SlideShare a Scribd company logo
1 of 17
Download to read offline
Measurement and analysis of optical density profiles of otolith from 
Ps. georgianus and Ch. gunnarii. 
Ryszard Traczyk 
Introduction. 
Analysis of cross-sections and whole otoliths, for their growth poses many difficulties, it is very tedious and time consuming. Results of analyzes are very different, largely depends on the method used, the individual researcher's experience, as well as his physical and mental abilities: visual acuity of vision - the distinction of color, degree of fatigue, or memory of experiments in the large number of observations and measurements derived under the microscope. There are only stored information which are research purpose, additional are lost. 
In this paper, a variety of investigation and measurement of otolith increments were performed by computer measurement and harmonic analysis of the optical density - daily and other otoliths increments are repeated several times at intervals of time and space. 
The peaks of optical density of daily increments in otoliths mackerel icefish were more suppressed by noise records than South Georgia icefish. Ch. gunnarii is a pelagic fish, where there are more noises and Ps. georgianus is more demersal, where its gets less noises. Statistical significance for power of daily increments peaks was tested. 
For nuclei of larval otoliths of Pseudochaenichthys georgianus average width of daily increments was 9.41 * 10-4 mm. Width of daily otolith increments for juvenile of Champsocephalus gunnarii were 0.0024 mm. Cyclical increments in larval otoliths of Ps. georgianus proceeded by a sine wave: y=3,42sin( x[mm] -0,08)+235,1, and for juvenile of Ch. gunnarii by a sine wave: y=3,82sin( x[mm] -24,83)+90. 
Materials and Methods. 
Measurements of optical density of otolith increments were carried out from digital photos of otolith slices, obtained by the excision of otoliths, two-sided grinding, polishing and etching with EDTA (1). Optical density measurements were performed in the program "Fiji image" developed for visualization and measurements of microscope images (2). The otolith material were collected during research cruises on the RV. "Professor Siedlecki" (3; 1). 
The images were processed to measurements: contrast was optimized, background was cleared, the SI mm unit was setup. For each change its optical density profile were recorded with 1231 measurements along otoliths radius and stored. Further study were on pictures with background evenly to dark. 
Exploration and study of cyclic variation of optical density of increments otoliths were carried out three ways: 
1) Spectral analysis and REDFIT procedures of statistical package PAST (4; 5), utilizing Fourier transformation algorithm of Lomb’s periodogram (6; 7; 8; 9); 
2) the procedure for the fitting sinusoid to the empirical data using program PAST. 
3) minimizing the sum of squares of model deviations from the empirical data using Excel Solver tool.
Fig. 1. Image processing, contrast optimization, extraction and reset the background. 
In the model REDFIT the procedure to increase the number of points on the frequency axis was used (5) - after passing the series test fitting empirical data to red noise model (5). 
Average cycle of daily increments was determined by moving a series of measurements (713 for Ps. georgianus and 503 for Ch. gunnarii) of the optical density along whole density profile of the same otolith radius (which retains a fixed number for subtracted value) and determining the first minimum in sums of squared differences of optical density in the adjacent of each measure of series. The distance in moving from the initial difference of none (0 - subtract the same value) to the first minimum was adopted for the period: 24 h periodicity unit. 
A series of 713 measurements were selected from the optical density profile of otolith of Ps. georgianus starting from measure No 7 from the edge nucleus to the 720 measure along the radius – because measurements began not exactly from the edge, but before it and additionally the initial marginal, usually unclear measurements should be excluded from the analysis of the pattern. 
Fig. 2. Measuring the density of the image having background aligned. Determination of the period between troughs. In column D is the subtraction of series after its first shifts (subtraction without any move produces a sum of squared difference equal to 0). Subtraction series after its 16 time shift resulted in second column of S giving minimum sum of squared differences. In further columns that sums grow. The blue line - series of 1231 optical density measurements, green - 713 initial measurements from 7 to 720 measurement that were subject to move with one unit measurement: every 0.000059 mm. 
A series of 503 measurements of the otolith optical density of Ch. gunnarii, were selected from its profile on radius from 507 measure from the edge to the 1009 measure.
Fig. 3. Profile of the optical density of otolith nuclei of Ch. gunnarii (r = 0.04 mm), with reset the background. 
Fig. 4. Profile of the optical density extended outside of otolith nucleus of Ch. gunnarii (r = 0.22 mm), with reset the background.
Fig. 5. Profile of the optical density for cross section of otolith of Ch. gunnarii (r = 0.44 mm), with reset the background. 
Fig. 6. Measurement of the optical density of the images having reduced background. Determination of the period between troughs. Column D contain results of the subtraction of series after its first shifts. Subtraction series after the moving of one of two with about six units resulted in second minimum sum of squared differences placed in column I. Shift by next six unit gave third minimum Sum in column N. Shift by next six unit gave minimum No 4. The blue line - series of 1615 optical density measurements, green - middle 503 measurements from 507 to 1009, that were moved with unit: the distance between measurement equal to 0.0004 mm. 
Shifts of large series of measurements form a representative unit of daily increment.
Results 
Pseudochaenichthys georgianus. 
The average period of diurnal cycling in the increments specified by relative displacement of 713 measurements became 9.41 * 10-4 mm = 941 nm. Harmonic analysis Lomb-Scargl in the program PAST indicated the presence in the otolith increments two statistically significant periodicity: daily and 8-daily. A large portion of the variability of the analyzed record still have the transformations above daily periodicity in the echo effects: peak No 3 of 5 daily cycle, and peaks No 4 and 5 of circadian cycles. 
Fig. 7. Participation sinusoids in the variability of density record. The dotted and dashed lines define the probability levels for which the harmonics included there in the part of the noise generated by it. Peaks 1-5 with a power above the level of 11.87, with a frequency of 0.0075 cycles / 60 nm, have a probability close to 0, which is equal to and less 0.01, which means that in the analyzed series of space - time there are exists cyclicality with such frequencies. 
Other harmonics have a smaller share of variability and can be a large percentage of noise - are generated randomly by the noise. 
However, in the procedure fit profile to tested the red noise model (used to analyze the signals common in the the marine environment), MonteCarlo simulation test 99% show that in the analyzed variation can not be identified significantly strong periodicity, which would not have been generated by incidental noise, beyond the peak four-hour cycle. The use this model here is appropriate, as indicated by series test. 
Fig. 8. Spectral analysis of the optical density of otolith increments for fitting spectrum data to the red noise model (5). Because at test, fitting sample to the model, the number of runs 171 has been set at 5% confidence interval of: 161-198, the above noise model is appropriate for the tested series, which contains not a strong periodicities. Plot of curves of χ² and Monte Carlo for studies of statistical significance of power of peaks. Calculate the critical level indicator (False-al.) the probability of random creation of a sine wave: here in 99.86% a sine wave is generated by noise -enters into its composition. 
As it was small sample for above procedure, the number of points on the frequency axis 
0 
2 
4 
6 
8 
10 
12 
14 
16 
18 
20 
22 
24 
26 
0 
0,1 
0,2 
0,3 
0,4 
0,5 
p(random) = 0,000000009961 
moc~A2 
poziom 0,01 = 11,87 
poziom 0,05 = 10,24 
frequency 
Peak1 f= 0,007528 cycles per 59 nm, or per 1,5 h; 0,0078 mm/cycle, or 8 days/cycle 
Peak3 f = 0,013305 cycles per 59 nm, or per1,5 h; 0,0044 mm/cycle, or 5 days/cycle 
Peak5 f = 0,05007 cycles per 59 nm, or per 1,5 h; 0,001 mm/cycle, or 1,25 day/cycle 
Peak4 f = 0,051996 cycles per 59 nm, or per 1,5 h; 0,001 mm/cycle, or 1,2 day/cycle 
Peak2 f = 0,0649 cycles per 59 nm, or per 1,5 h; 0,001 mm/cycle, or 1 day/cycle 
power ~A² 
level 0.01=11.87 
level 0.05=10.24 
0 
1000 
2000 
3000 
4000 
5000 
6000 
7000 
0 
0,1 
0,2 
0,3 
0,4 
0,5 
τ: 2,2696, Bnwith: 0,001692, False-al.: 99,86 
moc 
chi2 99% 
chi2 95% 
Teoret.AR(1) 
Monte Carlo 95% 
Monte Carlo 99% 
krytycz. Chi2 
frequency 
Peak1 f = 0,00699 cycle per 59 nm, or per 1,5 h.; 0,0084 mm/cycle, or 9 days/cycle 
Runs Test: k=171 is in 5% aceptance interval: 161-198. 
Peak3 f =0,039 cycle per 59 nm, or per 1,5 h.; 0,002 mm/cycle, or 1,6 day/cycle 
Pea4 f=0.05175 cycle per 59 nm, or per 1.5 h.; 0.001 mm/cycle, or 1.2 day/cycle 
Peak5 f=0.064336 cycle per 59 nm, or per1.5 h.; 0.0009 mm/cycle, or 1 day/cycle 
Peak2 f=0.2112 cycle per 59 nm, or per 1.5 h.; 0.0003 mm/cycle, or 7 h./cycle 
Peak6 f=0.35524 cycle per 59 nm, or per 1,5 h 
0.00017 mm/cycle, or 4 h./cykl 
power 
99%χ² 
95%χ² 
Theoret. AR(1) 
99%Monte Carlo 
95%Monte Carlo 
Crit.level χ²
was doubled that give periodicity considerably strong. 
0 
1000 
2000 
3000 
4000 
5000 
6000 
7000 
0 0,01 0,02 0,03 0,04 0,05 0,06 0,07 0,08 0,09 0,1 
Moc χ² 99% 
χ² 95% Teoret.AR(1) 
frekw 
Pik1 f =0,0073427 cykli na 59 nm, lub w 1,5 godz., a to jest 0,008 mm/cykl, lub 8,5 doby/cykl 
Pik3 f =0,013287 cykli na 59 nm, lub w 1,5 godz., a to jest 0,0044 mm/cykl, lub 4,7 doby/cykl 
Pik5 f =0,05 cykli na 59 nm, lub w 1,5 godz., a to jest 0,001 mm/cykl, lub 1,3 doby/cykl 
Pik4 f =0,052098 cykli na 59 nm, lub w 1,5 godz., a to jest 0,001 mm/cykl, lub 1,2 
Pik2 f =0,065035 cykli na 59 nm, lub w 1,5 godz., a to jest 0,001 
mm/cykl, lub 1 doba/cykl 
Pik7 f =0,01958 cykli na 59 nm, lub w 1,5 godz., a to jest 0,003 mm/cykl, lub 3,2 doby/cykl 
Pik6 f =0,039161 cykli na 59 nm, lub w 1,5 godz., a to jest 0,0015 mm/cykl, lub 1,6 
Fig. 9. By increasing the number of points on the frequency axis, two considerably periodicity in otolith increments, were 
underlined (by 99%χ²): 8.5 diurnal cycle and 1 daily. Less significant (under 99%, overgrove 95% Monte Carlo) were 
circadian cycles. The variability of otolith increments have a large share of periodicity of 5, 3 and 2 daily cycles - 
transformations from one to more daily cycles in echo effects (7). Symbols as in above figure. 
Sinusoidal curve fitting. The first seven sinusoids (y=Ansin( 
x + φn)+const.) matched 
to empirical measurement of optical density well explains the variation of the optical density of 
otolith increments. 
Two sine waves in the first look dominate: one daily and 8 daily cycle, as in the spectral 
analysis. Parameters derived: amplitude - A period - T phase - φ, were similar to those 
measured with known periods in spectral analysis, Tab. 1. 
Fig. 103 Fitting empirical 713 measurements by model composed of seven sinusoids.. 
Most closely fitted course of the 7 main sinusoids, were determined by optimizing all 22 
parameters to minimizing the sum of squared deviations of the model, yi from empirical data, 
ye. This sum amounted to min|Σ(yi-ye)2|=72257,5. Such estimates for previous methods were 
higher. 
As a result calculation of the third method it was obtained that the strength of periodicity 
(proportional to A2) comes from two main cycles: the first 8 daily cycle A1 = 4.52 (T1 = 0.00789 
mm, φ1 = -2.64) and the second daily cycle, A2 = 3.42 (T2 = 0.00091 mm, φ2 = -0.08. Constans 
= 235.1. 
Variability in optical density of the otolith, still explain the circadian sinusoid: 1.2 of daily 
180 
190 
200 
210 
220 
230 
240 
250 
260 
0 0,01 0,02 0,03 0,04 
nucleus edge 
gęst. optyczna fragmentu promienia jądra, N = 713 pomiarów y dopasowane, nieznane A, T, φ: 
mm 
unknown A, T, φ: A 1=4,51, φ1=-2,41, T1=0,007955; A2=3,49, φ2=-0,566, T2=0,000908; A3=3,19, φ3=-3,11, T3=0,004395; A4=3,28, φ4=1,1, 
T4=0,001124; A5=2,96, φ5=-2,98, T5=0,001495; A6=2,77, φ6=-1,68, T6=0,002959; A7=2,7, φ7=2,8, T7=0,002111; stała =235,1 
χ² = 72951; R² = 0,27408; p = 1,7577E-42; Akaike IC = 72979; Σ(yₑ-yₓ)²=72951; Σ(yₓ-yₓ)²=5837 
optical density of nucleus radius, N=713 measurements y fitted, unknown A, T, φ
cycle A4 = 6.07 (T4 = 0.00114 mm, φ4 = 0.81) and 1.3 of daily cycle: A5 = 5.33 (T5 = 0.00115 mm, φ5 = -2.87). 
3 cycles of other incorporated into the model are likely to be interpreted as transformation of the first – daily cycle in echo effect: 5 daily with A3 = 3.31 (T3 = 0.00446 mm, φ3 = 3.11), 3 daily with A7 = 2.79 (T7 = 0 , 00299 mm, φ7 = -3.21) and 2 daily A6 = 3.11 (T6 = 0.0015 mm, φ6 = 3.89). Existence of harmonic component with a frequency of daily increment determines the frequencies of multiple components: the effects of jumps in periods of 2 *, 3 *, 4 * daily, etc. 
Tab. 1. Sinusoids parameters (Ps. georgianus larvae), daily increments in bold. 
From spectral analysis of PAST. 
From fitting sinusoids of PAST. 
From minimizing the sum of squared deviations 
No 
A 
φ 
T 
Const. 
A 
φ 
T 
Const. 
A 
φ 
T 
Const. 
1 
Sin 
4,47 
-2,53 
0,008011 
235,1 
4,51 
-2,41 
0,007955 
235,1 
4,5153 
-2,6358 
0,007892 
235,1 
2 
Sin 
3,39 
-0,0911 
0,000905 
χ² 
3,49 
-0,566 
0,000908 
χ² 
3,4242 
-0,082 
0,000906 
3 
Cos 
3,29 
2,95 
0,004427 
73979 
3,19 
-3,11 
0,004395 
72951 
3,3089 
3,1087 
0,004461 
4 
Sin 
2,88 
0,516 
0,001129 
R² 
3,28 
1,1 
0,001124 
R² 
6,0728 
0,8111 
0,001141 
5 
Cos 
2,36 
-1,5 
0,001177 
0,26384 
2,96 
-2,98 
0,001495 
0,27408 
5,3267 
-2,8712 
0,001154 
6 
Sin 
2,97 
2,97 
0,0015 
P 
2,77 
-1,68 
0,003 
p 
3,1081 
3,8871 
0,001504 
7 
sin 
2,71 
-2,44 
0,003004 
2,3727E-40 
2,7 
2,8 
0,002111 
1,7577E-42 
2,7912 
-3,2104 
0,002986 
Fig. 11. The results of measurements approximated by model consisting of seven sinusoids with the use Excel Solver tool - it's hard to count them. The increments pattern have changes, one just 0,027 mm from the edge of the otolith nucleus. 
