This document provides information on the various components needed for a modular operating theatre (OT). It describes flooring, control panels, overflow ports, laminar air flow systems, sliding doors, surgical pendants, anesthetic pendants, wall panels, ceilings, x-ray view screens, writing boards, cleanroom luminaires, LED operating theatre lights, and integrated HD cameras. The components are designed to ensure sterility, easy maintenance and effective utilization of the OT in accordance with applicable standards and certificates.
Isoclean Healthcare Platform Isolator (HPI G3)Esco Group
The Isoclean® Healthcare Platform Isolator (HPI-G3) facilitates the isolation of a product or process while providing the required sterile/aseptic environment. It is configured to operate at positive or negative pressure in single or recirculating airflow. This equipment provides a comprehensive range of personnel and product protection in addition to the surrounding work areas and the environment.
• Pharmacy Compounding (Chemotherapy/TPN)
• Small-scale Potent Material Handling
• Aseptic Processing
• Research and Development
• Cell processing
Vibration test assembly with Environmental Test Chamber is designed and manufactured as per specific requirement of the customers meeting various international standards.
Isoclean Healthcare Platform Isolator (HPI G3)Esco Group
The Isoclean® Healthcare Platform Isolator (HPI-G3) facilitates the isolation of a product or process while providing the required sterile/aseptic environment. It is configured to operate at positive or negative pressure in single or recirculating airflow. This equipment provides a comprehensive range of personnel and product protection in addition to the surrounding work areas and the environment.
• Pharmacy Compounding (Chemotherapy/TPN)
• Small-scale Potent Material Handling
• Aseptic Processing
• Research and Development
• Cell processing
Vibration test assembly with Environmental Test Chamber is designed and manufactured as per specific requirement of the customers meeting various international standards.
The Esco Cytoculture Cytotoxic Safety Cabinet is the premium solution for cytotoxic/antineoplastic drug processing, providing the highest level of patient, pharmacist and environmental protection. This revolutionary product builds on Esco’s experience of more than 20 years as a global leader in biological safety containment technology.
The unique demands of handling and preparing cytotoxic drugs for use in chemotherapy require a specialized cabinet. As cytotoxic drugs cannot be inactivated by chemical decontamination, Class II biosafety cabinets should not be used. With this in mind, Esco has developed a highly specialized range of cabinets designed especially for handling these potentially dangerous drugs.
Key Benefits:
-Safe filter changing
-Safer dual exhaust filters
-HPA certified to EN 12469
Esco Pharma Laminar Flow Straddle Units, Single and DoubleEsco Group
Esco Enterprise Laminar Flow Straddle Units are designed for larger-scale process protection in industrial applications typically requiring multiple units connected in an assembly line configuration. They may be placed within an ISO Class 8 cleanroom to provide an ultra-clean environment directly at the process level, without the initial and operating costs associated with a full-sized ISO Class 3 or 4 cleanroom.
The OKO-22M-UT ultrasonic flaw detector is a standalone electronic unit and is intended for application in high-performance automated multi-channel NDT Systems, mechanized NDT systems in NDT laboratories and for manual testing.
Magnetrol is a globally recognized manufacturer of level and flow measurement instrumentation and devices. Technologies include inferential and direct measurement.
Weiber Stability Test Chambers/ are widely used for
confirmatory studies for direct comparison of drug
substance under controlled environmental conditions.
Weiber Stability Test Chambers/ are widely used for
confirmatory studies for direct comparison of drug
substance under controlled environmental conditions.
Esco Evidence Drying Cabinet is a negative pressure cabinet designed to provide security, tamper proof, and prevent loss of integrity and credibility and possible cross-contamination of evidence and impede any harmful airborne pathogens, putrid odors, and other gases from escape that may harm or infect employees/technicians.
We are manufacturers of horizontal autoclave, triple walled horizontal autoclave India since 1990. Our horizontal autoclaves are widely used for day to day mass scale sterilization procedures and in various bulk laboratory applications . For more information please log on http://cutt.us/SZ7Mr
We are one of the fastest growing Manufacturer, service provider and Supplier firms providing added value in its offered superior quality HVAC & Clean Room Solutions. Apart from the industry proven design of our products.
