SlideShare a Scribd company logo
1 of 4
Page - 1 - of 4
- 1 - | P a g e
CURRICULAM VITE
1. NAME : PRAVEEN DINKAR CHANNE.
2. DATE OF BIRTH : 8TH January 1974.
3. QUALIFICATION : B.E. in Electrical Engineering.
4. TOTAL EXPERIENCE : 19 Years. , Working as DGM
Reliability Management through Electrical condition monitoring
(RCM) of electrical equipments i.e. Health Diagnostic testing of
Transformers, HT Motors and switchgears etc., Transformer
oil testing Lab (NABL accredited).
Central Motor overhauling workshop, Central Electrical
maintenance support services to all plant/dept of Essar steel
i.e. SMP,HBI, HSM, CSP, CRM, Utility, BF & Sinter, ASU,
power plants etc. Support to commissioning blast furnace and
other projects.
Maintenance of Heavy duty ports Cranes & EOT. Maintenance
of AC/DC Drives, PLC’s etc., Erection, Commissioning,
maintenance & testing of LT/HT switch-gears, Sub-stations,
Generators, Material handling, crushing & Batching plants.
5. EDUCATIONAL QUALIFICATION :
a) Bachelor of Engineering in Electronics
& Power (Electrical Engineering) from
Nagpur University, in May-1995 with First class
b) Diploma in Electrical Engineering with First
Class in B.T.E. Maharashtra, in 1992.
c) Post graduate Diploma in Management from
I.G.N.O.U. in Jun- 2003.
6. PROFESSIONAL CERTIFICATION : Certified Energy Manager from bureau of energy
efficiency (2012)
7. LICENCE : Electrical supervisory license holder of
Maharashtra state.
8. COMPUTER PROFICIENCY : MS-Office, SAP operation.
9. PERMANENT ADDRESS : V- 55, Narendra Nagar, Nagpur- 440 015,
Mob. No. 09561003082
10. ADDRESS FOR : F-3/13, Nandniketan, Essar Township,
CORRESPONDENCE Surat-Hazira Road, Hazira, Surat,
Gujarat – 394 270.
Mob. No. 09879101056;9586227409
11. E-mail ID : pchanne@yahoo.com
Page - 2 - of 4
- 2 - | P a g e
CURRICULAM VITE
12. DETAIL EXPERIENCE :
1) From 04/09/2006 working with “ESSAR STEEL INDIA LTD”. , Hazira, Surat.
As Deputy General Manager- Electrical, Central Electrical & Instrumentation
Dept.(CEID), Heading all Electrical activity of Central Dept. (from 2006 to till date)
 Central Electrical maintenance (CMD) services to all plants/depts. of Essar steel i.e.
SMP,HBI, HSM, CSP, CRM, Utility, Blast Furnace & Sinter, ASU, power plants etc.
 Supports to depts. for measure/calculate the energy efficiency of various electrical
system like transformers/motors etc. & Energy saving projects.
 Electrical equipments “Reliability Condition Monitoring” and health assessment - Plan
and executing for optimum monitoring of all electrical equipments and suggest
predictive maintenance of equipments, co-ordinate, interpret and provide solutions in
context with the Electrical HT equipments activities of all units of Essar steel, Hazira.
 Responsible for Reliability of 460 transformer of Essar complex, Hazira
 “Transformer oil Testing Lab” - Developed and established for DGA & General Test, its
analysis & interpretation of DGA for more than 1000 sample annually, for quality assurance
acquired NABL accreditation of Transformer oil Testing Lab (NABL certificate no. : T2286).
 Transformer Health Diagnostic testing & Condition Monitoring - facility developed &
established for transformers, CT/CVT up to 220KV of Essar complex.
 As Transformer Club leader – Provided solutions and Co-ordination for reliability of
transformers through best maintenance practices to various Dept. and sharing MIS on
transformers through monthly club meeting.
 Responsible for Reliability of 450 HT motors of Essar complex, Hazira
 HT Motors & Generators Health Diagnostic & Condition Monitoring- facility developed &
established for Essar complex by setup various specialize testing facility.
 Established & handling “Centralized Motor Workshop” for AC/DC & HT Motors.
 Main achievement – Highest capacity 2.9MW HT motor & 600KW LT slip ring shear motor
overhauled, motor leads brazing, motor Insulation quality improvement testing after
overhauling confirming through various testing like tan delta & capacitance test etc.
 Support for Shutdown maintenance of AC/DC motor for different Dept/plants.
 As Motor Club leader – Identify route cause of motor failure and degradation motors,
provided solution for reliability of motors and sharing the problem in various motors across
complex through Motor club. Co-ordinate with store and depts. for standardization &
inventory control of motors. Ensuring implementation of best maintenance practices & cost
reduction activities, Innovative ideas for modification.
 Motor Maintenance Manual - Prepared & published for best maintenance
practices and skill developments of Essar employees and technicians.
 Responsible For Reliability of HT/LT equipments –
Electrical Condition Monitoring activity and power lab - Develop & established for testing of
Relays and circuit breakers, CT/CVT, scheduled Thermogrphic inspection of Electrical
feeders, motors & transformers electrical object, and follow up for compliance for reduction
in breakdown.
 Initiated for revenue generation from external companies by providing services like
advance testing 220KV transformers, CT/CVT/LA, pre-commissioning and commissioning
testing of HT,LT motors, transformer oil testing.
 Co-ordinate and follow up for compliance with all departments/plants for electrical
