An Ethernet Cable Discharge Event (CDE)
Test and Measurement System
Wei Huang, Jerry Tichenor
ESDEMC Technology LLC
Rolla, MO, USA
whuang@esdemc.com
David Pommerenke, Viswa Pilla, Pratik
Maheshwari, Giorgi Maghlakelidze
Electromagnetic Compatibility Laboratory, Missouri S&T
Rolla, MO, USA
davidjp@mst.edu
Abstract— A Cable Discharge Event (CDE) is an electrostatic
discharge between a cable and a connector. CDEs occur on
unshielded Ethernet based communication interfaces and inject
currents into the pins directly [1-3]. The charging processes are in
general understood; however, the discharge processes are
complicated due to the number of pins involved and their
connections to a system. Based on an understanding of the factors
which determine the severity of a CDE, this article describes how
to setup a variety of repeatable CDE tests and how to analyze the
measurement results.
Keywords— Cable Discharge Event (CDE) Test; Cable ESD;
I. INTRODUCTION
Both occurrence rate and severity of a CDE needs to be
considered when determining the importance of dedicated CDE
tests to ensure a reliable system. The occurrence rate of a CDE
depends on the type of connector used and the environment the
system is used. While a USB connector on a laptop will receive
many more ESD events than a LAN connector, the LAN
connector still poses a larger risk to the system as it is usually
not shielded and often used in applications that require high
reliability such as back bone internet routers. In contrast to a
USB connector, a LAN connector can have a spark from the
connector to a pin during a CDE. In the case of USB connectors
the connector shells will mate first. Provided that the shells are
connected to the shield and to the system ground, most of the
discharge current will flow on the connector shells.
For the LAN CDE case a good understanding of the
dominating processes provides a mean for developing and
validating models. These models will allow computer
simulation, and laboratory test setup formulation for
reproducing real CDEs. This is crucial for IC and system level
engineers to study and optimize the immunity of Ethernet based
communications interface designs.
It is well known that triboelectric charging is the culprit that
generates the charge on a cable [1],[2]. This fact is especially
important in Ethernet communication systems due to the long
lengths of UPT cable that must be pulled through conduit,
which may result into large charges. A model for describing the
interaction of one twisted pair in a UTP (Unshielded Twisted
Pair) cable is presented in [2] using a three body model
analyzed from an electrostatic point of view. In [3] a system for
discharging a cable using a relay on a test bed is presented, and
experimental results are shown. In regards to the measurement
analysis side of Ethernet CDE, there are few publications
discussing the phenomena. Some ESD test setup have been
developed to repeat ESD current transfer through Ethernet
magnetic effects in [4] and [5].
The focus of this article is to present a CDE testing system
that will allow for real world test conditions to be reproduced
in the laboratory, thereby providing design engineers a quick
and reliable method for testing new hardware designs. The test
system will allow for different types of copper based Ethernet
cables, and twisted pair termination strategies. Further, full
control of the charge and discharge sequence of each cable line
allows for all possible cases to be explored.
II. IMPORTANT PARAMETERS IN ETHERNET CDE
Prior to discussing the CDE test system, a few important
parameters of copper based Ethernet cable CDE, especially
UTP must be reviewed.
A. Parameters of the charged Ethernet cable affecting CDE
Several important parameters must be considered in UTP
cables. The first parameter is the charging processes in UTP
cables. In particular, the wires can be charged due to charges
on the outside of the jacket, due to migration of charges through
the jacket and insulation to the wires, or due to direct contact of
the wires with a charged object. The voltage magnitude can be
as high as 2 kV. In most cases all wires will be charged to the
same voltage. If the spatial arrangement of the cables is
changed, the capacitance between the charged wires and
ground will also change, which can further increase the charge
voltage.
Another important parameter to consider is that there are
shielded and unshielded cables for Ethernet. These cable types
are illustrated in Fig. 1. They all maintain 100 Ohm differential
impedance for each twisted pair, but the unshielded cable will
have relatively large common mode impedance (100-300 Ohm)
versus the shielded cables because their current path is
physically far from the ground as compared to the shielded
wires. This common mode impedance plays a critical role in
the magnitude and to a lesser extend in the shape of the CDE
discharge current waveform.
Fig 1. Different shielding types of Ethernet cables
B. The termination of the Ethernet device
Load terminations also play an important role in the
characterization of a CDE. Many different types of termination
schemes exist, however, the most commonly used is the Bob
Smith Termination [5]. This termination uses a 75  resistor
for a common mode impedance match at each signal pair, and
they all connect via a high voltage capacitor to chassis ground
as shown in Fig 2. The isolation between the Ethernet
connector/chassis and internal PHY circuit is established
through a transformer and some designs incorporate common
mode chokes to further reduce common mode current
motivated EMI concerns. Further variations of the Bob Smith
circuit can be found in power over Ethernet applications, and
strongly cost reduced designs.
Fig 2. Typical termination of Ethernet device.
One pin will make the first contact and any other pin will
contact next. The initial contact leads to a charge redistribution,
a partial discharge of the total charge on the cable, and it can
charge the capacitor used in the Bob Smith circuit. Depending
on the contact sequence, various common mode and differential
mode termination plus the PHY IC circuit determine the load
of the discharge current path and therefore are the important
factors that determine the CDE current waveform.
C. The ESD events during CDE
The Ethernet cable connection includes several metal to
metal contacts, which can lead to multiple ESD events during
connection. For the case of plugging a shielded Ethernet cable
into a shielded Ethernet connector, the first ESD event is the
discharge between the shielding of the cable to the shielding of
Ethernet connector as this is the first contact point. Normally
this ESD is not likely to cause any failures if the DUT is
shielded. For the case of an unshielded cable or an unshielded
Ethernet connector the current must flow in the wires of the
UTP.
When an Ethernet cable is plugged into a connector, many
possible contact sequences can occur. Theoretically there could
be eight separate ESD events, one for each pin. However, each
contact will minimize the voltage between the other pins and
the connector.
This is caused by the large mutual capacitance between the
wires, and by charging the Bob Smith Termination.
To illustrate the charging of the capacitor in the Bob Smith
circuit, a 100 m long shielded cable was charged to 100 V
between the shield and its wires and inserted into an Ethernet
device. A result from this experiment is shown in Fig 3.
Because the capacitance between the wires and the shield is
much larger than the 1000 pF capacitor, the voltage reaches
over 90 V immediately after first contact, thereby lowering the
voltage difference between other connecting pins. For the next
seven contact events the voltage difference across the contacts
is drastically reduced..
The voltage waveform shown in Fig 3 gradually diminishes
due to the 100 M resistive voltage probe used in the
measurement. Without this drain path the voltage on the cable
will remain high for a very long time after the connection is
made. If the other end of this cable is plugged into an Ethernet
device another cable discharge event may occur.
Fig 3. Voltage across the 1 nF HV capacitor in the Bob Smith termination
during CDE.
Because the differential pairs of the cable have a well-
defined 100  discharge impedance, after the first wire has
made contact and the high voltage capacitor has a low
impedance path to ground, such that the second wire also
experiences the discharge as it is making contact, resulting in a
differential ESD event. This differential ESD current can easily
transfer through the magnetics to the isolated PHY circuit,
which is hazardous for the PHY chip.
III. THE ETHERNET CDE TEST SYSTEM CONCEPT
A good Ethernet CDE test setup should be able to control as
many of the parameters related to the cable discharge event as
possible, and provide a repeatable test. To do this the setup
must have these three main components; a Controller, a Charge
Module, and a Failure Test Monitor.
The Controller must have the capability to control cable
charge voltage and polarity, charge and discharge different
types of Ethernet cable arrangements, and separately control
the charging, floating, grounding, or discharge of each wire. In
addition, the test system should maintain the electrical
characteristic of the entire discharge current path as close to real
world CDE cases as possible. In particular, it should control
common and differential mode impedance of each pair, and the
contact sequence delay time between each discharge to the
same order of magnitude of a real cable as it is plugged into a
device.
The Charge Module represents the Ethernet cable used as the
discharge source for the CDE event. This consists of different
lengths of various CAT5 cable types. For research purposes,
different types of cables and how they are arranged must be
studied. For industry testing purposes, a good charge module
will provide a worst case, real world CDE source.
The Failure Test Monitor provides a means for verifying the
Ethernet performance. It will check if a failure has occurred,
or simply if a degradation in communication speed has
occurred. It is important this is automated due to the vast array
of tests that can be performed to check all discharge sequences.
A general block diagram of the CDE test system is shown in
Fig 4.
