SlideShare a Scribd company logo
1 of 5
Download to read offline
Standard Motor Starters 
Series 8220 
E7 
E7 
E7 
E7 
E7 
www.stahl.de Load Disconnect Switches and Motor Starters E7/1 2014-07-02·EK00·III·en 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
Series 8220 E7 
10102E00 
WebCode 8220A 
> Enclosure with 
type of protection Ex d and 
terminal compartment enclosure 
with Ex e 
> Available standard motor 
controllers 
– Direct-on-line motor starters 
DOL 
– Star-delta starter 
combinations YD 
– Reversing starter 
combinations 
> Advantage 
– short delivery times 
The standard motor starters are fitted into enclosures with 
type of protection "flameproof enclosure". 
The standard starters are supplied without main switch, main fuses 
and without control and monitoring devices. These parts can be 
fitted to order. 
ATEX / IECEx 
Zone 0 1 2 20 21 22 
For use in x x x x
Standard Motor Starters, Direct On-Line Motor Starters DOL 
Series 8220 
Explosion Protection 
Global (IECEx) 
Gas IECEx PTB 06.0069 
Ex de [ia/ib] IIC T6, T5, T4 
Dust IECEx PTB 06.0069 
Ex tD A21 IP6X T80°C, T95°C, T130°C 
Europe (ATEX) 
Gas and dust PTB 02 ATEX 1109 
E II 2 G Ex de [ia/ib] IIC T6, T5, T4 
E II 2 D Ex tD A21 IP66 T80°C, T95°C, T130°C 
Certifications and certificates 
Certificates IECEx, ATEX, Kazakhstan (TR), Korea (KCs), Russia (TR), Belarus (TR) 
Technical Data 
Electrical data 
Rated voltage 400 V AC 
Control voltage 230 V AC 
Circuit diagram 
09805E00 
Ambient conditions 
Ambient temperature -20 ... +40 °C 
Mechanical data 
Degree of protection IP55 (to order IP65) 
Enclosure material Sheet steel, cover: die-cast alloy / stainless steel 
Colour Enclosure: grey, RAL 7032, cover: dark grey, RAL 7022 
Note 
Note Description: Single contactor for connecting and disconnecting the motor circuits and ohmic consumers. 
With thermal overcurrent release, version with control transformer acc. to EN 60204. Specify on order if 
the nominal voltage has a different value than 400 V because the transformer must then be selected 
appropriately. 
Direct On-Line Motor Starters DOL 
Selection Table 
Switching 
capacity 
400 V AC-3 
Ex d 
enclosure Terminals Cable entries bottom Order number 
5.5 kW 8220/112 4 x 6 mm2 3 x 4 mm2 2 x M32 2 x M25 8220/5-SM-ES5,5kW400V-T 
7.5 kW 8220/112 4 x 10 mm2 3 x 6 mm2 2 x M32 2 x M25 8220/5-SM-ES7,5kW400V-T 
11 kW 8220/112 4 x 10 mm2 3 x 6 mm2 2 x M32 2 x M25 8220/5-SM-ES11kW400V-T 
15 kW 8220/112 4 x 16 mm2 3 x 6 mm2 2 x M32 2 x M25 8220/5-SM-ES15kW400V-T 
18.5 kW 8220/112 4 x 16 mm2 3 x 10 mm2 2 x M32 2 x M25 8220/5-SM-ES18,5kW400V-T 
22 kW 8220/112 4 x 35 mm2 3 x 10 mm2 1 x M40 1 x M32 2 x M25 8220/5-SM-ES22kW400V-T 
30 kW 8220/122 4 x 35 mm2 3 x 16 mm2 1 x M40 1 x M32 2 x M25 8220/5-SM-ES30kW400V-T 
37 kW 8220/122 4 x 35 mm2 3 x 16 mm2 1 x M40 1 x M32 2 x M25 8220/5-SM-ES37kW400V-T 
45 kW 8220/122 4 x 50 mm2 3 x 35 mm2 1 x M50 1 x M40 2 x M25 8220/5-SM-ES45kW400V-T 
55 kW 8220/122 4 x 50 mm2 3 x 35 mm2 1 x M50 1 x M40 2 x M25 8220/5-SM-ES55kW400V-T 
75 kW 8220/122 4 x 50 mm2 3 x 35 mm2 1 x M50 1 x M40 2 x M25 8220/5-SM-ES75kW400V-T 
E7/2 Load Disconnect Switches and Motor Starters 2014-07-02·EK00·III·en
Standard Motor Starters, Star-Delta Contactor Starters YD 
Series 8220 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
Explosion Protection 
Global (IECEx) 
Gas IECEx PTB 06.0069 
Ex de [ia/ib] IIC T6, T5, T4 
Dust IECEx PTB 06.0069 
Ex tD A21 IP6X T80°C, T95°C, T130°C 
Europe (ATEX) 
Gas and dust PTB 02 ATEX 1109 
E II 2 G Ex de [ia/ib] IIC T6, T5, T4 
E II 2 D Ex tD A21 IP66 T80°C, T95°C, T130°C 
Certifications and certificates 
Certificates IECEx, ATEX, Kazakhstan (TR), Korea (KCs), Russia (TR), Belarus (TR) 
Technical Data 
Electrical data 
Rated voltage 400 V AC 
Control voltage 230 V AC 
Circuit diagram 
09806E00 
Ambient conditions 
Ambient temperature -20 ... +40 °C 
Mechanical data 
Degree of protection IP55 (to order IP65) 
Enclosure material Sheet steel, cover: die-cast alloy / stainless steel 
Colour Enclosure: grey, RAL 7032, cover: dark grey, RAL 7022 
Note 
Note Description: 
Contactor combination for connecting and disconnecting the motor circuits and ohmic consumers. 
With thermal overcurrent release, version with control transformer acc. to EN 60204. Specify on order if 
the nominal voltage has a different value than 400 V because the transformer must then be selected 
appropriately. 
Star-Delta Starter Combinations YD 
Selection Table 
Switching 
capacity 
400 V AC-3 
Ex d 
enclosure Terminals Cable entries bottom Order number 
11 kW 8220/122 4 x 6 mm2 6 x 4 mm2 3 x M32 2 x M25 8220/5-SL-SS11kW400V-T 
15 kW 8220/122 4 x 6 mm2 6 x 4 mm2 3 x M32 2 x M25 8220/5-SL-SS15kW400V-T 
18.5 kW 8220/122 4 x 6 mm2 6 x 4 mm2 3 x M32 2 x M25 8220/5-SL-SS18,5kW400V-T 
22 kW 8220/122 4 x 10 mm2 6 x 6 mm2 3 x M32 2 x M25 8220/5-SL-SS22kW400V-T 
30 kW 8220/172 4 x 16 mm2 6 x 6 mm2 3 x M40 2 x M25 8220/5-SL-SS30kW400V-T 
37 kW 8220/172 4 x 35 mm2 6 x 10 mm2 3 x M40 2 x M25 8220/5-SL-SS37kW400V-T 
45 kW 8220/132 4 x 35 mm2 6 x 16 mm2 1 x M50 2 x M40 2 x M25 8220/5-SL-SS45kW400V-T 
55 kW 8220/132 4 x 50 mm2 6 x 35 mm2 1 x M50 2 x M40 2 x M25 8220/5-SL-SS55kW400V-T 
75 kW 8220/132 4 x 50 mm2 6 x 35 mm2 1 x M50 2 x M40 2 x M25 8220/5-SL-SS75kW400V-T 
90 kW 8220/133 4 x 95 mm2 6 x 50 mm2 1 x M63 2 x M40 2 x M25 8220/5-SL-SS90kW400V-T 
110 kW 8220/133 4 x 150 mm2 6 x 95 mm2 1 x M63 2 x M50 2 x M25 8220/5-SL-SS110kW400V-T 
132 kW 8220/133 4 x 150 mm2 6 x 95 mm2 1 x M63 2 x M50 2 x M25 8220/5-SL-SS132kW400V-T 
160 kW 8220/196 4 x 240 mm2 6 x 150 mm2 3 x M63 2 x M25 8220/5-SL-SS160kW400V-T 
200 kW 8220/196 4 x 240 mm2 6 x 150 mm2 3 x M63 2 x M25 8220/5-SL-SS200kW400V-T 
2014-07-02·EK00·III·en Load Disconnect Switches and Motor Starters E7/3
Standard Motor Starters, Reversing Starter Combinations 
Series 8220 
Explosion Protection 
Global (IECEx) 
Gas IECEx PTB 06.0069 
Ex de [ia/ib] IIC T6, T5, T4 
Dust IECEx PTB 06.0069 
Ex tD A21 IP6X T80°C, T95°C, T130°C 
Europe (ATEX) 
Gas and dust PTB 02 ATEX 1109 
E II 2 G Ex de [ia/ib] IIC T6, T5, T4 
E II 2 D Ex tD A21 IP66 T80°C, T95°C, T130°C 
Certifications and certificates 
Certificates IECEx, ATEX, Kazakhstan (TR), Korea (KCs), Russia (TR), Belarus (TR) 
Technical Data 
Electrical data 
Rated voltage 400 V AC 
Control voltage 230 V AC 
Circuit diagram 
10043E00 
Ambient conditions 
Ambient temperature -20 ... +40 °C 
Mechanical data 
Degree of protection IP55 (to order IP65) 
Enclosure material Sheet steel, cover: die-cast alloy / stainless steel 
Colour Enclosure: grey, RAL 7032, cover: dark grey, RAL 7022 
Note 
Note Description: Contactor combination for changing the phase sequence of the motor circuits. With thermal 
overcurrent release, version with control transformer acc. to EN 60204. Specify on order if the nominal 
voltage has a different value than 400 V because the transformer must then be selected appropriately. 
Reversing Starter Combinations 
Selection Table 
Switching 
capacity 
400 V AC-3 
Ex d 
enclosure Terminals Cable entries bottom Order number 
5.5 kW 8220/122 4 x 6 mm2 3 x 4 mm2 2 x M32 2 x M25 8220/5-SL-WS5,5kW400V-T 
7.5 kW 8220/122 4 x 6 mm2 3 x 4 mm2 2 x M32 2 x M25 8220/5-SL-WS7,5kW400V-T 
11 kW 8220/122 4 x 10 mm2 3 x 6 mm2 2 x M32 2 x M25 8220/5-SL-WS11kW400V-T 
15 kW 8220/122 4 x 16 mm2 3 x 6 mm2 2 x M32 2 x M25 8220/5-SL-WS15kW400V-T 
18.5 kW 8220/122 4 x 16 mm2 3 x 10 mm2 2 x M32 2 x M25 8220/5-SL-WS18,5kW400V-T 
22 kW 8220/122 4 x 35 mm2 3 x 16 mm2 1 x M40 1 x M32 2 x M25 8220/5-SL-WS22kW400V-T 
30 kW 8220/122 4 x 35 mm2 3 x 16 mm2 1 x M40 1 x M32 2 x M25 8220/5-SL-WS30kW400V-T 
37 kW 8220/122 4 x 50 mm2 3 x 35 mm2 1 x M40 1 x M32 2 x M25 8220/5-SL-WS37kW400V-T 
45 kW 8220/122 4 x 95 mm2 3 x 35 mm2 1 x M50 1 x M40 2 x M25 8220/5-SL-WS45kW400V-T 
55 kW 8220/133 4 x 95 mm2 3 x 50 mm2 1 x M50 1 x M40 2 x M25 8220/5-SL-WS55kW400V-T 
75 kW 8220/133 4 x 95 mm2 3 x 95 mm2 1 x M63 1 x M50 2 x M25 8220/5-SL-WS75kW400V-T 
E7/4 Load Disconnect Switches and Motor Starters 2014-07-02·EK00·III·en
Standard Motor Starters 
Series 8220 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
E7 
Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 
04470E00 
8220/112 
04471E00 
8220/122 
04472E00 
8220/172 
04474E00 
8220/132 
04475E00 
8220/133 
04477E00 
8220/196 
We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. 
The illustrations cannot be considered binding. 
2014-07-02·EK00·III·en Load Disconnect Switches and Motor Starters E7/5

