© Siemens AG 2010

                Pressure Measurement
      Transmitters for basic requirements
      SITRANS P Z
      for gauge pressure

    ■ Overview                                                             ■ Design
                                                                             The main components of the pressure transmitter are:
                                                                             • Brass housing with silicon measuring cell and electronics
                                                                               plate

2                                                                            • Process connection
                                                                             • Electrical connection
                                                                             The silicon measuring cell has a thin-film strain gauge which is
                                                                             mounted on a ceramic diaphragm. The ceramic diaphragm can
                                                                             also be used for aggressive media.
                                                                             The process connection to DIN EN 837-1 is made of brass and
                                                                             has a male thread G½B or a female thread G1/8B.
                                                                             The electrical connection is made using a plug to DIN 43650
                                                                             with a M16 x 1.5 cable inlet.

                                                                           ■ Function
                                                                             The pressure transmitters of the SITRANS P Z for gauge pres-
                                                                             sure measure the gauge pressure of aggressive and non-ag-
      The SITRANS P Z pressure transmitter, (7MF1562-...) measures           gressive gases, liquids and vapors.
      the gauge pressure of aggressive and non-aggressive gases,
      liquids and vapors.                                                    The measuring cell is temperature-compensated.
                                                                             Mode of operation
    ■ Benefits
      •   High measuring accuracy
      •   Sturdy brass housing                                                                                         U
                                                                                                                     const.
      •   For aggressive and non-aggressive media
      •   For measuring the gauge pressure of liquids, gases and vapor                                                          U
                                                                               p                                                    I      I0, UB
      •   Temperature-compensated measuring cell
      •   Compact design

    ■ Application
      The SITRANS P Z pressure transmitter for gauge pressure                SITRANS P Z pressure transmitters (7MF1562-...), function diagram
      (7MF1562-...) is used above all in the following industrial areas:
                                                                             The thin-film measuring cell has a thin-film resistance bridge at
      • Power engineering
                                                                             which the operating pressure p is transmitted through a ceramic
      • Mechanical engineering                                               diaphragm.
      • Shipbuilding                                                         The measuring cell output voltage is fed to an amplifier and con-
      • Water supply etc.                                                    verted into an output current of 4 to 20 mA. The output current is
                                                                             linearly proportional to the input pressure.
      A concrete application example is the measurement of com-
      pressed air containing oil in compressors or compressor sta-
      tions.




          2/4      Siemens FI 01 · 2011
© Siemens AG 2010

                                                                                                       Pressure Measurement
                                                                                            Transmitters for basic requirements
                                                                                                                                            SITRANS P Z
                                                                                                                                      for gauge pressure

■ Technical specifications                                                       Design
                                                                                 Weight                                       ≈ 0.2 kg (≈ 0.44 lb)
  SITRANS P Z pressure transmitters for gauge pressure
                                                                                 Wetted parts materials
  Mode of operation
                                                                                 • Measuring cell                             Al2O3 – 96 %
  Measuring principle                    Thin-film strain gauge
  Input
                                                                                 • Process connection
                                                                                 • Gasket
                                                                                                                              Brass, mat. no. 2.0402
                                                                                                                              Viton
                                                                                                                                                                     2
  Measured variable                      Gauge pressure
                                                                                 Process connection                           Male thread G½B
  Measuring range                        0 ... 16 bar g (0 ... 232 psi g) or                                                  female thread G1/8B
                                         0 ... 25 bar g (0 ... 363 psi g)
                                                                                 Power supply
  Output
                                                                                 Terminal voltage on pressure trans-
  Current output signal                  4 ... 20 mA                             mitter
  Measuring accuracy                     as per EN 60770-1                       • For current output                         10 ... 36 V DC
  Error in measurement (at 25 °C         0.5 % of full-scale value – typical     Certificates and approvals
  (77 °F), including conformity error,
  hysteresis and repeatability)                                                  Classification according to                  For gases of fluid group 1 and
                                                                                 PED 97/23/EC                                 liquids of fluid 1; complies with
  Response time T99                      < 0.1 s                                                                              requirements of article 3, para-
                                                                                                                              graph 3 (sound engineering prac-
  Long-term drift                        0.3 % of full-scale value/year -                                                     tice)
                                         typical
  Influence of ambient temperature
  • Start of scale                       0.3 %/10 K of full-scale value -
                                         typical                               ■ Dimensional drawings
  • Measuring span                       0.3 %/10 K of full-scale value -
                                         typical
                                                                                                                   112 (4.4)
  Rated conditions                                                                                       20
                                                                                                        (0.8)
  Medium conditions