Fig. 4. A CDE Test System Concept.
A. CDE Test Controller
The main CDE test controller consists of high voltage
supplies (dual polarity), relays to separately control the
connection of each Ethernet cable wire, including whether it is
charging, floating, or grounded. The relays are bounce free and
provide a clean discharge for each wire. The transmission lines
on the board maintain the controlled 100  differential pair
structure of the Ethernet cable, and current probes are
embedded into each wire to monitor CDE discharge current.
The system also has remote control capability integrated into
the upper level system as a part of the automatic test equipment
(ATE). A simplified diagram of the main CDE controller is
shown in Fig 5.
HV+ HV-
High Voltage
Supply Relay
SMA I 1
Discharge
Relays
Charging Relays
Switch HV or
Ground/Floating
PCB
transmission line pair
1 of 4
twisted
pairs
LAN In
Connector
LAN Out
Connector
1 meter CAT5E Cable
DUT
Charge
Module
Current Probe
5 V/A
SMA I 2
CAT5E
UTP
DUT HV Cap
Discharge
Relay
8 wires share 1
discharge path
DIP Switch
to GND
The CDE Main Controller
Fig 5. The simplified schematic of CDE main controller with connection to
Ethernet cable charge module and DUT for one differential pair.
A common test procedure may consist of the following four
steps, as illustrated by the block diagram in Fig 6.
Fig 6. CDE test procedure.
1. Charge cable status control
The controller separately controls the voltage (level and
polarity) for each wire in the cable bundle. This includes the
status of each wire indicating if it is charged, floating,
grounded, or a through path.
2. Pre-discharge preparation
The controller will disconnect the charging path from
each wire in the Ethernet cable bundle and disconnect the
DUT discharge path between the DUT connector and ground.
This will leave all wires floating before the discharge step.
3. Control wire discharge while monitoring ESD Current
The controller will close the relays allowing the wires
coming from the charge line to discharge into the DUT or
termination load. The sequence of the relay closure and the
delay between relay closures can be set by the user.
4. Preparation after a discharge and check DUT status
The controller will open all cable discharge relays such
that the cable can be charged again. To charge the wires the
high voltage charging relays are closed. In additional all
remaining charges on the DUT need to be removed. This is
achieved by closing the DUT discharge relays.
The controller will open all cable discharge relays, then
close all high voltage charging relays and DUT connector
discharge relays to prepare for next CDE test.
B. Charge Module
In real world Ethernet cable installations there are many
different possibilities in regard to cable type and arrangements,
leading to unlimited test scenarios. Some common real world
arrangements are:
A. Cable hanging on the celling (relatively far from ground)
B. Cable on the floor (very close to the ground)
C. A spool of new cable
D. Cable pulled through conduit (very close to the ground)
Fig 7. A rack mount 200 meters of UTP cable Charge Module.
C. Failure Test Module
Besides the setup for CDE test control, it is also important to
test for normal Ethernet performance and functionality. It is
important to understand the effects of applied CDE on the DUT,
and as in the block diagram of Fig 4, an Ethernet traffic test
system should not only monitor the status of DUT during CDE
test, but also check the performance of the CDE applied ported
after each test level.
D. Calibration of the Ethernet CDE Test System
A CDE Tester (Model ES631-LAN) with two different types
of Ethernet Charge Modules (shielded and unshielded) was
built. The analysis of real discharge waveforms is difficult. For
that reason a proper calibration method with well-defined test
loads is important to verify the functionality, to understand the
current paths and the output parameters of the CDE test setup.
A set of calibration loads including short, open, and 100 
differential load were built using 10 cm CAT5E UTP cables,
and are shown in Fig 8.
Fig 8. CDE calibration loads: short, open, and 100 differential termination
The EIA 568B cable standard was used for all Ethernet
wiring, Fig 9.
Fig 9. EIA 568B Ethernet Wiring Standard.
In the measurement setup the oscilloscope was set to capture
the waveforms: Channel 1-voltage on line 5, Channel 2-current
on line 5, Channel 3-voltage on line 4, and Channel 4-current
on line 4. The voltage probes were 1010:1 (5 k/50  resistor
bridge = 101:1, plus 20 dB attenuator). And the current probes
were 20:1 (5 V/A plus 40 dB attenuator). The CDE Controller
in all tests was set to 500 V, and depending on the test
configuration the Charge Module and DUT may have been
grounded.
Setup 1 consisted of a short connected to CDE Controller
output, one differential pair with one side grounded and pre-
connected to the load, and a 100 meter Charge Module using
S/UTP cable with the chassis not grounded. The setup and
measurement waveforms are shown in Fig 10. From the
simplified circuit, after the relay is closed in line 5, we expect
a large current flowing from line 5 to line 4 over the differential
100  transmission line structure and the peak current should
be 5 A (500 V/100 ). From the waveforms it can be
confirmed that the current waveform starts with 5 A peak.
Then the waveform shows significant cable loss as the
waveforms rapidly decay. After the current reaches the cable
ends, reflections occur due to mismatches and several
reflections happen until the total signal approaches zero. The
voltage is a RC discharge waveform through the voltage
measurement path.
Fig 10. Simplified schematic and waveforms of CDE calibration setup 1.
Setup 2 is similar to setup 1 except the charge module chassis
is connected to ground. The setup and measurement waveforms
are shown in Fig 11. As can be seen, the current waveforms
are the same as the first setup, but the voltage waveform RC
time constant is much larger due to the grounding of the Charge
Module chassis.
Fig. 11. Simplified schematic and waveforms of CDE calibration setup 2.
Setup 3 consisted of an open load connected to the CDE
Controller output, one differential pair with one side grounded
and pre-connected to the load, and a 100 meter Charge Module
using S/UTP cable and chassis grounded. The setup and
measurement waveforms are shown in Fig 12. There is little
displacement current as the load is an open, and the voltage on
line 5 is 494 V peak, which is very close to the charge voltage.
Fig 12. Simplified schematic and waveforms of CDE calibration setup 3.
Setup 4 consisted of a 100  load (with center tap between
two 50  resistors grounded) connected to the CDE Controller
output, one differential pair with one side grounded and pre-
connected to the load, and a 100 meter Charge Module using
S/UTP cable and chassis grounded. The setup and
measurement waveforms are shown in Fig 13. With the 100 
load in place the current waveform magnitude drops to half of
that measured with the short as in setups 1 and 2, and there are
no reflections.
Fig. 13. Simplified schematic and waveforms of CDE calibration setup 4.
Except for the shape and magnitude of the measured
calibration waveforms, the time delay of the measurement is
also important to understand, in particular, which part of the
waveform is due to the 100  transmission line extension, and
which part is due to the DUT. The waveforms shown in Fig 14
are with the CDE Controller connected to a CAT5E UTP cable
only. The current waveform shows the 100  transmission line
extension first, then the open end. The real measurement of the
DUT starts at the time where the open is shown.
Fig 14. CDE Controller with CAT5E UTP cable as only load.
E. Test of the CDE System on Ethernet Systems
Two 10/100Mbps Ethernet DUTs were tested with the CDE
test system as shown in Fig 15. The test parameters are: CDE
source voltage of 1 kV, a 100 meter Charge Module using
S/UTP cable, and oscilloscope channels are scaled to 1 A/div.
The first pin discharge waveform is captured and compared
between unit A and unit B. Unit B has a much smaller current
peak and higher current duration. This is mainly because the
common mode impedance of unit B is much smaller than unit
A.
Fig. 15. Current measurement of first pin discharge between 2 DUTs.
Most systems using the Bob Smith Termination are almost
fully charged after the initial discharge, so the current
magnitude of the 2nd
- 8th
discharges are too small compared to
the first one. This is not discussed here.
Fig 16. CDE test of a charged UTP discharging into a POE system.
A Power over Ethernet (POE) system, having more complex
termination was also tested. The measurement waveforms are
shown in Fig 16. When the first pin contact DUT, first
discharge current is generated in common mode through this
pin. Then when the other wire in the same twisted pair contacts
DUT, another discharge current is generated in differential
mode through this pair. Both discharge signals could be
transferred from termination to PHY circuit leading to damage
in the Ethernet system.
IV.CONCLUSION
In this article, several important physics for CDEs have been
discussed, a general CDE test and measurement solution
developed, and some test results with well-defined structures
and a few real world Ethernet systems are presented and
discussed.
The next steps for CDE related test and measurement would
be modeling the overall test system with different terminations,
and running more tests with Ethernet systems to understand the
design principle for CDE.
ACKNOWLEDGMENT
We would like to thank the EMC Laboratory, Missouri
University of Science and Technology for the partnership of
CDE related study and research and Cisco for the partnership
in CDE related tests and measurements.
REFERENCES
[1] H. Michael, “Cable Discharge Events”, Part I & II, ESD Open Forum
2009.
[2] W. Greason, “Analysis of Cable Discharge Events (CDE),” 2009
Electrostatics Joint Conference
[3] S. Wolfgang, B. Tilo, N. Josef, G. Reinhold, M. Kathleen,
“Characterization and Simulation of Real-World Cable Discharge
Events”, EOS/ESD Symposium 2009
[4] P. Neven, “ESD TRANSFER THROUGH ETHERNET MAGNETICS”,
IEEE EMC 2005, pp. 356-363.
[5] Texas Instrument, “AN-1511 Cable Discharge Event”. [Online].
Available: http://www.ti.com/lit/an/snla087a/snla087a.pdf .

