SlideShare a Scribd company logo
1 of 25
Download to read offline
Series 70 ePODs: Type-P
Static Transfer Switch → Transformer → Distribution
The Foundation Layer
Product Brochure
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
ePODs: Type-P STS/PDU Combination Increases Reliability and Operator Safety
LayerZero Power Systems designed the Series 70 ePODs: Type-P to provide switching between multiple sources and finger-
safe power distribution in an easy-to-deploy package. The ePODs: Type-P provides switching between two independent
power sources on the primary side of the transformer, while providing power distribution capabilities, featuring a solid-state
transfer switch on the primary side of the transformer. The Series 70 ePODs: Type-P provides the ability to transfer power
between two or three sources in quarter of an electrical cycle, while delivering that power to up to twelve sub-feed circuit
breakers or to branch circuit panel boards. The Finger-Safe SafePanel is IP-20, inspired by the reccomendations of NFPA-70E.
In addition, ePODs: Type-P includes Zen DPQM™, LayerZero’s Static Transfer Switch power quality monitoring system.
The LayerZero ePODs: Type-P PDU
Increases Operator Safety
Up to 12 CB positions
1200A SafePanel 1
Source 1
Input
Source 2
Input
480V, 3-phase, 3-wire
or
600V, 3-phase, 3-wire
202BC102BC
201BC101BC CNCN
NO NO
CB302CB301 NC NC
Up to 12 CB positions
1200A SafePanel 2
NCCB701 NO CB702
NCCB601 NO CB602
T620
TVSS620 SA620
120/208V, 3-phase, 4-wire
or
240/415V, 3-phase, 4-wire
TVSS601
Series 70 ePODs: Type-P
One Line Diagram
2 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
;; Optional Triple Modular Redundancy: TMR Contains Fully-Independent Control Paths With No Single Point-Of-Failure
;; Safe Bypass Procedure: Mechanical Bypass Interlock Eliminates Human Error When Performing Bypass Procedures
;; Voice Guided Bypass: Step-By-Step Instructions With Audio and Video Guidance To Assist Operators Through Bypass
;; Convection Cooling: Natural Convection-Cooled Heat Dissipation System is Maintenance-Free
;; Epoxy Coated Buswork: Maximizes Reliability By Eliminating The Possibility of Bus-To-Bus Faults
;; Silver Plated Terminals: Silver Has Excellent Conductivity To Provide Superior Electrical Performance and Reliability
;; Maintenance-Free Joints: Brazed Joints Are Permanent And Maintenance-Free, Maximizing Product Life
;; Machined Hardware: Machined Cap Screws and Engineered Disc Springs Maintain Constant Torque Throughout Product Life
;; Screw Thread Inserts: Prevents Screws From Loosening Under Vibration For Long-Term Reliability
;; Optical Fiber Based Controls: Eliminates Noise and Interference While Isolating Components from High Voltage
;; Serialized Critical Board Tracking: Critical Boards Are Serialized And Cataloged in an Active Database For Traceability
;; Transformer Vibration Isolation: Vibro-Elastic Pads to Absorb Vibrations from the Transformer
Reliability
LayerZero’s ePODs: Type-P Is Equipped Fully-Loaded
Safety
;; InSight™ IR Portholes: Bolted Connections & Critical Boards Can Be IR Scanned With the Dead-Front Doors Closed
;; Sectionalized Components: Isolated Sections That Can Be Safely De-Energized For Performing Maintenance
;; Polycarbonate Windows: Allows Critical Board LEDs To Be Viewed With The Dead-Front Door Closed
;; Front-Only Access: Installation and Maintenance Can Be Safely Performed Without Side or Rear Access
;; Dead Front Hinged Doors: Barrier To Provide A Safe Working Area With No Exposed Live Parts
;; SafePanel™ Distribution: NFPA-70E Inspired Finger-Safe Panel Board With No Exposed Live Parts
Connectivity
;; Ethernet Connectivity: Secure VPN Router Connects To Network For Advanced Remote Monitoring Capabilities
;; Modbus/TCP: Open Connectivity to Existing Monitoring Systems Without Proprietary Limitations
;; NTP Time Clock Synchronization: Facilitates Timeline-Based Logging For Post-Event Reconstruction
;; SNMP Connectivity: Permits Remote Management Via Simple Network Management Protocol
;; Real-Time Waveform Capture: Automatically Captures A Picture Of The Power Three-Cycles Before and After Every Event
;; Local Touch-Screen Interface: Password-Protected Color Touch-Screen GUI For Local STS Setup/Operation/Administration
;; Black-Box Forensics: eSTS Captures and Records All Events To Provide Vital Information In Root-Cause Analysis
;; Waveforms Automatically Emailed: Capability to Send Waveform Captures To Designated Individuals For Every Transfer
3 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
eSTS:
Size: 250 A, 400 A, 600 A, 800 A
Voltage: 480 V, 3-W; 600 V, 3-W
Redundancy:
• Triple Modular Redundant (TMR)
• Single Module Redundant (SMR)
• Output Switch: Redundant,
• Non-redundant
Transformer section:
Size: 150kVA; 225kVA; 300kVA; 400kVA; 500kVA
Type: Normal Efficiency, TP-1 high efficiency
Inrush: Low-inrush
Non-linear thermal rating:
K-9, K-13, K-20
Main Circuit Breaker Section:
MCB optional
Mounting: Fixed, Plug-In
Type:
• Molded Case Switch
65kA, 100kA
• Electronic Trip
65kAIC, 100kAIC
Accessories:
• CB Shunt-trip
120VAC, 24VDC
CB Position Indication:
• Open, Tripped, Closed
Distribution Section:
Sub-feed distribution
• 1200 A SafePanel
Up to six (6) 42-circuit, 225A or 400A panel boards
