MODULAR OT
Operation theatre is that specialized facility of the hospital where life
saving or life improving procedures are carried out on the human body
by invasive methods under strict aseptic conditions in a controlled
environment by specially trained personnel to promote healing and
cure with maximum safety, comfort and economy. It is imperative that
operation theatre (OT) is designed scientifically to ensure sterility, easy
maintenance and effective utilization. A civil – mechanical –electrical –
electronic – biomedical combination driven and co-ordinated by needs
, preferences and safety of the medical surgical team forms the basis
of planning , starting and maintaining an operation theatre.
• VARIOUS COMPONENTS OF MODULAR AND SEMI MODULAR OT
• Antistatic Flooring - ESD vinyl
The flooring confirm to following standards
• EN 1081/IEC 613404, EN 1815 & EN 12466.Solid vinyl tile (SVT)(2mm).
• 2.00mm, total weight 3.0 g/m2 polyurethane reinforced ,scratch resistant, fire
resistant, chemical resistant , slip resistant, anti-fungi & bacterial growth ,
dimensional stability ≤0.40%, static electrical charger < 2Kv , impact sound
reduction approx. +4bd, electrical resistant.
Operation theatre control panel , surgeon control panel
All the controls within the theatre should be located on a control panel mounted recessed in the
theatre wall. The panel will incorporate all the necessary controls for the correct operation and
monitoring of equipment and services within the operating theatre. Each control panel shall contain:
• Display & control for Temp & humidity.
• Control of Venetian blinds in windows & doors.
• Status Indication of up to 5 Medical Gases + 1 Vacuum.
• On/Off and regulation of Intensity of illumination in OT.
• Digital Display of Real Time / Elapsed time
• Intercom with speaker & microphone.
• Microprocessor controlled Liquid Crystal Text Backlit display with 4 lines of 20 characters each.
• There should be five illuminated buttons for Test, acknowledge, scroll, text & Menu.
• Audio-visual alarms.
• Normal, Warning & Alarm LED indications.
Certificate of country of origin and manufacturers test certificates to be submitted after
installation
Over Flow Port
 Provided in theatre to prevent cross contamination of air from clean
and dirty areas.
 Over flow port will be strategically placed, enable differential room
pressure to be maintained and ensure that when doors are opened
between clean and dirty area.
 Over flow port, made of Stainless Steel 1.4301 (SS 304 grade)
 Have filter element, which should be openable & cleanable.
 Volume to be exhausted be between 175m3/h to 200m3/h.
Certificate of country of origin and manufacturers test certificates to
be submitted after installation
Laminar air flow
One of the main objectives of any operating theatre system is
to dilute the bacteria generated by the operating team and
patient in the theatre and to create an Air flow pattern that
carries contaminated air away from the operating table &
entering surgical wounds. A Laminar Flow System should
contain three basic elements – a blower, a high efficiency air
filter and a Plenum with a diffuser. The turbulent air upstream
should change to a Laminar flow by the filter, Plenum and
diffuser into straight-line flow off the downstream face of the
filter. Filtered air should descend in a uni-directional flow over
the patient, creating a “Clean Zone”, rapidly removing
contamination generated within that zone and preventing
entry of contaminated air. Average air velocity below the
plenum, should be 0.24 meters per second The Modular OT
system shall be supplied together with Vertical Laminar Air
Flow ceiling system only. The laminar box size shall be
minimum 3000mm x 3000mm for all the OTs with air volume
delivery should not be less than 7000 m3/h at discharge
velocity ranging between 0.24m/s to 0.30m/s maximum.
Design parameters:
 Average air velocity below the plenum, be 0.24 meters per second
 The laminar airflow ceiling shall have Filters of H14 grade, EN 1822 standard.
 Double tight seat system to prevent leakages from sides of filter gaskets, filter frame and pressure frame.
 Mini-perforated plate/sheet; the vertical flow should achieve homogeneous flow.
 The vertical flow should ensure a sterile area of stable air hygiene over the operating table.
 Laminar airflow system shall comply with internationally accepted standards & meet with ISO Class 5 requirements.
The air management system will be designed to achieved the following Parameters
 Bacteriological class =B (10 CFU/m3)*
 Particle decontamination kinetics CP =5 min
 Biological decontamination kinetics CB = 5min
 ISO 14644/1 classification = ISO 5
Certificate of country of origin and manufacturers test certificates to be submitted after installation
Automatic sealing Sliding Doors
 All doors & door frames shall be made of stainless steel Material-Nr. 1.4301, SS 304 grade only.
 Thickness of SS sheet used for door frame & door panel surfaces shall not be 1.5mm. There shall not
be any visible screws or similar other uneven surfaces on the door pane
 All doors should have sturdy SS door handles on both sides. A lock shall be provided on each door.
 All doors shall have vision panels (viewing window) at least 300mm x 300mm.
 Automatic doors shall have potential equalization (earthing) as per VDE 0107 or equivalent
guaranteed by a sliding contact. Its automation unit shall be short-circuit proof and shall have an
integrated power supply unit 200-240V, 50-60 Hz, 24V~/2A and shall comply with ISO 9001 and CE
requirements.
 There are two sizes required 2100mm x 1500mm & 2100mm x 900mm, SS door frame grid is to be
designed accordingly. The door leaf should have sealing system in closed position.
 Vertically placed conductive push strip of minimum 1.0 mt height on both sides of the door for Auto
operation by elbow, foot or knee for entry / exit.
 Separate entry push buttons for OT staff, trolley.
 Dedicated push button on one side of door for cleaning purpose i.e. during cleaning area near OT
door, if required the said button is pressed which open the door will remain upon until pressed again.
 All the buttons & conductive push strip mounted on SS door frame and pre-wired internally from
factory.
Surgical Pendant
Certified as per Medical Device Directives (93/42/EEC) having
the CE mark Class IIb medical device with notified number
specified. Third party certification to EN 60601 Medical
Equipment Electrical Safety.
Compliant to BS EN 7396 NHS health technical memorandum
model engineering specification from the certifying agency
with copy of certificate of origin
The Surgical Pendant is capable of lateral and vertical
movement, using a double arm system.
The pendant have an electro-magnetic braking system.
The Pendant have visual colored brake indicators to indicate
which joint movement has been released. It should fully
conform to HTM 02-01 Standards.
The Surgical Pendant have a compact service console, 900 mm in length and containing the
following services, fully installed and tested:
 Front Mounted 38mm Multifunction Rack, providing accessory mounting and docking
solutions.
 5 No. Shelves with 1 drawer each mounted on the multifunction Rack and edged with
Medical Rail. All shelves are fully height adjustable.
 Rear Mounted Handle With Brake Controls.
 10 No. 230V 13A Socket Outlets
 2 No. Medical Oxygen Terminal Units
 2 No. Medical Air 4 Bar Terminal Units
 2 No. Surgical Air 7 Bar Terminal Units
 2 No. Medical Vacuum Terminal Units
 1 No. Medical carbon dioxide Terminal unit
 1 No. Twin RJ45 Data Outlet
 2 No. Single Gang Provisions for Data Services
 The pay load of the pendant 200 kg.
Anesthetic Pendant
Certified as per Medical Device Directives (93/42/EEC) having the CE mark
Class IIb medical device with notified number specified. Third party certification
to EN 60601 Medical Equipment Electrical Safety.
Compliant to BS EN 7396 NHS health technical memorandum model
engineering specification from the certifying agency with copy of certificate of
origin
The Anesthetic Pendant capable of lateral and vertical movement, using a
single arm system
The pendant have an electro-magnetic braking system. The Pendant Arms have
visual colored brake indicators to indicate which joint movement has been
released.
It fully conform to HTM 02-01 Standards. Certificate of country of origin and
manufacturers test certificates to be submitted after installation
Pendant should have a compact service console, 900 mm in length and containing the following
services, fully installed and tested:
 Front Mounted 38mm Multifunction Rack, providing accessory mounting and docking solutions.
 3 No. Shelves mounted on the Multifunction Rack and edged with Medical Rail. All shelves are fully
height adjustable.
 Rear Mounted Handle With Brake Controls.
 10 No. 230V 13A Socket Outlets
 2 No. Medical Oxygen Terminal Units
 2 No. Medical Nitrous Oxide Terminal Units
 2 No. Medical Air 4 Bar Terminal Units
 2 No. Surgical Air 7 Bar Terminal Units
 2 No. Medical Vacuum Terminal Units
 1 No. Medical AGSS Terminal Unit
 1 No. Medical Carbon Dioxide Terminal Units
 1 No. Twin RJ45 Data Outlet
 2 No. Single Gang Provisions for Data Services
 The pay load of the pendant be 175kg.
 The pendant have a wide range of maneuverability.
Modular Wall Panels
Surface clean room side made of be stainless steel 1.4301 (AISI 304), powder
coated, color white RAL 9010 or choice of color from shade card, with anti
microbiological coating to be provided
All the Operating Theatres be fully pre-fabricated and truly modular in design
having self-supporting, freestanding substructure.
The free standing substructure shall be made of GI of minimum 1.5mm sheet
thickness.
The substructure shall be firmly fixed onto the floor, slab/ceiling RCC with high
quality fasteners.
Substructure shall have additional horizontal support (mounting bracket) for
medical gases outlets, x-ray viewer, monitors etc. The wall substructure should be
calculated considering Floor to Slab height 3600mm
Wall cover panels made of Stainless steel (Material-Nr. 1.4301, SS 304 grade) of thickness not less than 1.0 mm. No other
material other than Stainless steel 304 grade shall be used for this purpose.
The SS wall panels shall be reinforced with 18mm non-flammable, high quality plaster board glued on the back of wall panels
to make a total thickness of 19 mm (1mm+18mm). Additional insulation to be provided, by high density mineral fiber mats