equipments on the basis condition monitoring reports(RCM) for reliability of equipments.
 Auditing various electrical installations and participated in various investigation committees
on breakdown and accidents in plant.
Page - 3 - of 4
- 3 - | P a g e
CURRICULAM VITE
 Co-ordinate & arrangement of Third party inspection, certification of cranes across all
plant.. Inspection/auditing of EOT cranes as internal auditor, Follow-up compliance, support
for cranes maintenance.
 Support for commissioning of Blast furnace plant & 19 MW Power plant and other projects,
providing support services as Central Electrical maintenance to all dept/plant in Essar steel.
 Monthly report & MIS. Material planning, technical specification, generating PR/PO by SAP
system and Vendor selection & TR. Prepare & monitoring Cape/open Budget of Dept.
 Support senior management for optimize material procurement and reducing cost of
repairing by developing in-house repair facilities.
 As Safety coordinator and plant safety engineer for dept., improving safety work practices by
planning & execution to various safety promotion & training activity for achieving monthly
target of safety index.
 As core member of Integrated Management System (ISO 14001, OHSAS 18001, and ISO
50001) co-ordinate, implemented & maintain IMS in dept., handling various projects on
FMEA, QC’s, 5’S with team.
 Cross functioning of departments mentoring Electronic card repairing, instrumentation
calibration and repairing activity. Coordinate with govt. agency for annual stamping of weigh
scales and weigh bridges.
 Ensuring continuous development of subordinate through various technical and safety
trainings, formulate action plan improving their performance.
 Winning awards for Zero incident from last 4 years & Runner-up for best safety practices in
dept.
2) About 6½ years, from 13/03/2000 to 01/08/2006 worked with
“Nava Sheva International Container Terminal” Ltd. (P&O ports),Sheva, Navi-Mumbai,
As an Executive – Electrical (From 2000 to 2006)
 As shift-in charge, attending break-down, PM schedule, day to day activity planning.
 Daily & monthly break-down report, analysis of break-down trends, generating &
implementing action for break-down reduction.
Maintenance & Trouble-shooting of Modern container handling heavy duty ports cranes of 55
Ton Capacity like -
 Rail Mounted Quay Cranes (8 nos.) – High speed container handling cranes having Siemens
make digital DC Drives and 135U PLC control system, D.C. Motors, 3.3 KV.
 RTG & RMGC Cranes (30 nos.) having Siemens PLC 115U, Digital AC, Drives, AC motors,
600 KVA Generators, Load measuring & Hydraulic system.
 33kv sub-station having Generators up to 1250KVA, Transformers, VCB, SF6, ACB & their
various switch-gear & protection relays.
3) 2 years worked in “Hindustan construction” Co. LTD. as an Electrical Engineer in
Mumbai-pune Exp. Way project. (From 1998 to 2000)
Installation, commissioning & maintenance of:-
- 300TPH Crushing plant, Automatic Batching plant, compressor, Chilling Plant.
- 2200 KVA Sub-station, Generators & Utility equipment.
- Co-ordination with electricity board for billing & inspector for approval.
4) 2 years worked with “NGDA Electomechanical” Ind. (P) LTD., Nagpur
as an Electrical Engineer. (From 1996 to 1998)
- Manufacturing of Electrical panels like PCC, MCC, Relay panels & Control panels.
- Testing of ACB & their protection system, Motor protection & over current relays.
Page - 4 - of 4
- 4 - | P a g e
CURRICULAM VITE
13. Professional Training Acquired:
1) Certificate Course in Siemens PLC, Programmable Controller Simatic S5 &
Vector control drive, Siemens Plant, Kalawa, Thane.
2) “Testing of Transformer oil” at CPRI, Bangalore.
3) Training on ISO 50001 & Internal auditor by quality growth service.
4) ISO 17025 Quality Management system (NABL) and internal auditor.
5) Training on Integrated Management System (ISO 9001,14001,18001), TPM,
Material Management, problem solving.
6) Certified course in Testing, Examination of Lifting machines, Tackles, pressure vessels,
Lifts & Hoists organized by National safety councils.
7) Certified Plant HSE Engineer of Essar Steel
8) Certificate Course in Fire Prevention & Fire Fighting by Director General of Shipping
(Govt. of India) at Training Ship Rahaman.
14. Knowledge sharing session regularly delivered on following topics –
1) Electrical Condition Monitoring of Transformers & HT Motors various departments
2) Transformer oil testing & DGA analysis and case studies to various departments
3) Motor maintenance skill development program for associates & trainees.
4) Crane safety & maintenance practices.
5) Energy Efficient Motors.
15. Conference –
Participated in conference on “Moving towards world class Reliability & Maintenance
Management” and presented Paper on “Reliability improvements through
Condition Monitoring of HT equipments” in “Innovation in Maintenance management
award” organized by ARMM forum (Asset & Reliability Maintenance Management forum).
16. Other Information :
Present CTC Drawn : 17 .50 Lakhs / Annum
Notice period : 1 Months
Native Place : Nagpur, Maharashtra
The above information is correct & true to best of my knowledge.
Place : SURAT
Date : 15th NOV. 2015. (PRAVEEN D. CHANNE)