More Related Content

What's hot

EFFECT OF ELECTROMAGNETICE FIELD (EMI).
EFFECT OF ELECTROMAGNETICE FIELD (EMI).EFFECT OF ELECTROMAGNETICE FIELD (EMI).
EFFECT OF ELECTROMAGNETICE FIELD (EMI).Arshad Hussain
 
Emi and emc
Emi and emcEmi and emc
Emi and emcashmad
 
possible emc slides
possible emc slidespossible emc slides
possible emc slidesWissam Fawaz
 
Fundamentals of electromagnetic compatibility (EMC)
Fundamentals of electromagnetic compatibility (EMC)Fundamentals of electromagnetic compatibility (EMC)
Fundamentals of electromagnetic compatibility (EMC)Bruno De Wachter
 
Electromagnetic Interference and Electromagnetic Compatibility (EMI/EMC
Electromagnetic Interference and Electromagnetic Compatibility (EMI/EMCElectromagnetic Interference and Electromagnetic Compatibility (EMI/EMC
Electromagnetic Interference and Electromagnetic Compatibility (EMI/EMCAishwary Singh
 
A Non-Contact Type Comb Drive for the Removal of Stiction Mechanism in MEMS S...
A Non-Contact Type Comb Drive for the Removal of Stiction Mechanism in MEMS S...A Non-Contact Type Comb Drive for the Removal of Stiction Mechanism in MEMS S...
A Non-Contact Type Comb Drive for the Removal of Stiction Mechanism in MEMS S...idescitation
 
Presentation-Telemetrics Equipments Pvt Ltd
Presentation-Telemetrics Equipments Pvt LtdPresentation-Telemetrics Equipments Pvt Ltd
Presentation-Telemetrics Equipments Pvt LtdAruna Narayan
 
Electro magnetic interference and compatibility(ECM,ECI)
Electro magnetic interference and compatibility(ECM,ECI)Electro magnetic interference and compatibility(ECM,ECI)
Electro magnetic interference and compatibility(ECM,ECI)Palani murugan
 
Simulation study of single event effects sensitivity on commercial power MOSF...
Simulation study of single event effects sensitivity on commercial power MOSF...Simulation study of single event effects sensitivity on commercial power MOSF...
Simulation study of single event effects sensitivity on commercial power MOSF...journalBEEI
 
Grounding of Multi Cable Transits for on-shore use
Grounding of Multi Cable Transits for on-shore useGrounding of Multi Cable Transits for on-shore use
Grounding of Multi Cable Transits for on-shore useMathieu Melenhorst
 
New project report
New project reportNew project report
New project reportSai Printers
 
CP Cases - What is electromagnetic shielding?
CP Cases - What is electromagnetic shielding?CP Cases - What is electromagnetic shielding?
CP Cases - What is electromagnetic shielding?CP Cases
 
wireless power transfer
wireless power transferwireless power transfer
wireless power transferhetvi naik
 
Emi emc-pdf
Emi emc-pdfEmi emc-pdf
Emi emc-pdfnagastra
 

What's hot (20)

ARR_Presentation
ARR_PresentationARR_Presentation
ARR_Presentation
 
EFFECT OF ELECTROMAGNETICE FIELD (EMI).
EFFECT OF ELECTROMAGNETICE FIELD (EMI).EFFECT OF ELECTROMAGNETICE FIELD (EMI).
EFFECT OF ELECTROMAGNETICE FIELD (EMI).
 
