SlideShare a Scribd company logo
1 of 32
Download to read offline
FIRE DOORSET 
DELTA 
VOLTA 
TURIA 
TURIA PREMIUM 
TURIA DOUBLE OPENING SENSE 
FONO-TURIA 
SIGMA 
METER DOORS 
ACCESSORIES
OPENING DOORS TO 
THE FUTURE 
E-doors BV 
Mauritskade 55C 
1092 AD Amsterdam 
020-2611839 
info@e-doors.nl 
www.e-doors.nl 
All rights reserved. 
Total or partial reproduction prohibited. 
The company reserves the right to make modifications without prior notice. 
Our state-of-the-art production systems and our excellent work 
team gives us a competitive edge in an increasingly complex 
and demanding market. We are specialized in providing new 
ideas for our customers’ projects, incorporating an added value 
and a guarantee of quality in each new model. 
Our quality management system for the design, production and 
sales processes of all our lines of steel doorset and hardware is 
certified by the AENOR in accordance with the UNE-EN-ISO 
9001:2000 standards. 
E-doors BV opens new doors to the future. 
2
OUR FIRE DOOSET 
Life for your Home 
Some of the main concerns and obligations for architects 
and constructors are the planning and construction of safe, 
habitable buildings. Security begins with prevention and the 
selection of adequate structural materials and components, 
such as fire-doorsets, an essential protective element 
against the destructive force of fire. As a result, the use of 
fire-doorsets is mandatory in certain locations, in accordance 
with current regulations. 
E-doors BV has more than 40 years experience 
in the development of ever-more advanced technological 
solutions. The range of fire-doorsets is the fruit of this effort 
and of our know-how in the manufacture of high-quality 
steel doors. 
EI2 t C5 
3
Index 
Delta 5 
Volta 7 
Turia 9 
Turia Double Leaf 11 
Turia Premium 13 
Turia Premium Double Leaf 14 
Turia Double Opening Sense 15 
Fono-Turia 17 
Sigma 19 
Meter Doors 23 
Accessoires 28 
4
SINGLE LEAF FIRE RATED DOORSET EI2 60 C5 DELTA 
Delta model is our most economic fire-door 
featuring the most advanced technological 
innovations, and a structure similar to the 
rest of doorset in the same range. The door 
is characterized by its easy installation and 
maintenance. 
Built and assembled without welding, the doorset 
is classified in the EI2 60 category, after having 
passed the tests carried out in an approved 
laboratory. 
Available in standard dimensions only. 
EI2 60 C5 
· GALVANISED 
+Antifinger-print 
Protection 
· Other RAL 
to select 
· WHITE 
prelacquered 
9010 
5
Technical Characteristics - Delta Doorset 
Sheet Galvanised steel 
+antifinger-print 
What is the ANTIFINGER-PRINT 
PROTECTION? 
The Antifinger-print finish is a 
clear prime as a supplement 
over the galvanised. 
Allow the doorset 
to be painted 
directly, without 
the need of 
a prime-washer. 
3 advantages 
Provide a 
greater 
anti-corrosive 
protection. 
Aspect is grey, 
transparent, 
homogeneous 
and not oily. 
Height-adjustement 
Exploded view 
of the hinge 
Coverplates 
Lever Handles 
40 
21.5 
1.2 
CS5 Model (Optional) 
48 
68 
10 
10 
72.5 
10 
Rubber seal 
Intumescent Seal 
Steel anchor 
DOOR OPENING 
LEFT HAND RIGHT HAND 
CS5 Frame Brick to Brick Internal 
frame size Door leaf size Overall size 
Model Width Height Width Height Width Height Width Height 
DE 800 x 
2050 
800 
2050 
780 
2040 
700 
2000 
836 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
DE 900 x 
2050 
900 
2050 
880 
2040 
800 
2000 
936 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
DE 1000 x 
2050 
1000 
2050 
980 
2040 
900 
2000 
1036 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
DE 1100 x 
2050 
1100 
2050 
1080 
2040 
1000 
2000 
1136 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
DE 1200 x 
2050 
1200 
2050 
1180 
2040 
1100 
2000 
1236 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
Measurements in millimetres. 
Contact us for made-to-measure orders. 
Leaf Frame 
Standard Measurements 
The HANDLE SYSTEM included in the standard range comprises two lever 
handles made of a highly-resistant material, coverplates and backplates, also 
made of the same material, with key-holes on both sides. 
When installing the frame into a brick wall, always use cement-based mortars 
and do not use plaster or other derivatives. (Plaster attacks the zinc coating 
which protects the galvanised steel against corrosion). 
The CS5 frame can be screwed onto a specially designed galvanised steel 
SUB-FRAME, which is optional, and allows the easy installation of the door 
once the construction works are completed (see page 26 et 27). 
Its STRUCTURE consists of two non-welded 0’7-mm-thick galvanised steel 
sheet with “antifinger-print” protection. The doorset is also available in pre-lacquered 
white steel finish. 
The doorset is equipped with 2 HINGES own manufacturing of 3 mm thickness 
screwed onto the leaf and assembled to the frame. Certified CE Mark 
according to EN-1935. 
A central steel anti-crow bar bolt for improved security is incorporated into the 
frame. 
The LOCKING SYSTEM includes a mortice lock of one-point locking system 
with CE Mark according to EN-12209:2007. The system also comprises a 
35x35 brass cylinder with keys. 
The profile of this doorset is mounted onto a frame called CS5 made of 1’2 
mm-thick galvanised steel. 
An intumescent seal or rubber seal can also be installed even if the door is 
not equipped with a seal. 
3 galvanised steel anchors on each side, allowing the frame to be installed in 
brickwork, or screwed onto a sub-frame. 
6
· GALVANISED 
+Antifinger-print 
Protection 
· Stainless 
Steel 
· Other RAL 
to select 
· WHITE 
prelacquered 
9010 
REVERSIBLE 
SINGLE LEAF FIRE RATED DOORSET EI2 30-60-90 C5 VOLTA 
The Volta doorset is our most practical fire 
rated steel doorset essentially characterized by its 
REVERSIBILITY. 
This high-quality designed doorset is easily 
ADAPTABLE, as it can be installed to open either 
towards the right or the left. 
The doorset is built and assembled without welding. 
It is classified as EI2 30-60-90, in accordance with 
the tests carried out in an approved laboratory. 
EI2 30 C5 
EI2 60 C5 
EI2 90 C5 
7
Technical Characteristics - Volta Doorset 
Leaf 
The STRUCTURE consists of two non-welded 0’8 mm thick 
galvanised steel sheets. The doorset is also available in pre-lacquered 
Its INTERIOR is filled with a combination of fire-resistant 
materials. The door is 63 mm thick, with a 16 mm wide and 
2mm thickness edge. 
The door is equipped with 3 height-adjustable HINGES 
screwed onto the leaf and an automatic locking system. 
The LOCKING SYSTEM comprises a mortice lock with a one-point 
cylinder with keys. 
The HANDLE SYSTEM included in the standard range 
comprises two handles made of a highly-resistant material, 
cover-plates and casing, also made of the same material, with 
key-holes on both sides. 
CS5 Frame Brick to Brick Internal frame size Door leaf size Overall size 
Model Width Height Width Height Width Height Width Height 
VO 800 x 2050 800 2050 780 2031 700 2000 836 2031 
VO 900 x 2050 900 2050 880 2031 800 2000 936 2031 
VO 1000 x 2050 1000 2050 980 2031 900 2000 1036 2031 
VO 1100 x 2050 1100 2050 1080 2031 1000 2000 1136 2031 
VO 1200 x 2050 1200 2050 1180 2031 1100 2000 1236 2031 
White finish. 
locking. The system also comprises a 35 x 35 brass 
DOOR OPENING (reversible) 
REVERSIBLE 
LEFT HAND RIGHT HAND 
CROSS-SECTION A-A’ 
OVERALL SIZE 
INTERNAL FRAME SIZE = BRICK TO BRICK - 19 
DOOR SIZE = BRICK TO BRICK - 50 
BRICK TO BRICK = H 
OVERALL SIZE 
A 
B B’ 
A’ 
CROSS-SECTION B-B’ 
INTERNAL FRAME SIZE = BRICK TO BRICK + 36 
DOOR LEAF SIZE = BRICK TO BRICK - 100 
OVERALL SIZE = BRICK TO BRICK - 20 
BRICK TO BRICK = A 
Cross-Section of frame (Upper and Lower) 
10 
31 
20 
70.1 
1.5 
11 
CS5 Model 
Rubber seal 
(Optional) 
40 
Rubber seal 
(Optional) 
1.5 
Intumescent Seal 
48 
68 
10 
72.5 
10 
21.5 
10 
Intumescent Seal 
Measurements in millimetres. 
Contact us for made-to-measure orders. 
Standard Measurements 
Frame 
The doorset is mounted onto a CS5 FRAME made of 1’5 mm 
thickness galvanized steel. The cross-section of the frame 
differs according to the width for reversibility purposes. 
4 galvanized steel anchors on each side, allowing the frame to 
be installed in brickwork, or screwed onto a sub-frame. 
The doorset comprises an expanding graphite joint. The 
fitting of a rubber seal is optional. 
8
FIRE RATED DOORSET 1 & 2 LEAVES EI2 30-60-90-120 C5 TURIA 
The Turia fire-doorset is available in four models: 
single-leaf, double-leaf, double-leaf asymmetric 
and meter doors. 
Characterized by their great versatility, both 
the frame and the leaf of this range of door are 
manufactured in different finishes, in accordance 
with the requirements of specific projects, and 
incorporate various accessories, many designed 
exclusively. These doorset fulfill the double 
function of security and design, and provide 
effectiveness and adaptability to any architectural 
setting. 
EI2 30 C5 
EI2 60 C5 
EI2 90 C5 
EI2 120 C5 
· GALVANISED 
+Antifinger-print 
Protection 
· Stainless 
Steel 
· Other RAL 
to select 
· WHITE 
prelacquered 
9010 
9
Technical Characteristics - Turia Doorset 
CROSS-SECTION A-A’ 
OVERALL SIZE 
OVERALL SIZE = BRICK TO BRICK SIZE+18 
DOOR LEAF SIZE = BRICK TO BRICK SIZE - 50 
INTERNAL FRAME SIZE = BRICK TO BRICK SIZE - 10 
OVERALL SIZE 
A 
B B’ 
A’ 
CROSS-SECTION B-B’ 
OVERALL SIZE = BRICK TO BRICK SIZE + 36 
DOOR LEAF SIZE = BRICK TO BRICK SIZE - 100 
INTERNAL FRAME SIZE = BRICK TO BRICK SIZE - 20 
BRICK TO BRICK SIZE 
The STRUCTURE of the Turia EI2 30-60-90 consists of two 
non-welded 0’8 mm thickness galvanised steel sheets. 
The doorset is 63 mm thick, with a 16 mm wide and 2 mm 
thickness edge. 
The EI2 120 Turia doorset is built with 3 galvanised steel 
sheets, with a “reinforcement” plate on the pan side of the door. 
Its leaf is 74 mm thick. 
The doorset is also available in White finish or Stainless steel 
finish, and other RAL upon request. 
Its INTERIOR is filled with a combination of fire-resistant 
materials. 
The doorset is equipped with 3 steel galvanised HINGES 
own manufacturing of 3mm thick, screwed onto the leaf and 
assembled onto the frame. Certified in accordance with EN- 
1935 and CE Mark. 
The LOCKING SYSTEM comprises a mortice lock with one 
and 3 points (in 1 leaf). Certified CE Mark according to EN 
12209:2004. The system also includes a 35x35 or 35x50 (for 
EI2 120 door) brass cylinder with the keys. 
The HANDLE SYSTEM included in the standard range 
comprises two lever handles made of a highly-resistant 
material, cover-plates and back plates with key holes on both 
sides. 
CS5 Model 
40 
Rubber seal 
(Optional) 
1.5 
Intumescent Seal 
48 
68 
10 
72.5 
10 
21.5 
10 
BRICK TO BRICK SIZE 
63 
Turia Doorset 
EI2 30-60-90 
OVERALL SIZE = BRICK TO BRICK SIZE+ 36 
DOOR LEAF SIZE = BRICK TO BRICK SIZE - 100 
INTERNAL FRAME SIZE = BRICK TO BRICK SIZE - 20 
BRICK TO BRICK SIZE 
74 
Turia Doorset 
EI2 120 
CS5 Frame Brick to Brick Internal frame size Door leaf size Overall size 
Model Width Height Width Height Width Height Width Height 
TU 800 x 
Measurements in millimetres. 
Contact us for made-to-measure orders. 
2050 
800 
2050 
780 
2040 
700 
2000 
836 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
TU 900 x 
2050 
900 
2050 
880 
2040 
800 
2000 
936 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
TU 1000 x 
2050 
1000 
2050 
980 
2040 
900 
2000 
1036 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
TU 1100 x 
2050 
1100 
2050 
1080 
2040 
1000 
2000 
1136 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
TU 1200 x 
2050 
1200 
2050 
1180 
2040 
1100 
2000 
1236 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
Leaf 
3 points lock 
Standard Measurements Frame 
The doorset is mounted onto a CS5 FRAME made of 1’5 mm 
thickness galvanised steel. 
4 galvanised steel anchors on each side, allowing the frame to 
be installed in brickwork, or screwed onto a sub-frame. 
The doorset is also equipped with an intumescent seal. The 
fitting of a rubber seal is optional. 
A specially designed SUB-FRAME onto which the CS5 frame 
can be screwed is also available. This sub-frame allows the 
easy installation of the door once the construction works are 
completed (see page 15). 
10
Technical Characteristics - Turia Double Leaf Doorset 
CROSS-SECTION A-A’ 
OVERALL SIZE = BRICK TO BRICK SIZE+18 
DOOR LEAF SIZE = BRICK TO BRICK SIZE - 50 
INTERNAL FRAME SIZE = BRICK TO BRICK SIZE - 10 
CROSS-SECTION B-B’ 
BRICK TO BRICK SIZE 
OVERALL SIZE 
OVERALL SIZE 
A 
B B’ 
A’ 
OVERALL SIZE = BRICK TO BRICK SIZE+ 36 
63 
ACTIVE LEAF SIZE 
DOOR LEAF SIZE = BRICK TO BRICK SIZE -100 
INTERNAL FRAME SIZE = BRICK TO BRICK SIZE -20 
BRICK TO BRICK SIZE = A 
OVERALL SIZE = BRICK TO BRICK SIZE+ 36 
74 
ACTIVE LEAF SIZE 
DOOR LEAF SIZE = BRICK TO BRICK SIZE -100 
INTERNAL FRAME SIZE = BRICK TO BRICK SIZE -20 
BRICK TO BRICK SIZE = A 
Measurements in millimetres. 
Contact us for made-to-measure orders. 
Turia Doorset EI2 30-60-90 
Turia Doorset EI2 120 
CS5 Frame Brick to Brick Internal frame 
size Door leaf size Overall size 
Model Width Height Width Height Width Height Width Height 
DH TU 1200 x 
2050 
1200 
2050 
1180 
2040 
1100 
2000 
1236 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
DH TU 1300 x 
2050 
1300 
2050 
1280 
2040 
1200 
2000 
1336 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
DH TU 1400 x 
2050 
1400 
2050 
1380 
2040 
1300 
2000 
1436 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
DH TU 1500 x 
2050 
1500 
2050 
1480 
2040 
1400 
2000 
1536 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
DH TU 1600 x 
2050 
1600 
2050 
1580 
2040 
1500 
2000 
1636 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
DH TU 1700 x 
2050 
1700 
2050 
1680 
2040 
1600 
2000 
1736 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
DH TU 1800 x 
2050 
1800 
2050 
1780 
2040 
1700 
2000 
1836 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
DH TU 1900 x 
2050 
1900 
2050 
1880 
2040 
1800 
2000 
1936 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
DH TU 2000 x 
2050 
2000 
2050 
1980 
2040 
1900 
2000 
2036 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
DH TU 2100 x 
2050 
2100 
2050 
2080 
2040 
2000 
2000 
2136 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
DH TU 2200 x 
2050 
2200 
2050 
2180 
2040 
2100 
2000 
2236 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
Retainer 
Rod 
Automatic cremone 
lock with CE Mark 
Rod 
Electric slike 
Electric strike 
connecting tube. 
The Double Leaf Turia EI2 120 C5, is similar to the Turia single 
leaf EI2 120 C5: it’s built with 3 galvanised steel sheets, with a 
“reinforcement” plate on the pan side. Its leaf is 74 mm thick. 
This double leaf doorset is also available in white prelaquared 
finish and stainless steel and for any other finish upon request. 
The ACTIVE LEAF has the same characteristics as the TURIA 
model. 
The interior of the INACTIVE LEAF is the same than its 
active counterpart, except that it incorporates an automatic 
cremone lock (instead of the traditional bolt lock system 
installed on the edge). 
Standard Measurements 
This mechanism comprises the 
following parts: 
- Retainer in the upper part of the 
inactive leaf. 
- Rods fitted into the interior of the 
inactive leaf. 
- An automatic closing system for 
the cremone lock. 
- 9 mm mortice lock. 
When the handle of the inactive leaf is activated, the locking 
mechanism of the door is released, opening the door. 
This mechanism allows the installation of panic bars 
without having to install external fasteners, improving 
appearance and efficiency. 
The electric stike is certidied for this model in 1 and 2 leaves 
for 30, 60 and 90 minutes. 
11
Technical Characteristics – TURIA asymmetric double leaf doorset 
The Asymmetric Double Leaf Doorset characteristics are exactly the same as a Turia Double Leaf Doorset, except for the width of the active 
leaf, which differs from that of the inactive leaf. This mechanism also allows for the installation of panic bars. The asymmetry of the Turia 
double leaf differs according the requirements of each project. 
TURIA fix panels 
Fix panels are a solution specially developed by Andreu to cover any space on a site with our standard doorset. 
The structure is based in Turia doorset and depending on the space, fix panels can be installed above or on the side of the doorset. Moreover, 
we can produce with or without intermediate frame between the fix panel and the door leaf. In both cases we have them certified EI2 60, 
according to the standard UNE-EN 1634:2002. 
Upper and lateral fix panel without intermediate frame 
CROSS-SECTION A-A’ OVERALL SIZE 
BRICK TO BRICK SIZE 
A 
A’ 
OVERALL SIZE 
OVERALL SIZE 
DOOR LEAF SIZE 
Upper fix panel 
TURIA EI2’60 
CROSS-SECTION A-A’ 
