1. Muhammad Nabeel Aslam
Electrical Engineer (Power)
House #21 Canal Colony Bahawalpur,Pakistan
Email: dear.nabeel@yahoo.com
Mob: +923017467175
+92-322-6558827
Career Objective
To work in the dynamic, team oriented, competitive and cooperative environment in a
reputable organization, where there is maximum chance of learning and grow as a proficient,
innovative and committed person
I am looking for a position, where I can learn and improve my engineering knowledge and
where I can utilize my engineering, electrical, power, communication skills,
telecommunications and interpersonal skills for the growth of my company and career.
Education
• B.Sc. Electrical Engineering (Power System) 2012
The Islamia University of Bahawalpur Pakistan
• D.A.E (Electrical) 2007
Asian college of Technology Bahawalpur
• Matriculation (Science) 2004
Board of Intermediate and Secondary Education Bahawalpur Pakistan.
Membership
• Pakistan Engineering Council (PEC) Membership No. 34497
• International Association of Engineers (IAENG) Membership No. 121073
• IEEE (Institute of Electrical and Electronics Engineers)
Certifications
• First Aid And Fire Fighting Certification
Technical & Other Software skills
• LMT
• OMT 49,50,52
• Mini link craft 2.5
• Delta Rectifier software
• Emerson Rectifier software
• Etap Electrical Software
• Electronic Work Bench
• Microsoft Office 2015, Microsoft Visio , Microsoft Project
• Lighting Design Software
2. Work Experience
Zhongxing Telecom Pakistan(ZTE) (Pvt) Ltd 中 兴 通 讯 巴 基 斯 坦 子 公 司 (Mobilink
Swap Project)from(25-jul-2015-Till Now)
Working as a RAN Engineer in ZTE, My responsibilities includes,
Swap Ericsson (6000 family to ZTE8910 SDR cabinet).
Configure SDR with MO files and Integrate site by verifying media through ping test
by cola soft.
BSS & Transmission System Testing Support
BSS & TXN Services
Soft and Hard Expansion’s
Deeply understanding of RRU cascading (8863,8881 for GSM,DCS and 3G).
Shifting of TN from Ericsson 6000 cabinets to ZTE 8910 and verify its RSL.
Antenna’s audit according to its Electrical, Mechanical Tilts, Azimuth and Heights.
Troubleshoot all internal and external site alarms also verify to Customer NOC.
Supervise site quality indoor, outdoor according to customer standard point of view
upload data at EPMS.
Troubleshoot site snags before customer ATP visit.
Prepare PAT/FAC documents.
ATP OF SITES With customer
Mobiserve Pvt. Ltd(Mobilink Operation)from( 01-0ct2012-25-Jul2015)
Worked asBSS & Transmission Engineer
Analyzing and Supervision of all Transmission related issues to overcome the outages.
Making cross connection of E1 from end to end.
Health checking of all types of Links.
Analyzing and supervision of All BSS issues to minimize the outage factor.
Analyzing and supervision of all non-Telco issues.
Close monitoring of sites fueling issues.
Activation & testing of GLO.
Auditing of CM/PM activities to make sure no pending activity should be at site.
To train them to do a quality PM.
To arrange all the documentations & database of my work.
To provide all the technical support to my teams.
Coordinating with customer to fulfill their network need.
Daily update of NAR &QoS related issues & daily updated reporting of the tasks to the
client & the management.
Arrange the supply chain & manage daily activity.
Follow up of down sites/Cells
3. Daily Regional KPI Analysis and other Network effecting reports
Get the Feedback from Regional Teams and Satisfy the Costumer
More than 350 Sites of PMCL Monitoring
Escalation of Trouble Ticket and follow up to close the issue ASAP
Ericsson RBS6000 Family
Commissioning and configuration of Ericsson Radio Base Station RBS 6000
family.
Conduct troubleshooting of alarms that occurred in RBS 6000 Series (e-Node B)
during malfunction of equipment.
Commissioning and configuration of Ericsson Radio Base Station RBS 6000
family.
Conduct troubleshooting of alarms that occurred in RBS 6000 Family during
malfunction of equipment such as DUG,RUS, RRU and any other alarm that occur
from the Radio Base Station
ERICSSON TRANSMISSION
Supervising and doing installations of Ericsson Minilinks E Classic Nodes, Traffic
Nodes and High Capacity Links.