More Related Content

What's hot

Stahl 6100/6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area Li...
Stahl 6100/6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area Li...Stahl 6100/6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area Li...
Stahl 6100/6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area Li...Thorne & Derrick International
 
Stahl C-Lux 6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area L...
Stahl C-Lux 6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area L...Stahl C-Lux 6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area L...
Stahl C-Lux 6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area L...Thorne & Derrick International
 
Inertia dynamic type fsbr_specsheet
Inertia dynamic type fsbr_specsheetInertia dynamic type fsbr_specsheet
Inertia dynamic type fsbr_specsheetElectromate
 
Inertia dynamics wrapspring_dcb8sm_specsheet
Inertia dynamics wrapspring_dcb8sm_specsheetInertia dynamics wrapspring_dcb8sm_specsheet
Inertia dynamics wrapspring_dcb8sm_specsheetElectromate
 
Cataloge ge 3.control and_automation_dienhathe.com-4_04_vat300_e_c2-3_rev_b
Cataloge ge 3.control and_automation_dienhathe.com-4_04_vat300_e_c2-3_rev_bCataloge ge 3.control and_automation_dienhathe.com-4_04_vat300_e_c2-3_rev_b
Cataloge ge 3.control and_automation_dienhathe.com-4_04_vat300_e_c2-3_rev_bDien Ha The
 
Rx king part katalog catalog Indonesia
Rx king part katalog catalog IndonesiaRx king part katalog catalog Indonesia
Rx king part katalog catalog IndonesiaPead Motor
 
Delta Open Frame Power Supply Brochure (Rev. March 2014)
Delta Open Frame Power Supply Brochure (Rev. March 2014)Delta Open Frame Power Supply Brochure (Rev. March 2014)
Delta Open Frame Power Supply Brochure (Rev. March 2014)Delta Electronics Power Supply
 
Burkert MKEN 1060 > นิวเมติก.com
Burkert MKEN 1060 > นิวเมติก.comBurkert MKEN 1060 > นิวเมติก.com
Burkert MKEN 1060 > นิวเมติก.comDNTMb Inc.
 