Equipment Layout
ePODs: Type-P Distribution
Supports Top or Bottom Exit,
Feeding Directly to Power Panels.
4 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
1
3
4 5
2
6
7
8
9
10
11
12
13
14
1615 16
17
18
19
20
1. Alarmed Doors
2. Hinged Dead Front Doors
3. Silver Plated Terminals
4. 15” Color Touch Screen GUI
5. Printed Bypass Instructions
6. Polycarbonate Window
7. InSight™ IR Portholes
8. Convection Cooled Heat Sinks
9. Staggered Gate Drive Arrangement
10. Epoxy Coated Buswork
11. Circuit Breakers
12. Redundant Power Supplies
13. Louvered Convection Cooled Intake
14. Transformer
15. Transformer Circuit Breaker
16. SafePanel™
17. SafePanel™ Shrouds
18. Universal Dead Front Door
19. Cable Organization Clips
20. Up to 12 Subfeed Circuit Breakers
Equipment Construction Detail
5 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
Distribution Configuration Options
Highly Configurable Distribution
The Series 70 ePODs: Type-P is available in a wide variety of
configurations. ePODs: Type-P is equipped standard with a
Static Transfer Switch, Transformer, and Distribution in an easy-
to-deploy package. Distribution options include up to four
42-circuit branch circuit breakers (168 total), and subfeeds.
Optional configurations include:
• Front-Only Distribution
• Front + 1-Side Distribution
• Front, Left, and Right
6 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
LayerZero ePODs: Type-P Reliability Overview
The LayerZero ePODs: Type-P Provides Many Dimensions of Reliability:
•	 Control System Reliability
•	 SMR (Single Module Redundancy, Standard)
•	 TMR (Triple Modular Redundancy, Optional)
•	 Control Power Supply Reliability
•	 Signal Reliability
•	 Operator Procedural Reliability
Gate Drive 1
Source 1 A
Gate Drive 2
Source 1 B
Gate Drive 3
Source 1 C
Gate Drive 4
Source 2 A
Gate Drive 5
Source 2 B
Gate Drive 6
Source 2 C
Source 1
Control
Source 2
Control
WAN Port
Fiber Optics
SCB 1
Single Module Redundancy (SMR) Reliability (Standard)
Single Module Redundancy is a cost-effective topology that provides
redundant power paths to mission-critical equipment. In SMR
systems, sources each have built-in triple redundancy of processors.
In addition, every phase is controlled with a separate gate drive
board.
LayerZero Single Modular Redundant topology is unique that it the
system is fail-safe, maintaining full switching functionality even if a
critical board were to fail.
Reliability Overview
7 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
Reliability Features: Triple Modular Redundancy (TMR) *Optional
eSTS TMR Triple Redundant Power Supply Architecture
Has All Redundancy Features of SMR Architecture, Plus:
Each STS has three independent sets of analog and digital data
acquisition and control systems. There is no direct communication
between the three systems. The three systems do not even share a
common system clock.
•	 Each control system acquires voltage and current data
independently
•	 Each control system determines whether a source is good/bad
independently
•	 Upon loss of a source, each control system makes decisions to
transfer independently
Each SCR pair is driven by three separate actuators (gate drives)
Even if an entire control path or its subcomponent were to fail; and
then if the active power source were to fail, the STS is designed to meet
its emergency transfer specifications. It is able to complete its mission
of transferring to the alternate source.
Gate Drive 1
Source 1 A
Gate Drive 2
Source 1 B
Gate Drive 3
Source 1 C
Gate Drive 4
Source 2 A
Gate Drive 5
Source 2 B
Gate Drive 6
Source 2 C
Source 1
Control
Source 2
Control
Source 1
Control
Source 2
Control
Source 1
Control
Source 2
Control
WAN Port
Fiber Optics
SCB 1
SCB 2
(TMR)
SCB 3
(TMR)
8 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
eSTS SMR Triple Redundant Power Supply Architecture
Divided into four (4) logical failure groups:
•	 System controls
•	 Source 1 gate drives
•	 Source 2 gate drives
•	 Peripherals.
The three (3) available source of power from which to supply control
power to each failure group are:
•	 Source 1
•	 Source 2
•	 STS Output.
LayerZero’s STS design incorporates twelve (12) power supplies (3
power sources x 4 failure groups.) The resultant control power topology
utilizes all possible power paths to the four logical STS failure groups;
and is the most comprehensive and redundant power supply system in
existence.
Reliability Features: Single Module Redundant (SMR) Redundancy
Peripherals
PS 1
S1 A-B
Source 1
A B C
Source 2
A B C
PS 4
S1 B-C
PS 7
S1 A-C
PS 10
S1 A-B
PS 3
S2 B-C
PS 6
S2 A-C
PS 9
S2 A-B
PS 12
S2 B-C
System Controls
Gate Drives,
Source 1
Gate Drives,
Source 2
GD 1 GD 3 GD 5
SCB 1 SCB 2
TMR Only
SCB 3
TMR Only
GD 2 GD 4 GD 6
PS 5
Out A-B
System Controls
PS 8
Out B-C
Gate Drives S1
PS 11
Out A-C
Gate Drives S2
PS 2
Out A-C
Peripherals
Output
Bus
A
B
C
eSTS SMR Triple Redundant Processors
•	 Separate/independent processors for Source 1, Source 2 and
Output power quality analysis
•	 If Source 1 processor malfunctions then system is able to be
commanded to transfer to Source 2; & vice versa.
•	 If main control system fails then STS continues to conduct power to
the load from the existing source of power. (However STS is unable
