCEMENT MESH 30MM FROM TOP. 300MM TIMBER FRAMED PARTITION WALL WITH 13MM PLASTERBOARD LINING 2x240x45 MGP12 RIDGEBOARD FIXED W/ PRYDA 100X35X1.0MM MULTIGRIP BRACKET AND 50MM GAL NAILS 35X90 MGP10 ROOF BATTENS @450MM SPACES FIXED WITH 3.1MMX90MM GAL SHANK NAILS PEER 16X6000MM 0.38BMT DOMESTIC CEILING BATTEN FCDB-60 @450 CNTRS TO BE INSTALLED TO MANUFACTURERES SPECS HIGHGROVE TOUGHENED SAFETY GLASS 1200X1300X12 PANEL STAINLESS STEEL FIXING TO MANUFACTURERES SPECIFICATIONS GENERAL NOTES ALL DOORS TO BE INSTALLED TO MANUFACTURERES SPECS TIMBER CLADDING MUST NOT SIT ON TIMBER FRAME WATER PROOFING TO OVERHANG OVER DOOR FRAME APPROPRIATELY TO ENSURE CORRECT WATER RUNOFF AND PREVENT MOISTURE BUILD-UP. REFER TO DOOR SCHEDULE FOR DOOR AND GLAZING SPECIFICATIONS. ALL STRUCTURAL STEEL TO BE PROTECTED IN ACCORDANCE WITH AS2312. ALL BRICKWORK TO BE CONSTRUCTED IN ACCORDANCE WITH AS4773 MASONRY IN SMALL BUILDINGS. FORMWORK FOR INSITU CONCRETE WALL TO BE CONSTRUCTED IN ACCORDANCE WITH AS3610 FORMWORK FOR CONCRETE. RETAINING WALL TO BE BUILT IN ACCORDANCE WITH AS4678 EARTH RETAINING STRUCTURES. ALL STORMWATER GUTTERS, PIPES AND SERVICES TO BE CONSTRUCTED IN ACCORDANCE WITH ASNZS 3500.3 PASRT 3 STORMWATER DRAINAGE ALL CONCRETE STRUCTURES TO BE CONSTRUCTED IN ACCORDANCE WITH AS 3600 CONCRETE STRUCTURES. CONCRETE SLAB TO CONSTRUCTED IN ACCORDANCE WITH AS2870 RESIDENTIAL SLABS AND FOOTINGS. 90MM COLOURBOND LYSAGHT QUAD GUTTER 'MONUMENT' FIXED TO MANUFACTURERES SPECS DN 100 TYPE C U-PVC DOWNPIPE 'MONUMENT' LOW GLOSS FINISH 220mm X 140mm METAL RAINWATER HEAD FIXED TO CLADDING USING MANUFACTURERS SPEC 200X38MM TURPENTINE FASCIA BOARD FIXED W/50MM GAL FLATHEAD NAILS 200X125MM STEEL RHS INSTALLED AND FIXED TO ENGINEERS SPECS PRYDA 130X90MM HEAVY DUTY GAL STEEL STIRRUP POST ANCHOR 200X200X500 CONCRETE FOOTING 90MM TIMBER STUD WALL WITH CHARCOAL NORSTONE ROCK PANEL CLADDING INSTALLED MANUFACTURERES SPECS.. 150X100UA10 STEEL ANGLE BEAM TO BE INSTALLED TO ENGINEERS SPECS SLIDING DOOR TO BE INSTALLED TO MANUFACTURERES SPECS external cladding NOTES WALL MUST BE SARKED AND EXTERNALLY FIXED WITH 6MM CEMENT SHEETING USING 30MM GAL CLOUTS. 20X50 VERTICAL TIMBER BATTENS TO BE PLACED AT 600 CNTRS AND FIXED WITH 65MM GAL BATTEN SCREWS. A 12MM GAP AT THE TOP OF THE WALL AND A 200MM GAP AT THE BOTTOM OF THE WALL MUST BE LEFT TO ALLOW AIRFLOW BEHIND THE TIMBER CLADDING. 50X50 HORIZONTAL BATTENS TO BE FIXED TO VERTICAL BATTENS AT 600 CNTRS WITH 65MM BATTEN SCREWS. ENSURE A GAP OF 8MM BETWEEN TIMBER CLADDING AND EDGE BATTEN. EXTRA PEICES OF BATTEN TO BE ATTATCHED AT JOINTS TO FIX SHORTER PEICES OF CLADDING WHERE REQUIRED. 50X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS TO BE USED TO FIX 100X25MM TURPENTINE SHADOW CLADDING. IF NAILS ARE LESS THAN 30MM FROM THE END OF THE PEICE OF TIMBER, A PILOT HOLE MUST BE DRILLED PRIOR TO FIXING. END GRAIN TO BE SEALED AND INTERGRAIN REDWOOD STAIN TO BE APPLIED TO CLADDING AS PER MANUFACTURERES SPECS. FEATURE WALL AND STONE WALL AT THE FRONT OF THE PROPERTY AND ATTATCHED CUSTOM MAILBOX TO BE CONSTRUCTED OF ECO-OUTDOOR DRYSTONE 'ALPINE' WALL PANELS GLUED ON TOP OF 6MM FIBRE CEMENT SHEETING APPROPRIATELY FIXED TO A TIMBER WALL FRAMED WALL USING 30MM GAL CLOUTS. THE LOCATION OF THIS WALL AND ASSOCIATED CURVE WILL BE INDICTIVE AND FOLLOW THE EDGE AND LENGTH OF THE DRIVEWAY AND THE FRONT OF THE PROPERTY EDGE UNTILL OT REACHES THE MAILBOX AND FENCE AND THEN CONTINUE UNTILL IT REACHES THE EASTERN FENCE. HEIGHT OF THE FENCE TO STAY LEVEL ALONG ITS LENGTH. SERVICES MUST BE IN PLACE BEFORE INSTALLATION. ENSURE FRAMING IS PLUMB, LEVEL &SQUARE AND THAT THE AREA IS WEATHER PROOF. ENSURE THAT STUD SPACING TAKES INTO ACCOUNT THE WIDTH OF PLASTERBOARD SHEETS AND ALLOWS FIXING POINTS AT ITS EDGES. STANDARD CORE 13MM PLASTERBOARD TO BE FIXED ALONG WALLS STUDS AND 15MM FROM SHEET EDGES AND ENDS WITH 30MM 'W' TYPE PLASTERBOARD SCREWS . CEILING MUST HAVE PEER 16X6000MM 0.38BMT DOMESTIC CEILING BATTEN FCDB-60 @450 CNTRS INSTALLED TO MANUFACTURERES SPECS PRIOR TO FIXING PLASTERBOARD. ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS. INTERIOR FEATURE WALL TO BE A 90MM TIMBER STUD WALL WITH CHARCOAL NORSTONE ROCK PANEL CLADDING INSTALLED TO MANUFACTURERES SPECS.. WALL TO RUN THE LENGTH OF THE HOUSE. FINISHED FLOOR SURFACE ALONG HALLWAY TO BE CONSTRUCTED OF POLISHED CONCRETE. LIVING SPACES INCLUDING BEDROOMS, KITCHEN ,LIVING ROOM AND DINING TO BE 100X25 TURPENTINE SHIPLAP TIMBER FLOORING WITH NATURAL STAIN. FOR LOCATION OF FLOOR TYPES AND AREA SEE W10. BATHROOMS AND LAUNDRY FLOORS TO BE TILED WITH GLAZED POPAR LIGHT GREY BEAUMONT FLOOIRING TILES WITH A LIGHT GREY MORTAR. WATERPROOFING TO OCCUR IN THESE AREAS APPROPRIATELY. SEE WET AREA DETAIL ON W15. INTERNAL LINING NOTES 19 20 17 SEE INTERNAL ELEVATION 124.04° 152.21° 96.92° PARTITION WALL AND SHELVING 90MM TIMBER FRAMED STUD WALL WITH 13MM PLASTERBOARD. REF Scale Checked by Drawn by Date Project number As indicated Sections II P1.0 FINCH STREET NEW DWELLING MR A AND MRS M METCALF Issue Date Author HALEN MOKA 24 FINCH STREET, BEECHWORTH VIC W09 PRODUCED BY AN AUTODESK STUDENT PRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT
  • 10.