More Related Content

What's hot (20)

Nstark 2015
Nstark 2015Nstark 2015
Nstark 2015
 
Cv (5) converted
Cv (5) convertedCv (5) converted
Cv (5) converted
 
Bhushan warghane 1_
Bhushan warghane 1_Bhushan warghane 1_
Bhushan warghane 1_
 
BE-ELECTRICAL SENIOR TESTING AND COMMISSIONING ENGINEER
BE-ELECTRICAL SENIOR TESTING AND COMMISSIONING ENGINEERBE-ELECTRICAL SENIOR TESTING AND COMMISSIONING ENGINEER
BE-ELECTRICAL SENIOR TESTING AND COMMISSIONING ENGINEER
 
resume krishna electrical engineer
resume krishna electrical engineerresume krishna electrical engineer
resume krishna electrical engineer
 
Mohamed_Saad
Mohamed_SaadMohamed_Saad
Mohamed_Saad
 
Mr DD update resume
Mr DD update resumeMr DD update resume
Mr DD update resume
 
bala.1
bala.1bala.1
bala.1
 
bala.1
bala.1bala.1
bala.1
 
Kumar RESUME
Kumar RESUMEKumar RESUME
Kumar RESUME
 
Satish_Reddy_resume
Satish_Reddy_resumeSatish_Reddy_resume
Satish_Reddy_resume
 
Ahmed CV 2016
Ahmed CV 2016Ahmed CV 2016
Ahmed CV 2016
 
Resume_Dipti Ranjan Rout
Resume_Dipti Ranjan RoutResume_Dipti Ranjan Rout
Resume_Dipti Ranjan Rout
 
SOURABH SONI
SOURABH SONISOURABH SONI
SOURABH SONI
 
Vimal cv
Vimal cv Vimal cv
Vimal cv
 
Alvin Eaton NEW 1 (3)
Alvin Eaton  NEW 1 (3)Alvin Eaton  NEW 1 (3)
Alvin Eaton NEW 1 (3)
 
Mahmood Hasan Resume 2
Mahmood Hasan Resume 2Mahmood Hasan Resume 2
Mahmood Hasan Resume 2
 
sanjog navandars
sanjog navandarssanjog navandars
sanjog navandars
 
UPDATED CV-1
UPDATED CV-1UPDATED CV-1
UPDATED CV-1
 
Whitted v 2015 (1) (1)
Whitted v 2015 (1) (1)Whitted v 2015 (1) (1)
Whitted v 2015 (1) (1)
 