OVERALL SIZE (OVERALL DOOR + OVERALL FIXED PANEL) 
OVERALL FIXED PANEL 
OVERALL SIZE 
OVERALL DOORSET 
OVERALL 
A FIXED PANEL 
A’ 
A A’ 
OVERALL SIZE (OVERALL DOOR + OVERALL FIXED PANEL) 
OVERALL SIZE = BRICK TO BRICK SIZE + 18 
OVERALL FIXED DOOR 
Fix panel and door leaf are build with the same frame. 
In this case, door leaf is in direct contact with the fix panel. 
This structure is an esthetical and light solution, which is 
normally used for upper fix panels. 
Upper fix panel with intermediate frame 
In this case the fix panel is independent from the doorset, where each one has is own frame. This solution is better for bigger dimensions 
and it’s the best solution for fix panels with glass. 
12
FIRE RATED DOORSET 1 & 2 LEAVES EI2 60 C5 TURIA PREMIUM 
E-doors five-stars Fire-Doorset. Turia Premium 
door has been developed in order to supply 
the market with a high level Fire-Doorset thanks 
to its high mechanical resistance, its wide 
sturdiness and the variety of finishings and 
accessories. 
Turia Premium doorset has 5 stainless steel 
hinges, a reinforcement plate of 10 mm thickness 
and a sub-frame as standard. 
Turia Premium doorset can be installed with 
the supplied sub-frame, specially designed by 
Andreu, in a brick wall or plasterboard wall, without 
loosing the certificate EI2 60 C5. 
EI2 60 C5 
· Stainless 
Steel 
· Other RAL 
to select 
· GREY 
RAL 7043 
13
Technical Characteristics - Turia PREMIUM 
CS5 Frame Brick to Brick Internal frame 
size Door leaf size Overall size 
Model Width Height Width Height Width Height Width Height 
TUP 800 x 2150 800 2150 780 2140 700 2100 836 2168 
TUP 900 x 2150 900 2150 880 2140 800 2100 936 2168 
TUP 1000 x 2150 1000 2150 980 2140 900 2100 1036 2168 
TUP 1100 x 2150 1100 2150 1080 2140 1000 2100 1136 2168 
TUP 1200 X 2150 1200 2150 1180 2140 1100 2100 1236 2168 
CROSS-SECTION A-A’ OVERALL SIZE 
OVERALL SIZE 
A 
CROSS-SECTION B-B’ 
Rubber seal 
CS5 Model 
B B’ 
Intumescent Seal 
40 
21.5 
1.2 
48 
68 
DOOR LEAF SIZE 
INTERNAL FRAME SIZE 
BRICK TO BRICK SIZE 
10 
10 
72.5 
10 
OVERALL SIZE 
A’ 
BRICK TO BRICK SIZE 
INTERNAL FRAME SIZE 
DOOR LEAF SIZE 
OVERALL SIZE 
OVERALL SIZE 
B B’ 
CROSS-SECTION B-B’ 
OVERALL SIZE 
A 
A’ 
OVERALL SIZE = BRICK TO BRICK SIZE+36 
ACTIVE LEAF SIZE 
DOOR LEAF SIZE = BRICK TO BRICK SIZE - 100 
INTERNAL FRAME SIZE = BRICK TO BRICK SIZE - 20 
BRICK TO BRICK SIZE = A 
CS5 Frame Brick to Brick Internal frame 
size Door leaf size Overall size 
Model Width Height Width Height Width Height Width Height 
2L TUP 1200 x 2150 1200 2150 1180 2140 1100 2100 1236 2168 
2L TUP 1300 x 2150 1300 2150 1380 2140 1300 2100 1336 2168 
2L TUP 1400 x 2150 1400 2150 1480 2140 1400 2100 1436 2168 
2L TUP 1500 x 2150 1500 2150 1580 2140 1500 2100 1536 2168 
2L TUP 1600 x 2150 1600 2150 1680 2140 1600 2100 1636 2168 
2L TUP 1700 x 2150 1700 2150 1780 2140 1700 2100 1736 2168 
2L TUP 1800 x 2150 1800 2150 1880 2140 1800 2100 1836 2168 
2L TUP 1900 x 2150 1900 2150 1980 2140 1900 2100 1936 2168 
2L TUP 2000 x 2150 2000 2150 2080 2140 2000 2100 2036 2168 
2L TUP 2100 x 2150 2100 2150 2180 2140 2100 2100 2136 2168 
2L TUP 2200 x 2150 2200 2150 2280 2140 2200 2100 2236 2168 
Retainer 
Rod 
Automatic cremone 
lock with CE Mark 
Rod 
Measurements in millimetres 
Contact us for made-to-measure orders. 
Measurements in millimetres 
Contact us for made-to-measure orders. 
Single leaf 
Turia Premium EI2 60 C5 STRUCTURE is based in 3 non-welded and prelacquered 
antifinger steel plates of 1 mm thickness. The doorset is 75 mm thick and has a lid in 
his structure; and has an edge of 16 mm wide and 2 mm thick. 
Its INTERIOR is filled with a combination of fire-resistant materials. 
The door has 5 stainless steel HINGES of 3 mm thickness. They are made accordingly to 
our own design and to the norm UNE-EN 1935. Moreover they are CE marked. They are 
screwed to the leaf and assembled to the frame. 
The LOCKING SYSTEM comprises a stainless steel mortice lock with one point locking 
system. It’s also CE marked accordingly to norm UNE-EN 12209:2004. The system also 
comprises a 35x35 nickel cylinder with keys. 
The HANDLE SYSTEM included in the standard range comprises a TESA brand stainless 
steel square cover plate with handle and keyhole, model SENA. 
The door is mounted onto a CS5 frame made of 1,5 mm thickness galvanized steel. 
4 galvanised steel anchors on each side, allowing the frame to be installed in brickwork or 
screwed onto a sub-frame. 
The doorset comprises a graphite intumescent seal and a rubber seal. 
A SUB-FRAME is also comprised, certified and specially designed to screw our CS5 frame. 
To allow an easy installation once the work is finished. (Look sub-frame chapter). 
Doble leaf 
Turia Premium double leave EI2 60’s STRUCTURE is based in 3 non-welded and 
prelacquered antifinger steel plates of 1 mm thickness. The doorset is 75 mm thick and 
has a lid in his structure; and has an edge of 16 mm wide and 2 mm thick. 
The ACTIVE LEAF has the same characteristics than Turia model, excepts its thickness 
leaf and steel sheat. 
The INACTIVE LEAF structure is similar to the active leaf, excepts for the automatic 
cremone lock (instead of the flush bolt). This mechanism has: 
- Retainer in the top of the inactive leaf. 
- Rods inside the inactive leaf. 
- Automatic cremone lock. 
- 9 mm mortice lock. 
When the inactive leaf’s handle is moved, the automatic cremone lock is released and the 
door is opened. 
The mechanism allows the installation of panic bars without incorporating external 
rods: which is an improvement of the door’s aesthetics and efficiency. 
14
TURIA DOUBLE OPENING SENSE 
· GALVANISED 
+Antifinger-print 
Protection 
DOUBLE LEAVES FIRE RATED DOORSET EI2 60 C5 
· Stainless 
Steel 
· Other RAL 
to select 
· WHITE 
prelacquered 
9010 
Turia Double Opening Sense’s STRUCTURE is made 
with 2 galvanized steel sheets of 0,8 mm thickness, 
assembled without welding and with the antifinger 
protection plus the epoxy painting. It’s thickness is 63 
mm, with a 16 mm width and 2 mm thickness rebate. 
Its INSIDE is made with different fire-proof and 
thermical isolation materials. 
With 3 HINGES in 3 mm thickness steel, made with 
our own design, CE marked according to UNE-EN1935: 
2002 standard. The hinges are screwed to 
the leaf and assembled to the frame 
The frame used in this doorset model is the C7 DS, 
made with 1 width and 2 jambs from the same model, 
where are screwed 2 rods of CS5 frame through nuts. 
This frame has to be filled with concrete during the 
installation. That’s why the jambs of this frame has 
been prepared to facilitate the filling. 
An intumescent seal in graphite is incorporated in 
the jambs and the width of the frame. 
C7 DS frame has a lower bar to facilitate the installation 
of the door, indicating the floor level. 
EI2 60 C5 
15
Technical Characteristics -Turia Double Opening Sense 
Double Opening Sense doorset is similar to a Turia Double Leaf doorset, exception of its Double Opening Sense. This means, that each one 
of the leaves are opening in a different sense. That’s why this doorset is mostly used in hospitals. 
DOOR LEAF SIZE 
C7DS Frame Brick to Brick Door leaf size Overall size 
Model Width Height Width Height Width Height 
2L TU 1800 GADS 1800 2091 1600 2000 1800 2091 
2L TU 1900 GADS 1900 2091 1700 2000 1900 2091 
2L TU 2000 GADS 2000 2091 1800 2000 2000 2091 
2L TU 2100 GADS 2100 2091 1900 2000 2100 2091 
2L TU 2200 GADS 2200 2091 2000 2000 2200 2091 
2L TU 2300 GADS 2300 2091 2100 2000 2300 2091 
Measurements in millimetres. 
Contact us for made-to-measure orders. 
CROSS-SECTION A-A’ 
OPPENING 
CROSS-SECTION B-B’ 
Intumescent sealing 
100 
90 
Intumescent Seal 
60 40 
32 48 
80 
70 
CS5 Frame 
Double 
Sense Openning 
frame 
OVERALL SIZE 
OVERALL SIZE 
B 
DOOR LEAF SIZE 
B’ 
A 
A’ 
OVERALL SIZE 
DOOR 1 LEAF SIZE 
C7DS Model 
Standard Measurements 
16
FIRE RATED AND ACOUSTIC DOORSET–SINGLE LEAF EI2 60-90 C5 FONO-TURIA 
Fono-Turia doorset model combines the 
characteristics of a Fire Doorset with the acoustic 
insulation. 
The Fono-Turia is fire rated doorset, single leaf, 
with steel frame, assembled without welding and 
designed to resist against the fire and to protect 
against the noise. 
This doorset is tested and certified in accordance 
with EN-1634-1: 2000, EN ISO 140-3:1995, EN 
1191:2000. 
Resistencia 
al Fuego 
EI2 60 
EI2 90 
· GALVANISED 
+Antifinger-print 
Protection 
Durabilidad 
Autocierre 
· Stainless 
Steel 
· Other RAL 
to select 
· WHITE 
prelacquered 
9010 
Aislamiento 
Acústico 
C5 
33 dB 
34 dB 
35 dB 
17
Technical Characteristics - FONO-TURIA Doorset 
40 
21.5 
1.2 
CS5 Model (Optional) 
48 
68 
10 
10 
72.5 
10 
Rubber seal 
Intumescent Seal 
Sheet Galvanised steel 
+antifinger-print protection 
What is the ANTIFINGER-PRINT 
PROTECTION? 
The Antifinger finish is a 
clear prime as a supplement 
over the galvanised. 
Allow the doorset 
to be painted 
directly, without 
the need of 
a primar. 
3 advantages 
Provide a 
greater 
anti-corrosive 
protection. 
Aspect is grey, 
transparent, 
homogeneous 
and not oily. 
The frame is also equipped with an intumescent graphite joint 20x3 
mm and a rubber seal onto the frame perimeter to provide the acoustic 
insulation required. 
Steel anchor 
Lock Exploded view 
of the hinge 
Coverplates 
Lever Handles 
EI2 60 35 dB, without vision panel 
EI2 60 33 dB, maximum vision panel 400x500 
RF 60 35 dB, maximum vision panel with double 
glass 200x200 
EI2 90 35 dB, without vision panel 
EI2 90 34 dB, maximum vision panel 400x500 
RF 90 35 dB, maximum vision panel with double 
glass 200x200 
Automatic threshold CS5 Frame Brick to Brick Internal frame size Door leaf size Overall size 
Model Ancho Alto Ancho Alto Ancho Alto Ancho Alto 
FT 800 x 2050 800 2050 780 2068 700 2000 836 2068 
FT 900 x 2050 900 2050 880 2068 800 2000 936 2068 
FT 1000 x 2050 1000 2050 1080 2068 900 2000 1036 2068 
FT 1100 x 2050 1100 2050 1180 2068 1000 2000 1136 2068 
Measurements in millimetres. 
Leaf Frame 
Its STRUCTURE consists of two non-welded 0’8 mm thick galvanised 
steel sheets. Its interior is filled with a combination of insulated 
materials such as rockwool and plasterboard. The doorset is 63 mm 
thick, is eqquiped with an automatic threshold. 
The door is mounted onto a CS5 FRAME made of 1’5 mm thick 
galvanised steel. There are galvanised steel anchors on each side, 
allowing the frame to be installed in brickwork, or screwed onto a sub-frame. 
Fono-Turia range 
Standard Measurements 
The doorset is equipped with 3 HINGES own manufacturing of 3 mm 
thick screwed onto the leaf and assembled to the frame. Certified CE 
Mark according to EN-1935. 
The LOCKING SYSTEM includes a mortice lock of one-point locking 
system with CE Mark according to EN-12209:2007. The system also 
comprises a 35x35 brass cylinder with keys. 
The HANDLE SYSTEM included in the standard range comprises two 
lever handles made of a highly-resistant material, coverplates and 
backplates, also made of the same material, with key-holes on both 
sides. 
To provide an ACOUSTIC INSULATION, rubber seals are incorporated 
onto the leaf: one of black rubber 15x3 mm and another one of vinyl 
which is activated automatically when the door closes. 
18
2 mm 
ABRASION 
RESISTANT 
SCRATCH 
RESISTANT 
IMPACT 
RESISTANT 
FIRE RATED DOORSET 1 & 2 LEAVES SIGMA 
Sigma doorset model combines the characteristics of 
the Fire Doorset with the aesthetics and resistance of 
a Formica Laminate door. 
In close collaboration with Formica we have produced 
a 2 mm High Pressure Formica Laminate, ideal for 
this type of vertical application. 
There is no other doorset in the market that has a 
Laminate of this thickness as practically all doors that 
use a Formica covering have a standard thickness of 
0.7 mm. 
Not only does the aesthetics of this Formica 
covering differ to that of the traditional Fire 
Door but it also provides strong resistance against 
scratching, abrasion and impact, without the 
need of later maintenance. 
EI2 30 C5 EI2 90 C5* 
EI2 60 C5 EI2 120 C5* 
*Only 1 leaf 
19
Office 
Segment 
School 
Segment 
Hotel 
Segment 
Hospital 
Segment 
RAL 9003 
F 2255 
RAL 1019 
K 1181 
RAL 1019 
F 3050 
RAL 7037 
F 1484 
RAL 7011 
K 2020 
RAL 8028 
K 1834 
RAL 1007 
K3209 
RAL 1037 
K 3210 
RAL 3003 
F 7845 
RAL 3004 
F 6902 
RAL 3005 
K 2046 
RAL 4005 
F 0233 
RAL 4006 
F5346 
RAL 6033 
K 1326 
RAL 6002 
F 6901 
RAL 6011 
F 7853 
RAL 8025 
F 1062 
RAL8019 
F 6926 
RAL 8022 
F 9012 
RAL 8017 
F 6932 
RAL 5019 
F7884 
RAL 5013 
F 2828 
RAL 5017 
F 7914 
RAL 6027 
F 7846 
RAL 6005 
K 1336 
RAL 8028 
F 5372 
RAL7012 
K 3737 
RAL 7015 
K 3735 
RAL 7015 
K 5583 
RAL 7016 
K 3734 
RAL 8007 
F 2726 
RAL 8007 
K 7604 
RAL 8025 
F 3699 
RAL 8011 
F 3574 
RAL 7016 
F 5477 
Monotony no more ! 
Apart from the standard reference range that we provide, there is a choice of other 
plain colours, woodgrains and patterns within the rest of the Formica range. 
Besides the catalogue range there is also the option of creating a personalised 
design using the DigiForm digital printing. The design and technical characteristics 
of the Laminate would be maintained. 
Customised model 
Sigma consists of four models designed for the Hospital, Hotel, School, 
Bank and Office segments. 
In collaboration with Tesa, we have configured special hardware for the 
Sigma door of Stainless Steel quality. Each doorset model has a different 
configuration with regards to the lever handle and other accessories such 
as stainless steel kickplates to safeguard hospital beds and trolleys, 
stainless steel frames and profiles, hinges, etc…. 
20
Fire Doorset: Monotony no more 
Hospital & Clinics Offices 
Designed for the hospital sector. The frame and door perimeter 
profile is in stainless steel or oven-painted according to the 
client´s choice. 
- Double stainless steel kickplate on the door pan. 
- Stainless steel hinges. 
- Stainless steel lever handles with protection plate. 
Hotels Teaching Insttitutions 
Designed for the hotel segment. Covered normally 
with a woodgrain Laminate, this door has no 
maintenance cost but has the same appearance as 
a wooden door. 
- Certified with hotel locking system. 
Ideal for offices where security is not the only 
important factor but aesthetics as well. 
Designed for the educational sector: universities, institutes, 
nurseries… The frame and perimeter profile is stainless steel 
or oven-painted according to the client´s choice. 
- Stainless steel lever handle with key-hole and protection 
plate. 
21
Technical characteristics - Sigma Doorset 
CROSS-SECTION A-A’ OVERALL SIZE 
OVERALL SIZE 
A 
B B’ 
CROSS-SECTION B-B’ 
DOOR LEAF SIZE 
INTERNAL FRAME SIZE 
ORDER SIZE 
OVERALL SIZE 
A’ 
OVERALL SIZE 
DOOR LEAF SIZE 
INTERNAL FRAME SIZE 
ORDER SIZE 
Measurements in millimetres. 
Contact us for made-to-measure orders. 
CROSS-SECTION B-B’ 
Rubber seal 
(optionall) 
OVERALL SIZE 
OVERALL SIZE 
B B’ 
OVERALL SIZE 
DOOR LEAF SIZE 
INTERNAL FRAME SIZE 
ORDER SIZE 
Retainer 
Rod 
Automatic 
cremone lock with 
CE Mark 
Rod 
Intumescent Seal 
40 
21.5 
1.2 
48 
68 
10 
10 
72.5 
10 
CS5 Model 
CS5 Frame Brick to Brick Internal frame size Door leaf size Overall size 
Model Width Height Width Height Width Height Width Height 
Measurements in millimetres. 
Contact us for made-to-measure orders. 
SI 800 x 
2050 
800 
2050 
780 
2040 
700 
2000 
836 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
SI 900 x 
2050 
900 
2050 
880 
2040 
800 
2000 
936 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
SI 1000 x 
2050 
1000 
2050 
980 
2040 
900 
2000 
1036 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
SI 1100 x 
2050 
1100 
2050 
1080 
2040 
1000 
2000 
1136 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
SI 1200 x 
2050 
1200 
2050 
1180 
2040 
1100 
2000 
1236 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
CS65 Frame Brick to Brick Internal frame size Door leaf size Overall size 
Model Width Height Width Height Width Height Width Height 
2LSI 1200 x 
2050 
1200 
2050 
1180 
2040 
1100 
2000 
1236 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
2LSI 1300 x 
2050 
1300 
2050 
1280 
2040 
1200 
2000 
1336 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
2LSI 1400 x 
2050 
1400 
2050 
1380 
2040 
1300 
2000 
1436 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
2LSI 1500 x 
2050 
1500 
2050 
1480 
2040 
1400 
2000 
1536 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
2LSI 1600 x 
2050 
1600 
2050 
1580 
2040 
1500 
2000 
1636 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
2LSI 1700 x 
2050 
1700 
2050 
1680 
2040 
1600 
2000 
1736 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
2LSI 1800 x 
2050 
1800 
2050 
1780 
2040 
1700 
2000 
1836 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
2LSI 1900 x 
2050 
1900 
2050 
1880 
2040 
1800 
2000 
1936 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
