  1. 1. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment PAPD Anelli premiarmatura ottone nichelato PAPD Feam Catalogue 01 - 131 Ex Cable Glands CABLE GLANDS FOR ARMOURED CABLES On Request Accessories: • Locknuts, Gaskets, PVC Shrouds, Earthing Tags, Sealing (See ACCESSORI bulletin) Mechanical characteristics Body / cap OT-58 marine brass (ON) - AISI-316L stainless steel (IX) - *anticorodal aluminium (AL) Finishes full nickel plating threatment (brass material only) Rubber rings EDPM rubber- 50-60 shore hardness O-ring silicon rubber - 60 shore hardness Skid washer nylon 6 Chamber for sealing OT-58 marine brass ("R" version only) Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D APPLICATION • FOR STEEL WIRE ARMOURED CABLES (SWA) FOR STEEL TAPE ARMOURED CABLES AND FOR LEAD INNER SHEATH CABLES • DOUBLE COMPRESSION TYPE FOR INDOOR AND OUTDOOR USE • PROVIDED ARMOUR CLAMPING USING CLAMPING ARRANGEMENTS SUITABLE FOR ALL ARMOUR WIRE/BRAID TYPES • INTERNAL LEAD DEVICE FOR ELECTRICAL BOND OF CABLE LEAD INNER SHEATH • DOUBLE COMPRESSION - UNDER ARMOUR AND OVERALL OF ARMOUR CABLE ( INNER AND OUTER SEALING ) • SEALING WITH PROPER RESIN INTO "CHAMBER OF SEALING" ( ON BARRIER TYPE VERSION "R" ONLY ) *ON REQUEST ONLY. PLEASE CONTACT OUR SALES OFFICE FOR MIN QUANTITY TO ORDER CABLE GLANDS ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex d II C II 2 G Ex e II II 2 D Ex tD A21 Ex d IIC / Ex e II DIP A21 Ex d IIC / Ex e II DIP A21 AMBIENT TEMPERATURE -40°C ÷ +90°C (1) -50°C ÷ +180°C (2) -40°C ÷ +90°C (1) -60°C ÷ +180°C (2) -40°C ÷ +90°C (1) -60°C ÷ +180°C (2) PROTECTION DEGREE IP66 IP66 IP66 CERTIFICATE REF. INERIS 07 ATEX 0001X POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-7; EN 61241-0; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 (1) EDPM-60 INTERNAL RUBBER RINGS - (2) SILICON-60 INTERNAL RUBBER RINGS
  2. 2. YOUR PARTNER FOR SAFETY Since 1961 PAPD A C D B 1 2 3 5 64 7 8 9 111012 PAPD# 01 M ON PAPD# 03 N IX PAPD-R# 04 N AL 132 - Feam Catalogue 01 Ex Cable Glands PAPD Cable gland selection table CODE ENTRY THREAD SIZE (C) INNER SHEATH DIA. (A) OUTER SHEATH DIA. (B) HEXAGON (D) MATERIAL (1) METRIC (2) NPT (2) UNI ISO 228 (2) min [mm] max [mm] min [mm] max [mm] [mm] (3) PAPD# PAPD-R# 01 ISO-M20 1/2"NPT 1/2" 4,5 11,0 10,0 19,0 32,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PAPD# PAPD-R# 02 ISO-M25 3/4”NPT 3/4” 8,5 16,0 15,0 24,0 36,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PAPD# PAPD-R# 03 ISO-M32 1”NPT 1” 13,0 22,0 20,0 31,0 45,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PAPD# PAPD-R# 04 ISO-M40 1 1/4”NPT 1 1/4” 19,0 28,0 25,0 37,0 53,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PAPD# PAPD-R# 05 ISO-M50 1 1/2”NPT 1 1/2” 22,0 34,0 31,0 43,0 61,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PAPD# PAPD-R# 06 ISO-M63 2”NPT 2” 34,0 43,0 42,0 53,0 71,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PAPD# PAPD-R# 07 ISO-M75 2 1/2”NPT 2 1/2” 43,0 52,0 52,0 64,0 84,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PAPD# PAPD-R# 08 ISO-M90 3”NPT 3” 52,0 65,0 65,0 78,0 101,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL CABLE GLAND ORDERING EXAMPLES LEGEND = PAPD#01MON (NON-BARRIER CABLE GLAND NICKEL PLATED BRASS ISO-M20 THR.) = PAPD#03NIX (NON-BARRIER CABLE GLAND STAINLESS STEEL 1”NPT THR.) = PAPD-R#04NAL (BARRIER CABLE GLAND NICKEL PLATED BRASS 1 1/4”NPT THR.) (1) CABLE GLAND TYPE/MODEL PAPD# = NON-BARRIER CABLE GLAND - PAPD-R# = BARRIER CABLE GLAND (2) THREADING M = ISO METRIC pitch 1,5mm - N = NPT (ANSI/ASME B1.20.1) - G = UNI ISO-228 (3) CABLE GLAND MATERIAL ON = NICKEL PLATED MARINE BRASS - IN = AISI-316L STAINLESS STEEL - AL = ANTICORODAL ALUMINIUM REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. PAPD Dimensional 1. skid washer 2. outer seal 3. cable armour rings 4. cable armour rings 5. inner seal 6. *chamber for sealing (“R” version only) 7. armoured cable 8. cap 9. middle body 10. body 11. O-ring 12. LEAD RING SIZE N N N N N N N N G G G G G G G G M M M M M M M M * Chamber will be filled with sealing when cable gland is completely assembled.
