Technical Book Fire tube steam boilers SG
2
3
1. General Information
2. Competitive Advantages
3. Technical Specifications
4. P&ID
5. Boiler Layout
6. Installation
7. Scope of Supply
8. Appendix 1. Fuel consumption calculation
9. Appendix 2. Thermodynamic characteristics of
saturated steam
10. Appendix 3. STEAM-MATIC SG special executions
11. Appendix 4. BONO ENERGIA product range
STEAM BOILERS STEAM-MATIC - SG
4
STEAM-MATIC SG fire tube steam boilers produce
saturated or superheated steam, with design
pressure range from 12 bar up to 30 bar. Range of
steam production is between 6000 and 25000 Kg/h.
An efficient design, high-quality construction and
an innovative control system guarantee high level
performance and low energy costs.
Models available:
• SG 600: up to 6.000 Kg/h
• SG 800: up to 8.000 Kg/h
• SG 1000: up to 10.000 Kg/h
• SG 1200: up to 12.000 Kg/h
• SG 1500: up to 15.000 Kg/h
• SG 2000: up to 20.000 Kg/h
• SG 2200: up to 22.000 Kg/h
• SG 2500: up to 25.000 Kg/h
Thermal efficiency reaches 95% thanks to the
optimization of heat exchange and by using our
economizer, an equipment which can be fully
integrated into the boiler. Thermal efficiency higher
than 95% may be achieved thanks to special solutions
by Cannon BONO.
Fields of application of STEAM-MATIC SG boilers are:
pulp and paper industry, food & beverage, district
heating, plastics and rubber industry, chemicals and
petrochemical, woodworking, production of building
material, textile industry.
STEAM-MATIC SG boilers are marked
and can be produced according to the most important
and rigorous directives, such as:
- PED Directive 97/23/CE
- Machinery Directive (MD) 2006/42/CE
- Gas Directive 2009/73/EC according to PED
- Low Voltage Directive (LVD) 2006/95/EC
- Electromagnetic Directive 89/336/EEC.
1. GENERAL INFORMATION
Figure 1
Steam boilers STEAM-MATIC SG
5
1 Burner 6 Exhaust Gas Outlet
2 Safety Valves 7 Drain Connection
3 STEAM-MATIC Furnace 8 Fire Tubes of the 2nd Pass (*)
4 Burner Flame 9 Wet Back Water Tubes
5 Level Probes 10 Integrated Economizer (OPTIONAL)
* = the fire tubes of the second pass are mainly covering the same furnace lateral area on both sides, the smoke flow in the drawing is
just for representation purposes.
Figure 2
Steam boiler STEAM-MATIC SG functional diagram
6
• Thermal efficiency up to 95% and higher
Thanks to an optimized heating surface and
to the optional supply of economizers (air or
water preheater).
• Better heat exchanging process
The wide heating surfaces enable a better
heat exchange; these optimal conditions are
granted in each of the tubes of the boiler,
avoiding thermal flow unbalance and thermal
stresses in the structure elements.
• Two passes are better than three
A two passes boiler has a more balanced
heat transfer from the tubes to the water and
less thermal stresses in the metal structure;
moreover the simplicity of construction of a
two passes boiler enables a total accessibility
to the furnace and the tubes for inspection
purposes and ordinary maintenance.
• Bigger water content volume
A bigger water volume gives to the boiler a
better steam supply flexibility and stability of
the steam pressure and water level.
• Bigger furnace volume
This feature permits lower thermal loads in
the structure and better heat exchange, which
avoids structural dilatations and lower values
of the NOx emissions.
• Supply of “turn-key” boiler units
Boiler units are supplied ready for use. The
boiler is supplied with feed water pumps,
burning system (gaseous, diesel or heavy
fuel), electric cabinet with Cannon BONO con-
trol and management system OPTISPARK.
• Customer oriented solutions
Cannon BONO’s technical specialists are ca-
pable of meeting any customer’s request, thus
having the possibility to offer a great variety
of solutions studied specifically for the cus-
tomer’s needs, starting from boiler construc-
tion to type of fuel burned (especially thanks to
our know-how in designing and realizing each
component of the boiler in Cannon BONO fac-
tory).
2. COMPETITIVE ADVANTAGES
Figure 3
Steam boiler STEAM-MATIC SG
Figure 4
Control panel for steam boiler STEAM-MATIC SG
with OPTISPARK control and management system.
7
TWO PASSES ARE BETTER THAN THREE
STEAM-MATIC serie SG combines the competitive advantages of a fully water cooled back side with a symmet-
rical configuration of tubes and plates, ensuring easy inspection operations and greater performance benefits.
The simple boiler design and the full accessibility to the fire tubes, without disassembling the burner or re-
moving accessories (both in the frontal and back smoke chamber), make the STEAM-MATIC SG series the best
solution for any steam need.
STEAM-MATIC SG furnace
A large furnace, combined with an optimized heat transfer, represent the smartest solution for the best pos-
sible thermal exchange conditions across all the tube bundle, avoiding the thermal load umbalance between
the 2nd and the 3rd pass typical of a 3 pass smoke tubes boilers.
Preventing these thermal umbalance conditions means also avoiding dangerous thermal stresses in the
structure of the pressure vessel itself, which are the main cause of cracks and deformations.
Moreover the rear tubes plates are exposed to a uniform thermal load.
An optimized heat transfer
In a 3 pass boiler most of the heat transfer occurs in the 2nd pass, while in the 3rd pass the transfer becomes
negligible and may expose the tubes to corrosion (dew point) phenomena.
All the boilers of our STEAM-MATIC SG serie are equipped with Intensive Radiant Tubes (I.R.T) which promote:
- High thermal exchange also in convection conditions
- Negligible flow friction rate, with consequent modest burner fan power needed
- Optimized heat flow along the entire section of the tubes
- Higher speed of the flue gases even with boiler running at low rate
2. COMPETITIVE ADVANTAGES - OPTIMIZATION
Figure 5
Heat transfer efficiency slope
8
The thermal flow on a three pass boiler is uneven and tends to concentrate in the central area of the smoke
tubes; therefore the heat transfer becomes significantly lower, especially in the third pass.
Easy access to the burner side tubes
The STEAM MATIC SG frontal smoke chamber can be easily reached without burner disassembling, thanks
to the two lateral front hinged doors. This solution allows fast and costless cleaning operations in order to
preserve the optimal smokes tubes conditions.
The rear smoke chamber can be fastly inspected by means of a wide manhole which enables the operator to
completely enter the chamber and inspect the rear end of the smoke tubes.
The position of the tubes themselves, allocated at both sides of the furnace, permits the operator to easily
check their status.
Heat recovery system
STEAM-MATIC boilers may feature a recovery system (Economizer) integrated in the boiler structure, which
can be easily and fully inspected and do not require expensive or bulky additional gas ducts, often necessary
in a 3 pass design.
The economizers can be easily integrated as optional in the existing structure, which is already shaped and
designed to receive them with an easy inserting operation.
Our SG integrated recovery system gives significant fuel savings by increasing the boiler efficiency of 4-5%,
it moreover speeds up combustion in adverse conditions, such as cold furnace or rapid variation of room
temperature. Installation of the air-preheater together with the economizer and other customized solutions
enables STEAM-MATIC SG boiler to reach up to 99% of efficiency.
Figure 6
Efficiency comparison between 2 and 3 smoke passes
9
Easy inspection of the second
pass fire tubes from the rear
smoke chamber
Easy access to the rear
smoke chamber from a wide
manhole
Easy inspection of the
second pass fire tubes from
the frontal smoke chamber
2. COMPETITIVE ADVANTAGES - BOILER CONSTRUCTION
Figure 7
Easy access spots
in a STEAM-MATIC boiler SG
Easy access to the
heat recovery system
10
2. COMPETITIVE ADVANTAGES - AUTOMATIC CONTROL AND
MANAGEMENT SYSTEM FOR INDUSTRIAL BOILER PLANTS
GARC
VPS
Figure 8
Control and management system
OPTISPARK’s interface
Figure 9
Automatic control and management system for in-
dustrial boiler plants OPTISPARK functional scheme.
BONO OPTISPARK is the automatic control and manage-
ment system for industrial boilers and boiler rooms which
ensures:
• CONTINUOUS AND SAFETY OPERATION
• OPERATIVE SAFETY
• ENERGY EFFICIENCY
• LOWER OWNERSHIP COSTS
• INFORMATION AVAILABILITY FOR MAINTENANCE ACTIVI-
TIES
BONO OPTISPARK is applicable to all types of boilers, new
or already operating; it is suitable for any burner and it is in-
terfaceable with any supervisory control and data acquisition
(SCADA) and any distribution control system (DCS).
The system fits any industrial process and district heating.
The human machine interface is user friendly; the touch
screen operator panel is available in two sizes: 5.7’’ and
10.4’’.
GARCGARC
11
BCU
SIL3
Key technical features of OPTISPARK system:
• Integrated Burner Controller BCU - (Burner Control Unit), SIL3 certified
• Burner start-up sequence management, flame protection and gas Valve Proving System
(VPS) in compliance with EN298 and EN1643
• Micrometric Gas/Air Ratio Control (GARC) in compliance with EN 12067/2
• Level regulation up to three elements with steam flow and feed water flow control
• Management of the inverter installed on the feed water pump and on the fan engine to achieve
maximum energy savings and to reduce noise level
• Heat recovery management and energy-saving registration for green benefits achievement
• Integrated management of the pollutant reduction systems to the chimney (very low NOx
emission)
• Oxygen and Carbon Monoxide combustion trim
• Calculation of energy saving and green benefits.
• Continuos emissions monitoring system in compliance with local legislations
• Power load sharing system between more boilers in the same boiler room
• Historical data recording, alerts and notifications via SMS
• Totalization of water and fuel consumption, steam production, boiler and pumps operation
time
• Managemet of deaerators, water treatment system and auxiliary equipment
• LAN port for remote control and supervision
• BONO maintenance and service via Internet or GPRS modem
12
Table 1
Technical specifications and overall dimensions of steam boiler STEAM-MATIC SG. Data are refered to SG models without economizer or air preheater.
The below listed information is generalized to the entire range of models STEAM-MATIC SG, it’s only indicative and may change in accordance with each
final boiler configuration. Additional data and deviations from standard are available on request.
3. TECHNICAL SPECIFICATIONS - STEAM-MATIC SG
TECHNICAL SPECIFICATIONS
Features Unit SG 600 SG 800 SG 1000 SG 1200 SG 1500 SG 2000 SG 2200 SG 2500
Nominal steam
production Kg/h 6000 8000 10000 12000 15000 20000 22000 25000
Design pressure* bar 12 15 18 12 15 18 12 15 18 12 15 18 12 15 18 12 15 18 12 15 12 15
Min.feed water temp. °C 90 90 90 90 90 90 90 90
Thermal efficiency** % 90 89,5 89 90 89,5 89 90 89,5 89 90 89,5 89 90 89,5 89 90 89,5 89 90 89,5 90 89,5
OVERALL DIMENSIONS AND CONNECTIONS
L Lenght mm 7400 7950 8350 8900 9400 10300 11000 12000
W Width mm 3250 3250 3600 3600 3750 3750 3900 4000
H Height mm 2900 2900 3250 3300 3550 3800 3800*** 3800***
N2
Steam
valve
DN 125 125 100 150 125 100 150 150 125 150 150 150 200 150 150 200 200 200 250 200 250 200
PN 16 40 40 16 40 40 16 40 40 16 40 40 16 40 40 16 40 40 16 40 16 40
N4A
N4B
Safety
valve outlet
DN
40/
65
40/
65
40/
65
40/
65
40/
65
40/
65
50/
80
40/
65
40/
65
50/
80
50/
80
40/
65
65/
100
50/
80
50/
80
65/
100
65/
100
50/
80
65/
100
80/
100
65/
100
65/
100
PN
25/
16
25/
16
40/
16
25/
16
25/
16
40/
16
25/
16
25/
16
40/
16
25/
16
25/
16
40/
16
25/
16
25/
16
40/
16
25/
16
25/
16
40/
16
25/
16
25/
16
25/
16
25/
16
N9
Boiler
drain
DN 40 40 40 40 40 40 40 40
PN 16 16 16 16 16 16 16 16
N
18A
18B
Feed water
line****
Ø 3” 3” 4” 4” 4” 5” 5” 6”
N16
Reversal
chamber
drain
DN 32 32 32 32 32 32 32 32
PN 16 16 16 16 16 16 16 16
N15
Heavy fuel
oil inlet
Ø 2” 2” 2”½ 2”½ 2”½ 2”½ 2”½ 2”½
N17
Natural
gas inlet
Ø 3” 4” 4” 4” 5” 5” 5” 6”
N19
Stack
connection
mm 600 600 720 720 800 850 920 920
Empty weight T 17,0 17,8 18,7 20,0 21,0 22,2 23,0 24,3 25,7 26,0 27,6 29,2 32,0 34,2 36,1 38,0 41,4 43,0 39,5 42 40,5 43
Water volume at
level
m3 9,3 10,0 11,0 13,0 17,7 19,0 22,0 36,0
Full water volume m3 12,3 13,3 15,0 18,0 23,5 26,0 29,3 42,0
TOTAL ELECTRIC POWER
Heavy fuel oil
*****
KW 31,3 32,8 34,8 38,8 38,8 42,8 48,8 52,8 52,8 56,8 60,8 64,3 71,1 74,6 78,1 82,6 86,1 101,1 89,0 92,0 101,0
Natural gas or
diesel oil
KW 18,5 20,0 22,0 26,0 26,0 30,0 33,0 37,0 37,0 41,0 45,0 48,5 52,0 55,5 59,0 64,0 67,0 67,0 75,0 78,0 86,0
Standard electric power data: 400 V/50 Hz/ – 3 phases Auxiliaries voltage: 220 V
FUEL CONSUMPTION
Heavy fuel calorific power: 9700 kcal/kg (for actual fuel consumption calculation see Appendix 1).
Diesel fuel calorific power: 10200 kcal/kg (for actual fuel consumption calculation see Appendix 1).
Natural gas calorific power: 8500 kcal/Nm3 (for actual fuel consumption calculation see Appendix 1).
* Design pressure above 18 bar or below 12 bar on request.
** Thermal efficiency at 100% of the load, with water temperature 90 °C. See Figure 13 for more information.
*** Height is calculated without air fan.
**** Connection size depends on feed water pump supplier.
***** Maximum heavy fuel viscosity is 7°E under 50°C temperature. Information about heavy fuel with higher viscosity on request.
13
Figure 10
STEAM-MATIC SG
steam boiler overall dimension.
More detailed information on
request
14
Table 2
Technical specifications and overall dimensions of steam boiler STEAM-MATIC SG ECO. Data are refered to SG models with economizer. The below
listed information is generalized to the entire range of models STEAM-MATIC SG, it’s only indicative and may change in accordance with each final boiler
configuration. Additional data and deviations from standard are available on request.
3. TECHNICAL SPECIFICATIONS - STEAM-MATIC SG ECO (WITH ECONOMIZER)
TECHNICAL SPECIFICATIONS
Features Unit
SG ECO
600
SG ECO
800
SG ECO
1000
SG ECO
1200
SG ECO
1500
SG ECO
2000
SG ECO
2200
SG ECO
2500
Nominal steam
production Kg/h 6000 8000 10000 12000 15000 20000 22000 25000
Design pressure* bar 12 15 18 12 15 18 12 15 18 12 15 18 12 15 18 12 15 18 12 15 12 15
Min.feed water temp. °C 90 90 90 90 90 90 90 90
Thermal efficiency (with
economizer)** % 95 94,5 94 95 94,5 94 95 94,5 94 95 94,5 94 95 94,5 94 95 94,5 94 95 94,5 95 94,5
OVERALL DIMENSIONS AND CONNECTIONS
L Lenght mm 7400 7950 8350 8900 9400 10300 11000 12000
W Width mm 3250 3250 3600 3600 3750 3750 3900 4000
H Height mm 2900 2900 3250 3300 3550 3800 3800*** 3800***
N2 Steam valve
DN 125 125 100 150 125 100 150 150 125 150 150 150 200 150 150 200 200 200 250 200 250 200
PN 16 40 40 16 40 40 16 40 40 16 40 40 16 40 40 16 40 40 16 40 16 40
N4A
N4B
Safety valve
outlet
DN
40/
65
40/
65
40/
65
40/
65
40/
65
40/
65
50/
80
40/
65
40/
65
50/
80
50/
80
40/
65
65/
100
50/
80
50/
80
65/
100
65/
100
50/
80
65/
100
80/
100
65/
100
65/
100
PN
25/
16
25/
16
40/
16
25/
16
25/
16
40/
16
25/
16
25/
16
40/
16
25/
16
25/
16
40/
16
25/
16
25/
16
40/
16
25/
16
25/
16
40/
16
25/
16
25/
16
25/
16
25/
16
N9 Boiler drain
DN 40 40 40 40 40 40 40 40
PN 16 16 16 16 16 16 16 16
N
18A
18B
Feed water
line****
Ø 3” 3” 4” 4” 4” 5” 5” 6”
N16
Reversal
chamber
drain
DN 32 32 32 32 32 32 32 32
PN 16 16 16 16 16 16 16 16
N15
Liquid fuel
inlet
Ø 2” 2” 2”½ 2”½ 2”½ 2”½ 2”½ 2”½
N17
Natural gas
inlet
Ø 3” 4” 4” 4” 5” 5” 5” 6”
N19
Stack
connection
mm 600 600 720 720 800 850 920 920
Empty weight T 17,6 18,4 19,3 20,6 21,6 22,8 24,0 25,3 26,7 27,0 28,6 30,2 33,2 35,4 37,3 39,4 42,8 44,4 40,9 43,4 42 44,5
Water volume at level m3 9,3 10,0 11,0 13,0 17,7 19,0 22,0 36,0
Full water volume m3 12,3 13,3 15,0 18,0 23,5 26,0 29,3 42,0
TOTAL ELECTRIC POWER
Heavy fuel oil ***** KW 35,3 36,8 38,8 38,8 38,8 42,8 48,8 52,8 52,8 56,8 60,8 64,3 71,1 74,6 78,1 82,6 86,1 101,1 89,0 92,0 101,0
Natural gas or
diesel oil
KW 23,0 24,0 26,0 26,0 26,0 30,0 33,0 37,0 37,0 41,0 45,0 48,5 52,0 55,5 59,0 64,0 67,0 67,0 75,0 78,0 86,0
Standard electric power data: 400 V/50 Hz/ – 3 phases Auxiliaries voltage: 220 V
FUEL CONSUMPTION
Heavy fuel calorific power: 9700 kcal/kg (for actual fuel consumption calculation see Appendix 1).
Diesel fuel calorific power: 10200 kcal/kg (for actual fuel consumption calculation see Appendix 1).
Natural gas calorific power: 8500 kcal/Nm3 (for actual fuel consumption calculation see Appendix 1).
* Design pressure above 18 bar or below 12 bar on request.
** Thermal efficiency at 100% of the load, with water temperature 90 °C. See Figure 14 and for more information.
*** Height is calculated without air fan.
**** Connection size depends on feed water pump supplier.
***** Maximum heavy fuel viscosity is 7°E under 50°C temperature. Information about heavy fuel with higher viscosity on request.
15
Figure 11
STEAM-MATIC SG ECO
steam boiler overall dimension.
Boiler is equipped with economizer
for heat recovery.
16
TECHNICAL SPECIFICATIONS
Features Unit
SG PA
600
SG PA
800
SG PA
1000
SG PA
1200
SG PA
1500
SG PA
2000
SG PA
2200
SG PA
2500
Nominal steam
production Kg/h 6000 8000 10000 12000 15000 20000 22000 25000
Design pressure* bar 12 15 18 12 15 18 12 15 18 12 15 18 12 15 18 12 15 18 12 15 12 15
Min.feed water temp. °C 90 90 90 90 90 90 90 90
Thermal efficiency (with
air preheater)** % 92,5 92 91,5 92,5 92 91,5 92,5 92 91,5 92,5 92 91,5 92,5 92 91,5 92,5 92 91,5 92,5 92 92,5 92
OVERALL DIMENSIONS AND CONNECTIONS
L Lenght mm 7150 7650 7900 8400 9200 10.000 *** ***
W Width mm 3000 3000 3250 3250 3600 3.600 *** ***
H
Height (with
air prehe-
ater)
mm 3700 3700 4050 4050 4560 4.560 *** ***
N2 Steam valve
DN 125 125 100 150 125 100 150 150 125 150 150 150 200 150 150 200 200 200 250 200 250 200
PN 16 40 40 16 40 40 16 40 40 16 40 40 16 40 40 16 40 40 16 40 16 40
N4A
N4B
Safety valve
outlet
DN
40/
65
40/
65
40/
65
40/
65
40/
65
40/
65
50/
80
40/
65
40/
65
50/
80
50/
80
40/
65
65/
100
50/
80
50/
80
65/
100
65/
100
50/
80
65/
100
80/
100
65/
100
65/
100
PN
25/
16
25/
16
40/
16
25/
16
25/
16
40/
16
25/
16
25/
16
40/
16
25/
16
25/
16
40/
16
25/
16
25/
16
40/
16
25/
16
25/
16
40/
16
25/
16
25/
16
25/
16
25/
16
N9 Boiler drain
DN 40 40 40 40 40 40 40 40
PN 16 16 16 16 16 16 16 16
N
18A
18B
Feed water
line*****
Ø 3” 3” 4” 4” 4” 5” 5” 6”
N16
Reversal
chamber
drain
DN 32 32 32 32 32 32 32 32
PN 16 16 16 16 16 16 16 16
N15
Heavy fuel
oil inlet
Ø 2” 2” 2”½ 2”½ 2”½ 2”½ 2”½ 2”½
N17
Natural gas
inlet
Ø 3” 4” 4” 4” 5” 5” 5” 6”
N19
Stack
connection
mm 600 600 720 720 800 850 920 920
Empty weight T 18,0 18,8 19,7 21,0 22,0 23,2 24,0 25,3 27,1 27,0 28,6 30,2 35,0 37,2 39,1 40,0 43,4 45,0 41,9 44,4 43 45,5
Water volume at
level
m3 9,3 10,0 11,0 13,0 17,7 19,0 22,0 36,0
Full water volume m3 12,3 13,3 15,0 18,0 23,5 26,0 29,3 42,0
TOTAL ELECTRIC POWER
Heavy fuel oil **** KW 35,3 36,8 38,8 38,8 38,8 42,8 48,8 52,8 52,8 56,8 60,8 64,3 71,1 74,6 78,1 82,6 86,1 101,1 89,0 92,0 101,0
Natural gas or
diesel oil
KW 23,0 24,0 26,0 26,0 26,0 30,0 33,0 37,0 37,0 41,0 45,0 48,5 52,0 55,5 59,0 64,0 67,0 67,0 75,0 78,0 86,0
Standard electric power data: 400 V/50 Hz/ – 3 phases Auxiliaries voltage: 220 V
FUEL CONSUMPTION
Heavy fuel calorific power: 9700 kcal/kg (for actual fuel consumption calculation see Appendix 1).
Diesel fuel calorific power: 10200 kcal/kg (for actual fuel consumption calculation see Appendix 1).
Natural gas calorific power: 8500 kcal/Nm3 (for actual fuel consumption calculation see Appendix 1).
* Design pressure above 18 bar or below 12 bar on request.
** Thermal efficiency at 100% of the load, with water temperature 90 °C.
*** Height is calculated without air fan.
**** Connection size depends on feed water pump supplier.
***** Maximum heavy fuel viscosity is 7°E under 50°C temperature. Information about heavy fuel with higher viscosity on request.
Table 3
Technical specifications and overall dimensions of steam boiler STEAM-MATIC SG PA with air preheater. The below listed information is generalized to
the entire range of models STEAM-MATIC SG PA, it’s only indicative and may change in accordance with each final boiler configuration. Additional data
and deviations from standard are available on request.
3. TECHNICAL SPECIFICATIONS - STEAM-MATIC SG PA (WITH AIR PREHEATER)
17
Figure 12
STEAM-MATIC SG PA
steam boiler overall dimension.
Boiler is equipped with air
preheater for heat recovery.
18
3. TECHNICAL SPECIFICATIONS - THERMAL EFFICIENCY
Figure 14 The coefficient of performance (COP) of the steam boiler STEAM-MATIC equipped with economizer*.
* Load, % = * 100% , with T feed water at 90° C.
Figure 13 The coefficient of performance (COP) of the steam boiler STEAM-MATIC crossed with the load*.
19
The quality of the water constitutes one of the most important factors regarding duration, safety and reliability of the
steam generator and therefore the entire thermal plant.
The “water circuit” elements are essentially comprised of:
• Unpurified water treatment system: treats the waters available, making them suitable for re-integration into the
plant. The most common methods of treatment are: filters, softeners, reverse osmosis plants, demineralizers, etc.
• Thermophysical degaser: it is made up from an accumulation tank where condensate returning from the utilities
and reintegration water converge. Heating takes place inside the degaser by introducing a regulated flow rate of
steam. The purpose of the treatment is to eliminate the gaseous fractions dissolved in the feed water, particularly
considering oxygen.
• Chemical products dosing control unit: it is made up from one or more tanks fitted with manually regulated dosing
pumps, which send the chemical products into the water supply circuit. Some chemical products must be stored in