                                                                                                                 (diam 1.1)
  • Temperature of medium                -30 ... +120 °C (-22 ... +248 °F)



                                                                                                                    ∅27




                                                                                                                                               (1.97)
  degree of protection to EN 60529       IP65




                                                                                                                                                 50
  Ambient conditions
                                                                                                       G½B
                                                                                                G 8B
                                                                                                1




  • Ambient temperature                  -25 ... +85 °C (-13 ... +185 °F)                                       SW 27 M16x1,5
  • Storage temperature                  -50 ... +100 °C (-58 ... +212 °F)
                                                                                 SITRANS P Z pressure transmitters (7MF1562-...), dimensions in mm
                                                                                 (inch)

                                                                               ■ Schematics
                                                                                                                                             I0 Output current
                                                                                               1+                                            UB Power supply
                                                                                                                   I0                 UB     RL Load
                                                                                               2-
                                                                                      Signal                                  RL             Connections:
                                                                                                                                             1 (+UB)
                                                                                                                                             2 (-UB)




                                                                                 SITRANS P Z pressure transmitters (7MF1562-...), connection diagram



■ Selection and Ordering data                                                                                           Order No.                       Order code
  SITRANS P Z pressure transmitters for gauge pressure                                                           D) 7 M F 1 5 6 2 - 7 7 7 0 0                777
  2-wire system, characteristic rising
  Measured range                          Max. working pressure
  0 ... 16 bar g (0 ... 232 psi g)        32 bar g  (464 psi g)                                                                       3 CB
  0 ... 25 bar g (0 ... 363 psi g)        64 bar g  (928 psi g)                                                                       3 CD
  Other version for measuring range ≥ 1 bar g (≥ 14.5 psi g), add Order code and plain text:                                          9 AA                   H1Y
  Measuring range: ... to ... bar g (psi g)
  D) Subject to export regulations AL: N, ECCN: EAR99H.




                                                                                                                              Siemens FI 01 · 2011          2/5

More Related Content

What's hot

Testo - 6448 - Compressed air counter shaft probe
Testo - 6448 - Compressed air counter shaft probeTesto - 6448 - Compressed air counter shaft probe
Testo - 6448 - Compressed air counter shaft probeTesto Limited
 
GridPoint\’s Energy Management System Intelligent Controllers
GridPoint\’s Energy Management System Intelligent ControllersGridPoint\’s Energy Management System Intelligent Controllers
GridPoint\’s Energy Management System Intelligent ControllersMichele_Zambrano333
 
cảm biến áp suất -phan1
cảm biến áp suất -phan1cảm biến áp suất -phan1
cảm biến áp suất -phan1Bùi Thể
 
710 minisit gb
710 minisit gb710 minisit gb
710 minisit gbeng_vcruz
 
Kazakistan ing referasn albümü hg
Kazakistan ing referasn albümü hgKazakistan ing referasn albümü hg
Kazakistan ing referasn albümü hgguestb585ef
 

What's hot (7)

Testo - 6448 - Compressed air counter shaft probe
Testo - 6448 - Compressed air counter shaft probeTesto - 6448 - Compressed air counter shaft probe
Testo - 6448 - Compressed air counter shaft probe
 
Air cooled after cooler
Air cooled after coolerAir cooled after cooler
Air cooled after cooler
 
GridPoint\’s Energy Management System Intelligent Controllers
GridPoint\’s Energy Management System Intelligent ControllersGridPoint\’s Energy Management System Intelligent Controllers
GridPoint\’s Energy Management System Intelligent Controllers
 
cảm biến áp suất -phan1
cảm biến áp suất -phan1cảm biến áp suất -phan1
cảm biến áp suất -phan1
 
Calibrare sylvac
Calibrare sylvacCalibrare sylvac
Calibrare sylvac
 
710 minisit gb
710 minisit gb710 minisit gb
710 minisit gb
 
Kazakistan ing referasn albümü hg
Kazakistan ing referasn albümü hgKazakistan ing referasn albümü hg
Kazakistan ing referasn albümü hg
 

Similar to Cam bien-ap-suat-phan2

Cảm biến áp suất MPS
Cảm biến áp suất MPSCảm biến áp suất MPS
Cảm biến áp suất MPSBùi Thể
 
Cảm biến áp suất P250
Cảm biến áp suất P250Cảm biến áp suất P250
Cảm biến áp suất P250Bùi Thể
 
High pressure transducer
High pressure transducerHigh pressure transducer
High pressure transducerKAUSTUBH GOMASE
 