Series One Safety Transmitter, Pressure and Temperature SwitchIves Equipment
The One Series Safety Transmitter is a transmitter-switch for monitoring pressure or temperature and meets the requirements of SIL 2 for random integrity at HFT = 0, SIL 3 for random integrity at HFT = 1 and SIL 3 for systematic capability. The One Series Safety Transmitter incorporates UE’s patented IAW self diagnostics, redundant and diverse signal processing and software algorithms to detect abnormalities in the process and internal faults. The design is based on a powerful microprocessor that provides an extremely fast response time for emergency shutdown situations.
The One Series Safety Transmitter was designed with features that simplify installation, improve productivity, and eliminate nuisance trips. “I Am Working” sensor diagnostics with redundant data processing detect open, shorted, and plugged sensing elements. The transmitter’s analog output conforms to the NAMUR NE 43 standard and provides process variable (PV) and detected-fault information. Discrete outputs provide a fail-safe (open) emergency shutdown when a fault is detected. Set point and deadband (reset point) are 100% programmable. The instrument is password protected to prevent unwanted parameter changes; eliminating the risk of tampering. In addition, LED backlighting enhances viewing of process variables, parameters, and status in dimly lit areas.
The Esco Cytoculture Cytotoxic Safety Cabinet is the premium solution for cytotoxic/antineoplastic drug processing, providing the highest level of patient, pharmacist and environmental protection. This revolutionary product builds on Esco’s experience of more than 20 years as a global leader in biological safety containment technology.
The unique demands of handling and preparing cytotoxic drugs for use in chemotherapy require a specialized cabinet. As cytotoxic drugs cannot be inactivated by chemical decontamination, Class II biosafety cabinets should not be used. With this in mind, Esco has developed a highly specialized range of cabinets designed especially for handling these potentially dangerous drugs.
Key Benefits:
-Safe filter changing
-Safer dual exhaust filters
-HPA certified to EN 12469
Esco Pharma Laminar Flow Straddle Units, Single and DoubleEsco Group
Esco Enterprise Laminar Flow Straddle Units are designed for larger-scale process protection in industrial applications typically requiring multiple units connected in an assembly line configuration. They may be placed within an ISO Class 8 cleanroom to provide an ultra-clean environment directly at the process level, without the initial and operating costs associated with a full-sized ISO Class 3 or 4 cleanroom.
The OKO-22M-UT ultrasonic flaw detector is a standalone electronic unit and is intended for application in high-performance automated multi-channel NDT Systems, mechanized NDT systems in NDT laboratories and for manual testing.
Magnetrol is a globally recognized manufacturer of level and flow measurement instrumentation and devices. Technologies include inferential and direct measurement.
Weiber Stability Test Chambers/ are widely used for
confirmatory studies for direct comparison of drug
substance under controlled environmental conditions.
Weiber Stability Test Chambers/ are widely used for
confirmatory studies for direct comparison of drug
substance under controlled environmental conditions.
Esco Evidence Drying Cabinet is a negative pressure cabinet designed to provide security, tamper proof, and prevent loss of integrity and credibility and possible cross-contamination of evidence and impede any harmful airborne pathogens, putrid odors, and other gases from escape that may harm or infect employees/technicians.
We are manufacturers of horizontal autoclave, triple walled horizontal autoclave India since 1990. Our horizontal autoclaves are widely used for day to day mass scale sterilization procedures and in various bulk laboratory applications . For more information please log on http://cutt.us/SZ7Mr
We are one of the fastest growing Manufacturer, service provider and Supplier firms providing added value in its offered superior quality HVAC & Clean Room Solutions. Apart from the industry proven design of our products.
Series One Safety Transmitter, Pressure and Temperature SwitchIves Equipment
The One Series Safety Transmitter is a transmitter-switch for monitoring pressure or temperature and meets the requirements of SIL 2 for random integrity at HFT = 0, SIL 3 for random integrity at HFT = 1 and SIL 3 for systematic capability. The One Series Safety Transmitter incorporates UE’s patented IAW self diagnostics, redundant and diverse signal processing and software algorithms to detect abnormalities in the process and internal faults. The design is based on a powerful microprocessor that provides an extremely fast response time for emergency shutdown situations.