Emi and emc
Emi and emcEmi and emc
Emi and emc
 
possible emc slides
possible emc slidespossible emc slides
possible emc slides
 
wireless power transfer
wireless power transferwireless power transfer
wireless power transfer
 
Fundamentals of electromagnetic compatibility (EMC)
Fundamentals of electromagnetic compatibility (EMC)Fundamentals of electromagnetic compatibility (EMC)
Fundamentals of electromagnetic compatibility (EMC)
 
Electromagnetic Interference and Electromagnetic Compatibility (EMI/EMC
Electromagnetic Interference and Electromagnetic Compatibility (EMI/EMCElectromagnetic Interference and Electromagnetic Compatibility (EMI/EMC
Electromagnetic Interference and Electromagnetic Compatibility (EMI/EMC
 
A Non-Contact Type Comb Drive for the Removal of Stiction Mechanism in MEMS S...
A Non-Contact Type Comb Drive for the Removal of Stiction Mechanism in MEMS S...A Non-Contact Type Comb Drive for the Removal of Stiction Mechanism in MEMS S...
A Non-Contact Type Comb Drive for the Removal of Stiction Mechanism in MEMS S...
 
Emi and emc
Emi and emcEmi and emc
Emi and emc
 
Presentation-Telemetrics Equipments Pvt Ltd
Presentation-Telemetrics Equipments Pvt LtdPresentation-Telemetrics Equipments Pvt Ltd
Presentation-Telemetrics Equipments Pvt Ltd
 
Electro magnetic interference and compatibility(ECM,ECI)
Electro magnetic interference and compatibility(ECM,ECI)Electro magnetic interference and compatibility(ECM,ECI)
Electro magnetic interference and compatibility(ECM,ECI)
 
Simulation study of single event effects sensitivity on commercial power MOSF...
Simulation study of single event effects sensitivity on commercial power MOSF...Simulation study of single event effects sensitivity on commercial power MOSF...
Simulation study of single event effects sensitivity on commercial power MOSF...
 
Wireless SYSTEM
Wireless SYSTEMWireless SYSTEM
Wireless SYSTEM
 
Grounding of Multi Cable Transits for on-shore use
Grounding of Multi Cable Transits for on-shore useGrounding of Multi Cable Transits for on-shore use
Grounding of Multi Cable Transits for on-shore use
 
Presentationwirelesspowertransfer
PresentationwirelesspowertransferPresentationwirelesspowertransfer
Presentationwirelesspowertransfer
 
New project report
New project reportNew project report
New project report
 
CP Cases - What is electromagnetic shielding?
CP Cases - What is electromagnetic shielding?CP Cases - What is electromagnetic shielding?
CP Cases - What is electromagnetic shielding?
 
Hs Emc
Hs EmcHs Emc
Hs Emc
 
wireless power transfer
wireless power transferwireless power transfer
wireless power transfer
 
Emi emc-pdf
Emi emc-pdfEmi emc-pdf
Emi emc-pdf
 

Similar to An Ethernet Cable Discharge Event (CDE) Test and Measurement System

Underground Cable Fault Detection Using IOT
Underground Cable Fault Detection Using IOTUnderground Cable Fault Detection Using IOT
Underground Cable Fault Detection Using IOTIRJET Journal
 
Simulation and detection of transients on a 150kV HV Cable-paper
Simulation and detection of transients on a 150kV HV Cable-paperSimulation and detection of transients on a 150kV HV Cable-paper
Simulation and detection of transients on a 150kV HV Cable-paperThomas Mathew
 
Electrical Power Supply System
Electrical Power Supply SystemElectrical Power Supply System
Electrical Power Supply SystemNAYEMAL
 
ECO-FRIENDLY CHARGING STATION
ECO-FRIENDLY CHARGING STATIONECO-FRIENDLY CHARGING STATION
ECO-FRIENDLY CHARGING STATIONIRJET Journal
 
POWER QUALITY AND THD MITIGATION IN ELECTRIC VEHICLE CHARGING STATION BY THE ...
POWER QUALITY AND THD MITIGATION IN ELECTRIC VEHICLE CHARGING STATION BY THE ...POWER QUALITY AND THD MITIGATION IN ELECTRIC VEHICLE CHARGING STATION BY THE ...
POWER QUALITY AND THD MITIGATION IN ELECTRIC VEHICLE CHARGING STATION BY THE ...IRJET Journal
 
Paper of Tahesin Samira Delwar_ IEEE Conf 2014
Paper of Tahesin Samira Delwar_ IEEE  Conf 2014Paper of Tahesin Samira Delwar_ IEEE  Conf 2014
Paper of Tahesin Samira Delwar_ IEEE Conf 2014TAHESIN SAMIRA DELWAR
 
Darkawi_et_al_CEIDP_2012_VF_IEEE
Darkawi_et_al_CEIDP_2012_VF_IEEEDarkawi_et_al_CEIDP_2012_VF_IEEE
Darkawi_et_al_CEIDP_2012_VF_IEEEAbdallah Darkawi
 
Underground Cable Fault Detection Using Arduino
Underground Cable Fault Detection Using ArduinoUnderground Cable Fault Detection Using Arduino
Underground Cable Fault Detection Using ArduinoIRJET Journal
 
“THE PROJECT REPORT ON WIRELESS CHARGING STATION FOR ELECTRIC VEHICLES WITH A...
“THE PROJECT REPORT ON WIRELESS CHARGING STATION FOR ELECTRIC VEHICLES WITH A...“THE PROJECT REPORT ON WIRELESS CHARGING STATION FOR ELECTRIC VEHICLES WITH A...
“THE PROJECT REPORT ON WIRELESS CHARGING STATION FOR ELECTRIC VEHICLES WITH A...IRJET Journal
 
Chapter8 emc
Chapter8 emcChapter8 emc
Chapter8 emcVin Voro
 
Introduction gadgets have gained a lot of attention.pdf
Introduction gadgets have gained a lot of attention.pdfIntroduction gadgets have gained a lot of attention.pdf
Introduction gadgets have gained a lot of attention.pdfbkbk37
 
ECE 6030 Device Electronics.docx
ECE 6030 Device Electronics.docxECE 6030 Device Electronics.docx
ECE 6030 Device Electronics.docxwrite31
 
Protection of Converter Dense Power Systems
Protection of Converter Dense Power Systems Protection of Converter Dense Power Systems
Protection of Converter Dense Power Systems Aditya Kumar Tripathy
 

Similar to An Ethernet Cable Discharge Event (CDE) Test and Measurement System (20)

voltage scaling
voltage scalingvoltage scaling
voltage scaling
 
B1102030610
B1102030610B1102030610
B1102030610
 
Ms 2443 final
Ms 2443 finalMs 2443 final
Ms 2443 final
 
ESDEMC CDE IEEE Symposium 2014
ESDEMC CDE IEEE Symposium 2014ESDEMC CDE IEEE Symposium 2014
ESDEMC CDE IEEE Symposium 2014
 
