This presentation is about online sensors for sidestream treatment of centrate in wastewater. This is a description of a sensor evaluation performed at Los Angeles County Sanitation District JWPCP during a pilot study of centrate treatment.
2. Acknowledgements
• Sanitation Districts of Los Angeles County
• Robert Morton, Supervising Engineer
• Wastewater Research Section
• JWPCP Laboratory
• YSI, a Xylem brand
• Herb Fancher
• Uli Franke
2
3. Presenters
• Rob Smith
• YSI, a Xylem brand
• Applications Engineer
• Online monitoring
• P.E., BCEE, Ph.D.
• Nick Smal
• Sanitation District of
LA County
• Project Engineer
• P.E.
3
4. Topics
• The problem with centrate nitrogen
• Evolution of sidestream treatment
• Introducing the LA County Sanitation District
JWPCP
• Centrate treatment pilot plant
• Online nitrogen monitoring results
• Summary
4
6. Fate of Nitrogen Removed from Wastewater
For every 1 mil. gal. of water treated:
6
Primary
Settler
Primary Sludge
(30 lbs. N)
Waste Activated Sludge
(140 lbs. N)
330 lbs. N
7. Anaerobic Digestion Releases Captured
Nitrogen
Ammonia is recycled to main-stream in centrate
7
Primary
Settler
Sludge
Thickener
Anaerobic
Digester
Sludge
DewateringCake
N = 300 to 1,000 mg/L
~10% of influent load
8. N x 1
Imported Sludge
Increases the mass of nitrogen in centrate
8
Primary
Settler
Sludge
Thickener
Anaerobic
Digester
Sludge
DewateringCake
9. Imported Sludge
Increases the mass of nitrogen in centrate
9
Primary
Settler
Sludge
Thickener
Anaerobic
Digester
Sludge
DewateringCake
N x 2
10. Imported Sludge
Increases the mass of nitrogen in centrate
10
Primary
Settler
Sludge
Thickener
Anaerobic
Digester
Sludge
DewateringCake
N x 3
11. Solids Pre-Treatment
Increases the mass & concentration of nitrogen in centrate
11
Primary
Settler
Sludge
Thickener
Anaerobic
Digester
Sludge
DewateringCake
N = 1,500 to 3,000 mg/L
13. Why Sidestream Treatment?
• Anaerobic digestion/centrate dewatering
• Medium to Very Large
• Nutrient limits
• Regional solids handling facilities
• Sustainability
Characteristics of utilities with most to gain:
13
30. Pilot System
ANITA Mox / Veolia
• Drum screen - 60 µm mesh panels
• Feed tank (equalization)
• Reactor
• Volume ~ 950 gal
• Media type: AnoxKaldnes K5
(800m2/m3)
• Media Fill: 47%
• Seed Ratio: 100%
31. Pilot System Operation
• Instrumentation and Control
• DO/Aeration
• Feed Flow
• pH
• Temperature
Feed Pump
Reactor
Air Mass Flow
Controller
DO pH
Flow
Meter
Plant Air
Feed Tank
32. Why Online Monitoring
Over a 25% Reduce in weekly laboratory demand
32
Category Parameter Influent Effluent
tCOD W W
sCOD W W
tBOD W W
sBOD W W
TSS D D
VSS D D
TKN W W
NH4-N D D
NO2-N W D
NO3-N W D
PO4-P W --
Alkalinity D D
Biomass -- W
pH D Online
DO -- Online
Temperature -- Online
Others
Organics
Solids
Nitrogen
Category Parameter Influent Effluent
tCOD W Online
sCOD W Online
tBOD W Online
sBOD W Online
TSS D D
VSS D D
TKN W Online
NH4-N D Online
NO2-N W Online
NO3-N W Online
PO4-P W --
Alkalinity D D
Biomass -- W
pH D Online
DO -- Online
Temperature -- Online
Organics
Solids
Nitrogen
Others
91 Samples 65 Samples
33. Ammonium (NH4
+) & nitrate (NO3
-)
Ion selective electrodes (ISE) • Potentiometric (like
pH)
• Requires calibration at
commissioning
(matrix adjustment)
• More potential for drift
33
36. How Nitrogen Measurements Can Be Used
to Better Control the Process
• Ammonia (NH3-N)
• Check of feed rate loop
• Above 200 mg / L– Reduce feed
• Nitrate (NO3-N)
• Check of DO loop
• Above 35 mg / L – Reduce DO
• Nitrite (NO2-N)
• Toxicity / Check of DO loop
• Above 8 mg / L – Depends on NH4 and
NO3 concentrations36
42. Nitrate Monitoring
Not as good as nitrate ISE • Cleaning more
tedious
• No air cleaning
• 28/41 within 20% of
lab photometer
• Online measurement
tended to
underestimate
• Better calibration
needed (more points)
42
45. Bad to Good (with user calibration)
Nitrite UV
45
User calibrationOverestimate
46. Nitrite Monitoring
After user calibration • Most interested in
monitoring nitrite
• Toxicity
concerns
• 12/24 within 20% of
lab photometer
46
47. Why Is It So Difficult to Measure Nitrite?
Overlapping spectra • Lots of wavelengths
required (256)
• High resolution (0.74
nm)
• Compensation for COD
and turbidity important
• Application specific
47
wavelength [nm]
Intensity
49. LA County Take-Aways
• Sensor accuracy satisfactory for the short
duration of the trial.
• Very pleased with the nitrate ISE
• Sensors provided real time observation of the
process – better understanding of dynamics.
• Nitrite toxicity not as critical to process
• Nitrate/ammonium maybe more critical
49
50. YSI Take-Aways
• The human is the most important factor
• Objective
• Puts in time when needed
• Stay close to the customer
• Training
• Configuration
• Intervention
• Data evaluation reveals successes and how
things that could be done better
50