Direct Torque Control of Two Induction Motors Using the
Nine-Switch Inverter
Draoui Abdelghani1
, Allaoua Boumediรจne2
1
Laboratoire de Commande, Analyse et Optimisation des Systรจmes Electro-Energรฉtiques (CAOSEE), UTMB, Algeria
2
Department of Electrical Engineering, University of Tahri Mohammed, Algeria
Article Info ABSTRACT
Article history:
Received Jul 24, 2018
Revised Sep 11, 2018
Accepted Sep 15, 2018
The Nine-Switch Inverter (NSI) is a recently developed dual output
converter. It can be used to drive two three-phase loads independently. As a
substitute to two separate conventional voltage source inverters, the NSI has
been, already, proposed in various industrial applications to reduce the
number of semiconductor switches and its associated energy losses and drive
circuitry. On the other hand, the Direct Torque Control (DTC) is a robust
control scheme of AC motors, which consist of selecting proper state vectors
of a conventional voltage source inverter. The NSI, having a different
working principle from the conventional voltage source inverter and taking
into account the varying influence of active space vectors on motorโ€™s torque
and stator flux, a Direct Torque Control is suggested in this paper to,
efficiently, drive two induction motors independently, while minimizing the
torque and stator flux ripples of both motors. Simulations results confirm the
effectiveness of the proposed algorithm. In addition, application of this
newly proposed control scheme in operation of an Electric Vehicule (EV) is
demonstrated.
Keyword:
DTC
Induction motor
SVM
EV
Copyright ยฉ 2018 Institute of Advanced Engineering and Science.
All rights reserved.
Corresponding Author:
Draoui Abdelghani,
Department of Electrical Engineering,
CAOSEE Laboratory, University of Tahri Mohamed, Bechar, Algeria,
University of Tahri Mohamed, Bechar, B.P 417 Bechar 08000, Algeria.
Email: draoui.abdelghani@gmail.com
1. INTRODUCTION
One of the developmental trends, followed by researchers in the field of power electronics,
nowadays, is to come up with new converter topologies with a reduced number of semiconductor switches
[1]-[3]. These switches represent the most expensive parts of the converter and are responsible, to a large
extent, for the energy losses due to the switching operation. For example, as a substitute of the dual inverter,
which consists of two separate two-level inverters connected in parallel, several new topologies has been
developed, namely, the B4 inverter [4], the Five Leg Inverter [5] and the Nine Switch Inverter(NSI) [6].
Having the least number of semiconductor switches as compared to the aforementioned inverter topologies,
the NSI has been suggested in various industrial applications [7]-[11]. Due to its special working mechanism,
this inverter has raised a new challenge, which is the adaptation of the classical control methods developed
based on the conventional inverter topologies [12]-[14]. In essence, In order to ensure the independent
control of the two NSI loads, this inverter can only supply one of its two loads, at any given instant.
The NSI has been, also, suggested in a DTC control scheme for driving two induction motors [15].
This suggested DTC control scheme consist of controlling the two loads in alternate manner with equal time
of supply of both loads. Although this proposed control scheme resulted in a relatively good performance, the
varying properties of the inverterโ€™s state vectors with the operating condions, will lead to high torque and
stator flux ripples, as stated in [16],[17]. As a remedy to this problem, the torque and stator flux errors of
Int J Pow Elec & Dri Syst ISSN: 2088-8694 ๏ฒ
Direct Torque Control of Two Induction Motors Using the Nine-Switch Inverter (Draoui Abdelghani)
1553
each motor are calculated and the influence of the NSI space vectors on each motorโ€™s torque and stator flux is
estimated to select the motor to be supplied, next. The advantage of the newly proposed DTC scheme over
the older DTC control scheme will be relevant, when the two motors are operating in different speeds and
loading conditions.
In this paper, a new algorithm for a DTC control scheme is suggested, based on selection of the
most appropriate inverter state vector. This paper is organized as follows. Section 2 describes the working
principle of the Nine-Switch Inverter. Section 3 explains, briefly, the DTC of the induction motor. Section 4
details the analytical studies revealing the properties of active vectors in the different operating conditions.
The proposed algorithm for driving two induction motors fed by the NSI will be detailed in Section 5.
Section 6 presents results and discussion.
2. THE NINE SWITCH INVERTER
The NSI has three lesser switches as compared to the classical dual output inverter, it has been
developed by replacing the middle six switches of the classical dual output Inverter by only three switches,
both inverters are shown in Figure 1.
Figure 1. (a) The classical Dual output inverter (b) The NSI
The NSI can be viewed as two two-level inverters operating in alternate manner, the upper six
switches constitute a classical six switch VSI, in the other hand, the six lower switches, also, constitute
another six switch VSI, hence, the middle three switches are shared between the two sub-inverters.
Originally, authors applied the Sinusoidal PWM control scheme, for each leg, the gate signal of the upper
switch is generated by comparing the upper half of a triangular carrier signal with a sinusoidal reference
signal. The gate signal of the lower switch is generated by comparing the lower half of the same triangular
carrier signal with another sinusoidal reference signal. In order to avoid closing the three switches of the
same leg simultaneously and therefore shorting the DC source, the gate signal of the middle switch is
generated by the output of a XOR logic gate whose inputs are the two gate signals for the upper and lower
switches, Figure 2 shows generated gate signals from a carrier signal and two reference signals.
๏ฒ ISSN: 2088-8694
Int J Pow Elec & Dri Syst, Vol. 9, No. 4, December 2018 : 1552 โ€“ 1564
1554
Figure 2. carrier signal, references signals and gate signals of the NSI using SPWM: (a) carrier signal and
references signals of upper and lower switches. (b) gate signal of the upper switch reference (c)gate signal of
the lower gate signal, (d) gate signal of the middle signal
Each of the three legs of the NSI , is composed of a three switches and only one switch is allowed to
be open, at time, in each leg, to avoid : 1- supplying two loads at the same time which will lead to loss of
independency of control. 2- keeping terminals of any of the two motors open-circuited, therefore, a
combination of 27 switching states are allowed in the control of the Nine Switch Inverter [18].
If two Y-connected loads are to be driven by the NSI, the peak fundamental phase voltage of each
load is given as follows:
Vanpeak(i) =
mi.Vin
2
(1)
To operate in the linear modulation region of the SPWM, the two reference signals are constrained
to stay within the horizontal band of the carrier signal without overlapping, therefore the following inequality
has to be, always, satisfied:
๐‘š1 + ๐‘š2 โ‰ค 1 (2)
The reference signals of the ith
load has the following form:
๐‘‰๐‘Ÿ๐‘’๐‘“๐‘–
= ๐ด๐‘–. sin(2๐œ‹. ๐‘“๐‘–) + ๐‘œ๐‘“๐‘“๐‘ ๐‘’๐‘ก๐‘– (3)
By manipulating amplitudes and offsets of both sinusoidal reference signals within the carrier signal
band, the percentage of use of the DC source is divided accordingly between the two loads. When applying
Space Vector Modulation [18], as it is the case of DTC control, a gain of 15% in the sum of modulation
indices, which translate to higher torque production, hence, the inequality condition in equation 2 becomes :
๐‘š1 + ๐‘š2 โ‰ค
2
โˆš3
(4)
3. DIRECT TORQUE CONTROL
3.1. Direct Torque Control Technique
The Direct Torque Control (DTC) has been introduced in the second half of the 1980s [19],[20],
although a relatively new control strategy, DTC has quickly gained industrial acceptance [21]. In the
conventional DTC scheme, the stator flux and the electromagnetic torque are controlled by proper selection
of inverter states vectors.
For proper operation of DTC control scheme, an accurate model for the induction motor is required,
since stator flux and the electromagnetic torque are estimated, based the motor model. The two-phase
dynamic model of IM in the stationary dq frame:
๐‘‰๐‘ ๐‘‘๐‘ž = ๐‘…๐‘ ๐‘–๐‘ ๐‘‘๐‘ž +
๐‘‘
๐‘‘๐‘ก
(๐œ“๐‘ ๐‘‘๐‘ž)
๐‘‰๐‘Ÿ๐‘‘๐‘ž = 0 = ๐‘…โ€ฒ๐‘Ÿ๐‘–๐‘Ÿ๐‘‘๐‘ž +
๐‘‘
๐‘‘๐‘ก
(๐œ“๐‘Ÿ๐‘‘๐‘ž) โˆ’ ๐‘—๐‘ค๐‘Ÿ๐œ“๐‘Ÿ๐‘‘๐‘ž
๐œ“๐‘ ๐‘‘๐‘ž = ๐ฟ๐‘ ๐‘–๐‘ ๐‘‘๐‘ž + ๐ฟ๐‘š๐‘–๐‘Ÿ๐‘‘๐‘ž
๐œ“๐‘Ÿ๐‘‘๐‘ž = ๐ฟ๐‘š๐‘–๐‘ ๐‘‘๐‘ž + ๐ฟโ€ฒ๐‘Ÿ๐‘–๐‘Ÿ๐‘‘๐‘ž (5)
Derivative of stator flux is equal to the stator EMF, hence, stator flux magnitude strongly depends on stator
voltage.
๐‘‘
๐‘‘๐‘ก
(๐œ“๐‘ ๐‘‘๐‘ž) = ๐‘’๐‘‘๐‘ž = ๐‘‰๐‘ ๐‘‘๐‘ž โˆ’ ๐‘…๐‘ ๐‘–๐‘ ๐‘‘๐‘ž (6)
If voltage drop across Rs is ignored, stator flux can be controlled by stator voltage applied:
โˆ†๐œ“๐‘ ๐‘‘๐‘ž = (๐‘‰๐‘ ๐‘‘๐‘ž)โˆ†๐‘ก (7)
Int J Pow Elec & Dri Syst ISSN: 2088-8694 ๏ฒ
Direct Torque Control of Two Induction Motors Using the Nine-Switch Inverter (Draoui Abdelghani)
1555
The developed torque is proportional to the sine of angle between stator and rotor flux vectors ฮธsr
๐‘‡๐‘’
โƒ—โƒ—โƒ— =
3
2
๐‘ƒ
2
๐ฟ๐‘š
๐œŽ๐ฟ๐‘ ๐ฟโ€ฒ๐‘Ÿ
๐œ“๐‘Ÿ
โƒ—โƒ—โƒ—โƒ— โŠ— ๐œ“๐‘†
โƒ—โƒ—โƒ—โƒ— (8)
|๐‘‡๐‘’| =
3
2
๐‘ƒ
2
๐ฟ๐‘š
๐œŽ๐ฟ๐‘ ๐ฟโ€ฒ๐‘Ÿ
|๐๐’“||๐๐‘บ| sin ๐œƒ๐‘ ๐‘Ÿ (9)
Angle of ฯˆS
โƒ—โƒ—โƒ—โƒ—โƒ—โƒ— is also dependent on stator voltage, hence, |Te| can also be controlled by applying the
proper vector to change ฮธsr.
3.2. DTC speed mode control scheme
The DTC control scheme has two modes of operation, the DTC torque mode where motor torque is