  3. 3. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment PAP Anelli premiarmatura ottone nichelato PAP Feam Catalogue 01 - 133 Ex Cable Glands CABLE GLANDS FOR ARMOURED CABLES On Request Accessories: • Locknuts, Gaskets, PVC Shrouds, Earthing Tags, Sealing (See ACCESSORI bulletin) Mechanical characteristics Body / cap OT-58 marine brass (ON) - AISI-316L stainless steel (IX)- *anticorodal aluminium (AL) Finishes full nickel plating threatment (brass material only) Rubber rings EDPM rubber- 50-60 shore hardness - Silicon rubber - 60 shore hardness O-ring silicon rubber - 60 shore hardness Skid washer nylon 6 Chamber for sealing OT-58 marine brass ("R" version only) Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D APPLICATION • FOR STEEL WIRE ARMOURED CABLES (SWA) FOR STEEL TAPE ARMOURED CABLES • DOUBLE COMPRESSION TYPE FOR INDOOR AND OUTDOOR USE • PROVIDED ARMOUR CLAMPING USING CLAMPING ARRANGEMENTS SUITABLE FOR ALL ARMOUR WIRE/BRAID TYPES • DOUBLE COMPRESSION - UNDER ARMOUR AND OVERALL OF ARMOUR CABLE ( INNER AND OUTER SEALING ) • SEALING WITH PROPER RESIN INTO "CHAMBER OF SEALING" ( ON BARRIER TYPE VERSION "R" ONLY ) *ON REQUEST ONLY. PLEASE CONTACT OUR SALES OFFICE FOR MIN QUANTITY TO ORDER (1) EDPM-60 INTERNAL RUBBER RINGS - (2) SILICON-60 INTERNAL RUBBER RINGS CABLE GLANDS ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex d II C II 2 G Ex e II II 2 D Ex tD A21 Ex d IIC / Ex e II DIP A21 Ex d IIC / Ex e II DIP A21 AMBIENT TEMPERATURE -40°C ÷ +90°C (1) -50°C ÷ +180°C (2) -40°C ÷ +90°C (1) -60°C ÷ +180°C (2) -40°C ÷ +90°C (1) -60°C ÷ +180°C (2) PROTECTION DEGREE IP66 IP66 IP66 CERTIFICATE REF. INERIS 07 ATEX 0001X POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-7; EN 61241-0; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002
  4. 4. YOUR PARTNER FOR SAFETY Since 1961 PAP A C D B 1 2 3 5 64 7 8 9 1110 PAP# 01 M ON PAP# 03 N IX PAP-R# 04 N AL SIZE 134 - Feam Catalogue 01 CODE ENTRY THREAD SIZE (C) INNER SHEATH DIA. (A) OUTER SHEATH DIA. (B) HEXAGON (D) MATERIAL (1) METRIC (2) NPT (2) UNI ISO 228 (2) min [mm] max [mm] min [mm] max [mm] [mm] (3) PAP# PAP-R# 00 ISO-M20 1/2”NPT 1/2” 4,0 10,0 10,0 15,0 26,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PAP# PAP-R# 01 ISO-M20 1/2"NPT 1/2" 5,5 13,0 15,0 19,0 32,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PAP# PAP-R# 02 ISO-M25 3/4”NPT 3/4” 10,5 18,0 15,0 24,0 36,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PAP# PAP-R# 03 ISO-M32 1”NPT 1” 15,0 24,0 21,0 31,0 45,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PAP# PAP-R# 04 ISO-M40 1 1/4”NPT 1 1/4” 21,0 30,0 24,0 37,0 53,0 NICKEL PL.BRASS STAINLESS STEEL ALLUMINIUM ON IX AL