    MASTER BEDROOM ENSUITE WIR DOUBLE GARAGE STORAGE LIVINGKITCHEN DINING BATH LAUNDRY BED 1 BED 2 STUDY DECKING 2 1 FFL400 FFL1190 UP OVERHEAD ROOF LINE SL SL SL SL SL SL SL LEGEND ELECTRICAL CABLES TYPE A TYPE B TYPE E TYPE C SMOKE ALARM TYPE D DOUBLE GENERAL POWER OUTLET 1 POINT LIGHT SWITCH 2 POINT LIGHT SWITCH 3 POINT LIGHT SWITCH METERBOX DOUBLE GENERAL POWER OULET TELEPHONE CONNECTION POINT TELEVISION POINT ST RH REF PTY DW WMDR N O RTH SMOKE DETECTORS TO BE INSTALLED IN ACCORDANCE WITH AS 3786-1993 ALL ELECTRICAL INSTALLATION MUST MEET THE REQUIREMENTS OF AS 3000. SMOKE ALARMS LOCATED AT THE FRONT END OF THE HALLWAY, THE END OF THE HALLWAY AND NEAR THE DOOR TO THE GARAGE IN THE LIVING ROOM. EXACT POSITIONING TO COMPLY WITH BCA CL: 3.7.2.3 ALL ELECTRICAL WORKS TO BE CONDUCTED BY A REGISTERED ELECTRIAN. LIGHTING FIXTURES AND LOCATIONS MUST BE INSTALLED IN ACCORDANCE WITH AS1680. MECHANICAL VENTILATION TO COMPLY WITH AS1668. General Notes TYPE: A QUANTITY: 9 MINIWOODY LED 42W FACADE LAMP LED SPOT LAMP FOR CEILING/WALL MOUNTED SPOT LIGHTING. TYPE: B QUANTITY: 57 LEDLUX 14W 92MM NON-DIMMABLE CNC ALUMINIUM ROUND DOWN LIGHT. CEILING MOUNTED DOWNLIGH FOR AMBIENT LIGHTING. TYPE: C QUANTITY: 4 T5 STARCOAT 80W LINEAR FLUROSCENT LAMP FOR CEILING MOUNTED GARAGE LIGHTS. TYPE: D QUANTITY: 8 THERMALITE DELUXE 3 IN 1 BATHROOM HEATER 4X275W HEAT LAMPS. STAINLESS STEEL HOUSING WITH BUILT IN EXHAUST AND HEAT LAMPS. TYPE: E QUANTITY: 59 HPM 12V 0.3W LED DECK LIGHTS. RECESSED DECKING LIGHTS AND PERIMETER POOL LIGHTING. SMOKE ALARM TYPE: WORMWALD TYCO 614P PHOTOELECTRIC SMOKE DETECTOR. LIGHTING TYPES ELECTRICAL CONTRACTOR TO BE SOLELY RESPONSIBLE FOR FOR STRICT COMPLIANCE WITH ALL SAFETY STANDARDS, REGULATIONS AND AUTHORITY REGULATIONS. CONTRACTOR REQUIRED TO ENSURE ALL ELECTRICAL WORK TO BE TESTED BY THE RESPINSOBLE ELECTRICAL SUPPLY AUTHORITY AFTER THE COMPLETETION AND INSTALLTION OF ALL WORKS INVOLVED. ANY CERTIFICATES, PERMITS AND APPROVALS ARE TO BE FOWARDED TO OWNER AS THEY ARE RECIEVED. UNLESS OTHERWISE NOTED ALL GPO'S TO BE FLAT 3 PIN TYPE. SEE DRAWING FOR LOCATIONS. ALL GPO'S EXCEPT FOR BENCHTOP GPO'S TO BE FIXED AT 300MM ABOVE FFL. BENCH TOP GPO'S TO BE FIXED 300 ABOVE BENCHTOP. PH PH PH PH PH Scale Checked by Drawn by Date Project number 1 : 100 Electrical Plan P1.0 FINCH STREET NEW DWELLING MR A AND MRS M METCALF Issue Date Author HALEN MOKA 24 FINCH STREET, BEECHWORTH VIC W10 PRODUCED BY AN AUTODESK STUDENT PRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT
  • 11.
    MASTER BEDROOM ENSUITEWIR DOUBLE GARAGE STORAGE LIVINGKITCHEN DINING BATH LAUNDRY BED 2 STUDY ROOF LINE SL SL SL SL SL SL SL LEGEND SKYLIGHT SMOKE ALARM TYPE A TYPE B TYPE C TYPE D CEILING PITCH CHANGE INDICTIVE LOCATION OF MANHOLE SL PTY WMDR N O RTH SL SL ROOF LINE CEILINGPITCHCHANGE CEILINGPITCHCHANGE SMOKE DETECTORS TO BE IN ACCORDANCE WITH AS 3786-1993. ALL ELECTRICAL WORKS AND INSTALLATION TO BE CONDUCTED BY A REGISTERED ELECTRIAN AND IN ACCORDANCE WITH AS/NZS3000. LIGHTING FIXTURES AND LOCATIONS MUST BE INSTALLED IN ACCORDANCE WITH AS1680. ALL INTERIOR LIGHTING MUST COMPLY WITH AS/NZS 1680.1 INTERIOR LIGHTING PART 1 GENERAL PRINCIPLES. ALL CEILINGS TO BE 13MM STANDARD CORE PLASTERBOARD. CEILING MUST HAVE PEER 16X6000MM 0.38BMT DOMESTIC CEILING BATTEN FCDB-60 @450 CNTRS INSTALLED TO MANUFACTURERES SPECS PRIOR TO FIXING PLASTERBOARD. ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS. SERVICES MUST BE IN PLACE BEFORE PLASTERBOARD INSTALLATION. ENSURE FRAMING IS PLUMB, LEVEL &SQUARE AND THAT THE AREA IS WEATHER PROOF. ENSURE THAT CEILING BATTEN SPACING TAKES INTO ACCOUNT THE WIDTH OF PLASTERBOARD SHEETS AND ALLOWS FIXING POINTS AT ITS EDGES. STANDARD CORE 13MM PLASTERBOARD TO BE FIXED ALONG CEILING BATTENS AND 15MM FROM SHEET EDGES AND ENDS WITH 30MM 'W' TYPE PLASTERBOARD SCREWS . TYPE: A QUANTITY: 9 MINIWOODY LED 42W FACADE LAMP LED SPOT LAMP FOR CEILING/WALL MOUNTED SPOT LIGHTING. TYPE: B QUANTITY: 57 LEDLUX 14W 92MM NON-DIMMABLE CNC ALUMINIUM ROUND DOWN LIGHT. CEILING MOUNTED DOWNLIGH FOR AMBIENT LIGHTING. TYPE: C Quantity: 4 T5 STARCOAT 80W LINEAR FLUROSCENT LAMP FOR CEILING MOUNTED GARAGE LIGHTS. TYPE: D Quantity: 8 THERMALITE DELUXE 3 IN 1 BATHROOM HEATER 4X275W HEAT LAMPS. STAINLESS STEEL HOUSING WITH BUILT IN EXHAUST AND HEAT LAMPS. SMOKE ALARM TYPE: WORMWALD TYCO 614P PHOTOELECTRIC SMOKE DETECTOR. General Notes ROOFLINE FIXED CEILING LIGHTING TYPES MH MH MH MH Scale Checked by Drawn by Date Project number 1 : 100 Reflected Ceiling Plan P1.0 FINCH STREET NEW DWELLING MR A AND MRS M METCALF Issue Date Author HALEN MOKA 24 FINCH STREET, BEECHWORTH VIC W11 PRODUCED BY AN AUTODESK STUDENT PRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT
  • 12.