All the Wall panels, components of the structural material shall be totally prefabricated from the factory itself. All the wall
Panels shall be pre-powder coated and no painting job shall be carried out at site.
The pre-powder coating shall be maintained at a minimum deposit thickness of 60 microns and should have JIS Z 2801
certification from third party.
Wall and ceiling panels will be easily openable /closable for quick resumption of operations after repair/maintenance and for
future expansion and up-gradation.
Full height silicon rubber seal of Medical Grade shall be used to fill the gap between two wall panels to ensure a 100%
hermetically sealed vertical, flush with wall panels mounted joint. In all the corners of the OTs, especially fabricated, one
piece, angular SS wall panels shall be used.
The Modular OT wall system shall have certification for hygiene, noise protection, radiation protection & fire protection.
a) The fire resistance for single paneled wall system including substructure work should be class EI 30 (30 minutes
minimum) shall be in accordance with EN 13501-2, EI 1364-1
b) Metal structure work should be in accordance to DIN 18545.
c) CE compliance certification for all modular construction related components
d) The powder coating on wall panels should have third party (from reputed Lab) certification on compliance according to
JIS Z 2801 standard.
Certificate of country of origin and manufacturers test certificates to be submitted after installation
Modular False Ceiling
Clamping ceiling, cassette ceiling, galv. sheet steel 1.0 mm, non-perforated White wet-coated surface coffered ceiling
grid 600 x 600 mm or 1200 x 600 mm including substructure
Coating of the Ceiling Panel shall be not less than 40 micron with 180°C stove enameling and the color RAL 9010, Off-
white or powder coated.
The ceiling panels shall be secured by means of clip system and punched-in-knobs shall keep the panels in place and
shall ensure an exact ceiling level.
The panels are openable for future repair / maintenance & up-gradation. Certificate of country of origin and
manufacturers test certificates to be submitted after installation
X-ray view screen -
 X-Ray viewing screen of size 1050x430mm
 Four shutters for non-dazzling diagnostic use with flicker-
free HF light and variable control range of luminous
intensity,
 Control range approx. 90%,
 Flat film holders of silver anodized aluminum profile with
masked grip on all 4 sides of the viewing area.
1. Writing cum List Board
 Flush mounted white laminate board, opened to create a
wall mounted writing surface within the operating room.
The white board be constructed from white laminate board.
Clean-room luminaries with frame
Clean Room Luminaries, IP 65, recessed type to be provided in
OTs for general illumination.
6-8 nos. of IP-65 grade T16-lights, with dimming (intensity)
control, each light
1000 Lux illumination above 1 MTR floor level around the OT
table.
The light fixture will be hermetically sealed from top side
(ceiling side) have bottom opening for repair & maintenance.
Magnetic locking with the frame with no screws visible from
the bottom.
Certificate of country of origin and manufacturers test
certificates to be submitted after installation
1. LED Operating Theatre Light
The Operating Theatre Light will comprise of a
double structure with 2 lamp heads (main and
satellite.)
The lamp heads have multiple LED light sources
including a combination of red and white LEDs to
optimize colour rendition
The light have a Comfort Halo, to reduce eye strain for surgeons by creating a more gradual change in contrast between
the illuminated area and areas under general lighting.
Each lamp head allows for a wireless link to a wall mounted remote control to repeat all controls and indicators including:
 Lamp head On/Off Control
 Intensity
 Colour adjustment
 Field Size
The Operating Theatre Light meet the following technical parameters:
 Light Intensity – 160,000 Lux (Main) & 160,000 Lux (Satellite)
 Light Field Diameter (d10) – 200-420mm (Adjustable)
 Light Field Diameter (d50) – 120-250mm (Adjustable)
 Beam Uniformity (d50/d10 Ratio) – 0.6
 Comfort Halo – 2,000mm
 Lamp Head Nominal Power Consumption – 48W
 Radiant Energy mW/m².Lux - <3.31
 IP Rating of Light Engine – 54
 LED Life - >60,000 Hours
 Color Rendition Index:
o Ra – 95
o R1 – 99
o R2 – 97
o R3 – 93
o R4 – 93
o R5 – 98
o R6 – 96
o R7 – 94
o R8 – 92
o R9 – 95
 Red Balance Control to provide colour temperature of – 3100° K, 3400° K, 3700° K, 4100° K and 4600° K
 Removable, Sterile Handle
 Anti-Microbial Coating
 Number of LED Light Sources: 90 (Main) + 39 (sat)
Certificate of country of origin and manufacturers test certificates to be submitted after installation
HD Camera for OT Light
Integrated camera to be fully enclosed within the lamp head and behind the OT lamp protective front lens in order to
provide a permanent, robust and secure solution with reliable connectivity.
Direct Digital technology transmit a 1080i HDSDI signal directly from the camera, without processing or scaling, loss of
resolution or image detail.
Zoom controls provided on the lamp head.
Option for full camera control via a secure wireless remote control including control of:
 Zoom control
 Auto/Manual Focus
 Auto/Manual Iris
 White Balance Control
 Freeze Image
 Black and White / Colour Selection
 Digital Zoom Enable/Disable Selection
HD Camera System comply with the following technical parameters :
 Effective picture elements - Approx 2,000,000 pixels
 Video Signal - HDSDI: 1080i/59.94
 Lens - 10x zoom F1.8 to F2.1)
F=5.1 mm (WIDE) to 51 mm (TELE)
Zoom movement speed
Optical WIDE/Optical TELE 1.0 sec
Optical WIDE/Digital 4x TELE 1.5 sec
Digital WIDE/Digital 4x TELE 0.5 sec
Focus Movement °° to Near 0.1 sec
 Digital zoom - 12x (120x with optical zoom)
 Angle of view (H) - 50 degree (WIDE end) to 5.4 degree (TELE end)
 Min. object distance - 10 mm (WIDE end), 800 mm (TELE end)
 Min. illumination (Typical) - 12 lux (F1.8) with 50 IRE
1.0 lux ICR On (F1.8) with 50 IRE
 S/N ratio - 50 dB or more
 Electronic shutter speed - 1/2 to 1/10000 sec. (21 steps)
 White balance - AUTO, WB/Indoor/Outdoor/One Push WB/Manual WB
 Gain - Auto/Manual (-3 to +18 dB, 8 steps)
 AE control - Full Auto/Shutter Priority/Iris Priority/Manual/Bright/Spot AE
 Exposure compensation - ± 10.5 dB (15 steps in a unit of 1.5 dB)
 Aperture control - 16 steps
 Picture effect - Black & white, still image (frozen)
 Focus - Full Manual / Auto (Normal AF/ Interval AF/ Zoom Trigger AF)
 Camera Control interface - External communications via Medical Secure i2i wireless interface.
 Storage temperature/Humidity - -20 to 60°C (-4 to 140°F)/20 to 95%
 Operating temperature/Humidity - 0 to 45°C (32 to 113°F)/20 to 80%
 Power requirements/Power consumption - 6 to 12 V DC/4.8 W. Powered from OT light medical safety power supply. Fully powered during
emergency battery operation
HD Monitor
High Definition with dimension of 22”. Monitor medically approved with easy controls
via OSD Jog wheel interface
Edge to edge non-reflecting glass surface making it hygienic and easy to clean.
The monitor conform to the following parameters :
 Screen Design - True Flat design with edge
to edge wipe clean protection glass with AG coating
 User Controls - Jog wheel control and On screen
GUI Size - 21.5” / 54.6 cm
 Panel backlight - LED
 Aspect ratio - 16:9
 Active area (H × V) - 476.5 × 268.11 mm
 Resolution - 1920 × 1080
 Pixel pitch - 0.248 × 0.248
 Display colours - 16.7 M
 Luminance/Brightness - 300 cd/m2 typ.
 Contrast ratio - 5000:1
 Viewing angle (H × V) - 178° / 178°
 Response time typ. - 16 ms
 Video Input Ports - HD-SDI (3G), DVI
 Power consumption - ~30 W
 Dimensions (W × H × D) - 537.4 × 384.4 × 175.0 mm
 Temperature operating - +10 °C to +40 °C
 Humidity operating - 30 to 75 % RH
 Power supply - 24 VDC
 Mounting - VESA 100
 Regulatory Compliance - EN 60601-1 3rd; UL60601-1
3rd, RoHS
Certificate of country of origin and manufacturers test
certificates to be submitted after installation
Storage Unit:
 Storage cabinet of dimension 2100 x 900 x 600 (HxWxD) mm
 The storage cabinet shall be made of SS specification, same as used for wall panel,
 The door panels of the cabinet shall be in Stainless steel & partly in tempered glass.
 The storage Cabinet should have 4 trays. Certificate of country of origin and manufacturers test
certificates to be submitted after installation
Scrub Station:
 Two bay scrub station shall be made of stainless steel Material-Nr. 1.4301, SS 304 grade
with minimum 1.25mm thickness.
 Each sink of the scrub station have two soap dispensers and a tap operated with an
independent optical sensor with timer mode. The tap have an automatic mixer for hot &
cold water through a temperature regulator.
Pass Through Box
 Pass Through box of dimension 600mm (width) x 600 mm (Height) x 600mm (Depth).
 Made of SS 1.4301 (304 grades), thickness of the sheet to be used is 1.25 mm.
 The door panels of Stainless steel and partly in glass.
 Both doors electro-mechanically interlocked so that only one side door could be
opened at a time.
Certificate of country of origin and manufacturers test certificates to be submitted after
installation
HEPA Filter Air Outlets
 H13 grade, according to DIN EN 1822 standard complying with DIN 1946-4 standard, to be provided.
 Each Air filter capable to deliver 550m³/h air volume, pressure drop 130Pa
 Filter Frame made of extruded aluminum & factory testing for Leakage
 Filters are fitted with a lip seal into an installation sub frame with two or four fixing points.
 Equipped with a sealing integrity test facility, internal measuring tube, and pressure measurement point for monitoring
the operating differential pressure. Suspension and pressure measurement points either at the side or at the top.
 Casing made of sheet steel, powder-coated RAL 9010, pure white
 diffusers made of sheet steel, powder-coated RAL 9010
 Air-filter Outlet size:
 Nominal size: 625mm
 Connection diameter: 248mm
 Height of the casing: 384mm
 Certificate of country of origin and manufacturers test certificates to be submitted after installation
Description Plain Plates Survival Time Coating Killing Time
Staphylococcus Aureus Type 80/8 24Hrs 1Hr
Escherichia Coli NCTC 10418 24Hrs 1-2Hrs
Pseudomonas Aeruginosa 24Hrs 4-5Hrs
Beta Hemolytic Streptococcus 5-24Hrs 3Hrs
Salmonella Typimurium 24Hrs 4-5Hrs
Candida Albicans (Fungus) 24Hrs 2-3Hrs
•Antibacterial wall paint
Following Killing Time for most commonly found microbes in Operation Theater