Similar to CV- Praveen Channe (15NOV 2015) (20)

CV-VP-KEMYA
CV-VP-KEMYACV-VP-KEMYA
CV-VP-KEMYA
 
Resume electrical engineer- for oil & gas
Resume  electrical engineer- for oil & gasResume  electrical engineer- for oil & gas
Resume electrical engineer- for oil & gas
 
Resume
ResumeResume
Resume
 
SAGAR RESUME
SAGAR RESUMESAGAR RESUME
SAGAR RESUME
 
Sharma Resume
Sharma ResumeSharma Resume
Sharma Resume
 
Sharma Resume
Sharma ResumeSharma Resume
Sharma Resume
 
SRao_cv
SRao_cvSRao_cv
SRao_cv
 
Resume 25.09.15
Resume 25.09.15Resume 25.09.15
Resume 25.09.15
 
Raju cv
Raju cv Raju cv
Raju cv
 
dinesh.Resume.new (2)
dinesh.Resume.new (2)dinesh.Resume.new (2)
dinesh.Resume.new (2)
 
CV Nagashiva
CV Nagashiva CV Nagashiva
CV Nagashiva
 
Tim Phillips
Tim PhillipsTim Phillips
Tim Phillips
 
T.chandramouli O & M_ele
T.chandramouli O & M_eleT.chandramouli O & M_ele
T.chandramouli O & M_ele
 
T.chandramouli O & M_Electrical
T.chandramouli O & M_ElectricalT.chandramouli O & M_Electrical
T.chandramouli O & M_Electrical
 
Radhe_Resume
Radhe_ResumeRadhe_Resume
Radhe_Resume
 
MUHAMMAD NADEEM CVWITH PICTURE
MUHAMMAD NADEEM CVWITH PICTUREMUHAMMAD NADEEM CVWITH PICTURE
MUHAMMAD NADEEM CVWITH PICTURE
 
SuryaMohan_Resume_2016
SuryaMohan_Resume_2016SuryaMohan_Resume_2016
SuryaMohan_Resume_2016
 
SuryaMohan_Resume_2015
SuryaMohan_Resume_2015SuryaMohan_Resume_2015
SuryaMohan_Resume_2015
 
Graduate Electrical Engineer having 6.6 Years exprience in renewable energy &...
Graduate Electrical Engineer having 6.6 Years exprience in renewable energy &...Graduate Electrical Engineer having 6.6 Years exprience in renewable energy &...
Graduate Electrical Engineer having 6.6 Years exprience in renewable energy &...
 
RAM-CV
RAM-CVRAM-CV
RAM-CV
 

CV- Praveen Channe (15NOV 2015)