    MASTER BEDROOM 4m X4.7m CARPET ENSUITE 4m X 3.4m TILES WIR 4m X 1.3m CARPET DOUBLE GARAGE 6.7m X 4.2m CONCRETE STORAGE 0.8m X 3.1m CONCRETE LIVING 7m X 4.3m FLOORBOARDS KITCHEN 7.2m X 5m FLOORBOARDS DINING 4.4m X 4.2m FLOORBOARDS BATH 1.9m X 4.7m TILES LAUNDRY 4.7m X 1.5m TILES BED 1 3.4m X 4.7m CARPET BED 2 4.3m X 4.7m CARPET STUDY 2.5m X 4.7m FLOORBOARDS 100X25 TURPENTINE DECKING INTERGRAIN REDWOOD 'NATURAL' STAIN AND TO COMPLY WITH APPENDIX E OF AS 3959 2009. 24m 2 400 1190 950 950 650 2920 260 3120 260 1020 800 1935 400 1930 400 655 260 1640836021510 31510 11040 260 3120 260 7140 260 1530 5260 260 3990 250 1280 720 605 2550 600 795 1567036608830 5555252855251690140519517301720173065517303825525280525427552543653690760 2 1 FFL400 FFL1190 7180872 16503320 4385 915 900 3230 1205 2646 2965 1960 2195 1820 1755 1310 1 2 3 4 5 6 7 8 9 10 11 14 12 13 15 16 17 18 19 20 1 2 4 5 6 7 8 9 3016 UP CONCRETE FLOORING POLISHED FINISH TILED FLOORING OVERHEAD ROOF LINE SL SL SL SL SL SL SL SL SL CW5 ST RH REF PTY DW WMDR N O RTH 1 W08 1 W09 2 W08 OVERHEADBEAM STRUCTURAL COLUMN 300MM PARTITION WALL EJ EJ POOL GATE TO OPEN AWAY FROM POOL WITH SELF CLOSING SAFETY LATCH 1500MM HIGH MIN. OVERHEADWINDOW 9 10 12 GENERAL NOTES DECKING NOTES: DECKING TO BE MADE OF 130X30 TURPENTINE DECKING WITH 3MM GAP AND FIXED WITH 50MM SELF DRILLING STAINLESS STEEL SCREWS. TIMBER POSTS TO BE 100X100 TURPENTINE POSTS ON 100MM GAL STIRRUPS WITH TERMITE CAPPING. TURPENTINE DECKING TO BE STAINED WITH INTERGRAIN REDWOOD STAIN TO MANUFACTURERES SPECIFICATIONS. DECKING MATERIAL AND INSTALLATION TO COMPLIE WITH THE REQUIREMENTS FOR BAL12.5 AS STATED IN AS 3959. STAIRS TO BE CONSTRUCTED FROM 20MPA CLASS 1 FINISH CONCRETE. BRICK VENNER WALLS TO BE CONSTRUCTED IN ACCORDANCE WITH AS 3700-2001 Section 12 INTERIOR LINING OF ALL WALLS TO BE 13MM PLASTERBOARD NATURAL WHITE COLOUR. EXCLUDING GARAGE INTERIOR WALLS. REFER TO MANUFACTURER FOR INSTALLATION AND W06 AND W07 INTERNAL CLADDING NOTES. SMOKE ALARMS LOCATED AT THE FRONT END OF THE HALLWAY, THE END OF THE HALLWAY AND NEAR THE DOOR TO THE GARAGE IN THE LIVING ROOM. EXACT POSITIONING TO COMPLY WITH BCA CL: 3.7.2.3 DOWNPIPE SPECS ARE SHOWN IN DETAIL ON WO6 AND WO7 ELEVATIONS AND IN PLAN ON W05 ROOF PLAN. ALL WINDOW AND DOOR SIZES ARE NOMINAL. SPECIFICATIONS ARE SHOWN ON W01 DOOR AND WINDOW SCHEDULE. REFER TO ENGINEERS SPECIFICATIONS FOR STEEL CONSRUCTION. MECHANICAL VENTILATION TO COMPLY WITH AS1668. CARPET AND TILES IS TO BE INSTALLED TO MANUFACTURERS SPECIFICATIONS. INTERIOR WALLS ARE 90MM STUD WALLS EXCEPT FOR THE WALLS SEPERATING THE GARAGE FROM THE LIVING ROOM AND HALLWAY. AND TO BE CONSTRUCTED IN ACCORDANCE WITH AS 1684.4. ALL EXTERNAL WALLS ARE TO HAVE 10MM X 38MM THERMABLOK STRIPS INSTALLED ON THE INTERNAL SIDE OF THE STUD UNDERNEATH THE 13MM PLASTERBOARD. REFER TO MANUFACTURERS SPECS. FOR EXTERIOR WALL EXTERNAL LININGS REFER TO W06 AND W07 FOR EXACT POSITIONING OF CABINETRY REFER TO W14 AND W15 CUSTOM WINDOWS ARE TO BE INSTALLED TO MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE ITH AS 2047. SANITARY COMPARTMENTS TO BE IN ACCORDANCE WITH B.C.A, DOOR TO BE EITHER REMOVABLE IF LESS THAN 1200mm BETWEEN TOILET AND DOOR OR MUST OPEN OUTWARDS. ALL FLOOR WET AREAS ARE TO BE PROVIDED WITH IMPERVIOUS COVERINGS EXCEPT FOR THE KITCHEN. WALLS OF SHOWER AND AROUND BATH ARE TO BE IMPERVIOUS COVERINGS ALSO OR TILES OR GLASS. METER BOX TO BE INSTALLED:STAINLESS STEEL 18 POLE SINGLE PHASE METER BOX MODEL RS4852 WIRE, HALF DUPLEX , ISOLATED. GARAGE WALLS ARE 240MM FIRE RATED BRICK VENEER WALLS AND TO BE CONSTRUCED IN ACCORDANCE WITH AS 3700 AND AS1684.4. INTERNAL STAIRS AND FLOORBOARDS TO BE MADE OF CAMBIA AWA SHIPLAP 18MM TIMBER FLOORING INSTALLED TO MANUF'S SPECS. TIMBER DECKING TO BE 100X25 TURPENTINE DECKING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL SELF DRILLING SCREWS AND TO COMPLY WITH APPENDIX E OF AS 3959 2009. SWIMMING POOL TO BE SELECTED BY CLIENT AND INSTALLED BY CERIFIED POOL CONTRACTORS TO THE APPROPRIATE AND REQUIRED SAFETY REGULATIONS. LEGEND SPOT ELEVATION SKYLIGHT SMOKE ALARM EXHAUST FAN DOWN PIPE 260MM BRICK VENEER WALL 325MM PRECAST CONCRETE WALL 90MM TIMBER STUD WALL DOOR TAG WINDOW TAG CUSTOM WINDOW TAG GLASS BALUSTRADE 1000 SL PTY PANTRY DW DISHWASHER WM WASHING MACHINE ST STOVE REF REFRIDGERATOR RH RANGEHOOD METER BOX EXPANSION JOINT 6 6 CW1 EJ Scale Checked by Drawn by Date Project number 1 : 100 Floor Plan P1.0 FINCH STREET NEW DWELLING MR A AND MRS M METCALF Issue Date Author HALEN MOKA 24 FINCH STREET, BEECHWORTH VIC W12 PRODUCED BY AN AUTODESK STUDENT PRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT
  • 13.