The One Series Safety Transmitter was designed with features that simplify installation, improve productivity, and eliminate nuisance trips. “I Am Working” sensor diagnostics with redundant data processing detect open, shorted, and plugged sensing elements. The transmitter’s analog output conforms to the NAMUR NE 43 standard and provides process variable (PV) and detected-fault information. Discrete outputs provide a fail-safe (open) emergency shutdown when a fault is detected. Set point and deadband (reset point) are 100% programmable. The instrument is password protected to prevent unwanted parameter changes; eliminating the risk of tampering. In addition, LED backlighting enhances viewing of process variables, parameters, and status in dimly lit areas.
Introduction to AI for Nonprofits with Tapp NetworkTechSoup
Dive into the world of AI! Experts Jon Hill and Tareq Monaur will guide you through AI's role in enhancing nonprofit websites and basic marketing strategies, making it easy to understand and apply.
A Strategic Approach: GenAI in EducationPeter Windle
Artificial Intelligence (AI) technologies such as Generative AI, Image Generators and Large Language Models have had a dramatic impact on teaching, learning and assessment over the past 18 months. The most immediate threat AI posed was to Academic Integrity with Higher Education Institutes (HEIs) focusing their efforts on combating the use of GenAI in assessment. Guidelines were developed for staff and students, policies put in place too. Innovative educators have forged paths in the use of Generative AI for teaching, learning and assessments leading to pockets of transformation springing up across HEIs, often with little or no top-down guidance, support or direction.
This Gasta posits a strategic approach to integrating AI into HEIs to prepare staff, students and the curriculum for an evolving world and workplace. We will highlight the advantages of working with these technologies beyond the realm of teaching, learning and assessment by considering prompt engineering skills, industry impact, curriculum changes, and the need for staff upskilling. In contrast, not engaging strategically with Generative AI poses risks, including falling behind peers, missed opportunities and failing to ensure our graduates remain employable. The rapid evolution of AI technologies necessitates a proactive and strategic approach if we are to remain relevant.
Read| The latest issue of The Challenger is here! We are thrilled to announce that our school paper has qualified for the NATIONAL SCHOOLS PRESS CONFERENCE (NSPC) 2024. Thank you for your unwavering support and trust. Dive into the stories that made us stand out!
Unit 8 - Information and Communication Technology (Paper I).pdfThiyagu K
This slides describes the basic concepts of ICT, basics of Email, Emerging Technology and Digital Initiatives in Education. This presentations aligns with the UGC Paper I syllabus.
Normal Labour/ Stages of Labour/ Mechanism of LabourWasim Ak
Normal labor is also termed spontaneous labor, defined as the natural physiological process through which the fetus, placenta, and membranes are expelled from the uterus through the birth canal at term (37 to 42 weeks
2024.06.01 Introducing a competency framework for languag learning materials ...Sandy Millin
http://sandymillin.wordpress.com/iateflwebinar2024
Published classroom materials form the basis of syllabuses, drive teacher professional development, and have a potentially huge influence on learners, teachers and education systems. All teachers also create their own materials, whether a few sentences on a blackboard, a highly-structured fully-realised online course, or anything in between. Despite this, the knowledge and skills needed to create effective language learning materials are rarely part of teacher training, and are mostly learnt by trial and error.
Knowledge and skills frameworks, generally called competency frameworks, for ELT teachers, trainers and managers have existed for a few years now. However, until I created one for my MA dissertation, there wasn’t one drawing together what we need to know and do to be able to effectively produce language learning materials.
This webinar will introduce you to my framework, highlighting the key competencies I identified from my research. It will also show how anybody involved in language teaching (any language, not just English!), teacher training, managing schools or developing language learning materials can benefit from using the framework.
Macroeconomics- Movie Location
This will be used as part of your Personal Professional Portfolio once graded.
Objective:
Prepare a presentation or a paper using research, basic comparative analysis, data organization and application of economic information. You will make an informed assessment of an economic climate outside of the United States to accomplish an entertainment industry objective.
Operation “Blue Star” is the only event in the history of Independent India where the state went into war with its own people. Even after about 40 years it is not clear if it was culmination of states anger over people of the region, a political game of power or start of dictatorial chapter in the democratic setup.