a tank fitted with stirrer.
• Boiler bottom outlet and surface blowdown: they allow to keep the amount of salts dissolved and the amount of
slurry inside the boiler drum within the envisioned limits. The quantity of the continuous blowdown operations is
tightly linked to the percentage of total solids in the boiler water: the assistance of a laboratory specialized in the
analysis of water can help in defining the real quantity and frequency of blowdown operations necessary to maintain
normal concentrations.
Table 4
Feedwater Quality Requirements
for best STEAM-MATIC SG opera-
tion and preservation
(a) With copper alloys in the system the pH value shall be maintained in the range from 8.7 to 9.2.
(b) With softened water pH value >7.0 - see the manual of the boiler.
(c) If the operating pressure is <1 bar, the max total acceptable hardness should be 0.05 mmol / l.
(d) In order to observe this value at intermitted operation or operation without deareator an oxygen scavenger shall be used.
(e) Organic substances are generally a mixture of several different compounds. The composition of such mixtures and behaviour of their
individual components under the conditions of boiler operation are difficul to predict. Organic substances may be decomposed to form
carbonic acid or other acidic decomposition products which increase the acid conductivity and cause corrosion or deposits. They also
may lead to foaming and/or priming which shall be kept as low as possible.
3. TECHNICAL SPECIFICATIONS - WATER PROPERTIES
PARAMETERS UNIT
FEED WATER PROPERTIES
ACCORDING TO EN 12953
OPERATING PRESSURE (X) bar (= 0,1 MPa) 0,5 < X < 20 X > 20
APPEARANCE /
Clean, free from suspended
solids
DIRECT CONDUCTIVITY AT 25°C μS/cm Not specified
pH VALUE AT 25 °C (a) / > 9,2 (b) > 9,2 (b)
TOTAL HARDNESS (Ca + Mg) mmol/l < 0,01 (c) < 0,01
IRON (Fe) CONCENTRATION mg/l < 0,3 < 0,1
COPPER (Cu) CONCENTRATION mg/l < 0,05 < 0,03
SILICA (SiO2
) CONCENTRATION mg/l Not specified
OXYGEN (O2
) CONCENTRATION mg/l < 0,05 (d) < 0,02
OIL/GREASE CONCENTRATION
(see EN 12953-6)
mg/l < 1 < 1
ORGANIC SUBSTANCES CONCENTRATION / See footnote (e)
20
Figure 15
Boiler room general P&ID. The data processing schemes are standardized to
the entire STEAM-MATIC SG range; further measurements and modifications are
available on-demand.
4. P&ID - STEAM-MATIC SG - BOILER ROOM
SG – P&ID Elements Description
S1 Water Softener
V1 Feed Water / Condensate Tank
V2 Brine Tank
V3 Chemical Dosing Station
SG – P&ID Ancillaries Symbols Meaning
LV Level Valve
LI Level Indicator
FQ Flow Indicator Totaliser
PI Pressure Indicator
21
INSTRUMENTATION SYMBOLS AND
IDENTIFICATION ISA S-5.1
22
SG – P&ID Elements Description
BDS Blowdown system (OPTION)
L1 Chimney (OPTION)
O2 Flue gas oxygen control system (OPTION)
P1 Feed water pump
P2 Second feed water pump (spare) (OPTION)
TDS Automatic TDS control system (OPTION)
Figure 16
STEAM-MATIC SG P&ID. Further
measurements and modifications are
available on-demand.
4. P&ID - STEAM-MATIC SG
SG – P&ID Ancillaries Symbols Meaning
AI Alarm Indicator
AE Alarm Element
AIC Analyzer Indicator Controller
AT Analyzer Transmitter
AV Analyzer Valve
FC Flow Controller
LV Level Valve
LI Level Indicator
LAH Level Alarm High
LAHH Level Alarm High Above LAH
LAL Level Alarm Low
LALL Level Alarm Low Below LAL
LIC Level Indicator Controller
LSL Level Switch Low
LSLL Level Switch Low Below LSL
LSL/H Level Switch Low/High
LSH Level Switch High
LSHH Level Switch High Above LSH
LT Level Transmitter
M Motor
PAH Pressure Alarm High
PAHH Pressure Alarm High Above PAH
PI Pressure Indicator
PIC Pressure Indicator Controller
PSH Pressure Switch High
PSHH Pressure Switch High Above PSH
PSV Pressure Safety Valve
PT Pressure Transmitter
TAH Temperature Alarm High
TE Temperature Element
TI Temperature Indicator
TSH Temperature Switch High
23
SUPPLY LIMIT
CANNON BONO CUSTOMER
INSTRUMENTATION SYMBOLS
AND IDENTIFICATION ISA S-5.1
Functions managed by “OPTISPARK” system
Combustion control system
Instrument air
Interlock - burner shutdown
Burner
OPTION
24
4. P&ID - STEAM-MATIC SG ECO - WITH ECONOMIZER
SG – P&ID Elements Description
E1 Economizer
BDS Blowdown system (OPTION)
L1 Chimney (OPTION)
O2 Flue gas oxygen control system (OPTION)
P1 Feed water pump
P2 Second feed water pump (spare) (OPTION)
TDS Automatic TDS control system (OPTION)
Figure 17
STEAM-MATIC SG ECO (with economizer) P&ID;
further measurements and modifications are available
on-demand.
SG – P&ID Ancillaries Symbols Meaning
AI Alarm Indicator
AE Alarm Element
AIC Analyzer Indicator Controller
AT Analyzer Transmitter
AV Analyzer Valve
FC Flow Controller
LV Level Valve
LI Level Indicator
LAH Level Alarm High
LAHH Level Alarm High Above LAH
LAL Level Alarm Low
LALL Level Alarm Low Below LAL
LIC Level Indicator Controller
LSL Level Switch Low
LSLL Level Switch Low Below LSL
LSL/H Level Switch Low/High
LSH Level Switch High
LSHH Level Switch High Above LSH
LT Level Transmitter
M Motor
PAH Pressure Alarm High
PAHH Pressure Alarm High Above PAH
PI Pressure Indicator
PIC Pressure Indicator Controller
PSH Pressure Switch High
PSHH Pressure Switch High Above PSH
PSV Pressure Safety Valve
PT Pressure Transmitter
TAH Temperature Alarm High
TE Temperature Element
TI Temperature Indicator
TSH Temperature Switch High
25
SUPPLY LIMIT
CANNON BONO CUSTOMER
INSTRUMENTATION SYMBOLS
AND IDENTIFICATION ISA S-5.1
OPTION
Functions managed by “OPTISPARK” system
Combustion control system
Instrument air
Interlock - burner shutdown
Burner
26
4. P&ID - STEAM-MATIC SG PA - WITH AIR PREHEATER
SG – P&ID Elements Description
PA Air preheater
BDS Blowdown system (OPTION)
L1 Chimney (OPTION)
O2 Flue gas oxygen control system (OPTION)
P1 Feed water pump
P2 Second feed water pump (spare) (OPTION)
TDS Automatic TDS control system (OPTION)
Figure 18
STEAM-MATIC SG PA (with air preheater) P&ID;
further measurements and modifications are
available on-demand.
SG – P&ID Ancillaries Symbols Meaning
AI Alarm Indicator
AE Alarm Element
AIC Analyzer Indicator Controller
AT Analyzer Transmitter
AV Analyzer Valve
FC Flow Controller
LV Level Valve
LI Level Indicator
LAH Level Alarm High
LAHH Level Alarm High Above LAH
LAL Level Alarm Low
LALL Level Alarm Low Below LAL
LIC Level Indicator Controller
LSL Level Switch Low
LSLL Level Switch Low Below LSL
LSL/H Level Switch Low/High
LSH Level Switch High
LSHH Level Switch High Above LSH
LT Level Transmitter
M Motor
PAH Pressure Alarm High
PAHH Pressure Alarm High Above PAH
PI Pressure Indicator
PIC Pressure Indicator Controller
PSH Pressure Switch High
PSHH Pressure Switch High Above PSH
PSV Pressure Safety Valve
PT Pressure Transmitter
TAH Temperature Alarm High
TE Temperature Element
TI Temperature Indicator
TSH Temperature Switch High
27
SUPPLY LIMIT
CANNON BONO CUSTOMER
INSTRUMENTATION SYMBOLS
AND IDENTIFICATION ISA S-5.1
OPTION
Functions managed by “OPTISPARK” system
Combustion control system
Instrument air
Interlock - burner shutdown
Burner
TDS
28
Figure 19
Natural gas combustion system P&ID. The data
processing schemes are standardized to the entire
STEAM-MATIC SG range; further measurements
and modifications are available on-demand.
4. P&ID - SG - NATURAL GAS BURNER
SG – P&ID Elements Description
U10 Combustion air fan
U11 Silencer
SG – P&ID Ancillaries Symbols Meaning
BALL Flame alarm low level
BE Flame scanner
BSLL Flame switch low level
BV On/off actuated valve
BZ Electrical igniter
FC Frequency controller
FV Flow valve
M Motor
PAHH Pressure alarm high high
PALL Pressure alarm low low
PCV Pressure control valve
PI Pressure indicator
PSLL Pressure switch low low
VSP Gas leakage test
SUPPLY LIMIT
CANNON BONO CUSTOMER
INSTRUMENTATION SYMBOLS
AND IDENTIFICATION ISA S-5.1
OPTION
Functions managed by “OPTISPARK” system
Combustion control system
Burner management system
Instrument air
Interlock - burner shutdown
Burner
Joint
29
30
Figure 20
Liquid fuel oil combustion system P&ID. The data processing schemes are standardized to the entire
STEAM-MATIC SG range; further measurements and modifications are available on-demand.
4. P&ID - SG - LIQUID FUEL OIL BURNER (HEAVY FUEL OIL AND DIESEL OIL)
SG – P&ID Elements Description
U10 Combustion air fan
U11 Silencer
P10A Fuel oil pump
P10B Fuel oil pump (spare) (OPTIONAL)
E10 Fuel oil preheater
SG – P&ID Ancillaries Symbols Meaning
BALL Flame alarm low levef PALL Pressure alarm low low
BE Flame scanner PCV Pressure control valve
BSLL Flame switch low level PI Pressure indicator
BV On/off actuated valve PSLL Pressure switch low low
BZ Electrical igniter TAL Temperature alarm low
FC Frequency controller TSL Temperature switch low
FV Flow valve TIC Temperature indicator controller
HV Hand valve TE Thermoelement
M Motor
Functions managed by
“OPTISPARK” system
Combustion control system
(managed by “OPTISPARK”)
Burner management system
Interlock - burner shut down
Burner
Autocleaner strainer
Filter “Y” type
Condensate drain
Sight glass
Instrument air (MIN 5 bar - MAX 7)
SUPPLY LIMIT
CANNON BONO CUSTOMER
INSTRUMENTATION SYMBOLS
AND IDENTIFICATION ISA S-5.1
OPTION
31
32
Figure 21
The data processing schemes are standardized to the entire STEAM-MATIC SG
range; further measurements and modifications are available on-demand.
4. P&ID - SG - NATURAL GAS + LIQUID FUEL OIL BURNER
SG – P&ID Elements Description
U10 Combustion air fan
U11 Silencer
P10A Fuel oil pump
P10B Fuel oil pump (spare) (OPTIONAL)
E10 Fuel oil preheater
Functions managed by
“OPTISPARK” system
Combustion control system
(managed by “OPTISPARK”)
Burner management system
Interlock - burner shut down
Burner
Joint
Autocleaner strainer
Filter “Y” type
Condensate drain
Sight glass
Instrument air (MIN 5 bar - MAX 7)
SUPPLY LIMIT
CANNON BONO CUSTOMER
INSTRUMENTATION SYMBOLS
AND IDENTIFICATION ISA S-5.1
OPTION
SG – P&ID Ancillaries Symbols Meaning
BALL Flame alarm low levef PCV Pressure control valve
BE Flame scanner PI Pressure indicator
BSLL Flame switch low level PAHH Pressure alarm high high
BV On/off actuated valve PSLL Pressure switch low low
BZ Electrical igniter TAL Temperature alarm low
FC Frequency controller TSL Temperature switch low
FV Flow valve TIC Temperature indicator controller
HV Hand valve TE Thermoelement
M Motor VSP Gas leakage test
PALL Pressure alarm low low
33
34
5. BOILER LAYOUT - BOILER ROOM
Figure 22
A sample installation
of a SG STEAM-MATIC
inside a boiler room,
plan view
4
1
2
8002500
15001500
min.800450
600
1500
350
* *
**
15005600
5
prof.Z
20x3
Round bar 10
Flat bar 80X8
Chequered plate
elev. 0.0
every ~2 mt.
500
650
35
1 Steam Boiler SG
2 Water-condensate storage tank
3 Structure supporting tank
4 Feed water treatment unit
5 Steam header
6 Chimney
Figure 23
A sample installation of a SG
STEAM-MATIC inside a boiler
room, front view
3
1002500min.
min.1500
100
710
500
min.2000*
1
2
4
6
36
6. INSTALLATION
“Steam-Matic” generator is shipped ready to operate after a fire test in our factory. For installation local State
regulation must be observed. Examine the boiler on arrival to control if it has suffered any damage during
transport. Any damage should be notified to the carrier. The “Steam-Matic” boiler should be placed on a well
leveled concrete floor.
Minimum clearance must be allowed:
- rear side min : 1,5 m. for inspection
- front side min : sufficient distance for tube cleaning and burner extraction
- left side min : 1,5 m. to allow auxiliaries control
- right side min : 0,8 m. for inspection
The boiler room will be kept clean and well ventilated (indicatively 1 m3 per 1 MW of thermal capacity); a mini-
mum of two opening is required to provide sufficient air for the burner and avoid excessive room temperature.
Flooring
The generator must rest on a strong and levelled floor, the floor slab must be dimensioned to support spe-
cific loads up to 25 N/cm2 and to support the total weight of the generator and its accessories in the full load
condition.
The following connections are required.
Boiler piping
- Steam line to the boiler valve
- Safety valves piped to atmosphere with the same diameter as the
safety valves outlet and with adeguate supports to prevent
stress on valves.
- Bottom and surface blowdown connection piped a drain flash tank
- Water column and sight glass drain piped for blowdown
Flue gas outlet
The generator is supplied with carbon steel counterflange on the fumes exhaust connection, which the in-
staller can use to weld the fumes pipe or the vertical flue.
The fumes connection is dimensioned to support the weight of the flue overlaying for a maximum height of 10
metres from the floor surface (considering the flue pipe realised in steel with thickness of 6 mm). Horizontal
loads and moments must be avoided. For applications that do not lie within the previously described cases,
consult the Bono Energia Technical Dept.
Steam connection
It shall connect the steam main valve to the steam header.
The piping must allows the thermal expansions in order to avoid stress on the valve.
If the utilities pressure is less than the generator operating pressure or if a constant pressure is required it is
necessary to install a reducing valve provided with by-pass.
37
Water and condensate piping
The water tank receives the condensate and treated water. The float valve controls the treated water inlet; up-
stream the float valve it is advisable to install an gate valve to allow removal of float valve for maintenance pur-
poses. In the tank upper section there are the vent and the condensate flanges. The over flow and blowdown
connections are placed on the tank too. A filter is installed on the feed water pump suction side to pro¬tect the
pump. The pipe must be as straight as possible. The height of the feed tank must assure the necessary head
to a¬void pump cavitation and consequent insufficient water feed.
Oil piping (if any)
The main tank must be installed according to the Local Authority Specification.
It is necessary to heat the oil on the tank outlet to facilitate the pumping during cold seasons.
The pre-heating temperature is about 40-60°C.
Electrical tracing of heavy fuel oil lines is required to keep the oil at constant temperature while pumped.
Safety valves
Safety valve discharge has to be vented to atmosphere with a tube of same diameter than valve outlet at least
following the most direct way.
The discharge pipe must be provided, at its lowest point with a condensate drain pipe and must be adequately
supported and free to expand without stress on the valves.
ELECTRIC POWER CONNECTION
Connect electric line to RST terminals in boiler panel according to wiring diagram.
Check that line voltage is within + 5% of nominal value.
The general 3 phase switch, shall be provided and installed preferably outside the boiler room.
HYDRAULIC TEST
If hydraulic test is required, proceed as follows in order to prepare the generator for the hydraulic test:
- Exclude the safety valves by placing a steel disk with suitable thickness between the flanges and close the
boiler valves.
- Close the pressure-switch on-off cock to prevent any damage to the internal parts.
- Remove the outlet cap from the level indicator and make the connection to the hand pump.
- Fill the generator with purified water using the boiler feed pump. Remember, in the event of a centrifugal
pump, narrow the pump delivery in order to limit motor absorption. As for a single-impeller feed pump, the
delivery valve must be open.
- During the filling phase vent the air through the vent valve until water flows out; then close the vent valve.
- When filling has been completed, make sure that the 3-way cock connected to the boiler manometer is open,
pressurise the boiler with the centrifugal pump and then with the hand pump until the prescribed hydraulic
test pressure is reached.
38
BOILER START UP
Boiler Filling
When filling the boiler, the water must appear just above the normal level (block) in a way to allow successive
expansion when the water itself is heated.
At least one vent valve must be left open during the filling phase to prevent pressurisation of the boiler due to
the effect of the air it contains; the operator must monitor the pressure trend carefully and stop the pump if
any anomalies are detected.
Boiler must be filled slowly, in particular if water is hot, so that no dangerous stress occurs in pressure parts.
If boiler is partially filled, temperature of new water that is introduced shall be not higher or lower than 25 °C
than temperature of water already present in the boiler.
Usually water temperatury should not less than 20°C for filling operation; if temperature is higher than 40°C
filling must be carried out with extreme precautions.
IMPORTANT: drain levels and look at the filling to verify cleanliness and operation. For filling use only wa-
ter with suitable characteristics
Preliminary operations
Before starting the boiler check that all auxiliary devices have been tested.
The following procedure is a summarised list of main controls to be carried out before starting up:
• check water level on level gauges: the level must be 30 mm over the block value
• check level gauges opening drains and looking at refilling
• check regulation valves drains and vents
• check safety valves installation and verify congruence between set point and stamp pressure of valves
• check minimum position of combustion air damper
• check all flanged connections and gaskets presence and check all bolts
• check that the man hole and the inspection hatches are closed with the bolts tightened and the gaskets
in position;
• check that the requested quality of hot water is available
• check all safety logics and interblocks and check all safety instruments
ATTENTION: if any of above checks has negative result do not start up boiler.
6. INSTALLATION
39
STARTING UP
After carrying out above operations boiler can be started up.
Burner operation and combustion shall be controlled during start up; air / fuel ratio shall be set in respect of
flue gas analysis at different loads. CO content shall be limited within local law requirements.
Burner shall be ignited following relevant instructions and with strict respect of safety instructions consider-
ing also of fuel type
Boiler must be at minimum until steam flows from vent valve; from this situation is possible to closo vent valve
and increase pressure.
Pressure shall be increased with burner low load.
ATTENTION: too rapid temperature increase can create dangerous sress conditions
and cause cracks
STEAM PRODUCTION
When set pressure is reached with boiler at minimum load, load can be increased and control can be set for
automatic operation.
ATTENTION: the system shall be kept continuously controlled until MCR has been reached to verify that no
defects in safety system is present.
NORMAL OPERATION
When boiler begins maximum load production it is necessary to verify normal conditions for continuos eco-
nomical and safe operation. Temperatures, pressure capacities shall be measured with precision and conti-
nuity and shall be compared with design figures; in particular flue gas temperature is directly associated with
efficiency: an increase of this temperature is a decrease of efficiency.
An increase of pressure in combustion air / flue gas system indicate that flue gas channels are dirty and clean-
ing operation is urgently needed.
It is advisable to record all measures on a log book and in particular:
• fuel consumption
• flue gas analysis
• flue gas temperature
• air / flue gas pressure
• operation time and load
• any other useful note necessary to create a databank of the boiler.
40
During boiler operation a particular attention shall be paid to
A) Boiler water level
The normal water level in the boiler must be maintained at all times. If this is too high, water may be dragged
into the steam, thus compromising its purity. If the level is too low, the boiler pipes may overheat or, in ex-
treme cases, break. When in very low conditions, switch the fires off immediately and look for the causes of
this situation before igniting again.
ATTENTION: If level is below minimum stop immediately the burner and in any case do not refill with cold
water the boiler. The furnace may explode immediately.
Levels gauges and switches shall be always perfectly efficient; level gauges shall be drained at any periodical
personnel rotation to verify cleanliness.
Level gauges purge shall be carried out full opening slowly drain cocks and closing them looking at refilling:
if water is drained too slowly repeat operation to purge levels from dirty.
B) Water treatment and continuous blow down (see also Table 4)
The chemical treatment of the feed water, the conditioning of the boiler water and the regulation of the con-
centration of the salts in the boiler water must be set accurately, as soon as the new boiler is used.
Blow down capacity shall be directly connected to total salt concentration in boiler water: periodical chemical
analysis of boiler water are necessary to define exact capacity of blow down
C) Combustion
Efficient combustion is fundamental for good boiler operation: bad combustion can cause the production of
unburned fuels, thus compromising boiler performance along with the formation of carbon deposits on the
inner surfaces of the pipes with consequent dirtying (and further penalisation of performance).
Therefore combustion shall be monitored continuously.
In general good combustion is obtained with perfect air distribution in the burner: the position of the air swirler
shall be correct and checked periodically.
ATTENTION: it is absolutely necessary to respect all instructions of burner manufacturer during start up,
normal operation and shut down of the burner. In particular it is always necessary to purge
combustion chamber (with combustion air) before any burner start-up.
Combustion shall be optimised verifying air /fuel ratio (air excess) at any boiler and burner load. Air excess