  • 1. Page - 1 - of 4 - 1 - | P a g e CURRICULAM VITE 1. NAME : PRAVEEN DINKAR CHANNE. 2. DATE OF BIRTH : 8TH January 1974. 3. QUALIFICATION : B.E. in Electrical Engineering. 4. TOTAL EXPERIENCE : 19 Years. , Working as DGM Reliability Management through Electrical condition monitoring (RCM) of electrical equipments i.e. Health Diagnostic testing of Transformers, HT Motors and switchgears etc., Transformer oil testing Lab (NABL accredited). Central Motor overhauling workshop, Central Electrical maintenance support services to all plant/dept of Essar steel i.e. SMP,HBI, HSM, CSP, CRM, Utility, BF & Sinter, ASU, power plants etc. Support to commissioning blast furnace and other projects. Maintenance of Heavy duty ports Cranes & EOT. Maintenance of AC/DC Drives, PLC’s etc., Erection, Commissioning, maintenance & testing of LT/HT switch-gears, Sub-stations, Generators, Material handling, crushing & Batching plants. 5. EDUCATIONAL QUALIFICATION : a) Bachelor of Engineering in Electronics & Power (Electrical Engineering) from Nagpur University, in May-1995 with First class b) Diploma in Electrical Engineering with First Class in B.T.E. Maharashtra, in 1992. c) Post graduate Diploma in Management from I.G.N.O.U. in Jun- 2003. 6. PROFESSIONAL CERTIFICATION : Certified Energy Manager from bureau of energy efficiency (2012) 7. LICENCE : Electrical supervisory license holder of Maharashtra state. 8. COMPUTER PROFICIENCY : MS-Office, SAP operation. 9. PERMANENT ADDRESS : V- 55, Narendra Nagar, Nagpur- 440 015, Mob. No. 09561003082 10. ADDRESS FOR : F-3/13, Nandniketan, Essar Township, CORRESPONDENCE Surat-Hazira Road, Hazira, Surat, Gujarat – 394 270. Mob. No. 09879101056;9586227409 11. E-mail ID : pchanne@yahoo.com
  • 2. Page - 2 - of 4 - 2 - | P a g e CURRICULAM VITE 12. DETAIL EXPERIENCE : 1) From 04/09/2006 working with “ESSAR STEEL INDIA LTD”. , Hazira, Surat. As Deputy General Manager- Electrical, Central Electrical & Instrumentation Dept.(CEID), Heading all Electrical activity of Central Dept. (from 2006 to till date)  Central Electrical maintenance (CMD) services to all plants/depts. of Essar steel i.e. SMP,HBI, HSM, CSP, CRM, Utility, Blast Furnace & Sinter, ASU, power plants etc.  Supports to depts. for measure/calculate the energy efficiency of various electrical system like transformers/motors etc. & Energy saving projects.  Electrical equipments “Reliability Condition Monitoring” and health assessment - Plan and executing for optimum monitoring of all electrical equipments and suggest predictive maintenance of equipments, co-ordinate, interpret and provide solutions in context with the Electrical HT equipments activities of all units of Essar steel, Hazira.  Responsible for Reliability of 460 transformer of Essar complex, Hazira  “Transformer oil Testing Lab” - Developed and established for DGA & General Test, its analysis & interpretation of DGA for more than 1000 sample annually, for quality assurance acquired NABL accreditation of Transformer oil Testing Lab (NABL certificate no. : T2286).  Transformer Health Diagnostic testing & Condition Monitoring - facility developed & established for transformers, CT/CVT up to 220KV of Essar complex.  As Transformer Club leader – Provided solutions and Co-ordination for reliability of transformers through best maintenance practices to various Dept. and sharing MIS on transformers through monthly club meeting.  Responsible for Reliability of 450 HT motors of Essar complex, Hazira  HT Motors & Generators Health Diagnostic & Condition Monitoring- facility developed & established for Essar complex by setup various specialize testing facility.  Established & handling “Centralized Motor Workshop” for AC/DC & HT Motors.  Main achievement – Highest capacity 2.9MW HT motor & 600KW LT slip ring shear motor overhauled, motor leads brazing, motor Insulation quality improvement testing after overhauling confirming through various testing like tan delta & capacitance test etc.  Support for Shutdown maintenance of AC/DC motor for different Dept/plants.  As Motor Club leader – Identify route cause of motor failure and degradation motors, provided solution for reliability of motors and sharing the problem in various motors across complex through Motor club. Co-ordinate with store and depts. for standardization & inventory control of motors. Ensuring implementation of best maintenance practices & cost reduction activities, Innovative ideas for modification.  Motor Maintenance Manual - Prepared & published for best maintenance practices and skill developments of Essar employees and technicians.  Responsible For Reliability of HT/LT equipments – Electrical Condition Monitoring activity and power lab - Develop & established for testing of Relays and circuit breakers, CT/CVT, scheduled Thermogrphic inspection of Electrical feeders, motors & transformers electrical object, and follow up for compliance for reduction in breakdown.  Initiated for revenue generation from external companies by providing services like advance testing 220KV transformers, CT/CVT/LA, pre-commissioning and commissioning testing of HT,LT motors, transformer oil testing.  Co-ordinate and follow up for compliance with all departments/plants for electrical equipments on the basis condition monitoring reports(RCM) for reliability of equipments.  Auditing various electrical installations and participated in various investigation committees on breakdown and accidents in plant.