Fluid-Controls-DIN-Single-Ferrule-Fittings.pdf
Fluid-Controls-DIN-Single-Ferrule-Fittings.pdfFluid-Controls-DIN-Single-Ferrule-Fittings.pdf
Fluid-Controls-DIN-Single-Ferrule-Fittings.pdfFluidControls1
 
Indicating, recording &amp; controlling devices used in dairy plants principl...
Indicating, recording &amp; controlling devices used in dairy plants principl...Indicating, recording &amp; controlling devices used in dairy plants principl...
Indicating, recording &amp; controlling devices used in dairy plants principl...Dhruv Patel
 
Claw© "RTM" System
Claw© "RTM" SystemClaw© "RTM" System
Claw© "RTM" SystemSertecpet
 
160120119032 2141901
160120119032 2141901160120119032 2141901
160120119032 2141901Bhavesh Jain
 
D1 be29c1d01
D1 be29c1d01D1 be29c1d01
D1 be29c1d01malae
 
UNIT 1 FUNDAMENTALS OF MEASUREMENT
UNIT 1 FUNDAMENTALS  OF MEASUREMENTUNIT 1 FUNDAMENTALS  OF MEASUREMENT
UNIT 1 FUNDAMENTALS OF MEASUREMENTprthumar
 
PRESSURE INSTRUMENTATION
PRESSURE INSTRUMENTATIONPRESSURE INSTRUMENTATION
PRESSURE INSTRUMENTATIONsanket kulkarni
 
WQD2011 - INNOVATION - EMAL - Torque measuring device
WQD2011 - INNOVATION - EMAL - Torque measuring deviceWQD2011 - INNOVATION - EMAL - Torque measuring device
WQD2011 - INNOVATION - EMAL - Torque measuring deviceDubai Quality Group
 
Ipc nee 303 ppt even sem
Ipc nee 303 ppt even semIpc nee 303 ppt even sem
Ipc nee 303 ppt even semSatyendra Mohan
 
Field transmitters
Field transmittersField transmitters
Field transmittersPrasad Godse
 
Addmas Measurements, Ahmedabad, Field Instruments
Addmas Measurements, Ahmedabad, Field InstrumentsAddmas Measurements, Ahmedabad, Field Instruments
Addmas Measurements, Ahmedabad, Field InstrumentsIndiaMART InterMESH Limited
 

Similar to Cam bien-ap-suat-phan2 (20)

Cảm biến áp suất MPS
Cảm biến áp suất MPSCảm biến áp suất MPS
Cảm biến áp suất MPS
 
Cảm biến áp suất P250
Cảm biến áp suất P250Cảm biến áp suất P250
Cảm biến áp suất P250
 
Instrumentation
InstrumentationInstrumentation
Instrumentation
 
Module 3.pdf
Module 3.pdfModule 3.pdf
Module 3.pdf
 
High pressure transducer
High pressure transducerHigh pressure transducer
High pressure transducer
 
Fluid-Controls-DIN-Single-Ferrule-Fittings.pdf
Fluid-Controls-DIN-Single-Ferrule-Fittings.pdfFluid-Controls-DIN-Single-Ferrule-Fittings.pdf
Fluid-Controls-DIN-Single-Ferrule-Fittings.pdf
 
Indicating, recording &amp; controlling devices used in dairy plants principl...
Indicating, recording &amp; controlling devices used in dairy plants principl...Indicating, recording &amp; controlling devices used in dairy plants principl...
Indicating, recording &amp; controlling devices used in dairy plants principl...
 
Claw© "RTM" System
Claw© "RTM" SystemClaw© "RTM" System
Claw© "RTM" System
 
160120119032 2141901
160120119032 2141901160120119032 2141901
160120119032 2141901
 
D1 be29c1d01
D1 be29c1d01D1 be29c1d01
D1 be29c1d01
 
UNIT 1 FUNDAMENTALS OF MEASUREMENT
UNIT 1 FUNDAMENTALS  OF MEASUREMENTUNIT 1 FUNDAMENTALS  OF MEASUREMENT
UNIT 1 FUNDAMENTALS OF MEASUREMENT
 
PRESSURE INSTRUMENTATION
PRESSURE INSTRUMENTATIONPRESSURE INSTRUMENTATION
PRESSURE INSTRUMENTATION
 
WQD2011 - INNOVATION - EMAL - Torque measuring device
WQD2011 - INNOVATION - EMAL - Torque measuring deviceWQD2011 - INNOVATION - EMAL - Torque measuring device
WQD2011 - INNOVATION - EMAL - Torque measuring device
 
Ipc nee 303 ppt even sem
Ipc nee 303 ppt even semIpc nee 303 ppt even sem
Ipc nee 303 ppt even sem
 