measurement can be performed by means of a flue gas oxygen content analysis; too high air excess causes
efficiency reduction.
It is therefore necessary to periodically analyse the fumes released into the flue, in order to verify the correct
maintenance of the operating parameters.
6. INSTALLATION
41
BOILER SHUTDOWN
When the boiler is stopped, the burner and the air fan must be put out of service following the Standards inher-
ent the combustion system used.
Particular attention must be paid to the conditions in which the combustion system is left. When the burner
has been switched off, the air fan must be left in service in order to complete cleaning of the combustion
chamber and eliminate any trace of unburned fuel residues and then stopped.
The boiler must be left to cool down slowly as uniformly as possible. Accelerating cooling of the combustion
chamber by allowing large masses of cold air to pass through the plant could lead to damage of the refractory
materials and useless tensions in the pressurised parts.
Later, when the refractory materials have reached lower temperatures, the use of a small air flow through the
burner will be allowed. At this point, the pressure in the boiler must be left to decrease naturally, without with-
drawing steam or opening the valves. When the pressure has dropped below 1 bar, a vent valve can be opened.
When it is necessary to empty the boiler, boiler water temperature shall be below 100°C before openig boilers
drains.
ATTENTION: before opening drains check if vent valve is opened to avoid vacuum condition in the boiler.
When the boiler has been fully drained inernal inspection can be performed.
42
7. SCOPE OF SUPPLY - STANDARD EQUIPMENT
STANDARD EQUIPMENT - STEAM-MATIC SG
BOILER
PRESSURE VESSEL
Cylindrical furnace fitted with expansion joints up to model SG 1200 (corrugated type from model SG
1500)
Shell equipped with manholes, inspection and cleaning doors, flanged doors, steam outlet branch
Moisture separator
Front and rear tube plates dished type, butt-welded to the shell and the furnace
Smoke tubes expanded and welded to the tube plates, internal turbulator system
Flanged connection for self-supporting stack, with counterflange
Water tube reversing chamber with upper and lower headers welded to the rear tube plate
INSULATION AND
EXTERNAL
LAGGING
Insulation of the external casing in mineral wool panels, stainless steel external lagging
BASE Base frame made with iron bars
VALVES AND
ACCESSORIES
Main steam valve (manual)
N.2 Pressure safety valves
Shell blow down valve (surface)
N.2 Level indicators, with shut-off valve
N.2 Shell drain valves
N.2 Reversal chamber blow down valves
Flue gases thermoelement at the stack base
Flue gases sampling point at the stack base
Rear flame sight hole
WATER FEEDING
GROUP
Multi stage centrifugal pump (horizontal design)
On-off valve
Level regulation system with 1 pc. modulating pneumatic valve
Check valve
43
STANDARD EQUIPMENT - STEAM-MATIC SG
BURNING SYSTEM
(modulating
regulation)
Burner box
Flame scanner
Observation port for flame control
Air swirler
Combustion air fan
Burning ignition torch
NATURAL GAS
FUEL (NG)
Natural gas pressure gauge
Internal gas header with multi-nozzle system
N.2 Feeding gas train electrically actuated shut-off valves
Feeding gas electrically actuated regulating valve
N.2 Burning ignition safety solenoid valves
HEAVY FUEL OIL
(HFO)
Fuel pump station, complete with on/off valve
Preheating station steam-electrical thermoregulation system
DIESEL OIL (DO) Fuel pump station, complete with on/off gate valve
SAFETY AND
CONTROL
EQUIPMENT
FOR THE
BOILER
Burner management system for burner ignition and flame control BMS (safety automatic device)
Safety pressure switch for minimum air combustion pressure
Temperature regulation system (only heavy fuel oil)
Gas leakage test- VPS (only gas fuel)
N.2 Max/min fuel pressure switches
Steam pressure transmitter
Shut-down pressure switch for max steam pressure
Automatic pressure modulating control regulator
Automatic modulating level control regulator
ELECTRIC
WIRING
With flexible conduits and tight terminal fittings for high mechanical resistance and water proof
sealing
ELECTRIC PANEL
Steel cabinet, oven painting, front door, IP54 protection
Power section, main switch and door locking device, magneto-thermal switches to protect each
power user, tropicalized power contactors
Control auxiliary section, ignition and flame control panel, alarms and shut-down logic, alarm
horn contacts, auxiliaries protection fuses
Operators panel, burner START/STOP switch/indicator, feed pump START/STOP switch/indica-
tor, alarms acknowledgement with lamps
TYPEOFFUELAVAILABLE*
* dual fuel burning systems are available (NG + HFO, NG + DO) and include the burning system equipment above listed for each fuel type.
44
7. SCOPE OF SUPPLY - OPTIONAL EQUIPMENT
OPTIONAL EQUIPMENT* - STEAM-MATIC SG
ECONOMISER
(FOR HIGH
EFFICIENCY
UP TO 95%)
Package unit bult-in the front side of the generator structure insulation
Carbon steel tube bundle made of finned tubes and elbows
Set of headers for water inlet and outlet
N.2 Inspection and maintenance upper doors
SET OF
INSTRUMENTS
FOR
ECONOMISER
Vent valves
Drain valve
N.2 Temperature gauge for inlet and outlet temperature
N.2 Shut-off manual valves
N.2 Pressure points
Safety valve
By pass valve (manual)
AIR
PREHEATER
(FOR HIGH
EFFICIENCY
UP TO 92%)
Package unit bult-in the front side of the generator structure
Double vertical carbon steel tubes bank, with flue gases running inside and air running outside the tubes.
N.2 Inspection and maintenance upper doors
SECOND FEED
WATER PUMP AS
SPARE (Installed
on boiler base
frame and
connected to the
boiler skid)
Multi stage centrifugal pump (horizontal design)
On-off valve
Check valve
FEEDING PUMP
SPEED CONTROL
SYSTEM (available
for each pump)
Feeding pump speed control system (drived by electrical inverter)
Feed water pressure control loop
COMBUSTION AIR
FAN SPEED
CONTROL SYSTEM
Electrical inverter
SPARE FUEL PUMP Spare fuel pump (available for liquid fuel burner)
AUTOMATIC
BOILER CONTROL
SYSTEM
«OPTISPARK»
BONO Optispark industrial boilers management and control automatic system
Flue gas oxygen control system with separated probe
Control system of the air/fuel ratio (SRC) and of the supply of oxygen (electric cam)
45
OPTIONAL EQUIPMENT* - STEAM-MATIC SG
«SAFESPARK»
SYSTEM (24 HOUR)
System for 24 hour boiler operating without human presence according to
EN 12953 Directive
N.2 Automatically controlled minimum level probes with periodical test, complete with switch
Automatically controlled high level probes with periodical test, complete with switch
Upgraded photocell, with automatically controlled periodical test
“SAFESPARK”
SYSTEM (72 HOUR)
System for 72 hour boiler operating without human presence according to
EN 12953 Directive
N.2 Automatically controlled minimum level probes with periodical test, complete with switch
Automatically controlled high level probes with periodical test, complete with switch
Upgraded photocell, with automatically controlled periodical test
Automatic TDS control system
Automatic blowdown
TDS CONTROL
SYSTEM
Automatic TDS control system (already included in “SAFESPARK” system 72 hour)
AUTOMATIC
BLOW-DOWN SYSTEM
Automatic blowdown system (already included in “SAFESPARK” system 72 hour)
LADDER AND
PLATFORM
Ladder and platform
THERMO - PHYSI-
CAL DEAERATOR
(ATMOSPHERIC OR
LOW-PRESSUR-
IZED)
Cylindrical body in carbon steel
Set of flanged connections
Support frame in carbon steel
Water on-off automatic valve
Feed water distribution system
Level indicator
Drain connection
Drain valve
Degassing tower (for low-pressurized deaerator)
WATER SOFTENER Water softening station DUPLEX type (other types on request)
CHEMICAL DOSING
STATION
Chemical dosing station (pH conditioner, oxygen scavenger)
BLOWDOWN
VESSEL
Blowdown vessel
STEAM
SUPERHEATER
Shell and tube configuration that heats the saturated steam coming from the cylindrical drum, exchan-
ging heat with the fumes, complete with safety valve and thermostat.
STEAM
HEADER
Steam header collecting system
CHIMNEY
Chimney complete with duct to connect boiler’s flue gas outlet, basaplate structure, cylindrical structure
shell and anchor points to fix wool panels for insulation
* complete list of all available components on request
46
8. APPENDIX 1. FUEL CONSUMPTION CALCULATION
We assume that we have to calculate natural gas fuel consumption for the production of 5500 kg/h of saturated steam,
working pressure is 13 bar, the fire tube steam boiler is a STEAM-MATIC SG 600 with economizer. Feed water temperature
is 90 °C.
As nominal steam production of the fire tube steam boiler STEAM-MATIC SG 600 is 6000 kg/h, while actual steam produc-
tion is 5500 kg/h, we calculate the load with the following equation (feed water T = 90 °C)-
According the graphic regarding the coefficient of performance (COP) of the steam boiler STEAM-MATIC SG
ECO, equipped with economizer crossed with load (see Figure 14), we define that COP is 94,7%.
In accordance with heat balance equation Q = M steam * (hg-he)/3600, where:
Q – heat needed to achieve saturated steam production with the above indicated characteristics (watt);
M steam - steam production (t/h);
hg – enthalpy of saturated steam at the above indicated steam pressure and water temperature (kcal/kg);
he – enthalpy of feeding water at the above indicated water temperature (kcal/kg);
According to the table of thermodynamic characteristics of water and saturated steam (Appendix 2), we define value hg
under 13 bar pressure gauge and he with 90 °C.
Actual useful thermal load is defined by the relation:
Q actual useful = 5 500 * (666,8 – 90,0) = 3 172 400 kcal/h.
Total thermal power in the burner is defined by the equation:
Q burner = Q actual useful / (COP,%/100),
Q burner = 3 172 400/(94,7/100) = 3 349 947 kcal/h.
Fuel heat capacity of natural gas is 8500 kcal/Nm3.
We define fuel consumption per hour of natural gas under normal conditions from the relation:
3 349 947/8 500 = 394 Nm3/h.
Load, % = * 100% Load, % = * 100% = 92%
6000
5500
91
92
93
94
95
96
25 50 75 100
Efficiency%
% Load
Efficiency at 10 bar Efficiency at 13 bar Efficiency at 16 bar
47
9. APPENDIX 2. THERMODYNAMIC CHARACTERISTICS OF SATURATED STEAM
Pm Pa T V he r hg
bar kg/cm2
bar kg/cm2
K °C m3
/kg kJ/kg kcal/kg kJ/kg kcal/kg kJ/kg kcal/kg
0,050 0,051 306,05 32,9 28,191 137,7 32,9 2425 679,2 2562,7 612,1
0,100 0,102 318,95 45,8 14,674 191,8 45,8 2394,4 571,9 2586,2 617,7
0,150 0,153 327,15 54,0 10,023 225,9 54,0 2374,8 567,2 2600,7 621,2
0,200 0,204 333,15 60,0 7,65 251,5 60,1 2359,7 563,6 2611,2 623,7
0,250 0,255 338,15 65,0 6,204 272,0 65,0 2347,5 560,7 2619,5 625,7
0,300 0,306 342,25 69,1 5,229 289,3 69,1 2337,5 558,3 2626,8 627,4
0,350 0,357 345,85 72,7 4,526 304,3 72,7 2328,7 556,2 2633 628,9
0,400 0,408 349,05 75,9 3,994 317,6 75,9 2320,7 554,3 2638,3 630,2
0,450 0,459 351,85 78,7 3,577 329,6 78,8 2313,6 552,6 2643,2 631,4
0,500 0,510 354,45 81,3 3,240 340,5 81,4 2306,9 551,0 2647,4 632,4
0,6 0,612 359,05 85,9 2,732 359,9 86,0 2295,2 548,2 2655,1 634,2
0,7 0,714 363,05 89,9 2,365 376,7 90,0 2284,3 545,6 2661,0 635,6
0,8 0,816 366,65 93,5 2,087 391,7 93,6 2275,5 543,5 2667,2 637,1
0,9 0,918 369,85 96,7 1,869 405,2 96,8 2267,2 541,5 2672,4 638,3
1,0 1,020 372,75 99,6 1,694 417,5 99,8 2259,2 539,6 2676,7 639,4
0 0 1,013 1,033 373,15 100,0 1,673 419,1 100,1 2258,4 539,4 2677,5 639,5
0,05 0,051 1,063 1,084 374,55 101,4 1,601 425,0 101,5 2254,2 538,4 2679,1 639,9
0,10 0,102 1,113 1,135 375,75 102,6 1,533 430,4 102,8 2251,2 537,7 2681,6 640,5
0,15 0,153 1,163 1,186 378,25 105,1 1,471 435,8 104,1 2247,9 536,9 2683,7 641,0
0,20 0,204 1,213 1,237 379,35 106,2 1,414 440,9 105,3 2245,0 536,2 2685,8 641,5
0,30 0,306 1,313 1,339 380,55 107,4 1,312 450,5 107,6 2238,7 534,7 2689,2 642,3
0,40 0,408 1,413 1,441 382,65 109,5 1,225 459,7 109,8 2232,8 533,3 2692,5 643,1
0,50 0,510 1,513 1,543 384,75 111,6 1,149 468,5 111,9 2227,0 531,9 2695,5 643,8
0,60 0,612 1,613 1,645 386,65 113,5 1,038 476,5 113,8 2221,5 530,6 2698,0 644,4
0,70 0,714 1,713 1,747 388,55 115,4 1,024 484,4 115,7 2216,9 529,5 2701,3 645,2
0,80 0,816 1,813 1,849 390,25 117,1 0,971 491,9 117,5 2211,9 528,3 2703,8 645,8
0,90 0,918 1,913 1,951 391,95 118,8 0,923 499,1 119,2 2206,9 527,1 2705,9 646,3
1,00 1,020 2,013 2,053 393,55 120,4 0,881 505,8 120,8 2202,3 526,0 2708,0 646,8
Pm - gauge pressure Pa - absolute pressure T – temperature V - specific volume
he - specific enthalpy of water r - specific enthalpy of evaporation
of steam
hg - specific enthalpy of saturated steam
Denomination
48
Pm Pa T V he r hg
bar kg/cm2
bar kg/cm2
K °C m3
/kg kJ/kg kcal/kg kJ/kg kcal/kg kJ/kg kcal/kg
1,00 1,020 2,013 2,053 393,55 120,4 0,881 505,8 120,8 2202,3 526,0 2708,0 646,8
1,10 1,122 2,113 2,155 395,05 121,9 0,841 512,5 122,4 2198,5 525,1 2711,0 647,5
1,20 1,224 2,213 2,257 396,55 123,4 0,806 519,2 124,0 2194,3 524,1 2713,5 648,1
1,30 1,326 2,313 2,359 398,05 124,9 0,773 525,0 125,4 2190,1 523,1 2715,1 648,5
1,40 1,428 2,413 2,461 399,45 126,3 0,743 530,9 126,8 2186,3 522,2 2717,2 649,0
1,50 1,530 2,513 2,563 400,75 127,6 0,714 536,3 128,1 2181,7 521,1 2718,1 649,2
1,60 1,632 2,613 2,664 402,05 128,9 0,689 542,2 129,5 2178,8 520,4 2721 649,9
1,70 1,733 2,713 2,766 403,25 130,1 0,665 547,2 130,7 2175 519,5 2722,3 650,2
1,80 1,835 2,813 2,868 404,55 131,4 0,643 552,7 132,0 2171,3 518,6 2723,9 650,6
1,90 1,937 2,913 2,970 405,65 132,5 0,622 557,7 133,2 2167,9 517,8 2725,6 651,0
2,00 2,039 3,013 3,072 406,85 133,7 0,603 562,7 134,4 2164,6 517 2727,3 851,4
2,20 2,243 3,213 3,278 409,05 135,9 0,568 571,9 136,6 2158,3 515,5 2730,2 652,1
2,40 2,447 3,413 3,480 411,15 138,0 0,536 581,1 138,8 2152 514,0 2733,1 652,8
2,60 2,651 3,613 3,684 413,15 140,0 0,509 589,5 140,8 2146,2 512,6 2735,7 653,4
2,80 2,855 3,813 3,888 415,05 141,9 0,483 597,9 142,8 2140,3 511,2 2738,2 654,0
3,00 3,059 4,013 4,092 416,85 143,7 0,461 605,8 144,7 2134,8 509,9 2740,7 654,6
3,20 3,263 4,213 4,296 418,55 145,4 0,44 612,9 146,4 2129,4 508,6 2742,4 655,0
3,40 3,467 4,413 4,500 420,35 147,2 0,422 620,5 148,2 2124,4 507,4 2744,9 655,6
3,60 3,671 4,613 4,704 421,95 148,8 0,405 627,6 149,9 2118,9 506,1 2746,5 656,0
3,80 3,875 4,813 4,908 423,55 150,4 0,389 634,3 151,5 2114,3 505,0 2748,6 656,5
4,00 4,079 5,013 5,112 425,15 152,0 0,374 641,0 153,1 2109,3 503,8 2750,3 656,9
4,20 4,283 5,213 5,316 426,55 153,4 0,361 647,3 154,6 2104,7 502,7 2752,0 657,3
4,40 4,487 5 413 5,520 427,95 154,8 0,348 653,6 156,1 2100,1 501,6 2753,7 657,7
4,60 4,691 5,613 5,724 429,35 156,2 0,336 659,8 157,6 2095,9 500,6 2755,8 658,2
5,00 5,099 6,013 6,131 432,05 158,9 0,315 671,1 160,3 2087,1 498,5 2758,3 658,8
5,50 5,608 6,513 6,641 435,25 162,1 0,292 685,0 163,6 2077,1 496,1 2762,0 659,7
6,00 6,118 7,013 7,151 438,15 165,0 0,272 697,9 166,7 2067,4 493,8 2765,4 660,5
6,50 6,628 7,513 7,661 440,95 167,8 0,255 710,1 169,6 2058,2 491,6 2768,3 661,2
7,00 7,138 8,013 8,171 443,65 170,5 0,240 721,8 172,4 2049,0 489,4 2770,8 661,8
7,50 7,648 8,513 8,681 446,15 173,0 0,227 733,1 175,1 2040,6 487,4 2773,8 662,5
8,00 8,158 9,013 9,191 448,55 175,4 0,215 743,6 177,6 2032,3 485,4 2775,8 663,0
9. APPENDIX 2. THERMODYNAMIC CHARACTERISTICS OF SATURATED STEAM
49
Pm Pa T V he r hg
bar kg/cm2
bar kg/cm2
K °C m3
/kg kJ/kg kcal/kg kJ/kg kcal/kg kJ/kg kcal/kg
8,50 8,667 9,513 9,700 450,85 177,7 0,204 753,6 180,0 2024,3 483,5 2777,9 663,5
9,00 9,177 10,013 10,210 453,15 180,0 0,194 763,3 182,3 2016,4 481,6 2779,6 663,9
9,50 9,687 10,513 10,720 455,25 182,1 0,185 772,9 184,6 2008,8 479,8 2781,7 664,4
10,00 10,197 11,013 11,230 457,25 184,1 0,177 782,1 186,8 2001,3 478,0 2783,4 664,8
11,00 11,217 12,013 12,250 481,15 188,0 0,163 799,3 190,9 1987,1 474,6 2786,3 665,5
12,00 12,236 13,013 13,269 464,85 191,7 0,151 815,6 194,8 1973,7 471,4 2789,2 666,2
13,00 13,256 14.013 14,289 468,25 195,1 0,141 831,1 198,5 1960,7 468,3 2791,8 666,8
14,00 14,276 15,013 15,309 471,45 198,3 0,132 845,7 202,0 1948,1 465,3 2793,9 667,3
15,00 15,296 16,013 16,328 474,55 201,4 0,124 859,6 205,3 1936,4 462,5 2795,9 667,8
16,00 16,315 17,013 17,348 477,55 204,4 0,117 872,9 208,5 1924,7 459,7 2797,6 668,2
17.00 17,335 18,013 18,368 480,35 207,2 0,110 885,5 211,5 1913,4 457,0 2798,9 668,5
18,00 18,355 19,013 19,388 483,05 209,9 0,105 897,6 214,4 1902,5 454,4 2800,1 668,8
19,00 19,374 20,013 20,407 485,65 212,5 0,100 909,4 217,2 1891,6 451,8 2801,0 669,0
20,00 20,394 21,013 21,427 488,15 215,0 0,095 921,1 220,0 1881,5 449,4 2802,6 669,4
21,00 21,414 22,013 22,447 490,45 217,3 0,090 932,0 222,6 1871,5 447,0 2803,5 669,6
22,00 22,433 23,013 23,466 492,75 219,6 0,087 942,4 225,1 1861,5 444,6 2803,9 669,7
23,00 23,453 24,013 24,486 494,95 221,8 0,083 952,9 227,6 1851,4 442,2 2804,3 669,8
24,00 24,473 25,013 25,506 497,15 224,0 0,080 963,0 230,0 1842,2 440,0 2805,2 670,0
25,00 25,493 26,013 26,525 499,25 226,1 0,077 972,6 232,3 1832,6 437,7 2805,2 670,0
26,00 26,512 27,013 27,545 501,25 228,1 0,0741 981,3 234,3 1821,6 435,0 2802,9 669,3
27,00 27,532 28,013 28,565 503,25 230,1 0,0714 990,5 236,5 1812,5 432,8 2803,0 669,4
28,00 28,552 29,013 29,585 505,15 232,0 0,0690 999,6 238,7 1803,6 430,7 2803,2 669,4
29,00 29,571 30,013 30,604 507,05 233,9 0,0667 1008,4 240,8 1794,9 428,6 2803,3 669,4
30,00 30,591 31,013 31,624 508,85 235,7 0,0645 1017,1 242,9 1786,2 426,5 2803,3 669,4
Pm - gauge pressure Pa - absolute pressure T – temperature V - specific volume
he - specific enthalpy of water r - specific enthalpy of evaporation
of steam
hg - specific enthalpy of saturated steam
Denomination
50
10. APPENDIX 3. STEAM-MATIC SG SPECIAL EXECUTIONS
This section is dedicated to special executions of STEAM-MATIC SG firetube steam boilers, showing
few examples of the great variety of solutions that BONO can provide to the customer. These are
clear examples of the attention paid to the customers’ needs and the high level of quality standards
and customization of the design and production of industrial steam boilers by BONO ENERGIA.
Figure 24
3D model of a special execution of a supplied STEAM-MATIC SG fire tube
steam boiler. The particularity of the equipment is its capacity to guaran-
tee more than 99% efficiency rate; this is possible due to the condensation
technology introduced. The result of this solution is the optimization of the
combustion fumes’ temperature (avoiding acid condensation at the chimney)
and the production of steam and hot water at a proper temperature accor-
ding to the brewing processes.
51
Figure 25
Picture of the supplied STEAM-MATIC SG fire tube steam boiler, with an effective steam
capacity of 20 ton/h at 15 bar, with efficiency rate above 99%. Field of application is a
brewery, the boiler can be fuelled with natural gas, heavy fuel oil and a combination of
natural gas and biogas, which is produced during the processes.
52
10. APPENDIX 3. STEAM-MATIC SG SPECIAL EXECUTIONS
Figure 26
3D drawings of STEAM-MATIC SG steam boilers, 20 t/h, 15 bar fuelled with
natural gas and heavy fuel oil. Each one of the three boilers is complete with
air preheaters, to achieve thermal efficiency up to 93%, and heat exchanger,
to produce superheated water from steam. The supply includes deaerator
and water treatment plant. This customized thermal plant’s field of applica-
tion is district heating.
53
54
STEAM BOILERS
» UNI-MATIC UM
FLASH COIL STEAM GENERATORS
Applications: food & beverage, textile industry,
plastics and rubber industry, woodworking,
laundries
Steam production: from 0.3 to 3 t/h
Pressure: up to 12 bar
» STEAM-MATIC SM and SG
FIRE TUBE STEAM BOILERS
Applications: pulp and paper industry, food &
beverage, district heating, plastics and rubber
industry, chemicals and petrochemical industry,
textile
Steam production: from 1 to 25 t/h
Pressure: from 12 to 30 bar
» CLAJTUB CTD
WATER TUBE STEAM BOILERS
Applications: chemical processes, refinery,
petrochemical industry, power generation
utilities, sugar refineries
Steam production: up to 180 t/h
Pressure: up to 80 bar
Temperature: up to 480 °C
» HRSG
HEAT RECOVERY STEAM GENERATORS
Applications: paper mill, chemical and
pharmaceutical, district heating, cogeneration,
textile
Steam production: up to 40 MW
From gas turbine: from 3 to 15 MW (el.),
from engine: from 3 to 20 MW (el.)
STEAM-MATIC SG
CLAJTUB CTD
UNI-MATIC UM
11. APPENDIX 4. BONO ENERGIA PRODUCT RANGE
55
THERMAL FLUID HEATERS
» OIL-MATIC OMV
THERMAL FLUID HEATERS, MULTI-COIL
TECHNOLOGY
Applications: typography, cosmetics
industry, wood & paper, chemical industry,
petrochemical
Thermal capacity: 0.2 to 6 MW
Fluid temperature: up to 350 °C
» OIL-MATIC OMP
THERMAL FLUID HEATERS, MULTITUBULAR
Applications: pharmaceutical, petrochemical
Thermal capacity: from 1.7 to 17 MW
Temperature: up to 350 °C
» OIL-MATIC HTH
HIGH TEMPERATURE THERMAL FLUID
HEATERS
Applications: district heating, oil & gas, others
Thermal capacity: from 2 to 35 MW
Temperature: up to 400 °C
SUPERHEATED WATER BOILERS
» CTH
MULTITUBULAR SUPER HEATED WATER
GENERATORS
Applications: district heating and others
Thermal capacity: up to 40 MW
package: up to 80 MW - field erected
Temperature: over 100 °C, up to 260 °C
» SM-ASA, SG-ASA
FIRE TUBE SUPERHEATED WATER BOILERS
Applications: district heating and others
Thermal capacity: from 0.7 to 17 MW
Temperature: over 100 °C
OIL-MATIC OMV
CTH
OIL-MATIC OMP
Bono Energia S.p.A
Via Resistenza 12 - 20068 Peschiera Borromeo (Mi) - Italy
Phone +39 0255302848 - Fax +39 025471955
www.bono.it
Ed. N°1
DISCLAIMER: All the data presented in this technical book are indicative and subject of changing due to
product customization and innovation processes.
They must be considered by the user only at the first stage of product selection; CANNON BONO declines
any responsibility for wrong usage of mentioned data and invites the user to contact our commercial
department for further details.