Lucy Zodion Trojan Street Lighting Isolators - Trojan2 Midi 2/3 Way Modular S...
Lucy Zodion Trojan Street Lighting Isolators - Trojan2 Midi 2/3 Way Modular S...Lucy Zodion Trojan Street Lighting Isolators - Trojan2 Midi 2/3 Way Modular S...
Lucy Zodion Trojan Street Lighting Isolators - Trojan2 Midi 2/3 Way Modular S...Thorne & Derrick International
 
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood LightZone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood LightThorne & Derrick International
 

What's hot (11)

Stahl 6100/6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area Li...
Stahl 6100/6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area Li...Stahl 6100/6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area Li...
Stahl 6100/6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area Li...
 
Stahl C-Lux 6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area L...
Stahl C-Lux 6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area L...Stahl C-Lux 6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area L...
Stahl C-Lux 6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area L...
 
Inertia dynamic type fsbr_specsheet
Inertia dynamic type fsbr_specsheetInertia dynamic type fsbr_specsheet
Inertia dynamic type fsbr_specsheet
 
Inertia dynamics wrapspring_dcb8sm_specsheet
Inertia dynamics wrapspring_dcb8sm_specsheetInertia dynamics wrapspring_dcb8sm_specsheet
Inertia dynamics wrapspring_dcb8sm_specsheet
 
Cataloge ge 3.control and_automation_dienhathe.com-4_04_vat300_e_c2-3_rev_b
Cataloge ge 3.control and_automation_dienhathe.com-4_04_vat300_e_c2-3_rev_bCataloge ge 3.control and_automation_dienhathe.com-4_04_vat300_e_c2-3_rev_b
Cataloge ge 3.control and_automation_dienhathe.com-4_04_vat300_e_c2-3_rev_b
 
Rx king part katalog catalog Indonesia
Rx king part katalog catalog IndonesiaRx king part katalog catalog Indonesia
Rx king part katalog catalog Indonesia
 
Vlt3000
Vlt3000Vlt3000
Vlt3000
 
Delta Open Frame Power Supply Brochure (Rev. March 2014)
Delta Open Frame Power Supply Brochure (Rev. March 2014)Delta Open Frame Power Supply Brochure (Rev. March 2014)
Delta Open Frame Power Supply Brochure (Rev. March 2014)
 
Burkert MKEN 1060 > นิวเมติก.com
Burkert MKEN 1060 > นิวเมติก.comBurkert MKEN 1060 > นิวเมติก.com
Burkert MKEN 1060 > นิวเมติก.com
 
Lucy Zodion Trojan Street Lighting Isolators - Trojan2 Midi 2/3 Way Modular S...
Lucy Zodion Trojan Street Lighting Isolators - Trojan2 Midi 2/3 Way Modular S...Lucy Zodion Trojan Street Lighting Isolators - Trojan2 Midi 2/3 Way Modular S...
Lucy Zodion Trojan Street Lighting Isolators - Trojan2 Midi 2/3 Way Modular S...
 
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood LightZone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
 

Viewers also liked

Boddingtons Electrical Cable Jointing Tools & Safety Eqpt
Boddingtons Electrical Cable Jointing Tools & Safety EqptBoddingtons Electrical Cable Jointing Tools & Safety Eqpt
Boddingtons Electrical Cable Jointing Tools & Safety EqptThorne & Derrick International
 
Ecom CK7X ATEX Certified Hazardous Area PDA (Mobile Computer) Datasheet
Ecom CK7X ATEX Certified Hazardous Area PDA (Mobile Computer) DatasheetEcom CK7X ATEX Certified Hazardous Area PDA (Mobile Computer) Datasheet
Ecom CK7X ATEX Certified Hazardous Area PDA (Mobile Computer) DatasheetThorne & Derrick International
 
Craig and Derricott Isolators And Switch Disconnectors
Craig and Derricott Isolators And Switch DisconnectorsCraig and Derricott Isolators And Switch Disconnectors
Craig and Derricott Isolators And Switch DisconnectorsThorne & Derrick International
 
Ellis Patents VRT+13 Vulcan Stainless Steel Cable Cleats
Ellis Patents VRT+13 Vulcan Stainless Steel Cable CleatsEllis Patents VRT+13 Vulcan Stainless Steel Cable Cleats
Ellis Patents VRT+13 Vulcan Stainless Steel Cable CleatsThorne & Derrick International
 
Surge Protection - Main Incoming Supply Sub Distribution Boards Socket Outlet...
Surge Protection - Main Incoming Supply Sub Distribution Boards Socket Outlet...Surge Protection - Main Incoming Supply Sub Distribution Boards Socket Outlet...
Surge Protection - Main Incoming Supply Sub Distribution Boards Socket Outlet...Thorne & Derrick International
 
IEC61482 Box Method For Testing Clothing PPE Against Thermal Hazards Of An E...
IEC61482 Box Method For Testing Clothing PPE Against Thermal Hazards Of  An E...IEC61482 Box Method For Testing Clothing PPE Against Thermal Hazards Of  An E...
IEC61482 Box Method For Testing Clothing PPE Against Thermal Hazards Of An E...Thorne & Derrick International
 
Stahl 6161 Flashing Beacon Signalling Device – ATEX Zone 1 Zone 2 Hazardous A...
Stahl 6161 Flashing Beacon Signalling Device – ATEX Zone 1 Zone 2 Hazardous A...Stahl 6161 Flashing Beacon Signalling Device – ATEX Zone 1 Zone 2 Hazardous A...
Stahl 6161 Flashing Beacon Signalling Device – ATEX Zone 1 Zone 2 Hazardous A...Thorne & Derrick International
 
Stahl 6050 Pendant Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6050 Pendant Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6050 Pendant Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6050 Pendant Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area LightingThorne & Derrick International
 
Stahl 6600 Fluorescent Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Ligh...
Stahl 6600 Fluorescent Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Ligh...Stahl 6600 Fluorescent Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Ligh...
Stahl 6600 Fluorescent Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Ligh...Thorne & Derrick International
 
Ellis Patents VRT+00 Vulcan Stainless Steel Cable Cleats
Ellis Patents VRT+00 Vulcan Stainless Steel Cable CleatsEllis Patents VRT+00 Vulcan Stainless Steel Cable Cleats
Ellis Patents VRT+00 Vulcan Stainless Steel Cable CleatsThorne & Derrick International
 
Craig and Derricott - Isolators, Switch Disconnectors & LV Control Gear (Indu...
Craig and Derricott - Isolators, Switch Disconnectors & LV Control Gear (Indu...Craig and Derricott - Isolators, Switch Disconnectors & LV Control Gear (Indu...
Craig and Derricott - Isolators, Switch Disconnectors & LV Control Gear (Indu...Thorne & Derrick International
 
Abtech ZAG9 Aluminium Electrical Enclosure & Junction Box
Abtech ZAG9 Aluminium Electrical Enclosure & Junction BoxAbtech ZAG9 Aluminium Electrical Enclosure & Junction Box
Abtech ZAG9 Aluminium Electrical Enclosure & Junction BoxThorne & Derrick International
 