Fig. 12. The base periodicity: unite of daily increments with nine daily - number of them along nucleus radius. 
180 
190 
200 
210 
220 
230 
240 
250 
260 
0 
0,01 
0,02 
0,03 
0,04 
nucleus edge 
gęst. optyczna fragmentu promienia jądra, N = 713 pomiarów 
solver Σ1-7(An*sin(2πx/Tn+φn))+const. 
mm 
solver: A1=4,52, φ1=-2,64, T1=0,00789; A2=3,42, φ2=-0,08, T2=0,00091; A3=3,31, φ3=3,11, T3=0,00446; A4=6,07, φ4=0,81, T4=0,00114; A5=5,33, φ5=-2,87, T5=0,00115; A6=3,11, φ6=3,89, T6=0,0015; A7=2,79, φ7=-3,21, T7=0,00299; stała =235,1 
Σ(yₑ-yₓ)²=72257,5 
optical density of nucleus radius, N=713 measurements solver tool Σ1-7(An*sin(2πx/Tn+φn))+const. 
225 
235 
245 
0 
0,01 
0,02 
0,03 
0,04 
nucleus edge 
Σ1,2(Asin(2πx/T +φ))+cons 
mm 
A1=4,52, φ1=-2,64 T1=0,00789; A2=3,42, φ2=-0,08, T2=0,00091; stała =235,1
Fig. 13. Sinusoidal components: the daily cycle and circadian, their increments number in the section of nucleus radius of otolith - they overlap (they can be passing at the same layer on the joint surface goes in negative and positive curvatures). 
Fig. 14. Sinusoidal components: multiple echo effects (reflections from the parallel walls): several daily cycles - their increments number in the section of nucleus radius of otolith. Mixing the direct signal with the reflected - delayed signal. In otolith sound speed is 3.5 times higher than in the endolymph. 
Adding to model the four-hour periodicity, y6=0,37sin( x[mm] +4,82)+235,1 , Fig. 8, increases the fit of the model (increases the amplitude of circadian growth). But no eliminates changes in the formula growth – f.e. abnormal one at 0.027 mm distance from the nucleus edge, Fig. 11. These optical density profiles of otolith nuclei of Ps. georgianus larvae complement previously presented otolith profiles of optical density and widths of daily increments for juvenes and adults this species (1): 0.00091 mm for larvae; 0.00284 mm for juvenes; 0.0034 mm for adults. 
Champsocephalus gunnarii. 
Moving the 503 measurements of increments periodicity in relation to adjacent otolith increments determined the average daily otolith growth for larvae of Ch. gunnarii amounting to 0.0024 mm. Average daily increments of this width in the measured radius otolith equals to 0.43 mm can be 180. Harmonic analysis Lomb-Scargl’s, did not give the results of such a strong periodicity for these daily increments. They were drowned out by large number of strong signals with periods of 0.03 mm. 
227 
229 
231 
233 
235 
237 
239 
241 
0 
0,01 
0,02 
0,03 
0,04 
nucleus edge 
y2=3,39sin(2πx/0,001+-0,08)+235,1 
y4=6,84sin(2πx/0,001+0,85)+235,1 
y5=6,1cos(2πx/0,001+-2,98)+235,1 
mm 
A2=3,42, φ2=-0,08, T2=0,00091; A4=6,07, φ4=0,81, T4=0,00114; A5=5,33, φ5=-2,87, T5=0,00115; const. =235,1 
231 
233 
235 
237 
239 
0 
0,01 
0,02 
0,03 
0,04 
nucleus edge 
y3=3,36cos(2πx/0,004+3,02)+235,1 
y6=3,06sin(2πx/0,002+4,01)+235,1 
y7=2,05sin(2πx/0,003+-1,41)+235,1 
A3=3,31, φ3=3,11, T3=0,00446; A6=3,11, φ6=3,89, T6=0,0015; A7=2,79, φ7=-3,21, T7=0,00299; const. =235,1 
mm
Fig. 15. Decomposition of spatial periodicity of optical density of otoliths for sinus and cosine components. Meaning of symbols as in Fig. 7. 
Diurnal periodicity in the optical density profile of otoliths Ch. gunnarii really stand Redfit model for red noise. Because the measurement range is large in relation to the growth cycles, it was partitioned into 3 equal segments for averaging the resulting spectrum, which reduces the noise (4). In the model, the number of points on the frequency axis is concentrated twice. 
Despite negative a runs test for fit to the red-noise model, it was used to investigate the statistical significance of the component peaks. Simulations 99% of Monte Carlo model showed that there are only two significant spectral peaks: daily and 54 daily increments. These sinusoids over goes 99.88% False-alarm level, which includes probability of random to be generated by noise, Fig. 16. 
Fig. 16. The spectrum of sinusoids in red noise model REDFIT. A. Meaning of symbols as in Fig. 8. 
0 
10 
20 
30 
40 
50 
60 
70 
80 
90 
100 
110 
120 
0 
0,01 
0,02 
0,03 
0,04 
0,05 
0,06 
0,07 
0,08 
0,09 
0,1 
0,11 
0,12 
0,13 
0,14 
0,15 
0,16 
0,17 
0,18 
0,19 
0,2 
p(random) = 1,396E-47 
Moc ~A² 
Theor.AR(1) 
poziom 0,01 = 12,29 
poziom 0,05 = 10,65 
Frequency 
Peak1 f =0.0030998 cycle per 0.0004 mm, or per 4 h., 0.129 mm/cycle, or 54 days/cycle 
Peak2 f =0.00077495 cycle per 0.0004 mm, or per 4 h., 0.52 mm/cycle, or 215 days/cycle 
Peak3 f =0.0023249 cycle per 0.0004 mm, or per 4 h. 
0.172 mm/cycle, lub 72 days/cycle 
Peak4 f =0.0015499 cycle per 0.0004 mm, or per 4 h. 
0.258 mm/cycle, or 108 days/cycle 
Peak5 f =0.0080595 cycle per 0.0004 mm, or per 4 h. 
0.05 mm/cycle, or 21 days/cycle 
Peak6 f =0.012477 cycle per 0.0004 mm, or per 4 h. 
0.032 mm/cycle, or 13 days/cycle 
Peak7 f =0.014492 cycle per 0,0004 mm, or per 4 h. 
0.028 mm/cycle, or 12 days/cycle 
Peak8 f =0.023869 cycle per 0.0004 mm, or per 4 h. 
0.017 mm/cycle, or 7 days/cycle 
Peak12 f =0.16669 cycle per 0.0004 mm, or per 4 h. 0.002 mm/cycle, 
or 1 day/cycle 
Peak11 f =0.11268 cycle per 0.0004 mm, or per 4 h.; 0.004 mm/cycle, or 1 day/cycle 
Peak10 f =0.08943 cycle per 0.0004 mm, or per 4 h. 
0.0045 mm/cycle, or 2 days/cykl 
Peak9 f =0.054324 cycle per 0.0004 mm, or per 4 h. 
0.007 mm/cycle, or 3 days/cycle 
power ~A² 
Theor. AR(1) 
level 0.01=12.29 
level 0.05=10.65 
9 
10 
6 
5 
3 
4 
8 
2 
7 
1 
0 
20000 
40000 
60000 
80000 
100000 
120000 
140000 
160000 
180000 
200000 
0 
0,01 
0,02 
0,03 
0,04 
0,05 
0,06 
0,07 
0,08 
0,09 
0,1 
0,11 
0,12 
0,13 
0,14 
0,15 
0,16 
0,17 
0,18 
0,19 
0,2 
0,21 
0,22 
Moc ~A² 
95%χ² 
99%χ² 
kryt.χ² 
95%M.Carlo 
99%M.Carlo 
Teor.AR(1) 
Frequency 
Peak₃ f =0.16667 cycle per 0.0004 mm, or per 4 h.; 0.0024 mm/cycle, or 1 d./cycle; 
Peak₄ f =0.17162 cycle per 0.0004 mm, or per 4 h.; 0,002 mm/cycle, or 1 d./cycle; 
Peak₅ f =0.11276 cycle per 0.0004 mm, or per 4 h.; 0.003547 mm/cycle, or 1 day/cycle 
Peak₆ f =0.089219 cycle per 0.0004 mm, or per 4 h.; 0.004483 mm/cycle, or 2 days/cycle; 
Peak₇ f =0.21747 cycle per 0.0004 mm, or per 4 h.; 0.002 mm/cycle, or 1 day/cycle; 
Peak₈ f =0.18401 cycle per 0.0004 mm, or per 4 h.; 0.002 mm/cycle, or 1 day/cycle; 
Peak₉ f =0.0080545 cycle per 0.0004 mm, or per 4 h.; 0.05 mm/cycle, or 21 days/cycle; 
Peak₁₀ f =0.012392 cycle per 0.0004 mm, or per 4 h.; 0.0323 mm/cycle, lub 13 days/cycle; 
Peak₁ f =0.0030979 cycle per 0.0004 mm, or per 4 h.; 0,129 mm/cycle, or 54 d./cycle; 
Peak₂ f =0.20694 cycle per 0.0004 mm, or per 4 h.; 0.002 mm/cycle, or 0.8 day/cycle, 
τ: 7,0239, Bnwith: 0,001499, False-alarm: 99,88; oversample: 2; segments: 3 
p(random) = 5,96E-48; Runs test for fit to the red noise model: k=348 is outside 5% acceptance interval: 379-431. 
strong periodic components. 
power ~A² 
95%χ² 
99%χ² 
Crit.level χ² 
95%Monte Carlo 
99%Monte Carlo 
Theoret. AR(1)
Fig. 17. The spectrum of sinusoids in red noise model REDFIT. B. Meaning of symbols as in Fig. 8. 
Obtained above the frequency of daily increments, being the subject of studies, provide data about the period of this process, which is a cyclic record of periodic signals that cause cyclical changes in component concentrations and pressure of endolymph. 
The peak frequency of daily increments from research reached 0.16667 cycles per unit - per 0.0004 mm, intervals of which measurement was performed. Hence one cycle - the daily growth period of otolith Ch. gunnarii is 0.0024 mm. Thus obtained periods of other peaks were used to determine the component equations of periodicity in the otolith increments. 
Fig. 18. The empirical record of optical density from otoliths of Ch. gunnarii and harmonic characteristics of the two components from their cyclical increments: daily, 0.0024 mm wide and weekly, 0.02 mm of the displaced series of 503 measurements. 
6 
5 
3 
4 
8 
2 
7 
0 
1000 
2000 
3000 
4000 
5000 
6000 
7000 
8000 
9000 
0,085 
0,095 
0,105 
0,115 
0,125 
0,135 
0,145 
0,155 
0,165 
0,175 
0,185 
0,195 
0,205 
0,215 
Moc ~A² 
95%99%kryt.χ² 
95%M.Carlo 
99%M.Carlo 
Teor.AR(1) 
Frequency 
Peak₃ f =0.16667 cycle per 0.0004 mm, or per 4 h.; 0.0024 mm/cycle, or 1 day/cycle; 
Peak₄ f =0.17162 cycle per 0.0004 mm, or per 4 h.; 0.002 mm/cycle, or 1 day/cycle; 
Peak₅ f =0.11276 cycle per 0.0004 mm, or per 4 h.; 0.003547 mm/cycle, or 1 day/cycle 
Peak₆ f =0.089219 cycle per 0.0004 mm, or per 4 h.; 0.004483 mm/cycle, or 2 days/cycle; 
Peak₇ f =0.21747 cycle per 0.0004 mm, or per 4 h.; 0.002 mm/cycle, or 1 day/cycle; 
Peak₈ f =0.18401 cycle per 0.0004 mm, or per 4 h.; 0.002 mm/cycle, or 1 day/cycle; 
Peak₂ f =0.20694 cycle per 0.0004 mm, or per 4 h.; 0.002 mm/cycle, or 0.8 day/cycle 
τ: 7,0239, Bnwith: 0,001499, False-al.: 99,88; 
oversample: 2; segments: 3 
p(random) = 5,96E-48; 
Runs test for fit to the red noise model: 
k=348 is outside 5% acceptance interval: 379-431. 
strong periodic components 
power ~A² 
95%χ² 
99%χ² 
Crit.level χ² 
95%Monte Carlo 
99%Monte Carlo 
Theoret. AR(1) 
0 
10 
20 
30 
40 
50 
60 
70 
80 
90 
100 
110 
120 
130 
140 
150 
160 
170 
180 
0,1 
0,11 
0,12 
0,13 
0,14 
0,15 
0,16 
0,17 
0,18 
0,19 
0,2 
Moc ~A² 
y₁=29,27sin(2πx/0,026+0,37)+85 
Σᵢ₌₁₋₂(Aᵢ*sin(2πx/Tᵢ+φᵢ))+const. 
A₁=29,27, φ₁=0,37, T₁=0,0257; A₂=24,6, φ₂=-0,119, T₂=0,0024; ; 
mm 
Power ~A²
Fig. 19. The empirical record of optical density from otoliths of Ch. gunnarii and harmonic characteristics of the nine components from their cyclical increments of the displaced series of 503 measurements. 
Fig. 20. Fitting harmonic equations to empirical records of optical density in the otoliths Ch. gunnarii, PAST determine function of circadian increments - green line (R2 = 0.77 is for above function that have a fixed sinusoid of daily increments - No. 8. Without of this daily sinusoid harmonic obtains higher R2). With Solver tool using minimizing the sum of squared deviations periodicity of daily increments is determined from empirical data as the seventh component of the model (double line). 
0 
10 
20 
30 
40 
50 
60 
70 
80 
90 
100 
110 
120 
130 
140 
150 
160 
170 
180 
0,1 
0,11 
0,12 
0,13 
0,14 
0,15 
0,16 
0,17 
0,18 
0,19 
0,2 
Moc ~A² 
Σᵢ₌₁₋₉(Aᵢ*sin(2πx/Tᵢ+φᵢ))+const. 
mm 
solver: A₁=29,27, φ₁=0,37, T₁=0,02574; A₂=2,98, φ₂=1,72, T₂=0,00193; A₃=24,6, φ₃=-0,12, T₃=0,0024; A₄=28,8, φ₄=2,22, T₄=0,00233; A₅=14,8, φ₅=-0,15, T₅=0,00355; A₆=4,1, φ₆=0,06, T₆=0,00448; A₇=3,24, φ₇=0,2, T₇=0,00184; A₈=10,2, φ₈=-2,74, T₈=0,00217; A₉=5,96, φ₉=-2,38, 
T₉=-0,0458, const = 85 
Σ(yₑ-yᵢ)²=871443 
Power ~A² 
0 
10 
20 
30 
40 
50 
60 
70 
80 
90 
100 
110 
120 
130 
140 
150 
160 
170 
180 
190 
200 
0,1 
0,11 
0,12 
0,13 
0,14 
0,15 
0,16 
0,17 
0,18 
0,19 
0,2 
Moc ~A² 
Σᵢ₌₁₋₉(Aᵢ*sin(2πx/Tᵢ+φᵢ))+const. 
dopasowane, nieznane A, T, φ: 
y₇=3,33sin(2πx/0,0021-6,78)+85 
mm 
unknown A, T, φ: A₁=24,2, φ₁=2,19, T₁=0,0248; A₂=25,1, φ₂=-0,242, T₂=0,0331; A₃=17,1, φ₃=-0,881, T₃=0,0662; A₄=16,4, φ₄=-1, T₄=0,0209; A₅=11,7, φ₅=-2,7, T₅=0,0124; A₆=7,44, φ₆=0,437, T₆=0,0058; A₇=7,13, φ₇=-0,876, T₇=0,0083; A₈=1,97, φ₈=-2,22, T₈=0,0024; 
A₉=18,26, φ₉=-9,64, T₉=-0,07012; const. =85; Σ(yₑ-yᵢ)²=330042 
A₉=5,96, φ₉=-2,38, T₉=0,0064; 
const. =89,05 
solver: A₁=31,08, φ₁=1, T₁=0,0263; A₂=3,88, φ₂=-2,5, T₂=0,00417; A₃=9,18, φ₃=-3,5, T₃=0,01566; A₄=9,09, φ₄=3,57, T₄=-0,00812; A₅=0,07, φ₅=3,19, T₅=-0,00076; A₆=4,12, 
φ₆=-3,27, T₆=0,005; A₇=3,33, φ₇=-6,78, T₇=0,0021; A₈=9,31, φ₈=-7,28, T₈=0,00577 
y fitted, unknown A, T, φ 
Power ~A²
Fig. 21. Harmonic model fitted to the profile of optical density along of otolith radius of Ch. gunnarii appointed the same formula of a harmonic function as for the moving fragment. It is composed of a two sinusoids: daily increment peak No 3 and 2 weekly increments – peak No 1. First starting from the otolith center, daily increments are slightly narrower and should be measured separately. However, the nucleus of Ch. gunnarii is small, so the problem with the lack of separate measurements is not large: it seems that from 0 to 0.05 mm instead of 2 periods there are 3. 
In spite of the various changes in optical density, eg due to environmental changes, the basic pattern of daily increments remains the same along the whole profile of optical density on otolith radius. There are 179 of them (similar to numbers obtained in the profile displacement). Daily peaks describes y3=3,82sin( x[mm] -24,83)+90. 
Tab. 2. Sinusoids parameters fit to 503 measurements (Ch. gunnarii), daily increments in bold. 
From spectral analysis of PAST. 
From fitting sinusoids of PAST. 
From minimizing the sum of squared deviations (solver) 
No 
f 
A 
φ 
T 
Const. 
f 
A 
φ 
T 
Const. 
A 
φ 
T 
Const. 
1 
sin 
13.7 
2.37 
0.129119 
81.85 
cos 
24.2 
2.19 
0.02481 
89.05 
29.28568448 
0.366804749 
0.025738099 
85 
2 
sin 
2.98 
1.72 
0.001932 
χ² 
sin 
25.1 
-0.242 
0.033090 
χ² 
3.133956642 
1.062888152 
0.001932927 
Σ(yₑ-yᵢ)² 
3 
cos 
24.6 
-0.119 
0.002399 
222570 
cos 
17.1 
-0.881 
0.06622 
160410 
1.444064802 
-21.4882443 
0.002399952 
465807 
4 
sin 
28.8 
2.22 
0.002330 
R² 
sin 
16.4 
-1 
0.020890 
R² 
-0.239585307 
-16.98166601 
0.002330731 
5 
cos 
14.8 
-0.153 
0.003547 
0.684 
cos 
11.7 
-2.7 
0.012400 
0.77196 
3.66552516 
0.744563692 
0.003547357 
6 
sin 
4.1 
0.0589 
0.0045 
P 
sin 
7.44 
0.437 
0.0058 
P 
-3.185641848 
-11.31575925 
0.00448335 
7 
sin 
3.24 
0.203 
0.001839 
4.8E-114 
sin 
7.13 
-0.876 
0.008268 
1.54E-148 
-0.988937091 
-3.94738222 
0.001839334 
8 
sin 
10.2 
-2.74 
0.002173 
Akaike IC 
sin 
1.97 
-2.22 
0.002399 
Akaike IC 
1.019973039 
-17.74347848 
0.002173795 
9 
222538 
sin 
5.96 
-2.38 
0.006401 
160410 
4.853205895 
6.200844788 
0.006401000 
Tab. 3. Sinusoids parameters fit to all 1614 measurements (Ch. gunnarii), daily increments in bold. 
From minimizing the sum of squared deviations (solver) 
No 
f 
A 
φ 
T 
Const. 
1 
sin 
11.34678543 
-1.825153025 
0.024976809 
89.61 
2 
sin 
2.250685872 
2.289589021 
0.001937818 
Σ(yₑ-yᵢ)² 
3 
cos 
3.817085043 
-24.83181682 
0.00238518 
3577583 
4 
sin 
-0.222998561 
-24.96633606 
0.00229975 
5 
cos 
3.601751213 
-1.707692003 
0.003529968 
6 
sin 
-2.177121558 
-1.413467857 
0.004584774 
7 
sin 
-1.203566121 
-5.202701474 
0.001832624 
8 
sin 
2.602419876 
-15.24427788 
0.00218312 
9 
sin 
2.512937926 
4.448054353 
0.006367814 
0 
20 
40 
60 
80 
100 
120 
140 
160 
180 
200 
220 
240 
0 
0,05 
0,1 
0,15 
0,2 
0,25 
0,3 
0,35 
0,4 
Moc ~A² 
Σᵢ₌₁₋₉(Aᵢsin(2πx/Tᵢ+φᵢ))+const. 
mm 
solver: A₁=11,35, φ₁=-1,83, T₁=0,02498; A₂=2,25, φ₂=2,29, T₂=0,00194; A₃=3,82, φ₃=-24,83, T₃=0,00239; A₄=-0,22, φ₄=-24,97, T₄=0,0023; A₅=3,6, φ₅=-1,71, T₅=0,00353; A₆=-2,18, φ₆=-1,41, T₆=0,00458; A₇=-1,2, φ₇=-5,2, T₇=0,00183; 