More Related Content

Similar to 11641225.ppt

Esco Cytotoxic Safety Cabinet
Esco Cytotoxic Safety CabinetEsco Cytotoxic Safety Cabinet
Esco Cytotoxic Safety CabinetEsco Group
 
Esco Pharma Laminar Flow Straddle Units, Single and Double
Esco Pharma Laminar Flow Straddle Units, Single and DoubleEsco Pharma Laminar Flow Straddle Units, Single and Double
Esco Pharma Laminar Flow Straddle Units, Single and DoubleEsco Group
 
OKO-22M-UT Multi-Channel UT Flaw Detector
OKO-22M-UT Multi-Channel UT Flaw DetectorOKO-22M-UT Multi-Channel UT Flaw Detector
OKO-22M-UT Multi-Channel UT Flaw DetectorSvitlana Priannikova
 
Life Science Applications and Products - Magnetrol
Life Science Applications and Products - MagnetrolLife Science Applications and Products - Magnetrol
Life Science Applications and Products - MagnetrolMiller Energy, Inc.
 
Stability Test Chamber
Stability Test ChamberStability Test Chamber
Stability Test Chamberacmasindia
 
Esco evidence drying cabinet
Esco evidence drying cabinetEsco evidence drying cabinet
Esco evidence drying cabinetEsco Group
 
Horizontal Autoclave (Cylindrical) by ACMAS Technologies Pvt Ltd.
Horizontal Autoclave (Cylindrical) by ACMAS Technologies Pvt Ltd.Horizontal Autoclave (Cylindrical) by ACMAS Technologies Pvt Ltd.
Horizontal Autoclave (Cylindrical) by ACMAS Technologies Pvt Ltd.Acmas Technologies Pvt. Ltd.
 