    GENERAL NOTES LEGEND GARAGE SLAB LOWERSLAB SECTION HIGHER SLAB SECTION REBATE RE-ENTRANT BARS EDGE BEAMS N O RTH 300X300 INTERNAL BEAMS TO CONTAIN 3-L11TM REINFORCMENT STEEL 30MM FROM BOTTOM OF BEAM AND @ 6M MAX CTRS. GARAGE SLAB FFL 8864 400X300 EXTERNAL EDGE BEAMS TO CONTAIN 3-L11TM REINFORCEMENTMESH 30MM FROM BOTTOM OF BEAM. CONCRETE MANUFACTURED MUST BE IN ACCORDANCE WITH AS3700 3-L11TM RE-ENTRANT BARS MUST BE IMPLEMENTED INTO THE SLAB @30MM OF THE TOP OF THE SLAB. 200MM OVERLAP MUST OCCUR WHERE HOUSE SLAB MEETS THE LOWERGARAGE SLAB. CONCRETE SLAB TO BE CONSTRUCTED IN ACCORDANCE WITH AS2870 AND USING SL82 AS REINFORCEMENT MESH 30MM FROM TOP. FORMWORK FOR CONCRETE SLAB TO BE CONSTRUCTED IN ACCORDANCE WITH AS3610 FORMWORK FOR CONCRETE. SLAB MUST BE CURED FOR 7 DAYS AND APPROVED BY A REGISTERED BUILDING SURVEYOR. SOIL CLASSIFICATION IS: CLASS M M RE-ENTRANT BARS AT INTERNAL CORNERS OF THE SLAB IN ACCORDANCE WITH BCA CL 3.2.5.3 NTERNAL REINFORCED CONCRETE BEAM 300X300 EXTERNAL REINFORCED CONCRETE EDGE BEAM 400X300 SLAB STEP DOWN OF 250MM REFER TO DETAIL 400 GARAGE SLAB 650 1180 STEP DOWN OF125MM REFER TO DETAIL 150MM REBATE TO ALLOW FOR BRICK VENEER CONSTRUCTION Scale Checked by Drawn by Date Project number 1 : 100 Slab Plan P1.0 FINCH STREET NEW DWELLING MR A AND MRS M METCALF Issue Date Author HALEN MOKA 24 FINCH STREET, BEECHWORTH VIC W13 PRODUCED BY AN AUTODESK STUDENT PRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT
  • 14.
    . .600 942 1190 1206 710710 710 710 1414262 981 1190 1206 SB RH ST 1 W14 3 W14 4 W14 REF OV PTY 1206 3024 571 3418 2646772 53417451203902422466 12701162 3251 669914 610330321725 9097 2197 132 485 4 9 8 130x14MM SPOTTED GUM OVERLAY FLOORBOARDS DW SHELVING WINERACKS 772 447 1143 1295 92 1203 1745 515 295 525 399 2441 90 1343 525 278 525 812 320 1174 806 1894 806 2545 1190 1070 OV REF ST RH SK 14491526 9 8 4 1417762442 914914914 914 1190 1190 1190 253 1190 1190 589 SBSK PB STACKABLE MAGNUM WINERACKS Scale Checked by Drawn by Date Project number As indicated Internal Elevations P1.0 FINCH STREET NEW DWELLING MR A AND MRS M METCALF Issue Date Author HALEN MOKA 24 FINCH STREET, BEECHWORTH VIC W14 1 : 50 Section 6 1 1 : 50 Internal Plan Kitchen 2 1 : 50 Section 7 3 1 : 50 Section 8 4 KITCHEN INTERNAL ELEVATIONS KITCHEN INTERNAL PLAN SKYLIGHTS: SKYDOME VELUX/VSE LOW E DOUBLE GLAZED BLACK ALUMINIUM FRAME INSTALLED, SEALED AND WATERPROOFED TO MANUFACTURERES SPECS. SPLASHBACK: DARK SLATE GLASS SPLASHBACK RANGEHOOD 24" ISLAND RANGEHOOD STAINLESS STEEL ROUND CHIMNEY KA-123- CS. KITCHEN WALL X8 KABOODLE 1200MM 2 DOOR WHITE WALL HUNG CABINET. HUNG CABINETS: W/SILVER ANODISED ALUMINIUM 'G' STYLE GRIP HANDLES. KITCHEN BASE X3 KABOODLE 710MM 4 DRAWER WHITE BASE CABINET CABINETS: X3 KABOODLE 710MM 3 DRAWER WHITE BASE CABINET W/SILVER ANODISED ALUMINIUM 'G' STYLE GRIP HANDLES. 