controlled directly and the DTC speed mode where motor torque is controlled via motor speed. The DTC
speed mode control scheme is shown in Figure 3.
Figure 3. The DTC speed mode control scheme
In the DTC speed mode control scheme, three phase stator currents, stator voltages are measured,
motor speed is estimated or measured using an encoder. Stator flux magnitude and angle are estimated from
the obtained currents and voltages.
Measured or estimated speed and measured stator flux amplitude are compared with their respective
reference values. The stator flux error is fed directly to a hysteresis controller, where the motor speed error is
fed to a PI controller then the output of this latter is fed to another hysteresis controller. The output of
hysteresis controllers along with the stator flux angle will yield the proper vector to supply according to a
predefined switching table.
3.3. Adaptation of DTC control scheme for use with the NSI
For an independent control of the two loads, the NSI can only supply one of its two loads at a time,
when one load is supplied, the phases of the second load are short-circuited through one of the DC rails. In a
DTC point of view, when an active state vector is applied to the inverter composed of the upper six switches,
a zero vector is applied to the inverter composed of the six lower switches. While the effect of an active
vector on stator flux and torque depends on stator flux space vector position, the zero vector has little effect
on flux but it will reduce the torque [22]. This property justify the priority of controlling the torque over the
control of stator flux in the proposed algorithm.
In [15], authors suggested a DTC control scheme for two induction motors fed by the NSI as shown
in Figure 4, where the two motors are fed in alternate manner with equal time of supply, however, analytical
studies performed by [23], show that the rate of increase and the rate of decrease in both torque and stator
flux values are not equal for every two successive switchings and therefore controlling the two motors in
๏ฒ ISSN: 2088-8694
Int J Pow Elec & Dri Syst, Vol. 9, No. 4, December 2018 : 1552 โ€“ 1564
1556
alternate manner with 50% duty cycle, does not, necessarily, guarantee optimal results, as it will cause
asymmetry and high ripples.
Figure 4. The proposed DTC control scheme in [15] using the NSI
The control scheme proposed by authors is very similar to the conventional control scheme shown in
Figure 3, the only difference is that when a variable SA, SB and SC are assigned by the switching Table 1 the
synchronization block set all variable SX, SY and SZ to zero for 50% of the sampling time, for the other half
of the sampling time SA, SB and SC are set to one while SX, SY and SZ are assigned by the switching Table 2.
4. TORQUE AND STATOR FLUX RATES OF CHANGE
4.1. Rate of change in motor torque
In the conventional switching selection method [23], the increase and decrease in torque rates vary
with the speed of motor,
โˆ†๐‘‡๐‘’ โ†‘= [๐‘ƒ(๐œ“๐‘Ÿ
โƒ—โƒ—โƒ—โƒ— โŠ— ๐‘ฃ๐‘†
โƒ—โƒ—โƒ— ) โˆ’ ๐‘ƒ๐‘ค๐‘Ÿ๐œ“๐‘ 
โƒ—โƒ—โƒ—โƒ— ยฐ ๐œ“๐‘Ÿ
โƒ—โƒ—โƒ—โƒ— โˆ’ ๐‘…๐‘š๐‘‡๐‘’]๐‘‡๐‘“/๐ฟฯƒ (10)
โˆ†๐‘‡๐‘’ โ†“= [โˆ’๐‘ƒ๐‘ค๐‘Ÿ๐œ“๐‘ 
โƒ—โƒ—โƒ—โƒ— ยฐ ๐œ“๐‘Ÿ
โƒ—โƒ—โƒ—โƒ— โˆ’ ๐‘…๐‘š๐‘‡๐‘’]๐‘‡๐‘“/๐ฟฯƒ (11)
Where Tf is the sampling period, โŠ— stands for vector product while ยฐ denotes the scalar product and ๐‘…๐‘š =
(๐ฟ๐‘Ÿ๐‘…๐‘  + ๐ฟ๐‘ ๐‘…๐‘Ÿ)/ ๐ฟ๐‘š ; ๐ฟฯƒ = (๐ฟ๐‘ ๐ฟ๐‘Ÿ โˆ’ ๐ฟ๐‘š
2
)/๐ฟ๐‘š
The analysis can be summarized in the Table 1.
Table 1. Increase and decrease rates in Torque Vs Motor Speed [23]
Low speed region Medium speed region High Speed Region
Increase Vs Decrease in
Torque
|โˆ†Teโ†‘| >|โˆ†Teโ†“| |โˆ†Teโ†‘| โ‰ˆ |โˆ†Teโ†“| |โˆ†Teโ†‘| <|โˆ†Teโ†“|
The asymmetry of torque ripple in the various speed regions, are shown in figures from the
experiments conducted by the same authors [23]. From the Table 1 and Figure 5, we can clearly notice that
driving the two loads with different speeds, will result in higher and asymmetrical torque errors, therefore,
supplying the two motors in alternate manner with an equal time of application will worsen the situation. The
proposed algorithm will supply the motor with the higher torque error.
Int J Pow Elec & Dri Syst ISSN: 2088-8694 ๏ฒ
Direct Torque Control of Two Induction Motors Using the Nine-Switch Inverter (Draoui Abdelghani)
1557
(a)
(b)
(c)
Figure 5 . Torque ripples in (a) Low Speed Region (b) Medium Speed Region (c) High Speed Region [23]
4.2. Rate of change in stator flux:
Given that the angle ฮธ (ฮธ ฯต [-30ยฐ to 30ยฐ]) which is defined as the angle between stator flux space
vector ฯ† and the active vector Vk, the effect of the applied active vectors Vk+1 and Vk+2 on stator flux are
demonstrated in the Table 2 [23]. From the Table 2 and as illustrated in Figure 6, it is evident that selection
of vectors near the borders of the sectors will lead to a unbalanced change in stator flux error, which require
immediate selection of several active vectors to compensate for the change, therefore, supplying two motors
in an alternate fashion with an equal time of application will not help in restoring stator flux to its tolerable
values.
Table 2. Influence of vector Vs Stator flux space vector location
ฮธ โ‰ˆ - 30ยฐ ฮธ โ‰ˆ 30ยฐ
Vk+1 applied small increase large decrease
Vk+2 applied large increase small decrease
๏ฒ ISSN: 2088-8694
Int J Pow Elec & Dri Syst, Vol. 9, No. 4, December 2018 : 1552 โ€“ 1564
1558
Figure 6. Influence of vector Vs Stator flux space vector location
In the DTC control scheme, in the low speed region, the stator flux ripples are unacceptably high
[23]. Findings summarized in Table 2 can be exploited to reduce ripples by selecting the load whose vector
have the moderate effect on the stator flux. In other words, the load whose vector is closer to the center of the
sector being selected.
5. THE PROPOSED ALGORITHM
In order to reduce ripples of the electromagnetic torque and the stator flux in both motors and to
ensure a relatively higher switching frequency, the aforementioned facts, are exploited to develop a new
control scheme based on the following algorithm (Figure 7):
Figure 7. The Flow chart of the developed algorithm
For the reasons stated earlier, control of torque has been given higher priority over the control of
stator flux. If any one of the motors or both are having a high torque error, the load with the higher torque
error will be supplied by the inverter, in the other hand, if the torque errors of both loads, are acceptable, the
Int J Pow Elec & Dri Syst ISSN: 2088-8694 ๏ฒ
Direct Torque Control of Two Induction Motors Using the Nine-Switch Inverter (Draoui Abdelghani)
1559
load whose vector have the least influence on the stator flux change will be selected, in case of operation in
the low speed region. Otherwise, the selection is performed in an alternate manner.
Figure 8. Simulinkยฎ
Block diagram of the entire System
Figure 9. Synchronization Block and Matlabยฎ
Function File
๏ฒ ISSN: 2088-8694
Int J Pow Elec & Dri Syst, Vol. 9, No. 4, December 2018 : 1552 โ€“ 1564
1560
6. RESULTS AND DISSCUSION
In order to demonstrate the indpendent control of both motors and to investigate the validity of the
proposed algorithm, Simulation using the Matlab/Simulinkยฎ
software is carried out. Two induction motors
are driven with different combinations of speed profiles (120, 300 rad/s), while applying a nominal torque
load (26 N.m) in each speed combination, the stator flux of both motor is set to 0.9 Wb.
In the low speed region, the stator flux of each motor has high ripples, this is one of the drawbacks
of the original DTC control scheme. the significant voltage drop in stator resistance leads to a poor estimation
of stator flux values, hence, a wrong state vector is applied. Several works [24]-[26] has been proposed to
have a better estimate of stator flux value. In our proposed control scheme, the algorithm will supply the
motor whose active vector has the moderate influence to mitigate the sharp increase of stator flux. Stator flux
of the two motors in shown in Figure 10.
(a)
(b)
Figure 10. Stator Flux magnitude of: (a) Motor 1. (b) Motor 2
At first, the speed of the two motors is set to 120 rad/sec in a time interval of 200 milliseconds, due
to this high acceleration rate, 120% of the nominal torque command is requested by the control system, to
reach the assigned speed in time. At time 0.4 seconds, a nominal load is coupled to both motors, the motors
torques are increased to keep both motors running at the assigned speed, a slight decrease is noticed (i.e a
steady state error < 1% of the nominal speed). In the medium speed region, the algorithm will control the NSI
to supply the load with the larger torque error, Figure 11 and Figure 12 show acceptable torque ripples.
Int J Pow Elec & Dri Syst ISSN: 2088-8694 ๏ฒ
Direct Torque Control of Two Induction Motors Using the Nine-Switch Inverter (Draoui Abdelghani)
1561
Figure 11. Motor 1 Torque Vs its reference value
Figure 12. Motor 2 Torque Vs its reference value
After driving both loads with a medium speed, the speed of the first load is increased up to 300
rad/sec while the second load is kept running at a medium speed, once again, 120% of the nominal is
produced at the first load to accelerate. a nominal load is applied afterward, Figures 11 and 12 show that the
torque ripples of the first load are slightly larger than those of the second load due to the difference in speeds.
On the other hand, less than 1% of steady state error is noticed in speeds of both loads. As stated earlier,
based on remarks from Table 1, the torque ripples of the first motor would be higher, if the older control
scheme is used.
The speed of the second load is increased to the nominal speed (300 rad/sec) at time 2.0 seconds, a