The people of Punjab felt alienated from main stream due to denial of their just demands during a long democratic struggle since independence. As it happen all over the word, it led to militant struggle with great loss of lives of military, police and civilian personnel. Killing of Indira Gandhi and massacre of innocent Sikhs in Delhi and other India cities was also associated with this movement.
1. MODULAR OT
Operation theatre is that specialized facility of the hospital where life
saving or life improving procedures are carried out on the human body
by invasive methods under strict aseptic conditions in a controlled
environment by specially trained personnel to promote healing and
cure with maximum safety, comfort and economy. It is imperative that
operation theatre (OT) is designed scientifically to ensure sterility, easy
maintenance and effective utilization. A civil – mechanical –electrical –
electronic – biomedical combination driven and co-ordinated by needs
, preferences and safety of the medical surgical team forms the basis
of planning , starting and maintaining an operation theatre.
2.
3. • VARIOUS COMPONENTS OF MODULAR AND SEMI MODULAR OT
• Antistatic Flooring - ESD vinyl
The flooring confirm to following standards
• EN 1081/IEC 613404, EN 1815 & EN 12466.Solid vinyl tile (SVT)(2mm).
• 2.00mm, total weight 3.0 g/m2 polyurethane reinforced ,scratch resistant, fire
resistant, chemical resistant , slip resistant, anti-fungi & bacterial growth ,
dimensional stability ≤0.40%, static electrical charger < 2Kv , impact sound
reduction approx. +4bd, electrical resistant.
4. Operation theatre control panel , surgeon control panel
All the controls within the theatre should be located on a control panel mounted recessed in the
theatre wall. The panel will incorporate all the necessary controls for the correct operation and
monitoring of equipment and services within the operating theatre. Each control panel shall contain:
• Display & control for Temp & humidity.
• Control of Venetian blinds in windows & doors.
• Status Indication of up to 5 Medical Gases + 1 Vacuum.
• On/Off and regulation of Intensity of illumination in OT.
• Digital Display of Real Time / Elapsed time
• Intercom with speaker & microphone.
• Microprocessor controlled Liquid Crystal Text Backlit display with 4 lines of 20 characters each.
• There should be five illuminated buttons for Test, acknowledge, scroll, text & Menu.
• Audio-visual alarms.
• Normal, Warning & Alarm LED indications.
Certificate of country of origin and manufacturers test certificates to be submitted after
installation
5. Over Flow Port
Provided in theatre to prevent cross contamination of air from clean
and dirty areas.
Over flow port will be strategically placed, enable differential room
pressure to be maintained and ensure that when doors are opened
between clean and dirty area.
Over flow port, made of Stainless Steel 1.4301 (SS 304 grade)
Have filter element, which should be openable & cleanable.
Volume to be exhausted be between 175m3/h to 200m3/h.
Certificate of country of origin and manufacturers test certificates to
be submitted after installation
6. Laminar air flow
One of the main objectives of any operating theatre system is
to dilute the bacteria generated by the operating team and
patient in the theatre and to create an Air flow pattern that
carries contaminated air away from the operating table &
entering surgical wounds. A Laminar Flow System should
contain three basic elements – a blower, a high efficiency air
filter and a Plenum with a diffuser. The turbulent air upstream
should change to a Laminar flow by the filter, Plenum and
diffuser into straight-line flow off the downstream face of the
filter. Filtered air should descend in a uni-directional flow over
the patient, creating a “Clean Zone”, rapidly removing
contamination generated within that zone and preventing
entry of contaminated air. Average air velocity below the
plenum, should be 0.24 meters per second The Modular OT
system shall be supplied together with Vertical Laminar Air
Flow ceiling system only. The laminar box size shall be
minimum 3000mm x 3000mm for all the OTs with air volume
delivery should not be less than 7000 m3/h at discharge
velocity ranging between 0.24m/s to 0.30m/s maximum.
7. Design parameters:
Average air velocity below the plenum, be 0.24 meters per second
The laminar airflow ceiling shall have Filters of H14 grade, EN 1822 standard.
Double tight seat system to prevent leakages from sides of filter gaskets, filter frame and pressure frame.
Mini-perforated plate/sheet; the vertical flow should achieve homogeneous flow.
The vertical flow should ensure a sterile area of stable air hygiene over the operating table.