More Related Content

What's hot

Energy conservation boiler
Energy conservation boilerEnergy conservation boiler
Energy conservation boilerMANJUNATH N
 
Burners & fire boxes
Burners & fire boxesBurners & fire boxes
Burners & fire boxesSabbir Ahasan
 
furnace design
 furnace design  furnace design
furnace design Atal Khan
 
Thermal Power plant familarisation & its Auxillaries
Thermal Power plant familarisation & its AuxillariesThermal Power plant familarisation & its Auxillaries
Thermal Power plant familarisation & its AuxillariesVaibhav Paydelwar
 
Atd boilers unit 4 ppt
Atd boilers unit 4 pptAtd boilers unit 4 ppt
Atd boilers unit 4 pptMadhu Mahesh
 
Good heater specifications pay off
Good heater specifications pay off Good heater specifications pay off
Good heater specifications pay off Ashutosh Garg
 
Waste 2 Energy
Waste 2 EnergyWaste 2 Energy
Waste 2 EnergyRaul Amaro
 
Fired Heaters-Key to Efficient Operation of Refineries and Petrochemicals
Fired Heaters-Key to Efficient Operation of Refineries and PetrochemicalsFired Heaters-Key to Efficient Operation of Refineries and Petrochemicals
Fired Heaters-Key to Efficient Operation of Refineries and PetrochemicalsAshutosh Garg
 
Effect of Coal Quality and Performance of Coal pulverisers / Mills
Effect of Coal Quality and Performance of Coal pulverisers / MillsEffect of Coal Quality and Performance of Coal pulverisers / Mills
Effect of Coal Quality and Performance of Coal pulverisers / MillsManohar Tatwawadi
 
Power Plant Major Losses
Power Plant Major LossesPower Plant Major Losses
Power Plant Major Lossesguest81e1c7
 
Fired Heater and Combustion Optimization From Yokogawa
Fired Heater and Combustion Optimization From YokogawaFired Heater and Combustion Optimization From Yokogawa
Fired Heater and Combustion Optimization From YokogawaMiller Energy, Inc.
 
AIChE Smart Stack Damper Design Provides Better Control of Fired Heaters
AIChE Smart Stack Damper Design Provides Better Control of Fired HeatersAIChE Smart Stack Damper Design Provides Better Control of Fired Heaters
AIChE Smart Stack Damper Design Provides Better Control of Fired HeatersAshutosh Garg
 
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...Belilove Company-Engineers
 

What's hot (20)

Combustion control
Combustion controlCombustion control
Combustion control
 
Energy conservation boiler
Energy conservation boilerEnergy conservation boiler
Energy conservation boiler
 
Burners & fire boxes
Burners & fire boxesBurners & fire boxes
Burners & fire boxes
 
Online Efficiency Monitoring and Diagnostics in Coal Fired Boiler
Online Efficiency Monitoring and Diagnostics in Coal Fired BoilerOnline Efficiency Monitoring and Diagnostics in Coal Fired Boiler
Online Efficiency Monitoring and Diagnostics in Coal Fired Boiler
 
Developments in Industrial Boilers, WHR and Power Boilers
Developments in Industrial Boilers, WHR and Power BoilersDevelopments in Industrial Boilers, WHR and Power Boilers
Developments in Industrial Boilers, WHR and Power Boilers
 
furnace design
 furnace design  furnace design
furnace design
 
Thermal Power plant familarisation & its Auxillaries
Thermal Power plant familarisation & its AuxillariesThermal Power plant familarisation & its Auxillaries
Thermal Power plant familarisation & its Auxillaries
 
Atd boilers unit 4 ppt
Atd boilers unit 4 pptAtd boilers unit 4 ppt
Atd boilers unit 4 ppt
 
Good heater specifications pay off
Good heater specifications pay off Good heater specifications pay off
Good heater specifications pay off
 
Waste 2 Energy
Waste 2 EnergyWaste 2 Energy
Waste 2 Energy
 
Fired Heaters-Key to Efficient Operation of Refineries and Petrochemicals
Fired Heaters-Key to Efficient Operation of Refineries and PetrochemicalsFired Heaters-Key to Efficient Operation of Refineries and Petrochemicals
Fired Heaters-Key to Efficient Operation of Refineries and Petrochemicals
 
Boiler Superheater Design Modification
Boiler Superheater Design ModificationBoiler Superheater Design Modification
Boiler Superheater Design Modification
 
Effect of Coal Quality and Performance of Coal pulverisers / Mills
Effect of Coal Quality and Performance of Coal pulverisers / MillsEffect of Coal Quality and Performance of Coal pulverisers / Mills
Effect of Coal Quality and Performance of Coal pulverisers / Mills
 
Power Plant Major Losses
Power Plant Major LossesPower Plant Major Losses
Power Plant Major Losses
 
Fired Heater and Combustion Optimization From Yokogawa
Fired Heater and Combustion Optimization From YokogawaFired Heater and Combustion Optimization From Yokogawa
Fired Heater and Combustion Optimization From Yokogawa
 
Power plant engineering
Power plant engineeringPower plant engineering
Power plant engineering
 
Reheating Furnace -- Walking Beam Reheating Furnace
Reheating Furnace -- Walking Beam Reheating FurnaceReheating Furnace -- Walking Beam Reheating Furnace
Reheating Furnace -- Walking Beam Reheating Furnace
 
AIChE Smart Stack Damper Design Provides Better Control of Fired Heaters
AIChE Smart Stack Damper Design Provides Better Control of Fired HeatersAIChE Smart Stack Damper Design Provides Better Control of Fired Heaters
AIChE Smart Stack Damper Design Provides Better Control of Fired Heaters
 
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...
 
O&amp;m of boiler
O&amp;m of boilerO&amp;m of boiler
O&amp;m of boiler
 

Similar to 2013 en sg_light

Oil fired boiler | diesel fired boiler | furnace oil fired boiler | high s...
Oil fired boiler  | diesel fired boiler  | furnace oil fired boiler  | high s...Oil fired boiler  | diesel fired boiler  | furnace oil fired boiler  | high s...
Oil fired boiler | diesel fired boiler | furnace oil fired boiler | high s...Ravindra Dhumal
 
Industrial oil or gas fired boiler
Industrial  oil or  gas fired boilerIndustrial  oil or  gas fired boiler
Industrial oil or gas fired boilerRavindra Dhumal
 
Water tube boiler features
Water tube boiler featuresWater tube boiler features
Water tube boiler featureszgboilers
 
Coke oven life prolongation a multidisciplinary approach
Coke oven life prolongation   a multidisciplinary approachCoke oven life prolongation   a multidisciplinary approach
Coke oven life prolongation a multidisciplinary approachJorge Madias
 
Brochure_Range_Of_Products_And_Services
Brochure_Range_Of_Products_And_ServicesBrochure_Range_Of_Products_And_Services
Brochure_Range_Of_Products_And_ServicesAnton Besaris
 
Compact Muffle Furnace (1700 °C) by ACMAS Technologies Pvt Ltd.
Compact Muffle Furnace (1700 °C) by ACMAS Technologies Pvt Ltd.Compact Muffle Furnace (1700 °C) by ACMAS Technologies Pvt Ltd.
Compact Muffle Furnace (1700 °C) by ACMAS Technologies Pvt Ltd.Acmas Technologies Pvt. Ltd.
 