Underground Cable Fault Detection Using IOT
Underground Cable Fault Detection Using IOTUnderground Cable Fault Detection Using IOT
Underground Cable Fault Detection Using IOT
 
Simulation and detection of transients on a 150kV HV Cable-paper
Simulation and detection of transients on a 150kV HV Cable-paperSimulation and detection of transients on a 150kV HV Cable-paper
Simulation and detection of transients on a 150kV HV Cable-paper
 
Electrical Power Supply System
Electrical Power Supply SystemElectrical Power Supply System
Electrical Power Supply System
 
Review of DC Offset Compensation Techniques for Grid Connected Inverters
Review of DC Offset Compensation Techniques for Grid Connected InvertersReview of DC Offset Compensation Techniques for Grid Connected Inverters
Review of DC Offset Compensation Techniques for Grid Connected Inverters
 
00798333
0079833300798333
00798333
 
ECO-FRIENDLY CHARGING STATION
ECO-FRIENDLY CHARGING STATIONECO-FRIENDLY CHARGING STATION
ECO-FRIENDLY CHARGING STATION
 
Sheath bonding method for underground cables
Sheath bonding method for underground cablesSheath bonding method for underground cables
Sheath bonding method for underground cables
 
POWER QUALITY AND THD MITIGATION IN ELECTRIC VEHICLE CHARGING STATION BY THE ...
POWER QUALITY AND THD MITIGATION IN ELECTRIC VEHICLE CHARGING STATION BY THE ...POWER QUALITY AND THD MITIGATION IN ELECTRIC VEHICLE CHARGING STATION BY THE ...
POWER QUALITY AND THD MITIGATION IN ELECTRIC VEHICLE CHARGING STATION BY THE ...
 
Paper of Tahesin Samira Delwar_ IEEE Conf 2014
Paper of Tahesin Samira Delwar_ IEEE  Conf 2014Paper of Tahesin Samira Delwar_ IEEE  Conf 2014
Paper of Tahesin Samira Delwar_ IEEE Conf 2014
 
Darkawi_et_al_CEIDP_2012_VF_IEEE
Darkawi_et_al_CEIDP_2012_VF_IEEEDarkawi_et_al_CEIDP_2012_VF_IEEE
Darkawi_et_al_CEIDP_2012_VF_IEEE
 
Underground Cable Fault Detection Using Arduino
Underground Cable Fault Detection Using ArduinoUnderground Cable Fault Detection Using Arduino
Underground Cable Fault Detection Using Arduino
 
“THE PROJECT REPORT ON WIRELESS CHARGING STATION FOR ELECTRIC VEHICLES WITH A...
“THE PROJECT REPORT ON WIRELESS CHARGING STATION FOR ELECTRIC VEHICLES WITH A...“THE PROJECT REPORT ON WIRELESS CHARGING STATION FOR ELECTRIC VEHICLES WITH A...
“THE PROJECT REPORT ON WIRELESS CHARGING STATION FOR ELECTRIC VEHICLES WITH A...
 
Chapter8 emc
Chapter8 emcChapter8 emc
Chapter8 emc
 
Introduction gadgets have gained a lot of attention.pdf
Introduction gadgets have gained a lot of attention.pdfIntroduction gadgets have gained a lot of attention.pdf
Introduction gadgets have gained a lot of attention.pdf
 
ECE 6030 Device Electronics.docx
ECE 6030 Device Electronics.docxECE 6030 Device Electronics.docx
ECE 6030 Device Electronics.docx
 
Protection of Converter Dense Power Systems
Protection of Converter Dense Power Systems Protection of Converter Dense Power Systems
Protection of Converter Dense Power Systems
 

More from ESDEMC Technology LLC

ESDEMC_PB2009.08 A Measurement Technique for ESD Current Spreading on A PCB u...
ESDEMC_PB2009.08 A Measurement Technique for ESD Current Spreading on A PCB u...ESDEMC_PB2009.08 A Measurement Technique for ESD Current Spreading on A PCB u...
ESDEMC_PB2009.08 A Measurement Technique for ESD Current Spreading on A PCB u...ESDEMC Technology LLC
 
ESDEMC_PB2014.08 An Ethernet Cable Discharge Event (CDE) Test and Measurement...
ESDEMC_PB2014.08 An Ethernet Cable Discharge Event (CDE) Test and Measurement...ESDEMC_PB2014.08 An Ethernet Cable Discharge Event (CDE) Test and Measurement...
ESDEMC_PB2014.08 An Ethernet Cable Discharge Event (CDE) Test and Measurement...ESDEMC Technology LLC
 
Pb2012.01 an application of utilizing the system efficient-esd-design (seed) ...
Pb2012.01 an application of utilizing the system efficient-esd-design (seed) ...Pb2012.01 an application of utilizing the system efficient-esd-design (seed) ...
Pb2012.01 an application of utilizing the system efficient-esd-design (seed) ...ESDEMC Technology LLC
 
Pb2003.01 problems with the electrostatic discharge (esd) immunity test in el...
Pb2003.01 problems with the electrostatic discharge (esd) immunity test in el...Pb2003.01 problems with the electrostatic discharge (esd) immunity test in el...
Pb2003.01 problems with the electrostatic discharge (esd) immunity test in el...ESDEMC Technology LLC
 
ESDEMC TS004 TVS Failure Level Tests Comparison Between ESD Gun, TLP & HMM
ESDEMC TS004 TVS Failure Level Tests Comparison Between ESD Gun, TLP & HMMESDEMC TS004 TVS Failure Level Tests Comparison Between ESD Gun, TLP & HMM
ESDEMC TS004 TVS Failure Level Tests Comparison Between ESD Gun, TLP & HMMESDEMC Technology LLC
 
ESDEMC TS003 Characterizing Touch Panel Sensor ESD Failure with IV-Curve TLP
ESDEMC TS003 Characterizing Touch Panel Sensor ESD Failure with IV-Curve TLPESDEMC TS003 Characterizing Touch Panel Sensor ESD Failure with IV-Curve TLP
ESDEMC TS003 Characterizing Touch Panel Sensor ESD Failure with IV-Curve TLPESDEMC Technology LLC
 
用于ESD分析的传输线脉冲测试 (Transmission Line Pulse - TLP Measurement) 元件级
用于ESD分析的传输线脉冲测试 (Transmission Line Pulse  - TLP Measurement) 元件级用于ESD分析的传输线脉冲测试 (Transmission Line Pulse  - TLP Measurement) 元件级
用于ESD分析的传输线脉冲测试 (Transmission Line Pulse - TLP Measurement) 元件级ESDEMC Technology LLC
 
Introduction of Transmission Line Pulse (TLP) Testing for ESD Analysis - De...
Introduction of  Transmission Line Pulse (TLP) Testing for ESD Analysis  - De...Introduction of  Transmission Line Pulse (TLP) Testing for ESD Analysis  - De...
Introduction of Transmission Line Pulse (TLP) Testing for ESD Analysis - De...ESDEMC Technology LLC
 

More from ESDEMC Technology LLC (9)

ESDEMC ES620 TLP System Comparison
ESDEMC ES620 TLP System ComparisonESDEMC ES620 TLP System Comparison
ESDEMC ES620 TLP System Comparison
 
ESDEMC_PB2009.08 A Measurement Technique for ESD Current Spreading on A PCB u...
ESDEMC_PB2009.08 A Measurement Technique for ESD Current Spreading on A PCB u...ESDEMC_PB2009.08 A Measurement Technique for ESD Current Spreading on A PCB u...
ESDEMC_PB2009.08 A Measurement Technique for ESD Current Spreading on A PCB u...
 