CATU Live Line Working Tools, Gloves & Electrical Safety - LV 33kV 132kV 275k...
CATU Live Line Working Tools, Gloves & Electrical Safety - LV 33kV 132kV 275k...CATU Live Line Working Tools, Gloves & Electrical Safety - LV 33kV 132kV 275k...
CATU Live Line Working Tools, Gloves & Electrical Safety - LV 33kV 132kV 275k...Thorne & Derrick International
 
Cembre - Cable Crimps, Connectors, Splices, Glands & Tools
Cembre - Cable Crimps, Connectors, Splices, Glands & ToolsCembre - Cable Crimps, Connectors, Splices, Glands & Tools
Cembre - Cable Crimps, Connectors, Splices, Glands & ToolsThorne & Derrick International
 

Viewers also liked (19)

Boddingtons Electrical Cable Jointing Tools & Safety Eqpt
Boddingtons Electrical Cable Jointing Tools & Safety EqptBoddingtons Electrical Cable Jointing Tools & Safety Eqpt
Boddingtons Electrical Cable Jointing Tools & Safety Eqpt
 
Ecom CK7X ATEX Certified Hazardous Area PDA (Mobile Computer) Datasheet
Ecom CK7X ATEX Certified Hazardous Area PDA (Mobile Computer) DatasheetEcom CK7X ATEX Certified Hazardous Area PDA (Mobile Computer) Datasheet
Ecom CK7X ATEX Certified Hazardous Area PDA (Mobile Computer) Datasheet
 
Craig and Derricott Isolators And Switch Disconnectors
Craig and Derricott Isolators And Switch DisconnectorsCraig and Derricott Isolators And Switch Disconnectors
Craig and Derricott Isolators And Switch Disconnectors
 
Ellis Patents VRT+13 Vulcan Stainless Steel Cable Cleats
Ellis Patents VRT+13 Vulcan Stainless Steel Cable CleatsEllis Patents VRT+13 Vulcan Stainless Steel Cable Cleats
Ellis Patents VRT+13 Vulcan Stainless Steel Cable Cleats
 
Thomas and Betts Cable Crimping Tools
Thomas and Betts Cable Crimping ToolsThomas and Betts Cable Crimping Tools
Thomas and Betts Cable Crimping Tools
 
Surge Protection - Main Incoming Supply Sub Distribution Boards Socket Outlet...
Surge Protection - Main Incoming Supply Sub Distribution Boards Socket Outlet...Surge Protection - Main Incoming Supply Sub Distribution Boards Socket Outlet...
Surge Protection - Main Incoming Supply Sub Distribution Boards Socket Outlet...
 
IEC61482 Box Method For Testing Clothing PPE Against Thermal Hazards Of An E...
IEC61482 Box Method For Testing Clothing PPE Against Thermal Hazards Of  An E...IEC61482 Box Method For Testing Clothing PPE Against Thermal Hazards Of  An E...
IEC61482 Box Method For Testing Clothing PPE Against Thermal Hazards Of An E...
 
Kingsmill Copper Earth Bars - 24 Way
Kingsmill Copper Earth Bars - 24 WayKingsmill Copper Earth Bars - 24 Way
Kingsmill Copper Earth Bars - 24 Way
 
Stahl 6161 Flashing Beacon Signalling Device – ATEX Zone 1 Zone 2 Hazardous A...
Stahl 6161 Flashing Beacon Signalling Device – ATEX Zone 1 Zone 2 Hazardous A...Stahl 6161 Flashing Beacon Signalling Device – ATEX Zone 1 Zone 2 Hazardous A...
Stahl 6161 Flashing Beacon Signalling Device – ATEX Zone 1 Zone 2 Hazardous A...
 
Stahl 6050 Pendant Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6050 Pendant Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6050 Pendant Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6050 Pendant Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Lighting
 
Ellis Patents Vulcan Cleat VRT+07
Ellis Patents Vulcan Cleat VRT+07Ellis Patents Vulcan Cleat VRT+07
Ellis Patents Vulcan Cleat VRT+07
 
Stahl 6600 Fluorescent Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Ligh...
Stahl 6600 Fluorescent Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Ligh...Stahl 6600 Fluorescent Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Ligh...
Stahl 6600 Fluorescent Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area Ligh...
 
Ellis Patents VRT+00 Vulcan Stainless Steel Cable Cleats
Ellis Patents VRT+00 Vulcan Stainless Steel Cable CleatsEllis Patents VRT+00 Vulcan Stainless Steel Cable Cleats
Ellis Patents VRT+00 Vulcan Stainless Steel Cable Cleats
 
CATU Lockout Tagout Solutions - Locking Padlocks
CATU Lockout Tagout Solutions - Locking PadlocksCATU Lockout Tagout Solutions - Locking Padlocks
CATU Lockout Tagout Solutions - Locking Padlocks
 
Craig and Derricott - Isolators, Switch Disconnectors & LV Control Gear (Indu...
Craig and Derricott - Isolators, Switch Disconnectors & LV Control Gear (Indu...Craig and Derricott - Isolators, Switch Disconnectors & LV Control Gear (Indu...
Craig and Derricott - Isolators, Switch Disconnectors & LV Control Gear (Indu...
 
Earth Bonding Kits - 3M
Earth Bonding Kits - 3MEarth Bonding Kits - 3M
Earth Bonding Kits - 3M
 
Abtech ZAG9 Aluminium Electrical Enclosure & Junction Box
Abtech ZAG9 Aluminium Electrical Enclosure & Junction BoxAbtech ZAG9 Aluminium Electrical Enclosure & Junction Box
Abtech ZAG9 Aluminium Electrical Enclosure & Junction Box
 
CATU Live Line Working Tools, Gloves & Electrical Safety - LV 33kV 132kV 275k...
CATU Live Line Working Tools, Gloves & Electrical Safety - LV 33kV 132kV 275k...CATU Live Line Working Tools, Gloves & Electrical Safety - LV 33kV 132kV 275k...
CATU Live Line Working Tools, Gloves & Electrical Safety - LV 33kV 132kV 275k...
 
Cembre - Cable Crimps, Connectors, Splices, Glands & Tools
Cembre - Cable Crimps, Connectors, Splices, Glands & ToolsCembre - Cable Crimps, Connectors, Splices, Glands & Tools
Cembre - Cable Crimps, Connectors, Splices, Glands & Tools
 

Similar to Stahl 8220 Star Reversing Starter Motor Starters - ATEX Zone 1 Zone 2 Hazardous Area

Stahl 8264 CUBEx Reversing Starter Motor Starters – ATEX Zone 1 Zone 2 Hazard...
Stahl 8264 CUBEx Reversing Starter Motor Starters – ATEX Zone 1 Zone 2 Hazard...Stahl 8264 CUBEx Reversing Starter Motor Starters – ATEX Zone 1 Zone 2 Hazard...
Stahl 8264 CUBEx Reversing Starter Motor Starters – ATEX Zone 1 Zone 2 Hazard...Thorne & Derrick International
 