A₈=2,6, φ₈=-15,24, T₈=0,00218; A₉=2,51, φ₉=4,45, T₉=0,00637; const. =90; Σ(yₑ-yᵢ)²=3577583 
Power ~A²
Discussion 
Diurnal increments in otolith satisfy the conditions to describe them as signals periodically variable. Signals – signs of daily increments are multiple repeated at intervals of time: as their name in daily cycle and several repeated at interval of space - here, depending on the species and physiological period: forward every 0.0024 mm for juvenes of Ch. gunnari, or every 0.0009 mm for larvae, 0.0028 mm for juvenes; 0.0034 mm for adults of Ps. georgianus (1). 
The above harmonic parameters of the otolith formation - daily creation of matter describe the cyclical changes in environment, tidal, in magnetic field which, when run in the air are not saved. In endolymph and in liquid two crystal, that form the otolith surface, above cyclical changes are captured in the pattern of daily increments. Endolymph transfers vibrations and waves that act on otolith and on the particles forming them. One theory for perception of sound is based on creating in endolymph a standing wave forming the local density and thinning, and thus charge changes determining the arrangement of otolith substrates. Arrangement laid down by one, short impulse (at higher concentration parallel arrangament) later does not change, because it is captured, recorded in a protein network and as a disorder causes a further growth of the crystal. Design orientations of microparticles formed by micro-changes further determine the macro form. 
Otoliths from larvae are almost spherical, Fig. 1 (1). Otoliths grow with surface layers of mixed crystals of collagen network with aragonite. Ingrowing layers form curved surfaces proper to liquid crystals. Thus, they must be formed, depending on the ambient pressure. The larvae inside the eggs at the early stages of setting up bodies, as eggs float freely, or lie. In a motionless otoliths as detectors of motion, acceleration and environment vibration grow in spherical surfaces because their dipolar substrates are distributed almost everywhere in the endolymph with the same probability, at orientation in accordance with distribution of positive and negative charges, radially around the sphere. For propagated in the sea vibrations, environment noises that to their perception are transferred into the marine animals microscopic otoliths with their high density could be their receiver. Otoliths transfer waves with speed 3.5 times faster than sea water (~5000m/s). 
Endolymph has a concentration and tributary of components regulated that keeps its function and metabolism at the appropriate level. Regulating concentration of the otolith components in the endolymph to equalize the speed of extracting them out from its to the process of crystallization with appropriate its speed, keeps the growth crystal surface at constant diameter with constant dimensions. This determine stability increments and the range of variation determined by changes in endolimfie. When the crystallization rate is higher than the rate of removing substrates from endolymph, the crystal diameter is increasing and vice- versa (10) [str. 456]. Process of otolith growth depends on laying the collagen fibers in the matrix in which their gaps aragonite crystallizes in sizes limited by these gaps. 
Analyzed vibration, background noise in endolymph, carry cycling to densities of its components, to distribution of charges and to other parameters of the endolymph property, that changes the orientation of the dipoles of otoliths precursors. There are subject to cyclic concentration, accelerating crystallization alternately by recrystallization, facilitating the alignment of both component and the interpenetration into crystallized matrix of otolith.
For small larvae of Antarctic fish, the vital information about the environment provide to them vibration and noise from the sea: about the presence of ice, about the presence of krill forming various concentrations depending on the environment (11), and thus the background noise. This information allows them to locate food, threats, hiding. Because of that from the start of growth of larval runs specialization of organ vibration perception - otoliths to these sounds and vibrations, which determines their free life in the sea (12). Organisms without otolith, or statoliths is sedentary, associated with the bottom (13). For fish larvae may be less important sounds generated by large marine organisms, but with the development, and through development – growth of otolith, this organ of perception will recognize them. Width of daily increments of Ps. georgianus larvae developing in the eggs are narrower than those for juvenile and adult fish (1), living in different zones of the sea. But for juveniles of Ch. gunnari and Ps. georgianus widths of their increments are similar, as they share similar environment. 
The analyzed species perform diurnal vertical migrations, thus periodically changing the acoustic field. With increasing depth sound amplitude decreases (for pressures of 15 dB from 0.00086 to 0.00026 cm, for pressures of 70 dB from 0.48251 to 0.14641 cm) and the speed of sound decreases. 
With the depth noise from the waves disappear and there are conditions that increase the possibility of the perception of weak signals of biological activity. Generally fish are responsive to audio signals, when they are to noise in the ratio of not less than 1/5. Sounds specific to feeding 5000 Hz pressure of 50 N/m2 are received under no noise, from a distance of 70 m (with noise waving 1 ° B from the 3.5 m). Spawning sounds 100 Hz with pressure of 1000 N/m2 are received from a distance of 300 m (at wave of 1 ° B from 30 m, 2 ° B from 10 m, 4 ° B from the 9 m). Environmental noise can help to hear, could result in changes that increase hearing sensitivity. 
Acoustic waves from different sources carry information about the factors changing them in the form specific to those factors emitted frequency and sound pressure. Various changes of acoustic waves from a fixed known source may provide information on factor specific changing the radiated waves (differently amended by the air bubbles, differently from schools of fish or krill and even differently by the bottom, also depending on whether it is muddy, sandy or rocky). Collection this information for the receiving marine organisms provides picture of the environment changes corresponding to the image from the light waves in the atmosphere for organisms equipped with organs of sight. 
Krill in large densities protects larvae of fish, giving them the environment to develop, changing the physico - chemical properties of Antarctic waters on favorable to the development of larvae and juvenes present in its clusters, Fig. 22, (14). High densities of krill form a "moving, living ocean", causing bio-turbulent waters of size effects almost equal to the effect of mixing water in the tide, or with wind action (15; 16) – frequencies for wind are above 100 Hz and sound pressure 48 ÷ 20 ÷ -5 dB. Noise from turbulent flow of water masses also mean the presence of krill - which form there its higher concentrations (11). Ice cover also modifies the sea water, provides shelter and allows fish to extend their propagation for food. Noise caused by moving ice are frequencies 9 ÷ 5000 Hz, wherein the waters of completely ice-covered frequencies are from 1 to 10000 Hz with sound pressure of 45 dB to -15 dB, in which from 40 to 1000 Hz sound pressure run above the average of the minimum the sound pressure of own
noise of sea, i.e. in the range from 20 to 5 dB, in the remaining range is less than that average. 
In the marine environment above noise carry information on changes in the environment, which is mostly in cyclical nature – noise of ice edge is cyclical daily from tides that stand out at the coast of Antarctica, with possibly reflection in the oscillation of the southern edge of the ice cover. 
Fig. 22. Oscillation of the southern edge of the ice cover and occurrence of larvae of fish in the krill fishery (marked by arrows) carried out in the ice marginal zone between South Orkney and Elephant Island during an expedition on rv. "Professor Siedlecki" in season 1988/89 (17). Arrows – krill catches containing fish larvae of the following species: Ch. aceratus (40,66); Ch. gunnarii (41); Chionodraco rastrospinosus (41,66,78); Chaenodraco wilsoni (69,73,74); Dissostichus eleginoides (73); Pleurogramma antarcticum (40,74); Gryodraco antarcticus (40,73,74,82); Neopagetopsis sp. (55); Neopagetopsis ionach (56,71,73); Trematomus eulepidotus (65); Notolepis coatsi (67,71); Pagetopsis sp. (69,78,82); Notothenia sp. (69); Notothenia larseni (73;74); Pagetopsis macropterus (73); Electrona carlsbergi (78). 
To environmental cycles, with the development of organisms synchronize physiological cycles, which at the beginning of synchronization may be reflected in circadian cycles - due to the complex process of adapting many of the currently formed biological, internal functions in the larval development. 
It appears that for fishes does not exist a practical lower limit of sensed sounds. For the range of infrasound (sound waves of low frequency) function of receptors take over the organs of touch. 
Even more simple statolith enable bivalve Donax to choose from complex sounds generated by the waves, the right kind of wave to use it to achieve success in reproduction. 
Conclusions 
Results are probable: larvae physiological cycles are usually circadian - at above model for fish larvae the highest amplitudes are characterized by circadian cycles, A4, A5. They may result from the transformation of the larvae to adapt to the daily cycle. 
Time sinusoid parameters employed to describe time increments of otolith does not necessarily correspond with the parameters of the acoustic waves. Three theories of perception of sounds shall indicate more work in this direction. 
Sine wave of daily increments separated component from sinusoids model, enables fast measurement of their number and width. 
Obtained similar values of mean daily increment in three independent methods: 
1. search for the minimum difference in optical density of otoliths when relative moving their profiles to each other. 
kg/h 
3 kg/h 
14 kg/h 
78 
82 
74 
73 
71 
40 
41 
69 
67 
66 
65 
56 
55
2. harmonic analysis of REDFIT (4). 
3. fit of the harmonic model to empirical data by minimizing the sum of squared deviations. Use solver tool - the most accurate method. 
Records of optical density otolith increments can be a valuable material for the study of biological, physical and evolutionary (13) in the marine environment. 
However, at noise emissions are weak, treated as irrelevant and discarded from the analysis, in the appropriate scale for the micro-level organizations can be important synchronisers of cyclicality - particularly for a large number of larvae - thus determining the mass gain, the success of generations and even existence of a species being closely related to the free way of life in vast, poor at food and raw space of Antarctic Ocean. 
Lack of synchronization conditioning for species their lifestyle adapted to the environment may be partly responsible for the disappearance of that timing-dependent species. No cover surface of the ocean by ice reaching in the 70's up to Georgia Pd, coincides with the long kept decline of fish Pseudochaenichthys georgianus by 75% - despite a ban on their fishing. Meanwhile, the open ocean and bottom species does not associated with the neighborhood of ice edge are present in an amount does not less, but even more (18). 
Cited works 
1. Traczyk, R.J. Zastosowanie analizy mikroprzyrostów i morfologii otolitów georgianki (Pseudochaenichthys georgianus Norman, 1939) z rejonu Georgii Południowej (Antarktyka) do określenia wieku, wzrostu oraz ważniejszych okresów rozwoju ryb. Kraków : Ryszard Traczyk In Altum, ISBN: 978-83-62841-10-3, 2013. 
2. Kota, M. Basics of Image Processing and Analysis. EMBL Heidelberg : Centre for Molecular & Cellular Imaging, 2013. Copyright 2006 - 2013, Kota Miura (http://cmci.embl.de). 
3. Parkes, G., I. Everson, J. Anderson, Z. Cielniaszek, J. Szlakowski, R. Traczyk. Report of the UK/Polish fish stock assessment survey around South Georgia in January 1990. London : Imp.Coll. of Sci. & Techn., 1990, str. 20. 
4. Hammer, Ø. Time series analysis with Past. Oslo : Natural History Museum, University of Oslo., 2010. 
5. Schulz, M., M. Mudelsee. REDFIT: estimating red-noise spectra directly from unevenly spaced paleoclimatic time series. GE : Computers & Geosciences 28, 421-426., 2002. 
6. Kaczkowska, A. Transformacje Fouriera, DFT, FFT, Periodogram Lomba-Scargle’a. Gdańsk : Politechnika Gdańska, 2009. 
7. Kozłowski, E. Analiza spektralna. Wrocław : GUM, Zakł. Fizykocemii, http://bip.gum.gov.pl/, 2013. 
8. NASA. Algorithm Documentation. NJ : NASA Exoplanet Archive, 2012. http://exoplanetarchive.ipac.caltech.edu/applications/Periodogram/docs/Algorithms.html. 
9. UF. Lomb-Scargle Periodogram. FL : University of Florida, EEL, 6537, 2009. 
10. Anonymous, 1983. Encyklopedia Fizyki Współczesnej. W-wa : PWN, 1983. str. 1072. 
11. Witek, Z., J. Kalinowski, A. Grelowski. Formation of Antarctic Krill Concentrations in Relation to Hydrodynamic Processes and Social Behaviour. [aut. książki] D. Sahrhage. Antarctic Ocean and Resources Variability. Berlin : Springer-Verlag, 1988. 
12. Mitrinowicz - Modrzejewska, A. Fizjologia i patologia głosu, słuchu i mowy. W-wa. : Państw. Zakł. Wyd. Lek., 1963. str. 307. 
13. Traczyk, R. Migrations of Antarctic fish Pseudochaenichthys georgianus Norman, 1939 in the Scotia Sea. Hobart : CCAMLR. WG-FSA-12/68 Rev. 1, 2012. 
14. Ślósarczyk, W., Z. Cielniaszek. Postlarval and juvenile fish (Pisces, Perciformes and
Myctophiformes) in the Antarctic Peninsula region the Antarctic Peninsula region, 1983/1984. 1-2. W-wa : Pol. Polar Res., 1985. strony 159-165. Tom 6. 
15. Harmon, K. Shrimpy Sea Life May Mix Oceans as Much as Tides and Winds Do. bio-ocean- mixing. [Online] Scientific American, 29 VII 2009. http://www.scientificamerican.com/article.cfm?id=bio-ocean-mixing. 
16. Pyper, W. Krill mix up the ocean. Tasmania : Australian Antarctic Magazine, 2008. 
17. Traczyk, R. The occurrence of krill Euphausia superba in the floating ice edge zone and some its biological data. http://georgianka.strefa.pl/krill_oc.html. [Online] INTERIA.PL S.A., 1993. 
18. Traczyk, R. Economic competition for high profits from Antarctic living resources in protection area and Mercury contaminants of fish from outside. Hobart : CCAMLR WG-EMM-13/04, 2.1.1, 2013.