Laminar airflow system shall comply with internationally accepted standards & meet with ISO Class 5 requirements.
The air management system will be designed to achieved the following Parameters
Bacteriological class =B (10 CFU/m3)*
Particle decontamination kinetics CP =5 min
Biological decontamination kinetics CB = 5min
ISO 14644/1 classification = ISO 5
Certificate of country of origin and manufacturers test certificates to be submitted after installation
8. Automatic sealing Sliding Doors
All doors & door frames shall be made of stainless steel Material-Nr. 1.4301, SS 304 grade only.
Thickness of SS sheet used for door frame & door panel surfaces shall not be 1.5mm. There shall not
be any visible screws or similar other uneven surfaces on the door pane
All doors should have sturdy SS door handles on both sides. A lock shall be provided on each door.
All doors shall have vision panels (viewing window) at least 300mm x 300mm.
Automatic doors shall have potential equalization (earthing) as per VDE 0107 or equivalent
guaranteed by a sliding contact. Its automation unit shall be short-circuit proof and shall have an
integrated power supply unit 200-240V, 50-60 Hz, 24V~/2A and shall comply with ISO 9001 and CE
requirements.
There are two sizes required 2100mm x 1500mm & 2100mm x 900mm, SS door frame grid is to be
designed accordingly. The door leaf should have sealing system in closed position.
Vertically placed conductive push strip of minimum 1.0 mt height on both sides of the door for Auto
operation by elbow, foot or knee for entry / exit.
Separate entry push buttons for OT staff, trolley.
Dedicated push button on one side of door for cleaning purpose i.e. during cleaning area near OT
door, if required the said button is pressed which open the door will remain upon until pressed again.
All the buttons & conductive push strip mounted on SS door frame and pre-wired internally from
factory.
9. Surgical Pendant
Certified as per Medical Device Directives (93/42/EEC) having
the CE mark Class IIb medical device with notified number
specified. Third party certification to EN 60601 Medical
Equipment Electrical Safety.
Compliant to BS EN 7396 NHS health technical memorandum
model engineering specification from the certifying agency
with copy of certificate of origin
The Surgical Pendant is capable of lateral and vertical
movement, using a double arm system.
The pendant have an electro-magnetic braking system.
The Pendant have visual colored brake indicators to indicate
which joint movement has been released. It should fully
conform to HTM 02-01 Standards.
10. The Surgical Pendant have a compact service console, 900 mm in length and containing the
following services, fully installed and tested:
Front Mounted 38mm Multifunction Rack, providing accessory mounting and docking
solutions.
5 No. Shelves with 1 drawer each mounted on the multifunction Rack and edged with
Medical Rail. All shelves are fully height adjustable.
Rear Mounted Handle With Brake Controls.
10 No. 230V 13A Socket Outlets
2 No. Medical Oxygen Terminal Units
2 No. Medical Air 4 Bar Terminal Units
2 No. Surgical Air 7 Bar Terminal Units
2 No. Medical Vacuum Terminal Units
1 No. Medical carbon dioxide Terminal unit
1 No. Twin RJ45 Data Outlet
2 No. Single Gang Provisions for Data Services
The pay load of the pendant 200 kg.
11. Anesthetic Pendant
Certified as per Medical Device Directives (93/42/EEC) having the CE mark
Class IIb medical device with notified number specified. Third party certification
to EN 60601 Medical Equipment Electrical Safety.
Compliant to BS EN 7396 NHS health technical memorandum model
engineering specification from the certifying agency with copy of certificate of
origin
The Anesthetic Pendant capable of lateral and vertical movement, using a
single arm system
The pendant have an electro-magnetic braking system. The Pendant Arms have
visual colored brake indicators to indicate which joint movement has been
released.
It fully conform to HTM 02-01 Standards. Certificate of country of origin and
manufacturers test certificates to be submitted after installation
12. Pendant should have a compact service console, 900 mm in length and containing the following
services, fully installed and tested:
Front Mounted 38mm Multifunction Rack, providing accessory mounting and docking solutions.
3 No. Shelves mounted on the Multifunction Rack and edged with Medical Rail. All shelves are fully
height adjustable.
Rear Mounted Handle With Brake Controls.