ESDEMC_PB2014.08 An Ethernet Cable Discharge Event (CDE) Test and Measurement...
ESDEMC_PB2014.08 An Ethernet Cable Discharge Event (CDE) Test and Measurement...ESDEMC_PB2014.08 An Ethernet Cable Discharge Event (CDE) Test and Measurement...
ESDEMC_PB2014.08 An Ethernet Cable Discharge Event (CDE) Test and Measurement...
 
Pb2012.01 an application of utilizing the system efficient-esd-design (seed) ...
Pb2012.01 an application of utilizing the system efficient-esd-design (seed) ...Pb2012.01 an application of utilizing the system efficient-esd-design (seed) ...
Pb2012.01 an application of utilizing the system efficient-esd-design (seed) ...
 
Pb2003.01 problems with the electrostatic discharge (esd) immunity test in el...
Pb2003.01 problems with the electrostatic discharge (esd) immunity test in el...Pb2003.01 problems with the electrostatic discharge (esd) immunity test in el...
Pb2003.01 problems with the electrostatic discharge (esd) immunity test in el...
 
ESDEMC TS004 TVS Failure Level Tests Comparison Between ESD Gun, TLP & HMM
ESDEMC TS004 TVS Failure Level Tests Comparison Between ESD Gun, TLP & HMMESDEMC TS004 TVS Failure Level Tests Comparison Between ESD Gun, TLP & HMM
ESDEMC TS004 TVS Failure Level Tests Comparison Between ESD Gun, TLP & HMM
 
ESDEMC TS003 Characterizing Touch Panel Sensor ESD Failure with IV-Curve TLP
ESDEMC TS003 Characterizing Touch Panel Sensor ESD Failure with IV-Curve TLPESDEMC TS003 Characterizing Touch Panel Sensor ESD Failure with IV-Curve TLP
ESDEMC TS003 Characterizing Touch Panel Sensor ESD Failure with IV-Curve TLP
 
用于ESD分析的传输线脉冲测试 (Transmission Line Pulse - TLP Measurement) 元件级
用于ESD分析的传输线脉冲测试 (Transmission Line Pulse  - TLP Measurement) 元件级用于ESD分析的传输线脉冲测试 (Transmission Line Pulse  - TLP Measurement) 元件级
用于ESD分析的传输线脉冲测试 (Transmission Line Pulse - TLP Measurement) 元件级
 
Introduction of Transmission Line Pulse (TLP) Testing for ESD Analysis - De...
Introduction of  Transmission Line Pulse (TLP) Testing for ESD Analysis  - De...Introduction of  Transmission Line Pulse (TLP) Testing for ESD Analysis  - De...
Introduction of Transmission Line Pulse (TLP) Testing for ESD Analysis - De...
 

Recently uploaded

(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escortsranjana rawat
 
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ
 
IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024Mark Billinghurst
 
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...srsj9000
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...Soham Mondal
 
power system scada applications and uses
power system scada applications and usespower system scada applications and uses
power system scada applications and usesDevarapalliHaritha
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝soniya singh
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130Suhani Kapoor
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxpurnimasatapathy1234
 
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective IntroductionSachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective IntroductionDr.Costas Sachpazis
 
main PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfidmain PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfidNikhilNagaraju
 
Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...VICTOR MAESTRE RAMIREZ
 
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfAsst.prof M.Gokilavani
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girlsssuser7cb4ff
 

Recently uploaded (20)

(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
 
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
 
IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024
 
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Serviceyoung call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
 
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
 
power system scada applications and uses
power system scada applications and usespower system scada applications and uses
power system scada applications and uses
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
 
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptx
 
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective IntroductionSachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
 
main PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfidmain PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfid
 
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
 
Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...
 