19MM MOISTURE RESISTANT NATURAL WHITE MELAMINE PARTICLE BOARD WITH HIGH GLOSS FINISH. ENSURE CABINETRY IS FIXED AND LEVELED TO PREVENT DOORS FROM SWINGING OPEN UNINTENTIONALLY AND TO CREATE AN EVEN FIX WITH THE COUNTERTOP. ALL WALL HUNG CABINETS MUST BE FIXED USING THE PROVIDED WALL ANCHORS AND SCREWS TO THE WALL STUDS. REFRIDGERATOR: JENN-AIR 25.02 CU. FT. SIDE-BY-SIDE REFRIDGERATOR STAINLESS STEEL. OVEN: KITCHENAID 30" SINGLE ELECTRIC WALL OVEN STAINLESS STEEL. MUST BE INSTALLED BY CERTIFIED ELECTRICIAN. PANTRY 1300MM BEDFORD 2 DOOR WHITE FREESTANDING PANTRY MUST BE INSTALLED TO MANUFACTURERES SPECIFICATIONS FLOORBOARDS: 130X14MM NSW SPOTTED GUM CLASS 1 DURABILITY FLOORBOARDS. DURBAILITY: CLASS 1 GRADE: STANDARD AND BETTER COLOUR: WARM LENGTHS: RANDOM LENGTHS OF 0.4M-2.4M. NOTES: FLOORBOARDS TO BE GLUED OVER 19MM PARTICAL BOARD SUBFLOOR CEASAR STONE:. KITCHEN COUNTERTOP TO BE OSPREY CEASERSTONE W/PENCIL ROUNDED EDGES. KITCHEN TAP: X2 GESSI OXYGENE PULL OUT SPRAY KITCHEN MIXER BLACK SPOUT KITCHEN SINK: X2 SCHOCK STONE DOUBLE BOWL UNDERMOUNT KITCHEN SINK BLACK. COOKTOP: KITCHENAID 40" GAS COOKTOP- STAINLESS STEEL MUST BE INSTALLED BY CERTIFIED ELECTRICIAN.. SHELVING: CHICAGO 8 BOX 1200MM TIMBER SHELVING BY BLUE DOT. INSTALLED TO MANUFACTURERES SPECIFICATIONS. DISHWASHER: TO BE SELECTED BY CLIENT INSTALLED BY CERTIFIED PLUMBER OVEN AND COOKTOP TO BE CONNECTED AND INSTALLED BY A REGISTERED ELECTRICIAN TO MANUFACTURERES SPECIFICATIONS. DISHWASHER, BASINS AND TAPWARE TO BE INSTALLED BY REGISTERED PLUMBER. WINERACKS ARE FREE STANDING AND STACKABLE AND ARE NOT TO BE FIXED TO EACHOTHER, THE FLOOR OR THE WALL. SHELVING TO BE SINTALLED TO MANUFACTURERES SPECIFICATIONS. ALL WALLS TO BE PAINTED WITH DULUX NATURAL WHITE PAINT. DURING INSTALLATION OF SPLASHBACK THE SURFACE AREA MUST BE CLEAN AND ALL WALL FIXINGS MUST BE FLUSH OR RECESSED INTO THE WALL., A 6MM GAP MUST BE LEFT WHERE PANELS MEET AT ANY CORNERS AND AT EACH END. A 3MM GAP MUST ALSO BE LEFT WHERE PANELS MEET AND WHERE THE PANEL ABUTTS OVERHEAD CUPBOARDS OR WINDOW OPENINGS. ENSURE THE WALL IS PAINTED THE SAME COLOUR AS THE PANEL WHERE SHEETS MEET. PANEL MUST BE FIXED WITH DOUBLE SIDED TAPE AND A 6MM BEAD OF ADHESIVE APPLIED IN A WAVE FORMATION ON THE UNDERSIDE OF THE PANEL. EDGES WHERE COUNTERTOP MEETS SPLASHBACK AND AROUND KITCHEN BASIN TO BE SEALED AND WATERPROOFED. 90MM PARTITION WALL PAINTED NATURAL WHITE CEASERSTONE COUNTERTOP 6MM OSPREY CEASERSTONE COUNTERTOP WITH ROUNDED PENCIL EDGES CEASERSTONE COUNTERTOP MUST BE FIXED TO A LEVEL SURFACE AND GLUED TO THE KITCHEN BASE CABINETS AND PROTECTED DURING THROUGHOUT THE CONSTRUCTION.. SERVICES MUST BE IN PLACE BEFORE INSTALLATION. ENSURE FRAMING IS PLUMB, LEVEL &SQUARE AND THAT THE AREA IS WEATHER PROOF. ENSURE THAT STUD SPACING TAKES INTO ACCOUNT THE WIDTH OF PLASTERBOARD SHEETS AND ALLOWS FIXING POINTS AT ITS EDGES. STANDARD CORE 13MM PLASTERBOARD TO BE FIXED ALONG WALLS STUDS AND 15MM FROM SHEET EDGES AND ENDS WITH 30MM 'W' TYPE PLASTERBOARD SCREWS. ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS. OV KITCHENAID 30" SINGLE ELECTRIC WALL OVEN PTY PANTRY SB SPLASHBACK DW DISHWASER TO BE SELECTED BY CLIENT RH 24" ISLAND ROUND CHIMNEY RANGEHOOD KA-123-CS. ST KITCHENAID 40" GAS COOKTOP REF JENN-AIR 25.02 SIDE-BY-SIDE REFRIDGERATOR SK SCHOCK STONE DOUBLE BOWL KITCHEN SINK LEGEND GENERAL NOTES PRODUCED BY AN AUTODESK STUDENT PRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT
  • 15.