2LSI 2000 x 
2050 
2000 
2050 
1980 
2040 
1900 
2000 
2036 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
2LSI 2100 x 
2050 
2100 
2050 
2080 
2040 
2000 
2000 
2136 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
2LSI 2200 x 
2050 
2200 
2050 
2180 
2040 
2100 
2000 
2236 
2068 
2100 2100 2090 2050 2118 
2150 2150 2140 2100 2168 
Single leaf 
Its Structure consists of two non-welded 0’8 mm thick galvanised steel sheet 
covered with 2 High Pressure Formica Laminate of 2 mm thick. 
This hight quality Formica Laminate is constructed from layers of paper impregnated 
with termoselting synthetic resins and fixed to the steel sheets with contact glue and 
with steel profile against the leaf perimeter edge, oven-painted or in galvanised 
steel, 0’8 mm thick. 
Its interior is filled with a combination of fire-resistant materials (rockwool and 
plasterboard) and steel reinforcements. The door is 69 mm thickness. 
The doorset is equipped with 3 or 4 height-adjustable reversible steel galvanised 
hinges of 3 mm thick, produced in-house. 
The doorset comprises a mortice lock with one point locking system and also a steel 
cylinder with keys. 
The handle system included in the standard range comprises stainless steel lever 
handle and cover-plates. 
The Sigma doorset also includes plastic corner brackets to ensure the rigidity of the 
leaf and frame and maintain the correct door position during the installation. These 
must be removed after installation. 
Double leaf 
The door is mounted onto a CS5 frame made of 1’5 mm thick 
galvanised steel and oven-painted. The frame can also be made of 1’5 
mm thickness stainless steel called CS65 frame model. 
The frame includes a rubber seal to ensure smooth door closure and 
to avoid gaps, an expanding joint not required. 
The frame has 2 mm thick galvanised steel anchors for installation to 
brickwork or to sub-frame. 
A steel sub-frame is recommended for the Sigma door in order to 
prevent incidents during works such as paint, plaster, cement,…. 
22
Fire Rated Meter Doors 
TURIA 
BASIC 
LEX 
TURIA, BASIC & LEX METER DOORS 
E-doors offers you the TURIA fire rated meter doors, 
with the same technical characteristics than TURIA 
doorset, with fire rating certification up to 120 
minutes. 
EI2 30 EI2 90 
EI2 60 EI2 120 
BASIC and LEX fire rated meter doors, with 60 minutes 
fire rating certification, have a special characteristic: they 
are reversible. 
· GALVANISED 
+Antifinger-print 
Protection 
EI2 60 
· Stainless 
Steel 
· Other RAL 
to select 
· WHITE 
prelacquered 
9010 
REVERSIBLE 
· GALVANISED 
+Antifinger-print 
Protection 
· Stainless 
Steel 
· Other RAL 
to select 
· WHITE 
prelacquered 
9010 
23
Fire Rated Meter Doors 
CROSS-SECTION A-A’ 
OVERALL SIZE 
OVERALL SIZE 
A 
CROSS-SECTION B-B’ 
rotection level Index 
degrePe 
IK 10 
B B’ 
A’ 
BRICK TO BRICK SIZE 
INTERNAL FRAME SIZE = BRICK TO BRICK SIZE - 20 
DOOR LEAF SIZE = BRICK TO BRICK SIZE - 100 
OVERALL SIZE = BRICK TO BRICK SIZE + 36 
OVERALL SIZE = BRICK TO BRICK SIZE+36 
DOOR LEAF SIZE = BRICK TO BRICK SIZE - 100 
INTERNAL FRAME SIZE = BRICK TO BRICK SIZE - 20 
EI2 30 EI2 90 
BRICK TO BRICK SIZE 
EI2 60 EI2 120 Standard Measurements 
The following table refers all the allowed sizes of the certificacion in accordance with UNE 1634-1:2001, for each Fire Meter Door. 
The TURIA METER DOOR has the same technical 
characteristics as the other TURIA doorset, except for the 
following: 
- It comprises a CS5 frame closed on all four 
sides. 
- The number of hinges depends of the size of the door, 
with a minimum of 2 hinges. 
- The four sides of the leaf are surrounded by an edge to 
ensure a tight fit in the closed frame. 
The Turia Meter Doors can be manufactured in single or 
double leaf. 
Cyliner with thumb turn 
The standard handle system of the meter door comprises 
a coverplate with key hole on both sides and cylinder 
with thumb turn on lid side. However, any type of opening 
system can be fitted upon request. 
H E I G H T 
rotection level Index 
degrePe 
IP 2.0 
300 400 500 600 700 710 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 
W I D T H 
330 - - - L L L L L L L L L L L L L - - - - 
400 B B B L L L L L L L L L L L L L - - - - 
500 B B B L L L L L L L L L L L L L - - - - 
600 B B B B B L B B B B L L L L L L L L L L 
700 B B B B B L B B B B L L L L L L L L L L 
710 B B B B B B T B T B T B T B T L T L T L T L T L T L T T T T T 
800 B B B B B B T B T B T B T B T L T L T L T L T L T L T T T T T 
900 B B B B B B T B T B T B T B T L T L T L T L T L T L T T T T T 
1000 B B B B B B T B T B T B T B T L T L T L T L T L T L T T T T T 
T Cover by Turia certification L Cover by Lex certification B Cover by Basic certification 
*For more information look the price list. 
24
CROSS-SECTION A-A’ 
OVERALL SIZE 
OVERALL SIZE 
A 
CROSS-SECTION B-B’ 
B B’ 
A’ 
INTERNAL FRAME SIZE / BRICK TO BRICK 
rotection level Index 
degrePe 
rotection level Index 
degrePe 
CROSS-SECTION A-A’ 
OVERALL SIZE 
OVERALL SIZE 
A 
CROSS-SECTION B-B’ 
B B’ 
A’ 
BRICK TO BRICK SIZE 
Basic Hinge 
Key 
Lock 
60 
10 40 10 
1 
23.6 36.4 
19.23 20 
40 
55.6 
15.6 
OVERALL SIZE 
DOOR LEAF SIZE 
OVERALL SIZE 
DOOR LEAF SIZE 
INTERNAL FRAME SIZE / BRICK TO BRICK 
INTERNAL FRAME SIZE 
DOOR LEAF SIZE 
OVERALL SIZE OVERALL SIZE 
DOOR LEAF SIZE 
INTERNAL FRAME SIZE 
BRICK TO BRICK SIZE 
Lex/Turia 
Hinge 
40 
72.5 
21.5 
1.5 
10 
48 
68 
10 
10 
IK 10 
IP 2.0 
REVERSIBLE CS4 Model 
CS5 Model 
REVERSIBLE 
Basic Meter Doors 
Its STRUCTURE comprises two non-welded 
0’5 mm thickness galvanised steel sheets. Its 
interior is filled with a combination of fire-resistant 
materials such as rockwool and plasterboard. 
The door is 38 mm thick. 
The door is equipped with 2 opposite galvanised 
steel HINGES own manufacturing of 2,5 mm 
thickness. These hinges are screwed onto the 
leaf and assembled to the frame. 
This meter door includes steel cam with triangular 
spindle. Not lever handle included. 
The FRAME is our corner frame CS4, assembled 
without welding. It is made of 1 mm galvanised 
steel sheet, with steel galvanised anchors 
allowing the frame to be installed in brickwork. 
The fitting of a rubber seal is optional. 
Lex Meter Doors 
Its STRUCTURE comprises two non-welded 
0’7 mm thick galvanised steel sheets. Its 
interior is filled with a combination of fire-resistant 
materials such as rockwool and plasterboard. 
The door is 62 mm thick. 
The door is equipped with 2 opposite galvanised 
steel HINGES own manufacturing of 2,5 mm 
thickness. These hinges are screwed onto the 
leaf and assembled onto the frame. Certified CE 
Mark in accordance with EN 1935. 
This meter door is equipped with steel cam with 
triangular spindle. Not lever handle included. 
The FRAME is our corner frame CS5, assembled 
without welding. It is made of 1,2 mm galvanised 
steel sheet, with steel galvanised anchors 
allowing the frame to be installed in brickwork. 
The fitting of a rubber seal and intumescent joint 
are optional. 
25
CS5 Frame installation 
According to the installation and place, the sizes of the doorset can be changed. The wall opening (brick to brick size) will be always our 
reference size. 
Anchored Installation corner wall Screwing installation corner wall 
Wall opening = Order size of the doorset. Wall opening = Internal Frame Size 
1 cm 1 cm 
INTERNAL FRAME SIZE 
ORDER SIZE (OR BRICK TO BRICK SIZE) 
Leaf 
Leaf 
Steel 
anchor 
Frame 
Hinge 
INTERNAL FRAME SIZE 
Anchored Installation between walls Tubular frame: screwing installation between walls 
Wall opening = Overall size or External frame size Wall opening = Overall size or External frame size 
OVERALL SIZE (EXTERNAL FRAME SIZE) 
68 DOOR LIFE SIZE / BRICK TO BRICK - 136 68 
CS5 Frame Assembly with Wide Frame 
Supplement 
CS5 Frame 
Hinge 
Leaf 
For 80 to 190 mm 
Supplement 
CS5 Frame 
Leaf 
Hinge 
For 190 to 300 mm 
INTERNAL FRAME SIZE 
The Wide Frame is a supplement which wraps the wall for 80 to 500 mm 
thick. Contact us for other measurements. 
OVERALL SIZE (EXTERNAL FRAME SIZE) / BRICK TO BRICK 
TUBULAR Frame 
26
Installation of the doorset to a sub-frame 
E-doors has developed a sub-frame which helps for the installation of our fire rated doorsets, in plasterboard or brick walls, certified 
EI2’60. This sub-frame has been developed and patented. 
Installation in plasterboard wall with wrapping frame 
The wrapping sub-frame allows the installation of E-doors fire rated doorsets into a plasterboard wall, maintaining its EI2’60 
certification. It has several u-shaped lengtheners, u-shaped beams and u-shaped top legs; that allows to build the plasterboard 
wall once the sub-frame is installed. 
Rockwool 
Plasterboard CS5 Frame 
Sub-frame 
Sub-frame 
Leaf 
Rockwool 
CS5 Frame Plasterboard 
This wrapping sub-frame allows the later installation of a fire rated doorset in a brick wall, maintaining its EI2’60 certification. The 
sub-frame is partially visible and the doorset can be screwed to the sub-frame. 
Plaster the wall 
Plaster the wall 
Plaster the wall 
Installation in brickwall with wrapping frame 
Leaf 
CS5 Frame 
Sub-frame CS5 Frame Sub-frame 
This corner sub-frame allows the installation of a fire rated doorset in a brick wall, maintaining its EI2’60 certification. The sub-frame 
is only visible on the hinges side, therefore the other side has to be filled with concrete. 
Plaster the wall 
Plaster the wall 
Installation in brickwall with corner frame 
Sub-frame 
To fill with 
mortar 
CS5 Frame 
CS5 Frame Sub-frame 
Leaf 
To fill with mortar 
27
With Guide Rail With link arm 
The door closer body is in the frame. The door closer body is in the leaf. The door closer body is inside the leaf. Only 
Concealed Hinge [CH] 
Our Concealed Hinge can be used in all fired rated doors. 
Moderate 
use 
Frequent 
use 
105º [ CH ] 
Intensive 
use 
Concealed 
Accessories 
The door closer is an accessory, usually installed in the top of the door leaf and the top of the frame that allows a controlled closure of the door. 
Panic Device 
Panic bars are often installed on fire-doorsets. This accessory is designed to open the door immediately in case of emergency. The most commonly used bars are 
shown below: 
2000N Model 4000N Model 4001N Model 
For one-point lock single leaf doors. Consists of two panic bars 2000N model. The 
automatic locking system on the inactive leaf is 
a cremone lock, allowing the internal rod to be 
activated with no need for additional installations on 
the leaf and guarantees the locking of the door at 
two points. 
Consists of two panic bars, 2000N model and 2001N 
model. In contrast with the previous one, the locking 
mechanism is installed onto the surface of the leaf. 
Door closer 
When selecting a door closer the following aspects should be taken into consideration: 
• With Mark and the 4th digit of its classification has to be number 1, indicating its capacity 
for fire rated doors. 
• The door closer force will calculated according to width and weight of the door. 
• Door closer frequency use : moderate, frequent or intensive. 
• Installation type : normal, inverted, parallel or reverse… 
available with ECO Multigenius model with 
strength 3-S. 
28
The vision panels accessories are designed to allow the light through without loosing the fire capacity, can be rounds or rectangulars. 
If the doorset is tested according the EN 1634-1 Standard, its glass would be fire with CE Mark, if the contrary it will loose the test validity. 
This glass ensures a high temperature capacity equivalent with door fire resistance EI2. Its thickness will depend on its fire classification test. 
Electro-Magnet 
Delta 
Round 
Porthole 
This mechanism consists of two parts: The electric current through the electro-magnet 
An electro-magnet 
installed on a wall 
Plate screwed 
onto a door 
maintains the door opened, in case of ceasecurrent, 
the leaf is activated so the door closed. 
All the electric-magnets installed have 
EC Mark. 
Door selector 
The mechanism installed onto the upper frame of a double-leaf door makes the active leaf 
closed against the inactive leaf. 
All the door selectors fitted onto fire doorsets have to cumply with EN 1158 
STANDARD and EC Marking. 
30 / 60 90 / 120 
Ø 200 Ø 360 
Turia DH 
Turia DH 
Turia Turia 
400 x 500 633 x 1900 653 x 1900 633 x 750 633 x 750 
EI2 
Rectangulars 
Porthole 
Vision Panels 
Fire Rated Louvers 
The fire intumescent louvers allow the air flow without changing the fire 
resistance capacity. 
These louvers include horizontal intumescent slits with a perimetral 
frame of the same material ensuring the maximum ventilation and 
fire resistance. 
Detail of Intumescent Louver. 
EI2 30 EI2 60 EI2 90 
29
The single-leaf DELTA, VOLTA and TURIA doorset can be delivered on either horizontal or vertical pallets. The characteristics of both packaging 
systems are shown below: 
VERTICAL PALLET DELTA TURIA PREMIUM/SIGMA FONO-TURIA 
Nº of Doors 15 un 13 un 15 un 
Pallet width 0,95* m 
Pallet lenght 1,18 m 
Pallet height 2,27 m approx 
Approx. pallet weight 981* kg 1076* kg 1328* kg 1076* kg 
* Order Reference 900 EI2 60. 
HORIZONTAL PALLET DELTA TURIA / FONO-TURIA 
Nº of Doors 12 un 
Pallet width 0,95* m 
Pallet lenght 2,10 m 
Pallet height 1,10 m approx 
Approx. pallet weight 809* kg 887,6* kg 
* Order Reference 900 EI2 60. 
VERTICAL PALLET TURIA DH SIGMA DH / PREMIUM DH 
Nº of Doors 7 un 
Pallet width 1,75* m 
Pallet lenght 0,79 m 
Pallet height 2,27 m approx 
Approx. pallet weight 991,44* kg 1187,44* kg 
* Order Reference 900 DH 1700 EI2 60. 
Packaging And Weight 
The TURIA DOUBLE LEAF doorset, due to its weight and dimensions, is packed on vertical pallets. The technical characteristics of this packaging 
system are shown below: 
Fire-Doorset Tests 
Fire Rated Louvers 
The Research and Development Department at E-doors is equipped with an oven similar to those found in certified laboratories to carry out fire-resistance 
tests on its doorset. This allows the company to speed up the tests for new designs in order to adapt them to current regulations and to 
the changing needs of the market. 
The own oven where fire-resistance 
tests are carried out. 
Details of two fire-doorsets in the 
oven during a fire-resistance test. 
Detail of the thermocouples 
allowing the control of thermal 
insulation in fire-doorset during a 
fire-resistance test. 
Vertical pallet Horizontal pallet 
Vertical pallet 
30
All our fire-doorsets have been certified by approved laboratories in order to guarantee the fulfilment of the requisites established by 
the regulation of each country. This certification appears on an identification plate which indicates, among other characteristics, the fire-resistance 
and the test number for this certification. The doorset also include one of the labels as shown below: 
rotection level Index 
degrePe 
IK 10 
rotection level Index 
degrePe 
IP 2.0 
ANDREU BARBERA S.L. 
Ciudad de Sevilla, 20 
Pol. Ind. Fuente del Jarro 
46988 Paterna (VALENCIA) 
ESPAÑA 
OC-P/137 0099/CPP/A44/0120 06 
EN 1935 : 2002 (galva) 4 7 5 1 1 3 0 12 
EN 1935 : 2002 (inox) 4 7 5 1 1 4 0 12 
Fire-doorset Certification 
Identification plate Identification labels 
Durability Tests 
All our fire rated doorset have been tested to a Closing Durability Test according the 
EN1191-1 : 2000 Standard. 
All our range of products passed the 200.000 opening and closing cycles, obtaining a C5 
classification. 
CE Mark Hinges without Spring 
The fire-rated Andreu doorset are equipped with new hinges without spring, own 
manufacturing. 
These hinges have been tested and certified by approval laboratories and 
achieve the CE Mark according the EN 1935. 
CE Mark Hinges without Spring 
Guarantee a protection level IK 10, according to the rule UNE EN 50102 “Degrees of protection provided by the material wrapping the 
electrical components against external mechanical hits. (code IK). 
Degree IP classification is obtained after carrying out the test following the rule UNE 20324 and it’s shown with 2 digits. First one, goes from 
0 to 6, is showing the size of the body that the wrapping material is allowing the entrance. For E-doors meter boxes degree 2 indicates 
that they are protected against a body bigger than 12 mm. Second one, goes from 0 to 8, is showing the protection level of the 
equipment inside the meter box against the water entrance. Degree 0 indicates that they don’t have any specific protection against water 
eMnotrreaonvceer., E-doors meter boxes have a Degree IP 2.0. which shows the protection level of the wrapping material against the entrance of 
water and unknown objects. 
The following E-doors meter boxe’s: 
- Fire resistant model Turia 1 and 2 leaves 
- Fire resistant model Lex 
- Fire resistant model Basic 
- Ensambladas 1 and 2 leaves 
- Company meter boxes: model Electro, Vent and Liso 
31
www.e-doors.nl 
CCFI040314