to transfer to the other source)
•	 Each phase of each source is controlled with a separate gate drive
circuit board.
S1 S2 Output
Gate
Drive 1
Gate
Drive 2
Gate
Drive 3
Gate
Drive 4
Gate
Drive 5
Gate
Drive 6
A B C A B C
Source 1 Transfer Control Source 2 Transfer Control
9 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
Fiber Optic Controls Increase System Reliability
Fiber optic based controls eliminate noise and interference, while
isolating components from high voltage.
Optical fiber allows service to be reliably connected, while protecting
the equipment.
In LayerZero’s ePODs: Type-P design, the gate drives (at Power Circuit
Voltage) recieve control signsals via optical fibers.
Reliability Features
10 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
No Fans, Dust Filters, or Fan Fuses
Fans and fan sensors are one of the most common components to fail.
For maximum uptime, Type-P systems do not contain any fans, dust
filters to change, or fan fuses to replace. The Series 70 ePODs: Type-P
utilizes a natural convection-cooled heat dissipation system.
The heat sink arrangement is staggered between sources and phases to
minimize the creation of extreme thermal gradients between heat sink
columns when conducting on one source or the other.
Reliability Features
Epoxy Coated Buswork
Our usage of epoxy coated buswork helps ensure safety, and makes the
system inherently more reliable by eliminating the possibility of bus-to-
bus faults.
Silver Plating
LayerZero utilizes silver plating on all bus joints and terminals to be
able to provide the highest performance. Silver has high conductivity
and low resistance - which makes for a great contact.
11 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
Mechanical Bypass Interlock
In order to minimize the possibility of operator error during equipment
bypass operations, LayerZero provides:
1.	 Interlocked breakers
2.	 Mechanisms to ensure that a source cannot be bypassed without
the STS on the correct source.
3.	 Safeguards to make certain that sources cannot be connected to
each other inadvertently.
4.	 A voice-prompted bypass procedure that guides the operator
through the sequence.
5.	 A step-wise pictorial & video presentation is provided on the
touch-screen display during bypass.
Reliability Features
Voice Guided Bypass
Operator error during maintenance bypass has been known to be
a reliability hazard. To help prevent operators from completing
the bypass procedure out-of-sequence, our product features a
voice prompted bypass procedure. This instructs the operator
in a step-by-step course of action of the process, with only one
operation per screen.
Visual and audio cues provide clear instructions on the bypassing
sequence, reducing the probability of operator error.
12 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
Vibration Isolation Damper Mounts
Transformers in the Series 70: ePODs Type-P Power Distribution
Unit are equipped with vibration isolation damper mounts, helping
to reduce the amount of vibration and noise that originates from
transformers, ultimately leading to a higher reliability of electrical
and mechanical connections over the life of the product.
Sectionalization Maximizes Operator Safety
Operators are well-protected from exposed connections. Normal
operator sections (breakers/switches) are physically separated
from the power electronics and control electronics sections, so that
maintenance on a section can be safely performed. If maintenance is
required on a particular section, power can be bypassed to another
section to allow for safe repairs to be made.
Ease of Maintenance
13 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
InSight™ IR Portholes Permit Scanning of Bolted
Connections with Dead-Front Doors Closed
Strategically positioned IR-scan portholes to enable safe
thermal scanning of all bolted connections with the
deadfront closed, without exposing the operator to power
circuit voltage. Thermal scans can be done from the front –
without ever having to open the dead-front door.
The IR window swivels upward and unlocks with key-hole
access to reveal a mesh, allowing the operator to point-
and-shoot thermal cameras to obtain readings.
Elevated Transformer Mounting:
1. Eliminates parasitic plenum airflow
2. 4” rear clearance required
Ease of Maintenance
14 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
View Status LEDs and Distribution CB Positions With
Dead-Front Doors Closed
Our Series 70 product line was inspired by NFPA-70E, to help critical
facilities drastically reduce the risks of their energy distribution
systems.
Operators can view the status of diagnostic LEDs without exposure
to the energized power electronics section. In addition, SafePanel
circuit breaker positions can be viewed with the dead-front door
closed.
Modbus/TCP http:// through a
standard web browser
Network Time Protocol
(NTP) Compliant
Simple Network
Management Protocol
(SNMP)
Waveforms
Automatically Emailed
Series 70 ePODs:
Type-P
Standard
Ethernet
Dry Contacts
• Meters
• Alarms
• Meters
• Alarms
• Waveforms
• History/Event Log
• Diagnostics
• Summary Alarm
• On Source 1
• On Source 2
• Source 1 Available
• Source 2 Available
For Clock Synchronization