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girls
 
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
 

An Ethernet Cable Discharge Event (CDE) Test and Measurement System

  • 1. An Ethernet Cable Discharge Event (CDE) Test and Measurement System Wei Huang, Jerry Tichenor ESDEMC Technology LLC Rolla, MO, USA whuang@esdemc.com David Pommerenke, Viswa Pilla, Pratik Maheshwari, Giorgi Maghlakelidze Electromagnetic Compatibility Laboratory, Missouri S&T Rolla, MO, USA davidjp@mst.edu Abstract— A Cable Discharge Event (CDE) is an electrostatic discharge between a cable and a connector. CDEs occur on unshielded Ethernet based communication interfaces and inject currents into the pins directly [1-3]. The charging processes are in general understood; however, the discharge processes are complicated due to the number of pins involved and their connections to a system. Based on an understanding of the factors which determine the severity of a CDE, this article describes how to setup a variety of repeatable CDE tests and how to analyze the measurement results. Keywords— Cable Discharge Event (CDE) Test; Cable ESD; I. INTRODUCTION Both occurrence rate and severity of a CDE needs to be considered when determining the importance of dedicated CDE tests to ensure a reliable system. The occurrence rate of a CDE depends on the type of connector used and the environment the system is used. While a USB connector on a laptop will receive many more ESD events than a LAN connector, the LAN connector still poses a larger risk to the system as it is usually not shielded and often used in applications that require high reliability such as back bone internet routers. In contrast to a USB connector, a LAN connector can have a spark from the connector to a pin during a CDE. In the case of USB connectors the connector shells will mate first. Provided that the shells are connected to the shield and to the system ground, most of the discharge current will flow on the connector shells. For the LAN CDE case a good understanding of the dominating processes provides a mean for developing and validating models. These models will allow computer simulation, and laboratory test setup formulation for reproducing real CDEs. This is crucial for IC and system level engineers to study and optimize the immunity of Ethernet based communications interface designs. It is well known that triboelectric charging is the culprit that generates the charge on a cable [1],[2]. This fact is especially important in Ethernet communication systems due to the long lengths of UPT cable that must be pulled through conduit, which may result into large charges. A model for describing the interaction of one twisted pair in a UTP (Unshielded Twisted Pair) cable is presented in [2] using a three body model analyzed from an electrostatic point of view. In [3] a system for discharging a cable using a relay on a test bed is presented, and experimental results are shown. In regards to the measurement analysis side of Ethernet CDE, there are few publications discussing the phenomena. Some ESD test setup have been developed to repeat ESD current transfer through Ethernet magnetic effects in [4] and [5]. The focus of this article is to present a CDE testing system that will allow for real world test conditions to be reproduced in the laboratory, thereby providing design engineers a quick and reliable method for testing new hardware designs. The test system will allow for different types of copper based Ethernet cables, and twisted pair termination strategies. Further, full control of the charge and discharge sequence of each cable line allows for all possible cases to be explored. II. IMPORTANT PARAMETERS IN ETHERNET CDE Prior to discussing the CDE test system, a few important parameters of copper based Ethernet cable CDE, especially UTP must be reviewed. A. Parameters of the charged Ethernet cable affecting CDE Several important parameters must be considered in UTP cables. The first parameter is the charging processes in UTP cables. In particular, the wires can be charged due to charges on the outside of the jacket, due to migration of charges through the jacket and insulation to the wires, or due to direct contact of the wires with a charged object. The voltage magnitude can be as high as 2 kV. In most cases all wires will be charged to the same voltage. If the spatial arrangement of the cables is changed, the capacitance between the charged wires and ground will also change, which can further increase the charge voltage. Another important parameter to consider is that there are shielded and unshielded cables for Ethernet. These cable types are illustrated in Fig. 1. They all maintain 100 Ohm differential impedance for each twisted pair, but the unshielded cable will have relatively large common mode impedance (100-300 Ohm) versus the shielded cables because their current path is physically far from the ground as compared to the shielded wires. This common mode impedance plays a critical role in the magnitude and to a lesser extend in the shape of the CDE discharge current waveform.
  • 2. Fig 1. Different shielding types of Ethernet cables B. The termination of the Ethernet device Load terminations also play an important role in the characterization of a CDE. Many different types of termination schemes exist, however, the most commonly used is the Bob Smith Termination [5]. This termination uses a 75  resistor for a common mode impedance match at each signal pair, and they all connect via a high voltage capacitor to chassis ground as shown in Fig 2. The isolation between the Ethernet connector/chassis and internal PHY circuit is established through a transformer and some designs incorporate common mode chokes to further reduce common mode current motivated EMI concerns. Further variations of the Bob Smith circuit can be found in power over Ethernet applications, and strongly cost reduced designs. Fig 2. Typical termination of Ethernet device. One pin will make the first contact and any other pin will contact next. The initial contact leads to a charge redistribution, a partial discharge of the total charge on the cable, and it can charge the capacitor used in the Bob Smith circuit. Depending on the contact sequence, various common mode and differential mode termination plus the PHY IC circuit determine the load of the discharge current path and therefore are the important factors that determine the CDE current waveform. C. The ESD events during CDE The Ethernet cable connection includes several metal to metal contacts, which can lead to multiple ESD events during connection. For the case of plugging a shielded Ethernet cable into a shielded Ethernet connector, the first ESD event is the discharge between the shielding of the cable to the shielding of Ethernet connector as this is the first contact point. Normally this ESD is not likely to cause any failures if the DUT is shielded. For the case of an unshielded cable or an unshielded Ethernet connector the current must flow in the wires of the UTP. When an Ethernet cable is plugged into a connector, many possible contact sequences can occur. Theoretically there could be eight separate ESD events, one for each pin. However, each contact will minimize the voltage between the other pins and the connector. This is caused by the large mutual capacitance between the wires, and by charging the Bob Smith Termination. To illustrate the charging of the capacitor in the Bob Smith circuit, a 100 m long shielded cable was charged to 100 V between the shield and its wires and inserted into an Ethernet device. A result from this experiment is shown in Fig 3. Because the capacitance between the wires and the shield is much larger than the 1000 pF capacitor, the voltage reaches over 90 V immediately after first contact, thereby lowering the voltage difference between other connecting pins. For the next seven contact events the voltage difference across the contacts is drastically reduced.. The voltage waveform shown in Fig 3 gradually diminishes due to the 100 M resistive voltage probe used in the measurement. Without this drain path the voltage on the cable will remain high for a very long time after the connection is made. If the other end of this cable is plugged into an Ethernet device another cable discharge event may occur. Fig 3. Voltage across the 1 nF HV capacitor in the Bob Smith termination during CDE. Because the differential pairs of the cable have a well- defined 100  discharge impedance, after the first wire has made contact and the high voltage capacitor has a low impedance path to ground, such that the second wire also experiences the discharge as it is making contact, resulting in a differential ESD event. This differential ESD current can easily transfer through the magnetics to the isolated PHY circuit, which is hazardous for the PHY chip. III. THE ETHERNET CDE TEST SYSTEM CONCEPT A good Ethernet CDE test setup should be able to control as many of the parameters related to the cable discharge event as possible, and provide a repeatable test. To do this the setup must have these three main components; a Controller, a Charge Module, and a Failure Test Monitor.