120% of nominal torque command is applied to accelerate, a nominal load is applied to both motors, ripples
in both stator flux and torque of each motor remains whithin limits, which ensures a good regulation of speed
of both motors as shown, in Figures 13 and 14.
๏ฒ ISSN: 2088-8694
Int J Pow Elec & Dri Syst, Vol. 9, No. 4, December 2018 : 1552 โ€“ 1564
1562
Figure 13. Motor 1 speed Vs its reference value
Figure 14. Motor 1 speed Vs its reference value
In the DTC speed mode, the speed of both motors are controlled instead of torques, this facts justify
the abrupt rise in torque when acceleration of any of the two motors is requested. A saturation unit is used in
the control scheme to avoid forcing the two motors to develop more than 120% of their nominal torque, In
practice, an anti-windup unit is added to the PI controller to compensate for the overshoot inherent in Integral
part of the controller [27],[28].
The advantage of the present DTC control scheme over the old DTC control scheme, is evident in
two instances, 1- when the two motors are loaded and running at low speeds, inaccurate estimation of stator
flux may occur and the alternate selection of active state vectors for the two motors will worsen the
performance as it would lead to an abrupt change in stator flux which require application of several active
vectors to re-establish stator flux to permissible values. 2- If the old DTC control is opted for, when one of
the motors is running at low speed and the other motor is running at high speed, the rate of decrease of torque
in the latter motor will be more significant, eventually, leading to abrupt decrease in its speed and a slow
response of this motor to reach the assigned speed.
The NSI has been already proposed in Hybrid Electric Vehicle (HEV) [29], similarly, a
comprehensive literature review of the DTC control scheme and its application in EV field is detailed in [30]
and as demonstrated in the present paper, the combination of DTC control with the use NSI makes it well
suited for use in Electric Vehicle EV and HEV applications. The use of the NSI as a substitute to two
separate two-level inverters, as shown in Figure 15, will help reduce the overall cost and energy consumption
of EVs.
Int J Pow Elec & Dri Syst ISSN: 2088-8694 ๏ฒ
Direct Torque Control of Two Induction Motors Using the Nine-Switch Inverter (Draoui Abdelghani)
1563
(a) (b)
Figure 14. Topology of: (a) Conventional EV (b) Suggested EV
7. CONCLUSION
In this paper, a new Direct Torque control has been developed to drive two induction motors,
independently, via the Nine-Switch Inverter. Simulation results show acceptable torque and stator flux
ripples for each motor, in different speed profiles. Further improvements can be made, by using the a motor
model which takes into account the iron core losses and optimal results can be obtained when more advanced
stator flux estimators are used. Being effective in driving two motors with different speed, the NSI has been
proved to be well suited for EVs applications.
REFERENCES
[1] Thiyagarajan V. and Somasundaram P., โ€œA New Level Symmertrical Inverter with Reduced Switch Count,โ€
International Journal of Power Electronics and Drive Systems, vol/issue: 9(2) pp. 921-925, 2018.
[2] F. Chouaf and S. Saad, โ€œA New Structure of the Nine Level Inverter Used as Active Power Filter with a Reduced
Number of Swiches,โ€ International Journal of Power Electronics and Drive Systems, vol/issue: 9(1), pp. 198-209,
2017.
[3] T. Muhammad, et al., โ€œCascaded Symmetric Multilevel Inverter with Ruduced Number of Controlled Switches,โ€
International Journal of Power Electronics and Drive Systems, vol/issue: 8(2), pp. 795-803, 2017.
[4] F. Blaabjerg, et al., โ€œA new optimized space-vector modulation strategy for a component-minimized voltage source
inverter,โ€ IEEE Trans. PowerElectron., vol/issue: 12(4), pp. 704โ€“714, 1997.
[5] M. Jones, et al., โ€œFive-leg inverter PWM technique for reduced switch count two-motor constant power
applications,โ€ IET Electr. Power Appl., vol/issue: 2(5), pp. 275โ€“287, 2008.
[6] T. Kominami and Y. Fujimoto, โ€œA novel nine-switch inverter for independent control of two three-phase loads,โ€
Conf. Rec. IEEE IAS Annu.Meeting, pp. 2346โ€“2350, 2007.
[7] M. Heydari, et al., โ€œA Novel Variable-Speed Wind Energy System Using Permanent-Magnet Synchronous
Generator and Nine-Switch AC/AC Converter,โ€ 1st Power Electronic & Drive System Technologies Conference
(PEDSTC), Tehran, Iran, pp. 5-9, 2010.
[8] C. Liu, et al., โ€œA Novel Three-phase Three-leg AC/AC Converter Using Nine IGBTs,โ€ IEEE Transaction on Power
Electronic, vol/issue: 24(5), pp. 1151-1160, 2009.
[9] L. R. Limongi, et al., โ€œDual hybrid power filter based on a nine-switch inverter,โ€ Elsevier Electric Power Systems
Research, vol. 117, pp. 154-162, 2014.
[10] M. S. Diab, et al., โ€œA nine-switch-converter-based integrated motor drive and battery charger system for EVs using
symmetrical six-phase machines,โ€ IEEE Trans. Ind. Electron., vol/issue: 63(9), pp. 5326-5335, 2016.
[11] C. A. Reusser, โ€œFull-electric ship propulsion based on a dual nine-switch inverter topology for dual three-phase
induction motor drive,โ€ 2016 IEEE Transportation Electrification Conference and Expo (ITEC), pp. 1-6, 2016.
[12] D. Abdelghani and A. Boumรฉdiene, โ€œSpace Vector Modulation of Quasi-Z Source and Nine-Switch Inverter,โ€
Electrotehnica, Electronica, Automatica (EEA), vol/issue: 66(1), pp. 80-86, 2018.
[13] F. Gao, et al., โ€œOptimal pulsewidth modulation of nine-switch converter,โ€ Power Electronics, IEEE Transactions
on, vol/issue: 25(9), pp. 2331โ€“2343, 2010.
[14] X. Li, et al., โ€œNew PWM strategy for nine-switch inverters with minimum number of semiconductor switching,โ€
2014 International Power Electronics and Application Conference and Exposition, pp. 406-410, 2014.
[15] M. Abbache, et al., โ€œDirect torque control of nine switches inverter-dual induction motors,โ€ Conf. Rec. IEEE MED,
pp. 810โ€“815, 2014.
[16] J. W. Kang and S. K. Sul, โ€œAnalysis and prediction of inverter switching frequency in direct torque control of
induction machine based on hysteresis bands and machine parameters,โ€ IEEE Trans. Ind. Electron., vol.
48, pp. 545โ€“553, 2001.
[17] Casadei D., et al., โ€œAnalytical investigation of torque and flux ripple in DTC schemes for induction motors,โ€ 23rd
International conference on industrial electronics, control and instrumentation (IECON 97), vol. 2, pp. 552โ€“6,
1997.
[18] S. M. Dehghan, et al., โ€œSpace vectors modulation for nine-switch converters,โ€ IEEE Trans. Power Electron., vol.
25, pp. 1488โ€“1496, 2010.
[19] I. Takahashi and T. Noguchi, โ€œA new quick-response and high-efficiency control strategy of an
induction motor,โ€ IEEE Trans. Ind. Appl, IA, vol/issue: 22(5), pp. 820โ€“827, 1986.
๏ฒ ISSN: 2088-8694
Int J Pow Elec & Dri Syst, Vol. 9, No. 4, December 2018 : 1552 โ€“ 1564
1564
[20] M. Depenbrock, โ€œDirect self-control (DSC) of inverter-fed induction motors,โ€ IEEE Trans. Power Elect., vol/issue:
3(4), pp. 420โ€“429, 1988.
[21] P. Tiitinen, et al., โ€œThe next generation motor control method: Direct torque control (DTC),โ€ Europ. Power Elect.
J., vol/issue: 5(1), pp. 14โ€“18, 1995.
[22] N. R. N. Idris and A. H. M. Yatim, โ€œDirect torque control of induction machines with constant switching frequency
and reduced torque ripple,โ€ IEEE Trans. Ind. Electron., vol/issue: 51(4), pp. 758-767, 2004.
[23] J. Chen and Y. Li, โ€œVirtual vectors based predictive control of torque and flux of induction motor and speed
sensorless drives,โ€ Conf. Rec. IEEE-IAS Annu. Meeting, pp. 2606โ€“2613, 1999.
[24] I. Alsofyani and N. Idris, โ€œSimple Flux Regulation for Improving State Estimation at Very Low and Zero Speed of
a Speed Sensorless Direct Torque Control of an Induction Motor,โ€ IEEE Transactions on Power Electronics,
vol/issue: 31(4), pp. 3027-3035, 2016.
[25] Y. A. Alamri, et al., โ€œImproved Stator Flux Estimation for Direct Torque Control of Induction Motor Drives,โ€
International Journal of Power Electronics and Drive Systems, vol/issue: 7(4), pp. 1049-1060, 2016.
[26] I. Alsofyani and N. R. N. Idris, โ€œLookup-Table-Based DTC of Induction Machines With Improved Flux Regulation
and Extended Kalman Filter State Estimator at Low-Speed Operation,โ€ IEEE Transactions on Industrial
Informatics, vol/issue: 12(4), pp. 1412-1425, 2016.
[27] M. J. Li and L. Q. Meng, โ€œA New Anti-Windup PI Controller for Direct Torque Control System,โ€ TELKOMNIKA
Indonesian Journal of Electrical Engineering, vol/issue: 12(7), pp. 5268- 5274, 2014.
[28] F. C. Ferreira, et al., โ€œAnti wind-up techniques applied to real tank level system performed by PI controllers,โ€ 20th
International Conference on SystemTheory, Control and Computing (ICSTCC), pp. 263โ€“268, 2016.
[29] M. Dehghan, et al., โ€œHybrid ElectricVehicle based on Bidirectional Z-Source Nine-Switch Inverter,โ€ IEEE
Transactions on Vehicular Technology, vol/issue: 59(6), pp. 2641-2653, 2010.
[30] T. Sutikno, et al., โ€œA review of direct torque control of induction motors for sustainable reliability and energy
efficient drives,โ€ Renew Sustain Energy Rev., vol. 32, pp. 548โ€“58, 2014.
NUMENCLATURE
Lโ€™r : Rotor Inductance refered to the stator
Rโ€™r : Rotor Resistance refered to the stator
Rs : Stator Resistance
Ls : Stator Inductance
LM : Mutual Inductance
๐›น
โƒ—โƒ— s : Stator Flux Space Vector
๐›น
โƒ—โƒ— r : Stator Flux Space Vector
ฯƒ : Leakage coefficient.
Parameters of simulated motors:
Line to Line Voltage : 400 V
Number of pole pairs : 2 poles
Stator resistance : 1.37 ฮฉ
Stator inductance : 0.1459 H
Rotor resistance : 1.1 ฮฉ
Rotor inductance : 0.149 H
Mutual inductance : 0.141 H
Moment of Inertia : 0.1 Kg/m2