    10001440 749 450 1571600 1899 1093 13MM PLASTERBOARD 100X300 MANHATTAN TILE MR VN SH BT TL 172X600MM INSUDTRIE MOSAIC SATIN TILE 1045 90 765 283 VN BT SH 2 13MM PLASTERBOARD 100X300 MANHATTAN TILE 172X600MM INSUDTRIE MOSAIC SATIN TILE SHOWER PANEL 1525901050 3822 8931007 1381 1600 1899 1 W15 1125 1057 2 W15 SK VN SH 2 250X250 ECO TILES 5 W15 1606 691 933 11009020015201801000 900 2330 SH SK VN BT TL 250X250 ECO TILES 1100 90160 1600 160 980 2400519 1000 MR VN TL SH 100X300 MANHATTAN TILE SHOWER PANEL 172X600 INDUSTRIE MOSAIC TILE PB 7 W15 8 W15 2180 1461 670 273 915 273 1421 2060 1412 1449 2000 2820 SK DR WM BASE CABINETS 250X250 ECO TILES 7801821 1000 1000 180 1000 1000 288 2412 180 0811 11 16 250X250 ECO TILES PB PB 3450 90 1315 80790200 1000 1000 DRWM PB PARTITION WALL 250X250 ECO TILES 16 1420 Scale Checked by Drawn by Date Project number As indicated Internal Elevations II P1.0 FINCH STREET NEW DWELLING MR A AND MRS M METCALF Issue Date Author HALEN MOKA 24 FINCH STREET, BEECHWORTH VIC W15 1 : 50 Section 9 1 1 : 50 Section 10 2 1 : 50 Internal Plan Bathroom 3 1 : 50 Internal Plan Ensuite 4 1 : 50 Section 13 5 1 : 50 Internal Plan Laundry 6 1 : 50 Section 11 7 1 : 50 Section 12 8 BATH LUNA STONE BATH 1680 W. LUNA WHITE HEADREST BASIN VISTA SAVANNA SEMI-RECESSED BASIN MIRROR FORME MIRROR MLD 1200 SHOWER HEAD SENNA STAINLESS STEEL WALL FIXED SHOWER HEAD BATHROOM SINK RUSH STAINLESS STEEL WALL BASIN 3 PEICE OUTLET SET TAPS BATH SPOUT RUSH WALL MOUNTED STAINLESS STEEL BATH SPOUT 3 PEICE SET TILES: ECO ALABLASTER GRIGIO LAPPATO BEAUMON TILES (FLOOR) MANHATTAN TAUPE MATTE DECOR 100X300 TILES (WALL) INDUSTRIE MOSAIC SATIN 172X600MM SHEET (STONE FEATURE) BATHROOM GATEWAY 1200 WALL HUNG VANITY WITH CEASERSTONE TOP VANITY TOILET LUCCA LOSE COUPLED TOILET SUITE SHOWER BASE 1050X1520MM LUNA SHOWER BASE W/ REAR WASTE DRAIN BATHROOM LAUNDRY ENSUITE BASIN CLARK 45L FLUSHLINE STANDARD SINGLE STAINLESS STEEL LAUNDRY BASIN. SINK TAPS MONDELLA WELS 4 STAR 7L/MIN SIDE LEVER CURVED STAINLESS STEEL BASIN MIXER. TILES: ECO ALABLASTER GRIGIO LAPPATO BEAUMON TILES LAUNDRY BEFORD 1000MM WHITE 2 DOOR BASE CABINET CUPBOARDS W/CEASER STONE TOP AND KABOODLE URBAN OAK MODERN VENEER FINISH X4 BEFORD 1000MM WHITE 2 DOOR WALL UNIT W/ KABOODLE URBAN OAK MODERN VENEER FINISH X2 W/SILVER ANODISED ALUMINIUM 'G' STYLE GRIP HANDLES. 19MM MOISTURE RESISTANT NATURAL WHITE MELAMINE PARTICLE BOARD WITH HIGH GLOSS FINISH. ENSURE CABINETRY IS FIXED AND LEVELED. ALL WALL HUNG CABINETS MUST BE FIXED USING THE PROVIDED WALL ANCHORS AND SCREWS TO THE WALL STUDS. WASHING MACHINE: TO BE SELECTED BY CLIENT DRYER: TO BE SELECTED BY CLIENT BATH LUNA STONE BATH 1680 W. LUNA WHITE HEADREST BASIN VISTA SAVANNA SEMI-RECESSED BASIN MIRROR FORME MIRROR MLD 1200 SHOWER HEAD SENNA STAINLESS STEEL WALL FIXED SHOWER HEAD BASIN TAPS RUSH STAINLESS STEEL WALL BASIN 3 PEICE OUTLET SET BATH SPOUT VIVID FLOOR MOUNTED STAINLESS STEEL BATH SPOUT W/RUSH STAINLESS STEEL WALL MOUNTED TAPS. TILES: ECO ALABLASTER GRIGIO LAPPATO BEAUMON TILES (FLOOR) MANHATTAN TAUPE MATTE DECOR 100X300 TILES (WALL) INDUSTRIE MOSAIC SATIN 172X600MM SHEET (STONE FEATURE) BATHROOM GATEWAY 1200 WALL HUNG VANITY WITH CEASERSTONE TOP VANITY W/SILVER ANODISED ALUMINIUM 'G' STYLE GRIP HANDLES. 19MM MOISTURE RESISTANT NATURAL WHITE MELAMINE PARTICLE BOARD WITH HIGH GLOSS FINISH. ENSURE CABINETRY IS FIXED AND LEVELED TO PREVENT DOORS FROM SWINGING OPEN UNINTENTIONALLY AND TO CREATE AN EVEN FIX WITH THE COUNTERTOP. TOILET LUCCA LOSE COUPLED TOILET SUITE SHOWER BASE 1000X1600MM LUNA SHOWER BASE W/ REAR WASTE DRAIN BUILDER TO INSTALL TO MANUFACTURERES SPECS. GENERAL NOTES ALL CUPBOARDS AND VANITIES ARE TO BE ASSEMBLED AND INSTALLED INACCORDANCE WITH THE MANUFACTURERS SPECIFICATIONS. ALL TAPWARE, SHOWERHEADS, TOILETS AND BASINS TO BE INSTALLED BY CERTIFIED PLUMBER. GLASS SHOWER PANELS ARE TO BE INSTALLED TO MANUFACTURERS SPECIFICATIONS AFTER SHOWER BASE HAS BEEN INSTALLED, WATER-PROOFED AND TESTED FOR LEAKAGE. SHOWER BASE TO BE INSTALLED TO MANUFACTUERES SPECIFICATIONS. ALL TILEED AREAD MUST BE WATERPROOFED AND BE FIXED BY A PROFESSIONAL TILER. SEE W13 FOR WATERPROOFING OF WET AREAS DETAIL. SERVICES MUST BE IN PLACE BEFORE INSTALLATION. ENSURE FRAMING IS PLUMB, LEVEL &SQUARE AND THAT THE AREA IS WEATHER PROOF. ENSURE THAT STUD SPACING TAKES INTO ACCOUNT THE WIDTH OF PLASTERBOARD SHEETS AND ALLOWS FIXING POINTS AT ITS EDGES. STANDARD CORE 13MM PLASTERBOARD TO BE FIXED ALONG WALLS STUDS AND 15MM FROM SHEET EDGES AND ENDS WITH 30MM 'W' TYPE PLASTERBOARD SCREWS. CEILING MUST HAVE PEER 16X6000MM 0.38BMT DOMESTIC CEILING BATTEN FCDB-60 @450 CNTRS INSTALLED TO MANUFACTURERES SPECS PRIOR TO FIXING PLASTERBOARD. ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH AS2589- GYPSUM LININGS. PB 13MM STANDARD CORE PLASTERBOARD WM WASHING MACHINE DR DRYER MR MIRROR VN VANITY TL TOILET BT BATH LEGEND PRODUCED BY AN AUTODESK STUDENT PRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT
  • 16.