PAP# PAP-R# 05 ISO-M50 1 1/2”NPT 1 1/2” 24,0 36,0 36,0 43,0 61,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PAP# PAP-R# 06 ISO-M63 2”NPT 2” 36,0 45,0 45,0 53,0 71,0 NICKEL PL.BRASS STAINLESS STEEL ALLUMINIUM ON IX AL PAP# PAP-R# 07 ISO-M75 2 1/2”NPT 2 1/2” 45,0 54,0 52,0 64,0 84,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PAP# PAP-R# 08 ISO-M90 3”NPT 3” 52,0 65,0 65,0 78,0 101,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL Ex Cable Glands PAP Cable gland selection table CABLE GLAND ORDERING EXAMPLES LEGEND (1) CABLE GLAND TYPE/MODEL PAP# = NON-BARRIER CABLE GLAND - PAP-R# = BARRIER CABLE GLAND (2) THREADING M = ISO METRIC pitch 1,5mm - N = NPT (ANSI/ASME B1.20.1) - G = UNI ISO-228 (3) CABLE GLAND MATERIAL ON = NICKEL PLATED MARINE BRASS - IN = AISI-316L STAINLESS STEEL - AL = ANTICORODAL ALUMINIUM REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. PAP Dimensional 1. skid washer 2. outer seal 3. cable armour rings 4. cable armour rings 5. inner seal 6. *chamber for sealing (“R” version only) 7. armoured cable 8. cap 9. middle body 10. body 11. O-ring = PAP#01MON (NON-BARRIER CABLE GLAND NICKEL PLATED BRASS ISO-M20 THR.) = PAP#03NIX (NON-BARRIER CABLE GLAND STAINLESS STEEL 1”NPT THR.) = PAP-R#04NAL (BARRIER CABLE GLAND NICKEL PLATED BRASS 1 1/4”NPT THR.) M M M M M M M M M N N N N N N N N N G G G G G G G G G * Chamber will be filled with sealing when cable gland is completely assembled.
  5. 5. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment PA PA Feam Catalogue 01 - 135 Ex Cable Glands CABLE GLANDS FOR ARMOURED CABLES On Request Accessories: •Locknuts, Gaskets, PVC Shrouds, Earthing Tags, Sealing (See ACCESSORI bulletin) Mechanical characteristics Body / cap OT-58 marine brass (ON) - AISI-316L stainless steel (IX) - *anticorodal aluminium (AL) Finishes full nickel plating threatment (brass material only) Rubber rings EDPM rubber- 50-60 shore hardness - Silicon rubber - 60 shore hardness O-ring silicon rubber - 60 shore hardness Skid washer nylon 6 Chamber for sealing OT-58 marine brass ("R" version only) Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D APPLICATION • FOR STEEL WIRE ARMOURED CABLES (SWA) FOR STEEL TAPE ARMOURED CABLES • DOUBLE COMPRESSION TYPE FOR INDOOR AND OUTDOOR USE • PROVIDED ARMOUR CLAMPING USING CLAMPING ARRANGEMENTS SUITABLE FOR ALL ARMOUR WIRE/BRAID TYPES • DOUBLE COMPRESSION - UNDER ARMOUR AND OVERALL OF ARMOUR CABLE ( INNER AND OUTER SEALING ) • SEALING WITH PROPER RESIN INTO "CHAMBER OF SEALING" ( ON BARRIER TYPE VERSION "R" ONLY ) *ON REQUEST ONLY. PLEASE CONTACT OUR SALES OFFICE FOR MIN QUANTITY TO ORDER CABLE GLANDS ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex d II C II 2 G Ex e II II 2 D Ex tD A21 Ex d IIC / Ex e II DIP A21 Ex d IIC / Ex e II DIP A21 AMBIENT TEMPERATURE -40°C ÷ +90°C (1) -50°C ÷ +180°C (2) -40°C ÷ +90°C (1) -60°C ÷ +180°C (2) -40°C ÷ +90°C (1) -60°C ÷ +180°C (2) PROTECTION DEGREE IP66 IP66 IP66 CERTIFICATE REF. INERIS 07 ATEX 0001X POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-7; EN 61241-0; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 (1) EDPM-60 INTERNAL RUBBER RINGS - (2) SILICON-60 INTERNAL RUBBER RINGS
  6. 6. YOUR PARTNER FOR SAFETY Since 1961 PA A C B D 1 2 3 4 5 6 7 PA# 01 M ON PA# 03 N IX PA-R# 04 N AL 136 - Feam Catalogue 01 CODE ENTRY THREAD SIZE (C) INNER SHEATH DIA. (A) OUTER SHEATH DIA. (B) HEXAGON (D) MATERIAL (1) METRIC (2) NPT (2) UNI ISO 228 (2) min [mm] max [mm] max [mm] [mm] (3) PA# PA-R# 00 ISO-M20 1/2"NPT 1/2" 4,0 10,0 16,0 26,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PA# PA-R# 01 ISO-M20 1/2"NPT 1/2" 5,5 13,0 20,0 32,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PA# PA-R# 02 ISO-M25 3/4"NPT 3/4" 10,5 18,0 25,0 36,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PA# PA-R# 03 ISO-M32 1"NPT 1" 15,0 24,0 32,0 45,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PA# PA-R# 04 ISO-M40 1 1/4"NPT 1 1/4" 21,0 30,0 38,0 53,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PA# PA-R# 05 ISO-M50 1 1/2"NPT 1 1/2" 24,0 36,0 44,0 61,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PA# PA-R# 06 ISO-M63 2"NPT 2" 36,0 45,0 54,0 71,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PA# PA-R# 07 ISO-M75 2 1/2"NPT 2 1/2" 45,0 54,0 65,0 84,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PA# PA-R# 08 ISO-M90 3"NPT 3" 52,0 65,0 79,0 101,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL Ex Cable Glands PA Cable gland selection table CABLE GLAND ORDERING EXAMPLES LEGEND = PA#01MON (NON-BARRIER CABLE GLAND NICKEL PLATED BRASS ISO-M20 THR.) = PA#03NIX (NON-BARRIER CABLE GLAND STAINLESS STEEL 1”NPT THR.) = PA-R#04NAL (BARRIER CABLE GLAND NICKEL PLATED BRASS 1 1/4”NPT THR.) (1) CABLE GLAND TYPE/MODEL PA# = NON-BARRIER CABLE GLAND - PA-R# = BARRIER CABLE GLAND (2) THREADING M = ISO METRIC pitch 1,5mm - N = NPT (ANSI/ASME B1.20.1) - G = UNI ISO-228 (3) CABLE GLAND MATERIAL ON = NICKEL PLATED MARINE BRASS - IN = AISI-316L STAINLESS STEEL - AL = ANTICORODAL ALUMINIUM REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. SIZE PA Dimensional 1. cable armour rings 2. inner seal 3. * chamber for sealing (“R” version only) 4. armoured cable 5. cap 6. body 7. O-RING M M M M M M M M M N N N N N N N N N G G G G G G G G G * Chamber will be filled with sealing when cable gland is completely assembled.