More Related Content

What's hot

An Innovative Use of X-ray Computed Tomography in Composite Impact Damage Cha...
An Innovative Use of X-ray Computed Tomography in Composite Impact Damage Cha...An Innovative Use of X-ray Computed Tomography in Composite Impact Damage Cha...
An Innovative Use of X-ray Computed Tomography in Composite Impact Damage Cha...Fabien Léonard
 
Adaptive Noise Reduction Scheme for Salt and Pepper
Adaptive Noise Reduction Scheme for Salt and PepperAdaptive Noise Reduction Scheme for Salt and Pepper
Adaptive Noise Reduction Scheme for Salt and Peppersipij
 
A Study of Total-Variation Based Noise-Reduction Algorithms For Low-Dose Cone...
A Study of Total-Variation Based Noise-Reduction Algorithms For Low-Dose Cone...A Study of Total-Variation Based Noise-Reduction Algorithms For Low-Dose Cone...
A Study of Total-Variation Based Noise-Reduction Algorithms For Low-Dose Cone...CSCJournals
 
CROSS-COMPARISON BETWEEN CHINA HJ1A-CCD AND LANDSAT TM DATA(Guoqing Li).ppt
CROSS-COMPARISON BETWEEN CHINA HJ1A-CCD AND LANDSAT TM DATA(Guoqing Li).pptCROSS-COMPARISON BETWEEN CHINA HJ1A-CCD AND LANDSAT TM DATA(Guoqing Li).ppt
CROSS-COMPARISON BETWEEN CHINA HJ1A-CCD AND LANDSAT TM DATA(Guoqing Li).pptgrssieee
 
CROSS-COMPARISON BETWEEN CHINA HJ1A-CCD AND LANDSAT TM DATA(Guoqing Li).ppt
CROSS-COMPARISON BETWEEN CHINA HJ1A-CCD AND LANDSAT TM DATA(Guoqing Li).pptCROSS-COMPARISON BETWEEN CHINA HJ1A-CCD AND LANDSAT TM DATA(Guoqing Li).ppt
CROSS-COMPARISON BETWEEN CHINA HJ1A-CCD AND LANDSAT TM DATA(Guoqing Li).pptgrssieee
 
An Ultrasound Image Despeckling Approach Based on Principle Component Analysis
An Ultrasound Image Despeckling Approach Based on Principle Component AnalysisAn Ultrasound Image Despeckling Approach Based on Principle Component Analysis
An Ultrasound Image Despeckling Approach Based on Principle Component AnalysisCSCJournals
 
Image Quality - Radiologic Imaging
Image Quality - Radiologic ImagingImage Quality - Radiologic Imaging
Image Quality - Radiologic ImagingMaria Nicole Sicaja
 
Filtering Techniques to reduce Speckle Noise and Image Quality Enhancement me...
Filtering Techniques to reduce Speckle Noise and Image Quality Enhancement me...Filtering Techniques to reduce Speckle Noise and Image Quality Enhancement me...
Filtering Techniques to reduce Speckle Noise and Image Quality Enhancement me...IOSR Journals
 
Performance Assessment of Several Filters for Removing Salt and Pepper Noise,...
Performance Assessment of Several Filters for Removing Salt and Pepper Noise,...Performance Assessment of Several Filters for Removing Salt and Pepper Noise,...
Performance Assessment of Several Filters for Removing Salt and Pepper Noise,...IJEACS
 
New microsoft power point presentation
New microsoft power point presentationNew microsoft power point presentation
New microsoft power point presentationAzad Singh
 
Optimization of Aberrated Coherent Optical Systems
Optimization of Aberrated Coherent Optical SystemsOptimization of Aberrated Coherent Optical Systems
Optimization of Aberrated Coherent Optical SystemsIOSR Journals
 
Noise Reduction in MRI Liver Image Using Discrete Wavelet Transform
Noise Reduction in MRI Liver Image Using Discrete Wavelet TransformNoise Reduction in MRI Liver Image Using Discrete Wavelet Transform
Noise Reduction in MRI Liver Image Using Discrete Wavelet TransformIRJET Journal
 
Total Variation-Based Reduction of Streak Artifacts, Ring Artifacts and Noise...
Total Variation-Based Reduction of Streak Artifacts, Ring Artifacts and Noise...Total Variation-Based Reduction of Streak Artifacts, Ring Artifacts and Noise...
Total Variation-Based Reduction of Streak Artifacts, Ring Artifacts and Noise...Jan Michálek
 
Optimum Image Filters for Various Types of Noise
Optimum Image Filters for Various Types of NoiseOptimum Image Filters for Various Types of Noise
Optimum Image Filters for Various Types of NoiseTELKOMNIKA JOURNAL
 
11.the optical constants of highly absorbing films using the spectral reflect...
11.the optical constants of highly absorbing films using the spectral reflect...11.the optical constants of highly absorbing films using the spectral reflect...
11.the optical constants of highly absorbing films using the spectral reflect...Alexander Decker
 
Survey Paper on Image Denoising Using Spatial Statistic son Pixel
Survey Paper on Image Denoising Using Spatial Statistic son PixelSurvey Paper on Image Denoising Using Spatial Statistic son Pixel
Survey Paper on Image Denoising Using Spatial Statistic son PixelIJERA Editor
 

What's hot (20)

An Innovative Use of X-ray Computed Tomography in Composite Impact Damage Cha...
An Innovative Use of X-ray Computed Tomography in Composite Impact Damage Cha...An Innovative Use of X-ray Computed Tomography in Composite Impact Damage Cha...
An Innovative Use of X-ray Computed Tomography in Composite Impact Damage Cha...
 
Adaptive Noise Reduction Scheme for Salt and Pepper
Adaptive Noise Reduction Scheme for Salt and PepperAdaptive Noise Reduction Scheme for Salt and Pepper
Adaptive Noise Reduction Scheme for Salt and Pepper
 
X ray tomography
X ray tomographyX ray tomography
X ray tomography
 
A Study of Total-Variation Based Noise-Reduction Algorithms For Low-Dose Cone...
A Study of Total-Variation Based Noise-Reduction Algorithms For Low-Dose Cone...A Study of Total-Variation Based Noise-Reduction Algorithms For Low-Dose Cone...
A Study of Total-Variation Based Noise-Reduction Algorithms For Low-Dose Cone...
 
CROSS-COMPARISON BETWEEN CHINA HJ1A-CCD AND LANDSAT TM DATA(Guoqing Li).ppt
CROSS-COMPARISON BETWEEN CHINA HJ1A-CCD AND LANDSAT TM DATA(Guoqing Li).pptCROSS-COMPARISON BETWEEN CHINA HJ1A-CCD AND LANDSAT TM DATA(Guoqing Li).ppt
CROSS-COMPARISON BETWEEN CHINA HJ1A-CCD AND LANDSAT TM DATA(Guoqing Li).ppt
 
CROSS-COMPARISON BETWEEN CHINA HJ1A-CCD AND LANDSAT TM DATA(Guoqing Li).ppt
CROSS-COMPARISON BETWEEN CHINA HJ1A-CCD AND LANDSAT TM DATA(Guoqing Li).pptCROSS-COMPARISON BETWEEN CHINA HJ1A-CCD AND LANDSAT TM DATA(Guoqing Li).ppt
CROSS-COMPARISON BETWEEN CHINA HJ1A-CCD AND LANDSAT TM DATA(Guoqing Li).ppt
 
An Ultrasound Image Despeckling Approach Based on Principle Component Analysis
An Ultrasound Image Despeckling Approach Based on Principle Component AnalysisAn Ultrasound Image Despeckling Approach Based on Principle Component Analysis
An Ultrasound Image Despeckling Approach Based on Principle Component Analysis
 
Thesis Overview
Thesis Overview Thesis Overview
Thesis Overview
 
Image Quality - Radiologic Imaging
Image Quality - Radiologic ImagingImage Quality - Radiologic Imaging
Image Quality - Radiologic Imaging
 
Filtering Techniques to reduce Speckle Noise and Image Quality Enhancement me...
Filtering Techniques to reduce Speckle Noise and Image Quality Enhancement me...Filtering Techniques to reduce Speckle Noise and Image Quality Enhancement me...
Filtering Techniques to reduce Speckle Noise and Image Quality Enhancement me...
 
Performance Assessment of Several Filters for Removing Salt and Pepper Noise,...
Performance Assessment of Several Filters for Removing Salt and Pepper Noise,...Performance Assessment of Several Filters for Removing Salt and Pepper Noise,...
Performance Assessment of Several Filters for Removing Salt and Pepper Noise,...
 
J010245458
J010245458J010245458
J010245458
 
New microsoft power point presentation
New microsoft power point presentationNew microsoft power point presentation
New microsoft power point presentation
 
Optimization of Aberrated Coherent Optical Systems
Optimization of Aberrated Coherent Optical SystemsOptimization of Aberrated Coherent Optical Systems
Optimization of Aberrated Coherent Optical Systems
 
Noise Reduction in MRI Liver Image Using Discrete Wavelet Transform
Noise Reduction in MRI Liver Image Using Discrete Wavelet TransformNoise Reduction in MRI Liver Image Using Discrete Wavelet Transform
Noise Reduction in MRI Liver Image Using Discrete Wavelet Transform
 
Total Variation-Based Reduction of Streak Artifacts, Ring Artifacts and Noise...
Total Variation-Based Reduction of Streak Artifacts, Ring Artifacts and Noise...Total Variation-Based Reduction of Streak Artifacts, Ring Artifacts and Noise...
Total Variation-Based Reduction of Streak Artifacts, Ring Artifacts and Noise...
 
E04542733
E04542733E04542733
E04542733
 
Optimum Image Filters for Various Types of Noise
Optimum Image Filters for Various Types of NoiseOptimum Image Filters for Various Types of Noise
Optimum Image Filters for Various Types of Noise
 
11.the optical constants of highly absorbing films using the spectral reflect...
11.the optical constants of highly absorbing films using the spectral reflect...11.the optical constants of highly absorbing films using the spectral reflect...
11.the optical constants of highly absorbing films using the spectral reflect...
 
Survey Paper on Image Denoising Using Spatial Statistic son Pixel
Survey Paper on Image Denoising Using Spatial Statistic son PixelSurvey Paper on Image Denoising Using Spatial Statistic son Pixel
Survey Paper on Image Denoising Using Spatial Statistic son Pixel
 

Viewers also liked

Internal radiation dosimetry
Internal radiation dosimetryInternal radiation dosimetry
Internal radiation dosimetryNaslinda Rizan
 
spectrophotometry, ultra violet absorption, infra red atomic absorption.
spectrophotometry, ultra violet absorption, infra red atomic absorption.spectrophotometry, ultra violet absorption, infra red atomic absorption.
spectrophotometry, ultra violet absorption, infra red atomic absorption.priya tamang
 
Introduction to laboratory techniques
Introduction to laboratory techniquesIntroduction to laboratory techniques
Introduction to laboratory techniquesLogos Academy
 
Paediatric dose calculation
Paediatric dose calculationPaediatric dose calculation
Paediatric dose calculationHome
 

Viewers also liked (8)

Absorption
AbsorptionAbsorption
Absorption
 
Internal radiation dosimetry
Internal radiation dosimetryInternal radiation dosimetry
Internal radiation dosimetry
 
spectrophotometry, ultra violet absorption, infra red atomic absorption.
spectrophotometry, ultra violet absorption, infra red atomic absorption.spectrophotometry, ultra violet absorption, infra red atomic absorption.
spectrophotometry, ultra violet absorption, infra red atomic absorption.
 
Introduction to laboratory techniques
Introduction to laboratory techniquesIntroduction to laboratory techniques
Introduction to laboratory techniques
 
Paediatric dose calculation
Paediatric dose calculationPaediatric dose calculation
Paediatric dose calculation
 
Calculation of Doses
Calculation of DosesCalculation of Doses
Calculation of Doses
 
E sci presentation
E sci presentationE sci presentation
E sci presentation
 
Slideshare ppt
Slideshare pptSlideshare ppt
Slideshare ppt
 

Similar to Analysis of the_optical_density_profile_of_otolith_of_icefish

Optical Characterization of PV Glass Coupons and PV Modules Related to Soilin...
Optical Characterization of PV Glass Coupons and PV Modules Related to Soilin...Optical Characterization of PV Glass Coupons and PV Modules Related to Soilin...
Optical Characterization of PV Glass Coupons and PV Modules Related to Soilin...Greg Smestad
 
Application of Seismic Reflection Surveys to Detect Massive Sulphide Deposits...
Application of Seismic Reflection Surveys to Detect Massive Sulphide Deposits...Application of Seismic Reflection Surveys to Detect Massive Sulphide Deposits...
Application of Seismic Reflection Surveys to Detect Massive Sulphide Deposits...iosrjce
 
Determination ofRadiological Quality Parameters Using Optical Densitometer an...
Determination ofRadiological Quality Parameters Using Optical Densitometer an...Determination ofRadiological Quality Parameters Using Optical Densitometer an...
Determination ofRadiological Quality Parameters Using Optical Densitometer an...IOSR Journals
 
Time-resolved mirrorless scintillation detector @ AAPM2018
Time-resolved mirrorless scintillation detector @ AAPM2018Time-resolved mirrorless scintillation detector @ AAPM2018
Time-resolved mirrorless scintillation detector @ AAPM2018WonjoongCheon
 
S IGNAL A ND I MAGE P ROCESSING OF O PTICAL C OHERENCE T OMOGRAPHY AT 1310 NM...
S IGNAL A ND I MAGE P ROCESSING OF O PTICAL C OHERENCE T OMOGRAPHY AT 1310 NM...S IGNAL A ND I MAGE P ROCESSING OF O PTICAL C OHERENCE T OMOGRAPHY AT 1310 NM...
S IGNAL A ND I MAGE P ROCESSING OF O PTICAL C OHERENCE T OMOGRAPHY AT 1310 NM...sipij
 
Effects of crystal size on the imaging performance using two collimator seri...
Effects of crystal size on the imaging performance  using two collimator seri...Effects of crystal size on the imaging performance  using two collimator seri...
Effects of crystal size on the imaging performance using two collimator seri...Sin-di Lee
 
Art and medicine_columbia_2013
Art and medicine_columbia_2013Art and medicine_columbia_2013
Art and medicine_columbia_2013oriolespinal
 
Characterisation of neutron meriaty
Characterisation of neutron  meriatyCharacterisation of neutron  meriaty
Characterisation of neutron meriatyLeishman Associates
 
MEASUREMENT OF SCATTERING LOSSES OF LASER COMPONENTS BY TOTAL INTEGRATED SCAT...
MEASUREMENT OF SCATTERING LOSSES OF LASER COMPONENTS BY TOTAL INTEGRATED SCAT...MEASUREMENT OF SCATTERING LOSSES OF LASER COMPONENTS BY TOTAL INTEGRATED SCAT...
MEASUREMENT OF SCATTERING LOSSES OF LASER COMPONENTS BY TOTAL INTEGRATED SCAT...Simona Liukaityte
 
Computational Analysis Of A Thin Plate
Computational Analysis Of A Thin PlateComputational Analysis Of A Thin Plate
Computational Analysis Of A Thin PlateDavid Parker
 
A NOVEL APPROACH TO CHANNEL DECORRELATION FOR STEREO ACOUSTIC ECHO CANCELLATI...
A NOVEL APPROACH TO CHANNEL DECORRELATION FOR STEREO ACOUSTIC ECHO CANCELLATI...A NOVEL APPROACH TO CHANNEL DECORRELATION FOR STEREO ACOUSTIC ECHO CANCELLATI...
A NOVEL APPROACH TO CHANNEL DECORRELATION FOR STEREO ACOUSTIC ECHO CANCELLATI...a3labdsp
 
Dual energy imaging and digital tomosynthesis: Innovative X-ray based imaging...
Dual energy imaging and digital tomosynthesis: Innovative X-ray based imaging...Dual energy imaging and digital tomosynthesis: Innovative X-ray based imaging...
Dual energy imaging and digital tomosynthesis: Innovative X-ray based imaging...Carestream
 
APE_IM_Article_AppliedOptics_Vol47_No29_Oct10_2008_AsPublished
APE_IM_Article_AppliedOptics_Vol47_No29_Oct10_2008_AsPublishedAPE_IM_Article_AppliedOptics_Vol47_No29_Oct10_2008_AsPublished
APE_IM_Article_AppliedOptics_Vol47_No29_Oct10_2008_AsPublishedRainer Wilhelm
 
07 range measurement applications
07 range measurement applications07 range measurement applications
07 range measurement applicationsDuyen Dang
 

Similar to Analysis of the_optical_density_profile_of_otolith_of_icefish (20)

Image Processing With Sampling and Noise Filtration in Image Reconigation Pr...
Image Processing With Sampling and Noise Filtration in Image  Reconigation Pr...Image Processing With Sampling and Noise Filtration in Image  Reconigation Pr...
Image Processing With Sampling and Noise Filtration in Image Reconigation Pr...
 