Module-6-Design-of-Clean-Agent.pdf
Module-6-Design-of-Clean-Agent.pdfModule-6-Design-of-Clean-Agent.pdf
Module-6-Design-of-Clean-Agent.pdfMaryHazelSartoV
 
Ot infection control rkch
Ot infection control rkchOt infection control rkch
Ot infection control rkchsabahjak
 
Turbimax cus71 d endress+hauser datasheet-ultrasonic interface sensor
Turbimax cus71 d endress+hauser datasheet-ultrasonic interface sensorTurbimax cus71 d endress+hauser datasheet-ultrasonic interface sensor
Turbimax cus71 d endress+hauser datasheet-ultrasonic interface sensorENVIMART
 
Datasheet t8730
Datasheet t8730Datasheet t8730
Datasheet t8730ForTest12
 
Technotech Airflow Systems, Nagpur, HVAC & Clean Room Solutions
Technotech Airflow Systems, Nagpur, HVAC & Clean Room SolutionsTechnotech Airflow Systems, Nagpur, HVAC & Clean Room Solutions
Technotech Airflow Systems, Nagpur, HVAC & Clean Room SolutionsIndiaMART InterMESH Limited
 
aeolus critical care ventilator Compressor
aeolus critical care ventilator Compressoraeolus critical care ventilator Compressor
aeolus critical care ventilator CompressorSympaweb
 
Series One Safety Transmitter, Pressure and Temperature Switch
Series One Safety Transmitter, Pressure and Temperature SwitchSeries One Safety Transmitter, Pressure and Temperature Switch
Series One Safety Transmitter, Pressure and Temperature SwitchIves Equipment
 
Safety Transmitters for Temperature and Pressure
Safety Transmitters for Temperature and PressureSafety Transmitters for Temperature and Pressure
Safety Transmitters for Temperature and PressureMiller Energy, Inc.
 

Similar to 11641225.ppt (20)

Esco Cytotoxic Safety Cabinet
Esco Cytotoxic Safety CabinetEsco Cytotoxic Safety Cabinet
Esco Cytotoxic Safety Cabinet
 
Esco Pharma Laminar Flow Straddle Units, Single and Double
Esco Pharma Laminar Flow Straddle Units, Single and DoubleEsco Pharma Laminar Flow Straddle Units, Single and Double
Esco Pharma Laminar Flow Straddle Units, Single and Double
 
OKO-22M-UT Multi-Channel UT Flaw Detector
OKO-22M-UT Multi-Channel UT Flaw DetectorOKO-22M-UT Multi-Channel UT Flaw Detector
OKO-22M-UT Multi-Channel UT Flaw Detector
 
Life Science Applications and Products - Magnetrol
Life Science Applications and Products - MagnetrolLife Science Applications and Products - Magnetrol
Life Science Applications and Products - Magnetrol
 
Stability Test Chamber
Stability Test ChamberStability Test Chamber
Stability Test Chamber
 
Stability test chambers
Stability test chambersStability test chambers
Stability test chambers
 
Esco evidence drying cabinet
Esco evidence drying cabinetEsco evidence drying cabinet
Esco evidence drying cabinet
 
Horizontal Autoclave (Cylindrical) by ACMAS Technologies Pvt Ltd.
Horizontal Autoclave (Cylindrical) by ACMAS Technologies Pvt Ltd.Horizontal Autoclave (Cylindrical) by ACMAS Technologies Pvt Ltd.
Horizontal Autoclave (Cylindrical) by ACMAS Technologies Pvt Ltd.
 
ADKLIN CATALOG
ADKLIN CATALOGADKLIN CATALOG
ADKLIN CATALOG
 
Module-6-Design-of-Clean-Agent.pdf
Module-6-Design-of-Clean-Agent.pdfModule-6-Design-of-Clean-Agent.pdf
Module-6-Design-of-Clean-Agent.pdf
 
Ot infection control rkch
Ot infection control rkchOt infection control rkch
Ot infection control rkch
 
Turbimax cus71 d endress+hauser datasheet-ultrasonic interface sensor
Turbimax cus71 d endress+hauser datasheet-ultrasonic interface sensorTurbimax cus71 d endress+hauser datasheet-ultrasonic interface sensor
Turbimax cus71 d endress+hauser datasheet-ultrasonic interface sensor
 
Datasheet t8730
Datasheet t8730Datasheet t8730
Datasheet t8730
 
Vacuum Oven - Laboratory or Process Scale
Vacuum Oven - Laboratory or Process ScaleVacuum Oven - Laboratory or Process Scale
Vacuum Oven - Laboratory or Process Scale
 
Mwhe manual
Mwhe manualMwhe manual
Mwhe manual
 
Technotech Airflow Systems, Nagpur, HVAC & Clean Room Solutions
Technotech Airflow Systems, Nagpur, HVAC & Clean Room SolutionsTechnotech Airflow Systems, Nagpur, HVAC & Clean Room Solutions
Technotech Airflow Systems, Nagpur, HVAC & Clean Room Solutions
 
Fillunger All Product Booklet 2014
Fillunger All Product Booklet 2014Fillunger All Product Booklet 2014
Fillunger All Product Booklet 2014
 
aeolus critical care ventilator Compressor
aeolus critical care ventilator Compressoraeolus critical care ventilator Compressor
aeolus critical care ventilator Compressor
 
Series One Safety Transmitter, Pressure and Temperature Switch
Series One Safety Transmitter, Pressure and Temperature SwitchSeries One Safety Transmitter, Pressure and Temperature Switch
Series One Safety Transmitter, Pressure and Temperature Switch
 
Safety Transmitters for Temperature and Pressure
Safety Transmitters for Temperature and PressureSafety Transmitters for Temperature and Pressure
Safety Transmitters for Temperature and Pressure
 

More from mananshroff2

Shivam Sharma PPT GxtbbcfgbbcvOACON.pptx
Shivam Sharma PPT GxtbbcfgbbcvOACON.pptxShivam Sharma PPT GxtbbcfgbbcvOACON.pptx
Shivam Sharma PPT GxtbbcfgbbcvOACON.pptxmananshroff2
 
7) EXAMINATION OF THE HIP PGLC24 BHUJ by Dr.Vijay Sata Sir.pptx
7) EXAMINATION OF THE HIP PGLC24 BHUJ by Dr.Vijay Sata Sir.pptx7) EXAMINATION OF THE HIP PGLC24 BHUJ by Dr.Vijay Sata Sir.pptx
7) EXAMINATION OF THE HIP PGLC24 BHUJ by Dr.Vijay Sata Sir.pptxmananshroff2
 
Arterial Blood Gas Analysis.pptx
Arterial Blood Gas Analysis.pptxArterial Blood Gas Analysis.pptx
Arterial Blood Gas Analysis.pptxmananshroff2
 
Congenital disorders of respiratory system ppt.pptx
Congenital disorders of respiratory system ppt.pptxCongenital disorders of respiratory system ppt.pptx
Congenital disorders of respiratory system ppt.pptxmananshroff2
 
ANATOMY OF GASTROCSOLEUS COMPLEX AND TEAR OF TENDO.pptx
ANATOMY OF GASTROCSOLEUS COMPLEX AND TEAR OF TENDO.pptxANATOMY OF GASTROCSOLEUS COMPLEX AND TEAR OF TENDO.pptx
ANATOMY OF GASTROCSOLEUS COMPLEX AND TEAR OF TENDO.pptxmananshroff2
 
Manan Thesis presentation-3.pptx
Manan Thesis presentation-3.pptxManan Thesis presentation-3.pptx
Manan Thesis presentation-3.pptxmananshroff2
 

More from mananshroff2 (6)

Shivam Sharma PPT GxtbbcfgbbcvOACON.pptx
Shivam Sharma PPT GxtbbcfgbbcvOACON.pptxShivam Sharma PPT GxtbbcfgbbcvOACON.pptx
Shivam Sharma PPT GxtbbcfgbbcvOACON.pptx
 