  • 3. Page - 3 - of 4 - 3 - | P a g e CURRICULAM VITE  Co-ordinate & arrangement of Third party inspection, certification of cranes across all plant.. Inspection/auditing of EOT cranes as internal auditor, Follow-up compliance, support for cranes maintenance.  Support for commissioning of Blast furnace plant & 19 MW Power plant and other projects, providing support services as Central Electrical maintenance to all dept/plant in Essar steel.  Monthly report & MIS. Material planning, technical specification, generating PR/PO by SAP system and Vendor selection & TR. Prepare & monitoring Cape/open Budget of Dept.  Support senior management for optimize material procurement and reducing cost of repairing by developing in-house repair facilities.  As Safety coordinator and plant safety engineer for dept., improving safety work practices by planning & execution to various safety promotion & training activity for achieving monthly target of safety index.  As core member of Integrated Management System (ISO 14001, OHSAS 18001, and ISO 50001) co-ordinate, implemented & maintain IMS in dept., handling various projects on FMEA, QC’s, 5’S with team.  Cross functioning of departments mentoring Electronic card repairing, instrumentation calibration and repairing activity. Coordinate with govt. agency for annual stamping of weigh scales and weigh bridges.  Ensuring continuous development of subordinate through various technical and safety trainings, formulate action plan improving their performance.  Winning awards for Zero incident from last 4 years & Runner-up for best safety practices in dept. 2) About 6½ years, from 13/03/2000 to 01/08/2006 worked with “Nava Sheva International Container Terminal” Ltd. (P&O ports),Sheva, Navi-Mumbai, As an Executive – Electrical (From 2000 to 2006)  As shift-in charge, attending break-down, PM schedule, day to day activity planning.  Daily & monthly break-down report, analysis of break-down trends, generating & implementing action for break-down reduction. Maintenance & Trouble-shooting of Modern container handling heavy duty ports cranes of 55 Ton Capacity like -  Rail Mounted Quay Cranes (8 nos.) – High speed container handling cranes having Siemens make digital DC Drives and 135U PLC control system, D.C. Motors, 3.3 KV.  RTG & RMGC Cranes (30 nos.) having Siemens PLC 115U, Digital AC, Drives, AC motors, 600 KVA Generators, Load measuring & Hydraulic system.  33kv sub-station having Generators up to 1250KVA, Transformers, VCB, SF6, ACB & their various switch-gear & protection relays. 3) 2 years worked in “Hindustan construction” Co. LTD. as an Electrical Engineer in Mumbai-pune Exp. Way project. (From 1998 to 2000) Installation, commissioning & maintenance of:- - 300TPH Crushing plant, Automatic Batching plant, compressor, Chilling Plant. - 2200 KVA Sub-station, Generators & Utility equipment. - Co-ordination with electricity board for billing & inspector for approval. 4) 2 years worked with “NGDA Electomechanical” Ind. (P) LTD., Nagpur as an Electrical Engineer. (From 1996 to 1998) - Manufacturing of Electrical panels like PCC, MCC, Relay panels & Control panels. - Testing of ACB & their protection system, Motor protection & over current relays.
  • 4. Page - 4 - of 4 - 4 - | P a g e CURRICULAM VITE 13. Professional Training Acquired: 1) Certificate Course in Siemens PLC, Programmable Controller Simatic S5 & Vector control drive, Siemens Plant, Kalawa, Thane. 2) “Testing of Transformer oil” at CPRI, Bangalore. 3) Training on ISO 50001 & Internal auditor by quality growth service. 4) ISO 17025 Quality Management system (NABL) and internal auditor. 5) Training on Integrated Management System (ISO 9001,14001,18001), TPM, Material Management, problem solving. 6) Certified course in Testing, Examination of Lifting machines, Tackles, pressure vessels, Lifts & Hoists organized by National safety councils. 7) Certified Plant HSE Engineer of Essar Steel 8) Certificate Course in Fire Prevention & Fire Fighting by Director General of Shipping (Govt. of India) at Training Ship Rahaman. 14. Knowledge sharing session regularly delivered on following topics – 1) Electrical Condition Monitoring of Transformers & HT Motors various departments 2) Transformer oil testing & DGA analysis and case studies to various departments 3) Motor maintenance skill development program for associates & trainees. 4) Crane safety & maintenance practices. 5) Energy Efficient Motors. 15. Conference – Participated in conference on “Moving towards world class Reliability & Maintenance Management” and presented Paper on “Reliability improvements through Condition Monitoring of HT equipments” in “Innovation in Maintenance management award” organized by ARMM forum (Asset & Reliability Maintenance Management forum). 16. Other Information : Present CTC Drawn : 17 .50 Lakhs / Annum Notice period : 1 Months Native Place : Nagpur, Maharashtra The above information is correct & true to best of my knowledge. Place : SURAT Date : 15th NOV. 2015. (PRAVEEN D. CHANNE)