Acceptance of TN, HC, Classic Link E according to Ericsson standards.
Commissioning of Minilink E, Traffic Nodes (2p, 6p, 20p) and HCs.
Representing during Procedure Acceptance Test of Ericsson Minilinks as per
Ericsson Protocol and performing BER Tests electrical and optical to get links
accepted.
Performing Traffic Routings on Minilink E and Traffic Nodes and doing necessary
hard patching, if required, according to transmission plan.
Trouble shooting Radios and Modems in case of any operational problem or
degraded RSL.
Performing software upgrade of Traffic Nodes and High capacity Links.
Responsibilities:
• all documentation and database of cell sites.
• Provide technical support to the team for better feedback
• Supervision of all the indoor and outdoor (feeder cables and groundings of the cell
sites.
• Installation and fault tracing/troubleshooting of microwave link 2p,6p,20p and CN.
• Co-ordination with operator/vendors/subcontractor for fault identification and
rectification, problem synthesis & reporting
• Solving all the path balance related issues of OMT radios by countering the reflection
and calibrating either RX or TX path depending upon uplink or downlink losses.
• Identifying and resolving the sector swapping issues in the BTS cell sites
• Monitoring the stats of the problematic BTS radios and troubleshooting the issues.
• Identification of BSS hardware problems in field by monitoring all the alarms
• To clear all kinds of EAS and IAS alarms of Ericsson BTS daily basis.
• Perform health check of BSS Equipment and make monthly Equipment performance report.
• Performing offline commissioning of Ericsson OMT.
4. • Solving of VSWR issue using site master.
• Installation of mini links 2p, 6p,20p and CN
• E1 patching, Alarm patching. Alarms installation.
• Site survey and Quality checking of cell sites.
• Alarms rectification with co-ordination of NOC.
• Ensure Preventative maintenance.
• Ensure Corrective maintenance
• Supervise the Installations Jobs
• Managing the full deployment of the Direct and Indirect manpower to achieve the
targets successfully.
• Generally responsible for implementations and monitoring of all electrical related
works at site.
• Planning-Staffing-Organizing
• Coordinates with Client / Consultant’s representatives for any site instructions and
inspection of works.
• Submitting daily, weekly Reports to Client and weekly, monthly updated schedule
• Ensure the QA/QC Requirements.
• Interprets construction drawings and studies the contract documents and applicable
standards or specifications prior to execution of any jobs.
• Submits site daily reports, inspection requests, estimates and all applicable monitoring
reports on regular basis or as required.
• Ensures that all the works done are in accordance with the approved construction
drawings, contract documents, project specifications, and all applicable standards
whether local, national or international standards. Carry out the monitoring &
maintenance, fault rectification & Troubleshooting for Genset
• Supervise the installation of New Gensets
• Carry out the testing commissioning and troubleshooting the faults of Ericsson and
Alcatel BTS.
• Troubleshooting the internal and external alarms of Ericsson RBS 6301, RBS6201 and
RBS6101
• Commissioning, installation and trouble shooting of all kinds of rectifier and properly
patching of all external alarms.
• Responsible for trouble shooting of E1 at BTS up to traffic.
• Trouble Shooting and faulty monitoring of all types of rectifiers
Delta,Emerson,altec,soft power and flat pack power system.
• Troubleshooting of VSWR and antennas issues.
• Properly patching all PCM through microwave links.
• To manage and train the teams for PM and CM purpose.
Final Year Project
Design of 220 KV Sub-station
• 3d Modeling of 220kv Substation
5. • Detail Study & Construction of 220kv substation
Physical Wooden and Electrical Model Representation
Interests
Internet research, volunteer work, technical magazine reading, and maintenance wizard at
home in spare time.
Personal Information
• Father’s Name: Muhammad Aslam
• Date of birth: 10 April, 1989.
• Marital Status: Married
• N.I.C No: 31202-6511770-5
6. • Detail Study & Construction of 220kv substation
Physical Wooden and Electrical Model Representation
Interests
Internet research, volunteer work, technical magazine reading, and maintenance wizard at
home in spare time.
Personal Information
• Father’s Name: Muhammad Aslam
• Date of birth: 10 April, 1989.
• Marital Status: Married
• N.I.C No: 31202-6511770-5