More Related Content

What's hot

Constant Frequency Torque Controller for DTC with Multilevel Inverter of Indu...
Constant Frequency Torque Controller for DTC with Multilevel Inverter of Indu...Constant Frequency Torque Controller for DTC with Multilevel Inverter of Indu...
Constant Frequency Torque Controller for DTC with Multilevel Inverter of Indu...IJPEDS-IAES
ย 
L021201085091
L021201085091L021201085091
L021201085091theijes
ย 
Voltage recovery of induction generator using indirect torque control method
Voltage recovery of induction generator using indirect torque control methodVoltage recovery of induction generator using indirect torque control method
Voltage recovery of induction generator using indirect torque control methodiaemedu
ย 
Ep4301856861
Ep4301856861Ep4301856861
Ep4301856861IJERA Editor
ย 
Fuzzy-PI Torque and Flux Controllers for DTC with Multilevel Inverter of Indu...
Fuzzy-PI Torque and Flux Controllers for DTC with Multilevel Inverter of Indu...Fuzzy-PI Torque and Flux Controllers for DTC with Multilevel Inverter of Indu...
Fuzzy-PI Torque and Flux Controllers for DTC with Multilevel Inverter of Indu...IJPEDS-IAES
ย 
Comparison of Multi-Machine Transient Stability Limit Using UPFC
Comparison of Multi-Machine Transient Stability Limit Using UPFCComparison of Multi-Machine Transient Stability Limit Using UPFC
Comparison of Multi-Machine Transient Stability Limit Using UPFCIJMTST Journal
ย 
Speed Control System for BLDC Motor by using Direct Back EMF Detection Mathod
Speed Control System for BLDC Motor by using Direct Back EMF Detection MathodSpeed Control System for BLDC Motor by using Direct Back EMF Detection Mathod
Speed Control System for BLDC Motor by using Direct Back EMF Detection Mathodijtsrd
ย 
Multi-machine system with Series FACTS device: Static synchronous series comp...
Multi-machine system with Series FACTS device: Static synchronous series comp...Multi-machine system with Series FACTS device: Static synchronous series comp...
Multi-machine system with Series FACTS device: Static synchronous series comp...IRJET Journal
ย 
Total Harmonic Distortion Analysis of a Four Switch 3-Phase Inverter Fed Spee...
Total Harmonic Distortion Analysis of a Four Switch 3-Phase Inverter Fed Spee...Total Harmonic Distortion Analysis of a Four Switch 3-Phase Inverter Fed Spee...
Total Harmonic Distortion Analysis of a Four Switch 3-Phase Inverter Fed Spee...IJPEDS-IAES
ย 
Modeling and performance analysis of a small scale direct driven pmsg based w...
Modeling and performance analysis of a small scale direct driven pmsg based w...Modeling and performance analysis of a small scale direct driven pmsg based w...
Modeling and performance analysis of a small scale direct driven pmsg based w...Alexander Decker
ย 
Direct Torque Control of Induction Motor Drive Fed from a Photovoltaic Multil...
Direct Torque Control of Induction Motor Drive Fed from a Photovoltaic Multil...Direct Torque Control of Induction Motor Drive Fed from a Photovoltaic Multil...
Direct Torque Control of Induction Motor Drive Fed from a Photovoltaic Multil...IJERA Editor
ย 
Anees ppt on hcc
Anees ppt on hccAnees ppt on hcc
Anees ppt on hccanees ansari
ย 
Master slave vector controlled double induction
Master slave vector controlled double inductionMaster slave vector controlled double induction
Master slave vector controlled double inductioneSAT Publishing House
ย 
Master slave vector controlled double induction motor using unity power facto...
Master slave vector controlled double induction motor using unity power facto...Master slave vector controlled double induction motor using unity power facto...
Master slave vector controlled double induction motor using unity power facto...eSAT Journals
ย 
Analysis of wind turbine driven permanent magnet synchronous generator under ...
Analysis of wind turbine driven permanent magnet synchronous generator under ...Analysis of wind turbine driven permanent magnet synchronous generator under ...
Analysis of wind turbine driven permanent magnet synchronous generator under ...Alexander Decker
ย 
Direct Torque Control of Four Switch Three Phase Inverter Fed Induction Motor...
Direct Torque Control of Four Switch Three Phase Inverter Fed Induction Motor...Direct Torque Control of Four Switch Three Phase Inverter Fed Induction Motor...
Direct Torque Control of Four Switch Three Phase Inverter Fed Induction Motor...IAES-IJPEDS
ย 
Carrier based hybrid pwm algorithm with reduced common mode voltage
Carrier based hybrid pwm algorithm with reduced common mode voltageCarrier based hybrid pwm algorithm with reduced common mode voltage
Carrier based hybrid pwm algorithm with reduced common mode voltageIAEME Publication
ย 
PARAMETER IDENTIFICATION AND MODELLING OF SEPARATELY EXCITED DC MOTOR
PARAMETER IDENTIFICATION AND MODELLING OF SEPARATELY EXCITED DC MOTOR PARAMETER IDENTIFICATION AND MODELLING OF SEPARATELY EXCITED DC MOTOR
PARAMETER IDENTIFICATION AND MODELLING OF SEPARATELY EXCITED DC MOTOR ijiert bestjournal
ย 

What's hot (20)

Constant Frequency Torque Controller for DTC with Multilevel Inverter of Indu...
Constant Frequency Torque Controller for DTC with Multilevel Inverter of Indu...Constant Frequency Torque Controller for DTC with Multilevel Inverter of Indu...
Constant Frequency Torque Controller for DTC with Multilevel Inverter of Indu...
ย 
L021201085091
L021201085091L021201085091
L021201085091
ย 
Voltage recovery of induction generator using indirect torque control method
Voltage recovery of induction generator using indirect torque control methodVoltage recovery of induction generator using indirect torque control method
Voltage recovery of induction generator using indirect torque control method
ย 
Ep4301856861
Ep4301856861Ep4301856861
Ep4301856861
ย 
Fuzzy-PI Torque and Flux Controllers for DTC with Multilevel Inverter of Indu...
Fuzzy-PI Torque and Flux Controllers for DTC with Multilevel Inverter of Indu...Fuzzy-PI Torque and Flux Controllers for DTC with Multilevel Inverter of Indu...
Fuzzy-PI Torque and Flux Controllers for DTC with Multilevel Inverter of Indu...
ย 
Comparison of Multi-Machine Transient Stability Limit Using UPFC
Comparison of Multi-Machine Transient Stability Limit Using UPFCComparison of Multi-Machine Transient Stability Limit Using UPFC
Comparison of Multi-Machine Transient Stability Limit Using UPFC
ย 
Speed Control System for BLDC Motor by using Direct Back EMF Detection Mathod
Speed Control System for BLDC Motor by using Direct Back EMF Detection MathodSpeed Control System for BLDC Motor by using Direct Back EMF Detection Mathod
Speed Control System for BLDC Motor by using Direct Back EMF Detection Mathod
ย 
Multi-machine system with Series FACTS device: Static synchronous series comp...
Multi-machine system with Series FACTS device: Static synchronous series comp...Multi-machine system with Series FACTS device: Static synchronous series comp...
Multi-machine system with Series FACTS device: Static synchronous series comp...
ย 
Total Harmonic Distortion Analysis of a Four Switch 3-Phase Inverter Fed Spee...
Total Harmonic Distortion Analysis of a Four Switch 3-Phase Inverter Fed Spee...Total Harmonic Distortion Analysis of a Four Switch 3-Phase Inverter Fed Spee...
Total Harmonic Distortion Analysis of a Four Switch 3-Phase Inverter Fed Spee...
ย 
Modeling and Nonlinear Control of a Wind Turbine System Based on a Permanent ...
Modeling and Nonlinear Control of a Wind Turbine System Based on a Permanent ...Modeling and Nonlinear Control of a Wind Turbine System Based on a Permanent ...
Modeling and Nonlinear Control of a Wind Turbine System Based on a Permanent ...
ย 
Modeling and performance analysis of a small scale direct driven pmsg based w...
Modeling and performance analysis of a small scale direct driven pmsg based w...Modeling and performance analysis of a small scale direct driven pmsg based w...
Modeling and performance analysis of a small scale direct driven pmsg based w...
ย 
Direct Torque Control of Induction Motor Drive Fed from a Photovoltaic Multil...
Direct Torque Control of Induction Motor Drive Fed from a Photovoltaic Multil...Direct Torque Control of Induction Motor Drive Fed from a Photovoltaic Multil...
Direct Torque Control of Induction Motor Drive Fed from a Photovoltaic Multil...
ย 
Anees ppt on hcc
Anees ppt on hccAnees ppt on hcc
Anees ppt on hcc
ย 
Master slave vector controlled double induction
Master slave vector controlled double inductionMaster slave vector controlled double induction
Master slave vector controlled double induction
ย 
Master slave vector controlled double induction motor using unity power facto...
Master slave vector controlled double induction motor using unity power facto...Master slave vector controlled double induction motor using unity power facto...
Master slave vector controlled double induction motor using unity power facto...
ย 
Analysis of wind turbine driven permanent magnet synchronous generator under ...
Analysis of wind turbine driven permanent magnet synchronous generator under ...Analysis of wind turbine driven permanent magnet synchronous generator under ...
Analysis of wind turbine driven permanent magnet synchronous generator under ...
ย 
40220140505010
4022014050501040220140505010
40220140505010
ย 
Direct Torque Control of Four Switch Three Phase Inverter Fed Induction Motor...
Direct Torque Control of Four Switch Three Phase Inverter Fed Induction Motor...Direct Torque Control of Four Switch Three Phase Inverter Fed Induction Motor...
Direct Torque Control of Four Switch Three Phase Inverter Fed Induction Motor...
ย 
Carrier based hybrid pwm algorithm with reduced common mode voltage
Carrier based hybrid pwm algorithm with reduced common mode voltageCarrier based hybrid pwm algorithm with reduced common mode voltage
Carrier based hybrid pwm algorithm with reduced common mode voltage
ย 
PARAMETER IDENTIFICATION AND MODELLING OF SEPARATELY EXCITED DC MOTOR
PARAMETER IDENTIFICATION AND MODELLING OF SEPARATELY EXCITED DC MOTOR PARAMETER IDENTIFICATION AND MODELLING OF SEPARATELY EXCITED DC MOTOR
PARAMETER IDENTIFICATION AND MODELLING OF SEPARATELY EXCITED DC MOTOR
ย 

Similar to Direct Torque Control of Two Induction Motors Using the Nine-Switch Inverter

Performance Analysis Of Induction Motor For Voltage Mode And Current Mode Con...
Performance Analysis Of Induction Motor For Voltage Mode And Current Mode Con...Performance Analysis Of Induction Motor For Voltage Mode And Current Mode Con...
Performance Analysis Of Induction Motor For Voltage Mode And Current Mode Con...IRJET Journal
ย 
FLC-Based DTC Scheme for a New Approach of Two-Leg VSI Fed Induction Motor
FLC-Based DTC Scheme for a New Approach of Two-Leg VSI Fed Induction MotorFLC-Based DTC Scheme for a New Approach of Two-Leg VSI Fed Induction Motor
FLC-Based DTC Scheme for a New Approach of Two-Leg VSI Fed Induction MotorIJERA Editor
ย 
Enhanced Torque Control and Reduced Switching Frequency in Direct Torque Cont...
Enhanced Torque Control and Reduced Switching Frequency in Direct Torque Cont...Enhanced Torque Control and Reduced Switching Frequency in Direct Torque Cont...
Enhanced Torque Control and Reduced Switching Frequency in Direct Torque Cont...IJPEDS-IAES
ย 
A single rating inductor multilevel current source inverter with pwm strategie
A single rating inductor multilevel current source inverter with pwm strategieA single rating inductor multilevel current source inverter with pwm strategie
A single rating inductor multilevel current source inverter with pwm strategieIAEME Publication
ย 
A Novel Direct Torque Control for Induction Machine Drive System with Low Tor...
A Novel Direct Torque Control for Induction Machine Drive System with Low Tor...A Novel Direct Torque Control for Induction Machine Drive System with Low Tor...
A Novel Direct Torque Control for Induction Machine Drive System with Low Tor...IAES-IJPEDS
ย 
Modulation Index Variation Effect on Harmonic Behavior of Fifteen Multilevel ...
Modulation Index Variation Effect on Harmonic Behavior of Fifteen Multilevel ...Modulation Index Variation Effect on Harmonic Behavior of Fifteen Multilevel ...
Modulation Index Variation Effect on Harmonic Behavior of Fifteen Multilevel ...IJECEIAES
ย 
Small Signal Modeling Of Controller For Statcom Used In Distribution System F...
Small Signal Modeling Of Controller For Statcom Used In Distribution System F...Small Signal Modeling Of Controller For Statcom Used In Distribution System F...
Small Signal Modeling Of Controller For Statcom Used In Distribution System F...IJERA Editor
ย 
A NEW FUZZY LOGIC BASED SPACE VECTOR MODULATION APPROACH ON DIRECT TORQUE CON...
A NEW FUZZY LOGIC BASED SPACE VECTOR MODULATION APPROACH ON DIRECT TORQUE CON...A NEW FUZZY LOGIC BASED SPACE VECTOR MODULATION APPROACH ON DIRECT TORQUE CON...
A NEW FUZZY LOGIC BASED SPACE VECTOR MODULATION APPROACH ON DIRECT TORQUE CON...csandit
ย 
Simulation of 3-phase matrix converter using space vector modulation
Simulation of 3-phase matrix converter using space vector modulationSimulation of 3-phase matrix converter using space vector modulation
Simulation of 3-phase matrix converter using space vector modulationIJECEIAES
ย 
Parameter estimation of three-phase linear induction motor by a DSP-based el...
Parameter estimation of three-phase linear induction motor  by a DSP-based el...Parameter estimation of three-phase linear induction motor  by a DSP-based el...
Parameter estimation of three-phase linear induction motor by a DSP-based el...IJECEIAES
ย 

Similar to Direct Torque Control of Two Induction Motors Using the Nine-Switch Inverter (20)