More Related Content

What's hot

Kopane Courts Mixed Use
Kopane Courts Mixed UseKopane Courts Mixed Use
Kopane Courts Mixed UseGrant Hepburn
 
Lynca Meats - Pork Factory - Meyerton - Details 01
Lynca Meats - Pork Factory - Meyerton - Details 01Lynca Meats - Pork Factory - Meyerton - Details 01
Lynca Meats - Pork Factory - Meyerton - Details 01Trevain Bechan
 
Selo Riser Door Systems
Selo Riser Door SystemsSelo Riser Door Systems
Selo Riser Door SystemsLaurie Ker
 
Lynca Meats - Pork Factory - Meyerton - Plan @ Floor Level 01
Lynca Meats - Pork Factory - Meyerton - Plan @ Floor Level 01Lynca Meats - Pork Factory - Meyerton - Plan @ Floor Level 01
Lynca Meats - Pork Factory - Meyerton - Plan @ Floor Level 01Trevain Bechan
 
Lynca Meats - Pork Factory - Meyerton - Details 02
Lynca Meats - Pork Factory - Meyerton - Details 02Lynca Meats - Pork Factory - Meyerton - Details 02
Lynca Meats - Pork Factory - Meyerton - Details 02Trevain Bechan
 
Leaflet Viometaloumin _English version
Leaflet Viometaloumin _English versionLeaflet Viometaloumin _English version
Leaflet Viometaloumin _English versionChristos Vasiliou
 
Pyrostyle Sales Brochure
Pyrostyle Sales BrochurePyrostyle Sales Brochure
Pyrostyle Sales BrochureGavin Evans
 
Morgan Marine GRP Roadside Cabinets & Transformer Housings
Morgan Marine GRP Roadside Cabinets & Transformer HousingsMorgan Marine GRP Roadside Cabinets & Transformer Housings
Morgan Marine GRP Roadside Cabinets & Transformer HousingsThorne & Derrick International
 
Barndoorhardware.com Distributor of ABP Beyerle
Barndoorhardware.com Distributor of ABP BeyerleBarndoorhardware.com Distributor of ABP Beyerle
Barndoorhardware.com Distributor of ABP BeyerleBarn Door Hardware
 
AluFoldDirect e-brochure
AluFoldDirect e-brochureAluFoldDirect e-brochure
AluFoldDirect e-brochureChris Stretten
 
portfolio june 24 finished portfolio
portfolio june 24 finished portfolioportfolio june 24 finished portfolio
portfolio june 24 finished portfolioAndrew Johnson
 
Studbolt Scotland - Full Brochure (Rev1)
Studbolt Scotland - Full Brochure (Rev1)Studbolt Scotland - Full Brochure (Rev1)
Studbolt Scotland - Full Brochure (Rev1)Paul Queen
 
Westbury w-audio
Westbury w-audioWestbury w-audio
Westbury w-audiojeffschork
 
ALVEK SA COMPANY'S PRESENTATION
ALVEK SA COMPANY'S PRESENTATIONALVEK SA COMPANY'S PRESENTATION
ALVEK SA COMPANY'S PRESENTATIONYvos_Katsamenis
 

What's hot (20)

Kopane Courts Mixed Use
Kopane Courts Mixed UseKopane Courts Mixed Use
Kopane Courts Mixed Use
 
Lynca Meats - Pork Factory - Meyerton - Details 01
Lynca Meats - Pork Factory - Meyerton - Details 01Lynca Meats - Pork Factory - Meyerton - Details 01
Lynca Meats - Pork Factory - Meyerton - Details 01
 
Selo Riser Door Systems
Selo Riser Door SystemsSelo Riser Door Systems
Selo Riser Door Systems
 
Lynca Meats - Pork Factory - Meyerton - Plan @ Floor Level 01
Lynca Meats - Pork Factory - Meyerton - Plan @ Floor Level 01Lynca Meats - Pork Factory - Meyerton - Plan @ Floor Level 01
Lynca Meats - Pork Factory - Meyerton - Plan @ Floor Level 01
 
Lynca Meats - Pork Factory - Meyerton - Details 02
Lynca Meats - Pork Factory - Meyerton - Details 02Lynca Meats - Pork Factory - Meyerton - Details 02
Lynca Meats - Pork Factory - Meyerton - Details 02
 
Leaflet Viometaloumin _English version
Leaflet Viometaloumin _English versionLeaflet Viometaloumin _English version
Leaflet Viometaloumin _English version
 
Pyrostyle Sales Brochure
Pyrostyle Sales BrochurePyrostyle Sales Brochure
Pyrostyle Sales Brochure
 