  7. 7. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment PNA PNA Feam Catalogue 01 - 137 Ex Cable Glands CABLE GLANDS FOR UNARMOURED CABLES On Request Accessories: • Locknuts, Gaskets, PVC Shrouds, Earthing Tags, Sealing (See ACCESSORI bulletin) Mechanical characteristics Body / cap OT-58 marine brass (ON) - AISI-316L stainless steel (IX) - *anticorodal aluminium (AL) Finishes full nickel plating threatment (brass material only) Rubber rings EDPM rubber- 50-60 shore hardness - Silicon rubber - 60 shore hardness O-ring silicon rubber - 60 shore hardness Skid washer nylon 6 Chamber for sealing OT-58 marine brass ("R" version only) Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D APPLICATION • FOR UNARMOURED CABLES ONLY • SINGLE COMPRESSION TYPE SUITABLE FOR INDOOR AND OUTDOOR USE • SINGLE COMPRESSION - ON CABLE (INNER SEALING) • SEALING WITH PROPER RESIN INTO “CHAMBER OF SEALING” (ON BARRIER TYPE VERSION “R” ONLY) *ON REQUEST ONLY. PLEASE CONTACT OUR SALES OFFICE FOR MIN QUANTITY TO ORDER CABLE GLANDS ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex d II C II 2 G Ex e II II 2 D Ex tD A21 Ex d IIC / Ex e II DIP A21 Ex d IIC / Ex e II DIP A21 AMBIENT TEMPERATURE -40°C ÷ +90°C (1) -50°C ÷ +180°C (2) -40°C ÷ +90°C (1) -60°C ÷ +180°C (2) -40°C ÷ +90°C (1) -60°C ÷ +180°C (2) PROTECTION DEGREE IP66 IP66 IP66 CERTIFICATE REF. INERIS 07 ATEX 0001X POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-7; EN 61241-0; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 (1) EDPM-60 INTERNAL RUBBER RINGS - (2) SILICON-60 INTERNAL RUBBER RINGS
  8. 8. YOUR PARTNER FOR SAFETY Since 1961 PNA A C B D 1 2 3 4 5 6 7 PNA# 01 M ON PNA# 03 N IX PNA-R# 04 N AL 138 - Feam Catalogue 01 CODE ENTRY THREAD SIZE (C) INNER SHEATH DIA. (A) OUTER SHEATH DIA. (B) HEXAGON (D) MATERIAL (1) METRIC (2) NPT (2) UNI ISO 228 (2) min [mm] max [mm] max [mm] [mm] (3) PNA# PNA-R# 00 ISO-M20 1/2"NPT 1/2" 4,0 10,0 16,0 26,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PNA# PNA-R# 01 ISO-M20 1/2"NPT 1/2" 5,5 13,0 20,0 32,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PNA# PNA-R# 02 ISO-M25 3/4"NPT 3/4" 10,5 18,0 25,0 36,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PNA# PNA-R# 03 ISO-M32 1"NPT 1" 15,0 24,0 32,0 45,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PNA# PNA-R# 04 ISO-M40 1 1/4"NPT 1 1/4" 21,0 30,0 38,0 53,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PNA# PNA-R# 05 ISO-M50 1 1/2"NPT 1 1/2" 24,0 36,0 44,0 61,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PNA# PNA-R# 06 ISO-M63 2"NPT 2" 36,0 45,0 54,0 71,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PNA# PNA-R# 07 ISO-M75 2 1/2"NPT 2 1/2" 45,0 54,0 65,0 84,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PNA# PNA-R# 08 ISO-M90 3"NPT 3" 52,0 65,0 79,0 101,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL M M M M M M M M M N N N N N N N N N G G G G G G G G G Ex Cable Glands PNA Cable gland selection table CABLE GLAND ORDERING EXAMPLES LEGEND = PNA#01MON (NON-BARRIER CABLE GLAND NICKEL PLATED BRASS ISO-M20 THR.) = PNA#03NIX (NON-BARRIER CABLE GLAND STAINLESS STEEL 1/2”NPT THR.) = PNA-r#04NON (BARRIER CABLE GLAND NICKEL PLATED BRASS 1 1/4”NPT THR.) (1) CABLE GLAND TYPE/MODEL PNA# = NON-BARRIER CABLE GLAND - PNA-R# = BARRIER CABLE GLAND (2) THREADING M = ISO METRIC pitch 1,5mm - N = NPT (ANSI/ASME B1.20.1) - G = UNI ISO-228 (3) CABLE GLAND MATERIAL ON = NICKEL PLATED MARINE BRASS - IN = AISI-316L STAINLESS STEEL - AL = ANTICORODAL ALUMINIUM REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. SIZE PNA Dimensional 1. rings for seal 2. inner seal 3. * chamber for sealing (“R” version only) 4. cable without armour 5. cap 6. body 7. O-RING * Chamber will be filled with sealing when cable gland is completely assembled.