    9MM TOUGHENED SAFETYGLASS 13X90 TURPENTINE DECKING FIXED W/ 50MM SELF DRTILLING DECKING SCREWS PREMIUM FLANGED ROUND SPIGOT. 150MM CNC-MACHINED FROM 316 MARINE GRADE STAINLESS STEEL BILLET, W/6MM SOLID PLATEPRESS FITTED AND WELDED. FIXED TO MANUFS SPECIFICATIONS. 90MM GAL STEEL STIRRUP 2X90X45 MGP10 TIMBER DECKING JOISTS DOOR CERAMIC TILES CARPET FLOORING IN-SITU PERIMETER FLASHING BRASS OR ALUMINIUM ANGLE 90MM STUD WALL CERAMIC WALL TILES VILLABOARD LINING INTERNAL IN-SITU FLASHING FLEXIBLE WET AREA SEALANT FLOOR TILES MORTAR BED FLOORING SUITABLE TAPE FLOOR JOIST GALVANISED STIRUP IN 20MPA CONRETE 60MM STUMP SLIDING DOOR TIMBER DECKING 90X13 TURPENTINE FIXED WITH 50MM GALV. SELF DRILLING DECKING SCREWS W/10MM GAP BETWEEN DECKING AND BUILDING TO ALLOW FOR MOVEMENT. CONSTRUCTION AND FIXING TO COMPLY WITH BAL 12.5. 2X90X45 F8 SEASONED TURPENTINE FIXED WITH M12 GALV. BOLT-NUT-WASHER. W/45X90MM RECESS FOR BEARER. BEAER 2/90X45 TURPENTINE 100MM 20MPA CONCRETE SLAB 3-L11TM MESH REINFORCEMENT FLOORBOARDS MIN150 10MM BLUE BOARD SHEETING. TOP FIXED WITH 50MM BATTEN SCREWS AND HELD BEHIND TURPENTINE EDGE DECKING. THE OTHER END MUST BE PARTIALLY EMBEDDED INTO THE GROUND A MINIMUM OF 150MM. MIN150 ENSURE THAT STUD SPACING TAKES INTO ACCOUNT THE WIDTH OF PLASTERBOARD SHEETS AND ALLOWS FIXING POINTS AT ITS EDGES. STANDARD CORE 13MM PLASTERBOARD TO BE FIXED ALONG WALLS STUDS AND 15MM FROM SHEET EDGES AND ENDS WITH 30MM 'W' TYPE PLASTERBOARD SCREWS. ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS. R2.7 HIGH PERFORMANCE GOLD BRADFORD INSULATION BATTS 1160X580 CUT TO FIT SECURED WITH 13MM STANDARD CORE PLASTERBOARD. 90X45 MGP10 BOTTOM PLATE FIXED WITH BOLT DYNABOLT 12X100MM HEX NUT EA 2X90X45 MGP10 TOP PLATE FIXED TO TIMBER STUD WALL WITH 100X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS COLORBOND® STEEL CONFORMING TO AS 1397-G550- AM100 AND AS 2728. COLOUR: MONUMENT 0.42 BMT FASTENERS SHOULD BE SELECTED TO MATCH THE GRADE OF THE ROOFING MATERIAL. SIZE: AS PER ROOF SIZE. SPACING: 1200MM THE ROOF SHEETING AND ACCESSORIES SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. 90MM COLOURBOND LYSAGHT QUAD GUTTER 'MONUMENT' FIXED TO MANUFACTURERES SPECS DN 90 TYPE C METAL DOWNPIPE 'MONUMENT' LOW GLOSS FINISH 220mm X 140mm METAL RAINWATER HEAD FIXED TO CLADDING USING MANUFACTURERS SPEC 200X38MM TURPENTINE FASCIA BOARD FIXED 100X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS CEILING MUST HAVE PEER 16X6000MM 0.38BMT DOMESTIC CEILING BATTEN FCDB-60 @450 CNTRS INSTALLED TO MANUFACTURERES SPECS PRIOR TO FIXING PLASTERBOARD. ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS. 100X25 TURPENTINE CLADDING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL CLOUTS END GRAIN TO BE SEALED AND INTERGRAIN REDWOOD STAIN TO BE APPLIED TO CLADDING AS PER MANUFACTURERES SPECS. WALL MUST BE SARKED WITH AMETALIN SILVERWRAP FOIL INSULATION AND EXTERNALLY FIXED WITH 6MM CEMENT SHEETING USING 30MM GAL CLOUTS. 50X50 HORIZONTAL BATTENS TO BE FIXED TO VERTICAL BATTENS AT 600 CNTRS WITH 65MM BATTEN SCREWS. 600 0.2MM POLYETHELYNE VAPOUR BARRIER 400X300 EXTERNAL EDGE BEAMS TO CONTAIN 3-L11TM REINFORCEMENTMESH 30MM FROM BOTTOM OF BEAM. 72 90X45 MGP10 NOGGIN TWO NOGGINS ARE TO BE PLACED BETWEEN EACH TIMBER STUD. ONE @900MM AND ONE @1800MM UP THE HEIGHT OF THE WALL. FIXED TO TIMBER STUD WALL WITH 100X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS 200X125MM STEEL RHS INSTALLED AND FIXED TO ENGINEERS SPECIFICATIONS. COLORBOND® STEEL CONFORMING TO AS 1397-G550-AM100 AND AS 2728. COLOUR: MONUMENT 0.42 BMT FASTENERS SHOULD BE SELECTED TO MATCH THE GRADE OF THE ROOFING MATERIAL. SIZE: AS PER ROOF SIZE. SPACING: 1200MM THE ROOF SHEETING AND ACCESSORIES SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. CEILING MUST HAVE PEER 16X6000MM 0.38BMT DOMESTIC CEILING BATTEN FCDB-60 @450 CNTRS INSTALLED TO MANUFACTURERES SPECS PRIOR TO FIXING PLASTERBOARD. ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS. R2.7 HIGH PERFORMANCE GOLD BRADFORD INSULATION BATTS 1160X580 CUT TO FIT SECURED WITH 13MM STANDARD CORE PLASTERBOARD.ENSURE THAT STUD SPACING TAKES INTO ACCOUNT THE WIDTH OF PLASTERBOARD SHEETS AND ALLOWS FIXING POINTS AT ITS EDGES. STANDARD CORE 13MM PLASTERBOARD TO BE FIXED ALONG WALLS STUDS AND 15MM FROM SHEET EDGES AND ENDS WITH 30MM 'W' TYPE PLASTERBOARD SCREWS. ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS. 180X90 MGP10 RAFTER 100X250 GAL NAIL PLATE 152.00° 7.00° 90.00° 55.00° 13MM STANDARD CORE PLASTERBOARD BULKHEAD 125.00° 83.00° 260 151 151 180X45 MGP10 RAFTER FIXED WITH 100X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS CEILING MUST HAVE PEER 16X6000MM 0.38BMT DOMESTIC CEILING BATTEN FCDB-60 @450 CNTRS INSTALLED TO MANUFACTURERES SPECS PRIOR TO FIXING PLASTERBOARD. ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS. VELUX DECK SEAL COLORBOND® STEEL CONFORMING TO AS 1397-G550- AM100 AND AS 2728. COLOUR: MONUMENT 0.42 BMT FASTENERS SHOULD BE SELECTED TO MATCH THE GRADE OF THE ROOFING MATERIAL. SIZE: AS PER ROOF SIZE. SPACING: 1200MM THE ROOF SHEETING AND ACCESSORIES SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. 30-60 35X90 MGP10 ROOF BATTEN OUTSIDE FRAME WIDTH VELUX MIDDLE GUTTER WITH VELUX FLASHING VELUX VS/E VELUX VS/E R2.7 HIGH PERFORMANCE GOLD BRADFORD INSULATION BATTS 1160X580 CUT TO FIT SECURED WITH 13MM STANDARD CORE PLASTERBOARD. VELUX EKW FLASHING GUTTER THERMOSEAL SARKING 180X45 MGP10 RAFTER FIXED WITH 100X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS CEILING MUST HAVE PEER 16X6000MM 0.38BMT DOMESTIC CEILING BATTEN FCDB-60 @450 CNTRS INSTALLED TO MANUFACTURERES SPECS PRIOR TO FIXING PLASTERBOARD. ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH AS2589- GYPSUM LININGS. VELUX DECK SEAL COLORBOND® STEEL CONFORMING TO AS 1397-G550-AM100 AND AS 2728. COLOUR: MONUMENT 0.42 BMT FASTENERS SHOULD BE SELECTED TO MATCH THE GRADE OF THE ROOFING MATERIAL. SIZE: AS PER ROOF SIZE. SPACING: 1200MM THE ROOF SHEETING AND ACCESSORIES SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. 35X90 MGP10 ROOF BATTEN VELUX VS/E R2.7 HIGH PERFORMANCE GOLD BRADFORD INSULATION BATTS 1160X580 CUT TO FIT SECURED WITH 13MM STANDARD CORE PLASTERBOARD. THERMOSEAL WATERPROOF SARKING 100 M IN Scale Checked by Drawn by Date Project number As indicated Details P1.0 FINCH STREET NEW DWELLING MR A AND MRS M METCALF Issue Date Author HALEN MOKA 24 FINCH STREET, BEECHWORTH VIC W16 1 : 5 Balustrade detail 1 1 : 10 Typical Wet Areas 4 1 : 10 Decking Construction 31 : 10 Brick Veneer Section Detail 2 1 : 10 Roof Pitch Change 6 1 : 10 Horizontal Skylight Section 7 1 : 10 Vertical Skylight section 8 PRODUCED BY AN AUTODESK STUDENT PRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT
  • 17.