Ease of Maintenance/Connectivity Options
15 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
The LayerZero Finger-Safe SafePanel™
The Series 70 ePODs: Type-P features an IP-20, finger-safe panel
board, meaning that the opening will not allow ingress of ½” (12.5mm)
diameter probe, for maximum operator safety.
An arc can form as two live conductors are separated – such as the
removal of a circuit breaker from a panel board. The SafePanel design
ensures that a potential arc would be contained in the connection well
so that even if a branch breaker were to be removed, the arc would be
contained in the connection well.
Insulated with the components deeply isolated, removal of the breaker
is safe and easy.
The Protective Cover Is Removed The Breaker Is Inserted Into The Opening
The Breaker Snaps Into The DIN Rail The Breaker Is Secured With An Isolated,
Non Conducting Screw
Safety Features
16 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
Circuit Breaker Shrouds
LayerZero Series 70 ePODs: Type-P configured with 42-circuit
panel boards provide optional circuit breaker shrouds, designed
to eliminate exposure to live parts.
No Exposed Live Parts
LayerZero’s patent-pending Circuit Breaker Shrouds cover
exposed wiring, maximizing operator safety.
Wiring Without Shrouds Leaves Wiring Exposed Circuit Breaker Shrouds Maximize Operator Safety
Safety Features
17 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
The Breaker Is Inserted Into The SafePanel The Handle Is Unlocked
Screws Help Secure The Breaker For Maximum Safety, The SafePanel Has
Recessed Bus Work and Finger Safe Lattice.
Type-P 1200 A Circuit Breaker Installation Process
The LayerZero SafePanel™
The Series 70 ePODs: Type-P features an IP-20, finger-safe panel
board, meaning that the opening will not allow ingress of ½”
(12.5mm) diameter probe, for maximum operator safety.
An arc can form as two live conductors are separated – such as
the removal of a circuit breaker from a panel board. The SafePanel
design ensures that a potential arc would be contained in the
connection well so that even if a branch breaker were to be
removed, the arc would be contained in the connection well.
Insulated with the components deeply isolated, removal of the
breaker is safe and easy.
Safety Features
18 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
The Series 70 ePODs: Type-P is equipped with Zen SSQM (Static
Switch Quality Monitoring), an all encompassing monitoring
system with local and remote communications options.
From basic monitoring & alarm reporting, to advanced power
quality monitoring functionality, Zen SSQM provides a wide-range
of options to help you be aware, be vigilant, be proactive in your
quest to create a safe, stable and reliable operation.
Zen SSQM Provides Answers
Zen SSQM provides timestamped pictures of waveforms before and after events, providing information that enables facilities to go
back in time to methodically identify and correct the root causes of events. Zen actively captures power quality information at the
STS, PDU, and RPP - permitting thorough post-event analysis.
Product Name: Series 70 ePODs: Type-P
Unit Name: 500 + 1000 turn CTs
Serial #: 10028-34
Capture Reason: SQ Xfer 0-1
Captured By: scb122
Capture Time: 01-04-2016 6:53:08 PM
Microticks: 1449941
Phase A
Phase B
Phase C
Phase N
Phase G
Source 1 Volts L-L
Milliseconds
V
o
l
t
s
0
-200
200
-400
400
-600
600
-800
800
-1000
1000
Source 2 Volts L-L
Milliseconds
V
o
l
t
s
0
-200
200
-400
400
-600
600
-800
800
-1000
1000
Load Volts L-L
V
o
200
400
600
800
1000
Trigger Event
3 Electrical Cycles 3 Electrical Cycles
Waveform Capture of Current in a Source TransferPhase A
Phase B
Phase C
Power Quality Monitoring
19 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
A CT101 ACT102
ACT301
ACT620
CT1
A
CT2
A
CT4
A
CT3
A
V V
V
VV2
PQ
PQ
BM BM2BM1BM
CB101 CB102 CB601 CB602CB101
CB301
CB102
CB302
CB201 CB202
T620
SSW1 SSW2SSW1
SSW1
SSW2
SSW2
SSW2
SSW2
Subfeeds
A
V
PQ
Current Metering Point
Voltage Metering Point
Power Quality Metering Point
BM Branch Current Monitoring
Power Quality Monitoring
20 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
Zen SSQM Parameters Mains
Subfeeds or Branch
Circuits
Voltage Inputs and Output
Voltage
Frequency (Hertz)
Phase Rotation
Current Inputs
Current (Amps)
Current Fraction of Rating (Percent)
Current Imbalance (Percent)
Real Power (kilowatts)
Apparent Power (kilovolt-amperes)
Reactive Power (kilovolt-amperes reactive)
Power Factor
K Factor
Crest Factor
Alarms
Summary Alarm
Voltage (High, Low)
Overload
Thermostat (High, Low)
THD Over Limit
Frequency (Over, Under)
I A/B/C K-Factor Over Limit
Average K-Factor Over Limit
Incorrect Phase Rotation
Voltage Failure
I G1/G2 Over Ground Fault Limit
I G1/G2 Over Ground Overcurrent Limit
TVSS 1/2/3/4 Failure
Technical Specifications
All product specifications are subject to change without notice.
21 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
ePODs: Type-P Models with Withstand Ratings
208 V @ 240 V 480 V 575 V 600 V
225 A 65 kAIC; 50 kAIC 35kAIC; 25kAIC 10kAIC
250 A 200 kAIC; 150 kAIC;
100 kAIC; 65 kAIC
150kAIC; 100kAIC; 65kAIC;
35kAIC; 25kAIC;
100kAIC; 65kAIC; 35kAIC; 25kAIC; 18kAIC400 A 200 kAIC; 150 kAIC; 100
kAIC; 65 kAIC