Morgan Marine GRP Roadside Cabinets & Transformer Housings
Morgan Marine GRP Roadside Cabinets & Transformer HousingsMorgan Marine GRP Roadside Cabinets & Transformer Housings
Morgan Marine GRP Roadside Cabinets & Transformer Housings
 
Khóa điện tử hafele
Khóa điện tử hafeleKhóa điện tử hafele
Khóa điện tử hafele
 
OBZOR
OBZOROBZOR
OBZOR
 
Barndoorhardware.com Distributor of ABP Beyerle
Barndoorhardware.com Distributor of ABP BeyerleBarndoorhardware.com Distributor of ABP Beyerle
Barndoorhardware.com Distributor of ABP Beyerle
 
AluFoldDirect e-brochure
AluFoldDirect e-brochureAluFoldDirect e-brochure
AluFoldDirect e-brochure
 
Presskey
PresskeyPresskey
Presskey
 
portfolio june 24 finished portfolio
portfolio june 24 finished portfolioportfolio june 24 finished portfolio
portfolio june 24 finished portfolio
 
Cierra Puertas Abloy
Cierra Puertas AbloyCierra Puertas Abloy
Cierra Puertas Abloy
 
Screen rail
Screen railScreen rail
Screen rail
 
racks and accessories
racks and accessoriesracks and accessories
racks and accessories
 
Studbolt Scotland - Full Brochure (Rev1)
Studbolt Scotland - Full Brochure (Rev1)Studbolt Scotland - Full Brochure (Rev1)
Studbolt Scotland - Full Brochure (Rev1)
 
Westbury w-audio
Westbury w-audioWestbury w-audio
Westbury w-audio
 
ALVEK SA COMPANY'S PRESENTATION
ALVEK SA COMPANY'S PRESENTATIONALVEK SA COMPANY'S PRESENTATION
ALVEK SA COMPANY'S PRESENTATION
 

Similar to Branddeur

chi-commercial-garage-door-buyers-guide
chi-commercial-garage-door-buyers-guidechi-commercial-garage-door-buyers-guide
chi-commercial-garage-door-buyers-guideSean Rogers
 
Booth sc security doors datasheet
Booth sc security doors datasheetBooth sc security doors datasheet
Booth sc security doors datasheetBoothCommercial
 
Gbpresentation20090825 090901005224 Phpapp01
Gbpresentation20090825 090901005224 Phpapp01Gbpresentation20090825 090901005224 Phpapp01
Gbpresentation20090825 090901005224 Phpapp01Goldbrecht USA
 
Baldwin touchscreen deadbolt customer presentation 8 14-19
Baldwin touchscreen deadbolt customer presentation 8 14-19Baldwin touchscreen deadbolt customer presentation 8 14-19
Baldwin touchscreen deadbolt customer presentation 8 14-19Jorge Ikeda
 
Complete steel-door-solutions
Complete steel-door-solutionsComplete steel-door-solutions
Complete steel-door-solutionsabhiram227
 
Hi-Guard Steel Doors Solution, New Delhi, Steel Security Doors
Hi-Guard Steel Doors Solution, New Delhi, Steel Security DoorsHi-Guard Steel Doors Solution, New Delhi, Steel Security Doors
Hi-Guard Steel Doors Solution, New Delhi, Steel Security DoorsIndiaMART InterMESH Limited
 
24 hour emergency car locksmiths brisbane at hareed
24 hour emergency car locksmiths brisbane at hareed24 hour emergency car locksmiths brisbane at hareed
24 hour emergency car locksmiths brisbane at hareedhareed
 
SeiCom catalogue 2023
SeiCom catalogue 2023SeiCom catalogue 2023
SeiCom catalogue 2023Matis Velt
 
Coastal Joinery Hardware - Connected Solutions. October 2014 update
Coastal Joinery Hardware - Connected Solutions.  October 2014 updateCoastal Joinery Hardware - Connected Solutions.  October 2014 update
Coastal Joinery Hardware - Connected Solutions. October 2014 updateCoastal Joinery Hardware
 
Home Elevators in Malayis
Home Elevators in MalayisHome Elevators in Malayis
Home Elevators in Malayiskrishkrishna57
 
Glass Hardware 2015 Catalogue
Glass Hardware 2015 CatalogueGlass Hardware 2015 Catalogue
Glass Hardware 2015 Cataloguesaharaartwork
 
Catalogue Bloxer English
Catalogue Bloxer EnglishCatalogue Bloxer English
Catalogue Bloxer EnglishMorad Shadeed
 
Proposed_Floorplans_Professional Practice_DS_Group-A1@50_Proposed Ground Floor
Proposed_Floorplans_Professional Practice_DS_Group-A1@50_Proposed Ground FloorProposed_Floorplans_Professional Practice_DS_Group-A1@50_Proposed Ground Floor
Proposed_Floorplans_Professional Practice_DS_Group-A1@50_Proposed Ground FloorJermaine Barrett
 

Similar to Branddeur (20)

chi-commercial-garage-door-buyers-guide
chi-commercial-garage-door-buyers-guidechi-commercial-garage-door-buyers-guide
chi-commercial-garage-door-buyers-guide
 
Energy Saving Window
Energy Saving WindowEnergy Saving Window
Energy Saving Window
 
Booth sc security doors datasheet
Booth sc security doors datasheetBooth sc security doors datasheet
Booth sc security doors datasheet
 
Gbpresentation20090825 090901005224 Phpapp01
Gbpresentation20090825 090901005224 Phpapp01Gbpresentation20090825 090901005224 Phpapp01
Gbpresentation20090825 090901005224 Phpapp01
 
Baldwin touchscreen deadbolt customer presentation 8 14-19
Baldwin touchscreen deadbolt customer presentation 8 14-19Baldwin touchscreen deadbolt customer presentation 8 14-19
Baldwin touchscreen deadbolt customer presentation 8 14-19
 
Complete steel-door-solutions
Complete steel-door-solutionsComplete steel-door-solutions
Complete steel-door-solutions
 
Hi-Guard Steel Doors Solution, New Delhi, Steel Security Doors
Hi-Guard Steel Doors Solution, New Delhi, Steel Security DoorsHi-Guard Steel Doors Solution, New Delhi, Steel Security Doors
Hi-Guard Steel Doors Solution, New Delhi, Steel Security Doors
 
24 hour emergency car locksmiths brisbane at hareed
24 hour emergency car locksmiths brisbane at hareed24 hour emergency car locksmiths brisbane at hareed
24 hour emergency car locksmiths brisbane at hareed
 
Platinum
Platinum Platinum
Platinum
 
SeiCom catalogue 2023
SeiCom catalogue 2023SeiCom catalogue 2023
SeiCom catalogue 2023
 
Coastal Joinery Hardware - Connected Solutions. October 2014 update
Coastal Joinery Hardware - Connected Solutions.  October 2014 updateCoastal Joinery Hardware - Connected Solutions.  October 2014 update
Coastal Joinery Hardware - Connected Solutions. October 2014 update
 
Modern Design Inspirations
Modern Design InspirationsModern Design Inspirations
Modern Design Inspirations
 
Home Elevators in Malayis
Home Elevators in MalayisHome Elevators in Malayis
Home Elevators in Malayis
 
Sectional Door System
Sectional Door SystemSectional Door System
Sectional Door System
 
Glass Hardware 2015 Catalogue
Glass Hardware 2015 CatalogueGlass Hardware 2015 Catalogue
Glass Hardware 2015 Catalogue
 
Glass hardware accessories
Glass hardware accessoriesGlass hardware accessories
Glass hardware accessories
 
Rolling shutter
Rolling shutterRolling shutter
Rolling shutter
 
Catalogue Bloxer English
Catalogue Bloxer EnglishCatalogue Bloxer English
Catalogue Bloxer English
 
2013 Safety Letterbox Company Brochure
2013 Safety Letterbox Company Brochure2013 Safety Letterbox Company Brochure
2013 Safety Letterbox Company Brochure
 
Proposed_Floorplans_Professional Practice_DS_Group-A1@50_Proposed Ground Floor
Proposed_Floorplans_Professional Practice_DS_Group-A1@50_Proposed Ground FloorProposed_Floorplans_Professional Practice_DS_Group-A1@50_Proposed Ground Floor
Proposed_Floorplans_Professional Practice_DS_Group-A1@50_Proposed Ground Floor
 

Recently uploaded

Internship report on mechanical engineering
Internship report on mechanical engineeringInternship report on mechanical engineering
Internship report on mechanical engineeringmalavadedarshan25
 
EduAI - E learning Platform integrated with AI
EduAI - E learning Platform integrated with AIEduAI - E learning Platform integrated with AI
EduAI - E learning Platform integrated with AIkoyaldeepu123
 
Work Experience-Dalton Park.pptxfvvvvvvv
Work Experience-Dalton Park.pptxfvvvvvvvWork Experience-Dalton Park.pptxfvvvvvvv
Work Experience-Dalton Park.pptxfvvvvvvvLewisJB
 
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective IntroductionSachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective IntroductionDr.Costas Sachpazis
 
Risk Assessment For Installation of Drainage Pipes.pdf
Risk Assessment For Installation of Drainage Pipes.pdfRisk Assessment For Installation of Drainage Pipes.pdf
Risk Assessment For Installation of Drainage Pipes.pdfROCENODodongVILLACER
 
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)dollysharma2066
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024hassan khalil
 
Artificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxArtificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxbritheesh05
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVRajaP95
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerAnamika Sarkar
 
complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...asadnawaz62
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxwendy cai
 
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfCCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfAsst.prof M.Gokilavani
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girlsssuser7cb4ff
 
Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AIabhishek36461
 
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)Dr SOUNDIRARAJ N
 
Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...VICTOR MAESTRE RAMIREZ
 
DATA ANALYTICS PPT definition usage example
DATA ANALYTICS PPT definition usage exampleDATA ANALYTICS PPT definition usage example
DATA ANALYTICS PPT definition usage examplePragyanshuParadkar1
 

Recently uploaded (20)

Internship report on mechanical engineering
Internship report on mechanical engineeringInternship report on mechanical engineering
Internship report on mechanical engineering
 
EduAI - E learning Platform integrated with AI
EduAI - E learning Platform integrated with AIEduAI - E learning Platform integrated with AI
EduAI - E learning Platform integrated with AI
 
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
 
Work Experience-Dalton Park.pptxfvvvvvvv
Work Experience-Dalton Park.pptxfvvvvvvvWork Experience-Dalton Park.pptxfvvvvvvv
Work Experience-Dalton Park.pptxfvvvvvvv
 
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective IntroductionSachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
 
Risk Assessment For Installation of Drainage Pipes.pdf
Risk Assessment For Installation of Drainage Pipes.pdfRisk Assessment For Installation of Drainage Pipes.pdf
Risk Assessment For Installation of Drainage Pipes.pdf
 
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024
 
Artificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxArtificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptx
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
 
complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptx
 
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfCCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girls
 
Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AI
 
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
 
Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...
 
DATA ANALYTICS PPT definition usage example
DATA ANALYTICS PPT definition usage exampleDATA ANALYTICS PPT definition usage example
DATA ANALYTICS PPT definition usage example
 