7) EXAMINATION OF THE HIP PGLC24 BHUJ by Dr.Vijay Sata Sir.pptx
7) EXAMINATION OF THE HIP PGLC24 BHUJ by Dr.Vijay Sata Sir.pptx7) EXAMINATION OF THE HIP PGLC24 BHUJ by Dr.Vijay Sata Sir.pptx
7) EXAMINATION OF THE HIP PGLC24 BHUJ by Dr.Vijay Sata Sir.pptx
 
Arterial Blood Gas Analysis.pptx
Arterial Blood Gas Analysis.pptxArterial Blood Gas Analysis.pptx
Arterial Blood Gas Analysis.pptx
 
Congenital disorders of respiratory system ppt.pptx
Congenital disorders of respiratory system ppt.pptxCongenital disorders of respiratory system ppt.pptx
Congenital disorders of respiratory system ppt.pptx
 
ANATOMY OF GASTROCSOLEUS COMPLEX AND TEAR OF TENDO.pptx
ANATOMY OF GASTROCSOLEUS COMPLEX AND TEAR OF TENDO.pptxANATOMY OF GASTROCSOLEUS COMPLEX AND TEAR OF TENDO.pptx
ANATOMY OF GASTROCSOLEUS COMPLEX AND TEAR OF TENDO.pptx
 
Manan Thesis presentation-3.pptx
Manan Thesis presentation-3.pptxManan Thesis presentation-3.pptx
Manan Thesis presentation-3.pptx
 

Recently uploaded

KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...
KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...
KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...M56BOOKSTORE PRODUCT/SERVICE
 
Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111Sapana Sha
 
“Oh GOSH! Reflecting on Hackteria's Collaborative Practices in a Global Do-It...
“Oh GOSH! Reflecting on Hackteria's Collaborative Practices in a Global Do-It...“Oh GOSH! Reflecting on Hackteria's Collaborative Practices in a Global Do-It...
“Oh GOSH! Reflecting on Hackteria's Collaborative Practices in a Global Do-It...Marc Dusseiller Dusjagr
 
SOCIAL AND HISTORICAL CONTEXT - LFTVD.pptx
SOCIAL AND HISTORICAL CONTEXT - LFTVD.pptxSOCIAL AND HISTORICAL CONTEXT - LFTVD.pptx
SOCIAL AND HISTORICAL CONTEXT - LFTVD.pptxiammrhaywood
 
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPTECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPTiammrhaywood
 
Organic Name Reactions for the students and aspirants of Chemistry12th.pptx
Organic Name Reactions  for the students and aspirants of Chemistry12th.pptxOrganic Name Reactions  for the students and aspirants of Chemistry12th.pptx
Organic Name Reactions for the students and aspirants of Chemistry12th.pptxVS Mahajan Coaching Centre
 
Kisan Call Centre - To harness potential of ICT in Agriculture by answer farm...
Kisan Call Centre - To harness potential of ICT in Agriculture by answer farm...Kisan Call Centre - To harness potential of ICT in Agriculture by answer farm...
Kisan Call Centre - To harness potential of ICT in Agriculture by answer farm...Krashi Coaching
 
Enzyme, Pharmaceutical Aids, Miscellaneous Last Part of Chapter no 5th.pdf
Enzyme, Pharmaceutical Aids, Miscellaneous Last Part of Chapter no 5th.pdfEnzyme, Pharmaceutical Aids, Miscellaneous Last Part of Chapter no 5th.pdf
Enzyme, Pharmaceutical Aids, Miscellaneous Last Part of Chapter no 5th.pdfSumit Tiwari
 
MENTAL STATUS EXAMINATION format.docx
MENTAL     STATUS EXAMINATION format.docxMENTAL     STATUS EXAMINATION format.docx
MENTAL STATUS EXAMINATION format.docxPoojaSen20
 
Introduction to ArtificiaI Intelligence in Higher Education
Introduction to ArtificiaI Intelligence in Higher EducationIntroduction to ArtificiaI Intelligence in Higher Education
Introduction to ArtificiaI Intelligence in Higher Educationpboyjonauth
 
CARE OF CHILD IN INCUBATOR..........pptx
CARE OF CHILD IN INCUBATOR..........pptxCARE OF CHILD IN INCUBATOR..........pptx
CARE OF CHILD IN INCUBATOR..........pptxGaneshChakor2
 
Class 11 Legal Studies Ch-1 Concept of State .pdf
Class 11 Legal Studies Ch-1 Concept of State .pdfClass 11 Legal Studies Ch-1 Concept of State .pdf
Class 11 Legal Studies Ch-1 Concept of State .pdfakmcokerachita
 
Hybridoma Technology ( Production , Purification , and Application )
Hybridoma Technology  ( Production , Purification , and Application  ) Hybridoma Technology  ( Production , Purification , and Application  )
Hybridoma Technology ( Production , Purification , and Application ) Sakshi Ghasle
 
How to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptxHow to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptxmanuelaromero2013
 
Introduction to AI in Higher Education_draft.pptx
Introduction to AI in Higher Education_draft.pptxIntroduction to AI in Higher Education_draft.pptx
Introduction to AI in Higher Education_draft.pptxpboyjonauth
 
Concept of Vouching. B.Com(Hons) /B.Compdf
Concept of Vouching. B.Com(Hons) /B.CompdfConcept of Vouching. B.Com(Hons) /B.Compdf
Concept of Vouching. B.Com(Hons) /B.CompdfUmakantAnnand
 
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptxPOINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptxSayali Powar
 
Incoming and Outgoing Shipments in 1 STEP Using Odoo 17
Incoming and Outgoing Shipments in 1 STEP Using Odoo 17Incoming and Outgoing Shipments in 1 STEP Using Odoo 17
Incoming and Outgoing Shipments in 1 STEP Using Odoo 17Celine George
 

Recently uploaded (20)

KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...
KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...
KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...
 
Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111
 
“Oh GOSH! Reflecting on Hackteria's Collaborative Practices in a Global Do-It...
“Oh GOSH! Reflecting on Hackteria's Collaborative Practices in a Global Do-It...“Oh GOSH! Reflecting on Hackteria's Collaborative Practices in a Global Do-It...
“Oh GOSH! Reflecting on Hackteria's Collaborative Practices in a Global Do-It...
 
SOCIAL AND HISTORICAL CONTEXT - LFTVD.pptx
SOCIAL AND HISTORICAL CONTEXT - LFTVD.pptxSOCIAL AND HISTORICAL CONTEXT - LFTVD.pptx
SOCIAL AND HISTORICAL CONTEXT - LFTVD.pptx
 
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPTECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
 
Organic Name Reactions for the students and aspirants of Chemistry12th.pptx
Organic Name Reactions  for the students and aspirants of Chemistry12th.pptxOrganic Name Reactions  for the students and aspirants of Chemistry12th.pptx
Organic Name Reactions for the students and aspirants of Chemistry12th.pptx
 
Kisan Call Centre - To harness potential of ICT in Agriculture by answer farm...
Kisan Call Centre - To harness potential of ICT in Agriculture by answer farm...Kisan Call Centre - To harness potential of ICT in Agriculture by answer farm...
Kisan Call Centre - To harness potential of ICT in Agriculture by answer farm...
 