  9. 9. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment PNAF PNAF Feam Catalogue 01 - 139 Ex Cable Glands CABLE GLANDS FOR UNARMOURED CABLES On Request Accessories: • Locknuts, Gaskets, PVC Shrouds, Earthing Tags, Sealing (See ACCESSORI bulletin) Mechanical characteristics Body / cap OT-58 marine brass (ON) - AISI-316L stainless steel (IX) - * anticorodal aluminium (AL) Finishes full nickel plating threatment (brass material only) Rubber rings EDPM rubber- 50-60 shore hardness - Silicon rubber - 60 shore hardness O-ring silicon rubber - 60 shore hardness Skid washer nylon 6 Chamber for sealing OT-58 marine brass ("R" version only) Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D APPLICATION • FOR UNARMOURED CABLES ONLY • SUITABLE FOR FLEXIBLE CONDUIT COUPLING CONNECTION BY THREADED CAP (UNI ISO 228) • SINGLE COMPRESSION TYPE SUITABLE FOR INDOOR AND OUTDOOR USE • SINGLE COMPRESSION - ON CABLE (INNER SEALING) • SEALING WITH PROPER RESIN INTO "CHAMBER OF SEALING" ( ON BARRIER TYPE VERSION "R" ONLY ) *ON REQUEST ONLY. PLEASE CONTACT OUR SALES OFFICE FOR MIN QUANTITY TO ORDER (1) EDPM-60 INTERNAL RUBBER RINGS - (2) SILICON-60 INTERNAL RUBBER RINGS CABLE GLANDS ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex d II C II 2 G Ex e II II 2 D Ex tD A21 Ex d IIC / Ex e II DIP A21 Ex d IIC / Ex e II DIP A21 AMBIENT TEMPERATURE -40°C ÷ +90°C (1) -50°C ÷ +180°C (2) -40°C ÷ +90°C (1) -60°C ÷ +180°C (2) -40°C ÷ +90°C (1) -60°C ÷ +180°C (2) PROTECTION DEGREE IP66 IP66 IP66 CERTIFICATE REF. INERIS 07 ATEX 0001X POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-7; EN 61241-0; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002
  10. 10. YOUR PARTNER FOR SAFETY Since 1961 PNAF C A B C1 D 1 2 3 4 5 6 7 PNAF# 01 M ON PNAF# 03 N IX PNAF-R# 04 N AL 140 - Feam Catalogue 01 Ex Cable Glands PNAF Cable gland selection table LEGEND (1) CABLE GLAND TYPE/MODEL PNAF# = NON-BARRIER CABLE GLAND - PNAF-R# = BARRIER CABLE GLAND (2) THREADING M = ISO METRIC pitch 1,5mm - N = NPT (ANSI/ASME B1.20.1 - G = UNI ISO-228 (3) CABLE GLAND MATERIAL ON = NICKEL PLATED MARINE BRASS - IN = AISI-316L STAINLESS STEEL - AL = ANTICORODAL ALUMINIUM (4) FEMALE THREAD UNI ISO-228 FEMALE THREAD SUITABLE FOR FLEXIBLE CONDUIT COUPLING REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. PNAF Dimensional 1. rings for seal 2. inner seal 3. * chamber for sealing (“R” version only) 4. cable without armour 5. threaded cap 6. body 7. O-RING * Chamber will be filled with sealing when cable gland is completely assembled. CODE ENTRY THREAD SIZE (C) INNER SHEATH DIA (A) OUTER SHEATH DIA. (B) FEM.THREAD (C1) EXAG. (D) MATERIAL (1) METRIC (2) NPT (2) UNI ISO 228 (2) min [mm] max [mm] min [mm] UNI ISO 228 (4) [mm] (3) PNAF# PNAF-R# 01 ISO-M20 1/2"NPT 1/2" 5,5 13,0 20,0 1/2" 32,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PNAF# PNAF-R# 02 ISO-M25 3/4"NPT 3/4" 10,5 18,0 25,0 3/4" 36,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PNAF# PNAF-R# 03 ISO-M32 1"NPT 1" 15,0 24,0 32,0 1" 45,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PNAF# PNAF-R# 04 ISO-M40 1 1/4"NPT 1 1/4" 21,0 30,0 38,0 1 1/4" 53,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PNAF# PNAF-R# 05 ISO-M50 1 1/2"NPT 1 1/2" 24,0 36,0 44,0 1 1/2" 61,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PNAF# PNAF-R# 