Branddeur

  • 1. FIRE DOORSET DELTA VOLTA TURIA TURIA PREMIUM TURIA DOUBLE OPENING SENSE FONO-TURIA SIGMA METER DOORS ACCESSORIES
  • 2. OPENING DOORS TO THE FUTURE E-doors BV Mauritskade 55C 1092 AD Amsterdam 020-2611839 info@e-doors.nl www.e-doors.nl All rights reserved. Total or partial reproduction prohibited. The company reserves the right to make modifications without prior notice. Our state-of-the-art production systems and our excellent work team gives us a competitive edge in an increasingly complex and demanding market. We are specialized in providing new ideas for our customers’ projects, incorporating an added value and a guarantee of quality in each new model. Our quality management system for the design, production and sales processes of all our lines of steel doorset and hardware is certified by the AENOR in accordance with the UNE-EN-ISO 9001:2000 standards. E-doors BV opens new doors to the future. 2
  • 3. OUR FIRE DOOSET Life for your Home Some of the main concerns and obligations for architects and constructors are the planning and construction of safe, habitable buildings. Security begins with prevention and the selection of adequate structural materials and components, such as fire-doorsets, an essential protective element against the destructive force of fire. As a result, the use of fire-doorsets is mandatory in certain locations, in accordance with current regulations. E-doors BV has more than 40 years experience in the development of ever-more advanced technological solutions. The range of fire-doorsets is the fruit of this effort and of our know-how in the manufacture of high-quality steel doors. EI2 t C5 3
  • 4. Index Delta 5 Volta 7 Turia 9 Turia Double Leaf 11 Turia Premium 13 Turia Premium Double Leaf 14 Turia Double Opening Sense 15 Fono-Turia 17 Sigma 19 Meter Doors 23 Accessoires 28 4
  • 5. SINGLE LEAF FIRE RATED DOORSET EI2 60 C5 DELTA Delta model is our most economic fire-door featuring the most advanced technological innovations, and a structure similar to the rest of doorset in the same range. The door is characterized by its easy installation and maintenance. Built and assembled without welding, the doorset is classified in the EI2 60 category, after having passed the tests carried out in an approved laboratory. Available in standard dimensions only. EI2 60 C5 · GALVANISED +Antifinger-print Protection · Other RAL to select · WHITE prelacquered 9010 5
  • 6. Technical Characteristics - Delta Doorset Sheet Galvanised steel +antifinger-print What is the ANTIFINGER-PRINT PROTECTION? The Antifinger-print finish is a clear prime as a supplement over the galvanised. Allow the doorset to be painted directly, without the need of a prime-washer. 3 advantages Provide a greater anti-corrosive protection. Aspect is grey, transparent, homogeneous and not oily. Height-adjustement Exploded view of the hinge Coverplates Lever Handles 40 21.5 1.2 CS5 Model (Optional) 48 68 10 10 72.5 10 Rubber seal Intumescent Seal Steel anchor DOOR OPENING LEFT HAND RIGHT HAND CS5 Frame Brick to Brick Internal frame size Door leaf size Overall size Model Width Height Width Height Width Height Width Height DE 800 x 2050 800 2050 780 2040 700 2000 836 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 DE 900 x 2050 900 2050 880 2040 800 2000 936 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 DE 1000 x 2050 1000 2050 980 2040 900 2000 1036 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 DE 1100 x 2050 1100 2050 1080 2040 1000 2000 1136 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 DE 1200 x 2050 1200 2050 1180 2040 1100 2000 1236 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 Measurements in millimetres. Contact us for made-to-measure orders. Leaf Frame Standard Measurements The HANDLE SYSTEM included in the standard range comprises two lever handles made of a highly-resistant material, coverplates and backplates, also made of the same material, with key-holes on both sides. When installing the frame into a brick wall, always use cement-based mortars and do not use plaster or other derivatives. (Plaster attacks the zinc coating which protects the galvanised steel against corrosion). The CS5 frame can be screwed onto a specially designed galvanised steel SUB-FRAME, which is optional, and allows the easy installation of the door once the construction works are completed (see page 26 et 27). Its STRUCTURE consists of two non-welded 0’7-mm-thick galvanised steel sheet with “antifinger-print” protection. The doorset is also available in pre-lacquered white steel finish. The doorset is equipped with 2 HINGES own manufacturing of 3 mm thickness screwed onto the leaf and assembled to the frame. Certified CE Mark according to EN-1935. A central steel anti-crow bar bolt for improved security is incorporated into the frame. The LOCKING SYSTEM includes a mortice lock of one-point locking system with CE Mark according to EN-12209:2007. The system also comprises a 35x35 brass cylinder with keys. The profile of this doorset is mounted onto a frame called CS5 made of 1’2 mm-thick galvanised steel. An intumescent seal or rubber seal can also be installed even if the door is not equipped with a seal. 3 galvanised steel anchors on each side, allowing the frame to be installed in brickwork, or screwed onto a sub-frame. 6
  • 7. · GALVANISED +Antifinger-print Protection · Stainless Steel · Other RAL to select · WHITE prelacquered 9010 REVERSIBLE SINGLE LEAF FIRE RATED DOORSET EI2 30-60-90 C5 VOLTA The Volta doorset is our most practical fire rated steel doorset essentially characterized by its REVERSIBILITY. This high-quality designed doorset is easily ADAPTABLE, as it can be installed to open either towards the right or the left. The doorset is built and assembled without welding. It is classified as EI2 30-60-90, in accordance with the tests carried out in an approved laboratory. EI2 30 C5 EI2 60 C5 EI2 90 C5 7
  • 8. Technical Characteristics - Volta Doorset Leaf The STRUCTURE consists of two non-welded 0’8 mm thick galvanised steel sheets. The doorset is also available in pre-lacquered Its INTERIOR is filled with a combination of fire-resistant materials. The door is 63 mm thick, with a 16 mm wide and 2mm thickness edge. The door is equipped with 3 height-adjustable HINGES screwed onto the leaf and an automatic locking system. The LOCKING SYSTEM comprises a mortice lock with a one-point cylinder with keys. The HANDLE SYSTEM included in the standard range comprises two handles made of a highly-resistant material, cover-plates and casing, also made of the same material, with key-holes on both sides. CS5 Frame Brick to Brick Internal frame size Door leaf size Overall size Model Width Height Width Height Width Height Width Height VO 800 x 2050 800 2050 780 2031 700 2000 836 2031 VO 900 x 2050 900 2050 880 2031 800 2000 936 2031 VO 1000 x 2050 1000 2050 980 2031 900 2000 1036 2031 VO 1100 x 2050 1100 2050 1080 2031 1000 2000 1136 2031 VO 1200 x 2050 1200 2050 1180 2031 1100 2000 1236 2031 White finish. locking. The system also comprises a 35 x 35 brass DOOR OPENING (reversible) REVERSIBLE LEFT HAND RIGHT HAND CROSS-SECTION A-A’ OVERALL SIZE INTERNAL FRAME SIZE = BRICK TO BRICK - 19 DOOR SIZE = BRICK TO BRICK - 50 BRICK TO BRICK = H OVERALL SIZE A B B’ A’ CROSS-SECTION B-B’ INTERNAL FRAME SIZE = BRICK TO BRICK + 36 DOOR LEAF SIZE = BRICK TO BRICK - 100 OVERALL SIZE = BRICK TO BRICK - 20 BRICK TO BRICK = A Cross-Section of frame (Upper and Lower) 10 31 20 70.1 1.5 11 CS5 Model Rubber seal (Optional) 40 Rubber seal (Optional) 1.5 Intumescent Seal 48 68 10 72.5 10 21.5 10 Intumescent Seal Measurements in millimetres. Contact us for made-to-measure orders. Standard Measurements Frame The doorset is mounted onto a CS5 FRAME made of 1’5 mm thickness galvanized steel. The cross-section of the frame differs according to the width for reversibility purposes. 4 galvanized steel anchors on each side, allowing the frame to be installed in brickwork, or screwed onto a sub-frame. The doorset comprises an expanding graphite joint. The fitting of a rubber seal is optional. 8
  • 9. FIRE RATED DOORSET 1 & 2 LEAVES EI2 30-60-90-120 C5 TURIA The Turia fire-doorset is available in four models: single-leaf, double-leaf, double-leaf asymmetric and meter doors. Characterized by their great versatility, both the frame and the leaf of this range of door are manufactured in different finishes, in accordance with the requirements of specific projects, and incorporate various accessories, many designed exclusively. These doorset fulfill the double function of security and design, and provide effectiveness and adaptability to any architectural setting. EI2 30 C5 EI2 60 C5 EI2 90 C5 EI2 120 C5 · GALVANISED +Antifinger-print Protection · Stainless Steel · Other RAL to select · WHITE prelacquered 9010 9
  • 10. Technical Characteristics - Turia Doorset CROSS-SECTION A-A’ OVERALL SIZE OVERALL SIZE = BRICK TO BRICK SIZE+18 DOOR LEAF SIZE = BRICK TO BRICK SIZE - 50 INTERNAL FRAME SIZE = BRICK TO BRICK SIZE - 10 OVERALL SIZE A B B’ A’ CROSS-SECTION B-B’ OVERALL SIZE = BRICK TO BRICK SIZE + 36 DOOR LEAF SIZE = BRICK TO BRICK SIZE - 100 INTERNAL FRAME SIZE = BRICK TO BRICK SIZE - 20 BRICK TO BRICK SIZE The STRUCTURE of the Turia EI2 30-60-90 consists of two non-welded 0’8 mm thickness galvanised steel sheets. The doorset is 63 mm thick, with a 16 mm wide and 2 mm thickness edge. The EI2 120 Turia doorset is built with 3 galvanised steel sheets, with a “reinforcement” plate on the pan side of the door. Its leaf is 74 mm thick. The doorset is also available in White finish or Stainless steel finish, and other RAL upon request. Its INTERIOR is filled with a combination of fire-resistant materials. The doorset is equipped with 3 steel galvanised HINGES own manufacturing of 3mm thick, screwed onto the leaf and assembled onto the frame. Certified in accordance with EN- 1935 and CE Mark. The LOCKING SYSTEM comprises a mortice lock with one and 3 points (in 1 leaf). Certified CE Mark according to EN 12209:2004. The system also includes a 35x35 or 35x50 (for EI2 120 door) brass cylinder with the keys. The HANDLE SYSTEM included in the standard range comprises two lever handles made of a highly-resistant material, cover-plates and back plates with key holes on both sides. CS5 Model 40 Rubber seal (Optional) 1.5 Intumescent Seal 48 68 10 72.5 10 21.5 10 BRICK TO BRICK SIZE 63 Turia Doorset EI2 30-60-90 OVERALL SIZE = BRICK TO BRICK SIZE+ 36 DOOR LEAF SIZE = BRICK TO BRICK SIZE - 100 INTERNAL FRAME SIZE = BRICK TO BRICK SIZE - 20 BRICK TO BRICK SIZE 74 Turia Doorset EI2 120 CS5 Frame Brick to Brick Internal frame size Door leaf size Overall size Model Width Height Width Height Width Height Width Height TU 800 x Measurements in millimetres. Contact us for made-to-measure orders. 2050 800 2050 780 2040 700 2000 836 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 TU 900 x 2050 900 2050 880 2040 800 2000 936 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 TU 1000 x 2050 1000 2050 980 2040 900 2000 1036 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 TU 1100 x 2050 1100 2050 1080 2040 1000 2000 1136 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 TU 1200 x 2050 1200 2050 1180 2040 1100 2000 1236 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 Leaf 3 points lock Standard Measurements Frame The doorset is mounted onto a CS5 FRAME made of 1’5 mm thickness galvanised steel. 4 galvanised steel anchors on each side, allowing the frame to be installed in brickwork, or screwed onto a sub-frame. The doorset is also equipped with an intumescent seal. The fitting of a rubber seal is optional. A specially designed SUB-FRAME onto which the CS5 frame can be screwed is also available. This sub-frame allows the easy installation of the door once the construction works are completed (see page 15). 10
  • 11. Technical Characteristics - Turia Double Leaf Doorset CROSS-SECTION A-A’ OVERALL SIZE = BRICK TO BRICK SIZE+18 DOOR LEAF SIZE = BRICK TO BRICK SIZE - 50 INTERNAL FRAME SIZE = BRICK TO BRICK SIZE - 10 CROSS-SECTION B-B’ BRICK TO BRICK SIZE OVERALL SIZE OVERALL SIZE A B B’ A’ OVERALL SIZE = BRICK TO BRICK SIZE+ 36 63 ACTIVE LEAF SIZE DOOR LEAF SIZE = BRICK TO BRICK SIZE -100 INTERNAL FRAME SIZE = BRICK TO BRICK SIZE -20 BRICK TO BRICK SIZE = A OVERALL SIZE = BRICK TO BRICK SIZE+ 36 74 ACTIVE LEAF SIZE DOOR LEAF SIZE = BRICK TO BRICK SIZE -100 INTERNAL FRAME SIZE = BRICK TO BRICK SIZE -20 BRICK TO BRICK SIZE = A Measurements in millimetres. Contact us for made-to-measure orders. Turia Doorset EI2 30-60-90 Turia Doorset EI2 120 CS5 Frame Brick to Brick Internal frame size Door leaf size Overall size Model Width Height Width Height Width Height Width Height DH TU 1200 x 2050 1200 2050 1180 2040 1100 2000 1236 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 DH TU 1300 x 2050 1300 2050 1280 2040 1200 2000 1336 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 DH TU 1400 x 2050 1400 2050 1380 2040 1300 2000 1436 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 DH TU 1500 x 2050 1500 2050 1480 2040 1400 2000 1536 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 DH TU 1600 x 2050 1600 2050 1580 2040 1500 2000 1636 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 DH TU 1700 x 2050 1700 2050 1680 2040 1600 2000 1736 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 DH TU 1800 x 2050 1800 2050 1780 2040 1700 2000 1836 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 DH TU 1900 x 2050 1900 2050 1880 2040 1800 2000 1936 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 DH TU 2000 x 2050 2000 2050 1980 2040 1900 2000 2036 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 DH TU 2100 x 2050 2100 2050 2080 2040 2000 2000 2136 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 DH TU 2200 x 2050 2200 2050 2180 2040 2100 2000 2236 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 Retainer Rod Automatic cremone lock with CE Mark Rod Electric slike Electric strike connecting tube. The Double Leaf Turia EI2 120 C5, is similar to the Turia single leaf EI2 120 C5: it’s built with 3 galvanised steel sheets, with a “reinforcement” plate on the pan side. Its leaf is 74 mm thick. This double leaf doorset is also available in white prelaquared finish and stainless steel and for any other finish upon request. The ACTIVE LEAF has the same characteristics as the TURIA model. The interior of the INACTIVE LEAF is the same than its active counterpart, except that it incorporates an automatic cremone lock (instead of the traditional bolt lock system installed on the edge). Standard Measurements This mechanism comprises the following parts: - Retainer in the upper part of the inactive leaf. - Rods fitted into the interior of the inactive leaf. - An automatic closing system for the cremone lock. - 9 mm mortice lock. When the handle of the inactive leaf is activated, the locking mechanism of the door is released, opening the door. This mechanism allows the installation of panic bars without having to install external fasteners, improving appearance and efficiency. The electric stike is certidied for this model in 1 and 2 leaves for 30, 60 and 90 minutes. 11
  • 12. Technical Characteristics – TURIA asymmetric double leaf doorset The Asymmetric Double Leaf Doorset characteristics are exactly the same as a Turia Double Leaf Doorset, except for the width of the active leaf, which differs from that of the inactive leaf. This mechanism also allows for the installation of panic bars. The asymmetry of the Turia double leaf differs according the requirements of each project. TURIA fix panels Fix panels are a solution specially developed by Andreu to cover any space on a site with our standard doorset. The structure is based in Turia doorset and depending on the space, fix panels can be installed above or on the side of the doorset. Moreover, we can produce with or without intermediate frame between the fix panel and the door leaf. In both cases we have them certified EI2 60, according to the standard UNE-EN 1634:2002. Upper and lateral fix panel without intermediate frame CROSS-SECTION A-A’ OVERALL SIZE BRICK TO BRICK SIZE A A’ OVERALL SIZE OVERALL SIZE DOOR LEAF SIZE Upper fix panel TURIA EI2’60 CROSS-SECTION A-A’ OVERALL SIZE (OVERALL DOOR + OVERALL FIXED PANEL) OVERALL FIXED PANEL OVERALL SIZE OVERALL DOORSET OVERALL A FIXED PANEL A’ A A’ OVERALL SIZE (OVERALL DOOR + OVERALL FIXED PANEL) OVERALL SIZE = BRICK TO BRICK SIZE + 18 OVERALL FIXED DOOR Fix panel and door leaf are build with the same frame. In this case, door leaf is in direct contact with the fix panel. This structure is an esthetical and light solution, which is normally used for upper fix panels. Upper fix panel with intermediate frame In this case the fix panel is independent from the doorset, where each one has is own frame. This solution is better for bigger dimensions and it’s the best solution for fix panels with glass. 12