1998278
19982781998278
1998278
 
Optical Characterization of PV Glass Coupons and PV Modules Related to Soilin...
Optical Characterization of PV Glass Coupons and PV Modules Related to Soilin...Optical Characterization of PV Glass Coupons and PV Modules Related to Soilin...
Optical Characterization of PV Glass Coupons and PV Modules Related to Soilin...
 
Nist talk greg_smestad_120617
Nist talk greg_smestad_120617Nist talk greg_smestad_120617
Nist talk greg_smestad_120617
 
Application of Seismic Reflection Surveys to Detect Massive Sulphide Deposits...
Application of Seismic Reflection Surveys to Detect Massive Sulphide Deposits...Application of Seismic Reflection Surveys to Detect Massive Sulphide Deposits...
Application of Seismic Reflection Surveys to Detect Massive Sulphide Deposits...
 
Determination ofRadiological Quality Parameters Using Optical Densitometer an...
Determination ofRadiological Quality Parameters Using Optical Densitometer an...Determination ofRadiological Quality Parameters Using Optical Densitometer an...
Determination ofRadiological Quality Parameters Using Optical Densitometer an...
 
Time-resolved mirrorless scintillation detector @ AAPM2018
Time-resolved mirrorless scintillation detector @ AAPM2018Time-resolved mirrorless scintillation detector @ AAPM2018
Time-resolved mirrorless scintillation detector @ AAPM2018
 
S IGNAL A ND I MAGE P ROCESSING OF O PTICAL C OHERENCE T OMOGRAPHY AT 1310 NM...
S IGNAL A ND I MAGE P ROCESSING OF O PTICAL C OHERENCE T OMOGRAPHY AT 1310 NM...S IGNAL A ND I MAGE P ROCESSING OF O PTICAL C OHERENCE T OMOGRAPHY AT 1310 NM...
S IGNAL A ND I MAGE P ROCESSING OF O PTICAL C OHERENCE T OMOGRAPHY AT 1310 NM...
 
Effects of crystal size on the imaging performance using two collimator seri...
Effects of crystal size on the imaging performance  using two collimator seri...Effects of crystal size on the imaging performance  using two collimator seri...
Effects of crystal size on the imaging performance using two collimator seri...
 
Art and medicine_columbia_2013
Art and medicine_columbia_2013Art and medicine_columbia_2013
Art and medicine_columbia_2013
 
Characterisation of neutron meriaty
Characterisation of neutron  meriatyCharacterisation of neutron  meriaty
Characterisation of neutron meriaty
 
Co33548550
Co33548550Co33548550
Co33548550
 
Co33548550
Co33548550Co33548550
Co33548550
 
MEASUREMENT OF SCATTERING LOSSES OF LASER COMPONENTS BY TOTAL INTEGRATED SCAT...
MEASUREMENT OF SCATTERING LOSSES OF LASER COMPONENTS BY TOTAL INTEGRATED SCAT...MEASUREMENT OF SCATTERING LOSSES OF LASER COMPONENTS BY TOTAL INTEGRATED SCAT...
MEASUREMENT OF SCATTERING LOSSES OF LASER COMPONENTS BY TOTAL INTEGRATED SCAT...
 
Computational Analysis Of A Thin Plate
Computational Analysis Of A Thin PlateComputational Analysis Of A Thin Plate
Computational Analysis Of A Thin Plate
 
A NOVEL APPROACH TO CHANNEL DECORRELATION FOR STEREO ACOUSTIC ECHO CANCELLATI...
A NOVEL APPROACH TO CHANNEL DECORRELATION FOR STEREO ACOUSTIC ECHO CANCELLATI...A NOVEL APPROACH TO CHANNEL DECORRELATION FOR STEREO ACOUSTIC ECHO CANCELLATI...
A NOVEL APPROACH TO CHANNEL DECORRELATION FOR STEREO ACOUSTIC ECHO CANCELLATI...
 
Dual energy imaging and digital tomosynthesis: Innovative X-ray based imaging...
Dual energy imaging and digital tomosynthesis: Innovative X-ray based imaging...Dual energy imaging and digital tomosynthesis: Innovative X-ray based imaging...
Dual energy imaging and digital tomosynthesis: Innovative X-ray based imaging...
 
APE_IM_Article_AppliedOptics_Vol47_No29_Oct10_2008_AsPublished
APE_IM_Article_AppliedOptics_Vol47_No29_Oct10_2008_AsPublishedAPE_IM_Article_AppliedOptics_Vol47_No29_Oct10_2008_AsPublished
APE_IM_Article_AppliedOptics_Vol47_No29_Oct10_2008_AsPublished
 
07 range measurement applications
07 range measurement applications07 range measurement applications
07 range measurement applications
 
Freznal zone
Freznal zoneFreznal zone
Freznal zone
 

More from ryszardtraczyk

More from ryszardtraczyk (17)

Age of sgi_short
Age of sgi_shortAge of sgi_short
Age of sgi_short
 
O s icefish
O s icefishO s icefish
O s icefish
 
Otolith shape icefish
Otolith shape icefishOtolith shape icefish
Otolith shape icefish
 
Ace cal c
Ace cal cAce cal c
Ace cal c
 
Materiały wyniki
Materiały wyniki Materiały wyniki
Materiały wyniki
 
Ps.georgianus druk
Ps.georgianus drukPs.georgianus druk
Ps.georgianus druk
 
Otolith shape
Otolith shapeOtolith shape
Otolith shape
 
Zagadki ryb antarktycznych
Zagadki ryb antarktycznychZagadki ryb antarktycznych
Zagadki ryb antarktycznych
 
Implementacja gcos pl
Implementacja gcos plImplementacja gcos pl
Implementacja gcos pl
 
Dioksyny szkodliwość
Dioksyny szkodliwośćDioksyny szkodliwość
Dioksyny szkodliwość
 
Migration ps.georgianus
Migration ps.georgianusMigration ps.georgianus
Migration ps.georgianus
 
Antarctica fish mercury
Antarctica fish mercuryAntarctica fish mercury
Antarctica fish mercury
 
Z rzeki do oceanu esej
Z rzeki do oceanu esejZ rzeki do oceanu esej
Z rzeki do oceanu esej
 
Anarchia dryf kontyn_ryby_antarkty_notatki
Anarchia dryf kontyn_ryby_antarkty_notatkiAnarchia dryf kontyn_ryby_antarkty_notatki
Anarchia dryf kontyn_ryby_antarkty_notatki
 
Bractwo żeglarskie historia
Bractwo żeglarskie historiaBractwo żeglarskie historia
Bractwo żeglarskie historia
 
Statki druk 05-06-2014
Statki druk 05-06-2014Statki druk 05-06-2014
Statki druk 05-06-2014
 
Hatch fitting short_new_1
Hatch fitting short_new_1Hatch fitting short_new_1
Hatch fitting short_new_1
 

Recently uploaded

Determination of antibacterial activity of various broad spectrum antibiotics...
Determination of antibacterial activity of various broad spectrum antibiotics...Determination of antibacterial activity of various broad spectrum antibiotics...
Determination of antibacterial activity of various broad spectrum antibiotics...Open Access Research Paper
 
VIP Call Girls Moti Ganpur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
VIP Call Girls Moti Ganpur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...VIP Call Girls Moti Ganpur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
VIP Call Girls Moti Ganpur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...Suhani Kapoor
 
VIP Call Girls Saharanpur Aaradhya 8250192130 Independent Escort Service Saha...
VIP Call Girls Saharanpur Aaradhya 8250192130 Independent Escort Service Saha...VIP Call Girls Saharanpur Aaradhya 8250192130 Independent Escort Service Saha...
VIP Call Girls Saharanpur Aaradhya 8250192130 Independent Escort Service Saha...Suhani Kapoor
 
VIP Call Girls Mahadevpur Colony ( Hyderabad ) Phone 8250192130 | ₹5k To 25k ...
VIP Call Girls Mahadevpur Colony ( Hyderabad ) Phone 8250192130 | ₹5k To 25k ...VIP Call Girls Mahadevpur Colony ( Hyderabad ) Phone 8250192130 | ₹5k To 25k ...
VIP Call Girls Mahadevpur Colony ( Hyderabad ) Phone 8250192130 | ₹5k To 25k ...Suhani Kapoor
 
Mumbai Call Girls, 💞 Prity 9892124323, Navi Mumbai Call girls
Mumbai Call Girls, 💞  Prity 9892124323, Navi Mumbai Call girlsMumbai Call Girls, 💞  Prity 9892124323, Navi Mumbai Call girls
Mumbai Call Girls, 💞 Prity 9892124323, Navi Mumbai Call girlsPooja Nehwal
 
VIP Call Girls Ramanthapur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
VIP Call Girls Ramanthapur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...VIP Call Girls Ramanthapur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
VIP Call Girls Ramanthapur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...Suhani Kapoor
 
Environmental Management System - ISO 14001:2015-
Environmental Management System      - ISO 14001:2015-Environmental Management System      - ISO 14001:2015-
Environmental Management System - ISO 14001:2015-Kawther MEKNI
 
VIP Call Girls Service Chaitanyapuri Hyderabad Call +91-8250192130
VIP Call Girls Service Chaitanyapuri Hyderabad Call +91-8250192130VIP Call Girls Service Chaitanyapuri Hyderabad Call +91-8250192130
VIP Call Girls Service Chaitanyapuri Hyderabad Call +91-8250192130Suhani Kapoor
 
Russian Call Girls Nashik Anjali 7001305949 Independent Escort Service Nashik
Russian Call Girls Nashik Anjali 7001305949 Independent Escort Service NashikRussian Call Girls Nashik Anjali 7001305949 Independent Escort Service Nashik
Russian Call Girls Nashik Anjali 7001305949 Independent Escort Service Nashikranjana rawat
 
Freegle User Survey as visual display - BH
Freegle User Survey as visual display - BHFreegle User Survey as visual display - BH
Freegle User Survey as visual display - BHbill846304
 
webinaire-green-mirror-episode-2-Smart contracts and virtual purchase agreeme...
webinaire-green-mirror-episode-2-Smart contracts and virtual purchase agreeme...webinaire-green-mirror-episode-2-Smart contracts and virtual purchase agreeme...
webinaire-green-mirror-episode-2-Smart contracts and virtual purchase agreeme...Cluster TWEED
 
办理学位证(KU证书)堪萨斯大学毕业证成绩单原版一比一
办理学位证(KU证书)堪萨斯大学毕业证成绩单原版一比一办理学位证(KU证书)堪萨斯大学毕业证成绩单原版一比一
办理学位证(KU证书)堪萨斯大学毕业证成绩单原版一比一F dds
 
(ANIKA) Call Girls Wagholi ( 7001035870 ) HI-Fi Pune Escorts Service
(ANIKA) Call Girls Wagholi ( 7001035870 ) HI-Fi Pune Escorts Service(ANIKA) Call Girls Wagholi ( 7001035870 ) HI-Fi Pune Escorts Service
(ANIKA) Call Girls Wagholi ( 7001035870 ) HI-Fi Pune Escorts Serviceranjana rawat
 
Call Girls Ahmedabad 7397865700 Ridhima Hire Me Full Night
Call Girls Ahmedabad 7397865700 Ridhima Hire Me Full NightCall Girls Ahmedabad 7397865700 Ridhima Hire Me Full Night
Call Girls Ahmedabad 7397865700 Ridhima Hire Me Full Nightssuser7cb4ff
 
Air pollution soli pollution water pollution noise pollution land pollution
Air pollution soli pollution water pollution noise pollution land pollutionAir pollution soli pollution water pollution noise pollution land pollution
Air pollution soli pollution water pollution noise pollution land pollutionrgxv72jrgc
 

Recently uploaded (20)

Determination of antibacterial activity of various broad spectrum antibiotics...
Determination of antibacterial activity of various broad spectrum antibiotics...Determination of antibacterial activity of various broad spectrum antibiotics...
Determination of antibacterial activity of various broad spectrum antibiotics...
 
VIP Call Girls Moti Ganpur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
VIP Call Girls Moti Ganpur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...VIP Call Girls Moti Ganpur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
VIP Call Girls Moti Ganpur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
 
VIP Call Girls Saharanpur Aaradhya 8250192130 Independent Escort Service Saha...
VIP Call Girls Saharanpur Aaradhya 8250192130 Independent Escort Service Saha...VIP Call Girls Saharanpur Aaradhya 8250192130 Independent Escort Service Saha...
VIP Call Girls Saharanpur Aaradhya 8250192130 Independent Escort Service Saha...
 
VIP Call Girls Mahadevpur Colony ( Hyderabad ) Phone 8250192130 | ₹5k To 25k ...
VIP Call Girls Mahadevpur Colony ( Hyderabad ) Phone 8250192130 | ₹5k To 25k ...VIP Call Girls Mahadevpur Colony ( Hyderabad ) Phone 8250192130 | ₹5k To 25k ...
VIP Call Girls Mahadevpur Colony ( Hyderabad ) Phone 8250192130 | ₹5k To 25k ...
 
Mumbai Call Girls, 💞 Prity 9892124323, Navi Mumbai Call girls
Mumbai Call Girls, 💞  Prity 9892124323, Navi Mumbai Call girlsMumbai Call Girls, 💞  Prity 9892124323, Navi Mumbai Call girls
Mumbai Call Girls, 💞 Prity 9892124323, Navi Mumbai Call girls
 
VIP Call Girls Ramanthapur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
VIP Call Girls Ramanthapur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...VIP Call Girls Ramanthapur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
VIP Call Girls Ramanthapur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
 
Environmental Management System - ISO 14001:2015-
Environmental Management System      - ISO 14001:2015-Environmental Management System      - ISO 14001:2015-
Environmental Management System - ISO 14001:2015-
 
VIP Call Girls Service Chaitanyapuri Hyderabad Call +91-8250192130
VIP Call Girls Service Chaitanyapuri Hyderabad Call +91-8250192130VIP Call Girls Service Chaitanyapuri Hyderabad Call +91-8250192130
VIP Call Girls Service Chaitanyapuri Hyderabad Call +91-8250192130
 
Gandhi Nagar (Delhi) 9953330565 Escorts, Call Girls Services
Gandhi Nagar (Delhi) 9953330565 Escorts, Call Girls ServicesGandhi Nagar (Delhi) 9953330565 Escorts, Call Girls Services
Gandhi Nagar (Delhi) 9953330565 Escorts, Call Girls Services
 
Russian Call Girls Nashik Anjali 7001305949 Independent Escort Service Nashik
Russian Call Girls Nashik Anjali 7001305949 Independent Escort Service NashikRussian Call Girls Nashik Anjali 7001305949 Independent Escort Service Nashik
Russian Call Girls Nashik Anjali 7001305949 Independent Escort Service Nashik
 
Call Girls In R.K. Puram 9953056974 Escorts ServiCe In Delhi Ncr
Call Girls In R.K. Puram 9953056974 Escorts ServiCe In Delhi NcrCall Girls In R.K. Puram 9953056974 Escorts ServiCe In Delhi Ncr
Call Girls In R.K. Puram 9953056974 Escorts ServiCe In Delhi Ncr
 
FULL ENJOY Call Girls In kashmiri gate (Delhi) Call Us 9953056974
FULL ENJOY Call Girls In  kashmiri gate (Delhi) Call Us 9953056974FULL ENJOY Call Girls In  kashmiri gate (Delhi) Call Us 9953056974
FULL ENJOY Call Girls In kashmiri gate (Delhi) Call Us 9953056974
 
Freegle User Survey as visual display - BH
Freegle User Survey as visual display - BHFreegle User Survey as visual display - BH
Freegle User Survey as visual display - BH
 
Sexy Call Girls Patel Nagar New Delhi +918448380779 Call Girls Service in Del...
Sexy Call Girls Patel Nagar New Delhi +918448380779 Call Girls Service in Del...Sexy Call Girls Patel Nagar New Delhi +918448380779 Call Girls Service in Del...
Sexy Call Girls Patel Nagar New Delhi +918448380779 Call Girls Service in Del...
 
webinaire-green-mirror-episode-2-Smart contracts and virtual purchase agreeme...
webinaire-green-mirror-episode-2-Smart contracts and virtual purchase agreeme...webinaire-green-mirror-episode-2-Smart contracts and virtual purchase agreeme...
webinaire-green-mirror-episode-2-Smart contracts and virtual purchase agreeme...
 
