3. Objective 4: University Library Conceptual Programming
Average gate access/day (2011-2012): 262 Observed Library Use - Individuals & Groups*
*2+ individuals working together
11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM Groups
900
750
600
No. of Individuals
450
12/5/11 – 5:00 PM; 121 individuals
300
150
0
11
1
1
11
1
11
11
11
11
11
1
1
12
12
12
12
12
01
01
01
01
01
20
20
20
20
20
20
20
20
20
20
20
20
,2
,2
,2
,2
,2
8,
9,
5,
,
2,
,
,
,
,
9,
,
6,
10
23
23
20
14
29
11
29
14
28
22
l2
p
ct
ov
b
ar
g
g
p
ct
ov
ov
c
c
n
n
b
Se
Fe
Ju
O
M
N
De
De
Ja
Ja
Au
Au
Se
Fe
O
N
N
Date proprietary and confidential
Golden Gate University SF Remodel Project - Phase 7: Master Planning & Programming MKTHINK 3
4. Objective 4: University Library Conceptual Programming
Existing Seat Count
Total Group Interaction Seats: 251
250
Total enrollment: 2,368
200
Non-law enrollment (hybrid, in-person): 1,526
Law enrollment: 842
No. of Individuals
150
Total seating: 927 (1:3)
University Library seating: 169 (1:14)
100 (44 carrels)
436 seats
Law Library seating: 491 (1:2)
General seating (incl. 40 Jessie): 267 (1:9)
50
Average class load: 725
0
8 AM 10 AM 12 PM 2 PM 4 PM 6 PM
Time
Plaza 2 3 4 5 6 Jessie
Data taken from 3/28/12 (W), 4/3/12 (Tu), 4/12/12 (Th)
proprietary and confidential
Golden Gate University SF Remodel Project - Phase 7: Master Planning & Programming MKTHINK 4
5. Objective 4: University Library Conceptual Programming
Seating Options
20% of average class load
Option 1 Option 2 Option 3
Collaborative: 21 (15%) Collaborative: 44 (30%) Collaborative: 80 (55%)
Collaborative
Individual: 44 (30%) Individual: 80 (55%) Individual: 21 (15%)
Group study room: 80 (55%) Group study room: 21 (15%) Group study room: 44 (30%)
Seats: 145
40% of average class load
Option 1 Option 2 Option 3
Collaborative: 44 (15%) Collaborative: 87 (30%) Collaborative: 160 (55%)
Individual: 87 (30%) Individual: 160 (55%) Individual: 44 (15%)
Group study room: 160 (55%) Group study room: 44 (15%) Group study room: 87 (30%)
Seats: 290
Individual
60% of average class load
Option 1 Option 2 Option 3
Collaborative: 65 (15%) Collaborative: 131 (30%) Collaborative: 239 (55%)
Individual: 131 (30%) Individual: 239 (55%) Individual: 65 (15%)
Group study room: 239 (55%) Group study room: 65 (15%) Group study room: 131 (30%)
Seats: 435
Group study room
proprietary and confidential
Golden Gate University SF Remodel Project - Phase 7: Master Planning & Programming MKTHINK 5
7. Objective 4: University Library Conceptual Programming
Print Volumes Projections
Current total print volumes: 74,810
Assumed growth rate per year: 0% (0 volumes)
Projected print volumes in 10 years: 68,810 (-6,000 volumes)
Reference collection (15%) 10,322 (520 SF of standard shelving required, excluding perimeter)
Circulating collection (85%) 58,489
proprietary and confidential
Golden Gate University SF Remodel Project - Phase 7: Master Planning & Programming MKTHINK 7
8. Objective 4: University Library Conceptual Programming
High-Density Book Storage Option: Multi-Level Standard Shelving
FLOOR 1
1,334 SF
Perimeter
FLOOR 2
1,334 SF
Number Unit Shelves Volumes SF per Total SF % of
SF per LF Collection
of Shelves Height Depth per LF unit required
Floor 1 6 82” 10’ 8 2.48 0.4 1,473
91%
Floor 2 6 82” 10’ 8 2.48 0.4 1,473
proprietary and confidential
Golden Gate University SF Remodel Project - Phase 7: Master Planning & Programming MKTHINK 8
9. Objective 4: University Library Conceptual Programming
High-Density Book Storage Option: Single Level Compact Shelving
FLOOR 1
1,334 SF
Perimeter
Number Unit Shelves Volumes SF per Total SF % of
SF per LF Collection
of Shelves Height Depth per LF unit required
Floor 1 7 84” 12’ 8 5.16 0.19 1,417 94%
proprietary and confidential
Golden Gate University SF Remodel Project - Phase 7: Master Planning & Programming MKTHINK 9
10. Objective 4: University Library Conceptual Programming
High-Density Book Storage Option: Multi-Level Compact Shelving
FLOOR 1
1,334 SF
Perimeter
FLOOR 2
1,334 SF
Number Unit Shelves Volumes SF per Total SF % of
SF per LF Collection
of Shelves Height Depth per LF unit required
Floor 1 6 82” 10’ 8 2.48 0.4 709
190%
Floor 2 6 82” 10’ 8 2.48 0.4 709
proprietary and confidential
Golden Gate University SF Remodel Project - Phase 7: Master Planning & Programming MKTHINK 10
11. Objective 4: University Library Conceptual Programming
Future Conceptual Organizational Model
Silence Noisy
Staff Lounge/
Workroom
Book
Instruction Room
Library Staff
Storage
Gathering/
Meeting/
Lounge/
Storage Individual &
Book Browsing
QUIET ZON E Reference/ Collaborative
Circulation Study Space
Desk
Individual
Learning Support
Study
Space
Services
Restrooms
Collaborative Study Rooms Collaborative Study Rooms
R EG UL AR AC C ES S EX TEN DED AC C ESS
proprietary and confidential
Golden Gate University SF Remodel Project - Phase 7: Master Planning & Programming MKTHINK 11