Report on Boilers at NTPC Ramagunadam
Report on  Boilers at NTPC RamagunadamReport on  Boilers at NTPC Ramagunadam
Report on Boilers at NTPC RamagunadamAbhinay Angari
 
Soot Blowing Optimization- Field Experience
Soot Blowing Optimization- Field ExperienceSoot Blowing Optimization- Field Experience
Soot Blowing Optimization- Field ExperiencePooja Agarwal
 
Attsu steam boilers faqs october 2020
Attsu steam boilers faqs october 2020Attsu steam boilers faqs october 2020
Attsu steam boilers faqs october 2020ATTSU
 
Sb ls scroll-uc-ii_ver.1.0_en
Sb ls scroll-uc-ii_ver.1.0_enSb ls scroll-uc-ii_ver.1.0_en
Sb ls scroll-uc-ii_ver.1.0_enYury Naumov
 
Adoption of supercritical technology (1)
Adoption of supercritical technology (1)Adoption of supercritical technology (1)
Adoption of supercritical technology (1)HARSHIT GUPTA
 
Improving Efficiency for Boiler and Steam System
Improving Efficiency for Boiler and Steam SystemImproving Efficiency for Boiler and Steam System
Improving Efficiency for Boiler and Steam SystemKamlesh Hariyani
 
Duncan cairnie ccm energy solutions hvacr seminar- april 2016
Duncan cairnie ccm energy solutions   hvacr seminar- april 2016Duncan cairnie ccm energy solutions   hvacr seminar- april 2016
Duncan cairnie ccm energy solutions hvacr seminar- april 2016ARAaus
 
Seven zones split tube furnace with separated temperature controller
Seven zones split tube furnace with separated temperature controllerSeven zones split tube furnace with separated temperature controller
Seven zones split tube furnace with separated temperature controllerAcmas Technologies Pvt. Ltd.
 
Aph operation and emergency handling
Aph operation and emergency handlingAph operation and emergency handling
Aph operation and emergency handlingParag Agrawal
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow ovenMark Tung
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow ovenLucy Xiao
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow ovenCarrie Zhang
 

Similar to 2013 en sg_light (20)

Oil fired boiler | diesel fired boiler | furnace oil fired boiler | high s...
Oil fired boiler  | diesel fired boiler  | furnace oil fired boiler  | high s...Oil fired boiler  | diesel fired boiler  | furnace oil fired boiler  | high s...
Oil fired boiler | diesel fired boiler | furnace oil fired boiler | high s...
 
Industrial oil or gas fired boiler
Industrial  oil or  gas fired boilerIndustrial  oil or  gas fired boiler
Industrial oil or gas fired boiler
 
Kalsi industries
Kalsi industriesKalsi industries
Kalsi industries
 
Water tube boiler features
Water tube boiler featuresWater tube boiler features
Water tube boiler features
 
Coke oven life prolongation a multidisciplinary approach
Coke oven life prolongation   a multidisciplinary approachCoke oven life prolongation   a multidisciplinary approach
Coke oven life prolongation a multidisciplinary approach
 
Brochure_Range_Of_Products_And_Services
Brochure_Range_Of_Products_And_ServicesBrochure_Range_Of_Products_And_Services
Brochure_Range_Of_Products_And_Services
 
Compact Muffle Furnace (1700 °C) by ACMAS Technologies Pvt Ltd.
Compact Muffle Furnace (1700 °C) by ACMAS Technologies Pvt Ltd.Compact Muffle Furnace (1700 °C) by ACMAS Technologies Pvt Ltd.
Compact Muffle Furnace (1700 °C) by ACMAS Technologies Pvt Ltd.
 
Report on Boilers at NTPC Ramagunadam
Report on  Boilers at NTPC RamagunadamReport on  Boilers at NTPC Ramagunadam
Report on Boilers at NTPC Ramagunadam
 
Fracaro ponuda
Fracaro ponudaFracaro ponuda
Fracaro ponuda
 
Soot Blowing Optimization- Field Experience
Soot Blowing Optimization- Field ExperienceSoot Blowing Optimization- Field Experience
Soot Blowing Optimization- Field Experience
 
Attsu steam boilers faqs october 2020
Attsu steam boilers faqs october 2020Attsu steam boilers faqs october 2020
Attsu steam boilers faqs october 2020
 
Sb ls scroll-uc-ii_ver.1.0_en
Sb ls scroll-uc-ii_ver.1.0_enSb ls scroll-uc-ii_ver.1.0_en
Sb ls scroll-uc-ii_ver.1.0_en
 
Adoption of supercritical technology (1)
Adoption of supercritical technology (1)Adoption of supercritical technology (1)
Adoption of supercritical technology (1)
 
Improving Efficiency for Boiler and Steam System
Improving Efficiency for Boiler and Steam SystemImproving Efficiency for Boiler and Steam System
Improving Efficiency for Boiler and Steam System
 
Duncan cairnie ccm energy solutions hvacr seminar- april 2016
Duncan cairnie ccm energy solutions   hvacr seminar- april 2016Duncan cairnie ccm energy solutions   hvacr seminar- april 2016
Duncan cairnie ccm energy solutions hvacr seminar- april 2016
 
Seven zones split tube furnace with separated temperature controller
Seven zones split tube furnace with separated temperature controllerSeven zones split tube furnace with separated temperature controller
Seven zones split tube furnace with separated temperature controller
 
Aph operation and emergency handling
Aph operation and emergency handlingAph operation and emergency handling
Aph operation and emergency handling
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow oven
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow oven
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow oven
 

More from milos639

Pravilnik o listi opasnih materija
Pravilnik o listi opasnih   materijaPravilnik o listi opasnih   materija
Pravilnik o listi opasnih materijamilos639
 
Opterecenje bakarnih izolovanih provodnika
Opterecenje bakarnih izolovanih provodnikaOpterecenje bakarnih izolovanih provodnika
Opterecenje bakarnih izolovanih provodnikamilos639
 
Pravilnik o nacinu i postupku procene rizika na radnom mestu i u radnoj okolini
Pravilnik o nacinu i postupku procene rizika na radnom mestu i u radnoj okoliniPravilnik o nacinu i postupku procene rizika na radnom mestu i u radnoj okolini
Pravilnik o nacinu i postupku procene rizika na radnom mestu i u radnoj okolinimilos639
 
Uputstvo za s9
Uputstvo za s9Uputstvo za s9
Uputstvo za s9milos639
 
Co2 aparat upotreba
Co2 aparat upotrebaCo2 aparat upotreba
Co2 aparat upotrebamilos639
 

More from milos639 (6)

Pravilnik o listi opasnih materija
Pravilnik o listi opasnih   materijaPravilnik o listi opasnih   materija
Pravilnik o listi opasnih materija
 
Opterecenje bakarnih izolovanih provodnika
Opterecenje bakarnih izolovanih provodnikaOpterecenje bakarnih izolovanih provodnika
Opterecenje bakarnih izolovanih provodnika
 
Pravilnik o nacinu i postupku procene rizika na radnom mestu i u radnoj okolini
Pravilnik o nacinu i postupku procene rizika na radnom mestu i u radnoj okoliniPravilnik o nacinu i postupku procene rizika na radnom mestu i u radnoj okolini
Pravilnik o nacinu i postupku procene rizika na radnom mestu i u radnoj okolini
 
Kiney
KineyKiney
Kiney
 
Uputstvo za s9
Uputstvo za s9Uputstvo za s9
Uputstvo za s9
 
Co2 aparat upotreba
Co2 aparat upotrebaCo2 aparat upotreba
Co2 aparat upotreba
 

Recently uploaded

Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AIabhishek36461
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile servicerehmti665
 
Introduction to Microprocesso programming and interfacing.pptx
Introduction to Microprocesso programming and interfacing.pptxIntroduction to Microprocesso programming and interfacing.pptx
Introduction to Microprocesso programming and interfacing.pptxvipinkmenon1
 
Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.eptoze12
 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxDeepakSakkari2
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝soniya singh
 
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfAsst.prof M.Gokilavani
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerAnamika Sarkar
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Dr.Costas Sachpazis
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVRajaP95
 
Internship report on mechanical engineering
Internship report on mechanical engineeringInternship report on mechanical engineering
Internship report on mechanical engineeringmalavadedarshan25
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024hassan khalil
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSKurinjimalarL3
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130Suhani Kapoor
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxJoão Esperancinha
 
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...ZTE
 
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ
 
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfCCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfAsst.prof M.Gokilavani
 

Recently uploaded (20)

Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AI
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile service
 
Introduction to Microprocesso programming and interfacing.pptx
Introduction to Microprocesso programming and interfacing.pptxIntroduction to Microprocesso programming and interfacing.pptx
Introduction to Microprocesso programming and interfacing.pptx
 
Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.
 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptx
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
 
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
 
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
 
Internship report on mechanical engineering
Internship report on mechanical engineeringInternship report on mechanical engineering
Internship report on mechanical engineering
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
 
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
 
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
 
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfCCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
 