10 No. 230V 13A Socket Outlets
2 No. Medical Oxygen Terminal Units
2 No. Medical Nitrous Oxide Terminal Units
2 No. Medical Air 4 Bar Terminal Units
2 No. Surgical Air 7 Bar Terminal Units
2 No. Medical Vacuum Terminal Units
1 No. Medical AGSS Terminal Unit
1 No. Medical Carbon Dioxide Terminal Units
1 No. Twin RJ45 Data Outlet
2 No. Single Gang Provisions for Data Services
The pay load of the pendant be 175kg.
The pendant have a wide range of maneuverability.
13. Modular Wall Panels
Surface clean room side made of be stainless steel 1.4301 (AISI 304), powder
coated, color white RAL 9010 or choice of color from shade card, with anti
microbiological coating to be provided
All the Operating Theatres be fully pre-fabricated and truly modular in design
having self-supporting, freestanding substructure.
The free standing substructure shall be made of GI of minimum 1.5mm sheet
thickness.
The substructure shall be firmly fixed onto the floor, slab/ceiling RCC with high
quality fasteners.
Substructure shall have additional horizontal support (mounting bracket) for
medical gases outlets, x-ray viewer, monitors etc. The wall substructure should be
calculated considering Floor to Slab height 3600mm
Wall cover panels made of Stainless steel (Material-Nr. 1.4301, SS 304 grade) of thickness not less than 1.0 mm. No other
material other than Stainless steel 304 grade shall be used for this purpose.
The SS wall panels shall be reinforced with 18mm non-flammable, high quality plaster board glued on the back of wall panels
to make a total thickness of 19 mm (1mm+18mm). Additional insulation to be provided, by high density mineral fiber mats
14.
15.
16. All the Wall panels, components of the structural material shall be totally prefabricated from the factory itself. All the wall
Panels shall be pre-powder coated and no painting job shall be carried out at site.
The pre-powder coating shall be maintained at a minimum deposit thickness of 60 microns and should have JIS Z 2801
certification from third party.
Wall and ceiling panels will be easily openable /closable for quick resumption of operations after repair/maintenance and for
future expansion and up-gradation.
Full height silicon rubber seal of Medical Grade shall be used to fill the gap between two wall panels to ensure a 100%
hermetically sealed vertical, flush with wall panels mounted joint. In all the corners of the OTs, especially fabricated, one
piece, angular SS wall panels shall be used.
The Modular OT wall system shall have certification for hygiene, noise protection, radiation protection & fire protection.
a) The fire resistance for single paneled wall system including substructure work should be class EI 30 (30 minutes
minimum) shall be in accordance with EN 13501-2, EI 1364-1
b) Metal structure work should be in accordance to DIN 18545.
c) CE compliance certification for all modular construction related components
d) The powder coating on wall panels should have third party (from reputed Lab) certification on compliance according to
JIS Z 2801 standard.
Certificate of country of origin and manufacturers test certificates to be submitted after installation
17. Modular False Ceiling
Clamping ceiling, cassette ceiling, galv. sheet steel 1.0 mm, non-perforated White wet-coated surface coffered ceiling
grid 600 x 600 mm or 1200 x 600 mm including substructure
Coating of the Ceiling Panel shall be not less than 40 micron with 180°C stove enameling and the color RAL 9010, Off-
white or powder coated.
The ceiling panels shall be secured by means of clip system and punched-in-knobs shall keep the panels in place and
shall ensure an exact ceiling level.
The panels are openable for future repair / maintenance & up-gradation. Certificate of country of origin and
manufacturers test certificates to be submitted after installation
18. X-ray view screen -
X-Ray viewing screen of size 1050x430mm
Four shutters for non-dazzling diagnostic use with flicker-
free HF light and variable control range of luminous
intensity,
Control range approx. 90%,
Flat film holders of silver anodized aluminum profile with
masked grip on all 4 sides of the viewing area.
19. 1. Writing cum List Board
Flush mounted white laminate board, opened to create a
wall mounted writing surface within the operating room.
The white board be constructed from white laminate board.
20. Clean-room luminaries with frame
Clean Room Luminaries, IP 65, recessed type to be provided in
OTs for general illumination.