Stahl 8264 CUBEx Direct Online (DOL) Motor Starter – ATEX Zone 1 Zone 2 Hazar...
Stahl 8264 CUBEx Direct Online (DOL) Motor Starter – ATEX Zone 1 Zone 2 Hazar...Stahl 8264 CUBEx Direct Online (DOL) Motor Starter – ATEX Zone 1 Zone 2 Hazar...
Stahl 8264 CUBEx Direct Online (DOL) Motor Starter – ATEX Zone 1 Zone 2 Hazar...Thorne & Derrick International
 
Stahl 8264 CUBEx Star Delta Motor Starter – ATEX Zone 1 Zone 2 Hazardous Area
Stahl 8264 CUBEx Star Delta Motor Starter – ATEX Zone 1 Zone 2 Hazardous Area Stahl 8264 CUBEx Star Delta Motor Starter – ATEX Zone 1 Zone 2 Hazardous Area
Stahl 8264 CUBEx Star Delta Motor Starter – ATEX Zone 1 Zone 2 Hazardous Area Thorne & Derrick International
 
Switchtec Din Rail Terminal Brochure
Switchtec Din Rail Terminal BrochureSwitchtec Din Rail Terminal Brochure
Switchtec Din Rail Terminal BrochureAndy Birdsall
 
Catalog hitachi hitachi switch&breaders ctlg eng-dienhathe.org
Catalog hitachi hitachi switch&breaders ctlg eng-dienhathe.orgCatalog hitachi hitachi switch&breaders ctlg eng-dienhathe.org
Catalog hitachi hitachi switch&breaders ctlg eng-dienhathe.orgDien Ha The
 
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...Thorne & Derrick International
 
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...Thorne & Derrick International
 
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...Thorne & Derrick International
 
Stahl Lighting ECOLUX 6600 Light Fitting For Fluorescent Lamps – ATEX Zone 1 ...
Stahl Lighting ECOLUX 6600 Light Fitting For Fluorescent Lamps – ATEX Zone 1 ...Stahl Lighting ECOLUX 6600 Light Fitting For Fluorescent Lamps – ATEX Zone 1 ...
Stahl Lighting ECOLUX 6600 Light Fitting For Fluorescent Lamps – ATEX Zone 1 ...Thorne & Derrick International
 
Kraus & naimer emc-co mpliant conne-ction-kn_emc_gb_dienhathe.vn
Kraus & naimer emc-co mpliant conne-ction-kn_emc_gb_dienhathe.vnKraus & naimer emc-co mpliant conne-ction-kn_emc_gb_dienhathe.vn
Kraus & naimer emc-co mpliant conne-ction-kn_emc_gb_dienhathe.vnDien Ha The
 
Magnetic contactors and magnetic starters ms-t series dienhathe.org
Magnetic contactors and magnetic starters ms-t series dienhathe.orgMagnetic contactors and magnetic starters ms-t series dienhathe.org
Magnetic contactors and magnetic starters ms-t series dienhathe.orgDien Ha The
 
Dienhathe.com semiconductor fuses
Dienhathe.com semiconductor fusesDienhathe.com semiconductor fuses
Dienhathe.com semiconductor fusesDien Ha The
 
Brochure_26-80S-ANSI _SG104309BEN_B04-0914
Brochure_26-80S-ANSI _SG104309BEN_B04-0914Brochure_26-80S-ANSI _SG104309BEN_B04-0914
Brochure_26-80S-ANSI _SG104309BEN_B04-0914Patrick Volluz
 
Stahl 6039 Series Tubular Light Fittings – ATEX Zone 1 Zone 2 Hazardous Area ...
Stahl 6039 Series Tubular Light Fittings – ATEX Zone 1 Zone 2 Hazardous Area ...Stahl 6039 Series Tubular Light Fittings – ATEX Zone 1 Zone 2 Hazardous Area ...
Stahl 6039 Series Tubular Light Fittings – ATEX Zone 1 Zone 2 Hazardous Area ...Thorne & Derrick International
 
Stahl 6039 Series Tubular Light Fittings ATEX Zone 1 Zone 2 Hazardous Area L...
Stahl 6039 Series Tubular Light Fittings  ATEX Zone 1 Zone 2 Hazardous Area L...Stahl 6039 Series Tubular Light Fittings  ATEX Zone 1 Zone 2 Hazardous Area L...
Stahl 6039 Series Tubular Light Fittings ATEX Zone 1 Zone 2 Hazardous Area L...Thorne & Derrick International
 
Stahl Lighting EXLUX 6001 Light Fitting For Fluorescent Lamps – ATEX Zone 1 Z...
Stahl Lighting EXLUX 6001 Light Fitting For Fluorescent Lamps – ATEX Zone 1 Z...Stahl Lighting EXLUX 6001 Light Fitting For Fluorescent Lamps – ATEX Zone 1 Z...
Stahl Lighting EXLUX 6001 Light Fitting For Fluorescent Lamps – ATEX Zone 1 Z...Thorne & Derrick International
 

Similar to Stahl 8220 Star Reversing Starter Motor Starters - ATEX Zone 1 Zone 2 Hazardous Area (20)

Stahl 8264 CUBEx Reversing Starter Motor Starters – ATEX Zone 1 Zone 2 Hazard...
Stahl 8264 CUBEx Reversing Starter Motor Starters – ATEX Zone 1 Zone 2 Hazard...Stahl 8264 CUBEx Reversing Starter Motor Starters – ATEX Zone 1 Zone 2 Hazard...
Stahl 8264 CUBEx Reversing Starter Motor Starters – ATEX Zone 1 Zone 2 Hazard...
 
Stahl 8264 CUBEx Direct Online (DOL) Motor Starter – ATEX Zone 1 Zone 2 Hazar...
Stahl 8264 CUBEx Direct Online (DOL) Motor Starter – ATEX Zone 1 Zone 2 Hazar...Stahl 8264 CUBEx Direct Online (DOL) Motor Starter – ATEX Zone 1 Zone 2 Hazar...
Stahl 8264 CUBEx Direct Online (DOL) Motor Starter – ATEX Zone 1 Zone 2 Hazar...
 
Stahl 8264 CUBEx Star Delta Motor Starter – ATEX Zone 1 Zone 2 Hazardous Area
Stahl 8264 CUBEx Star Delta Motor Starter – ATEX Zone 1 Zone 2 Hazardous Area Stahl 8264 CUBEx Star Delta Motor Starter – ATEX Zone 1 Zone 2 Hazardous Area
Stahl 8264 CUBEx Star Delta Motor Starter – ATEX Zone 1 Zone 2 Hazardous Area
 
Switchtec Din Rail Terminal Brochure
Switchtec Din Rail Terminal BrochureSwitchtec Din Rail Terminal Brochure
Switchtec Din Rail Terminal Brochure
 
Catalog hitachi hitachi switch&breaders ctlg eng-dienhathe.org
Catalog hitachi hitachi switch&breaders ctlg eng-dienhathe.orgCatalog hitachi hitachi switch&breaders ctlg eng-dienhathe.org
Catalog hitachi hitachi switch&breaders ctlg eng-dienhathe.org
 
Renewable energy
Renewable energyRenewable energy
Renewable energy
 
Renewable energy
Renewable energyRenewable energy
Renewable energy
 
Stahl Series 8102 Junction Box
Stahl Series 8102 Junction BoxStahl Series 8102 Junction Box
Stahl Series 8102 Junction Box
 
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...
 