Modified Look-Up Table for Enhancement of Torque Response in Direct Torque Co...
Modified Look-Up Table for Enhancement of Torque Response in Direct Torque Co...Modified Look-Up Table for Enhancement of Torque Response in Direct Torque Co...
Modified Look-Up Table for Enhancement of Torque Response in Direct Torque Co...
ย 
Performance Analysis Of Induction Motor For Voltage Mode And Current Mode Con...
Performance Analysis Of Induction Motor For Voltage Mode And Current Mode Con...Performance Analysis Of Induction Motor For Voltage Mode And Current Mode Con...
Performance Analysis Of Induction Motor For Voltage Mode And Current Mode Con...
ย 
FLC-Based DTC Scheme for a New Approach of Two-Leg VSI Fed Induction Motor
FLC-Based DTC Scheme for a New Approach of Two-Leg VSI Fed Induction MotorFLC-Based DTC Scheme for a New Approach of Two-Leg VSI Fed Induction Motor
FLC-Based DTC Scheme for a New Approach of Two-Leg VSI Fed Induction Motor
ย 
Enhanced Torque Control and Reduced Switching Frequency in Direct Torque Cont...
Enhanced Torque Control and Reduced Switching Frequency in Direct Torque Cont...Enhanced Torque Control and Reduced Switching Frequency in Direct Torque Cont...
Enhanced Torque Control and Reduced Switching Frequency in Direct Torque Cont...
ย 
Constant Switching Frequency and Torque Ripple Minimization of DTC of Inducti...
Constant Switching Frequency and Torque Ripple Minimization of DTC of Inducti...Constant Switching Frequency and Torque Ripple Minimization of DTC of Inducti...
Constant Switching Frequency and Torque Ripple Minimization of DTC of Inducti...
ย 
Reduction of total harmonic distortion of three-phase inverter using alternat...
Reduction of total harmonic distortion of three-phase inverter using alternat...Reduction of total harmonic distortion of three-phase inverter using alternat...
Reduction of total harmonic distortion of three-phase inverter using alternat...
ย 
A single rating inductor multilevel current source inverter with pwm strategie
A single rating inductor multilevel current source inverter with pwm strategieA single rating inductor multilevel current source inverter with pwm strategie
A single rating inductor multilevel current source inverter with pwm strategie
ย 
A Novel Direct Torque Control for Induction Machine Drive System with Low Tor...
A Novel Direct Torque Control for Induction Machine Drive System with Low Tor...A Novel Direct Torque Control for Induction Machine Drive System with Low Tor...
A Novel Direct Torque Control for Induction Machine Drive System with Low Tor...
ย 
Sensorless DTC of IPMSM for embedded systems
Sensorless DTC of IPMSM for embedded systemsSensorless DTC of IPMSM for embedded systems
Sensorless DTC of IPMSM for embedded systems
ย 
Contribution to the Improvement of the Performances of Doubly Fed Induction M...
Contribution to the Improvement of the Performances of Doubly Fed Induction M...Contribution to the Improvement of the Performances of Doubly Fed Induction M...
Contribution to the Improvement of the Performances of Doubly Fed Induction M...
ย 
Modulation Index Variation Effect on Harmonic Behavior of Fifteen Multilevel ...
Modulation Index Variation Effect on Harmonic Behavior of Fifteen Multilevel ...Modulation Index Variation Effect on Harmonic Behavior of Fifteen Multilevel ...
Modulation Index Variation Effect on Harmonic Behavior of Fifteen Multilevel ...
ย 
Small Signal Modeling Of Controller For Statcom Used In Distribution System F...
Small Signal Modeling Of Controller For Statcom Used In Distribution System F...Small Signal Modeling Of Controller For Statcom Used In Distribution System F...
Small Signal Modeling Of Controller For Statcom Used In Distribution System F...
ย 
Generator and grid side converter control for wind energy conversion system
Generator and grid side converter control for wind energy conversion systemGenerator and grid side converter control for wind energy conversion system
Generator and grid side converter control for wind energy conversion system
ย 
Multiple Inverters Operated in Parallel for Proportional Load Sharing in Micr...
Multiple Inverters Operated in Parallel for Proportional Load Sharing in Micr...Multiple Inverters Operated in Parallel for Proportional Load Sharing in Micr...
Multiple Inverters Operated in Parallel for Proportional Load Sharing in Micr...
ย 
A NEW FUZZY LOGIC BASED SPACE VECTOR MODULATION APPROACH ON DIRECT TORQUE CON...
A NEW FUZZY LOGIC BASED SPACE VECTOR MODULATION APPROACH ON DIRECT TORQUE CON...A NEW FUZZY LOGIC BASED SPACE VECTOR MODULATION APPROACH ON DIRECT TORQUE CON...
A NEW FUZZY LOGIC BASED SPACE VECTOR MODULATION APPROACH ON DIRECT TORQUE CON...
ย 
Simulation of 3-phase matrix converter using space vector modulation
Simulation of 3-phase matrix converter using space vector modulationSimulation of 3-phase matrix converter using space vector modulation
Simulation of 3-phase matrix converter using space vector modulation
ย 
Parameter estimation of three-phase linear induction motor by a DSP-based el...
Parameter estimation of three-phase linear induction motor  by a DSP-based el...Parameter estimation of three-phase linear induction motor  by a DSP-based el...
Parameter estimation of three-phase linear induction motor by a DSP-based el...
ย 
Ijertv2 is2554
Ijertv2 is2554Ijertv2 is2554
Ijertv2 is2554
ย 
Ijertv2 is2554
Ijertv2 is2554Ijertv2 is2554
Ijertv2 is2554
ย 
Ijertv2 is2554
Ijertv2 is2554Ijertv2 is2554
Ijertv2 is2554
ย 

More from International Journal of Power Electronics and Drive Systems

More from International Journal of Power Electronics and Drive Systems (20)

Adaptive backstepping controller design based on neural network for PMSM spee...
Adaptive backstepping controller design based on neural network for PMSM spee...Adaptive backstepping controller design based on neural network for PMSM spee...
Adaptive backstepping controller design based on neural network for PMSM spee...
ย 
Classification and direction discrimination of faults in transmission lines u...
Classification and direction discrimination of faults in transmission lines u...Classification and direction discrimination of faults in transmission lines u...
Classification and direction discrimination of faults in transmission lines u...
ย 
Integration of artificial neural networks for multi-source energy management ...
Integration of artificial neural networks for multi-source energy management ...Integration of artificial neural networks for multi-source energy management ...
Integration of artificial neural networks for multi-source energy management ...
ย 
Rotating blade faults classification of a rotor-disk-blade system using artif...
Rotating blade faults classification of a rotor-disk-blade system using artif...Rotating blade faults classification of a rotor-disk-blade system using artif...
Rotating blade faults classification of a rotor-disk-blade system using artif...
ย 
Artificial bee colony algorithm applied to optimal power flow solution incorp...
Artificial bee colony algorithm applied to optimal power flow solution incorp...Artificial bee colony algorithm applied to optimal power flow solution incorp...
Artificial bee colony algorithm applied to optimal power flow solution incorp...
ย 
Soft computing and IoT based solar tracker
Soft computing and IoT based solar trackerSoft computing and IoT based solar tracker
Soft computing and IoT based solar tracker
ย 
Comparison of roughness index for Kitka and Koznica wind farms
Comparison of roughness index for Kitka and Koznica wind farmsComparison of roughness index for Kitka and Koznica wind farms
Comparison of roughness index for Kitka and Koznica wind farms
ย 
Primary frequency control of large-scale PV-connected multi-machine power sys...
Primary frequency control of large-scale PV-connected multi-machine power sys...Primary frequency control of large-scale PV-connected multi-machine power sys...
Primary frequency control of large-scale PV-connected multi-machine power sys...
ย 
Performance of solar modules integrated with reflector
Performance of solar modules integrated with reflectorPerformance of solar modules integrated with reflector
Performance of solar modules integrated with reflector
ย 
Wind speed modeling based on measurement data to predict future wind speed wi...
Wind speed modeling based on measurement data to predict future wind speed wi...Wind speed modeling based on measurement data to predict future wind speed wi...
Wind speed modeling based on measurement data to predict future wind speed wi...
ย 
Comparison of PV panels MPPT techniques applied to solar water pumping system
Comparison of PV panels MPPT techniques applied to solar water pumping systemComparison of PV panels MPPT techniques applied to solar water pumping system
Comparison of PV panels MPPT techniques applied to solar water pumping system
ย 
Prospect of renewable energy resources in Bangladesh
Prospect of renewable energy resources in BangladeshProspect of renewable energy resources in Bangladesh
Prospect of renewable energy resources in Bangladesh
ย 
A novel optimization of the particle swarm based maximum power point tracking...
A novel optimization of the particle swarm based maximum power point tracking...A novel optimization of the particle swarm based maximum power point tracking...
A novel optimization of the particle swarm based maximum power point tracking...
ย 
Voltage stability enhancement for large scale squirrel cage induction generat...
Voltage stability enhancement for large scale squirrel cage induction generat...Voltage stability enhancement for large scale squirrel cage induction generat...
Voltage stability enhancement for large scale squirrel cage induction generat...
ย 
Electrical and environmental parameters of the performance of polymer solar c...
Electrical and environmental parameters of the performance of polymer solar c...Electrical and environmental parameters of the performance of polymer solar c...
Electrical and environmental parameters of the performance of polymer solar c...
ย 
Short and open circuit faults study in the PV system inverter
Short and open circuit faults study in the PV system inverterShort and open circuit faults study in the PV system inverter
Short and open circuit faults study in the PV system inverter
ย 
A modified bridge-type nonsuperconducting fault current limiter for distribut...
A modified bridge-type nonsuperconducting fault current limiter for distribut...A modified bridge-type nonsuperconducting fault current limiter for distribut...
A modified bridge-type nonsuperconducting fault current limiter for distribut...
ย 
The new approach minimizes harmonics in a single-phase three-level NPC 400 Hz...
The new approach minimizes harmonics in a single-phase three-level NPC 400 Hz...The new approach minimizes harmonics in a single-phase three-level NPC 400 Hz...
The new approach minimizes harmonics in a single-phase three-level NPC 400 Hz...
ย 
Comparison of electronic load using linear regulator and boost converter
Comparison of electronic load using linear regulator and boost converterComparison of electronic load using linear regulator and boost converter
Comparison of electronic load using linear regulator and boost converter
ย 
Simplified cascade multiphase DC-DC buck power converter for low voltage larg...
Simplified cascade multiphase DC-DC buck power converter for low voltage larg...Simplified cascade multiphase DC-DC buck power converter for low voltage larg...
Simplified cascade multiphase DC-DC buck power converter for low voltage larg...
ย 

Recently uploaded

Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxJoรฃo Esperancinha
ย 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxwendy cai
ย 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...Soham Mondal
ย 
microprocessor 8085 and its interfacing
microprocessor 8085  and its interfacingmicroprocessor 8085  and its interfacing
microprocessor 8085 and its interfacingjaychoudhary37
ย 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSKurinjimalarL3
ย 
power system scada applications and uses
power system scada applications and usespower system scada applications and uses
power system scada applications and usesDevarapalliHaritha
ย 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130Suhani Kapoor
ย 
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptxExploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptxnull - The Open Security Community
ย 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
ย 
Model Call Girl in Narela Delhi reach out to us at ๐Ÿ”8264348440๐Ÿ”
Model Call Girl in Narela Delhi reach out to us at ๐Ÿ”8264348440๐Ÿ”Model Call Girl in Narela Delhi reach out to us at ๐Ÿ”8264348440๐Ÿ”
Model Call Girl in Narela Delhi reach out to us at ๐Ÿ”8264348440๐Ÿ”soniya singh
ย 
Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AIabhishek36461
ย 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
ย 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxDeepakSakkari2
ย 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile servicerehmti665
ย 
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSCAESB
ย 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escortsranjana rawat
ย 
Gurgaon โœก๏ธ9711147426โœจCall In girls Gurgaon Sector 51 escort service
Gurgaon โœก๏ธ9711147426โœจCall In girls Gurgaon Sector 51 escort serviceGurgaon โœก๏ธ9711147426โœจCall In girls Gurgaon Sector 51 escort service
Gurgaon โœก๏ธ9711147426โœจCall In girls Gurgaon Sector 51 escort servicejennyeacort
ย 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Dr.Costas Sachpazis
ย 