9953330565 Low Rate Call Girls In Rohini Delhi NCR
9953330565 Low Rate Call Girls In Rohini  Delhi NCR9953330565 Low Rate Call Girls In Rohini  Delhi NCR
9953330565 Low Rate Call Girls In Rohini Delhi NCR
 
Enzyme, Pharmaceutical Aids, Miscellaneous Last Part of Chapter no 5th.pdf
Enzyme, Pharmaceutical Aids, Miscellaneous Last Part of Chapter no 5th.pdfEnzyme, Pharmaceutical Aids, Miscellaneous Last Part of Chapter no 5th.pdf
Enzyme, Pharmaceutical Aids, Miscellaneous Last Part of Chapter no 5th.pdf
 
Código Creativo y Arte de Software | Unidad 1
Código Creativo y Arte de Software | Unidad 1Código Creativo y Arte de Software | Unidad 1
Código Creativo y Arte de Software | Unidad 1
 
MENTAL STATUS EXAMINATION format.docx
MENTAL     STATUS EXAMINATION format.docxMENTAL     STATUS EXAMINATION format.docx
MENTAL STATUS EXAMINATION format.docx
 
Introduction to ArtificiaI Intelligence in Higher Education
Introduction to ArtificiaI Intelligence in Higher EducationIntroduction to ArtificiaI Intelligence in Higher Education
Introduction to ArtificiaI Intelligence in Higher Education
 
CARE OF CHILD IN INCUBATOR..........pptx
CARE OF CHILD IN INCUBATOR..........pptxCARE OF CHILD IN INCUBATOR..........pptx
CARE OF CHILD IN INCUBATOR..........pptx
 
Class 11 Legal Studies Ch-1 Concept of State .pdf
Class 11 Legal Studies Ch-1 Concept of State .pdfClass 11 Legal Studies Ch-1 Concept of State .pdf
Class 11 Legal Studies Ch-1 Concept of State .pdf
 
Hybridoma Technology ( Production , Purification , and Application )
Hybridoma Technology  ( Production , Purification , and Application  ) Hybridoma Technology  ( Production , Purification , and Application  )
Hybridoma Technology ( Production , Purification , and Application )
 
How to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptxHow to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptx
 
Introduction to AI in Higher Education_draft.pptx
Introduction to AI in Higher Education_draft.pptxIntroduction to AI in Higher Education_draft.pptx
Introduction to AI in Higher Education_draft.pptx
 
Concept of Vouching. B.Com(Hons) /B.Compdf
Concept of Vouching. B.Com(Hons) /B.CompdfConcept of Vouching. B.Com(Hons) /B.Compdf
Concept of Vouching. B.Com(Hons) /B.Compdf
 
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptxPOINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
 
Incoming and Outgoing Shipments in 1 STEP Using Odoo 17
Incoming and Outgoing Shipments in 1 STEP Using Odoo 17Incoming and Outgoing Shipments in 1 STEP Using Odoo 17
Incoming and Outgoing Shipments in 1 STEP Using Odoo 17
 