  • 13. FIRE RATED DOORSET 1 & 2 LEAVES EI2 60 C5 TURIA PREMIUM E-doors five-stars Fire-Doorset. Turia Premium door has been developed in order to supply the market with a high level Fire-Doorset thanks to its high mechanical resistance, its wide sturdiness and the variety of finishings and accessories. Turia Premium doorset has 5 stainless steel hinges, a reinforcement plate of 10 mm thickness and a sub-frame as standard. Turia Premium doorset can be installed with the supplied sub-frame, specially designed by Andreu, in a brick wall or plasterboard wall, without loosing the certificate EI2 60 C5. EI2 60 C5 · Stainless Steel · Other RAL to select · GREY RAL 7043 13
  • 14. Technical Characteristics - Turia PREMIUM CS5 Frame Brick to Brick Internal frame size Door leaf size Overall size Model Width Height Width Height Width Height Width Height TUP 800 x 2150 800 2150 780 2140 700 2100 836 2168 TUP 900 x 2150 900 2150 880 2140 800 2100 936 2168 TUP 1000 x 2150 1000 2150 980 2140 900 2100 1036 2168 TUP 1100 x 2150 1100 2150 1080 2140 1000 2100 1136 2168 TUP 1200 X 2150 1200 2150 1180 2140 1100 2100 1236 2168 CROSS-SECTION A-A’ OVERALL SIZE OVERALL SIZE A CROSS-SECTION B-B’ Rubber seal CS5 Model B B’ Intumescent Seal 40 21.5 1.2 48 68 DOOR LEAF SIZE INTERNAL FRAME SIZE BRICK TO BRICK SIZE 10 10 72.5 10 OVERALL SIZE A’ BRICK TO BRICK SIZE INTERNAL FRAME SIZE DOOR LEAF SIZE OVERALL SIZE OVERALL SIZE B B’ CROSS-SECTION B-B’ OVERALL SIZE A A’ OVERALL SIZE = BRICK TO BRICK SIZE+36 ACTIVE LEAF SIZE DOOR LEAF SIZE = BRICK TO BRICK SIZE - 100 INTERNAL FRAME SIZE = BRICK TO BRICK SIZE - 20 BRICK TO BRICK SIZE = A CS5 Frame Brick to Brick Internal frame size Door leaf size Overall size Model Width Height Width Height Width Height Width Height 2L TUP 1200 x 2150 1200 2150 1180 2140 1100 2100 1236 2168 2L TUP 1300 x 2150 1300 2150 1380 2140 1300 2100 1336 2168 2L TUP 1400 x 2150 1400 2150 1480 2140 1400 2100 1436 2168 2L TUP 1500 x 2150 1500 2150 1580 2140 1500 2100 1536 2168 2L TUP 1600 x 2150 1600 2150 1680 2140 1600 2100 1636 2168 2L TUP 1700 x 2150 1700 2150 1780 2140 1700 2100 1736 2168 2L TUP 1800 x 2150 1800 2150 1880 2140 1800 2100 1836 2168 2L TUP 1900 x 2150 1900 2150 1980 2140 1900 2100 1936 2168 2L TUP 2000 x 2150 2000 2150 2080 2140 2000 2100 2036 2168 2L TUP 2100 x 2150 2100 2150 2180 2140 2100 2100 2136 2168 2L TUP 2200 x 2150 2200 2150 2280 2140 2200 2100 2236 2168 Retainer Rod Automatic cremone lock with CE Mark Rod Measurements in millimetres Contact us for made-to-measure orders. Measurements in millimetres Contact us for made-to-measure orders. Single leaf Turia Premium EI2 60 C5 STRUCTURE is based in 3 non-welded and prelacquered antifinger steel plates of 1 mm thickness. The doorset is 75 mm thick and has a lid in his structure; and has an edge of 16 mm wide and 2 mm thick. Its INTERIOR is filled with a combination of fire-resistant materials. The door has 5 stainless steel HINGES of 3 mm thickness. They are made accordingly to our own design and to the norm UNE-EN 1935. Moreover they are CE marked. They are screwed to the leaf and assembled to the frame. The LOCKING SYSTEM comprises a stainless steel mortice lock with one point locking system. It’s also CE marked accordingly to norm UNE-EN 12209:2004. The system also comprises a 35x35 nickel cylinder with keys. The HANDLE SYSTEM included in the standard range comprises a TESA brand stainless steel square cover plate with handle and keyhole, model SENA. The door is mounted onto a CS5 frame made of 1,5 mm thickness galvanized steel. 4 galvanised steel anchors on each side, allowing the frame to be installed in brickwork or screwed onto a sub-frame. The doorset comprises a graphite intumescent seal and a rubber seal. A SUB-FRAME is also comprised, certified and specially designed to screw our CS5 frame. To allow an easy installation once the work is finished. (Look sub-frame chapter). Doble leaf Turia Premium double leave EI2 60’s STRUCTURE is based in 3 non-welded and prelacquered antifinger steel plates of 1 mm thickness. The doorset is 75 mm thick and has a lid in his structure; and has an edge of 16 mm wide and 2 mm thick. The ACTIVE LEAF has the same characteristics than Turia model, excepts its thickness leaf and steel sheat. The INACTIVE LEAF structure is similar to the active leaf, excepts for the automatic cremone lock (instead of the flush bolt). This mechanism has: - Retainer in the top of the inactive leaf. - Rods inside the inactive leaf. - Automatic cremone lock. - 9 mm mortice lock. When the inactive leaf’s handle is moved, the automatic cremone lock is released and the door is opened. The mechanism allows the installation of panic bars without incorporating external rods: which is an improvement of the door’s aesthetics and efficiency. 14
  • 15. TURIA DOUBLE OPENING SENSE · GALVANISED +Antifinger-print Protection DOUBLE LEAVES FIRE RATED DOORSET EI2 60 C5 · Stainless Steel · Other RAL to select · WHITE prelacquered 9010 Turia Double Opening Sense’s STRUCTURE is made with 2 galvanized steel sheets of 0,8 mm thickness, assembled without welding and with the antifinger protection plus the epoxy painting. It’s thickness is 63 mm, with a 16 mm width and 2 mm thickness rebate. Its INSIDE is made with different fire-proof and thermical isolation materials. With 3 HINGES in 3 mm thickness steel, made with our own design, CE marked according to UNE-EN1935: 2002 standard. The hinges are screwed to the leaf and assembled to the frame The frame used in this doorset model is the C7 DS, made with 1 width and 2 jambs from the same model, where are screwed 2 rods of CS5 frame through nuts. This frame has to be filled with concrete during the installation. That’s why the jambs of this frame has been prepared to facilitate the filling. An intumescent seal in graphite is incorporated in the jambs and the width of the frame. C7 DS frame has a lower bar to facilitate the installation of the door, indicating the floor level. EI2 60 C5 15
  • 16. Technical Characteristics -Turia Double Opening Sense Double Opening Sense doorset is similar to a Turia Double Leaf doorset, exception of its Double Opening Sense. This means, that each one of the leaves are opening in a different sense. That’s why this doorset is mostly used in hospitals. DOOR LEAF SIZE C7DS Frame Brick to Brick Door leaf size Overall size Model Width Height Width Height Width Height 2L TU 1800 GADS 1800 2091 1600 2000 1800 2091 2L TU 1900 GADS 1900 2091 1700 2000 1900 2091 2L TU 2000 GADS 2000 2091 1800 2000 2000 2091 2L TU 2100 GADS 2100 2091 1900 2000 2100 2091 2L TU 2200 GADS 2200 2091 2000 2000 2200 2091 2L TU 2300 GADS 2300 2091 2100 2000 2300 2091 Measurements in millimetres. Contact us for made-to-measure orders. CROSS-SECTION A-A’ OPPENING CROSS-SECTION B-B’ Intumescent sealing 100 90 Intumescent Seal 60 40 32 48 80 70 CS5 Frame Double Sense Openning frame OVERALL SIZE OVERALL SIZE B DOOR LEAF SIZE B’ A A’ OVERALL SIZE DOOR 1 LEAF SIZE C7DS Model Standard Measurements 16
  • 17. FIRE RATED AND ACOUSTIC DOORSET–SINGLE LEAF EI2 60-90 C5 FONO-TURIA Fono-Turia doorset model combines the characteristics of a Fire Doorset with the acoustic insulation. The Fono-Turia is fire rated doorset, single leaf, with steel frame, assembled without welding and designed to resist against the fire and to protect against the noise. This doorset is tested and certified in accordance with EN-1634-1: 2000, EN ISO 140-3:1995, EN 1191:2000. Resistencia al Fuego EI2 60 EI2 90 · GALVANISED +Antifinger-print Protection Durabilidad Autocierre · Stainless Steel · Other RAL to select · WHITE prelacquered 9010 Aislamiento Acústico C5 33 dB 34 dB 35 dB 17
  • 18. Technical Characteristics - FONO-TURIA Doorset 40 21.5 1.2 CS5 Model (Optional) 48 68 10 10 72.5 10 Rubber seal Intumescent Seal Sheet Galvanised steel +antifinger-print protection What is the ANTIFINGER-PRINT PROTECTION? The Antifinger finish is a clear prime as a supplement over the galvanised. Allow the doorset to be painted directly, without the need of a primar. 3 advantages Provide a greater anti-corrosive protection. Aspect is grey, transparent, homogeneous and not oily. The frame is also equipped with an intumescent graphite joint 20x3 mm and a rubber seal onto the frame perimeter to provide the acoustic insulation required. Steel anchor Lock Exploded view of the hinge Coverplates Lever Handles EI2 60 35 dB, without vision panel EI2 60 33 dB, maximum vision panel 400x500 RF 60 35 dB, maximum vision panel with double glass 200x200 EI2 90 35 dB, without vision panel EI2 90 34 dB, maximum vision panel 400x500 RF 90 35 dB, maximum vision panel with double glass 200x200 Automatic threshold CS5 Frame Brick to Brick Internal frame size Door leaf size Overall size Model Ancho Alto Ancho Alto Ancho Alto Ancho Alto FT 800 x 2050 800 2050 780 2068 700 2000 836 2068 FT 900 x 2050 900 2050 880 2068 800 2000 936 2068 FT 1000 x 2050 1000 2050 1080 2068 900 2000 1036 2068 FT 1100 x 2050 1100 2050 1180 2068 1000 2000 1136 2068 Measurements in millimetres. Leaf Frame Its STRUCTURE consists of two non-welded 0’8 mm thick galvanised steel sheets. Its interior is filled with a combination of insulated materials such as rockwool and plasterboard. The doorset is 63 mm thick, is eqquiped with an automatic threshold. The door is mounted onto a CS5 FRAME made of 1’5 mm thick galvanised steel. There are galvanised steel anchors on each side, allowing the frame to be installed in brickwork, or screwed onto a sub-frame. Fono-Turia range Standard Measurements The doorset is equipped with 3 HINGES own manufacturing of 3 mm thick screwed onto the leaf and assembled to the frame. Certified CE Mark according to EN-1935. The LOCKING SYSTEM includes a mortice lock of one-point locking system with CE Mark according to EN-12209:2007. The system also comprises a 35x35 brass cylinder with keys. The HANDLE SYSTEM included in the standard range comprises two lever handles made of a highly-resistant material, coverplates and backplates, also made of the same material, with key-holes on both sides. To provide an ACOUSTIC INSULATION, rubber seals are incorporated onto the leaf: one of black rubber 15x3 mm and another one of vinyl which is activated automatically when the door closes. 18
  • 19. 2 mm ABRASION RESISTANT SCRATCH RESISTANT IMPACT RESISTANT FIRE RATED DOORSET 1 & 2 LEAVES SIGMA Sigma doorset model combines the characteristics of the Fire Doorset with the aesthetics and resistance of a Formica Laminate door. In close collaboration with Formica we have produced a 2 mm High Pressure Formica Laminate, ideal for this type of vertical application. There is no other doorset in the market that has a Laminate of this thickness as practically all doors that use a Formica covering have a standard thickness of 0.7 mm. Not only does the aesthetics of this Formica covering differ to that of the traditional Fire Door but it also provides strong resistance against scratching, abrasion and impact, without the need of later maintenance. EI2 30 C5 EI2 90 C5* EI2 60 C5 EI2 120 C5* *Only 1 leaf 19
  • 20. Office Segment School Segment Hotel Segment Hospital Segment RAL 9003 F 2255 RAL 1019 K 1181 RAL 1019 F 3050 RAL 7037 F 1484 RAL 7011 K 2020 RAL 8028 K 1834 RAL 1007 K3209 RAL 1037 K 3210 RAL 3003 F 7845 RAL 3004 F 6902 RAL 3005 K 2046 RAL 4005 F 0233 RAL 4006 F5346 RAL 6033 K 1326 RAL 6002 F 6901 RAL 6011 F 7853 RAL 8025 F 1062 RAL8019 F 6926 RAL 8022 F 9012 RAL 8017 F 6932 RAL 5019 F7884 RAL 5013 F 2828 RAL 5017 F 7914 RAL 6027 F 7846 RAL 6005 K 1336 RAL 8028 F 5372 RAL7012 K 3737 RAL 7015 K 3735 RAL 7015 K 5583 RAL 7016 K 3734 RAL 8007 F 2726 RAL 8007 K 7604 RAL 8025 F 3699 RAL 8011 F 3574 RAL 7016 F 5477 Monotony no more ! Apart from the standard reference range that we provide, there is a choice of other plain colours, woodgrains and patterns within the rest of the Formica range. Besides the catalogue range there is also the option of creating a personalised design using the DigiForm digital printing. The design and technical characteristics of the Laminate would be maintained. Customised model Sigma consists of four models designed for the Hospital, Hotel, School, Bank and Office segments. In collaboration with Tesa, we have configured special hardware for the Sigma door of Stainless Steel quality. Each doorset model has a different configuration with regards to the lever handle and other accessories such as stainless steel kickplates to safeguard hospital beds and trolleys, stainless steel frames and profiles, hinges, etc…. 20
  • 21. Fire Doorset: Monotony no more Hospital & Clinics Offices Designed for the hospital sector. The frame and door perimeter profile is in stainless steel or oven-painted according to the client´s choice. - Double stainless steel kickplate on the door pan. - Stainless steel hinges. - Stainless steel lever handles with protection plate. Hotels Teaching Insttitutions Designed for the hotel segment. Covered normally with a woodgrain Laminate, this door has no maintenance cost but has the same appearance as a wooden door. - Certified with hotel locking system. Ideal for offices where security is not the only important factor but aesthetics as well. Designed for the educational sector: universities, institutes, nurseries… The frame and perimeter profile is stainless steel or oven-painted according to the client´s choice. - Stainless steel lever handle with key-hole and protection plate. 21
  • 22. Technical characteristics - Sigma Doorset CROSS-SECTION A-A’ OVERALL SIZE OVERALL SIZE A B B’ CROSS-SECTION B-B’ DOOR LEAF SIZE INTERNAL FRAME SIZE ORDER SIZE OVERALL SIZE A’ OVERALL SIZE DOOR LEAF SIZE INTERNAL FRAME SIZE ORDER SIZE Measurements in millimetres. Contact us for made-to-measure orders. CROSS-SECTION B-B’ Rubber seal (optionall) OVERALL SIZE OVERALL SIZE B B’ OVERALL SIZE DOOR LEAF SIZE INTERNAL FRAME SIZE ORDER SIZE Retainer Rod Automatic cremone lock with CE Mark Rod Intumescent Seal 40 21.5 1.2 48 68 10 10 72.5 10 CS5 Model CS5 Frame Brick to Brick Internal frame size Door leaf size Overall size Model Width Height Width Height Width Height Width Height Measurements in millimetres. Contact us for made-to-measure orders. SI 800 x 2050 800 2050 780 2040 700 2000 836 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 SI 900 x 2050 900 2050 880 2040 800 2000 936 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 SI 1000 x 2050 1000 2050 980 2040 900 2000 1036 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 SI 1100 x 2050 1100 2050 1080 2040 1000 2000 1136 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 SI 1200 x 2050 1200 2050 1180 2040 1100 2000 1236 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 CS65 Frame Brick to Brick Internal frame size Door leaf size Overall size Model Width Height Width Height Width Height Width Height 2LSI 1200 x 2050 1200 2050 1180 2040 1100 2000 1236 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 2LSI 1300 x 2050 1300 2050 1280 2040 1200 2000 1336 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 2LSI 1400 x 2050 1400 2050 1380 2040 1300 2000 1436 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 2LSI 1500 x 2050 1500 2050 1480 2040 1400 2000 1536 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 2LSI 1600 x 2050 1600 2050 1580 2040 1500 2000 1636 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 2LSI 1700 x 2050 1700 2050 1680 2040 1600 2000 1736 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 2LSI 1800 x 2050 1800 2050 1780 2040 1700 2000 1836 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 2LSI 1900 x 2050 1900 2050 1880 2040 1800 2000 1936 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 2LSI 2000 x 2050 2000 2050 1980 2040 1900 2000 2036 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 2LSI 2100 x 2050 2100 2050 2080 2040 2000 2000 2136 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 2LSI 2200 x 2050 2200 2050 2180 2040 2100 2000 2236 2068 2100 2100 2090 2050 2118 2150 2150 2140 2100 2168 Single leaf Its Structure consists of two non-welded 0’8 mm thick galvanised steel sheet covered with 2 High Pressure Formica Laminate of 2 mm thick. This hight quality Formica Laminate is constructed from layers of paper impregnated with termoselting synthetic resins and fixed to the steel sheets with contact glue and with steel profile against the leaf perimeter edge, oven-painted or in galvanised steel, 0’8 mm thick. Its interior is filled with a combination of fire-resistant materials (rockwool and plasterboard) and steel reinforcements. The door is 69 mm thickness. The doorset is equipped with 3 or 4 height-adjustable reversible steel galvanised hinges of 3 mm thick, produced in-house. The doorset comprises a mortice lock with one point locking system and also a steel cylinder with keys. The handle system included in the standard range comprises stainless steel lever handle and cover-plates. The Sigma doorset also includes plastic corner brackets to ensure the rigidity of the leaf and frame and maintain the correct door position during the installation. These must be removed after installation. Double leaf The door is mounted onto a CS5 frame made of 1’5 mm thick galvanised steel and oven-painted. The frame can also be made of 1’5 mm thickness stainless steel called CS65 frame model. The frame includes a rubber seal to ensure smooth door closure and to avoid gaps, an expanding joint not required. The frame has 2 mm thick galvanised steel anchors for installation to brickwork or to sub-frame. A steel sub-frame is recommended for the Sigma door in order to prevent incidents during works such as paint, plaster, cement,…. 22