    ENSURE THAT STUDSPACING TAKES INTO ACCOUNT THE WIDTH OF PLASTERBOARD SHEETS AND ALLOWS FIXING POINTS AT ITS EDGES. STANDARD CORE 13MM PLASTERBOARD TO BE FIXED ALONG WALLS STUDS AND 15MM FROM SHEET EDGES AND ENDS WITH 30MM 'W' TYPE PLASTERBOARD SCREWS. ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS. R2.7 HIGH PERFORMANCE GOLD BRADFORD INSULATION BATTS 1160X580 CUT TO FIT SECURED WITH 13MM STANDARD CORE PLASTERBOARD. 90X45 MGP10 BOTTOM PLATE FIXED WITH BOLT DYNABOLT 12X100MM HEX NUT EA 2X90X45 MGP10 TOP PLATE FIXED TO TIMBER STUD WALL WITH 100X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS COLORBOND® STEEL CONFORMING TO AS 1397- G550-AM100 AND AS 2728. COLOUR: MONUMENT 0.42 BMT FASTENERS SHOULD BE SELECTED TO MATCH THE GRADE OF THE ROOFING MATERIAL. SIZE: AS PER ROOF SIZE. SPACING: 1200MM THE ROOF SHEETING AND ACCESSORIES SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. 90MM COLOURBOND LYSAGHT QUAD GUTTER 'MONUMENT' FIXED TO MANUFACTURERES SPECS DN 90 TYPE C METAL DOWNPIPE 'MONUMENT' LOW GLOSS FINISH 220mm X 140mm METAL RAINWATER HEAD FIXED TO CLADDING USING MANUFACTURERS SPEC 200X38MM TURPENTINE FASCIA BOARD FIXED 100X2.8MM BRIGHT 'D' HEAD MACHINE DRIVEN NAILS CEILING MUST HAVE PEER 16X6000MM 0.38BMT DOMESTIC CEILING BATTEN FCDB-60 @450 CNTRS INSTALLED TO MANUFACTURERES SPECS PRIOR TO FIXING PLASTERBOARD. ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS. 100X25 TURPENTINE CLADDING INTERGRAIN REDWOOD 'NATURAL' STAIN FIXED WITH 50MM GAL CLOUTS END GRAIN TO BE SEALED AND INTERGRAIN REDWOOD STAIN TO BE APPLIED TO CLADDING AS PER MANUFACTURERES SPECS. WALL MUST BE SARKED WITH AMETALIN SILVERWRAP FOIL INSULATION AND EXTERNALLY FIXED WITH 6MM CEMENT SHEETING USING 30MM GAL CLOUTS. 50X50 HORIZONTAL BATTENS TO BE FIXED TO VERTICAL BATTENS AT 600 CNTRS WITH 65MM BATTEN SCREWS. 200 12 15 600 0.2MM POLYETHELYNE VAPOUR BARRIER 400X300 EXTERNAL EDGE BEAMS TO CONTAIN 3- L11TM REINFORCEMENTMESH 30MM FROM BOTTOM OF BEAM. 0.2MM POLYETHELYNE VAPOUR BARRIER SL82 SLAB REINFORCEMENT MESH 150MM 25MPA CONCRETE SLAB 250MM BRICK VENEER WALL 90X45 MGP10 BOTTOM PLATE FIXED WITH BOLT DYNABOLT 12X100MM HEX NUT EA 250 ENSURE THAT STUD SPACING TAKES INTO ACCOUNT THE WIDTH OF PLASTERBOARD SHEETS AND ALLOWS FIXING POINTS AT ITS EDGES. STANDARD CORE 13MM PLASTERBOARD TO BE FIXED ALONG WALLS STUDS AND 15MM FROM SHEET EDGES AND ENDS WITH 30MM 'W' TYPE PLASTERBOARD SCREWS. ALL PLASTERBOARD AND ITS RESPECTIVE INSALLATION MUST COMPLY WITH AS2589-GYPSUM LININGS. 300X300 INTERNAL BEAMS TO CONTAIN 3-L11TM REINFORCMENT STEEL 30MM FROM BOTTOM OF BEAM AND @ 6M MAX CTRS. GARAGE SLAB FFL 8864 SAND FILTERWRAP GEOFABRIC FREE DRAINING GRANULAR FILL AGGREGATION PIPE TO BE VINIDEX 100MM X 20M SLOTTED DRAINCOIL AND INSTALLED BELOW AND BEHIND THE RETAINING WALL ABOVE GEO FABRIC AND COVERED IN CORSE GRANULAR FILL. GEO FABRIC MUST BE USED TO SEPERATE THE GRANULAR FILL AND SOIL BEHIND THE RETAINING WALL. 4X110X220 TREATED PINE SLEEPERS FIXED AT THE TOP AT EACH END OF EACH SLEEPER WITH A 65MM BATTEN SCREW. A HOLE MUST BE DRILLED THROUGH THE STEEL COLUMN FIRST. 120MM GALVANISED STEEL 'I' BEAM CHANNEL EARTH 300X300 20MPA CONCRETE FOOTING 20X150 MGP10 TOP TIMBER COVER TO BE FIXED WITH 65MM BATTEN SCREW 0.2 POLYETHYLENE VAPOUR BARRIER MUST BE USED TO DIRECT WATER BUILDUP TO THE AGGREGATION PIPE AND PREVENT WATER FROM TRANSFERRING THROUGH THE WALL EARTH Scale Checked by Drawn by Date Project number As indicated Details II P1.0 FINCH STREET NEW DWELLING MR A AND MRS M METCALF Issue Date Author HALEN MOKA 24 FINCH STREET, BEECHWORTH VIC W17 1 : 10 Timber wall Section 2 1 : 10 Slab Step down detail 3 1 : 10 Retaining wall 4 PRODUCED BY AN AUTODESK STUDENT PRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT PRODUCEDBYANAUTODESKSTUDENTPRODUCT