Recently uploaded (20)

Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
ย 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptx
ย 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
ย 
microprocessor 8085 and its interfacing
microprocessor 8085  and its interfacingmicroprocessor 8085  and its interfacing
microprocessor 8085 and its interfacing
ย 
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
ย 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
ย 
power system scada applications and uses
power system scada applications and usespower system scada applications and uses
power system scada applications and uses
ย 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
ย 
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptxExploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
ย 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
ย 
Model Call Girl in Narela Delhi reach out to us at ๐Ÿ”8264348440๐Ÿ”
Model Call Girl in Narela Delhi reach out to us at ๐Ÿ”8264348440๐Ÿ”Model Call Girl in Narela Delhi reach out to us at ๐Ÿ”8264348440๐Ÿ”
Model Call Girl in Narela Delhi reach out to us at ๐Ÿ”8264348440๐Ÿ”
ย 
Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AI
ย 
young call girls in Rajiv Chowk๐Ÿ” 9953056974 ๐Ÿ” Delhi escort Service
young call girls in Rajiv Chowk๐Ÿ” 9953056974 ๐Ÿ” Delhi escort Serviceyoung call girls in Rajiv Chowk๐Ÿ” 9953056974 ๐Ÿ” Delhi escort Service
young call girls in Rajiv Chowk๐Ÿ” 9953056974 ๐Ÿ” Delhi escort Service
ย 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
ย 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptx
ย 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile service
ย 
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentation
ย 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
ย 
Gurgaon โœก๏ธ9711147426โœจCall In girls Gurgaon Sector 51 escort service
Gurgaon โœก๏ธ9711147426โœจCall In girls Gurgaon Sector 51 escort serviceGurgaon โœก๏ธ9711147426โœจCall In girls Gurgaon Sector 51 escort service
Gurgaon โœก๏ธ9711147426โœจCall In girls Gurgaon Sector 51 escort service
ย 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
ย 