6-8 nos. of IP-65 grade T16-lights, with dimming (intensity)
control, each light
1000 Lux illumination above 1 MTR floor level around the OT
table.
The light fixture will be hermetically sealed from top side
(ceiling side) have bottom opening for repair & maintenance.
Magnetic locking with the frame with no screws visible from
the bottom.
Certificate of country of origin and manufacturers test
certificates to be submitted after installation
21. 1. LED Operating Theatre Light
The Operating Theatre Light will comprise of a
double structure with 2 lamp heads (main and
satellite.)
The lamp heads have multiple LED light sources
including a combination of red and white LEDs to
optimize colour rendition
The light have a Comfort Halo, to reduce eye strain for surgeons by creating a more gradual change in contrast between
the illuminated area and areas under general lighting.
Each lamp head allows for a wireless link to a wall mounted remote control to repeat all controls and indicators including:
Lamp head On/Off Control
Intensity
Colour adjustment
Field Size
22. The Operating Theatre Light meet the following technical parameters:
Light Intensity – 160,000 Lux (Main) & 160,000 Lux (Satellite)
Light Field Diameter (d10) – 200-420mm (Adjustable)
Light Field Diameter (d50) – 120-250mm (Adjustable)
Beam Uniformity (d50/d10 Ratio) – 0.6
Comfort Halo – 2,000mm
Lamp Head Nominal Power Consumption – 48W
Radiant Energy mW/m².Lux - <3.31
IP Rating of Light Engine – 54
LED Life - >60,000 Hours
Color Rendition Index:
o Ra – 95
o R1 – 99
o R2 – 97
o R3 – 93
o R4 – 93
o R5 – 98
o R6 – 96
o R7 – 94
o R8 – 92
o R9 – 95
Red Balance Control to provide colour temperature of – 3100° K, 3400° K, 3700° K, 4100° K and 4600° K
Removable, Sterile Handle
Anti-Microbial Coating
Number of LED Light Sources: 90 (Main) + 39 (sat)
Certificate of country of origin and manufacturers test certificates to be submitted after installation
23. HD Camera for OT Light
Integrated camera to be fully enclosed within the lamp head and behind the OT lamp protective front lens in order to
provide a permanent, robust and secure solution with reliable connectivity.
Direct Digital technology transmit a 1080i HDSDI signal directly from the camera, without processing or scaling, loss of
resolution or image detail.
Zoom controls provided on the lamp head.
Option for full camera control via a secure wireless remote control including control of:
Zoom control
Auto/Manual Focus
Auto/Manual Iris
White Balance Control
Freeze Image
Black and White / Colour Selection
Digital Zoom Enable/Disable Selection
24. HD Camera System comply with the following technical parameters :
Effective picture elements - Approx 2,000,000 pixels
Video Signal - HDSDI: 1080i/59.94
Lens - 10x zoom F1.8 to F2.1)
F=5.1 mm (WIDE) to 51 mm (TELE)
Zoom movement speed
Optical WIDE/Optical TELE 1.0 sec
Optical WIDE/Digital 4x TELE 1.5 sec
Digital WIDE/Digital 4x TELE 0.5 sec
Focus Movement °° to Near 0.1 sec
Digital zoom - 12x (120x with optical zoom)
Angle of view (H) - 50 degree (WIDE end) to 5.4 degree (TELE end)
Min. object distance - 10 mm (WIDE end), 800 mm (TELE end)
Min. illumination (Typical) - 12 lux (F1.8) with 50 IRE
1.0 lux ICR On (F1.8) with 50 IRE
S/N ratio - 50 dB or more
Electronic shutter speed - 1/2 to 1/10000 sec. (21 steps)
White balance - AUTO, WB/Indoor/Outdoor/One Push WB/Manual WB
Gain - Auto/Manual (-3 to +18 dB, 8 steps)
AE control - Full Auto/Shutter Priority/Iris Priority/Manual/Bright/Spot AE
Exposure compensation - ± 10.5 dB (15 steps in a unit of 1.5 dB)
Aperture control - 16 steps
Picture effect - Black & white, still image (frozen)
Focus - Full Manual / Auto (Normal AF/ Interval AF/ Zoom Trigger AF)
Camera Control interface - External communications via Medical Secure i2i wireless interface.