600 A
200 kAIC; 100 kAIC; 65 kAIC800 A 100kAIC; 65kAIC; 50kAIC;
35kAIC
42kAIC; 35kAIC; 25kAIC; 20kAIC
Mechanical Characteristics
75kVA 150kVA 225kVA 300kVA 400kVA 500kVA 600kVA
Dimensions (side facing distribution) : 96”W x 88”H x 36”D
(2438 mm x 2235 mm x 914 mm)
108”W x 88”H
x 36”D
(2743 mm x
2235 mm x 914
mm)
125”W x 88” H x 36” D (3175 mm
x 2235 mm x 914 mm)
Dimensions (front facing distribution) : 120”W x 88”H x 36”D
(3048 mm x 2235 mm x 914 mm)
132”W x 88”H
x 36”D
(3353 mm x
2235 mm x 914
mm)
145”W x 88” H x 36” D (3683 mm
x 2235 mm x 914 mm)
Weight: 2000 - 3000 lbs (907 kg - 1361 kg) Varies on Configuration, Please Contact LayerZero Engineering
Heat Dissipation: Varies on Transformer Efficiency, Please Contact LayerZero Engineering.
Frame Construction Welded Frame
Electrical Connections Flexible Laminated Bus, Silver-Plated Solid Busbar
Color Textured Powder Coat White (RAL 7035), Blue (RAL 5017), Black, Custom
Seismic Floor Anchors Optional
Seismic Floor Stand Optional
Sectionalization Engineered Composite Insulation, Dead Front Doors
Electrical Characteristics
Static Transfer Switch
Number of Inputs 2, 3
eSTS Number of Output CBs 1, 2
Frequency 50 Hz, 60 Hz
Poles 3-pole, 4-pole
Phases 3 Phase, 3 Wire, 4 Wire + Ground
Neutral Rating 100%, 150%, 200%
eSTS Transfer Time Nominal 1/4- cycle for in-phase sources
eSTS Redundancy Single Module Redundancy, Triple Modular Redundancy (Optional)
eSTS Circuit Breaker Type Molded Case Switch (Standard), Electronic Trip (Optional)
Circuit Breaker Mounting Type Plug-In up through 600 A; Draw-out 800 A, 1200 A
eSTS TVSS Standard
EPO Optional
Subfeed Distribution
Distribution SafePanel™ Distribution
Technical Specifications
All product specifications are subject to change without notice.
22 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
Power Quality Monitoring
Power Quality Monitoring Technology Zen SSQM™ (Static Switch Quality Monitoring)
Waveform Capture Local Display, Remote Display via Web Browser, Waveforms Automatically Emailed
Voltmeter Input sources and Output, for each phase
Ammeter Input sources and Output, for each phase
Frequency Meter Both Sources
Real-Time Synchroscope Phase Angle Meter Between Sources
Metering Apparent Power, Real Power, Power Factor, Output Total Harmonic Distortion
Time Stamped Transfer Count From First Day Use, From Last Reset
CB Status Indicator Open/Closed/Tripped Circuit Breaker
Source Indicator Preferred Source
Phase Indicator When Any Two Sources Are Within Window
Power Path Indicator On Live Mimic
Operational Characteristics
Transfer Modes Automatic; Manual (via Preferred Source Selection)
Inrush Mitigation Technology Patented Dynamic Phase Compensation Algorithm (U.S. Patent 7,589,438 B2)
Cooling Convection Cooling
Cable Access Top/Bottom
Service Access Front Only
Bypass Interlock Mechanism Mechanical
Noise & Interference Isolation Optical Fiber in Critical Control Paths
IR Scan Port Type InSight™ IR Portholes
SCR Type Puck
Display Type 15” Color Touch Screen
Display Resolution 1024x768
Bypass Assistance Voice-Guided Bypass
Audio Bezel-Mounted Stereo Speakers
Languages English, French
Mimic Panel Digital
Setpoints Control Digital
Power Supplies Redundant (4 Failure Groups. Triple Redundant Supplies. 12 Power Supplies Provided.)
Standards Conformance: Static Transfer Switch
UL ETL Listed to UL 1008S
CSA ETL Listed to C22.22 No 107.
Standards Conformance: SafePanel Distribution
UL ETL Listed to UL 60950
CSA C22.2 No 29-M1989
Contact LayerZero for custom sizes and designs.
Notes:
1) Depth dimensions are valid for Sub-feed distribution. For panel board distribution, depth is 48".
2) Add 12" to width and Left side access for (5) or (6) 42-circuit panel boards
3) Rear access not required for installation; operation; and maintenance
Technical Specifications
All product specifications are subject to change without notice.
23 © Copyright 2016 LayerZero Power Systems, Inc.
Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P
Connectivity
Meters Local Display, Ethernet, Modbus/TCP, http via Web Browser (Non-Proprietary)
Alarms Local Display, Ethernet, Modbus/TCP, http via Web Browser (Non-Proprietary)
Summary Alarm Dry Contacts
Waveforms Local Display, Ethernet, http via Web Browser (Non-Proprietary)
History/Event Log Local Display, Ethernet, http via Web Browser (Non-Proprietary)
Diagnostics Local Display, Ethernet, http via Web Browser (Non-Proprietary)
Time Synchronization Network Time Protocol (NTP)
Number of Output Circuit Breakers
Number of Available SafePanel™ Slots 36
CB Rating Number of Slots Required
100 AF 2
250 AF 3
400 AF 3
400 AF 100% 6
800 AF 6
36 Total
Available Slots
1 Slot
2 Slots
3 Slots
6 Slots
Universal Dead FrontSafePanel™ Panel Board
Interchangeable
Plates Fit All CB Sizes
Blank Plates
All product specifications are subject to change without notice.
Technical Specifications
24 © Copyright 2016 LayerZero Power Systems, Inc.
LayerZero Power Systems, Inc.
1500 Danner Drive
Aurora, OH 44202 U.S.A.
© 2016 LayerZero Power Systems, Inc.
LayerZero Power Systems, LayerZero.com and the LayerZero logo are registered trademark of LayerZero.
All product specifications are subject to change without notice.
Learn more at www.LayerZero.com
Rev. 7/16 #16