Direct Torque Control of Two Induction Motors Using the Nine-Switch Inverter

  • 1. International Journal of Power Electronics and Drive System (IJPEDS) Vol. 9, No. 4, December 2018, pp. 1552~1564 ISSN: 2088-8694, DOI: 10.11591/ijpeds.v9.i4.pp1552-1564 ๏ฒ 1552 Journal homepage: http://iaescore.com/journals/index.php/IJPEDS Direct Torque Control of Two Induction Motors Using the Nine-Switch Inverter Draoui Abdelghani1 , Allaoua Boumediรจne2 1 Laboratoire de Commande, Analyse et Optimisation des Systรจmes Electro-Energรฉtiques (CAOSEE), UTMB, Algeria 2 Department of Electrical Engineering, University of Tahri Mohammed, Algeria Article Info ABSTRACT Article history: Received Jul 24, 2018 Revised Sep 11, 2018 Accepted Sep 15, 2018 The Nine-Switch Inverter (NSI) is a recently developed dual output converter. It can be used to drive two three-phase loads independently. As a substitute to two separate conventional voltage source inverters, the NSI has been, already, proposed in various industrial applications to reduce the number of semiconductor switches and its associated energy losses and drive circuitry. On the other hand, the Direct Torque Control (DTC) is a robust control scheme of AC motors, which consist of selecting proper state vectors of a conventional voltage source inverter. The NSI, having a different working principle from the conventional voltage source inverter and taking into account the varying influence of active space vectors on motorโ€™s torque and stator flux, a Direct Torque Control is suggested in this paper to, efficiently, drive two induction motors independently, while minimizing the torque and stator flux ripples of both motors. Simulations results confirm the effectiveness of the proposed algorithm. In addition, application of this newly proposed control scheme in operation of an Electric Vehicule (EV) is demonstrated. Keyword: DTC Induction motor SVM EV Copyright ยฉ 2018 Institute of Advanced Engineering and Science. All rights reserved. Corresponding Author: Draoui Abdelghani, Department of Electrical Engineering, CAOSEE Laboratory, University of Tahri Mohamed, Bechar, Algeria, University of Tahri Mohamed, Bechar, B.P 417 Bechar 08000, Algeria. Email: draoui.abdelghani@gmail.com 1. INTRODUCTION One of the developmental trends, followed by researchers in the field of power electronics, nowadays, is to come up with new converter topologies with a reduced number of semiconductor switches [1]-[3]. These switches represent the most expensive parts of the converter and are responsible, to a large extent, for the energy losses due to the switching operation. For example, as a substitute of the dual inverter, which consists of two separate two-level inverters connected in parallel, several new topologies has been developed, namely, the B4 inverter [4], the Five Leg Inverter [5] and the Nine Switch Inverter(NSI) [6]. Having the least number of semiconductor switches as compared to the aforementioned inverter topologies, the NSI has been suggested in various industrial applications [7]-[11]. Due to its special working mechanism, this inverter has raised a new challenge, which is the adaptation of the classical control methods developed based on the conventional inverter topologies [12]-[14]. In essence, In order to ensure the independent control of the two NSI loads, this inverter can only supply one of its two loads, at any given instant. The NSI has been, also, suggested in a DTC control scheme for driving two induction motors [15]. This suggested DTC control scheme consist of controlling the two loads in alternate manner with equal time of supply of both loads. Although this proposed control scheme resulted in a relatively good performance, the varying properties of the inverterโ€™s state vectors with the operating condions, will lead to high torque and stator flux ripples, as stated in [16],[17]. As a remedy to this problem, the torque and stator flux errors of
  • 2. Int J Pow Elec & Dri Syst ISSN: 2088-8694 ๏ฒ Direct Torque Control of Two Induction Motors Using the Nine-Switch Inverter (Draoui Abdelghani) 1553 each motor are calculated and the influence of the NSI space vectors on each motorโ€™s torque and stator flux is estimated to select the motor to be supplied, next. The advantage of the newly proposed DTC scheme over the older DTC control scheme will be relevant, when the two motors are operating in different speeds and loading conditions. In this paper, a new algorithm for a DTC control scheme is suggested, based on selection of the most appropriate inverter state vector. This paper is organized as follows. Section 2 describes the working principle of the Nine-Switch Inverter. Section 3 explains, briefly, the DTC of the induction motor. Section 4 details the analytical studies revealing the properties of active vectors in the different operating conditions. The proposed algorithm for driving two induction motors fed by the NSI will be detailed in Section 5. Section 6 presents results and discussion. 2. THE NINE SWITCH INVERTER The NSI has three lesser switches as compared to the classical dual output inverter, it has been developed by replacing the middle six switches of the classical dual output Inverter by only three switches, both inverters are shown in Figure 1. Figure 1. (a) The classical Dual output inverter (b) The NSI The NSI can be viewed as two two-level inverters operating in alternate manner, the upper six switches constitute a classical six switch VSI, in the other hand, the six lower switches, also, constitute another six switch VSI, hence, the middle three switches are shared between the two sub-inverters. Originally, authors applied the Sinusoidal PWM control scheme, for each leg, the gate signal of the upper switch is generated by comparing the upper half of a triangular carrier signal with a sinusoidal reference signal. The gate signal of the lower switch is generated by comparing the lower half of the same triangular carrier signal with another sinusoidal reference signal. In order to avoid closing the three switches of the same leg simultaneously and therefore shorting the DC source, the gate signal of the middle switch is generated by the output of a XOR logic gate whose inputs are the two gate signals for the upper and lower switches, Figure 2 shows generated gate signals from a carrier signal and two reference signals.
  • 3. ๏ฒ ISSN: 2088-8694 Int J Pow Elec & Dri Syst, Vol. 9, No. 4, December 2018 : 1552 โ€“ 1564 1554 Figure 2. carrier signal, references signals and gate signals of the NSI using SPWM: (a) carrier signal and references signals of upper and lower switches. (b) gate signal of the upper switch reference (c)gate signal of the lower gate signal, (d) gate signal of the middle signal Each of the three legs of the NSI , is composed of a three switches and only one switch is allowed to be open, at time, in each leg, to avoid : 1- supplying two loads at the same time which will lead to loss of independency of control. 2- keeping terminals of any of the two motors open-circuited, therefore, a combination of 27 switching states are allowed in the control of the Nine Switch Inverter [18]. If two Y-connected loads are to be driven by the NSI, the peak fundamental phase voltage of each load is given as follows: Vanpeak(i) = mi.Vin 2 (1) To operate in the linear modulation region of the SPWM, the two reference signals are constrained to stay within the horizontal band of the carrier signal without overlapping, therefore the following inequality has to be, always, satisfied: ๐‘š1 + ๐‘š2 โ‰ค 1 (2) The reference signals of the ith load has the following form: ๐‘‰๐‘Ÿ๐‘’๐‘“๐‘– = ๐ด๐‘–. sin(2๐œ‹. ๐‘“๐‘–) + ๐‘œ๐‘“๐‘“๐‘ ๐‘’๐‘ก๐‘– (3) By manipulating amplitudes and offsets of both sinusoidal reference signals within the carrier signal band, the percentage of use of the DC source is divided accordingly between the two loads. When applying Space Vector Modulation [18], as it is the case of DTC control, a gain of 15% in the sum of modulation indices, which translate to higher torque production, hence, the inequality condition in equation 2 becomes : ๐‘š1 + ๐‘š2 โ‰ค 2 โˆš3 (4) 3. DIRECT TORQUE CONTROL 3.1. Direct Torque Control Technique The Direct Torque Control (DTC) has been introduced in the second half of the 1980s [19],[20], although a relatively new control strategy, DTC has quickly gained industrial acceptance [21]. In the conventional DTC scheme, the stator flux and the electromagnetic torque are controlled by proper selection of inverter states vectors. For proper operation of DTC control scheme, an accurate model for the induction motor is required, since stator flux and the electromagnetic torque are estimated, based the motor model. The two-phase dynamic model of IM in the stationary dq frame: ๐‘‰๐‘ ๐‘‘๐‘ž = ๐‘…๐‘ ๐‘–๐‘ ๐‘‘๐‘ž + ๐‘‘ ๐‘‘๐‘ก (๐œ“๐‘ ๐‘‘๐‘ž) ๐‘‰๐‘Ÿ๐‘‘๐‘ž = 0 = ๐‘…โ€ฒ๐‘Ÿ๐‘–๐‘Ÿ๐‘‘๐‘ž + ๐‘‘ ๐‘‘๐‘ก (๐œ“๐‘Ÿ๐‘‘๐‘ž) โˆ’ ๐‘—๐‘ค๐‘Ÿ๐œ“๐‘Ÿ๐‘‘๐‘ž ๐œ“๐‘ ๐‘‘๐‘ž = ๐ฟ๐‘ ๐‘–๐‘ ๐‘‘๐‘ž + ๐ฟ๐‘š๐‘–๐‘Ÿ๐‘‘๐‘ž ๐œ“๐‘Ÿ๐‘‘๐‘ž = ๐ฟ๐‘š๐‘–๐‘ ๐‘‘๐‘ž + ๐ฟโ€ฒ๐‘Ÿ๐‘–๐‘Ÿ๐‘‘๐‘ž (5) Derivative of stator flux is equal to the stator EMF, hence, stator flux magnitude strongly depends on stator voltage. ๐‘‘ ๐‘‘๐‘ก (๐œ“๐‘ ๐‘‘๐‘ž) = ๐‘’๐‘‘๐‘ž = ๐‘‰๐‘ ๐‘‘๐‘ž โˆ’ ๐‘…๐‘ ๐‘–๐‘ ๐‘‘๐‘ž (6) If voltage drop across Rs is ignored, stator flux can be controlled by stator voltage applied: โˆ†๐œ“๐‘ ๐‘‘๐‘ž = (๐‘‰๐‘ ๐‘‘๐‘ž)โˆ†๐‘ก (7)
  • 4. Int J Pow Elec & Dri Syst ISSN: 2088-8694 ๏ฒ Direct Torque Control of Two Induction Motors Using the Nine-Switch Inverter (Draoui Abdelghani) 1555 The developed torque is proportional to the sine of angle between stator and rotor flux vectors ฮธsr ๐‘‡๐‘’ โƒ—โƒ—โƒ— = 3 2 ๐‘ƒ 2 ๐ฟ๐‘š ๐œŽ๐ฟ๐‘ ๐ฟโ€ฒ๐‘Ÿ ๐œ“๐‘Ÿ โƒ—โƒ—โƒ—โƒ— โŠ— ๐œ“๐‘† โƒ—โƒ—โƒ—โƒ— (8) |๐‘‡๐‘’| = 3 2 ๐‘ƒ 2 ๐ฟ๐‘š ๐œŽ๐ฟ๐‘ ๐ฟโ€ฒ๐‘Ÿ |๐๐’“||๐๐‘บ| sin ๐œƒ๐‘ ๐‘Ÿ (9) Angle of ฯˆS โƒ—โƒ—โƒ—โƒ—โƒ—โƒ— is also dependent on stator voltage, hence, |Te| can also be controlled by applying the proper vector to change ฮธsr. 3.2. DTC speed mode control scheme The DTC control scheme has two modes of operation, the DTC torque mode where motor torque is controlled directly and the DTC speed mode where motor torque is controlled via motor speed. The DTC speed mode control scheme is shown in Figure 3. Figure 3. The DTC speed mode control scheme In the DTC speed mode control scheme, three phase stator currents, stator voltages are measured, motor speed is estimated or measured using an encoder. Stator flux magnitude and angle are estimated from the obtained currents and voltages. Measured or estimated speed and measured stator flux amplitude are compared with their respective reference values. The stator flux error is fed directly to a hysteresis controller, where the motor speed error is fed to a PI controller then the output of this latter is fed to another hysteresis controller. The output of hysteresis controllers along with the stator flux angle will yield the proper vector to supply according to a predefined switching table. 3.3. Adaptation of DTC control scheme for use with the NSI For an independent control of the two loads, the NSI can only supply one of its two loads at a time, when one load is supplied, the phases of the second load are short-circuited through one of the DC rails. In a DTC point of view, when an active state vector is applied to the inverter composed of the upper six switches, a zero vector is applied to the inverter composed of the six lower switches. While the effect of an active vector on stator flux and torque depends on stator flux space vector position, the zero vector has little effect on flux but it will reduce the torque [22]. This property justify the priority of controlling the torque over the control of stator flux in the proposed algorithm. In [15], authors suggested a DTC control scheme for two induction motors fed by the NSI as shown in Figure 4, where the two motors are fed in alternate manner with equal time of supply, however, analytical studies performed by [23], show that the rate of increase and the rate of decrease in both torque and stator flux values are not equal for every two successive switchings and therefore controlling the two motors in
  • 5. ๏ฒ ISSN: 2088-8694 Int J Pow Elec & Dri Syst, Vol. 9, No. 4, December 2018 : 1552 โ€“ 1564 1556 alternate manner with 50% duty cycle, does not, necessarily, guarantee optimal results, as it will cause asymmetry and high ripples. Figure 4. The proposed DTC control scheme in [15] using the NSI The control scheme proposed by authors is very similar to the conventional control scheme shown in Figure 3, the only difference is that when a variable SA, SB and SC are assigned by the switching Table 1 the synchronization block set all variable SX, SY and SZ to zero for 50% of the sampling time, for the other half of the sampling time SA, SB and SC are set to one while SX, SY and SZ are assigned by the switching Table 2. 4. TORQUE AND STATOR FLUX RATES OF CHANGE 4.1. Rate of change in motor torque In the conventional switching selection method [23], the increase and decrease in torque rates vary with the speed of motor, โˆ†๐‘‡๐‘’ โ†‘= [๐‘ƒ(๐œ“๐‘Ÿ โƒ—โƒ—โƒ—โƒ— โŠ— ๐‘ฃ๐‘† โƒ—โƒ—โƒ— ) โˆ’ ๐‘ƒ๐‘ค๐‘Ÿ๐œ“๐‘  โƒ—โƒ—โƒ—โƒ— ยฐ ๐œ“๐‘Ÿ โƒ—โƒ—โƒ—โƒ— โˆ’ ๐‘…๐‘š๐‘‡๐‘’]๐‘‡๐‘“/๐ฟฯƒ (10) โˆ†๐‘‡๐‘’ โ†“= [โˆ’๐‘ƒ๐‘ค๐‘Ÿ๐œ“๐‘  โƒ—โƒ—โƒ—โƒ— ยฐ ๐œ“๐‘Ÿ โƒ—โƒ—โƒ—โƒ— โˆ’ ๐‘…๐‘š๐‘‡๐‘’]๐‘‡๐‘“/๐ฟฯƒ (11) Where Tf is the sampling period, โŠ— stands for vector product while ยฐ denotes the scalar product and ๐‘…๐‘š = (๐ฟ๐‘Ÿ๐‘…๐‘  + ๐ฟ๐‘ ๐‘…๐‘Ÿ)/ ๐ฟ๐‘š ; ๐ฟฯƒ = (๐ฟ๐‘ ๐ฟ๐‘Ÿ โˆ’ ๐ฟ๐‘š 2 )/๐ฟ๐‘š The analysis can be summarized in the Table 1. Table 1. Increase and decrease rates in Torque Vs Motor Speed [23] Low speed region Medium speed region High Speed Region Increase Vs Decrease in Torque |โˆ†Teโ†‘| >|โˆ†Teโ†“| |โˆ†Teโ†‘| โ‰ˆ |โˆ†Teโ†“| |โˆ†Teโ†‘| <|โˆ†Teโ†“| The asymmetry of torque ripple in the various speed regions, are shown in figures from the experiments conducted by the same authors [23]. From the Table 1 and Figure 5, we can clearly notice that driving the two loads with different speeds, will result in higher and asymmetrical torque errors, therefore, supplying the two motors in alternate manner with an equal time of application will worsen the situation. The proposed algorithm will supply the motor with the higher torque error.