2013 en sg_light

  • 2. 2
  • 3. 3 1. General Information 2. Competitive Advantages 3. Technical Specifications 4. P&ID 5. Boiler Layout 6. Installation 7. Scope of Supply 8. Appendix 1. Fuel consumption calculation 9. Appendix 2. Thermodynamic characteristics of saturated steam 10. Appendix 3. STEAM-MATIC SG special executions 11. Appendix 4. BONO ENERGIA product range STEAM BOILERS STEAM-MATIC - SG
  • 4. 4 STEAM-MATIC SG fire tube steam boilers produce saturated or superheated steam, with design pressure range from 12 bar up to 30 bar. Range of steam production is between 6000 and 25000 Kg/h. An efficient design, high-quality construction and an innovative control system guarantee high level performance and low energy costs. Models available: • SG 600: up to 6.000 Kg/h • SG 800: up to 8.000 Kg/h • SG 1000: up to 10.000 Kg/h • SG 1200: up to 12.000 Kg/h • SG 1500: up to 15.000 Kg/h • SG 2000: up to 20.000 Kg/h • SG 2200: up to 22.000 Kg/h • SG 2500: up to 25.000 Kg/h Thermal efficiency reaches 95% thanks to the optimization of heat exchange and by using our economizer, an equipment which can be fully integrated into the boiler. Thermal efficiency higher than 95% may be achieved thanks to special solutions by Cannon BONO. Fields of application of STEAM-MATIC SG boilers are: pulp and paper industry, food & beverage, district heating, plastics and rubber industry, chemicals and petrochemical, woodworking, production of building material, textile industry. STEAM-MATIC SG boilers are marked and can be produced according to the most important and rigorous directives, such as: - PED Directive 97/23/CE - Machinery Directive (MD) 2006/42/CE - Gas Directive 2009/73/EC according to PED - Low Voltage Directive (LVD) 2006/95/EC - Electromagnetic Directive 89/336/EEC. 1. GENERAL INFORMATION Figure 1 Steam boilers STEAM-MATIC SG
  • 5. 5 1 Burner 6 Exhaust Gas Outlet 2 Safety Valves 7 Drain Connection 3 STEAM-MATIC Furnace 8 Fire Tubes of the 2nd Pass (*) 4 Burner Flame 9 Wet Back Water Tubes 5 Level Probes 10 Integrated Economizer (OPTIONAL) * = the fire tubes of the second pass are mainly covering the same furnace lateral area on both sides, the smoke flow in the drawing is just for representation purposes. Figure 2 Steam boiler STEAM-MATIC SG functional diagram
  • 6. 6 • Thermal efficiency up to 95% and higher Thanks to an optimized heating surface and to the optional supply of economizers (air or water preheater). • Better heat exchanging process The wide heating surfaces enable a better heat exchange; these optimal conditions are granted in each of the tubes of the boiler, avoiding thermal flow unbalance and thermal stresses in the structure elements. • Two passes are better than three A two passes boiler has a more balanced heat transfer from the tubes to the water and less thermal stresses in the metal structure; moreover the simplicity of construction of a two passes boiler enables a total accessibility to the furnace and the tubes for inspection purposes and ordinary maintenance. • Bigger water content volume A bigger water volume gives to the boiler a better steam supply flexibility and stability of the steam pressure and water level. • Bigger furnace volume This feature permits lower thermal loads in the structure and better heat exchange, which avoids structural dilatations and lower values of the NOx emissions. • Supply of “turn-key” boiler units Boiler units are supplied ready for use. The boiler is supplied with feed water pumps, burning system (gaseous, diesel or heavy fuel), electric cabinet with Cannon BONO con- trol and management system OPTISPARK. • Customer oriented solutions Cannon BONO’s technical specialists are ca- pable of meeting any customer’s request, thus having the possibility to offer a great variety of solutions studied specifically for the cus- tomer’s needs, starting from boiler construc- tion to type of fuel burned (especially thanks to our know-how in designing and realizing each component of the boiler in Cannon BONO fac- tory). 2. COMPETITIVE ADVANTAGES Figure 3 Steam boiler STEAM-MATIC SG Figure 4 Control panel for steam boiler STEAM-MATIC SG with OPTISPARK control and management system.
  • 7. 7 TWO PASSES ARE BETTER THAN THREE STEAM-MATIC serie SG combines the competitive advantages of a fully water cooled back side with a symmet- rical configuration of tubes and plates, ensuring easy inspection operations and greater performance benefits. The simple boiler design and the full accessibility to the fire tubes, without disassembling the burner or re- moving accessories (both in the frontal and back smoke chamber), make the STEAM-MATIC SG series the best solution for any steam need. STEAM-MATIC SG furnace A large furnace, combined with an optimized heat transfer, represent the smartest solution for the best pos- sible thermal exchange conditions across all the tube bundle, avoiding the thermal load umbalance between the 2nd and the 3rd pass typical of a 3 pass smoke tubes boilers. Preventing these thermal umbalance conditions means also avoiding dangerous thermal stresses in the structure of the pressure vessel itself, which are the main cause of cracks and deformations. Moreover the rear tubes plates are exposed to a uniform thermal load. An optimized heat transfer In a 3 pass boiler most of the heat transfer occurs in the 2nd pass, while in the 3rd pass the transfer becomes negligible and may expose the tubes to corrosion (dew point) phenomena. All the boilers of our STEAM-MATIC SG serie are equipped with Intensive Radiant Tubes (I.R.T) which promote: - High thermal exchange also in convection conditions - Negligible flow friction rate, with consequent modest burner fan power needed - Optimized heat flow along the entire section of the tubes - Higher speed of the flue gases even with boiler running at low rate 2. COMPETITIVE ADVANTAGES - OPTIMIZATION Figure 5 Heat transfer efficiency slope
  • 8. 8 The thermal flow on a three pass boiler is uneven and tends to concentrate in the central area of the smoke tubes; therefore the heat transfer becomes significantly lower, especially in the third pass. Easy access to the burner side tubes The STEAM MATIC SG frontal smoke chamber can be easily reached without burner disassembling, thanks to the two lateral front hinged doors. This solution allows fast and costless cleaning operations in order to preserve the optimal smokes tubes conditions. The rear smoke chamber can be fastly inspected by means of a wide manhole which enables the operator to completely enter the chamber and inspect the rear end of the smoke tubes. The position of the tubes themselves, allocated at both sides of the furnace, permits the operator to easily check their status. Heat recovery system STEAM-MATIC boilers may feature a recovery system (Economizer) integrated in the boiler structure, which can be easily and fully inspected and do not require expensive or bulky additional gas ducts, often necessary in a 3 pass design. The economizers can be easily integrated as optional in the existing structure, which is already shaped and designed to receive them with an easy inserting operation. Our SG integrated recovery system gives significant fuel savings by increasing the boiler efficiency of 4-5%, it moreover speeds up combustion in adverse conditions, such as cold furnace or rapid variation of room temperature. Installation of the air-preheater together with the economizer and other customized solutions enables STEAM-MATIC SG boiler to reach up to 99% of efficiency. Figure 6 Efficiency comparison between 2 and 3 smoke passes
  • 9. 9 Easy inspection of the second pass fire tubes from the rear smoke chamber Easy access to the rear smoke chamber from a wide manhole Easy inspection of the second pass fire tubes from the frontal smoke chamber 2. COMPETITIVE ADVANTAGES - BOILER CONSTRUCTION Figure 7 Easy access spots in a STEAM-MATIC boiler SG Easy access to the heat recovery system
  • 10. 10 2. COMPETITIVE ADVANTAGES - AUTOMATIC CONTROL AND MANAGEMENT SYSTEM FOR INDUSTRIAL BOILER PLANTS GARC VPS Figure 8 Control and management system OPTISPARK’s interface Figure 9 Automatic control and management system for in- dustrial boiler plants OPTISPARK functional scheme. BONO OPTISPARK is the automatic control and manage- ment system for industrial boilers and boiler rooms which ensures: • CONTINUOUS AND SAFETY OPERATION • OPERATIVE SAFETY • ENERGY EFFICIENCY • LOWER OWNERSHIP COSTS • INFORMATION AVAILABILITY FOR MAINTENANCE ACTIVI- TIES BONO OPTISPARK is applicable to all types of boilers, new or already operating; it is suitable for any burner and it is in- terfaceable with any supervisory control and data acquisition (SCADA) and any distribution control system (DCS). The system fits any industrial process and district heating. The human machine interface is user friendly; the touch screen operator panel is available in two sizes: 5.7’’ and 10.4’’. GARCGARC
  • 11. 11 BCU SIL3 Key technical features of OPTISPARK system: • Integrated Burner Controller BCU - (Burner Control Unit), SIL3 certified • Burner start-up sequence management, flame protection and gas Valve Proving System (VPS) in compliance with EN298 and EN1643 • Micrometric Gas/Air Ratio Control (GARC) in compliance with EN 12067/2 • Level regulation up to three elements with steam flow and feed water flow control • Management of the inverter installed on the feed water pump and on the fan engine to achieve maximum energy savings and to reduce noise level • Heat recovery management and energy-saving registration for green benefits achievement • Integrated management of the pollutant reduction systems to the chimney (very low NOx emission) • Oxygen and Carbon Monoxide combustion trim • Calculation of energy saving and green benefits. • Continuos emissions monitoring system in compliance with local legislations • Power load sharing system between more boilers in the same boiler room • Historical data recording, alerts and notifications via SMS • Totalization of water and fuel consumption, steam production, boiler and pumps operation time • Managemet of deaerators, water treatment system and auxiliary equipment • LAN port for remote control and supervision • BONO maintenance and service via Internet or GPRS modem
  • 12. 12 Table 1 Technical specifications and overall dimensions of steam boiler STEAM-MATIC SG. Data are refered to SG models without economizer or air preheater. The below listed information is generalized to the entire range of models STEAM-MATIC SG, it’s only indicative and may change in accordance with each final boiler configuration. Additional data and deviations from standard are available on request. 3. TECHNICAL SPECIFICATIONS - STEAM-MATIC SG TECHNICAL SPECIFICATIONS Features Unit SG 600 SG 800 SG 1000 SG 1200 SG 1500 SG 2000 SG 2200 SG 2500 Nominal steam production Kg/h 6000 8000 10000 12000 15000 20000 22000 25000 Design pressure* bar 12 15 18 12 15 18 12 15 18 12 15 18 12 15 18 12 15 18 12 15 12 15 Min.feed water temp. °C 90 90 90 90 90 90 90 90 Thermal efficiency** % 90 89,5 89 90 89,5 89 90 89,5 89 90 89,5 89 90 89,5 89 90 89,5 89 90 89,5 90 89,5 OVERALL DIMENSIONS AND CONNECTIONS L Lenght mm 7400 7950 8350 8900 9400 10300 11000 12000 W Width mm 3250 3250 3600 3600 3750 3750 3900 4000 H Height mm 2900 2900 3250 3300 3550 3800 3800*** 3800*** N2 Steam valve DN 125 125 100 150 125 100 150 150 125 150 150 150 200 150 150 200 200 200 250 200 250 200 PN 16 40 40 16 40 40 16 40 40 16 40 40 16 40 40 16 40 40 16 40 16 40 N4A N4B Safety valve outlet DN 40/ 65 40/ 65 40/ 65 40/ 65 40/ 65 40/ 65 50/ 80 40/ 65 40/ 65 50/ 80 50/ 80 40/ 65 65/ 100 50/ 80 50/ 80 65/ 100 65/ 100 50/ 80 65/ 100 80/ 100 65/ 100 65/ 100 PN 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 25/ 16 25/ 16 N9 Boiler drain DN 40 40 40 40 40 40 40 40 PN 16 16 16 16 16 16 16 16 N 18A 18B Feed water line**** Ø 3” 3” 4” 4” 4” 5” 5” 6” N16 Reversal chamber drain DN 32 32 32 32 32 32 32 32 PN 16 16 16 16 16 16 16 16 N15 Heavy fuel oil inlet Ø 2” 2” 2”½ 2”½ 2”½ 2”½ 2”½ 2”½ N17 Natural gas inlet Ø 3” 4” 4” 4” 5” 5” 5” 6” N19 Stack connection mm 600 600 720 720 800 850 920 920 Empty weight T 17,0 17,8 18,7 20,0 21,0 22,2 23,0 24,3 25,7 26,0 27,6 29,2 32,0 34,2 36,1 38,0 41,4 43,0 39,5 42 40,5 43 Water volume at level m3 9,3 10,0 11,0 13,0 17,7 19,0 22,0 36,0 Full water volume m3 12,3 13,3 15,0 18,0 23,5 26,0 29,3 42,0 TOTAL ELECTRIC POWER Heavy fuel oil ***** KW 31,3 32,8 34,8 38,8 38,8 42,8 48,8 52,8 52,8 56,8 60,8 64,3 71,1 74,6 78,1 82,6 86,1 101,1 89,0 92,0 101,0 Natural gas or diesel oil KW 18,5 20,0 22,0 26,0 26,0 30,0 33,0 37,0 37,0 41,0 45,0 48,5 52,0 55,5 59,0 64,0 67,0 67,0 75,0 78,0 86,0 Standard electric power data: 400 V/50 Hz/ – 3 phases Auxiliaries voltage: 220 V FUEL CONSUMPTION Heavy fuel calorific power: 9700 kcal/kg (for actual fuel consumption calculation see Appendix 1). Diesel fuel calorific power: 10200 kcal/kg (for actual fuel consumption calculation see Appendix 1). Natural gas calorific power: 8500 kcal/Nm3 (for actual fuel consumption calculation see Appendix 1). * Design pressure above 18 bar or below 12 bar on request. ** Thermal efficiency at 100% of the load, with water temperature 90 °C. See Figure 13 for more information. *** Height is calculated without air fan. **** Connection size depends on feed water pump supplier. ***** Maximum heavy fuel viscosity is 7°E under 50°C temperature. Information about heavy fuel with higher viscosity on request.
  • 13. 13 Figure 10 STEAM-MATIC SG steam boiler overall dimension. More detailed information on request
  • 14. 14 Table 2 Technical specifications and overall dimensions of steam boiler STEAM-MATIC SG ECO. Data are refered to SG models with economizer. The below listed information is generalized to the entire range of models STEAM-MATIC SG, it’s only indicative and may change in accordance with each final boiler configuration. Additional data and deviations from standard are available on request. 3. TECHNICAL SPECIFICATIONS - STEAM-MATIC SG ECO (WITH ECONOMIZER) TECHNICAL SPECIFICATIONS Features Unit SG ECO 600 SG ECO 800 SG ECO 1000 SG ECO 1200 SG ECO 1500 SG ECO 2000 SG ECO 2200 SG ECO 2500 Nominal steam production Kg/h 6000 8000 10000 12000 15000 20000 22000 25000 Design pressure* bar 12 15 18 12 15 18 12 15 18 12 15 18 12 15 18 12 15 18 12 15 12 15 Min.feed water temp. °C 90 90 90 90 90 90 90 90 Thermal efficiency (with economizer)** % 95 94,5 94 95 94,5 94 95 94,5 94 95 94,5 94 95 94,5 94 95 94,5 94 95 94,5 95 94,5 OVERALL DIMENSIONS AND CONNECTIONS L Lenght mm 7400 7950 8350 8900 9400 10300 11000 12000 W Width mm 3250 3250 3600 3600 3750 3750 3900 4000 H Height mm 2900 2900 3250 3300 3550 3800 3800*** 3800*** N2 Steam valve DN 125 125 100 150 125 100 150 150 125 150 150 150 200 150 150 200 200 200 250 200 250 200 PN 16 40 40 16 40 40 16 40 40 16 40 40 16 40 40 16 40 40 16 40 16 40 N4A N4B Safety valve outlet DN 40/ 65 40/ 65 40/ 65 40/ 65 40/ 65 40/ 65 50/ 80 40/ 65 40/ 65 50/ 80 50/ 80 40/ 65 65/ 100 50/ 80 50/ 80 65/ 100 65/ 100 50/ 80 65/ 100 80/ 100 65/ 100 65/ 100 PN 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 25/ 16 25/ 16 N9 Boiler drain DN 40 40 40 40 40 40 40 40 PN 16 16 16 16 16 16 16 16 N 18A 18B Feed water line**** Ø 3” 3” 4” 4” 4” 5” 5” 6” N16 Reversal chamber drain DN 32 32 32 32 32 32 32 32 PN 16 16 16 16 16 16 16 16 N15 Liquid fuel inlet Ø 2” 2” 2”½ 2”½ 2”½ 2”½ 2”½ 2”½ N17 Natural gas inlet Ø 3” 4” 4” 4” 5” 5” 5” 6” N19 Stack connection mm 600 600 720 720 800 850 920 920 Empty weight T 17,6 18,4 19,3 20,6 21,6 22,8 24,0 25,3 26,7 27,0 28,6 30,2 33,2 35,4 37,3 39,4 42,8 44,4 40,9 43,4 42 44,5 Water volume at level m3 9,3 10,0 11,0 13,0 17,7 19,0 22,0 36,0 Full water volume m3 12,3 13,3 15,0 18,0 23,5 26,0 29,3 42,0 TOTAL ELECTRIC POWER Heavy fuel oil ***** KW 35,3 36,8 38,8 38,8 38,8 42,8 48,8 52,8 52,8 56,8 60,8 64,3 71,1 74,6 78,1 82,6 86,1 101,1 89,0 92,0 101,0 Natural gas or diesel oil KW 23,0 24,0 26,0 26,0 26,0 30,0 33,0 37,0 37,0 41,0 45,0 48,5 52,0 55,5 59,0 64,0 67,0 67,0 75,0 78,0 86,0 Standard electric power data: 400 V/50 Hz/ – 3 phases Auxiliaries voltage: 220 V FUEL CONSUMPTION Heavy fuel calorific power: 9700 kcal/kg (for actual fuel consumption calculation see Appendix 1). Diesel fuel calorific power: 10200 kcal/kg (for actual fuel consumption calculation see Appendix 1). Natural gas calorific power: 8500 kcal/Nm3 (for actual fuel consumption calculation see Appendix 1). * Design pressure above 18 bar or below 12 bar on request. ** Thermal efficiency at 100% of the load, with water temperature 90 °C. See Figure 14 and for more information. *** Height is calculated without air fan. **** Connection size depends on feed water pump supplier. ***** Maximum heavy fuel viscosity is 7°E under 50°C temperature. Information about heavy fuel with higher viscosity on request.
  • 15. 15 Figure 11 STEAM-MATIC SG ECO steam boiler overall dimension. Boiler is equipped with economizer for heat recovery.
  • 16. 16 TECHNICAL SPECIFICATIONS Features Unit SG PA 600 SG PA 800 SG PA 1000 SG PA 1200 SG PA 1500 SG PA 2000 SG PA 2200 SG PA 2500 Nominal steam production Kg/h 6000 8000 10000 12000 15000 20000 22000 25000 Design pressure* bar 12 15 18 12 15 18 12 15 18 12 15 18 12 15 18 12 15 18 12 15 12 15 Min.feed water temp. °C 90 90 90 90 90 90 90 90 Thermal efficiency (with air preheater)** % 92,5 92 91,5 92,5 92 91,5 92,5 92 91,5 92,5 92 91,5 92,5 92 91,5 92,5 92 91,5 92,5 92 92,5 92 OVERALL DIMENSIONS AND CONNECTIONS L Lenght mm 7150 7650 7900 8400 9200 10.000 *** *** W Width mm 3000 3000 3250 3250 3600 3.600 *** *** H Height (with air prehe- ater) mm 3700 3700 4050 4050 4560 4.560 *** *** N2 Steam valve DN 125 125 100 150 125 100 150 150 125 150 150 150 200 150 150 200 200 200 250 200 250 200 PN 16 40 40 16 40 40 16 40 40 16 40 40 16 40 40 16 40 40 16 40 16 40 N4A N4B Safety valve outlet DN 40/ 65 40/ 65 40/ 65 40/ 65 40/ 65 40/ 65 50/ 80 40/ 65 40/ 65 50/ 80 50/ 80 40/ 65 65/ 100 50/ 80 50/ 80 65/ 100 65/ 100 50/ 80 65/ 100 80/ 100 65/ 100 65/ 100 PN 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 40/ 16 25/ 16 25/ 16 25/ 16 25/ 16 N9 Boiler drain DN 40 40 40 40 40 40 40 40 PN 16 16 16 16 16 16 16 16 N 18A 18B Feed water line***** Ø 3” 3” 4” 4” 4” 5” 5” 6” N16 Reversal chamber drain DN 32 32 32 32 32 32 32 32 PN 16 16 16 16 16 16 16 16 N15 Heavy fuel oil inlet Ø 2” 2” 2”½ 2”½ 2”½ 2”½ 2”½ 2”½ N17 Natural gas inlet Ø 3” 4” 4” 4” 5” 5” 5” 6” N19 Stack connection mm 600 600 720 720 800 850 920 920 Empty weight T 18,0 18,8 19,7 21,0 22,0 23,2 24,0 25,3 27,1 27,0 28,6 30,2 35,0 37,2 39,1 40,0 43,4 45,0 41,9 44,4 43 45,5 Water volume at level m3 9,3 10,0 11,0 13,0 17,7 19,0 22,0 36,0 Full water volume m3 12,3 13,3 15,0 18,0 23,5 26,0 29,3 42,0 TOTAL ELECTRIC POWER Heavy fuel oil **** KW 35,3 36,8 38,8 38,8 38,8 42,8 48,8 52,8 52,8 56,8 60,8 64,3 71,1 74,6 78,1 82,6 86,1 101,1 89,0 92,0 101,0 Natural gas or diesel oil KW 23,0 24,0 26,0 26,0 26,0 30,0 33,0 37,0 37,0 41,0 45,0 48,5 52,0 55,5 59,0 64,0 67,0 67,0 75,0 78,0 86,0 Standard electric power data: 400 V/50 Hz/ – 3 phases Auxiliaries voltage: 220 V FUEL CONSUMPTION Heavy fuel calorific power: 9700 kcal/kg (for actual fuel consumption calculation see Appendix 1). Diesel fuel calorific power: 10200 kcal/kg (for actual fuel consumption calculation see Appendix 1). Natural gas calorific power: 8500 kcal/Nm3 (for actual fuel consumption calculation see Appendix 1). * Design pressure above 18 bar or below 12 bar on request. ** Thermal efficiency at 100% of the load, with water temperature 90 °C. *** Height is calculated without air fan. **** Connection size depends on feed water pump supplier. ***** Maximum heavy fuel viscosity is 7°E under 50°C temperature. Information about heavy fuel with higher viscosity on request. Table 3 Technical specifications and overall dimensions of steam boiler STEAM-MATIC SG PA with air preheater. The below listed information is generalized to the entire range of models STEAM-MATIC SG PA, it’s only indicative and may change in accordance with each final boiler configuration. Additional data and deviations from standard are available on request. 3. TECHNICAL SPECIFICATIONS - STEAM-MATIC SG PA (WITH AIR PREHEATER)
  • 17. 17 Figure 12 STEAM-MATIC SG PA steam boiler overall dimension. Boiler is equipped with air preheater for heat recovery.
  • 18. 18 3. TECHNICAL SPECIFICATIONS - THERMAL EFFICIENCY Figure 14 The coefficient of performance (COP) of the steam boiler STEAM-MATIC equipped with economizer*. * Load, % = * 100% , with T feed water at 90° C. Figure 13 The coefficient of performance (COP) of the steam boiler STEAM-MATIC crossed with the load*.