11641225.ppt

  • 1. MODULAR OT Operation theatre is that specialized facility of the hospital where life saving or life improving procedures are carried out on the human body by invasive methods under strict aseptic conditions in a controlled environment by specially trained personnel to promote healing and cure with maximum safety, comfort and economy. It is imperative that operation theatre (OT) is designed scientifically to ensure sterility, easy maintenance and effective utilization. A civil – mechanical –electrical – electronic – biomedical combination driven and co-ordinated by needs , preferences and safety of the medical surgical team forms the basis of planning , starting and maintaining an operation theatre.
  • 2.
  • 3. • VARIOUS COMPONENTS OF MODULAR AND SEMI MODULAR OT • Antistatic Flooring - ESD vinyl The flooring confirm to following standards • EN 1081/IEC 613404, EN 1815 & EN 12466.Solid vinyl tile (SVT)(2mm). • 2.00mm, total weight 3.0 g/m2 polyurethane reinforced ,scratch resistant, fire resistant, chemical resistant , slip resistant, anti-fungi & bacterial growth , dimensional stability ≤0.40%, static electrical charger < 2Kv , impact sound reduction approx. +4bd, electrical resistant.
  • 4. Operation theatre control panel , surgeon control panel All the controls within the theatre should be located on a control panel mounted recessed in the theatre wall. The panel will incorporate all the necessary controls for the correct operation and monitoring of equipment and services within the operating theatre. Each control panel shall contain: • Display & control for Temp & humidity. • Control of Venetian blinds in windows & doors. • Status Indication of up to 5 Medical Gases + 1 Vacuum. • On/Off and regulation of Intensity of illumination in OT. • Digital Display of Real Time / Elapsed time • Intercom with speaker & microphone. • Microprocessor controlled Liquid Crystal Text Backlit display with 4 lines of 20 characters each. • There should be five illuminated buttons for Test, acknowledge, scroll, text & Menu. • Audio-visual alarms. • Normal, Warning & Alarm LED indications. Certificate of country of origin and manufacturers test certificates to be submitted after installation
  • 5. Over Flow Port  Provided in theatre to prevent cross contamination of air from clean and dirty areas.  Over flow port will be strategically placed, enable differential room pressure to be maintained and ensure that when doors are opened between clean and dirty area.  Over flow port, made of Stainless Steel 1.4301 (SS 304 grade)  Have filter element, which should be openable & cleanable.  Volume to be exhausted be between 175m3/h to 200m3/h. Certificate of country of origin and manufacturers test certificates to be submitted after installation
  • 6. Laminar air flow One of the main objectives of any operating theatre system is to dilute the bacteria generated by the operating team and patient in the theatre and to create an Air flow pattern that carries contaminated air away from the operating table & entering surgical wounds. A Laminar Flow System should contain three basic elements – a blower, a high efficiency air filter and a Plenum with a diffuser. The turbulent air upstream should change to a Laminar flow by the filter, Plenum and diffuser into straight-line flow off the downstream face of the filter. Filtered air should descend in a uni-directional flow over the patient, creating a “Clean Zone”, rapidly removing contamination generated within that zone and preventing entry of contaminated air. Average air velocity below the plenum, should be 0.24 meters per second The Modular OT system shall be supplied together with Vertical Laminar Air Flow ceiling system only. The laminar box size shall be minimum 3000mm x 3000mm for all the OTs with air volume delivery should not be less than 7000 m3/h at discharge velocity ranging between 0.24m/s to 0.30m/s maximum.
  • 7. Design parameters:  Average air velocity below the plenum, be 0.24 meters per second  The laminar airflow ceiling shall have Filters of H14 grade, EN 1822 standard.  Double tight seat system to prevent leakages from sides of filter gaskets, filter frame and pressure frame.  Mini-perforated plate/sheet; the vertical flow should achieve homogeneous flow.  The vertical flow should ensure a sterile area of stable air hygiene over the operating table.  Laminar airflow system shall comply with internationally accepted standards & meet with ISO Class 5 requirements. The air management system will be designed to achieved the following Parameters  Bacteriological class =B (10 CFU/m3)*  Particle decontamination kinetics CP =5 min  Biological decontamination kinetics CB = 5min  ISO 14644/1 classification = ISO 5 Certificate of country of origin and manufacturers test certificates to be submitted after installation
  • 8. Automatic sealing Sliding Doors  All doors & door frames shall be made of stainless steel Material-Nr. 1.4301, SS 304 grade only.  Thickness of SS sheet used for door frame & door panel surfaces shall not be 1.5mm. There shall not be any visible screws or similar other uneven surfaces on the door pane  All doors should have sturdy SS door handles on both sides. A lock shall be provided on each door.  All doors shall have vision panels (viewing window) at least 300mm x 300mm.  Automatic doors shall have potential equalization (earthing) as per VDE 0107 or equivalent guaranteed by a sliding contact. Its automation unit shall be short-circuit proof and shall have an integrated power supply unit 200-240V, 50-60 Hz, 24V~/2A and shall comply with ISO 9001 and CE requirements.  There are two sizes required 2100mm x 1500mm & 2100mm x 900mm, SS door frame grid is to be designed accordingly. The door leaf should have sealing system in closed position.  Vertically placed conductive push strip of minimum 1.0 mt height on both sides of the door for Auto operation by elbow, foot or knee for entry / exit.  Separate entry push buttons for OT staff, trolley.  Dedicated push button on one side of door for cleaning purpose i.e. during cleaning area near OT door, if required the said button is pressed which open the door will remain upon until pressed again.  All the buttons & conductive push strip mounted on SS door frame and pre-wired internally from factory.
  • 9. Surgical Pendant Certified as per Medical Device Directives (93/42/EEC) having the CE mark Class IIb medical device with notified number specified. Third party certification to EN 60601 Medical Equipment Electrical Safety. Compliant to BS EN 7396 NHS health technical memorandum model engineering specification from the certifying agency with copy of certificate of origin The Surgical Pendant is capable of lateral and vertical movement, using a double arm system. The pendant have an electro-magnetic braking system. The Pendant have visual colored brake indicators to indicate which joint movement has been released. It should fully conform to HTM 02-01 Standards.
  • 10. The Surgical Pendant have a compact service console, 900 mm in length and containing the following services, fully installed and tested:  Front Mounted 38mm Multifunction Rack, providing accessory mounting and docking solutions.  5 No. Shelves with 1 drawer each mounted on the multifunction Rack and edged with Medical Rail. All shelves are fully height adjustable.  Rear Mounted Handle With Brake Controls.  10 No. 230V 13A Socket Outlets  2 No. Medical Oxygen Terminal Units  2 No. Medical Air 4 Bar Terminal Units  2 No. Surgical Air 7 Bar Terminal Units  2 No. Medical Vacuum Terminal Units  1 No. Medical carbon dioxide Terminal unit  1 No. Twin RJ45 Data Outlet  2 No. Single Gang Provisions for Data Services  The pay load of the pendant 200 kg.
  • 11. Anesthetic Pendant Certified as per Medical Device Directives (93/42/EEC) having the CE mark Class IIb medical device with notified number specified. Third party certification to EN 60601 Medical Equipment Electrical Safety. Compliant to BS EN 7396 NHS health technical memorandum model engineering specification from the certifying agency with copy of certificate of origin The Anesthetic Pendant capable of lateral and vertical movement, using a single arm system The pendant have an electro-magnetic braking system. The Pendant Arms have visual colored brake indicators to indicate which joint movement has been released. It fully conform to HTM 02-01 Standards. Certificate of country of origin and manufacturers test certificates to be submitted after installation
  • 12. Pendant should have a compact service console, 900 mm in length and containing the following services, fully installed and tested:  Front Mounted 38mm Multifunction Rack, providing accessory mounting and docking solutions.  3 No. Shelves mounted on the Multifunction Rack and edged with Medical Rail. All shelves are fully height adjustable.  Rear Mounted Handle With Brake Controls.  10 No. 230V 13A Socket Outlets  2 No. Medical Oxygen Terminal Units  2 No. Medical Nitrous Oxide Terminal Units  2 No. Medical Air 4 Bar Terminal Units  2 No. Surgical Air 7 Bar Terminal Units  2 No. Medical Vacuum Terminal Units  1 No. Medical AGSS Terminal Unit  1 No. Medical Carbon Dioxide Terminal Units  1 No. Twin RJ45 Data Outlet  2 No. Single Gang Provisions for Data Services  The pay load of the pendant be 175kg.  The pendant have a wide range of maneuverability.
  • 13. Modular Wall Panels Surface clean room side made of be stainless steel 1.4301 (AISI 304), powder coated, color white RAL 9010 or choice of color from shade card, with anti microbiological coating to be provided All the Operating Theatres be fully pre-fabricated and truly modular in design having self-supporting, freestanding substructure. The free standing substructure shall be made of GI of minimum 1.5mm sheet thickness. The substructure shall be firmly fixed onto the floor, slab/ceiling RCC with high quality fasteners. Substructure shall have additional horizontal support (mounting bracket) for medical gases outlets, x-ray viewer, monitors etc. The wall substructure should be calculated considering Floor to Slab height 3600mm Wall cover panels made of Stainless steel (Material-Nr. 1.4301, SS 304 grade) of thickness not less than 1.0 mm. No other material other than Stainless steel 304 grade shall be used for this purpose. The SS wall panels shall be reinforced with 18mm non-flammable, high quality plaster board glued on the back of wall panels to make a total thickness of 19 mm (1mm+18mm). Additional insulation to be provided, by high density mineral fiber mats
  • 14.
  • 15.