Storage temperature/Humidity - -20 to 60°C (-4 to 140°F)/20 to 95%
Operating temperature/Humidity - 0 to 45°C (32 to 113°F)/20 to 80%
Power requirements/Power consumption - 6 to 12 V DC/4.8 W. Powered from OT light medical safety power supply. Fully powered during
emergency battery operation
25. HD Monitor
High Definition with dimension of 22”. Monitor medically approved with easy controls
via OSD Jog wheel interface
Edge to edge non-reflecting glass surface making it hygienic and easy to clean.
26. The monitor conform to the following parameters :
Screen Design - True Flat design with edge
to edge wipe clean protection glass with AG coating
User Controls - Jog wheel control and On screen
GUI Size - 21.5” / 54.6 cm
Panel backlight - LED
Aspect ratio - 16:9
Active area (H × V) - 476.5 × 268.11 mm
Resolution - 1920 × 1080
Pixel pitch - 0.248 × 0.248
Display colours - 16.7 M
Luminance/Brightness - 300 cd/m2 typ.
Contrast ratio - 5000:1
Viewing angle (H × V) - 178° / 178°
Response time typ. - 16 ms
Video Input Ports - HD-SDI (3G), DVI
Power consumption - ~30 W
Dimensions (W × H × D) - 537.4 × 384.4 × 175.0 mm
Temperature operating - +10 °C to +40 °C
Humidity operating - 30 to 75 % RH
Power supply - 24 VDC
Mounting - VESA 100
Regulatory Compliance - EN 60601-1 3rd; UL60601-1
3rd, RoHS
Certificate of country of origin and manufacturers test
certificates to be submitted after installation
27. Storage Unit:
Storage cabinet of dimension 2100 x 900 x 600 (HxWxD) mm
The storage cabinet shall be made of SS specification, same as used for wall panel,
The door panels of the cabinet shall be in Stainless steel & partly in tempered glass.
The storage Cabinet should have 4 trays. Certificate of country of origin and manufacturers test
certificates to be submitted after installation
28. Scrub Station:
Two bay scrub station shall be made of stainless steel Material-Nr. 1.4301, SS 304 grade
with minimum 1.25mm thickness.
Each sink of the scrub station have two soap dispensers and a tap operated with an
independent optical sensor with timer mode. The tap have an automatic mixer for hot &
cold water through a temperature regulator.
29. Pass Through Box
Pass Through box of dimension 600mm (width) x 600 mm (Height) x 600mm (Depth).
Made of SS 1.4301 (304 grades), thickness of the sheet to be used is 1.25 mm.
The door panels of Stainless steel and partly in glass.
Both doors electro-mechanically interlocked so that only one side door could be
opened at a time.
Certificate of country of origin and manufacturers test certificates to be submitted after
installation
30. HEPA Filter Air Outlets
H13 grade, according to DIN EN 1822 standard complying with DIN 1946-4 standard, to be provided.
Each Air filter capable to deliver 550m³/h air volume, pressure drop 130Pa
Filter Frame made of extruded aluminum & factory testing for Leakage
Filters are fitted with a lip seal into an installation sub frame with two or four fixing points.
Equipped with a sealing integrity test facility, internal measuring tube, and pressure measurement point for monitoring
the operating differential pressure. Suspension and pressure measurement points either at the side or at the top.
Casing made of sheet steel, powder-coated RAL 9010, pure white
diffusers made of sheet steel, powder-coated RAL 9010
Air-filter Outlet size:
Nominal size: 625mm
Connection diameter: 248mm
Height of the casing: 384mm
Certificate of country of origin and manufacturers test certificates to be submitted after installation
31. Description Plain Plates Survival Time Coating Killing Time
Staphylococcus Aureus Type 80/8 24Hrs 1Hr
Escherichia Coli NCTC 10418 24Hrs 1-2Hrs
Pseudomonas Aeruginosa 24Hrs 4-5Hrs
Beta Hemolytic Streptococcus 5-24Hrs 3Hrs
Salmonella Typimurium 24Hrs 4-5Hrs
Candida Albicans (Fungus) 24Hrs 2-3Hrs
•Antibacterial wall paint
Following Killing Time for most commonly found microbes in Operation Theater