This document provides an overview of the PVX-4000-2kV integrated high voltage pulser from IXYS Colorado. The key points covered include:
- It is a bipolar 2000V pulse generator designed for capacitive loads with computer control via USB or RS-232.
- It includes internal HV power supplies, air cooling, and rise times under 50ns for loads over 500V and under 100ns for loads under 500V.
- Accessories, applications, pricing, setup instructions, troubleshooting tips, and IXYS's Lab to Launch custom solution program are reviewed.
2. PVX-4000-2kV Webinar Welcome
Introductions
Steve Krausse
James Budai
Recorded Webinar
Can you hear the Audio?
Can you see the video &
presentation?
Chat Function
Questions
Public
Private
support@ixyscolorado.com
sales@ixyscolorado.com
2
3. What We’ll Cover
Product Overview
What’s In The Box?
Accessories & Replacement Parts
Markets
Applications
Price/Availability
Technical Overview
Setting Up
Solutions to Common Problems
Lab to Launch Program
Q&A
3
4. Product Overview 4
Bipolar 2,000V Pulse Generator
Designed for Capacitive Loads
Computer Control USB, RS-232
Internal Trigger
Onboard HV Power Supplies
Designed for both Bench and
Rackmount use
Air Cooled
50 nS tr & tf
RoHS & CE Compliant
5. What’s in the Box?
PVX-4000-2kV Pulsed Voltage Source
High Voltage Output Cable Assembly (DEI# 6100-0131 A00)
Enable Shorting Connector (Pasternack # PE6012)
AC Power Cord
Operating Manual
5
9. Applications 9
Electron Beam Steering
Dielectric Testing and Research
TOF Mass Spectroscopy
Deep Well Measurements
Q-switching
Acoustic Transducers
Microchannel Plates
Photomultiplier Tubes & Image Intensifiers
High Voltage Pulse (>500 V)
10. Pricing & Availability
US MSRP $10,849.18
Outside the US
Taxes
Tariffs
Import Duties
Shipping/Delivery Costs
Etc.
10
Availability
Current: Stock
Normal: Stock to 8-10 Weeks
12. Technical Overview
Designed to drive 2000V into a high impedance capacitive load.
Two internal independent high voltage power supplies
Positive Supply: 0V to +2000V
Negative Supply: 0V to -2000V
Output pulse rise time <50ns with Voutput over 500V into a 344pF Load
Output pulse rise time <100ns with Voutput under 500V into a 344pF Load
12
13. Technical Overview
External Hardware Enable/Disable
Voltage monitor
10V / 1000V output
Computer control
USB
RS232
13
26. Solutions to Common Problems
Problem: Fault LED on or flashing.
Solutions:
1) Make sure the Enable connector is in place.
2) Is the airflow blocked? Overheating?
Problem: Output voltage is below setpoint.
Solutions:
1) Make sure you are operating within the SOA? Remember to account for the cable capacitance
in your load calculation.
26
27. Lab to Launch Program 27
The Lab to Launch program from Directed Energy provides custom OEM
pulsed solutions.
Designed by experts, manufactured in an ISO registered facility, tested and
ready for installation… our modules save you time, effort and cost.
Working together early in development brings our expertise right into your
lab.
Focus on your core product and customer and we’ll provide the solution
for your pulsed and high voltage/high power requirements.
29. Contacting Us
970-493-1901
sales@ixyscolorado.com
Visit Us
1609 Oakridge Drive
Suite 100
Fort Collins, CO 80525
USA
Give us your laser driver problem.
Give us your pulsed voltage problem.
Stay focused on your product and
customer.
The Lab to Launch Program from
Directed Energy…
29