  • 19. 19 The quality of the water constitutes one of the most important factors regarding duration, safety and reliability of the steam generator and therefore the entire thermal plant. The “water circuit” elements are essentially comprised of: • Unpurified water treatment system: treats the waters available, making them suitable for re-integration into the plant. The most common methods of treatment are: filters, softeners, reverse osmosis plants, demineralizers, etc. • Thermophysical degaser: it is made up from an accumulation tank where condensate returning from the utilities and reintegration water converge. Heating takes place inside the degaser by introducing a regulated flow rate of steam. The purpose of the treatment is to eliminate the gaseous fractions dissolved in the feed water, particularly considering oxygen. • Chemical products dosing control unit: it is made up from one or more tanks fitted with manually regulated dosing pumps, which send the chemical products into the water supply circuit. Some chemical products must be stored in a tank fitted with stirrer. • Boiler bottom outlet and surface blowdown: they allow to keep the amount of salts dissolved and the amount of slurry inside the boiler drum within the envisioned limits. The quantity of the continuous blowdown operations is tightly linked to the percentage of total solids in the boiler water: the assistance of a laboratory specialized in the analysis of water can help in defining the real quantity and frequency of blowdown operations necessary to maintain normal concentrations. Table 4 Feedwater Quality Requirements for best STEAM-MATIC SG opera- tion and preservation (a) With copper alloys in the system the pH value shall be maintained in the range from 8.7 to 9.2. (b) With softened water pH value >7.0 - see the manual of the boiler. (c) If the operating pressure is <1 bar, the max total acceptable hardness should be 0.05 mmol / l. (d) In order to observe this value at intermitted operation or operation without deareator an oxygen scavenger shall be used. (e) Organic substances are generally a mixture of several different compounds. The composition of such mixtures and behaviour of their individual components under the conditions of boiler operation are difficul to predict. Organic substances may be decomposed to form carbonic acid or other acidic decomposition products which increase the acid conductivity and cause corrosion or deposits. They also may lead to foaming and/or priming which shall be kept as low as possible. 3. TECHNICAL SPECIFICATIONS - WATER PROPERTIES PARAMETERS UNIT FEED WATER PROPERTIES ACCORDING TO EN 12953 OPERATING PRESSURE (X) bar (= 0,1 MPa) 0,5 < X < 20 X > 20 APPEARANCE / Clean, free from suspended solids DIRECT CONDUCTIVITY AT 25°C μS/cm Not specified pH VALUE AT 25 °C (a) / > 9,2 (b) > 9,2 (b) TOTAL HARDNESS (Ca + Mg) mmol/l < 0,01 (c) < 0,01 IRON (Fe) CONCENTRATION mg/l < 0,3 < 0,1 COPPER (Cu) CONCENTRATION mg/l < 0,05 < 0,03 SILICA (SiO2 ) CONCENTRATION mg/l Not specified OXYGEN (O2 ) CONCENTRATION mg/l < 0,05 (d) < 0,02 OIL/GREASE CONCENTRATION (see EN 12953-6) mg/l < 1 < 1 ORGANIC SUBSTANCES CONCENTRATION / See footnote (e)
  • 20. 20 Figure 15 Boiler room general P&ID. The data processing schemes are standardized to the entire STEAM-MATIC SG range; further measurements and modifications are available on-demand. 4. P&ID - STEAM-MATIC SG - BOILER ROOM SG – P&ID Elements Description S1 Water Softener V1 Feed Water / Condensate Tank V2 Brine Tank V3 Chemical Dosing Station SG – P&ID Ancillaries Symbols Meaning LV Level Valve LI Level Indicator FQ Flow Indicator Totaliser PI Pressure Indicator
  • 22. 22 SG – P&ID Elements Description BDS Blowdown system (OPTION) L1 Chimney (OPTION) O2 Flue gas oxygen control system (OPTION) P1 Feed water pump P2 Second feed water pump (spare) (OPTION) TDS Automatic TDS control system (OPTION) Figure 16 STEAM-MATIC SG P&ID. Further measurements and modifications are available on-demand. 4. P&ID - STEAM-MATIC SG SG – P&ID Ancillaries Symbols Meaning AI Alarm Indicator AE Alarm Element AIC Analyzer Indicator Controller AT Analyzer Transmitter AV Analyzer Valve FC Flow Controller LV Level Valve LI Level Indicator LAH Level Alarm High LAHH Level Alarm High Above LAH LAL Level Alarm Low LALL Level Alarm Low Below LAL LIC Level Indicator Controller LSL Level Switch Low LSLL Level Switch Low Below LSL LSL/H Level Switch Low/High LSH Level Switch High LSHH Level Switch High Above LSH LT Level Transmitter M Motor PAH Pressure Alarm High PAHH Pressure Alarm High Above PAH PI Pressure Indicator PIC Pressure Indicator Controller PSH Pressure Switch High PSHH Pressure Switch High Above PSH PSV Pressure Safety Valve PT Pressure Transmitter TAH Temperature Alarm High TE Temperature Element TI Temperature Indicator TSH Temperature Switch High
  • 23. 23 SUPPLY LIMIT CANNON BONO CUSTOMER INSTRUMENTATION SYMBOLS AND IDENTIFICATION ISA S-5.1 Functions managed by “OPTISPARK” system Combustion control system Instrument air Interlock - burner shutdown Burner OPTION
  • 24. 24 4. P&ID - STEAM-MATIC SG ECO - WITH ECONOMIZER SG – P&ID Elements Description E1 Economizer BDS Blowdown system (OPTION) L1 Chimney (OPTION) O2 Flue gas oxygen control system (OPTION) P1 Feed water pump P2 Second feed water pump (spare) (OPTION) TDS Automatic TDS control system (OPTION) Figure 17 STEAM-MATIC SG ECO (with economizer) P&ID; further measurements and modifications are available on-demand. SG – P&ID Ancillaries Symbols Meaning AI Alarm Indicator AE Alarm Element AIC Analyzer Indicator Controller AT Analyzer Transmitter AV Analyzer Valve FC Flow Controller LV Level Valve LI Level Indicator LAH Level Alarm High LAHH Level Alarm High Above LAH LAL Level Alarm Low LALL Level Alarm Low Below LAL LIC Level Indicator Controller LSL Level Switch Low LSLL Level Switch Low Below LSL LSL/H Level Switch Low/High LSH Level Switch High LSHH Level Switch High Above LSH LT Level Transmitter M Motor PAH Pressure Alarm High PAHH Pressure Alarm High Above PAH PI Pressure Indicator PIC Pressure Indicator Controller PSH Pressure Switch High PSHH Pressure Switch High Above PSH PSV Pressure Safety Valve PT Pressure Transmitter TAH Temperature Alarm High TE Temperature Element TI Temperature Indicator TSH Temperature Switch High
  • 25. 25 SUPPLY LIMIT CANNON BONO CUSTOMER INSTRUMENTATION SYMBOLS AND IDENTIFICATION ISA S-5.1 OPTION Functions managed by “OPTISPARK” system Combustion control system Instrument air Interlock - burner shutdown Burner
  • 26. 26 4. P&ID - STEAM-MATIC SG PA - WITH AIR PREHEATER SG – P&ID Elements Description PA Air preheater BDS Blowdown system (OPTION) L1 Chimney (OPTION) O2 Flue gas oxygen control system (OPTION) P1 Feed water pump P2 Second feed water pump (spare) (OPTION) TDS Automatic TDS control system (OPTION) Figure 18 STEAM-MATIC SG PA (with air preheater) P&ID; further measurements and modifications are available on-demand. SG – P&ID Ancillaries Symbols Meaning AI Alarm Indicator AE Alarm Element AIC Analyzer Indicator Controller AT Analyzer Transmitter AV Analyzer Valve FC Flow Controller LV Level Valve LI Level Indicator LAH Level Alarm High LAHH Level Alarm High Above LAH LAL Level Alarm Low LALL Level Alarm Low Below LAL LIC Level Indicator Controller LSL Level Switch Low LSLL Level Switch Low Below LSL LSL/H Level Switch Low/High LSH Level Switch High LSHH Level Switch High Above LSH LT Level Transmitter M Motor PAH Pressure Alarm High PAHH Pressure Alarm High Above PAH PI Pressure Indicator PIC Pressure Indicator Controller PSH Pressure Switch High PSHH Pressure Switch High Above PSH PSV Pressure Safety Valve PT Pressure Transmitter TAH Temperature Alarm High TE Temperature Element TI Temperature Indicator TSH Temperature Switch High
  • 27. 27 SUPPLY LIMIT CANNON BONO CUSTOMER INSTRUMENTATION SYMBOLS AND IDENTIFICATION ISA S-5.1 OPTION Functions managed by “OPTISPARK” system Combustion control system Instrument air Interlock - burner shutdown Burner TDS
  • 28. 28 Figure 19 Natural gas combustion system P&ID. The data processing schemes are standardized to the entire STEAM-MATIC SG range; further measurements and modifications are available on-demand. 4. P&ID - SG - NATURAL GAS BURNER SG – P&ID Elements Description U10 Combustion air fan U11 Silencer SG – P&ID Ancillaries Symbols Meaning BALL Flame alarm low level BE Flame scanner BSLL Flame switch low level BV On/off actuated valve BZ Electrical igniter FC Frequency controller FV Flow valve M Motor PAHH Pressure alarm high high PALL Pressure alarm low low PCV Pressure control valve PI Pressure indicator PSLL Pressure switch low low VSP Gas leakage test SUPPLY LIMIT CANNON BONO CUSTOMER INSTRUMENTATION SYMBOLS AND IDENTIFICATION ISA S-5.1 OPTION Functions managed by “OPTISPARK” system Combustion control system Burner management system Instrument air Interlock - burner shutdown Burner Joint
  • 29. 29
  • 30. 30 Figure 20 Liquid fuel oil combustion system P&ID. The data processing schemes are standardized to the entire STEAM-MATIC SG range; further measurements and modifications are available on-demand. 4. P&ID - SG - LIQUID FUEL OIL BURNER (HEAVY FUEL OIL AND DIESEL OIL) SG – P&ID Elements Description U10 Combustion air fan U11 Silencer P10A Fuel oil pump P10B Fuel oil pump (spare) (OPTIONAL) E10 Fuel oil preheater SG – P&ID Ancillaries Symbols Meaning BALL Flame alarm low levef PALL Pressure alarm low low BE Flame scanner PCV Pressure control valve BSLL Flame switch low level PI Pressure indicator BV On/off actuated valve PSLL Pressure switch low low BZ Electrical igniter TAL Temperature alarm low FC Frequency controller TSL Temperature switch low FV Flow valve TIC Temperature indicator controller HV Hand valve TE Thermoelement M Motor Functions managed by “OPTISPARK” system Combustion control system (managed by “OPTISPARK”) Burner management system Interlock - burner shut down Burner Autocleaner strainer Filter “Y” type Condensate drain Sight glass Instrument air (MIN 5 bar - MAX 7) SUPPLY LIMIT CANNON BONO CUSTOMER INSTRUMENTATION SYMBOLS AND IDENTIFICATION ISA S-5.1 OPTION
  • 31. 31
  • 32. 32 Figure 21 The data processing schemes are standardized to the entire STEAM-MATIC SG range; further measurements and modifications are available on-demand. 4. P&ID - SG - NATURAL GAS + LIQUID FUEL OIL BURNER SG – P&ID Elements Description U10 Combustion air fan U11 Silencer P10A Fuel oil pump P10B Fuel oil pump (spare) (OPTIONAL) E10 Fuel oil preheater Functions managed by “OPTISPARK” system Combustion control system (managed by “OPTISPARK”) Burner management system Interlock - burner shut down Burner Joint Autocleaner strainer Filter “Y” type Condensate drain Sight glass Instrument air (MIN 5 bar - MAX 7) SUPPLY LIMIT CANNON BONO CUSTOMER INSTRUMENTATION SYMBOLS AND IDENTIFICATION ISA S-5.1 OPTION SG – P&ID Ancillaries Symbols Meaning BALL Flame alarm low levef PCV Pressure control valve BE Flame scanner PI Pressure indicator BSLL Flame switch low level PAHH Pressure alarm high high BV On/off actuated valve PSLL Pressure switch low low BZ Electrical igniter TAL Temperature alarm low FC Frequency controller TSL Temperature switch low FV Flow valve TIC Temperature indicator controller HV Hand valve TE Thermoelement M Motor VSP Gas leakage test PALL Pressure alarm low low
  • 33. 33
  • 34. 34 5. BOILER LAYOUT - BOILER ROOM Figure 22 A sample installation of a SG STEAM-MATIC inside a boiler room, plan view 4 1 2 8002500 15001500 min.800450 600 1500 350 * * ** 15005600 5 prof.Z 20x3 Round bar 10 Flat bar 80X8 Chequered plate elev. 0.0 every ~2 mt. 500 650
  • 35. 35 1 Steam Boiler SG 2 Water-condensate storage tank 3 Structure supporting tank 4 Feed water treatment unit 5 Steam header 6 Chimney Figure 23 A sample installation of a SG STEAM-MATIC inside a boiler room, front view 3 1002500min. min.1500 100 710 500 min.2000* 1 2 4 6
  • 36. 36 6. INSTALLATION “Steam-Matic” generator is shipped ready to operate after a fire test in our factory. For installation local State regulation must be observed. Examine the boiler on arrival to control if it has suffered any damage during transport. Any damage should be notified to the carrier. The “Steam-Matic” boiler should be placed on a well leveled concrete floor. Minimum clearance must be allowed: - rear side min : 1,5 m. for inspection - front side min : sufficient distance for tube cleaning and burner extraction - left side min : 1,5 m. to allow auxiliaries control - right side min : 0,8 m. for inspection The boiler room will be kept clean and well ventilated (indicatively 1 m3 per 1 MW of thermal capacity); a mini- mum of two opening is required to provide sufficient air for the burner and avoid excessive room temperature. Flooring The generator must rest on a strong and levelled floor, the floor slab must be dimensioned to support spe- cific loads up to 25 N/cm2 and to support the total weight of the generator and its accessories in the full load condition. The following connections are required. Boiler piping - Steam line to the boiler valve - Safety valves piped to atmosphere with the same diameter as the safety valves outlet and with adeguate supports to prevent stress on valves. - Bottom and surface blowdown connection piped a drain flash tank - Water column and sight glass drain piped for blowdown Flue gas outlet The generator is supplied with carbon steel counterflange on the fumes exhaust connection, which the in- staller can use to weld the fumes pipe or the vertical flue. The fumes connection is dimensioned to support the weight of the flue overlaying for a maximum height of 10 metres from the floor surface (considering the flue pipe realised in steel with thickness of 6 mm). Horizontal loads and moments must be avoided. For applications that do not lie within the previously described cases, consult the Bono Energia Technical Dept. Steam connection It shall connect the steam main valve to the steam header. The piping must allows the thermal expansions in order to avoid stress on the valve. If the utilities pressure is less than the generator operating pressure or if a constant pressure is required it is necessary to install a reducing valve provided with by-pass.
  • 37. 37 Water and condensate piping The water tank receives the condensate and treated water. The float valve controls the treated water inlet; up- stream the float valve it is advisable to install an gate valve to allow removal of float valve for maintenance pur- poses. In the tank upper section there are the vent and the condensate flanges. The over flow and blowdown connections are placed on the tank too. A filter is installed on the feed water pump suction side to pro¬tect the pump. The pipe must be as straight as possible. The height of the feed tank must assure the necessary head to a¬void pump cavitation and consequent insufficient water feed. Oil piping (if any) The main tank must be installed according to the Local Authority Specification. It is necessary to heat the oil on the tank outlet to facilitate the pumping during cold seasons. The pre-heating temperature is about 40-60°C. Electrical tracing of heavy fuel oil lines is required to keep the oil at constant temperature while pumped. Safety valves Safety valve discharge has to be vented to atmosphere with a tube of same diameter than valve outlet at least following the most direct way. The discharge pipe must be provided, at its lowest point with a condensate drain pipe and must be adequately supported and free to expand without stress on the valves. ELECTRIC POWER CONNECTION Connect electric line to RST terminals in boiler panel according to wiring diagram. Check that line voltage is within + 5% of nominal value. The general 3 phase switch, shall be provided and installed preferably outside the boiler room. HYDRAULIC TEST If hydraulic test is required, proceed as follows in order to prepare the generator for the hydraulic test: - Exclude the safety valves by placing a steel disk with suitable thickness between the flanges and close the boiler valves. - Close the pressure-switch on-off cock to prevent any damage to the internal parts. - Remove the outlet cap from the level indicator and make the connection to the hand pump. - Fill the generator with purified water using the boiler feed pump. Remember, in the event of a centrifugal pump, narrow the pump delivery in order to limit motor absorption. As for a single-impeller feed pump, the delivery valve must be open. - During the filling phase vent the air through the vent valve until water flows out; then close the vent valve. - When filling has been completed, make sure that the 3-way cock connected to the boiler manometer is open, pressurise the boiler with the centrifugal pump and then with the hand pump until the prescribed hydraulic test pressure is reached.
  • 38. 38 BOILER START UP Boiler Filling When filling the boiler, the water must appear just above the normal level (block) in a way to allow successive expansion when the water itself is heated. At least one vent valve must be left open during the filling phase to prevent pressurisation of the boiler due to the effect of the air it contains; the operator must monitor the pressure trend carefully and stop the pump if any anomalies are detected. Boiler must be filled slowly, in particular if water is hot, so that no dangerous stress occurs in pressure parts. If boiler is partially filled, temperature of new water that is introduced shall be not higher or lower than 25 °C than temperature of water already present in the boiler. Usually water temperatury should not less than 20°C for filling operation; if temperature is higher than 40°C filling must be carried out with extreme precautions. IMPORTANT: drain levels and look at the filling to verify cleanliness and operation. For filling use only wa- ter with suitable characteristics Preliminary operations Before starting the boiler check that all auxiliary devices have been tested. The following procedure is a summarised list of main controls to be carried out before starting up: • check water level on level gauges: the level must be 30 mm over the block value • check level gauges opening drains and looking at refilling • check regulation valves drains and vents • check safety valves installation and verify congruence between set point and stamp pressure of valves • check minimum position of combustion air damper • check all flanged connections and gaskets presence and check all bolts • check that the man hole and the inspection hatches are closed with the bolts tightened and the gaskets in position; • check that the requested quality of hot water is available • check all safety logics and interblocks and check all safety instruments ATTENTION: if any of above checks has negative result do not start up boiler. 6. INSTALLATION
  • 39. 39 STARTING UP After carrying out above operations boiler can be started up. Burner operation and combustion shall be controlled during start up; air / fuel ratio shall be set in respect of flue gas analysis at different loads. CO content shall be limited within local law requirements. Burner shall be ignited following relevant instructions and with strict respect of safety instructions consider- ing also of fuel type Boiler must be at minimum until steam flows from vent valve; from this situation is possible to closo vent valve and increase pressure. Pressure shall be increased with burner low load. ATTENTION: too rapid temperature increase can create dangerous sress conditions and cause cracks STEAM PRODUCTION When set pressure is reached with boiler at minimum load, load can be increased and control can be set for automatic operation. ATTENTION: the system shall be kept continuously controlled until MCR has been reached to verify that no defects in safety system is present. NORMAL OPERATION When boiler begins maximum load production it is necessary to verify normal conditions for continuos eco- nomical and safe operation. Temperatures, pressure capacities shall be measured with precision and conti- nuity and shall be compared with design figures; in particular flue gas temperature is directly associated with efficiency: an increase of this temperature is a decrease of efficiency. An increase of pressure in combustion air / flue gas system indicate that flue gas channels are dirty and clean- ing operation is urgently needed. It is advisable to record all measures on a log book and in particular: • fuel consumption • flue gas analysis • flue gas temperature • air / flue gas pressure • operation time and load • any other useful note necessary to create a databank of the boiler.
  • 40. 40 During boiler operation a particular attention shall be paid to A) Boiler water level The normal water level in the boiler must be maintained at all times. If this is too high, water may be dragged into the steam, thus compromising its purity. If the level is too low, the boiler pipes may overheat or, in ex- treme cases, break. When in very low conditions, switch the fires off immediately and look for the causes of this situation before igniting again. ATTENTION: If level is below minimum stop immediately the burner and in any case do not refill with cold water the boiler. The furnace may explode immediately. Levels gauges and switches shall be always perfectly efficient; level gauges shall be drained at any periodical personnel rotation to verify cleanliness. Level gauges purge shall be carried out full opening slowly drain cocks and closing them looking at refilling: if water is drained too slowly repeat operation to purge levels from dirty. B) Water treatment and continuous blow down (see also Table 4) The chemical treatment of the feed water, the conditioning of the boiler water and the regulation of the con- centration of the salts in the boiler water must be set accurately, as soon as the new boiler is used. Blow down capacity shall be directly connected to total salt concentration in boiler water: periodical chemical analysis of boiler water are necessary to define exact capacity of blow down C) Combustion Efficient combustion is fundamental for good boiler operation: bad combustion can cause the production of unburned fuels, thus compromising boiler performance along with the formation of carbon deposits on the inner surfaces of the pipes with consequent dirtying (and further penalisation of performance). Therefore combustion shall be monitored continuously. In general good combustion is obtained with perfect air distribution in the burner: the position of the air swirler shall be correct and checked periodically. ATTENTION: it is absolutely necessary to respect all instructions of burner manufacturer during start up, normal operation and shut down of the burner. In particular it is always necessary to purge combustion chamber (with combustion air) before any burner start-up. Combustion shall be optimised verifying air /fuel ratio (air excess) at any boiler and burner load. Air excess measurement can be performed by means of a flue gas oxygen content analysis; too high air excess causes efficiency reduction. It is therefore necessary to periodically analyse the fumes released into the flue, in order to verify the correct maintenance of the operating parameters. 6. INSTALLATION