Field transmitters
Field transmittersField transmitters
Field transmitters
 
Addmas Measurements, Ahmedabad, Field Instruments
Addmas Measurements, Ahmedabad, Field InstrumentsAddmas Measurements, Ahmedabad, Field Instruments
Addmas Measurements, Ahmedabad, Field Instruments
 
Pressure measurement
Pressure measurement Pressure measurement
Pressure measurement
 
Sprague goodman
Sprague goodmanSprague goodman
Sprague goodman
 
Mcim
McimMcim
Mcim
 
Strain gauge
Strain gaugeStrain gauge
Strain gauge
 

More from Bùi Thể

Plc-s7-1200-opc-to-pc-connection-guide
Plc-s7-1200-opc-to-pc-connection-guidePlc-s7-1200-opc-to-pc-connection-guide
Plc-s7-1200-opc-to-pc-connection-guideBùi Thể
 
Plc s7-300-special-communication1
Plc s7-300-special-communication1Plc s7-300-special-communication1
Plc s7-300-special-communication1Bùi Thể
 
Cảm biến mức LR400
Cảm biến mức LR400Cảm biến mức LR400
Cảm biến mức LR400Bùi Thể
 
PLC S7- 300 module data_manual_en-us_en-us
PLC S7- 300 module data_manual_en-us_en-usPLC S7- 300 module data_manual_en-us_en-us
PLC S7- 300 module data_manual_en-us_en-usBùi Thể
 
Phan mem plc s7 1200 opc simatic-net-e
Phan mem plc s7 1200 opc simatic-net-ePhan mem plc s7 1200 opc simatic-net-e
Phan mem plc s7 1200 opc simatic-net-eBùi Thể
 
Giao trinh-plc-s7-1200-easy book
Giao trinh-plc-s7-1200-easy bookGiao trinh-plc-s7-1200-easy book
Giao trinh-plc-s7-1200-easy bookBùi Thể
 
Tai lieu plc s7 200
Tai lieu plc s7 200Tai lieu plc s7 200
Tai lieu plc s7 200Bùi Thể
 
Tai lieu plc s7 1200
Tai lieu plc s7 1200Tai lieu plc s7 1200
Tai lieu plc s7 1200Bùi Thể
 
Tai lieu plc s7 300
Tai lieu plc s7 300Tai lieu plc s7 300
Tai lieu plc s7 300Bùi Thể
 
Tai lieu plc s7 300
Tai lieu plc s7 300Tai lieu plc s7 300
Tai lieu plc s7 300Bùi Thể
 

More from Bùi Thể (10)

Plc-s7-1200-opc-to-pc-connection-guide
Plc-s7-1200-opc-to-pc-connection-guidePlc-s7-1200-opc-to-pc-connection-guide
Plc-s7-1200-opc-to-pc-connection-guide
 
Plc s7-300-special-communication1
Plc s7-300-special-communication1Plc s7-300-special-communication1
Plc s7-300-special-communication1
 
Cảm biến mức LR400
Cảm biến mức LR400Cảm biến mức LR400
Cảm biến mức LR400
 
PLC S7- 300 module data_manual_en-us_en-us
PLC S7- 300 module data_manual_en-us_en-usPLC S7- 300 module data_manual_en-us_en-us
PLC S7- 300 module data_manual_en-us_en-us
 
Phan mem plc s7 1200 opc simatic-net-e
Phan mem plc s7 1200 opc simatic-net-ePhan mem plc s7 1200 opc simatic-net-e
Phan mem plc s7 1200 opc simatic-net-e
 
Giao trinh-plc-s7-1200-easy book
Giao trinh-plc-s7-1200-easy bookGiao trinh-plc-s7-1200-easy book
Giao trinh-plc-s7-1200-easy book
 
Tai lieu plc s7 200
Tai lieu plc s7 200Tai lieu plc s7 200
Tai lieu plc s7 200
 
Tai lieu plc s7 1200
Tai lieu plc s7 1200Tai lieu plc s7 1200
Tai lieu plc s7 1200
 