More Related Content

What's hot

NFS2-3030
NFS2-3030NFS2-3030
NFS2-3030aescotom
 
NFS2-640
NFS2-640NFS2-640
NFS2-640aescotom
 
Networking
NetworkingNetworking
Networkingaescotom
 
LCD Annunciators
LCD AnnunciatorsLCD Annunciators
LCD Annunciatorsaescotom
 
LayerZero Series 70: eRPP-SL2 Slim Remote Power Panel
LayerZero Series 70: eRPP-SL2 Slim Remote Power PanelLayerZero Series 70: eRPP-SL2 Slim Remote Power Panel
LayerZero Series 70: eRPP-SL2 Slim Remote Power PanelLayerZero Power Systems, Inc.
 
Vacon nxl-brochure-bc00089 d-en
Vacon nxl-brochure-bc00089 d-enVacon nxl-brochure-bc00089 d-en
Vacon nxl-brochure-bc00089 d-enhongkiworld
 
NFS-320
NFS-320NFS-320
NFS-320aescotom
 
Applying Digital Isolators in Motor Control
Applying Digital Isolators in Motor ControlApplying Digital Isolators in Motor Control
Applying Digital Isolators in Motor ControlAnalog Devices, Inc.
 
QuickSilver Controls QCI-DS026 QCI-S2-IG
QuickSilver Controls QCI-DS026 QCI-S2-IGQuickSilver Controls QCI-DS026 QCI-S2-IG
QuickSilver Controls QCI-DS026 QCI-S2-IGElectromate
 
Advanced motion controls az25a20ddc
Advanced motion controls az25a20ddcAdvanced motion controls az25a20ddc
Advanced motion controls az25a20ddcElectromate
 
Advanced motion controls dzralte 060l080
Advanced motion controls dzralte 060l080Advanced motion controls dzralte 060l080
Advanced motion controls dzralte 060l080Electromate
 
Max485ds
Max485dsMax485ds
Max485ds____
 
Max 232
Max 232Max 232
Max 232Samarth
 
compliant charging controller for electric vehicle
compliant charging controller for electric vehiclecompliant charging controller for electric vehicle
compliant charging controller for electric vehiclecarloscostabr
 
Advanced motion controls dzralte 040l080
Advanced motion controls dzralte 040l080Advanced motion controls dzralte 040l080
Advanced motion controls dzralte 040l080Electromate
 
Advanced motion controls azbdc25a20
Advanced motion controls azbdc25a20Advanced motion controls azbdc25a20
Advanced motion controls azbdc25a20Electromate
 
Reducing Electrical Control Panel Size
Reducing Electrical Control Panel SizeReducing Electrical Control Panel Size
Reducing Electrical Control Panel SizeCMA/Flodyne/Hydradyne
 

What's hot (19)

NFS2-3030
NFS2-3030NFS2-3030
NFS2-3030
 
NFS2-640
NFS2-640NFS2-640
NFS2-640
 
Networking
NetworkingNetworking
Networking
 
LCD Annunciators
LCD AnnunciatorsLCD Annunciators
LCD Annunciators
 
LayerZero Series 70: eRPP-SL2 Slim Remote Power Panel
LayerZero Series 70: eRPP-SL2 Slim Remote Power PanelLayerZero Series 70: eRPP-SL2 Slim Remote Power Panel
LayerZero Series 70: eRPP-SL2 Slim Remote Power Panel
 
Vacon nxl-brochure-bc00089 d-en
Vacon nxl-brochure-bc00089 d-enVacon nxl-brochure-bc00089 d-en
Vacon nxl-brochure-bc00089 d-en
 