  • 6. Int J Pow Elec & Dri Syst ISSN: 2088-8694 ๏ฒ Direct Torque Control of Two Induction Motors Using the Nine-Switch Inverter (Draoui Abdelghani) 1557 (a) (b) (c) Figure 5 . Torque ripples in (a) Low Speed Region (b) Medium Speed Region (c) High Speed Region [23] 4.2. Rate of change in stator flux: Given that the angle ฮธ (ฮธ ฯต [-30ยฐ to 30ยฐ]) which is defined as the angle between stator flux space vector ฯ† and the active vector Vk, the effect of the applied active vectors Vk+1 and Vk+2 on stator flux are demonstrated in the Table 2 [23]. From the Table 2 and as illustrated in Figure 6, it is evident that selection of vectors near the borders of the sectors will lead to a unbalanced change in stator flux error, which require immediate selection of several active vectors to compensate for the change, therefore, supplying two motors in an alternate fashion with an equal time of application will not help in restoring stator flux to its tolerable values. Table 2. Influence of vector Vs Stator flux space vector location ฮธ โ‰ˆ - 30ยฐ ฮธ โ‰ˆ 30ยฐ Vk+1 applied small increase large decrease Vk+2 applied large increase small decrease
  • 7. ๏ฒ ISSN: 2088-8694 Int J Pow Elec & Dri Syst, Vol. 9, No. 4, December 2018 : 1552 โ€“ 1564 1558 Figure 6. Influence of vector Vs Stator flux space vector location In the DTC control scheme, in the low speed region, the stator flux ripples are unacceptably high [23]. Findings summarized in Table 2 can be exploited to reduce ripples by selecting the load whose vector have the moderate effect on the stator flux. In other words, the load whose vector is closer to the center of the sector being selected. 5. THE PROPOSED ALGORITHM In order to reduce ripples of the electromagnetic torque and the stator flux in both motors and to ensure a relatively higher switching frequency, the aforementioned facts, are exploited to develop a new control scheme based on the following algorithm (Figure 7): Figure 7. The Flow chart of the developed algorithm For the reasons stated earlier, control of torque has been given higher priority over the control of stator flux. If any one of the motors or both are having a high torque error, the load with the higher torque error will be supplied by the inverter, in the other hand, if the torque errors of both loads, are acceptable, the
  • 8. Int J Pow Elec & Dri Syst ISSN: 2088-8694 ๏ฒ Direct Torque Control of Two Induction Motors Using the Nine-Switch Inverter (Draoui Abdelghani) 1559 load whose vector have the least influence on the stator flux change will be selected, in case of operation in the low speed region. Otherwise, the selection is performed in an alternate manner. Figure 8. Simulinkยฎ Block diagram of the entire System Figure 9. Synchronization Block and Matlabยฎ Function File
  • 9. ๏ฒ ISSN: 2088-8694 Int J Pow Elec & Dri Syst, Vol. 9, No. 4, December 2018 : 1552 โ€“ 1564 1560 6. RESULTS AND DISSCUSION In order to demonstrate the indpendent control of both motors and to investigate the validity of the proposed algorithm, Simulation using the Matlab/Simulinkยฎ software is carried out. Two induction motors are driven with different combinations of speed profiles (120, 300 rad/s), while applying a nominal torque load (26 N.m) in each speed combination, the stator flux of both motor is set to 0.9 Wb. In the low speed region, the stator flux of each motor has high ripples, this is one of the drawbacks of the original DTC control scheme. the significant voltage drop in stator resistance leads to a poor estimation of stator flux values, hence, a wrong state vector is applied. Several works [24]-[26] has been proposed to have a better estimate of stator flux value. In our proposed control scheme, the algorithm will supply the motor whose active vector has the moderate influence to mitigate the sharp increase of stator flux. Stator flux of the two motors in shown in Figure 10. (a) (b) Figure 10. Stator Flux magnitude of: (a) Motor 1. (b) Motor 2 At first, the speed of the two motors is set to 120 rad/sec in a time interval of 200 milliseconds, due to this high acceleration rate, 120% of the nominal torque command is requested by the control system, to reach the assigned speed in time. At time 0.4 seconds, a nominal load is coupled to both motors, the motors torques are increased to keep both motors running at the assigned speed, a slight decrease is noticed (i.e a steady state error < 1% of the nominal speed). In the medium speed region, the algorithm will control the NSI to supply the load with the larger torque error, Figure 11 and Figure 12 show acceptable torque ripples.
  • 10. Int J Pow Elec & Dri Syst ISSN: 2088-8694 ๏ฒ Direct Torque Control of Two Induction Motors Using the Nine-Switch Inverter (Draoui Abdelghani) 1561 Figure 11. Motor 1 Torque Vs its reference value Figure 12. Motor 2 Torque Vs its reference value After driving both loads with a medium speed, the speed of the first load is increased up to 300 rad/sec while the second load is kept running at a medium speed, once again, 120% of the nominal is produced at the first load to accelerate. a nominal load is applied afterward, Figures 11 and 12 show that the torque ripples of the first load are slightly larger than those of the second load due to the difference in speeds. On the other hand, less than 1% of steady state error is noticed in speeds of both loads. As stated earlier, based on remarks from Table 1, the torque ripples of the first motor would be higher, if the older control scheme is used. The speed of the second load is increased to the nominal speed (300 rad/sec) at time 2.0 seconds, a 120% of nominal torque command is applied to accelerate, a nominal load is applied to both motors, ripples in both stator flux and torque of each motor remains whithin limits, which ensures a good regulation of speed of both motors as shown, in Figures 13 and 14.
  • 11. ๏ฒ ISSN: 2088-8694 Int J Pow Elec & Dri Syst, Vol. 9, No. 4, December 2018 : 1552 โ€“ 1564 1562 Figure 13. Motor 1 speed Vs its reference value Figure 14. Motor 1 speed Vs its reference value In the DTC speed mode, the speed of both motors are controlled instead of torques, this facts justify the abrupt rise in torque when acceleration of any of the two motors is requested. A saturation unit is used in the control scheme to avoid forcing the two motors to develop more than 120% of their nominal torque, In practice, an anti-windup unit is added to the PI controller to compensate for the overshoot inherent in Integral part of the controller [27],[28]. The advantage of the present DTC control scheme over the old DTC control scheme, is evident in two instances, 1- when the two motors are loaded and running at low speeds, inaccurate estimation of stator flux may occur and the alternate selection of active state vectors for the two motors will worsen the performance as it would lead to an abrupt change in stator flux which require application of several active vectors to re-establish stator flux to permissible values. 2- If the old DTC control is opted for, when one of the motors is running at low speed and the other motor is running at high speed, the rate of decrease of torque in the latter motor will be more significant, eventually, leading to abrupt decrease in its speed and a slow response of this motor to reach the assigned speed. The NSI has been already proposed in Hybrid Electric Vehicle (HEV) [29], similarly, a comprehensive literature review of the DTC control scheme and its application in EV field is detailed in [30] and as demonstrated in the present paper, the combination of DTC control with the use NSI makes it well suited for use in Electric Vehicle EV and HEV applications. The use of the NSI as a substitute to two separate two-level inverters, as shown in Figure 15, will help reduce the overall cost and energy consumption of EVs.
  • 12. Int J Pow Elec & Dri Syst ISSN: 2088-8694 ๏ฒ Direct Torque Control of Two Induction Motors Using the Nine-Switch Inverter (Draoui Abdelghani) 1563 (a) (b) Figure 14. Topology of: (a) Conventional EV (b) Suggested EV 7. CONCLUSION In this paper, a new Direct Torque control has been developed to drive two induction motors, independently, via the Nine-Switch Inverter. Simulation results show acceptable torque and stator flux ripples for each motor, in different speed profiles. Further improvements can be made, by using the a motor model which takes into account the iron core losses and optimal results can be obtained when more advanced stator flux estimators are used. Being effective in driving two motors with different speed, the NSI has been proved to be well suited for EVs applications. REFERENCES [1] Thiyagarajan V. and Somasundaram P., โ€œA New Level Symmertrical Inverter with Reduced Switch Count,โ€ International Journal of Power Electronics and Drive Systems, vol/issue: 9(2) pp. 921-925, 2018. [2] F. Chouaf and S. Saad, โ€œA New Structure of the Nine Level Inverter Used as Active Power Filter with a Reduced Number of Swiches,โ€ International Journal of Power Electronics and Drive Systems, vol/issue: 9(1), pp. 198-209, 2017. [3] T. Muhammad, et al., โ€œCascaded Symmetric Multilevel Inverter with Ruduced Number of Controlled Switches,โ€ International Journal of Power Electronics and Drive Systems, vol/issue: 8(2), pp. 795-803, 2017. [4] F. Blaabjerg, et al., โ€œA new optimized space-vector modulation strategy for a component-minimized voltage source inverter,โ€ IEEE Trans. PowerElectron., vol/issue: 12(4), pp. 704โ€“714, 1997. [5] M. Jones, et al., โ€œFive-leg inverter PWM technique for reduced switch count two-motor constant power applications,โ€ IET Electr. Power Appl., vol/issue: 2(5), pp. 275โ€“287, 2008. [6] T. Kominami and Y. Fujimoto, โ€œA novel nine-switch inverter for independent control of two three-phase loads,โ€ Conf. Rec. IEEE IAS Annu.Meeting, pp. 2346โ€“2350, 2007. [7] M. Heydari, et al., โ€œA Novel Variable-Speed Wind Energy System Using Permanent-Magnet Synchronous Generator and Nine-Switch AC/AC Converter,โ€ 1st Power Electronic & Drive System Technologies Conference (PEDSTC), Tehran, Iran, pp. 5-9, 2010. [8] C. Liu, et al., โ€œA Novel Three-phase Three-leg AC/AC Converter Using Nine IGBTs,โ€ IEEE Transaction on Power Electronic, vol/issue: 24(5), pp. 1151-1160, 2009. [9] L. R. Limongi, et al., โ€œDual hybrid power filter based on a nine-switch inverter,โ€ Elsevier Electric Power Systems Research, vol. 117, pp. 154-162, 2014. [10] M. S. Diab, et al., โ€œA nine-switch-converter-based integrated motor drive and battery charger system for EVs using symmetrical six-phase machines,โ€ IEEE Trans. Ind. Electron., vol/issue: 63(9), pp. 5326-5335, 2016. [11] C. A. Reusser, โ€œFull-electric ship propulsion based on a dual nine-switch inverter topology for dual three-phase induction motor drive,โ€ 2016 IEEE Transportation Electrification Conference and Expo (ITEC), pp. 1-6, 2016. [12] D. Abdelghani and A. Boumรฉdiene, โ€œSpace Vector Modulation of Quasi-Z Source and Nine-Switch Inverter,โ€ Electrotehnica, Electronica, Automatica (EEA), vol/issue: 66(1), pp. 80-86, 2018. [13] F. Gao, et al., โ€œOptimal pulsewidth modulation of nine-switch converter,โ€ Power Electronics, IEEE Transactions on, vol/issue: 25(9), pp. 2331โ€“2343, 2010. [14] X. Li, et al., โ€œNew PWM strategy for nine-switch inverters with minimum number of semiconductor switching,โ€ 2014 International Power Electronics and Application Conference and Exposition, pp. 406-410, 2014. [15] M. Abbache, et al., โ€œDirect torque control of nine switches inverter-dual induction motors,โ€ Conf. Rec. IEEE MED, pp. 810โ€“815, 2014. [16] J. W. Kang and S. K. Sul, โ€œAnalysis and prediction of inverter switching frequency in direct torque control of induction machine based on hysteresis bands and machine parameters,โ€ IEEE Trans. Ind. Electron., vol. 48, pp. 545โ€“553, 2001. [17] Casadei D., et al., โ€œAnalytical investigation of torque and flux ripple in DTC schemes for induction motors,โ€ 23rd International conference on industrial electronics, control and instrumentation (IECON 97), vol. 2, pp. 552โ€“6, 1997. [18] S. M. Dehghan, et al., โ€œSpace vectors modulation for nine-switch converters,โ€ IEEE Trans. Power Electron., vol. 25, pp. 1488โ€“1496, 2010. [19] I. Takahashi and T. Noguchi, โ€œA new quick-response and high-efficiency control strategy of an induction motor,โ€ IEEE Trans. Ind. Appl, IA, vol/issue: 22(5), pp. 820โ€“827, 1986.
  • 13. ๏ฒ ISSN: 2088-8694 Int J Pow Elec & Dri Syst, Vol. 9, No. 4, December 2018 : 1552 โ€“ 1564 1564 [20] M. Depenbrock, โ€œDirect self-control (DSC) of inverter-fed induction motors,โ€ IEEE Trans. Power Elect., vol/issue: 3(4), pp. 420โ€“429, 1988. [21] P. Tiitinen, et al., โ€œThe next generation motor control method: Direct torque control (DTC),โ€ Europ. Power Elect. J., vol/issue: 5(1), pp. 14โ€“18, 1995. [22] N. R. N. Idris and A. H. M. Yatim, โ€œDirect torque control of induction machines with constant switching frequency and reduced torque ripple,โ€ IEEE Trans. Ind. Electron., vol/issue: 51(4), pp. 758-767, 2004. [23] J. Chen and Y. Li, โ€œVirtual vectors based predictive control of torque and flux of induction motor and speed sensorless drives,โ€ Conf. Rec. IEEE-IAS Annu. Meeting, pp. 2606โ€“2613, 1999. [24] I. Alsofyani and N. Idris, โ€œSimple Flux Regulation for Improving State Estimation at Very Low and Zero Speed of a Speed Sensorless Direct Torque Control of an Induction Motor,โ€ IEEE Transactions on Power Electronics, vol/issue: 31(4), pp. 3027-3035, 2016. [25] Y. A. Alamri, et al., โ€œImproved Stator Flux Estimation for Direct Torque Control of Induction Motor Drives,โ€ International Journal of Power Electronics and Drive Systems, vol/issue: 7(4), pp. 1049-1060, 2016. [26] I. Alsofyani and N. R. N. Idris, โ€œLookup-Table-Based DTC of Induction Machines With Improved Flux Regulation and Extended Kalman Filter State Estimator at Low-Speed Operation,โ€ IEEE Transactions on Industrial Informatics, vol/issue: 12(4), pp. 1412-1425, 2016. [27] M. J. Li and L. Q. Meng, โ€œA New Anti-Windup PI Controller for Direct Torque Control System,โ€ TELKOMNIKA Indonesian Journal of Electrical Engineering, vol/issue: 12(7), pp. 5268- 5274, 2014. [28] F. C. Ferreira, et al., โ€œAnti wind-up techniques applied to real tank level system performed by PI controllers,โ€ 20th International Conference on SystemTheory, Control and Computing (ICSTCC), pp. 263โ€“268, 2016. [29] M. Dehghan, et al., โ€œHybrid ElectricVehicle based on Bidirectional Z-Source Nine-Switch Inverter,โ€ IEEE Transactions on Vehicular Technology, vol/issue: 59(6), pp. 2641-2653, 2010. [30] T. Sutikno, et al., โ€œA review of direct torque control of induction motors for sustainable reliability and energy efficient drives,โ€ Renew Sustain Energy Rev., vol. 32, pp. 548โ€“58, 2014. NUMENCLATURE Lโ€™r : Rotor Inductance refered to the stator Rโ€™r : Rotor Resistance refered to the stator Rs : Stator Resistance Ls : Stator Inductance LM : Mutual Inductance ๐›น โƒ—โƒ— s : Stator Flux Space Vector ๐›น โƒ—โƒ— r : Stator Flux Space Vector ฯƒ : Leakage coefficient. Parameters of simulated motors: Line to Line Voltage : 400 V Number of pole pairs : 2 poles Stator resistance : 1.37 ฮฉ Stator inductance : 0.1459 H Rotor resistance : 1.1 ฮฉ Rotor inductance : 0.149 H Mutual inductance : 0.141 H Moment of Inertia : 0.1 Kg/m2