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...
 
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...
Stahl Junction Boxes 8102 Series – ATEX Zone 1 Zone 2 Hazardous Area Junction...
 
Stahl Lighting ECOLUX 6600 Light Fitting For Fluorescent Lamps – ATEX Zone 1 ...
Stahl Lighting ECOLUX 6600 Light Fitting For Fluorescent Lamps – ATEX Zone 1 ...Stahl Lighting ECOLUX 6600 Light Fitting For Fluorescent Lamps – ATEX Zone 1 ...
Stahl Lighting ECOLUX 6600 Light Fitting For Fluorescent Lamps – ATEX Zone 1 ...
 
Kraus & naimer emc-co mpliant conne-ction-kn_emc_gb_dienhathe.vn
Kraus & naimer emc-co mpliant conne-ction-kn_emc_gb_dienhathe.vnKraus & naimer emc-co mpliant conne-ction-kn_emc_gb_dienhathe.vn
Kraus & naimer emc-co mpliant conne-ction-kn_emc_gb_dienhathe.vn
 
Magnetic contactors and magnetic starters ms-t series dienhathe.org
Magnetic contactors and magnetic starters ms-t series dienhathe.orgMagnetic contactors and magnetic starters ms-t series dienhathe.org
Magnetic contactors and magnetic starters ms-t series dienhathe.org
 
Hvac valves and_actuators_catalogue
Hvac valves and_actuators_catalogueHvac valves and_actuators_catalogue
Hvac valves and_actuators_catalogue
 
Dienhathe.com semiconductor fuses
Dienhathe.com semiconductor fusesDienhathe.com semiconductor fuses
Dienhathe.com semiconductor fuses
 
Brochure_26-80S-ANSI _SG104309BEN_B04-0914
Brochure_26-80S-ANSI _SG104309BEN_B04-0914Brochure_26-80S-ANSI _SG104309BEN_B04-0914
Brochure_26-80S-ANSI _SG104309BEN_B04-0914
 
Stahl 6039 Series Tubular Light Fittings – ATEX Zone 1 Zone 2 Hazardous Area ...
Stahl 6039 Series Tubular Light Fittings – ATEX Zone 1 Zone 2 Hazardous Area ...Stahl 6039 Series Tubular Light Fittings – ATEX Zone 1 Zone 2 Hazardous Area ...
Stahl 6039 Series Tubular Light Fittings – ATEX Zone 1 Zone 2 Hazardous Area ...
 
Stahl 6039 Series Tubular Light Fittings ATEX Zone 1 Zone 2 Hazardous Area L...
Stahl 6039 Series Tubular Light Fittings  ATEX Zone 1 Zone 2 Hazardous Area L...Stahl 6039 Series Tubular Light Fittings  ATEX Zone 1 Zone 2 Hazardous Area L...
Stahl 6039 Series Tubular Light Fittings ATEX Zone 1 Zone 2 Hazardous Area L...
 
Stahl Lighting EXLUX 6001 Light Fitting For Fluorescent Lamps – ATEX Zone 1 Z...
Stahl Lighting EXLUX 6001 Light Fitting For Fluorescent Lamps – ATEX Zone 1 Z...Stahl Lighting EXLUX 6001 Light Fitting For Fluorescent Lamps – ATEX Zone 1 Z...
Stahl Lighting EXLUX 6001 Light Fitting For Fluorescent Lamps – ATEX Zone 1 Z...
 

More from Thorne & Derrick International

Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Thorne & Derrick International
 
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptTHORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptThorne & Derrick International
 
The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018Thorne & Derrick International
 
3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick InternationalThorne & Derrick International
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-AThorne & Derrick International
 
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...Thorne & Derrick International
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Thorne & Derrick International
 
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RowePepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RoweThorne & Derrick International
 
Ultrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandUltrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandThorne & Derrick International
 
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DSIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DThorne & Derrick International
 
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...Thorne & Derrick International
 
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetFiloform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetThorne & Derrick International
 

More from Thorne & Derrick International (20)

Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...
 
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptTHORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
 
The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018
 
3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International
 
CATU Electrical Safety Catalogue
CATU Electrical Safety CatalogueCATU Electrical Safety Catalogue
CATU Electrical Safety Catalogue
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
 
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
 
Roxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional DrawingRoxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional Drawing
 
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RowePepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
 
T&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive AtmospheresT&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive Atmospheres
 
Ultrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandUltrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification Demand
 
Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016
 
Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016
 
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DSIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
 
Ripley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation ToolsRipley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation Tools
 
RIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas DetectorRIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas Detector
 
Itron Fact Sheet
Itron Fact SheetItron Fact Sheet
Itron Fact Sheet
 
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
 
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetFiloform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
 

Recently uploaded

Snow Chain-Integrated Tire for a Safe Drive on Winter Roads
Snow Chain-Integrated Tire for a Safe Drive on Winter RoadsSnow Chain-Integrated Tire for a Safe Drive on Winter Roads
Snow Chain-Integrated Tire for a Safe Drive on Winter RoadsHyundai Motor Group
 
How to Remove Document Management Hurdles with X-Docs?
How to Remove Document Management Hurdles with X-Docs?How to Remove Document Management Hurdles with X-Docs?
How to Remove Document Management Hurdles with X-Docs?XfilesPro
 
SIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge GraphSIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge GraphNeo4j
 
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking MenDelhi Call girls
 
Artificial intelligence in the post-deep learning era
Artificial intelligence in the post-deep learning eraArtificial intelligence in the post-deep learning era
Artificial intelligence in the post-deep learning eraDeakin University
 
My Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationMy Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationRidwan Fadjar
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountPuma Security, LLC
 
Beyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
Beyond Boundaries: Leveraging No-Code Solutions for Industry InnovationBeyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
Beyond Boundaries: Leveraging No-Code Solutions for Industry InnovationSafe Software
 
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j
 
Pigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food ManufacturingPigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food ManufacturingPigging Solutions
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024Scott Keck-Warren
 
Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitecturePixlogix Infotech
 
Kotlin Multiplatform & Compose Multiplatform - Starter kit for pragmatics
Kotlin Multiplatform & Compose Multiplatform - Starter kit for pragmaticsKotlin Multiplatform & Compose Multiplatform - Starter kit for pragmatics
Kotlin Multiplatform & Compose Multiplatform - Starter kit for pragmaticscarlostorres15106
 
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 3652toLead Limited
 
Unblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesUnblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesSinan KOZAK
 
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure serviceWhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure servicePooja Nehwal
 
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024BookNet Canada
 
Pigging Solutions Piggable Sweeping Elbows
Pigging Solutions Piggable Sweeping ElbowsPigging Solutions Piggable Sweeping Elbows
Pigging Solutions Piggable Sweeping ElbowsPigging Solutions
 
Hyderabad Call Girls Khairatabad ✨ 7001305949 ✨ Cheap Price Your Budget
Hyderabad Call Girls Khairatabad ✨ 7001305949 ✨ Cheap Price Your BudgetHyderabad Call Girls Khairatabad ✨ 7001305949 ✨ Cheap Price Your Budget
Hyderabad Call Girls Khairatabad ✨ 7001305949 ✨ Cheap Price Your BudgetEnjoy Anytime
 
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptxMaking_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptxnull - The Open Security Community
 

Recently uploaded (20)

Snow Chain-Integrated Tire for a Safe Drive on Winter Roads
Snow Chain-Integrated Tire for a Safe Drive on Winter RoadsSnow Chain-Integrated Tire for a Safe Drive on Winter Roads
Snow Chain-Integrated Tire for a Safe Drive on Winter Roads
 
How to Remove Document Management Hurdles with X-Docs?
How to Remove Document Management Hurdles with X-Docs?How to Remove Document Management Hurdles with X-Docs?
How to Remove Document Management Hurdles with X-Docs?
 
SIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge GraphSIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge Graph
 
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
 
Artificial intelligence in the post-deep learning era
Artificial intelligence in the post-deep learning eraArtificial intelligence in the post-deep learning era
Artificial intelligence in the post-deep learning era
 
My Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationMy Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 Presentation
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path Mount
 
Beyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
Beyond Boundaries: Leveraging No-Code Solutions for Industry InnovationBeyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
Beyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
 
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
 
Pigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food ManufacturingPigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food Manufacturing
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024
 
Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC Architecture
 
Kotlin Multiplatform & Compose Multiplatform - Starter kit for pragmatics
Kotlin Multiplatform & Compose Multiplatform - Starter kit for pragmaticsKotlin Multiplatform & Compose Multiplatform - Starter kit for pragmatics
Kotlin Multiplatform & Compose Multiplatform - Starter kit for pragmatics
 
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
 
Unblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesUnblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen Frames
 
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure serviceWhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
 
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
 
Pigging Solutions Piggable Sweeping Elbows
Pigging Solutions Piggable Sweeping ElbowsPigging Solutions Piggable Sweeping Elbows
Pigging Solutions Piggable Sweeping Elbows
 
Hyderabad Call Girls Khairatabad ✨ 7001305949 ✨ Cheap Price Your Budget
Hyderabad Call Girls Khairatabad ✨ 7001305949 ✨ Cheap Price Your BudgetHyderabad Call Girls Khairatabad ✨ 7001305949 ✨ Cheap Price Your Budget
Hyderabad Call Girls Khairatabad ✨ 7001305949 ✨ Cheap Price Your Budget
 
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptxMaking_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
 

Stahl 8220 Star Reversing Starter Motor Starters - ATEX Zone 1 Zone 2 Hazardous Area