NFS-320
NFS-320NFS-320
NFS-320
 
Applying Digital Isolators in Motor Control
Applying Digital Isolators in Motor ControlApplying Digital Isolators in Motor Control
Applying Digital Isolators in Motor Control
 
Acb2
Acb2Acb2
Acb2
 
QuickSilver Controls QCI-DS026 QCI-S2-IG
QuickSilver Controls QCI-DS026 QCI-S2-IGQuickSilver Controls QCI-DS026 QCI-S2-IG
QuickSilver Controls QCI-DS026 QCI-S2-IG
 
Advanced motion controls az25a20ddc
Advanced motion controls az25a20ddcAdvanced motion controls az25a20ddc
Advanced motion controls az25a20ddc
 
Advanced motion controls dzralte 060l080
Advanced motion controls dzralte 060l080Advanced motion controls dzralte 060l080
Advanced motion controls dzralte 060l080
 
Max485ds
Max485dsMax485ds
Max485ds
 
Max 232
Max 232Max 232
Max 232
 
compliant charging controller for electric vehicle
compliant charging controller for electric vehiclecompliant charging controller for electric vehicle
compliant charging controller for electric vehicle
 
Advanced motion controls dzralte 040l080
Advanced motion controls dzralte 040l080Advanced motion controls dzralte 040l080
Advanced motion controls dzralte 040l080
 
Advanced motion controls azbdc25a20
Advanced motion controls azbdc25a20Advanced motion controls azbdc25a20
Advanced motion controls azbdc25a20
 
Reducing Electrical Control Panel Size
Reducing Electrical Control Panel SizeReducing Electrical Control Panel Size
Reducing Electrical Control Panel Size
 
Cfs0065 ccat-r1-4 part7
Cfs0065 ccat-r1-4 part7Cfs0065 ccat-r1-4 part7
Cfs0065 ccat-r1-4 part7
 

Similar to Reliable Power Distribution and Switching

LayerZero 4-Pole eSTS Static Transfer Switch with SafePanel Distribution
LayerZero 4-Pole eSTS Static Transfer Switch with SafePanel DistributionLayerZero 4-Pole eSTS Static Transfer Switch with SafePanel Distribution
LayerZero 4-Pole eSTS Static Transfer Switch with SafePanel DistributionLayerZero Power Systems, Inc.
 
LayerZero Series 70 ePODs: Type-X Power Distribution Unit with Transformer an...
LayerZero Series 70 ePODs: Type-X Power Distribution Unit with Transformer an...LayerZero Series 70 ePODs: Type-X Power Distribution Unit with Transformer an...
LayerZero Series 70 ePODs: Type-X Power Distribution Unit with Transformer an...LayerZero Power Systems, Inc.
 
LayerZero Series 70: ePanel-HD2 High Density Power Panel
LayerZero Series 70: ePanel-HD2 High Density Power PanelLayerZero Series 70: ePanel-HD2 High Density Power Panel
LayerZero Series 70: ePanel-HD2 High Density Power PanelLayerZero Power Systems, Inc.
 
LayerZero Series 70: eRPP-FS Front/Side Access Remote Power Panel
LayerZero Series 70: eRPP-FS Front/Side Access Remote Power PanelLayerZero Series 70: eRPP-FS Front/Side Access Remote Power Panel
LayerZero Series 70: eRPP-FS Front/Side Access Remote Power PanelLayerZero Power Systems, Inc.
 
LayerZero Series 70: ePanel-2 Wall-Mounted Power Panel
LayerZero Series 70: ePanel-2 Wall-Mounted Power PanelLayerZero Series 70: ePanel-2 Wall-Mounted Power Panel
LayerZero Series 70: ePanel-2 Wall-Mounted Power PanelLayerZero Power Systems, Inc.
 
LayerZero Series 70: ePanel-1 Wall-Mounted Power Panel
LayerZero Series 70: ePanel-1 Wall-Mounted Power PanelLayerZero Series 70: ePanel-1 Wall-Mounted Power Panel
LayerZero Series 70: ePanel-1 Wall-Mounted Power PanelLayerZero Power Systems, Inc.
 
LayerZero Series 70: eRDP Remote Distribution Panel
LayerZero Series 70: eRDP Remote Distribution PanelLayerZero Series 70: eRDP Remote Distribution Panel
LayerZero Series 70: eRDP Remote Distribution PanelLayerZero Power Systems, Inc.
 
DSE335-Data-Sheet (1).pdf
DSE335-Data-Sheet (1).pdfDSE335-Data-Sheet (1).pdf
DSE335-Data-Sheet (1).pdfIrvingGuatemala
 
Catalog Inverter FR-E700 Mitsubishi Electric-Beeteco.com
Catalog Inverter FR-E700 Mitsubishi Electric-Beeteco.comCatalog Inverter FR-E700 Mitsubishi Electric-Beeteco.com
Catalog Inverter FR-E700 Mitsubishi Electric-Beeteco.comBeeteco
 
LayerZero Series 70: eRDP-FS Remote Distribution Panel with Front/Side Access
LayerZero Series 70: eRDP-FS Remote Distribution Panel with Front/Side AccessLayerZero Series 70: eRDP-FS Remote Distribution Panel with Front/Side Access
LayerZero Series 70: eRDP-FS Remote Distribution Panel with Front/Side AccessLayerZero Power Systems, Inc.
 