办理学位证(KU证书)堪萨斯大学毕业证成绩单原版一比一
办理学位证(KU证书)堪萨斯大学毕业证成绩单原版一比一办理学位证(KU证书)堪萨斯大学毕业证成绩单原版一比一
办理学位证(KU证书)堪萨斯大学毕业证成绩单原版一比一
 
E Waste Management
E Waste ManagementE Waste Management
E Waste Management
 
(ANIKA) Call Girls Wagholi ( 7001035870 ) HI-Fi Pune Escorts Service
(ANIKA) Call Girls Wagholi ( 7001035870 ) HI-Fi Pune Escorts Service(ANIKA) Call Girls Wagholi ( 7001035870 ) HI-Fi Pune Escorts Service
(ANIKA) Call Girls Wagholi ( 7001035870 ) HI-Fi Pune Escorts Service
 
Call Girls Ahmedabad 7397865700 Ridhima Hire Me Full Night
Call Girls Ahmedabad 7397865700 Ridhima Hire Me Full NightCall Girls Ahmedabad 7397865700 Ridhima Hire Me Full Night
Call Girls Ahmedabad 7397865700 Ridhima Hire Me Full Night
 
Air pollution soli pollution water pollution noise pollution land pollution
Air pollution soli pollution water pollution noise pollution land pollutionAir pollution soli pollution water pollution noise pollution land pollution
Air pollution soli pollution water pollution noise pollution land pollution
 