Tai lieu plc s7 300
Tai lieu plc s7 300Tai lieu plc s7 300
Tai lieu plc s7 300
 
Tai lieu plc s7 300
Tai lieu plc s7 300Tai lieu plc s7 300
Tai lieu plc s7 300
 

Cam bien-ap-suat-phan2

  • 1. © Siemens AG 2010 Pressure Measurement Transmitters for basic requirements SITRANS P Z for gauge pressure ■ Overview ■ Design The main components of the pressure transmitter are: • Brass housing with silicon measuring cell and electronics plate 2 • Process connection • Electrical connection The silicon measuring cell has a thin-film strain gauge which is mounted on a ceramic diaphragm. The ceramic diaphragm can also be used for aggressive media. The process connection to DIN EN 837-1 is made of brass and has a male thread G½B or a female thread G1/8B. The electrical connection is made using a plug to DIN 43650 with a M16 x 1.5 cable inlet. ■ Function The pressure transmitters of the SITRANS P Z for gauge pres- sure measure the gauge pressure of aggressive and non-ag- The SITRANS P Z pressure transmitter, (7MF1562-...) measures gressive gases, liquids and vapors. the gauge pressure of aggressive and non-aggressive gases, liquids and vapors. The measuring cell is temperature-compensated. Mode of operation ■ Benefits • High measuring accuracy • Sturdy brass housing U const. • For aggressive and non-aggressive media • For measuring the gauge pressure of liquids, gases and vapor U p I I0, UB • Temperature-compensated measuring cell • Compact design ■ Application The SITRANS P Z pressure transmitter for gauge pressure SITRANS P Z pressure transmitters (7MF1562-...), function diagram (7MF1562-...) is used above all in the following industrial areas: The thin-film measuring cell has a thin-film resistance bridge at • Power engineering which the operating pressure p is transmitted through a ceramic • Mechanical engineering diaphragm. • Shipbuilding The measuring cell output voltage is fed to an amplifier and con- • Water supply etc. verted into an output current of 4 to 20 mA. The output current is linearly proportional to the input pressure. A concrete application example is the measurement of com- pressed air containing oil in compressors or compressor sta- tions. 2/4 Siemens FI 01 · 2011
  • 2. © Siemens AG 2010 Pressure Measurement Transmitters for basic requirements SITRANS P Z for gauge pressure ■ Technical specifications Design Weight ≈ 0.2 kg (≈ 0.44 lb) SITRANS P Z pressure transmitters for gauge pressure Wetted parts materials Mode of operation • Measuring cell Al2O3 – 96 % Measuring principle Thin-film strain gauge Input • Process connection • Gasket Brass, mat. no. 2.0402 Viton 2 Measured variable Gauge pressure Process connection Male thread G½B Measuring range 0 ... 16 bar g (0 ... 232 psi g) or female thread G1/8B 0 ... 25 bar g (0 ... 363 psi g) Power supply Output Terminal voltage on pressure trans- Current output signal 4 ... 20 mA mitter Measuring accuracy as per EN 60770-1 • For current output 10 ... 36 V DC Error in measurement (at 25 °C 0.5 % of full-scale value – typical Certificates and approvals (77 °F), including conformity error, hysteresis and repeatability) Classification according to For gases of fluid group 1 and PED 97/23/EC liquids of fluid 1; complies with Response time T99 < 0.1 s requirements of article 3, para- graph 3 (sound engineering prac- Long-term drift 0.3 % of full-scale value/year - tice) typical Influence of ambient temperature • Start of scale 0.3 %/10 K of full-scale value - typical ■ Dimensional drawings • Measuring span 0.3 %/10 K of full-scale value - typical 112 (4.4) Rated conditions 20 (0.8) Medium conditions (diam 1.1) • Temperature of medium -30 ... +120 °C (-22 ... +248 °F) ∅27 (1.97) degree of protection to EN 60529 IP65 50 Ambient conditions G½B G 8B 1 • Ambient temperature -25 ... +85 °C (-13 ... +185 °F) SW 27 M16x1,5 • Storage temperature -50 ... +100 °C (-58 ... +212 °F) SITRANS P Z pressure transmitters (7MF1562-...), dimensions in mm (inch) ■ Schematics I0 Output current 1+ UB Power supply I0 UB RL Load 2- Signal RL Connections: 1 (+UB) 2 (-UB) SITRANS P Z pressure transmitters (7MF1562-...), connection diagram ■ Selection and Ordering data Order No. Order code SITRANS P Z pressure transmitters for gauge pressure D) 7 M F 1 5 6 2 - 7 7 7 0 0 777 2-wire system, characteristic rising Measured range Max. working pressure 0 ... 16 bar g (0 ... 232 psi g) 32 bar g (464 psi g) 3 CB 0 ... 25 bar g (0 ... 363 psi g) 64 bar g (928 psi g) 3 CD Other version for measuring range ≥ 1 bar g (≥ 14.5 psi g), add Order code and plain text: 9 AA H1Y Measuring range: ... to ... bar g (psi g) D) Subject to export regulations AL: N, ECCN: EAR99H. Siemens FI 01 · 2011 2/5