06 ISO-M63 2"NPT 2" 36,0 45,0 54,0 2" 71,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PNAF# PNAF-R# 07 ISO-M75 2 1/2"NPT 2 1/2" 45,0 54,0 65,0 2 1/2" 84,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL PNAF# PNAF-R# 08 ISO-M90 3"NPT 3" 52,0 65,0 79,0 3" 101,0 NICKEL PL.BRASS STAINLESS STEEL ALUMINIUM ON IX AL CABLE GLAND ORDERING EXAMPLES = PNAF#01MON (NON-BARRIER CABLE GLAND NICKEL PLATED BRASS ISO-M20 THR.) = PNAF#03NIX (NON-BARRIER CABLE GLAND STAINLESS STEEL 1/2”NPT THR.) = PNAF-R#04NON (BARRIER CABLE GLAND NICKEL PLATED BRASS 1 1/4”NPT THR.) SIZE M M M M M M M M N N N N N N N N G G G G G G G G
  11. 11. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment DL-NW-PTD-ET DL-NW-PTD-ET DL NW PTD ET M Feam Catalogue 01 - 141 Ex Cable Glands CABLE GLANDS ACCESORIES Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D APPLICATIONS Mechanical characteristics LOCKNUTS Material nichel plated brass Finishes full nickel plating threatment (brass material only) LOCKNUTS Are preffered items used in securing cable glands to the gland plate especially to plastic junction boxes SHORUDS For all tipe of glands application where additional protection is required SILICONE SEALANT Is provided for submission of barrier cable glands type-R GASKETS Are used to mantain the ip rating across the interface between the equipment and relevant cable gland EARTH TAGS Are used to ensure earth continuity and grounding of cable armour SHORUDS Material PVC GASKETS Material nylon 6.0 EARTH TAGS Material stainless steel CABLE GLANDS ACCESSORIES ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex d II C II 2 G Ex e II II 2 D Ex tD A21 Ex d IIC / Ex e II DIP A21 Ex d IIC / Ex e II DIP A21 AMBIENT TEMPERATURE -50°C ÷ +180°C -50°C ÷ +180°C -50°C ÷ +180°C PROTECTION DEGREE IP66 IP66 IP66 CERTIFICATE REF. INERIS 07 ATEX 0001X POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-7; EN 61241-0; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 SILICON
  12. 12. YOUR PARTNER FOR SAFETY Since 1961 DL-NW-PTD-ET DL0 3/8" 3/8" M16 DL1 1/2" 1/2" M20 DL2 3/4" 3/4" M25 DL3 1" 1" M32 DL4 1-1/4" 1-1/4" M40 DL5 1-1/2" 1-1/2" M50 DL6 2" 2" M75 DL7 2-1/2" 2-1/2" M75 DL8 3" 3" M90 NW0 3/8" 3/8" M16 NW1 1/2" 1/2" M20 NW2 3/4" 3/4" M25 NW3 1" 1" M32 NW4 1-1/4" 1-1/4" M40 NW5 1-1/2" 1-1/2" M50 NW6 2" 2" M75 NW7 2-1/2" 2-1/2" M75 NW8 3" 3" M90 M20 20 C M25 25 C M32 32 C M40 40 C M50 50 C M63 63 C PTD0 3/8" 3/8" M16 PTD1 1/2" 1/2" M20 PTD2 3/4" 3/4" M25 PTD3 1" 1" M32 PTD4 1-1/4" 1-1/4" M40 PTD5 1-1/2" 1-1/2" M50 PTD6 2" 2" M75 PTD7 2-1/2" 2-1/2" M75 PTD8 3" 3" M90 ET0 3/8" 3/8" M16 ET1 1/2" 1/2" M20 ET2 3/4" 3/4" M25 ET3 1" 1" M32 ET4 1-1/4" 1-1/4" M40 ET5 1-1/2" 1-1/2" M50 ET6 2" 2" M75 ET7 2-1/2" 2-1/2" M75 ET8 3" 3" M90 0 2 1 3 2 6 3 15 4 20 5 30 6 50 7 100 8 150 D 3s s DL PTD ET NW M 142 - Feam Catalogue 01 Ex Cable Glands CABLE GLANDS ACCESSORIES – Technical Features REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. LOCKNUTS DETAIL A THREADS / SIZE TYPE NPT UNI-228 ISO GASKETS DETAIL B THREADS / SIZE TYPE NPT UNI-228 ISO WASHERS TYPE ØD [mm] DETAIL SHROUDS DETAIL D THREADS / SIZE TYPE NPT UNI-228 ISO EARTHS TAGS DETAIL E THREADS / SIZEE TYPE NPT UNI-228 ISO SILICON SEALANT CABLE GLANDS SIZE Q.TY SEALING [ml] SEALING Det.A Det.D Det.E Det.B Det.C

×