  • 41. 41 BOILER SHUTDOWN When the boiler is stopped, the burner and the air fan must be put out of service following the Standards inher- ent the combustion system used. Particular attention must be paid to the conditions in which the combustion system is left. When the burner has been switched off, the air fan must be left in service in order to complete cleaning of the combustion chamber and eliminate any trace of unburned fuel residues and then stopped. The boiler must be left to cool down slowly as uniformly as possible. Accelerating cooling of the combustion chamber by allowing large masses of cold air to pass through the plant could lead to damage of the refractory materials and useless tensions in the pressurised parts. Later, when the refractory materials have reached lower temperatures, the use of a small air flow through the burner will be allowed. At this point, the pressure in the boiler must be left to decrease naturally, without with- drawing steam or opening the valves. When the pressure has dropped below 1 bar, a vent valve can be opened. When it is necessary to empty the boiler, boiler water temperature shall be below 100°C before openig boilers drains. ATTENTION: before opening drains check if vent valve is opened to avoid vacuum condition in the boiler. When the boiler has been fully drained inernal inspection can be performed.
  • 42. 42 7. SCOPE OF SUPPLY - STANDARD EQUIPMENT STANDARD EQUIPMENT - STEAM-MATIC SG BOILER PRESSURE VESSEL Cylindrical furnace fitted with expansion joints up to model SG 1200 (corrugated type from model SG 1500) Shell equipped with manholes, inspection and cleaning doors, flanged doors, steam outlet branch Moisture separator Front and rear tube plates dished type, butt-welded to the shell and the furnace Smoke tubes expanded and welded to the tube plates, internal turbulator system Flanged connection for self-supporting stack, with counterflange Water tube reversing chamber with upper and lower headers welded to the rear tube plate INSULATION AND EXTERNAL LAGGING Insulation of the external casing in mineral wool panels, stainless steel external lagging BASE Base frame made with iron bars VALVES AND ACCESSORIES Main steam valve (manual) N.2 Pressure safety valves Shell blow down valve (surface) N.2 Level indicators, with shut-off valve N.2 Shell drain valves N.2 Reversal chamber blow down valves Flue gases thermoelement at the stack base Flue gases sampling point at the stack base Rear flame sight hole WATER FEEDING GROUP Multi stage centrifugal pump (horizontal design) On-off valve Level regulation system with 1 pc. modulating pneumatic valve Check valve
  • 43. 43 STANDARD EQUIPMENT - STEAM-MATIC SG BURNING SYSTEM (modulating regulation) Burner box Flame scanner Observation port for flame control Air swirler Combustion air fan Burning ignition torch NATURAL GAS FUEL (NG) Natural gas pressure gauge Internal gas header with multi-nozzle system N.2 Feeding gas train electrically actuated shut-off valves Feeding gas electrically actuated regulating valve N.2 Burning ignition safety solenoid valves HEAVY FUEL OIL (HFO) Fuel pump station, complete with on/off valve Preheating station steam-electrical thermoregulation system DIESEL OIL (DO) Fuel pump station, complete with on/off gate valve SAFETY AND CONTROL EQUIPMENT FOR THE BOILER Burner management system for burner ignition and flame control BMS (safety automatic device) Safety pressure switch for minimum air combustion pressure Temperature regulation system (only heavy fuel oil) Gas leakage test- VPS (only gas fuel) N.2 Max/min fuel pressure switches Steam pressure transmitter Shut-down pressure switch for max steam pressure Automatic pressure modulating control regulator Automatic modulating level control regulator ELECTRIC WIRING With flexible conduits and tight terminal fittings for high mechanical resistance and water proof sealing ELECTRIC PANEL Steel cabinet, oven painting, front door, IP54 protection Power section, main switch and door locking device, magneto-thermal switches to protect each power user, tropicalized power contactors Control auxiliary section, ignition and flame control panel, alarms and shut-down logic, alarm horn contacts, auxiliaries protection fuses Operators panel, burner START/STOP switch/indicator, feed pump START/STOP switch/indica- tor, alarms acknowledgement with lamps TYPEOFFUELAVAILABLE* * dual fuel burning systems are available (NG + HFO, NG + DO) and include the burning system equipment above listed for each fuel type.
  • 44. 44 7. SCOPE OF SUPPLY - OPTIONAL EQUIPMENT OPTIONAL EQUIPMENT* - STEAM-MATIC SG ECONOMISER (FOR HIGH EFFICIENCY UP TO 95%) Package unit bult-in the front side of the generator structure insulation Carbon steel tube bundle made of finned tubes and elbows Set of headers for water inlet and outlet N.2 Inspection and maintenance upper doors SET OF INSTRUMENTS FOR ECONOMISER Vent valves Drain valve N.2 Temperature gauge for inlet and outlet temperature N.2 Shut-off manual valves N.2 Pressure points Safety valve By pass valve (manual) AIR PREHEATER (FOR HIGH EFFICIENCY UP TO 92%) Package unit bult-in the front side of the generator structure Double vertical carbon steel tubes bank, with flue gases running inside and air running outside the tubes. N.2 Inspection and maintenance upper doors SECOND FEED WATER PUMP AS SPARE (Installed on boiler base frame and connected to the boiler skid) Multi stage centrifugal pump (horizontal design) On-off valve Check valve FEEDING PUMP SPEED CONTROL SYSTEM (available for each pump) Feeding pump speed control system (drived by electrical inverter) Feed water pressure control loop COMBUSTION AIR FAN SPEED CONTROL SYSTEM Electrical inverter SPARE FUEL PUMP Spare fuel pump (available for liquid fuel burner) AUTOMATIC BOILER CONTROL SYSTEM «OPTISPARK» BONO Optispark industrial boilers management and control automatic system Flue gas oxygen control system with separated probe Control system of the air/fuel ratio (SRC) and of the supply of oxygen (electric cam)
  • 45. 45 OPTIONAL EQUIPMENT* - STEAM-MATIC SG «SAFESPARK» SYSTEM (24 HOUR) System for 24 hour boiler operating without human presence according to EN 12953 Directive N.2 Automatically controlled minimum level probes with periodical test, complete with switch Automatically controlled high level probes with periodical test, complete with switch Upgraded photocell, with automatically controlled periodical test “SAFESPARK” SYSTEM (72 HOUR) System for 72 hour boiler operating without human presence according to EN 12953 Directive N.2 Automatically controlled minimum level probes with periodical test, complete with switch Automatically controlled high level probes with periodical test, complete with switch Upgraded photocell, with automatically controlled periodical test Automatic TDS control system Automatic blowdown TDS CONTROL SYSTEM Automatic TDS control system (already included in “SAFESPARK” system 72 hour) AUTOMATIC BLOW-DOWN SYSTEM Automatic blowdown system (already included in “SAFESPARK” system 72 hour) LADDER AND PLATFORM Ladder and platform THERMO - PHYSI- CAL DEAERATOR (ATMOSPHERIC OR LOW-PRESSUR- IZED) Cylindrical body in carbon steel Set of flanged connections Support frame in carbon steel Water on-off automatic valve Feed water distribution system Level indicator Drain connection Drain valve Degassing tower (for low-pressurized deaerator) WATER SOFTENER Water softening station DUPLEX type (other types on request) CHEMICAL DOSING STATION Chemical dosing station (pH conditioner, oxygen scavenger) BLOWDOWN VESSEL Blowdown vessel STEAM SUPERHEATER Shell and tube configuration that heats the saturated steam coming from the cylindrical drum, exchan- ging heat with the fumes, complete with safety valve and thermostat. STEAM HEADER Steam header collecting system CHIMNEY Chimney complete with duct to connect boiler’s flue gas outlet, basaplate structure, cylindrical structure shell and anchor points to fix wool panels for insulation * complete list of all available components on request
  • 46. 46 8. APPENDIX 1. FUEL CONSUMPTION CALCULATION We assume that we have to calculate natural gas fuel consumption for the production of 5500 kg/h of saturated steam, working pressure is 13 bar, the fire tube steam boiler is a STEAM-MATIC SG 600 with economizer. Feed water temperature is 90 °C. As nominal steam production of the fire tube steam boiler STEAM-MATIC SG 600 is 6000 kg/h, while actual steam produc- tion is 5500 kg/h, we calculate the load with the following equation (feed water T = 90 °C)- According the graphic regarding the coefficient of performance (COP) of the steam boiler STEAM-MATIC SG ECO, equipped with economizer crossed with load (see Figure 14), we define that COP is 94,7%. In accordance with heat balance equation Q = M steam * (hg-he)/3600, where: Q – heat needed to achieve saturated steam production with the above indicated characteristics (watt); M steam - steam production (t/h); hg – enthalpy of saturated steam at the above indicated steam pressure and water temperature (kcal/kg); he – enthalpy of feeding water at the above indicated water temperature (kcal/kg); According to the table of thermodynamic characteristics of water and saturated steam (Appendix 2), we define value hg under 13 bar pressure gauge and he with 90 °C. Actual useful thermal load is defined by the relation: Q actual useful = 5 500 * (666,8 – 90,0) = 3 172 400 kcal/h. Total thermal power in the burner is defined by the equation: Q burner = Q actual useful / (COP,%/100), Q burner = 3 172 400/(94,7/100) = 3 349 947 kcal/h. Fuel heat capacity of natural gas is 8500 kcal/Nm3. We define fuel consumption per hour of natural gas under normal conditions from the relation: 3 349 947/8 500 = 394 Nm3/h. Load, % = * 100% Load, % = * 100% = 92% 6000 5500 91 92 93 94 95 96 25 50 75 100 Efficiency% % Load Efficiency at 10 bar Efficiency at 13 bar Efficiency at 16 bar
  • 47. 47 9. APPENDIX 2. THERMODYNAMIC CHARACTERISTICS OF SATURATED STEAM Pm Pa T V he r hg bar kg/cm2 bar kg/cm2 K °C m3 /kg kJ/kg kcal/kg kJ/kg kcal/kg kJ/kg kcal/kg 0,050 0,051 306,05 32,9 28,191 137,7 32,9 2425 679,2 2562,7 612,1 0,100 0,102 318,95 45,8 14,674 191,8 45,8 2394,4 571,9 2586,2 617,7 0,150 0,153 327,15 54,0 10,023 225,9 54,0 2374,8 567,2 2600,7 621,2 0,200 0,204 333,15 60,0 7,65 251,5 60,1 2359,7 563,6 2611,2 623,7 0,250 0,255 338,15 65,0 6,204 272,0 65,0 2347,5 560,7 2619,5 625,7 0,300 0,306 342,25 69,1 5,229 289,3 69,1 2337,5 558,3 2626,8 627,4 0,350 0,357 345,85 72,7 4,526 304,3 72,7 2328,7 556,2 2633 628,9 0,400 0,408 349,05 75,9 3,994 317,6 75,9 2320,7 554,3 2638,3 630,2 0,450 0,459 351,85 78,7 3,577 329,6 78,8 2313,6 552,6 2643,2 631,4 0,500 0,510 354,45 81,3 3,240 340,5 81,4 2306,9 551,0 2647,4 632,4 0,6 0,612 359,05 85,9 2,732 359,9 86,0 2295,2 548,2 2655,1 634,2 0,7 0,714 363,05 89,9 2,365 376,7 90,0 2284,3 545,6 2661,0 635,6 0,8 0,816 366,65 93,5 2,087 391,7 93,6 2275,5 543,5 2667,2 637,1 0,9 0,918 369,85 96,7 1,869 405,2 96,8 2267,2 541,5 2672,4 638,3 1,0 1,020 372,75 99,6 1,694 417,5 99,8 2259,2 539,6 2676,7 639,4 0 0 1,013 1,033 373,15 100,0 1,673 419,1 100,1 2258,4 539,4 2677,5 639,5 0,05 0,051 1,063 1,084 374,55 101,4 1,601 425,0 101,5 2254,2 538,4 2679,1 639,9 0,10 0,102 1,113 1,135 375,75 102,6 1,533 430,4 102,8 2251,2 537,7 2681,6 640,5 0,15 0,153 1,163 1,186 378,25 105,1 1,471 435,8 104,1 2247,9 536,9 2683,7 641,0 0,20 0,204 1,213 1,237 379,35 106,2 1,414 440,9 105,3 2245,0 536,2 2685,8 641,5 0,30 0,306 1,313 1,339 380,55 107,4 1,312 450,5 107,6 2238,7 534,7 2689,2 642,3 0,40 0,408 1,413 1,441 382,65 109,5 1,225 459,7 109,8 2232,8 533,3 2692,5 643,1 0,50 0,510 1,513 1,543 384,75 111,6 1,149 468,5 111,9 2227,0 531,9 2695,5 643,8 0,60 0,612 1,613 1,645 386,65 113,5 1,038 476,5 113,8 2221,5 530,6 2698,0 644,4 0,70 0,714 1,713 1,747 388,55 115,4 1,024 484,4 115,7 2216,9 529,5 2701,3 645,2 0,80 0,816 1,813 1,849 390,25 117,1 0,971 491,9 117,5 2211,9 528,3 2703,8 645,8 0,90 0,918 1,913 1,951 391,95 118,8 0,923 499,1 119,2 2206,9 527,1 2705,9 646,3 1,00 1,020 2,013 2,053 393,55 120,4 0,881 505,8 120,8 2202,3 526,0 2708,0 646,8 Pm - gauge pressure Pa - absolute pressure T – temperature V - specific volume he - specific enthalpy of water r - specific enthalpy of evaporation of steam hg - specific enthalpy of saturated steam Denomination
  • 48. 48 Pm Pa T V he r hg bar kg/cm2 bar kg/cm2 K °C m3 /kg kJ/kg kcal/kg kJ/kg kcal/kg kJ/kg kcal/kg 1,00 1,020 2,013 2,053 393,55 120,4 0,881 505,8 120,8 2202,3 526,0 2708,0 646,8 1,10 1,122 2,113 2,155 395,05 121,9 0,841 512,5 122,4 2198,5 525,1 2711,0 647,5 1,20 1,224 2,213 2,257 396,55 123,4 0,806 519,2 124,0 2194,3 524,1 2713,5 648,1 1,30 1,326 2,313 2,359 398,05 124,9 0,773 525,0 125,4 2190,1 523,1 2715,1 648,5 1,40 1,428 2,413 2,461 399,45 126,3 0,743 530,9 126,8 2186,3 522,2 2717,2 649,0 1,50 1,530 2,513 2,563 400,75 127,6 0,714 536,3 128,1 2181,7 521,1 2718,1 649,2 1,60 1,632 2,613 2,664 402,05 128,9 0,689 542,2 129,5 2178,8 520,4 2721 649,9 1,70 1,733 2,713 2,766 403,25 130,1 0,665 547,2 130,7 2175 519,5 2722,3 650,2 1,80 1,835 2,813 2,868 404,55 131,4 0,643 552,7 132,0 2171,3 518,6 2723,9 650,6 1,90 1,937 2,913 2,970 405,65 132,5 0,622 557,7 133,2 2167,9 517,8 2725,6 651,0 2,00 2,039 3,013 3,072 406,85 133,7 0,603 562,7 134,4 2164,6 517 2727,3 851,4 2,20 2,243 3,213 3,278 409,05 135,9 0,568 571,9 136,6 2158,3 515,5 2730,2 652,1 2,40 2,447 3,413 3,480 411,15 138,0 0,536 581,1 138,8 2152 514,0 2733,1 652,8 2,60 2,651 3,613 3,684 413,15 140,0 0,509 589,5 140,8 2146,2 512,6 2735,7 653,4 2,80 2,855 3,813 3,888 415,05 141,9 0,483 597,9 142,8 2140,3 511,2 2738,2 654,0 3,00 3,059 4,013 4,092 416,85 143,7 0,461 605,8 144,7 2134,8 509,9 2740,7 654,6 3,20 3,263 4,213 4,296 418,55 145,4 0,44 612,9 146,4 2129,4 508,6 2742,4 655,0 3,40 3,467 4,413 4,500 420,35 147,2 0,422 620,5 148,2 2124,4 507,4 2744,9 655,6 3,60 3,671 4,613 4,704 421,95 148,8 0,405 627,6 149,9 2118,9 506,1 2746,5 656,0 3,80 3,875 4,813 4,908 423,55 150,4 0,389 634,3 151,5 2114,3 505,0 2748,6 656,5 4,00 4,079 5,013 5,112 425,15 152,0 0,374 641,0 153,1 2109,3 503,8 2750,3 656,9 4,20 4,283 5,213 5,316 426,55 153,4 0,361 647,3 154,6 2104,7 502,7 2752,0 657,3 4,40 4,487 5 413 5,520 427,95 154,8 0,348 653,6 156,1 2100,1 501,6 2753,7 657,7 4,60 4,691 5,613 5,724 429,35 156,2 0,336 659,8 157,6 2095,9 500,6 2755,8 658,2 5,00 5,099 6,013 6,131 432,05 158,9 0,315 671,1 160,3 2087,1 498,5 2758,3 658,8 5,50 5,608 6,513 6,641 435,25 162,1 0,292 685,0 163,6 2077,1 496,1 2762,0 659,7 6,00 6,118 7,013 7,151 438,15 165,0 0,272 697,9 166,7 2067,4 493,8 2765,4 660,5 6,50 6,628 7,513 7,661 440,95 167,8 0,255 710,1 169,6 2058,2 491,6 2768,3 661,2 7,00 7,138 8,013 8,171 443,65 170,5 0,240 721,8 172,4 2049,0 489,4 2770,8 661,8 7,50 7,648 8,513 8,681 446,15 173,0 0,227 733,1 175,1 2040,6 487,4 2773,8 662,5 8,00 8,158 9,013 9,191 448,55 175,4 0,215 743,6 177,6 2032,3 485,4 2775,8 663,0 9. APPENDIX 2. THERMODYNAMIC CHARACTERISTICS OF SATURATED STEAM
  • 49. 49 Pm Pa T V he r hg bar kg/cm2 bar kg/cm2 K °C m3 /kg kJ/kg kcal/kg kJ/kg kcal/kg kJ/kg kcal/kg 8,50 8,667 9,513 9,700 450,85 177,7 0,204 753,6 180,0 2024,3 483,5 2777,9 663,5 9,00 9,177 10,013 10,210 453,15 180,0 0,194 763,3 182,3 2016,4 481,6 2779,6 663,9 9,50 9,687 10,513 10,720 455,25 182,1 0,185 772,9 184,6 2008,8 479,8 2781,7 664,4 10,00 10,197 11,013 11,230 457,25 184,1 0,177 782,1 186,8 2001,3 478,0 2783,4 664,8 11,00 11,217 12,013 12,250 481,15 188,0 0,163 799,3 190,9 1987,1 474,6 2786,3 665,5 12,00 12,236 13,013 13,269 464,85 191,7 0,151 815,6 194,8 1973,7 471,4 2789,2 666,2 13,00 13,256 14.013 14,289 468,25 195,1 0,141 831,1 198,5 1960,7 468,3 2791,8 666,8 14,00 14,276 15,013 15,309 471,45 198,3 0,132 845,7 202,0 1948,1 465,3 2793,9 667,3 15,00 15,296 16,013 16,328 474,55 201,4 0,124 859,6 205,3 1936,4 462,5 2795,9 667,8 16,00 16,315 17,013 17,348 477,55 204,4 0,117 872,9 208,5 1924,7 459,7 2797,6 668,2 17.00 17,335 18,013 18,368 480,35 207,2 0,110 885,5 211,5 1913,4 457,0 2798,9 668,5 18,00 18,355 19,013 19,388 483,05 209,9 0,105 897,6 214,4 1902,5 454,4 2800,1 668,8 19,00 19,374 20,013 20,407 485,65 212,5 0,100 909,4 217,2 1891,6 451,8 2801,0 669,0 20,00 20,394 21,013 21,427 488,15 215,0 0,095 921,1 220,0 1881,5 449,4 2802,6 669,4 21,00 21,414 22,013 22,447 490,45 217,3 0,090 932,0 222,6 1871,5 447,0 2803,5 669,6 22,00 22,433 23,013 23,466 492,75 219,6 0,087 942,4 225,1 1861,5 444,6 2803,9 669,7 23,00 23,453 24,013 24,486 494,95 221,8 0,083 952,9 227,6 1851,4 442,2 2804,3 669,8 24,00 24,473 25,013 25,506 497,15 224,0 0,080 963,0 230,0 1842,2 440,0 2805,2 670,0 25,00 25,493 26,013 26,525 499,25 226,1 0,077 972,6 232,3 1832,6 437,7 2805,2 670,0 26,00 26,512 27,013 27,545 501,25 228,1 0,0741 981,3 234,3 1821,6 435,0 2802,9 669,3 27,00 27,532 28,013 28,565 503,25 230,1 0,0714 990,5 236,5 1812,5 432,8 2803,0 669,4 28,00 28,552 29,013 29,585 505,15 232,0 0,0690 999,6 238,7 1803,6 430,7 2803,2 669,4 29,00 29,571 30,013 30,604 507,05 233,9 0,0667 1008,4 240,8 1794,9 428,6 2803,3 669,4 30,00 30,591 31,013 31,624 508,85 235,7 0,0645 1017,1 242,9 1786,2 426,5 2803,3 669,4 Pm - gauge pressure Pa - absolute pressure T – temperature V - specific volume he - specific enthalpy of water r - specific enthalpy of evaporation of steam hg - specific enthalpy of saturated steam Denomination
  • 50. 50 10. APPENDIX 3. STEAM-MATIC SG SPECIAL EXECUTIONS This section is dedicated to special executions of STEAM-MATIC SG firetube steam boilers, showing few examples of the great variety of solutions that BONO can provide to the customer. These are clear examples of the attention paid to the customers’ needs and the high level of quality standards and customization of the design and production of industrial steam boilers by BONO ENERGIA. Figure 24 3D model of a special execution of a supplied STEAM-MATIC SG fire tube steam boiler. The particularity of the equipment is its capacity to guaran- tee more than 99% efficiency rate; this is possible due to the condensation technology introduced. The result of this solution is the optimization of the combustion fumes’ temperature (avoiding acid condensation at the chimney) and the production of steam and hot water at a proper temperature accor- ding to the brewing processes.
  • 51. 51 Figure 25 Picture of the supplied STEAM-MATIC SG fire tube steam boiler, with an effective steam capacity of 20 ton/h at 15 bar, with efficiency rate above 99%. Field of application is a brewery, the boiler can be fuelled with natural gas, heavy fuel oil and a combination of natural gas and biogas, which is produced during the processes.
  • 52. 52 10. APPENDIX 3. STEAM-MATIC SG SPECIAL EXECUTIONS Figure 26 3D drawings of STEAM-MATIC SG steam boilers, 20 t/h, 15 bar fuelled with natural gas and heavy fuel oil. Each one of the three boilers is complete with air preheaters, to achieve thermal efficiency up to 93%, and heat exchanger, to produce superheated water from steam. The supply includes deaerator and water treatment plant. This customized thermal plant’s field of applica- tion is district heating.
  • 53. 53
  • 54. 54 STEAM BOILERS » UNI-MATIC UM FLASH COIL STEAM GENERATORS Applications: food & beverage, textile industry, plastics and rubber industry, woodworking, laundries Steam production: from 0.3 to 3 t/h Pressure: up to 12 bar » STEAM-MATIC SM and SG FIRE TUBE STEAM BOILERS Applications: pulp and paper industry, food & beverage, district heating, plastics and rubber industry, chemicals and petrochemical industry, textile Steam production: from 1 to 25 t/h Pressure: from 12 to 30 bar » CLAJTUB CTD WATER TUBE STEAM BOILERS Applications: chemical processes, refinery, petrochemical industry, power generation utilities, sugar refineries Steam production: up to 180 t/h Pressure: up to 80 bar Temperature: up to 480 °C » HRSG HEAT RECOVERY STEAM GENERATORS Applications: paper mill, chemical and pharmaceutical, district heating, cogeneration, textile Steam production: up to 40 MW From gas turbine: from 3 to 15 MW (el.), from engine: from 3 to 20 MW (el.) STEAM-MATIC SG CLAJTUB CTD UNI-MATIC UM 11. APPENDIX 4. BONO ENERGIA PRODUCT RANGE
  • 55. 55 THERMAL FLUID HEATERS » OIL-MATIC OMV THERMAL FLUID HEATERS, MULTI-COIL TECHNOLOGY Applications: typography, cosmetics industry, wood & paper, chemical industry, petrochemical Thermal capacity: 0.2 to 6 MW Fluid temperature: up to 350 °C » OIL-MATIC OMP THERMAL FLUID HEATERS, MULTITUBULAR Applications: pharmaceutical, petrochemical Thermal capacity: from 1.7 to 17 MW Temperature: up to 350 °C » OIL-MATIC HTH HIGH TEMPERATURE THERMAL FLUID HEATERS Applications: district heating, oil & gas, others Thermal capacity: from 2 to 35 MW Temperature: up to 400 °C SUPERHEATED WATER BOILERS » CTH MULTITUBULAR SUPER HEATED WATER GENERATORS Applications: district heating and others Thermal capacity: up to 40 MW package: up to 80 MW - field erected Temperature: over 100 °C, up to 260 °C » SM-ASA, SG-ASA FIRE TUBE SUPERHEATED WATER BOILERS Applications: district heating and others Thermal capacity: from 0.7 to 17 MW Temperature: over 100 °C OIL-MATIC OMV CTH OIL-MATIC OMP
  • 56. Bono Energia S.p.A Via Resistenza 12 - 20068 Peschiera Borromeo (Mi) - Italy Phone +39 0255302848 - Fax +39 025471955 www.bono.it Ed. N°1 DISCLAIMER: All the data presented in this technical book are indicative and subject of changing due to product customization and innovation processes. They must be considered by the user only at the first stage of product selection; CANNON BONO declines any responsibility for wrong usage of mentioned data and invites the user to contact our commercial department for further details.