Analysis of the_optical_density_profile_of_otolith_of_icefish

  • 1. Measurement and analysis of optical density profiles of otolith from Ps. georgianus and Ch. gunnarii. Ryszard Traczyk Introduction. Analysis of cross-sections and whole otoliths, for their growth poses many difficulties, it is very tedious and time consuming. Results of analyzes are very different, largely depends on the method used, the individual researcher's experience, as well as his physical and mental abilities: visual acuity of vision - the distinction of color, degree of fatigue, or memory of experiments in the large number of observations and measurements derived under the microscope. There are only stored information which are research purpose, additional are lost. In this paper, a variety of investigation and measurement of otolith increments were performed by computer measurement and harmonic analysis of the optical density - daily and other otoliths increments are repeated several times at intervals of time and space. The peaks of optical density of daily increments in otoliths mackerel icefish were more suppressed by noise records than South Georgia icefish. Ch. gunnarii is a pelagic fish, where there are more noises and Ps. georgianus is more demersal, where its gets less noises. Statistical significance for power of daily increments peaks was tested. For nuclei of larval otoliths of Pseudochaenichthys georgianus average width of daily increments was 9.41 * 10-4 mm. Width of daily otolith increments for juvenile of Champsocephalus gunnarii were 0.0024 mm. Cyclical increments in larval otoliths of Ps. georgianus proceeded by a sine wave: y=3,42sin( x[mm] -0,08)+235,1, and for juvenile of Ch. gunnarii by a sine wave: y=3,82sin( x[mm] -24,83)+90. Materials and Methods. Measurements of optical density of otolith increments were carried out from digital photos of otolith slices, obtained by the excision of otoliths, two-sided grinding, polishing and etching with EDTA (1). Optical density measurements were performed in the program "Fiji image" developed for visualization and measurements of microscope images (2). The otolith material were collected during research cruises on the RV. "Professor Siedlecki" (3; 1). The images were processed to measurements: contrast was optimized, background was cleared, the SI mm unit was setup. For each change its optical density profile were recorded with 1231 measurements along otoliths radius and stored. Further study were on pictures with background evenly to dark. Exploration and study of cyclic variation of optical density of increments otoliths were carried out three ways: 1) Spectral analysis and REDFIT procedures of statistical package PAST (4; 5), utilizing Fourier transformation algorithm of Lomb’s periodogram (6; 7; 8; 9); 2) the procedure for the fitting sinusoid to the empirical data using program PAST. 3) minimizing the sum of squares of model deviations from the empirical data using Excel Solver tool.
  • 2. Fig. 1. Image processing, contrast optimization, extraction and reset the background. In the model REDFIT the procedure to increase the number of points on the frequency axis was used (5) - after passing the series test fitting empirical data to red noise model (5). Average cycle of daily increments was determined by moving a series of measurements (713 for Ps. georgianus and 503 for Ch. gunnarii) of the optical density along whole density profile of the same otolith radius (which retains a fixed number for subtracted value) and determining the first minimum in sums of squared differences of optical density in the adjacent of each measure of series. The distance in moving from the initial difference of none (0 - subtract the same value) to the first minimum was adopted for the period: 24 h periodicity unit. A series of 713 measurements were selected from the optical density profile of otolith of Ps. georgianus starting from measure No 7 from the edge nucleus to the 720 measure along the radius – because measurements began not exactly from the edge, but before it and additionally the initial marginal, usually unclear measurements should be excluded from the analysis of the pattern. Fig. 2. Measuring the density of the image having background aligned. Determination of the period between troughs. In column D is the subtraction of series after its first shifts (subtraction without any move produces a sum of squared difference equal to 0). Subtraction series after its 16 time shift resulted in second column of S giving minimum sum of squared differences. In further columns that sums grow. The blue line - series of 1231 optical density measurements, green - 713 initial measurements from 7 to 720 measurement that were subject to move with one unit measurement: every 0.000059 mm. A series of 503 measurements of the otolith optical density of Ch. gunnarii, were selected from its profile on radius from 507 measure from the edge to the 1009 measure.
  • 3. Fig. 3. Profile of the optical density of otolith nuclei of Ch. gunnarii (r = 0.04 mm), with reset the background. Fig. 4. Profile of the optical density extended outside of otolith nucleus of Ch. gunnarii (r = 0.22 mm), with reset the background.
  • 4. Fig. 5. Profile of the optical density for cross section of otolith of Ch. gunnarii (r = 0.44 mm), with reset the background. Fig. 6. Measurement of the optical density of the images having reduced background. Determination of the period between troughs. Column D contain results of the subtraction of series after its first shifts. Subtraction series after the moving of one of two with about six units resulted in second minimum sum of squared differences placed in column I. Shift by next six unit gave third minimum Sum in column N. Shift by next six unit gave minimum No 4. The blue line - series of 1615 optical density measurements, green - middle 503 measurements from 507 to 1009, that were moved with unit: the distance between measurement equal to 0.0004 mm. Shifts of large series of measurements form a representative unit of daily increment.
  • 5. Results Pseudochaenichthys georgianus. The average period of diurnal cycling in the increments specified by relative displacement of 713 measurements became 9.41 * 10-4 mm = 941 nm. Harmonic analysis Lomb-Scargl in the program PAST indicated the presence in the otolith increments two statistically significant periodicity: daily and 8-daily. A large portion of the variability of the analyzed record still have the transformations above daily periodicity in the echo effects: peak No 3 of 5 daily cycle, and peaks No 4 and 5 of circadian cycles. Fig. 7. Participation sinusoids in the variability of density record. The dotted and dashed lines define the probability levels for which the harmonics included there in the part of the noise generated by it. Peaks 1-5 with a power above the level of 11.87, with a frequency of 0.0075 cycles / 60 nm, have a probability close to 0, which is equal to and less 0.01, which means that in the analyzed series of space - time there are exists cyclicality with such frequencies. Other harmonics have a smaller share of variability and can be a large percentage of noise - are generated randomly by the noise. However, in the procedure fit profile to tested the red noise model (used to analyze the signals common in the the marine environment), MonteCarlo simulation test 99% show that in the analyzed variation can not be identified significantly strong periodicity, which would not have been generated by incidental noise, beyond the peak four-hour cycle. The use this model here is appropriate, as indicated by series test. Fig. 8. Spectral analysis of the optical density of otolith increments for fitting spectrum data to the red noise model (5). Because at test, fitting sample to the model, the number of runs 171 has been set at 5% confidence interval of: 161-198, the above noise model is appropriate for the tested series, which contains not a strong periodicities. Plot of curves of χ² and Monte Carlo for studies of statistical significance of power of peaks. Calculate the critical level indicator (False-al.) the probability of random creation of a sine wave: here in 99.86% a sine wave is generated by noise -enters into its composition. As it was small sample for above procedure, the number of points on the frequency axis 0 2 4 6 8 10 12 14 16 18 20 22 24 26 0 0,1 0,2 0,3 0,4 0,5 p(random) = 0,000000009961 moc~A2 poziom 0,01 = 11,87 poziom 0,05 = 10,24 frequency Peak1 f= 0,007528 cycles per 59 nm, or per 1,5 h; 0,0078 mm/cycle, or 8 days/cycle Peak3 f = 0,013305 cycles per 59 nm, or per1,5 h; 0,0044 mm/cycle, or 5 days/cycle Peak5 f = 0,05007 cycles per 59 nm, or per 1,5 h; 0,001 mm/cycle, or 1,25 day/cycle Peak4 f = 0,051996 cycles per 59 nm, or per 1,5 h; 0,001 mm/cycle, or 1,2 day/cycle Peak2 f = 0,0649 cycles per 59 nm, or per 1,5 h; 0,001 mm/cycle, or 1 day/cycle power ~A² level 0.01=11.87 level 0.05=10.24 0 1000 2000 3000 4000 5000 6000 7000 0 0,1 0,2 0,3 0,4 0,5 τ: 2,2696, Bnwith: 0,001692, False-al.: 99,86 moc chi2 99% chi2 95% Teoret.AR(1) Monte Carlo 95% Monte Carlo 99% krytycz. Chi2 frequency Peak1 f = 0,00699 cycle per 59 nm, or per 1,5 h.; 0,0084 mm/cycle, or 9 days/cycle Runs Test: k=171 is in 5% aceptance interval: 161-198. Peak3 f =0,039 cycle per 59 nm, or per 1,5 h.; 0,002 mm/cycle, or 1,6 day/cycle Pea4 f=0.05175 cycle per 59 nm, or per 1.5 h.; 0.001 mm/cycle, or 1.2 day/cycle Peak5 f=0.064336 cycle per 59 nm, or per1.5 h.; 0.0009 mm/cycle, or 1 day/cycle Peak2 f=0.2112 cycle per 59 nm, or per 1.5 h.; 0.0003 mm/cycle, or 7 h./cycle Peak6 f=0.35524 cycle per 59 nm, or per 1,5 h 0.00017 mm/cycle, or 4 h./cykl power 99%χ² 95%χ² Theoret. AR(1) 99%Monte Carlo 95%Monte Carlo Crit.level χ²
  • 6. was doubled that give periodicity considerably strong. 0 1000 2000 3000 4000 5000 6000 7000 0 0,01 0,02 0,03 0,04 0,05 0,06 0,07 0,08 0,09 0,1 Moc χ² 99% χ² 95% Teoret.AR(1) frekw Pik1 f =0,0073427 cykli na 59 nm, lub w 1,5 godz., a to jest 0,008 mm/cykl, lub 8,5 doby/cykl Pik3 f =0,013287 cykli na 59 nm, lub w 1,5 godz., a to jest 0,0044 mm/cykl, lub 4,7 doby/cykl Pik5 f =0,05 cykli na 59 nm, lub w 1,5 godz., a to jest 0,001 mm/cykl, lub 1,3 doby/cykl Pik4 f =0,052098 cykli na 59 nm, lub w 1,5 godz., a to jest 0,001 mm/cykl, lub 1,2 Pik2 f =0,065035 cykli na 59 nm, lub w 1,5 godz., a to jest 0,001 mm/cykl, lub 1 doba/cykl Pik7 f =0,01958 cykli na 59 nm, lub w 1,5 godz., a to jest 0,003 mm/cykl, lub 3,2 doby/cykl Pik6 f =0,039161 cykli na 59 nm, lub w 1,5 godz., a to jest 0,0015 mm/cykl, lub 1,6 Fig. 9. By increasing the number of points on the frequency axis, two considerably periodicity in otolith increments, were underlined (by 99%χ²): 8.5 diurnal cycle and 1 daily. Less significant (under 99%, overgrove 95% Monte Carlo) were circadian cycles. The variability of otolith increments have a large share of periodicity of 5, 3 and 2 daily cycles - transformations from one to more daily cycles in echo effects (7). Symbols as in above figure. Sinusoidal curve fitting. The first seven sinusoids (y=Ansin( x + φn)+const.) matched to empirical measurement of optical density well explains the variation of the optical density of otolith increments. Two sine waves in the first look dominate: one daily and 8 daily cycle, as in the spectral analysis. Parameters derived: amplitude - A period - T phase - φ, were similar to those measured with known periods in spectral analysis, Tab. 1. Fig. 103 Fitting empirical 713 measurements by model composed of seven sinusoids.. Most closely fitted course of the 7 main sinusoids, were determined by optimizing all 22 parameters to minimizing the sum of squared deviations of the model, yi from empirical data, ye. This sum amounted to min|Σ(yi-ye)2|=72257,5. Such estimates for previous methods were higher. As a result calculation of the third method it was obtained that the strength of periodicity (proportional to A2) comes from two main cycles: the first 8 daily cycle A1 = 4.52 (T1 = 0.00789 mm, φ1 = -2.64) and the second daily cycle, A2 = 3.42 (T2 = 0.00091 mm, φ2 = -0.08. Constans = 235.1. Variability in optical density of the otolith, still explain the circadian sinusoid: 1.2 of daily 180 190 200 210 220 230 240 250 260 0 0,01 0,02 0,03 0,04 nucleus edge gęst. optyczna fragmentu promienia jądra, N = 713 pomiarów y dopasowane, nieznane A, T, φ: mm unknown A, T, φ: A 1=4,51, φ1=-2,41, T1=0,007955; A2=3,49, φ2=-0,566, T2=0,000908; A3=3,19, φ3=-3,11, T3=0,004395; A4=3,28, φ4=1,1, T4=0,001124; A5=2,96, φ5=-2,98, T5=0,001495; A6=2,77, φ6=-1,68, T6=0,002959; A7=2,7, φ7=2,8, T7=0,002111; stała =235,1 χ² = 72951; R² = 0,27408; p = 1,7577E-42; Akaike IC = 72979; Σ(yₑ-yₓ)²=72951; Σ(yₓ-yₓ)²=5837 optical density of nucleus radius, N=713 measurements y fitted, unknown A, T, φ
  • 7. cycle A4 = 6.07 (T4 = 0.00114 mm, φ4 = 0.81) and 1.3 of daily cycle: A5 = 5.33 (T5 = 0.00115 mm, φ5 = -2.87). 3 cycles of other incorporated into the model are likely to be interpreted as transformation of the first – daily cycle in echo effect: 5 daily with A3 = 3.31 (T3 = 0.00446 mm, φ3 = 3.11), 3 daily with A7 = 2.79 (T7 = 0 , 00299 mm, φ7 = -3.21) and 2 daily A6 = 3.11 (T6 = 0.0015 mm, φ6 = 3.89). Existence of harmonic component with a frequency of daily increment determines the frequencies of multiple components: the effects of jumps in periods of 2 *, 3 *, 4 * daily, etc. Tab. 1. Sinusoids parameters (Ps. georgianus larvae), daily increments in bold. From spectral analysis of PAST. From fitting sinusoids of PAST. From minimizing the sum of squared deviations No A φ T Const. A φ T Const. A φ T Const. 1 Sin 4,47 -2,53 0,008011 235,1 4,51 -2,41 0,007955 235,1 4,5153 -2,6358 0,007892 235,1 2 Sin 3,39 -0,0911 0,000905 χ² 3,49 -0,566 0,000908 χ² 3,4242 -0,082 0,000906 3 Cos 3,29 2,95 0,004427 73979 3,19 -3,11 0,004395 72951 3,3089 3,1087 0,004461 4 Sin 2,88 0,516 0,001129 R² 3,28 1,1 0,001124 R² 6,0728 0,8111 0,001141 5 Cos 2,36 -1,5 0,001177 0,26384 2,96 -2,98 0,001495 0,27408 5,3267 -2,8712 0,001154 6 Sin 2,97 2,97 0,0015 P 2,77 -1,68 0,003 p 3,1081 3,8871 0,001504 7 sin 2,71 -2,44 0,003004 2,3727E-40 2,7 2,8 0,002111 1,7577E-42 2,7912 -3,2104 0,002986 Fig. 11. The results of measurements approximated by model consisting of seven sinusoids with the use Excel Solver tool - it's hard to count them. The increments pattern have changes, one just 0,027 mm from the edge of the otolith nucleus. Fig. 12. The base periodicity: unite of daily increments with nine daily - number of them along nucleus radius. 180 190 200 210 220 230 240 250 260 0 0,01 0,02 0,03 0,04 nucleus edge gęst. optyczna fragmentu promienia jądra, N = 713 pomiarów solver Σ1-7(An*sin(2πx/Tn+φn))+const. mm solver: A1=4,52, φ1=-2,64, T1=0,00789; A2=3,42, φ2=-0,08, T2=0,00091; A3=3,31, φ3=3,11, T3=0,00446; A4=6,07, φ4=0,81, T4=0,00114; A5=5,33, φ5=-2,87, T5=0,00115; A6=3,11, φ6=3,89, T6=0,0015; A7=2,79, φ7=-3,21, T7=0,00299; stała =235,1 Σ(yₑ-yₓ)²=72257,5 optical density of nucleus radius, N=713 measurements solver tool Σ1-7(An*sin(2πx/Tn+φn))+const. 225 235 245 0 0,01 0,02 0,03 0,04 nucleus edge Σ1,2(Asin(2πx/T +φ))+cons mm A1=4,52, φ1=-2,64 T1=0,00789; A2=3,42, φ2=-0,08, T2=0,00091; stała =235,1
  • 8. Fig. 13. Sinusoidal components: the daily cycle and circadian, their increments number in the section of nucleus radius of otolith - they overlap (they can be passing at the same layer on the joint surface goes in negative and positive curvatures). Fig. 14. Sinusoidal components: multiple echo effects (reflections from the parallel walls): several daily cycles - their increments number in the section of nucleus radius of otolith. Mixing the direct signal with the reflected - delayed signal. In otolith sound speed is 3.5 times higher than in the endolymph. Adding to model the four-hour periodicity, y6=0,37sin( x[mm] +4,82)+235,1 , Fig. 8, increases the fit of the model (increases the amplitude of circadian growth). But no eliminates changes in the formula growth – f.e. abnormal one at 0.027 mm distance from the nucleus edge, Fig. 11. These optical density profiles of otolith nuclei of Ps. georgianus larvae complement previously presented otolith profiles of optical density and widths of daily increments for juvenes and adults this species (1): 0.00091 mm for larvae; 0.00284 mm for juvenes; 0.0034 mm for adults. Champsocephalus gunnarii. Moving the 503 measurements of increments periodicity in relation to adjacent otolith increments determined the average daily otolith growth for larvae of Ch. gunnarii amounting to 0.0024 mm. Average daily increments of this width in the measured radius otolith equals to 0.43 mm can be 180. Harmonic analysis Lomb-Scargl’s, did not give the results of such a strong periodicity for these daily increments. They were drowned out by large number of strong signals with periods of 0.03 mm. 227 229 231 233 235 237 239 241 0 0,01 0,02 0,03 0,04 nucleus edge y2=3,39sin(2πx/0,001+-0,08)+235,1 y4=6,84sin(2πx/0,001+0,85)+235,1 y5=6,1cos(2πx/0,001+-2,98)+235,1 mm A2=3,42, φ2=-0,08, T2=0,00091; A4=6,07, φ4=0,81, T4=0,00114; A5=5,33, φ5=-2,87, T5=0,00115; const. =235,1 231 233 235 237 239 0 0,01 0,02 0,03 0,04 nucleus edge y3=3,36cos(2πx/0,004+3,02)+235,1 y6=3,06sin(2πx/0,002+4,01)+235,1 y7=2,05sin(2πx/0,003+-1,41)+235,1 A3=3,31, φ3=3,11, T3=0,00446; A6=3,11, φ6=3,89, T6=0,0015; A7=2,79, φ7=-3,21, T7=0,00299; const. =235,1 mm
  • 9. Fig. 15. Decomposition of spatial periodicity of optical density of otoliths for sinus and cosine components. Meaning of symbols as in Fig. 7. Diurnal periodicity in the optical density profile of otoliths Ch. gunnarii really stand Redfit model for red noise. Because the measurement range is large in relation to the growth cycles, it was partitioned into 3 equal segments for averaging the resulting spectrum, which reduces the noise (4). In the model, the number of points on the frequency axis is concentrated twice. Despite negative a runs test for fit to the red-noise model, it was used to investigate the statistical significance of the component peaks. Simulations 99% of Monte Carlo model showed that there are only two significant spectral peaks: daily and 54 daily increments. These sinusoids over goes 99.88% False-alarm level, which includes probability of random to be generated by noise, Fig. 16. Fig. 16. The spectrum of sinusoids in red noise model REDFIT. A. Meaning of symbols as in Fig. 8. 0 10 20 30 40 50 60 70 80 90 100 110 120 0 0,01 0,02 0,03 0,04 0,05 0,06 0,07 0,08 0,09 0,1 0,11 0,12 0,13 0,14 0,15 0,16 0,17 0,18 0,19 0,2 p(random) = 1,396E-47 Moc ~A² Theor.AR(1) poziom 0,01 = 12,29 poziom 0,05 = 10,65 Frequency Peak1 f =0.0030998 cycle per 0.0004 mm, or per 4 h., 0.129 mm/cycle, or 54 days/cycle Peak2 f =0.00077495 cycle per 0.0004 mm, or per 4 h., 0.52 mm/cycle, or 215 days/cycle Peak3 f =0.0023249 cycle per 0.0004 mm, or per 4 h. 0.172 mm/cycle, lub 72 days/cycle Peak4 f =0.0015499 cycle per 0.0004 mm, or per 4 h. 0.258 mm/cycle, or 108 days/cycle Peak5 f =0.0080595 cycle per 0.0004 mm, or per 4 h. 0.05 mm/cycle, or 21 days/cycle Peak6 f =0.012477 cycle per 0.0004 mm, or per 4 h. 0.032 mm/cycle, or 13 days/cycle Peak7 f =0.014492 cycle per 0,0004 mm, or per 4 h. 0.028 mm/cycle, or 12 days/cycle Peak8 f =0.023869 cycle per 0.0004 mm, or per 4 h. 0.017 mm/cycle, or 7 days/cycle Peak12 f =0.16669 cycle per 0.0004 mm, or per 4 h. 0.002 mm/cycle, or 1 day/cycle Peak11 f =0.11268 cycle per 0.0004 mm, or per 4 h.; 0.004 mm/cycle, or 1 day/cycle Peak10 f =0.08943 cycle per 0.0004 mm, or per 4 h. 0.0045 mm/cycle, or 2 days/cykl Peak9 f =0.054324 cycle per 0.0004 mm, or per 4 h. 0.007 mm/cycle, or 3 days/cycle power ~A² Theor. AR(1) level 0.01=12.29 level 0.05=10.65 9 10 6 5 3 4 8 2 7 1 0 20000 40000 60000 80000 100000 120000 140000 160000 180000 200000 0 0,01 0,02 0,03 0,04 0,05 0,06 0,07 0,08 0,09 0,1 0,11 0,12 0,13 0,14 0,15 0,16 0,17 0,18 0,19 0,2 0,21 0,22 Moc ~A² 95%χ² 99%χ² kryt.χ² 95%M.Carlo 99%M.Carlo Teor.AR(1) Frequency Peak₃ f =0.16667 cycle per 0.0004 mm, or per 4 h.; 0.0024 mm/cycle, or 1 d./cycle; Peak₄ f =0.17162 cycle per 0.0004 mm, or per 4 h.; 0,002 mm/cycle, or 1 d./cycle; Peak₅ f =0.11276 cycle per 0.0004 mm, or per 4 h.; 0.003547 mm/cycle, or 1 day/cycle Peak₆ f =0.089219 cycle per 0.0004 mm, or per 4 h.; 0.004483 mm/cycle, or 2 days/cycle; Peak₇ f =0.21747 cycle per 0.0004 mm, or per 4 h.; 0.002 mm/cycle, or 1 day/cycle; Peak₈ f =0.18401 cycle per 0.0004 mm, or per 4 h.; 0.002 mm/cycle, or 1 day/cycle; Peak₉ f =0.0080545 cycle per 0.0004 mm, or per 4 h.; 0.05 mm/cycle, or 21 days/cycle; Peak₁₀ f =0.012392 cycle per 0.0004 mm, or per 4 h.; 0.0323 mm/cycle, lub 13 days/cycle; Peak₁ f =0.0030979 cycle per 0.0004 mm, or per 4 h.; 0,129 mm/cycle, or 54 d./cycle; Peak₂ f =0.20694 cycle per 0.0004 mm, or per 4 h.; 0.002 mm/cycle, or 0.8 day/cycle, τ: 7,0239, Bnwith: 0,001499, False-alarm: 99,88; oversample: 2; segments: 3 p(random) = 5,96E-48; Runs test for fit to the red noise model: k=348 is outside 5% acceptance interval: 379-431. strong periodic components. power ~A² 95%χ² 99%χ² Crit.level χ² 95%Monte Carlo 99%Monte Carlo Theoret. AR(1)