  • 3. The Controller must have the capability to control cable charge voltage and polarity, charge and discharge different types of Ethernet cable arrangements, and separately control the charging, floating, grounding, or discharge of each wire. In addition, the test system should maintain the electrical characteristic of the entire discharge current path as close to real world CDE cases as possible. In particular, it should control common and differential mode impedance of each pair, and the contact sequence delay time between each discharge to the same order of magnitude of a real cable as it is plugged into a device. The Charge Module represents the Ethernet cable used as the discharge source for the CDE event. This consists of different lengths of various CAT5 cable types. For research purposes, different types of cables and how they are arranged must be studied. For industry testing purposes, a good charge module will provide a worst case, real world CDE source. The Failure Test Monitor provides a means for verifying the Ethernet performance. It will check if a failure has occurred, or simply if a degradation in communication speed has occurred. It is important this is automated due to the vast array of tests that can be performed to check all discharge sequences. A general block diagram of the CDE test system is shown in Fig 4. Fig. 4. A CDE Test System Concept. A. CDE Test Controller The main CDE test controller consists of high voltage supplies (dual polarity), relays to separately control the connection of each Ethernet cable wire, including whether it is charging, floating, or grounded. The relays are bounce free and provide a clean discharge for each wire. The transmission lines on the board maintain the controlled 100  differential pair structure of the Ethernet cable, and current probes are embedded into each wire to monitor CDE discharge current. The system also has remote control capability integrated into the upper level system as a part of the automatic test equipment (ATE). A simplified diagram of the main CDE controller is shown in Fig 5. HV+ HV- High Voltage Supply Relay SMA I 1 Discharge Relays Charging Relays Switch HV or Ground/Floating PCB transmission line pair 1 of 4 twisted pairs LAN In Connector LAN Out Connector 1 meter CAT5E Cable DUT Charge Module Current Probe 5 V/A SMA I 2 CAT5E UTP DUT HV Cap Discharge Relay 8 wires share 1 discharge path DIP Switch to GND The CDE Main Controller Fig 5. The simplified schematic of CDE main controller with connection to Ethernet cable charge module and DUT for one differential pair. A common test procedure may consist of the following four steps, as illustrated by the block diagram in Fig 6. Fig 6. CDE test procedure. 1. Charge cable status control The controller separately controls the voltage (level and polarity) for each wire in the cable bundle. This includes the status of each wire indicating if it is charged, floating, grounded, or a through path. 2. Pre-discharge preparation The controller will disconnect the charging path from each wire in the Ethernet cable bundle and disconnect the DUT discharge path between the DUT connector and ground. This will leave all wires floating before the discharge step. 3. Control wire discharge while monitoring ESD Current The controller will close the relays allowing the wires coming from the charge line to discharge into the DUT or termination load. The sequence of the relay closure and the delay between relay closures can be set by the user. 4. Preparation after a discharge and check DUT status The controller will open all cable discharge relays such that the cable can be charged again. To charge the wires the high voltage charging relays are closed. In additional all remaining charges on the DUT need to be removed. This is achieved by closing the DUT discharge relays.
  • 4. The controller will open all cable discharge relays, then close all high voltage charging relays and DUT connector discharge relays to prepare for next CDE test. B. Charge Module In real world Ethernet cable installations there are many different possibilities in regard to cable type and arrangements, leading to unlimited test scenarios. Some common real world arrangements are: A. Cable hanging on the celling (relatively far from ground) B. Cable on the floor (very close to the ground) C. A spool of new cable D. Cable pulled through conduit (very close to the ground) Fig 7. A rack mount 200 meters of UTP cable Charge Module. C. Failure Test Module Besides the setup for CDE test control, it is also important to test for normal Ethernet performance and functionality. It is important to understand the effects of applied CDE on the DUT, and as in the block diagram of Fig 4, an Ethernet traffic test system should not only monitor the status of DUT during CDE test, but also check the performance of the CDE applied ported after each test level. D. Calibration of the Ethernet CDE Test System A CDE Tester (Model ES631-LAN) with two different types of Ethernet Charge Modules (shielded and unshielded) was built. The analysis of real discharge waveforms is difficult. For that reason a proper calibration method with well-defined test loads is important to verify the functionality, to understand the current paths and the output parameters of the CDE test setup. A set of calibration loads including short, open, and 100  differential load were built using 10 cm CAT5E UTP cables, and are shown in Fig 8. Fig 8. CDE calibration loads: short, open, and 100 differential termination The EIA 568B cable standard was used for all Ethernet wiring, Fig 9. Fig 9. EIA 568B Ethernet Wiring Standard. In the measurement setup the oscilloscope was set to capture the waveforms: Channel 1-voltage on line 5, Channel 2-current on line 5, Channel 3-voltage on line 4, and Channel 4-current on line 4. The voltage probes were 1010:1 (5 k/50  resistor bridge = 101:1, plus 20 dB attenuator). And the current probes were 20:1 (5 V/A plus 40 dB attenuator). The CDE Controller in all tests was set to 500 V, and depending on the test configuration the Charge Module and DUT may have been grounded. Setup 1 consisted of a short connected to CDE Controller output, one differential pair with one side grounded and pre- connected to the load, and a 100 meter Charge Module using S/UTP cable with the chassis not grounded. The setup and measurement waveforms are shown in Fig 10. From the simplified circuit, after the relay is closed in line 5, we expect a large current flowing from line 5 to line 4 over the differential 100  transmission line structure and the peak current should be 5 A (500 V/100 ). From the waveforms it can be confirmed that the current waveform starts with 5 A peak. Then the waveform shows significant cable loss as the waveforms rapidly decay. After the current reaches the cable ends, reflections occur due to mismatches and several reflections happen until the total signal approaches zero. The voltage is a RC discharge waveform through the voltage measurement path. Fig 10. Simplified schematic and waveforms of CDE calibration setup 1. Setup 2 is similar to setup 1 except the charge module chassis is connected to ground. The setup and measurement waveforms are shown in Fig 11. As can be seen, the current waveforms are the same as the first setup, but the voltage waveform RC
  • 5. time constant is much larger due to the grounding of the Charge Module chassis. Fig. 11. Simplified schematic and waveforms of CDE calibration setup 2. Setup 3 consisted of an open load connected to the CDE Controller output, one differential pair with one side grounded and pre-connected to the load, and a 100 meter Charge Module using S/UTP cable and chassis grounded. The setup and measurement waveforms are shown in Fig 12. There is little displacement current as the load is an open, and the voltage on line 5 is 494 V peak, which is very close to the charge voltage. Fig 12. Simplified schematic and waveforms of CDE calibration setup 3. Setup 4 consisted of a 100  load (with center tap between two 50  resistors grounded) connected to the CDE Controller output, one differential pair with one side grounded and pre- connected to the load, and a 100 meter Charge Module using S/UTP cable and chassis grounded. The setup and measurement waveforms are shown in Fig 13. With the 100  load in place the current waveform magnitude drops to half of that measured with the short as in setups 1 and 2, and there are no reflections. Fig. 13. Simplified schematic and waveforms of CDE calibration setup 4. Except for the shape and magnitude of the measured calibration waveforms, the time delay of the measurement is also important to understand, in particular, which part of the waveform is due to the 100  transmission line extension, and which part is due to the DUT. The waveforms shown in Fig 14 are with the CDE Controller connected to a CAT5E UTP cable only. The current waveform shows the 100  transmission line extension first, then the open end. The real measurement of the DUT starts at the time where the open is shown. Fig 14. CDE Controller with CAT5E UTP cable as only load. E. Test of the CDE System on Ethernet Systems Two 10/100Mbps Ethernet DUTs were tested with the CDE test system as shown in Fig 15. The test parameters are: CDE source voltage of 1 kV, a 100 meter Charge Module using S/UTP cable, and oscilloscope channels are scaled to 1 A/div. The first pin discharge waveform is captured and compared between unit A and unit B. Unit B has a much smaller current
  • 6. peak and higher current duration. This is mainly because the common mode impedance of unit B is much smaller than unit A. Fig. 15. Current measurement of first pin discharge between 2 DUTs. Most systems using the Bob Smith Termination are almost fully charged after the initial discharge, so the current magnitude of the 2nd - 8th discharges are too small compared to the first one. This is not discussed here. Fig 16. CDE test of a charged UTP discharging into a POE system. A Power over Ethernet (POE) system, having more complex termination was also tested. The measurement waveforms are shown in Fig 16. When the first pin contact DUT, first discharge current is generated in common mode through this pin. Then when the other wire in the same twisted pair contacts DUT, another discharge current is generated in differential mode through this pair. Both discharge signals could be transferred from termination to PHY circuit leading to damage in the Ethernet system. IV.CONCLUSION In this article, several important physics for CDEs have been discussed, a general CDE test and measurement solution developed, and some test results with well-defined structures and a few real world Ethernet systems are presented and discussed. The next steps for CDE related test and measurement would be modeling the overall test system with different terminations, and running more tests with Ethernet systems to understand the design principle for CDE. ACKNOWLEDGMENT We would like to thank the EMC Laboratory, Missouri University of Science and Technology for the partnership of CDE related study and research and Cisco for the partnership in CDE related tests and measurements. REFERENCES [1] H. Michael, “Cable Discharge Events”, Part I & II, ESD Open Forum 2009. [2] W. Greason, “Analysis of Cable Discharge Events (CDE),” 2009 Electrostatics Joint Conference [3] S. Wolfgang, B. Tilo, N. Josef, G. Reinhold, M. Kathleen, “Characterization and Simulation of Real-World Cable Discharge Events”, EOS/ESD Symposium 2009 [4] P. Neven, “ESD TRANSFER THROUGH ETHERNET MAGNETICS”, IEEE EMC 2005, pp. 356-363. [5] Texas Instrument, “AN-1511 Cable Discharge Event”. [Online]. Available: http://www.ti.com/lit/an/snla087a/snla087a.pdf .