  • 16. All the Wall panels, components of the structural material shall be totally prefabricated from the factory itself. All the wall Panels shall be pre-powder coated and no painting job shall be carried out at site. The pre-powder coating shall be maintained at a minimum deposit thickness of 60 microns and should have JIS Z 2801 certification from third party. Wall and ceiling panels will be easily openable /closable for quick resumption of operations after repair/maintenance and for future expansion and up-gradation. Full height silicon rubber seal of Medical Grade shall be used to fill the gap between two wall panels to ensure a 100% hermetically sealed vertical, flush with wall panels mounted joint. In all the corners of the OTs, especially fabricated, one piece, angular SS wall panels shall be used. The Modular OT wall system shall have certification for hygiene, noise protection, radiation protection & fire protection. a) The fire resistance for single paneled wall system including substructure work should be class EI 30 (30 minutes minimum) shall be in accordance with EN 13501-2, EI 1364-1 b) Metal structure work should be in accordance to DIN 18545. c) CE compliance certification for all modular construction related components d) The powder coating on wall panels should have third party (from reputed Lab) certification on compliance according to JIS Z 2801 standard. Certificate of country of origin and manufacturers test certificates to be submitted after installation
  • 17. Modular False Ceiling Clamping ceiling, cassette ceiling, galv. sheet steel 1.0 mm, non-perforated White wet-coated surface coffered ceiling grid 600 x 600 mm or 1200 x 600 mm including substructure Coating of the Ceiling Panel shall be not less than 40 micron with 180°C stove enameling and the color RAL 9010, Off- white or powder coated. The ceiling panels shall be secured by means of clip system and punched-in-knobs shall keep the panels in place and shall ensure an exact ceiling level. The panels are openable for future repair / maintenance & up-gradation. Certificate of country of origin and manufacturers test certificates to be submitted after installation
  • 18. X-ray view screen -  X-Ray viewing screen of size 1050x430mm  Four shutters for non-dazzling diagnostic use with flicker- free HF light and variable control range of luminous intensity,  Control range approx. 90%,  Flat film holders of silver anodized aluminum profile with masked grip on all 4 sides of the viewing area.
  • 19. 1. Writing cum List Board  Flush mounted white laminate board, opened to create a wall mounted writing surface within the operating room. The white board be constructed from white laminate board.
  • 20. Clean-room luminaries with frame Clean Room Luminaries, IP 65, recessed type to be provided in OTs for general illumination. 6-8 nos. of IP-65 grade T16-lights, with dimming (intensity) control, each light 1000 Lux illumination above 1 MTR floor level around the OT table. The light fixture will be hermetically sealed from top side (ceiling side) have bottom opening for repair & maintenance. Magnetic locking with the frame with no screws visible from the bottom. Certificate of country of origin and manufacturers test certificates to be submitted after installation
  • 21. 1. LED Operating Theatre Light The Operating Theatre Light will comprise of a double structure with 2 lamp heads (main and satellite.) The lamp heads have multiple LED light sources including a combination of red and white LEDs to optimize colour rendition The light have a Comfort Halo, to reduce eye strain for surgeons by creating a more gradual change in contrast between the illuminated area and areas under general lighting. Each lamp head allows for a wireless link to a wall mounted remote control to repeat all controls and indicators including:  Lamp head On/Off Control  Intensity  Colour adjustment  Field Size
  • 22. The Operating Theatre Light meet the following technical parameters:  Light Intensity – 160,000 Lux (Main) & 160,000 Lux (Satellite)  Light Field Diameter (d10) – 200-420mm (Adjustable)  Light Field Diameter (d50) – 120-250mm (Adjustable)  Beam Uniformity (d50/d10 Ratio) – 0.6  Comfort Halo – 2,000mm  Lamp Head Nominal Power Consumption – 48W  Radiant Energy mW/m².Lux - <3.31  IP Rating of Light Engine – 54  LED Life - >60,000 Hours  Color Rendition Index: o Ra – 95 o R1 – 99 o R2 – 97 o R3 – 93 o R4 – 93 o R5 – 98 o R6 – 96 o R7 – 94 o R8 – 92 o R9 – 95  Red Balance Control to provide colour temperature of – 3100° K, 3400° K, 3700° K, 4100° K and 4600° K  Removable, Sterile Handle  Anti-Microbial Coating  Number of LED Light Sources: 90 (Main) + 39 (sat) Certificate of country of origin and manufacturers test certificates to be submitted after installation
  • 23. HD Camera for OT Light Integrated camera to be fully enclosed within the lamp head and behind the OT lamp protective front lens in order to provide a permanent, robust and secure solution with reliable connectivity. Direct Digital technology transmit a 1080i HDSDI signal directly from the camera, without processing or scaling, loss of resolution or image detail. Zoom controls provided on the lamp head. Option for full camera control via a secure wireless remote control including control of:  Zoom control  Auto/Manual Focus  Auto/Manual Iris  White Balance Control  Freeze Image  Black and White / Colour Selection  Digital Zoom Enable/Disable Selection
  • 24. HD Camera System comply with the following technical parameters :  Effective picture elements - Approx 2,000,000 pixels  Video Signal - HDSDI: 1080i/59.94  Lens - 10x zoom F1.8 to F2.1) F=5.1 mm (WIDE) to 51 mm (TELE) Zoom movement speed Optical WIDE/Optical TELE 1.0 sec Optical WIDE/Digital 4x TELE 1.5 sec Digital WIDE/Digital 4x TELE 0.5 sec Focus Movement °° to Near 0.1 sec  Digital zoom - 12x (120x with optical zoom)  Angle of view (H) - 50 degree (WIDE end) to 5.4 degree (TELE end)  Min. object distance - 10 mm (WIDE end), 800 mm (TELE end)  Min. illumination (Typical) - 12 lux (F1.8) with 50 IRE 1.0 lux ICR On (F1.8) with 50 IRE  S/N ratio - 50 dB or more  Electronic shutter speed - 1/2 to 1/10000 sec. (21 steps)  White balance - AUTO, WB/Indoor/Outdoor/One Push WB/Manual WB  Gain - Auto/Manual (-3 to +18 dB, 8 steps)  AE control - Full Auto/Shutter Priority/Iris Priority/Manual/Bright/Spot AE  Exposure compensation - ± 10.5 dB (15 steps in a unit of 1.5 dB)  Aperture control - 16 steps  Picture effect - Black & white, still image (frozen)  Focus - Full Manual / Auto (Normal AF/ Interval AF/ Zoom Trigger AF)  Camera Control interface - External communications via Medical Secure i2i wireless interface.  Storage temperature/Humidity - -20 to 60°C (-4 to 140°F)/20 to 95%  Operating temperature/Humidity - 0 to 45°C (32 to 113°F)/20 to 80%  Power requirements/Power consumption - 6 to 12 V DC/4.8 W. Powered from OT light medical safety power supply. Fully powered during emergency battery operation
  • 25. HD Monitor High Definition with dimension of 22”. Monitor medically approved with easy controls via OSD Jog wheel interface Edge to edge non-reflecting glass surface making it hygienic and easy to clean.
  • 26. The monitor conform to the following parameters :  Screen Design - True Flat design with edge to edge wipe clean protection glass with AG coating  User Controls - Jog wheel control and On screen GUI Size - 21.5” / 54.6 cm  Panel backlight - LED  Aspect ratio - 16:9  Active area (H × V) - 476.5 × 268.11 mm  Resolution - 1920 × 1080  Pixel pitch - 0.248 × 0.248  Display colours - 16.7 M  Luminance/Brightness - 300 cd/m2 typ.  Contrast ratio - 5000:1  Viewing angle (H × V) - 178° / 178°  Response time typ. - 16 ms  Video Input Ports - HD-SDI (3G), DVI  Power consumption - ~30 W  Dimensions (W × H × D) - 537.4 × 384.4 × 175.0 mm  Temperature operating - +10 °C to +40 °C  Humidity operating - 30 to 75 % RH  Power supply - 24 VDC  Mounting - VESA 100  Regulatory Compliance - EN 60601-1 3rd; UL60601-1 3rd, RoHS Certificate of country of origin and manufacturers test certificates to be submitted after installation
  • 27. Storage Unit:  Storage cabinet of dimension 2100 x 900 x 600 (HxWxD) mm  The storage cabinet shall be made of SS specification, same as used for wall panel,  The door panels of the cabinet shall be in Stainless steel & partly in tempered glass.  The storage Cabinet should have 4 trays. Certificate of country of origin and manufacturers test certificates to be submitted after installation
  • 28. Scrub Station:  Two bay scrub station shall be made of stainless steel Material-Nr. 1.4301, SS 304 grade with minimum 1.25mm thickness.  Each sink of the scrub station have two soap dispensers and a tap operated with an independent optical sensor with timer mode. The tap have an automatic mixer for hot & cold water through a temperature regulator.
  • 29. Pass Through Box  Pass Through box of dimension 600mm (width) x 600 mm (Height) x 600mm (Depth).  Made of SS 1.4301 (304 grades), thickness of the sheet to be used is 1.25 mm.  The door panels of Stainless steel and partly in glass.  Both doors electro-mechanically interlocked so that only one side door could be opened at a time. Certificate of country of origin and manufacturers test certificates to be submitted after installation
  • 30. HEPA Filter Air Outlets  H13 grade, according to DIN EN 1822 standard complying with DIN 1946-4 standard, to be provided.  Each Air filter capable to deliver 550m³/h air volume, pressure drop 130Pa  Filter Frame made of extruded aluminum & factory testing for Leakage  Filters are fitted with a lip seal into an installation sub frame with two or four fixing points.  Equipped with a sealing integrity test facility, internal measuring tube, and pressure measurement point for monitoring the operating differential pressure. Suspension and pressure measurement points either at the side or at the top.  Casing made of sheet steel, powder-coated RAL 9010, pure white  diffusers made of sheet steel, powder-coated RAL 9010  Air-filter Outlet size:  Nominal size: 625mm  Connection diameter: 248mm  Height of the casing: 384mm  Certificate of country of origin and manufacturers test certificates to be submitted after installation
  • 31. Description Plain Plates Survival Time Coating Killing Time Staphylococcus Aureus Type 80/8 24Hrs 1Hr Escherichia Coli NCTC 10418 24Hrs 1-2Hrs Pseudomonas Aeruginosa 24Hrs 4-5Hrs Beta Hemolytic Streptococcus 5-24Hrs 3Hrs Salmonella Typimurium 24Hrs 4-5Hrs Candida Albicans (Fungus) 24Hrs 2-3Hrs •Antibacterial wall paint Following Killing Time for most commonly found microbes in Operation Theater