  • 23. Fire Rated Meter Doors TURIA BASIC LEX TURIA, BASIC & LEX METER DOORS E-doors offers you the TURIA fire rated meter doors, with the same technical characteristics than TURIA doorset, with fire rating certification up to 120 minutes. EI2 30 EI2 90 EI2 60 EI2 120 BASIC and LEX fire rated meter doors, with 60 minutes fire rating certification, have a special characteristic: they are reversible. · GALVANISED +Antifinger-print Protection EI2 60 · Stainless Steel · Other RAL to select · WHITE prelacquered 9010 REVERSIBLE · GALVANISED +Antifinger-print Protection · Stainless Steel · Other RAL to select · WHITE prelacquered 9010 23
  • 24. Fire Rated Meter Doors CROSS-SECTION A-A’ OVERALL SIZE OVERALL SIZE A CROSS-SECTION B-B’ rotection level Index degrePe IK 10 B B’ A’ BRICK TO BRICK SIZE INTERNAL FRAME SIZE = BRICK TO BRICK SIZE - 20 DOOR LEAF SIZE = BRICK TO BRICK SIZE - 100 OVERALL SIZE = BRICK TO BRICK SIZE + 36 OVERALL SIZE = BRICK TO BRICK SIZE+36 DOOR LEAF SIZE = BRICK TO BRICK SIZE - 100 INTERNAL FRAME SIZE = BRICK TO BRICK SIZE - 20 EI2 30 EI2 90 BRICK TO BRICK SIZE EI2 60 EI2 120 Standard Measurements The following table refers all the allowed sizes of the certificacion in accordance with UNE 1634-1:2001, for each Fire Meter Door. The TURIA METER DOOR has the same technical characteristics as the other TURIA doorset, except for the following: - It comprises a CS5 frame closed on all four sides. - The number of hinges depends of the size of the door, with a minimum of 2 hinges. - The four sides of the leaf are surrounded by an edge to ensure a tight fit in the closed frame. The Turia Meter Doors can be manufactured in single or double leaf. Cyliner with thumb turn The standard handle system of the meter door comprises a coverplate with key hole on both sides and cylinder with thumb turn on lid side. However, any type of opening system can be fitted upon request. H E I G H T rotection level Index degrePe IP 2.0 300 400 500 600 700 710 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 W I D T H 330 - - - L L L L L L L L L L L L L - - - - 400 B B B L L L L L L L L L L L L L - - - - 500 B B B L L L L L L L L L L L L L - - - - 600 B B B B B L B B B B L L L L L L L L L L 700 B B B B B L B B B B L L L L L L L L L L 710 B B B B B B T B T B T B T B T L T L T L T L T L T L T T T T T 800 B B B B B B T B T B T B T B T L T L T L T L T L T L T T T T T 900 B B B B B B T B T B T B T B T L T L T L T L T L T L T T T T T 1000 B B B B B B T B T B T B T B T L T L T L T L T L T L T T T T T T Cover by Turia certification L Cover by Lex certification B Cover by Basic certification *For more information look the price list. 24
  • 25. CROSS-SECTION A-A’ OVERALL SIZE OVERALL SIZE A CROSS-SECTION B-B’ B B’ A’ INTERNAL FRAME SIZE / BRICK TO BRICK rotection level Index degrePe rotection level Index degrePe CROSS-SECTION A-A’ OVERALL SIZE OVERALL SIZE A CROSS-SECTION B-B’ B B’ A’ BRICK TO BRICK SIZE Basic Hinge Key Lock 60 10 40 10 1 23.6 36.4 19.23 20 40 55.6 15.6 OVERALL SIZE DOOR LEAF SIZE OVERALL SIZE DOOR LEAF SIZE INTERNAL FRAME SIZE / BRICK TO BRICK INTERNAL FRAME SIZE DOOR LEAF SIZE OVERALL SIZE OVERALL SIZE DOOR LEAF SIZE INTERNAL FRAME SIZE BRICK TO BRICK SIZE Lex/Turia Hinge 40 72.5 21.5 1.5 10 48 68 10 10 IK 10 IP 2.0 REVERSIBLE CS4 Model CS5 Model REVERSIBLE Basic Meter Doors Its STRUCTURE comprises two non-welded 0’5 mm thickness galvanised steel sheets. Its interior is filled with a combination of fire-resistant materials such as rockwool and plasterboard. The door is 38 mm thick. The door is equipped with 2 opposite galvanised steel HINGES own manufacturing of 2,5 mm thickness. These hinges are screwed onto the leaf and assembled to the frame. This meter door includes steel cam with triangular spindle. Not lever handle included. The FRAME is our corner frame CS4, assembled without welding. It is made of 1 mm galvanised steel sheet, with steel galvanised anchors allowing the frame to be installed in brickwork. The fitting of a rubber seal is optional. Lex Meter Doors Its STRUCTURE comprises two non-welded 0’7 mm thick galvanised steel sheets. Its interior is filled with a combination of fire-resistant materials such as rockwool and plasterboard. The door is 62 mm thick. The door is equipped with 2 opposite galvanised steel HINGES own manufacturing of 2,5 mm thickness. These hinges are screwed onto the leaf and assembled onto the frame. Certified CE Mark in accordance with EN 1935. This meter door is equipped with steel cam with triangular spindle. Not lever handle included. The FRAME is our corner frame CS5, assembled without welding. It is made of 1,2 mm galvanised steel sheet, with steel galvanised anchors allowing the frame to be installed in brickwork. The fitting of a rubber seal and intumescent joint are optional. 25
  • 26. CS5 Frame installation According to the installation and place, the sizes of the doorset can be changed. The wall opening (brick to brick size) will be always our reference size. Anchored Installation corner wall Screwing installation corner wall Wall opening = Order size of the doorset. Wall opening = Internal Frame Size 1 cm 1 cm INTERNAL FRAME SIZE ORDER SIZE (OR BRICK TO BRICK SIZE) Leaf Leaf Steel anchor Frame Hinge INTERNAL FRAME SIZE Anchored Installation between walls Tubular frame: screwing installation between walls Wall opening = Overall size or External frame size Wall opening = Overall size or External frame size OVERALL SIZE (EXTERNAL FRAME SIZE) 68 DOOR LIFE SIZE / BRICK TO BRICK - 136 68 CS5 Frame Assembly with Wide Frame Supplement CS5 Frame Hinge Leaf For 80 to 190 mm Supplement CS5 Frame Leaf Hinge For 190 to 300 mm INTERNAL FRAME SIZE The Wide Frame is a supplement which wraps the wall for 80 to 500 mm thick. Contact us for other measurements. OVERALL SIZE (EXTERNAL FRAME SIZE) / BRICK TO BRICK TUBULAR Frame 26
  • 27. Installation of the doorset to a sub-frame E-doors has developed a sub-frame which helps for the installation of our fire rated doorsets, in plasterboard or brick walls, certified EI2’60. This sub-frame has been developed and patented. Installation in plasterboard wall with wrapping frame The wrapping sub-frame allows the installation of E-doors fire rated doorsets into a plasterboard wall, maintaining its EI2’60 certification. It has several u-shaped lengtheners, u-shaped beams and u-shaped top legs; that allows to build the plasterboard wall once the sub-frame is installed. Rockwool Plasterboard CS5 Frame Sub-frame Sub-frame Leaf Rockwool CS5 Frame Plasterboard This wrapping sub-frame allows the later installation of a fire rated doorset in a brick wall, maintaining its EI2’60 certification. The sub-frame is partially visible and the doorset can be screwed to the sub-frame. Plaster the wall Plaster the wall Plaster the wall Installation in brickwall with wrapping frame Leaf CS5 Frame Sub-frame CS5 Frame Sub-frame This corner sub-frame allows the installation of a fire rated doorset in a brick wall, maintaining its EI2’60 certification. The sub-frame is only visible on the hinges side, therefore the other side has to be filled with concrete. Plaster the wall Plaster the wall Installation in brickwall with corner frame Sub-frame To fill with mortar CS5 Frame CS5 Frame Sub-frame Leaf To fill with mortar 27
  • 28. With Guide Rail With link arm The door closer body is in the frame. The door closer body is in the leaf. The door closer body is inside the leaf. Only Concealed Hinge [CH] Our Concealed Hinge can be used in all fired rated doors. Moderate use Frequent use 105º [ CH ] Intensive use Concealed Accessories The door closer is an accessory, usually installed in the top of the door leaf and the top of the frame that allows a controlled closure of the door. Panic Device Panic bars are often installed on fire-doorsets. This accessory is designed to open the door immediately in case of emergency. The most commonly used bars are shown below: 2000N Model 4000N Model 4001N Model For one-point lock single leaf doors. Consists of two panic bars 2000N model. The automatic locking system on the inactive leaf is a cremone lock, allowing the internal rod to be activated with no need for additional installations on the leaf and guarantees the locking of the door at two points. Consists of two panic bars, 2000N model and 2001N model. In contrast with the previous one, the locking mechanism is installed onto the surface of the leaf. Door closer When selecting a door closer the following aspects should be taken into consideration: • With Mark and the 4th digit of its classification has to be number 1, indicating its capacity for fire rated doors. • The door closer force will calculated according to width and weight of the door. • Door closer frequency use : moderate, frequent or intensive. • Installation type : normal, inverted, parallel or reverse… available with ECO Multigenius model with strength 3-S. 28
  • 29. The vision panels accessories are designed to allow the light through without loosing the fire capacity, can be rounds or rectangulars. If the doorset is tested according the EN 1634-1 Standard, its glass would be fire with CE Mark, if the contrary it will loose the test validity. This glass ensures a high temperature capacity equivalent with door fire resistance EI2. Its thickness will depend on its fire classification test. Electro-Magnet Delta Round Porthole This mechanism consists of two parts: The electric current through the electro-magnet An electro-magnet installed on a wall Plate screwed onto a door maintains the door opened, in case of ceasecurrent, the leaf is activated so the door closed. All the electric-magnets installed have EC Mark. Door selector The mechanism installed onto the upper frame of a double-leaf door makes the active leaf closed against the inactive leaf. All the door selectors fitted onto fire doorsets have to cumply with EN 1158 STANDARD and EC Marking. 30 / 60 90 / 120 Ø 200 Ø 360 Turia DH Turia DH Turia Turia 400 x 500 633 x 1900 653 x 1900 633 x 750 633 x 750 EI2 Rectangulars Porthole Vision Panels Fire Rated Louvers The fire intumescent louvers allow the air flow without changing the fire resistance capacity. These louvers include horizontal intumescent slits with a perimetral frame of the same material ensuring the maximum ventilation and fire resistance. Detail of Intumescent Louver. EI2 30 EI2 60 EI2 90 29
  • 30. The single-leaf DELTA, VOLTA and TURIA doorset can be delivered on either horizontal or vertical pallets. The characteristics of both packaging systems are shown below: VERTICAL PALLET DELTA TURIA PREMIUM/SIGMA FONO-TURIA Nº of Doors 15 un 13 un 15 un Pallet width 0,95* m Pallet lenght 1,18 m Pallet height 2,27 m approx Approx. pallet weight 981* kg 1076* kg 1328* kg 1076* kg * Order Reference 900 EI2 60. HORIZONTAL PALLET DELTA TURIA / FONO-TURIA Nº of Doors 12 un Pallet width 0,95* m Pallet lenght 2,10 m Pallet height 1,10 m approx Approx. pallet weight 809* kg 887,6* kg * Order Reference 900 EI2 60. VERTICAL PALLET TURIA DH SIGMA DH / PREMIUM DH Nº of Doors 7 un Pallet width 1,75* m Pallet lenght 0,79 m Pallet height 2,27 m approx Approx. pallet weight 991,44* kg 1187,44* kg * Order Reference 900 DH 1700 EI2 60. Packaging And Weight The TURIA DOUBLE LEAF doorset, due to its weight and dimensions, is packed on vertical pallets. The technical characteristics of this packaging system are shown below: Fire-Doorset Tests Fire Rated Louvers The Research and Development Department at E-doors is equipped with an oven similar to those found in certified laboratories to carry out fire-resistance tests on its doorset. This allows the company to speed up the tests for new designs in order to adapt them to current regulations and to the changing needs of the market. The own oven where fire-resistance tests are carried out. Details of two fire-doorsets in the oven during a fire-resistance test. Detail of the thermocouples allowing the control of thermal insulation in fire-doorset during a fire-resistance test. Vertical pallet Horizontal pallet Vertical pallet 30
  • 31. All our fire-doorsets have been certified by approved laboratories in order to guarantee the fulfilment of the requisites established by the regulation of each country. This certification appears on an identification plate which indicates, among other characteristics, the fire-resistance and the test number for this certification. The doorset also include one of the labels as shown below: rotection level Index degrePe IK 10 rotection level Index degrePe IP 2.0 ANDREU BARBERA S.L. Ciudad de Sevilla, 20 Pol. Ind. Fuente del Jarro 46988 Paterna (VALENCIA) ESPAÑA OC-P/137 0099/CPP/A44/0120 06 EN 1935 : 2002 (galva) 4 7 5 1 1 3 0 12 EN 1935 : 2002 (inox) 4 7 5 1 1 4 0 12 Fire-doorset Certification Identification plate Identification labels Durability Tests All our fire rated doorset have been tested to a Closing Durability Test according the EN1191-1 : 2000 Standard. All our range of products passed the 200.000 opening and closing cycles, obtaining a C5 classification. CE Mark Hinges without Spring The fire-rated Andreu doorset are equipped with new hinges without spring, own manufacturing. These hinges have been tested and certified by approval laboratories and achieve the CE Mark according the EN 1935. CE Mark Hinges without Spring Guarantee a protection level IK 10, according to the rule UNE EN 50102 “Degrees of protection provided by the material wrapping the electrical components against external mechanical hits. (code IK). Degree IP classification is obtained after carrying out the test following the rule UNE 20324 and it’s shown with 2 digits. First one, goes from 0 to 6, is showing the size of the body that the wrapping material is allowing the entrance. For E-doors meter boxes degree 2 indicates that they are protected against a body bigger than 12 mm. Second one, goes from 0 to 8, is showing the protection level of the equipment inside the meter box against the water entrance. Degree 0 indicates that they don’t have any specific protection against water eMnotrreaonvceer., E-doors meter boxes have a Degree IP 2.0. which shows the protection level of the wrapping material against the entrance of water and unknown objects. The following E-doors meter boxe’s: - Fire resistant model Turia 1 and 2 leaves - Fire resistant model Lex - Fire resistant model Basic - Ensambladas 1 and 2 leaves - Company meter boxes: model Electro, Vent and Liso 31