  • 10. Fig. 17. The spectrum of sinusoids in red noise model REDFIT. B. Meaning of symbols as in Fig. 8. Obtained above the frequency of daily increments, being the subject of studies, provide data about the period of this process, which is a cyclic record of periodic signals that cause cyclical changes in component concentrations and pressure of endolymph. The peak frequency of daily increments from research reached 0.16667 cycles per unit - per 0.0004 mm, intervals of which measurement was performed. Hence one cycle - the daily growth period of otolith Ch. gunnarii is 0.0024 mm. Thus obtained periods of other peaks were used to determine the component equations of periodicity in the otolith increments. Fig. 18. The empirical record of optical density from otoliths of Ch. gunnarii and harmonic characteristics of the two components from their cyclical increments: daily, 0.0024 mm wide and weekly, 0.02 mm of the displaced series of 503 measurements. 6 5 3 4 8 2 7 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 0,085 0,095 0,105 0,115 0,125 0,135 0,145 0,155 0,165 0,175 0,185 0,195 0,205 0,215 Moc ~A² 95%99%kryt.χ² 95%M.Carlo 99%M.Carlo Teor.AR(1) Frequency Peak₃ f =0.16667 cycle per 0.0004 mm, or per 4 h.; 0.0024 mm/cycle, or 1 day/cycle; Peak₄ f =0.17162 cycle per 0.0004 mm, or per 4 h.; 0.002 mm/cycle, or 1 day/cycle; Peak₅ f =0.11276 cycle per 0.0004 mm, or per 4 h.; 0.003547 mm/cycle, or 1 day/cycle Peak₆ f =0.089219 cycle per 0.0004 mm, or per 4 h.; 0.004483 mm/cycle, or 2 days/cycle; Peak₇ f =0.21747 cycle per 0.0004 mm, or per 4 h.; 0.002 mm/cycle, or 1 day/cycle; Peak₈ f =0.18401 cycle per 0.0004 mm, or per 4 h.; 0.002 mm/cycle, or 1 day/cycle; Peak₂ f =0.20694 cycle per 0.0004 mm, or per 4 h.; 0.002 mm/cycle, or 0.8 day/cycle τ: 7,0239, Bnwith: 0,001499, False-al.: 99,88; oversample: 2; segments: 3 p(random) = 5,96E-48; Runs test for fit to the red noise model: k=348 is outside 5% acceptance interval: 379-431. strong periodic components power ~A² 95%χ² 99%χ² Crit.level χ² 95%Monte Carlo 99%Monte Carlo Theoret. AR(1) 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 0,1 0,11 0,12 0,13 0,14 0,15 0,16 0,17 0,18 0,19 0,2 Moc ~A² y₁=29,27sin(2πx/0,026+0,37)+85 Σᵢ₌₁₋₂(Aᵢ*sin(2πx/Tᵢ+φᵢ))+const. A₁=29,27, φ₁=0,37, T₁=0,0257; A₂=24,6, φ₂=-0,119, T₂=0,0024; ; mm Power ~A²
  • 11. Fig. 19. The empirical record of optical density from otoliths of Ch. gunnarii and harmonic characteristics of the nine components from their cyclical increments of the displaced series of 503 measurements. Fig. 20. Fitting harmonic equations to empirical records of optical density in the otoliths Ch. gunnarii, PAST determine function of circadian increments - green line (R2 = 0.77 is for above function that have a fixed sinusoid of daily increments - No. 8. Without of this daily sinusoid harmonic obtains higher R2). With Solver tool using minimizing the sum of squared deviations periodicity of daily increments is determined from empirical data as the seventh component of the model (double line). 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 0,1 0,11 0,12 0,13 0,14 0,15 0,16 0,17 0,18 0,19 0,2 Moc ~A² Σᵢ₌₁₋₉(Aᵢ*sin(2πx/Tᵢ+φᵢ))+const. mm solver: A₁=29,27, φ₁=0,37, T₁=0,02574; A₂=2,98, φ₂=1,72, T₂=0,00193; A₃=24,6, φ₃=-0,12, T₃=0,0024; A₄=28,8, φ₄=2,22, T₄=0,00233; A₅=14,8, φ₅=-0,15, T₅=0,00355; A₆=4,1, φ₆=0,06, T₆=0,00448; A₇=3,24, φ₇=0,2, T₇=0,00184; A₈=10,2, φ₈=-2,74, T₈=0,00217; A₉=5,96, φ₉=-2,38, T₉=-0,0458, const = 85 Σ(yₑ-yᵢ)²=871443 Power ~A² 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 0,1 0,11 0,12 0,13 0,14 0,15 0,16 0,17 0,18 0,19 0,2 Moc ~A² Σᵢ₌₁₋₉(Aᵢ*sin(2πx/Tᵢ+φᵢ))+const. dopasowane, nieznane A, T, φ: y₇=3,33sin(2πx/0,0021-6,78)+85 mm unknown A, T, φ: A₁=24,2, φ₁=2,19, T₁=0,0248; A₂=25,1, φ₂=-0,242, T₂=0,0331; A₃=17,1, φ₃=-0,881, T₃=0,0662; A₄=16,4, φ₄=-1, T₄=0,0209; A₅=11,7, φ₅=-2,7, T₅=0,0124; A₆=7,44, φ₆=0,437, T₆=0,0058; A₇=7,13, φ₇=-0,876, T₇=0,0083; A₈=1,97, φ₈=-2,22, T₈=0,0024; A₉=18,26, φ₉=-9,64, T₉=-0,07012; const. =85; Σ(yₑ-yᵢ)²=330042 A₉=5,96, φ₉=-2,38, T₉=0,0064; const. =89,05 solver: A₁=31,08, φ₁=1, T₁=0,0263; A₂=3,88, φ₂=-2,5, T₂=0,00417; A₃=9,18, φ₃=-3,5, T₃=0,01566; A₄=9,09, φ₄=3,57, T₄=-0,00812; A₅=0,07, φ₅=3,19, T₅=-0,00076; A₆=4,12, φ₆=-3,27, T₆=0,005; A₇=3,33, φ₇=-6,78, T₇=0,0021; A₈=9,31, φ₈=-7,28, T₈=0,00577 y fitted, unknown A, T, φ Power ~A²
  • 12. Fig. 21. Harmonic model fitted to the profile of optical density along of otolith radius of Ch. gunnarii appointed the same formula of a harmonic function as for the moving fragment. It is composed of a two sinusoids: daily increment peak No 3 and 2 weekly increments – peak No 1. First starting from the otolith center, daily increments are slightly narrower and should be measured separately. However, the nucleus of Ch. gunnarii is small, so the problem with the lack of separate measurements is not large: it seems that from 0 to 0.05 mm instead of 2 periods there are 3. In spite of the various changes in optical density, eg due to environmental changes, the basic pattern of daily increments remains the same along the whole profile of optical density on otolith radius. There are 179 of them (similar to numbers obtained in the profile displacement). Daily peaks describes y3=3,82sin( x[mm] -24,83)+90. Tab. 2. Sinusoids parameters fit to 503 measurements (Ch. gunnarii), daily increments in bold. From spectral analysis of PAST. From fitting sinusoids of PAST. From minimizing the sum of squared deviations (solver) No f A φ T Const. f A φ T Const. A φ T Const. 1 sin 13.7 2.37 0.129119 81.85 cos 24.2 2.19 0.02481 89.05 29.28568448 0.366804749 0.025738099 85 2 sin 2.98 1.72 0.001932 χ² sin 25.1 -0.242 0.033090 χ² 3.133956642 1.062888152 0.001932927 Σ(yₑ-yᵢ)² 3 cos 24.6 -0.119 0.002399 222570 cos 17.1 -0.881 0.06622 160410 1.444064802 -21.4882443 0.002399952 465807 4 sin 28.8 2.22 0.002330 R² sin 16.4 -1 0.020890 R² -0.239585307 -16.98166601 0.002330731 5 cos 14.8 -0.153 0.003547 0.684 cos 11.7 -2.7 0.012400 0.77196 3.66552516 0.744563692 0.003547357 6 sin 4.1 0.0589 0.0045 P sin 7.44 0.437 0.0058 P -3.185641848 -11.31575925 0.00448335 7 sin 3.24 0.203 0.001839 4.8E-114 sin 7.13 -0.876 0.008268 1.54E-148 -0.988937091 -3.94738222 0.001839334 8 sin 10.2 -2.74 0.002173 Akaike IC sin 1.97 -2.22 0.002399 Akaike IC 1.019973039 -17.74347848 0.002173795 9 222538 sin 5.96 -2.38 0.006401 160410 4.853205895 6.200844788 0.006401000 Tab. 3. Sinusoids parameters fit to all 1614 measurements (Ch. gunnarii), daily increments in bold. From minimizing the sum of squared deviations (solver) No f A φ T Const. 1 sin 11.34678543 -1.825153025 0.024976809 89.61 2 sin 2.250685872 2.289589021 0.001937818 Σ(yₑ-yᵢ)² 3 cos 3.817085043 -24.83181682 0.00238518 3577583 4 sin -0.222998561 -24.96633606 0.00229975 5 cos 3.601751213 -1.707692003 0.003529968 6 sin -2.177121558 -1.413467857 0.004584774 7 sin -1.203566121 -5.202701474 0.001832624 8 sin 2.602419876 -15.24427788 0.00218312 9 sin 2.512937926 4.448054353 0.006367814 0 20 40 60 80 100 120 140 160 180 200 220 240 0 0,05 0,1 0,15 0,2 0,25 0,3 0,35 0,4 Moc ~A² Σᵢ₌₁₋₉(Aᵢsin(2πx/Tᵢ+φᵢ))+const. mm solver: A₁=11,35, φ₁=-1,83, T₁=0,02498; A₂=2,25, φ₂=2,29, T₂=0,00194; A₃=3,82, φ₃=-24,83, T₃=0,00239; A₄=-0,22, φ₄=-24,97, T₄=0,0023; A₅=3,6, φ₅=-1,71, T₅=0,00353; A₆=-2,18, φ₆=-1,41, T₆=0,00458; A₇=-1,2, φ₇=-5,2, T₇=0,00183; A₈=2,6, φ₈=-15,24, T₈=0,00218; A₉=2,51, φ₉=4,45, T₉=0,00637; const. =90; Σ(yₑ-yᵢ)²=3577583 Power ~A²
  • 13. Discussion Diurnal increments in otolith satisfy the conditions to describe them as signals periodically variable. Signals – signs of daily increments are multiple repeated at intervals of time: as their name in daily cycle and several repeated at interval of space - here, depending on the species and physiological period: forward every 0.0024 mm for juvenes of Ch. gunnari, or every 0.0009 mm for larvae, 0.0028 mm for juvenes; 0.0034 mm for adults of Ps. georgianus (1). The above harmonic parameters of the otolith formation - daily creation of matter describe the cyclical changes in environment, tidal, in magnetic field which, when run in the air are not saved. In endolymph and in liquid two crystal, that form the otolith surface, above cyclical changes are captured in the pattern of daily increments. Endolymph transfers vibrations and waves that act on otolith and on the particles forming them. One theory for perception of sound is based on creating in endolymph a standing wave forming the local density and thinning, and thus charge changes determining the arrangement of otolith substrates. Arrangement laid down by one, short impulse (at higher concentration parallel arrangament) later does not change, because it is captured, recorded in a protein network and as a disorder causes a further growth of the crystal. Design orientations of microparticles formed by micro-changes further determine the macro form. Otoliths from larvae are almost spherical, Fig. 1 (1). Otoliths grow with surface layers of mixed crystals of collagen network with aragonite. Ingrowing layers form curved surfaces proper to liquid crystals. Thus, they must be formed, depending on the ambient pressure. The larvae inside the eggs at the early stages of setting up bodies, as eggs float freely, or lie. In a motionless otoliths as detectors of motion, acceleration and environment vibration grow in spherical surfaces because their dipolar substrates are distributed almost everywhere in the endolymph with the same probability, at orientation in accordance with distribution of positive and negative charges, radially around the sphere. For propagated in the sea vibrations, environment noises that to their perception are transferred into the marine animals microscopic otoliths with their high density could be their receiver. Otoliths transfer waves with speed 3.5 times faster than sea water (~5000m/s). Endolymph has a concentration and tributary of components regulated that keeps its function and metabolism at the appropriate level. Regulating concentration of the otolith components in the endolymph to equalize the speed of extracting them out from its to the process of crystallization with appropriate its speed, keeps the growth crystal surface at constant diameter with constant dimensions. This determine stability increments and the range of variation determined by changes in endolimfie. When the crystallization rate is higher than the rate of removing substrates from endolymph, the crystal diameter is increasing and vice- versa (10) [str. 456]. Process of otolith growth depends on laying the collagen fibers in the matrix in which their gaps aragonite crystallizes in sizes limited by these gaps. Analyzed vibration, background noise in endolymph, carry cycling to densities of its components, to distribution of charges and to other parameters of the endolymph property, that changes the orientation of the dipoles of otoliths precursors. There are subject to cyclic concentration, accelerating crystallization alternately by recrystallization, facilitating the alignment of both component and the interpenetration into crystallized matrix of otolith.
  • 14. For small larvae of Antarctic fish, the vital information about the environment provide to them vibration and noise from the sea: about the presence of ice, about the presence of krill forming various concentrations depending on the environment (11), and thus the background noise. This information allows them to locate food, threats, hiding. Because of that from the start of growth of larval runs specialization of organ vibration perception - otoliths to these sounds and vibrations, which determines their free life in the sea (12). Organisms without otolith, or statoliths is sedentary, associated with the bottom (13). For fish larvae may be less important sounds generated by large marine organisms, but with the development, and through development – growth of otolith, this organ of perception will recognize them. Width of daily increments of Ps. georgianus larvae developing in the eggs are narrower than those for juvenile and adult fish (1), living in different zones of the sea. But for juveniles of Ch. gunnari and Ps. georgianus widths of their increments are similar, as they share similar environment. The analyzed species perform diurnal vertical migrations, thus periodically changing the acoustic field. With increasing depth sound amplitude decreases (for pressures of 15 dB from 0.00086 to 0.00026 cm, for pressures of 70 dB from 0.48251 to 0.14641 cm) and the speed of sound decreases. With the depth noise from the waves disappear and there are conditions that increase the possibility of the perception of weak signals of biological activity. Generally fish are responsive to audio signals, when they are to noise in the ratio of not less than 1/5. Sounds specific to feeding 5000 Hz pressure of 50 N/m2 are received under no noise, from a distance of 70 m (with noise waving 1 ° B from the 3.5 m). Spawning sounds 100 Hz with pressure of 1000 N/m2 are received from a distance of 300 m (at wave of 1 ° B from 30 m, 2 ° B from 10 m, 4 ° B from the 9 m). Environmental noise can help to hear, could result in changes that increase hearing sensitivity. Acoustic waves from different sources carry information about the factors changing them in the form specific to those factors emitted frequency and sound pressure. Various changes of acoustic waves from a fixed known source may provide information on factor specific changing the radiated waves (differently amended by the air bubbles, differently from schools of fish or krill and even differently by the bottom, also depending on whether it is muddy, sandy or rocky). Collection this information for the receiving marine organisms provides picture of the environment changes corresponding to the image from the light waves in the atmosphere for organisms equipped with organs of sight. Krill in large densities protects larvae of fish, giving them the environment to develop, changing the physico - chemical properties of Antarctic waters on favorable to the development of larvae and juvenes present in its clusters, Fig. 22, (14). High densities of krill form a "moving, living ocean", causing bio-turbulent waters of size effects almost equal to the effect of mixing water in the tide, or with wind action (15; 16) – frequencies for wind are above 100 Hz and sound pressure 48 ÷ 20 ÷ -5 dB. Noise from turbulent flow of water masses also mean the presence of krill - which form there its higher concentrations (11). Ice cover also modifies the sea water, provides shelter and allows fish to extend their propagation for food. Noise caused by moving ice are frequencies 9 ÷ 5000 Hz, wherein the waters of completely ice-covered frequencies are from 1 to 10000 Hz with sound pressure of 45 dB to -15 dB, in which from 40 to 1000 Hz sound pressure run above the average of the minimum the sound pressure of own
  • 15. noise of sea, i.e. in the range from 20 to 5 dB, in the remaining range is less than that average. In the marine environment above noise carry information on changes in the environment, which is mostly in cyclical nature – noise of ice edge is cyclical daily from tides that stand out at the coast of Antarctica, with possibly reflection in the oscillation of the southern edge of the ice cover. Fig. 22. Oscillation of the southern edge of the ice cover and occurrence of larvae of fish in the krill fishery (marked by arrows) carried out in the ice marginal zone between South Orkney and Elephant Island during an expedition on rv. "Professor Siedlecki" in season 1988/89 (17). Arrows – krill catches containing fish larvae of the following species: Ch. aceratus (40,66); Ch. gunnarii (41); Chionodraco rastrospinosus (41,66,78); Chaenodraco wilsoni (69,73,74); Dissostichus eleginoides (73); Pleurogramma antarcticum (40,74); Gryodraco antarcticus (40,73,74,82); Neopagetopsis sp. (55); Neopagetopsis ionach (56,71,73); Trematomus eulepidotus (65); Notolepis coatsi (67,71); Pagetopsis sp. (69,78,82); Notothenia sp. (69); Notothenia larseni (73;74); Pagetopsis macropterus (73); Electrona carlsbergi (78). To environmental cycles, with the development of organisms synchronize physiological cycles, which at the beginning of synchronization may be reflected in circadian cycles - due to the complex process of adapting many of the currently formed biological, internal functions in the larval development. It appears that for fishes does not exist a practical lower limit of sensed sounds. For the range of infrasound (sound waves of low frequency) function of receptors take over the organs of touch. Even more simple statolith enable bivalve Donax to choose from complex sounds generated by the waves, the right kind of wave to use it to achieve success in reproduction. Conclusions Results are probable: larvae physiological cycles are usually circadian - at above model for fish larvae the highest amplitudes are characterized by circadian cycles, A4, A5. They may result from the transformation of the larvae to adapt to the daily cycle. Time sinusoid parameters employed to describe time increments of otolith does not necessarily correspond with the parameters of the acoustic waves. Three theories of perception of sounds shall indicate more work in this direction. Sine wave of daily increments separated component from sinusoids model, enables fast measurement of their number and width. Obtained similar values of mean daily increment in three independent methods: 1. search for the minimum difference in optical density of otoliths when relative moving their profiles to each other. kg/h 3 kg/h 14 kg/h 78 82 74 73 71 40 41 69 67 66 65 56 55
  • 16. 2. harmonic analysis of REDFIT (4). 3. fit of the harmonic model to empirical data by minimizing the sum of squared deviations. Use solver tool - the most accurate method. Records of optical density otolith increments can be a valuable material for the study of biological, physical and evolutionary (13) in the marine environment. However, at noise emissions are weak, treated as irrelevant and discarded from the analysis, in the appropriate scale for the micro-level organizations can be important synchronisers of cyclicality - particularly for a large number of larvae - thus determining the mass gain, the success of generations and even existence of a species being closely related to the free way of life in vast, poor at food and raw space of Antarctic Ocean. Lack of synchronization conditioning for species their lifestyle adapted to the environment may be partly responsible for the disappearance of that timing-dependent species. No cover surface of the ocean by ice reaching in the 70's up to Georgia Pd, coincides with the long kept decline of fish Pseudochaenichthys georgianus by 75% - despite a ban on their fishing. Meanwhile, the open ocean and bottom species does not associated with the neighborhood of ice edge are present in an amount does not less, but even more (18). Cited works 1. Traczyk, R.J. Zastosowanie analizy mikroprzyrostów i morfologii otolitów georgianki (Pseudochaenichthys georgianus Norman, 1939) z rejonu Georgii Południowej (Antarktyka) do określenia wieku, wzrostu oraz ważniejszych okresów rozwoju ryb. Kraków : Ryszard Traczyk In Altum, ISBN: 978-83-62841-10-3, 2013. 2. Kota, M. Basics of Image Processing and Analysis. EMBL Heidelberg : Centre for Molecular & Cellular Imaging, 2013. Copyright 2006 - 2013, Kota Miura (http://cmci.embl.de). 3. Parkes, G., I. Everson, J. Anderson, Z. Cielniaszek, J. Szlakowski, R. Traczyk. Report of the UK/Polish fish stock assessment survey around South Georgia in January 1990. London : Imp.Coll. of Sci. & Techn., 1990, str. 20. 4. Hammer, Ø. Time series analysis with Past. Oslo : Natural History Museum, University of Oslo., 2010. 5. Schulz, M., M. Mudelsee. REDFIT: estimating red-noise spectra directly from unevenly spaced paleoclimatic time series. GE : Computers & Geosciences 28, 421-426., 2002. 6. Kaczkowska, A. Transformacje Fouriera, DFT, FFT, Periodogram Lomba-Scargle’a. Gdańsk : Politechnika Gdańska, 2009. 7. Kozłowski, E. Analiza spektralna. Wrocław : GUM, Zakł. Fizykocemii, http://bip.gum.gov.pl/, 2013. 8. NASA. Algorithm Documentation. NJ : NASA Exoplanet Archive, 2012. http://exoplanetarchive.ipac.caltech.edu/applications/Periodogram/docs/Algorithms.html. 9. UF. Lomb-Scargle Periodogram. FL : University of Florida, EEL, 6537, 2009. 10. Anonymous, 1983. Encyklopedia Fizyki Współczesnej. W-wa : PWN, 1983. str. 1072. 11. Witek, Z., J. Kalinowski, A. Grelowski. Formation of Antarctic Krill Concentrations in Relation to Hydrodynamic Processes and Social Behaviour. [aut. książki] D. Sahrhage. Antarctic Ocean and Resources Variability. Berlin : Springer-Verlag, 1988. 12. Mitrinowicz - Modrzejewska, A. Fizjologia i patologia głosu, słuchu i mowy. W-wa. : Państw. Zakł. Wyd. Lek., 1963. str. 307. 13. Traczyk, R. Migrations of Antarctic fish Pseudochaenichthys georgianus Norman, 1939 in the Scotia Sea. Hobart : CCAMLR. WG-FSA-12/68 Rev. 1, 2012. 14. Ślósarczyk, W., Z. Cielniaszek. Postlarval and juvenile fish (Pisces, Perciformes and
  • 17. Myctophiformes) in the Antarctic Peninsula region the Antarctic Peninsula region, 1983/1984. 1-2. W-wa : Pol. Polar Res., 1985. strony 159-165. Tom 6. 15. Harmon, K. Shrimpy Sea Life May Mix Oceans as Much as Tides and Winds Do. bio-ocean- mixing. [Online] Scientific American, 29 VII 2009. http://www.scientificamerican.com/article.cfm?id=bio-ocean-mixing. 16. Pyper, W. Krill mix up the ocean. Tasmania : Australian Antarctic Magazine, 2008. 17. Traczyk, R. The occurrence of krill Euphausia superba in the floating ice edge zone and some its biological data. http://georgianka.strefa.pl/krill_oc.html. [Online] INTERIA.PL S.A., 1993. 18. Traczyk, R. Economic competition for high profits from Antarctic living resources in protection area and Mercury contaminants of fish from outside. Hobart : CCAMLR WG-EMM-13/04, 2.1.1, 2013.