  • 1. Standard Motor Starters Series 8220 E7 E7 E7 E7 E7 www.stahl.de Load Disconnect Switches and Motor Starters E7/1 2014-07-02·EK00·III·en E7 E7 E7 E7 E7 E7 E7 E7 E7 Series 8220 E7 10102E00 WebCode 8220A > Enclosure with type of protection Ex d and terminal compartment enclosure with Ex e > Available standard motor controllers – Direct-on-line motor starters DOL – Star-delta starter combinations YD – Reversing starter combinations > Advantage – short delivery times The standard motor starters are fitted into enclosures with type of protection "flameproof enclosure". The standard starters are supplied without main switch, main fuses and without control and monitoring devices. These parts can be fitted to order. ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x x x
  • 2. Standard Motor Starters, Direct On-Line Motor Starters DOL Series 8220 Explosion Protection Global (IECEx) Gas IECEx PTB 06.0069 Ex de [ia/ib] IIC T6, T5, T4 Dust IECEx PTB 06.0069 Ex tD A21 IP6X T80°C, T95°C, T130°C Europe (ATEX) Gas and dust PTB 02 ATEX 1109 E II 2 G Ex de [ia/ib] IIC T6, T5, T4 E II 2 D Ex tD A21 IP66 T80°C, T95°C, T130°C Certifications and certificates Certificates IECEx, ATEX, Kazakhstan (TR), Korea (KCs), Russia (TR), Belarus (TR) Technical Data Electrical data Rated voltage 400 V AC Control voltage 230 V AC Circuit diagram 09805E00 Ambient conditions Ambient temperature -20 ... +40 °C Mechanical data Degree of protection IP55 (to order IP65) Enclosure material Sheet steel, cover: die-cast alloy / stainless steel Colour Enclosure: grey, RAL 7032, cover: dark grey, RAL 7022 Note Note Description: Single contactor for connecting and disconnecting the motor circuits and ohmic consumers. With thermal overcurrent release, version with control transformer acc. to EN 60204. Specify on order if the nominal voltage has a different value than 400 V because the transformer must then be selected appropriately. Direct On-Line Motor Starters DOL Selection Table Switching capacity 400 V AC-3 Ex d enclosure Terminals Cable entries bottom Order number 5.5 kW 8220/112 4 x 6 mm2 3 x 4 mm2 2 x M32 2 x M25 8220/5-SM-ES5,5kW400V-T 7.5 kW 8220/112 4 x 10 mm2 3 x 6 mm2 2 x M32 2 x M25 8220/5-SM-ES7,5kW400V-T 11 kW 8220/112 4 x 10 mm2 3 x 6 mm2 2 x M32 2 x M25 8220/5-SM-ES11kW400V-T 15 kW 8220/112 4 x 16 mm2 3 x 6 mm2 2 x M32 2 x M25 8220/5-SM-ES15kW400V-T 18.5 kW 8220/112 4 x 16 mm2 3 x 10 mm2 2 x M32 2 x M25 8220/5-SM-ES18,5kW400V-T 22 kW 8220/112 4 x 35 mm2 3 x 10 mm2 1 x M40 1 x M32 2 x M25 8220/5-SM-ES22kW400V-T 30 kW 8220/122 4 x 35 mm2 3 x 16 mm2 1 x M40 1 x M32 2 x M25 8220/5-SM-ES30kW400V-T 37 kW 8220/122 4 x 35 mm2 3 x 16 mm2 1 x M40 1 x M32 2 x M25 8220/5-SM-ES37kW400V-T 45 kW 8220/122 4 x 50 mm2 3 x 35 mm2 1 x M50 1 x M40 2 x M25 8220/5-SM-ES45kW400V-T 55 kW 8220/122 4 x 50 mm2 3 x 35 mm2 1 x M50 1 x M40 2 x M25 8220/5-SM-ES55kW400V-T 75 kW 8220/122 4 x 50 mm2 3 x 35 mm2 1 x M50 1 x M40 2 x M25 8220/5-SM-ES75kW400V-T E7/2 Load Disconnect Switches and Motor Starters 2014-07-02·EK00·III·en
  • 3. Standard Motor Starters, Star-Delta Contactor Starters YD Series 8220 E7 E7 E7 E7 E7 E7 E7 E7 E7 E7 E7 E7 E7 E7 Explosion Protection Global (IECEx) Gas IECEx PTB 06.0069 Ex de [ia/ib] IIC T6, T5, T4 Dust IECEx PTB 06.0069 Ex tD A21 IP6X T80°C, T95°C, T130°C Europe (ATEX) Gas and dust PTB 02 ATEX 1109 E II 2 G Ex de [ia/ib] IIC T6, T5, T4 E II 2 D Ex tD A21 IP66 T80°C, T95°C, T130°C Certifications and certificates Certificates IECEx, ATEX, Kazakhstan (TR), Korea (KCs), Russia (TR), Belarus (TR) Technical Data Electrical data Rated voltage 400 V AC Control voltage 230 V AC Circuit diagram 09806E00 Ambient conditions Ambient temperature -20 ... +40 °C Mechanical data Degree of protection IP55 (to order IP65) Enclosure material Sheet steel, cover: die-cast alloy / stainless steel Colour Enclosure: grey, RAL 7032, cover: dark grey, RAL 7022 Note Note Description: Contactor combination for connecting and disconnecting the motor circuits and ohmic consumers. With thermal overcurrent release, version with control transformer acc. to EN 60204. Specify on order if the nominal voltage has a different value than 400 V because the transformer must then be selected appropriately. Star-Delta Starter Combinations YD Selection Table Switching capacity 400 V AC-3 Ex d enclosure Terminals Cable entries bottom Order number 11 kW 8220/122 4 x 6 mm2 6 x 4 mm2 3 x M32 2 x M25 8220/5-SL-SS11kW400V-T 15 kW 8220/122 4 x 6 mm2 6 x 4 mm2 3 x M32 2 x M25 8220/5-SL-SS15kW400V-T 18.5 kW 8220/122 4 x 6 mm2 6 x 4 mm2 3 x M32 2 x M25 8220/5-SL-SS18,5kW400V-T 22 kW 8220/122 4 x 10 mm2 6 x 6 mm2 3 x M32 2 x M25 8220/5-SL-SS22kW400V-T 30 kW 8220/172 4 x 16 mm2 6 x 6 mm2 3 x M40 2 x M25 8220/5-SL-SS30kW400V-T 37 kW 8220/172 4 x 35 mm2 6 x 10 mm2 3 x M40 2 x M25 8220/5-SL-SS37kW400V-T 45 kW 8220/132 4 x 35 mm2 6 x 16 mm2 1 x M50 2 x M40 2 x M25 8220/5-SL-SS45kW400V-T 55 kW 8220/132 4 x 50 mm2 6 x 35 mm2 1 x M50 2 x M40 2 x M25 8220/5-SL-SS55kW400V-T 75 kW 8220/132 4 x 50 mm2 6 x 35 mm2 1 x M50 2 x M40 2 x M25 8220/5-SL-SS75kW400V-T 90 kW 8220/133 4 x 95 mm2 6 x 50 mm2 1 x M63 2 x M40 2 x M25 8220/5-SL-SS90kW400V-T 110 kW 8220/133 4 x 150 mm2 6 x 95 mm2 1 x M63 2 x M50 2 x M25 8220/5-SL-SS110kW400V-T 132 kW 8220/133 4 x 150 mm2 6 x 95 mm2 1 x M63 2 x M50 2 x M25 8220/5-SL-SS132kW400V-T 160 kW 8220/196 4 x 240 mm2 6 x 150 mm2 3 x M63 2 x M25 8220/5-SL-SS160kW400V-T 200 kW 8220/196 4 x 240 mm2 6 x 150 mm2 3 x M63 2 x M25 8220/5-SL-SS200kW400V-T 2014-07-02·EK00·III·en Load Disconnect Switches and Motor Starters E7/3
  • 4. Standard Motor Starters, Reversing Starter Combinations Series 8220 Explosion Protection Global (IECEx) Gas IECEx PTB 06.0069 Ex de [ia/ib] IIC T6, T5, T4 Dust IECEx PTB 06.0069 Ex tD A21 IP6X T80°C, T95°C, T130°C Europe (ATEX) Gas and dust PTB 02 ATEX 1109 E II 2 G Ex de [ia/ib] IIC T6, T5, T4 E II 2 D Ex tD A21 IP66 T80°C, T95°C, T130°C Certifications and certificates Certificates IECEx, ATEX, Kazakhstan (TR), Korea (KCs), Russia (TR), Belarus (TR) Technical Data Electrical data Rated voltage 400 V AC Control voltage 230 V AC Circuit diagram 10043E00 Ambient conditions Ambient temperature -20 ... +40 °C Mechanical data Degree of protection IP55 (to order IP65) Enclosure material Sheet steel, cover: die-cast alloy / stainless steel Colour Enclosure: grey, RAL 7032, cover: dark grey, RAL 7022 Note Note Description: Contactor combination for changing the phase sequence of the motor circuits. With thermal overcurrent release, version with control transformer acc. to EN 60204. Specify on order if the nominal voltage has a different value than 400 V because the transformer must then be selected appropriately. Reversing Starter Combinations Selection Table Switching capacity 400 V AC-3 Ex d enclosure Terminals Cable entries bottom Order number 5.5 kW 8220/122 4 x 6 mm2 3 x 4 mm2 2 x M32 2 x M25 8220/5-SL-WS5,5kW400V-T 7.5 kW 8220/122 4 x 6 mm2 3 x 4 mm2 2 x M32 2 x M25 8220/5-SL-WS7,5kW400V-T 11 kW 8220/122 4 x 10 mm2 3 x 6 mm2 2 x M32 2 x M25 8220/5-SL-WS11kW400V-T 15 kW 8220/122 4 x 16 mm2 3 x 6 mm2 2 x M32 2 x M25 8220/5-SL-WS15kW400V-T 18.5 kW 8220/122 4 x 16 mm2 3 x 10 mm2 2 x M32 2 x M25 8220/5-SL-WS18,5kW400V-T 22 kW 8220/122 4 x 35 mm2 3 x 16 mm2 1 x M40 1 x M32 2 x M25 8220/5-SL-WS22kW400V-T 30 kW 8220/122 4 x 35 mm2 3 x 16 mm2 1 x M40 1 x M32 2 x M25 8220/5-SL-WS30kW400V-T 37 kW 8220/122 4 x 50 mm2 3 x 35 mm2 1 x M40 1 x M32 2 x M25 8220/5-SL-WS37kW400V-T 45 kW 8220/122 4 x 95 mm2 3 x 35 mm2 1 x M50 1 x M40 2 x M25 8220/5-SL-WS45kW400V-T 55 kW 8220/133 4 x 95 mm2 3 x 50 mm2 1 x M50 1 x M40 2 x M25 8220/5-SL-WS55kW400V-T 75 kW 8220/133 4 x 95 mm2 3 x 95 mm2 1 x M63 1 x M50 2 x M25 8220/5-SL-WS75kW400V-T E7/4 Load Disconnect Switches and Motor Starters 2014-07-02·EK00·III·en
  • 5. Standard Motor Starters Series 8220 E7 E7 E7 E7 E7 E7 E7 E7 E7 E7 E7 E7 E7 E7 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 04470E00 8220/112 04471E00 8220/122 04472E00 8220/172 04474E00 8220/132 04475E00 8220/133 04477E00 8220/196 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. 2014-07-02·EK00·III·en Load Disconnect Switches and Motor Starters E7/5