7SR210 Overcurrent Relay
7SR210 Overcurrent Relay7SR210 Overcurrent Relay
7SR210 Overcurrent Relayashwini reliserv
 
Ats brochure
Ats brochureAts brochure
Ats brochureBimad Sinha
 
Novatek Electro India presentation
Novatek Electro India presentationNovatek Electro India presentation
Novatek Electro India presentationnovatek_india
 
Mitsubishi digital protection relay melpro a series dienhathe.vn
Mitsubishi digital protection relay melpro a series dienhathe.vnMitsubishi digital protection relay melpro a series dienhathe.vn
Mitsubishi digital protection relay melpro a series dienhathe.vnDien Ha The
 
7SR11 Overcurrent Relay
7SR11 Overcurrent Relay7SR11 Overcurrent Relay
7SR11 Overcurrent Relayashwini reliserv
 
7SK81 Motor Protection Relay
7SK81 Motor Protection Relay7SK81 Motor Protection Relay
7SK81 Motor Protection Relayashwini reliserv
 
Iskra Medium Voltage Automation and Protection (Protection relays)
Iskra Medium Voltage Automation and Protection (Protection relays)Iskra Medium Voltage Automation and Protection (Protection relays)
Iskra Medium Voltage Automation and Protection (Protection relays)Minka Grdesic
 
Trio tm-50.0 60.0-bcd.00658_en_rev_e
Trio tm-50.0 60.0-bcd.00658_en_rev_eTrio tm-50.0 60.0-bcd.00658_en_rev_e
Trio tm-50.0 60.0-bcd.00658_en_rev_eDr. Aziz A. Al-Muhtaseb
 

Similar to Reliable Power Distribution and Switching (20)

LayerZero 4-Pole eSTS Static Transfer Switch with SafePanel Distribution
LayerZero 4-Pole eSTS Static Transfer Switch with SafePanel DistributionLayerZero 4-Pole eSTS Static Transfer Switch with SafePanel Distribution
LayerZero 4-Pole eSTS Static Transfer Switch with SafePanel Distribution
 
LayerZero Series 70: eRPP Remote Power Panel
LayerZero Series 70: eRPP Remote Power PanelLayerZero Series 70: eRPP Remote Power Panel
LayerZero Series 70: eRPP Remote Power Panel
 
LayerZero Series 70 ePODs: Type-X Power Distribution Unit with Transformer an...
LayerZero Series 70 ePODs: Type-X Power Distribution Unit with Transformer an...LayerZero Series 70 ePODs: Type-X Power Distribution Unit with Transformer an...
LayerZero Series 70 ePODs: Type-X Power Distribution Unit with Transformer an...
 
LayerZero Series 70: ePanel-HD2 High Density Power Panel
LayerZero Series 70: ePanel-HD2 High Density Power PanelLayerZero Series 70: ePanel-HD2 High Density Power Panel
LayerZero Series 70: ePanel-HD2 High Density Power Panel
 
LayerZero Series 70: eRPP-FS Front/Side Access Remote Power Panel
LayerZero Series 70: eRPP-FS Front/Side Access Remote Power PanelLayerZero Series 70: eRPP-FS Front/Side Access Remote Power Panel
LayerZero Series 70: eRPP-FS Front/Side Access Remote Power Panel
 
LayerZero Series 70: ePanel-2 Wall-Mounted Power Panel
LayerZero Series 70: ePanel-2 Wall-Mounted Power PanelLayerZero Series 70: ePanel-2 Wall-Mounted Power Panel
LayerZero Series 70: ePanel-2 Wall-Mounted Power Panel
 
LayerZero Series 70: ePanel-1 Wall-Mounted Power Panel
LayerZero Series 70: ePanel-1 Wall-Mounted Power PanelLayerZero Series 70: ePanel-1 Wall-Mounted Power Panel
LayerZero Series 70: ePanel-1 Wall-Mounted Power Panel
 
LayerZero Series 70: eRDP Remote Distribution Panel
LayerZero Series 70: eRDP Remote Distribution PanelLayerZero Series 70: eRDP Remote Distribution Panel
LayerZero Series 70: eRDP Remote Distribution Panel
 
Axpert hivert series mv drive
Axpert hivert series mv driveAxpert hivert series mv drive
Axpert hivert series mv drive
 
DSE335-Data-Sheet (1).pdf
DSE335-Data-Sheet (1).pdfDSE335-Data-Sheet (1).pdf
DSE335-Data-Sheet (1).pdf
 
Catalog Inverter FR-E700 Mitsubishi Electric-Beeteco.com
Catalog Inverter FR-E700 Mitsubishi Electric-Beeteco.comCatalog Inverter FR-E700 Mitsubishi Electric-Beeteco.com
Catalog Inverter FR-E700 Mitsubishi Electric-Beeteco.com
 
LayerZero Series 70: eRDP-FS Remote Distribution Panel with Front/Side Access
LayerZero Series 70: eRDP-FS Remote Distribution Panel with Front/Side AccessLayerZero Series 70: eRDP-FS Remote Distribution Panel with Front/Side Access
LayerZero Series 70: eRDP-FS Remote Distribution Panel with Front/Side Access
 
7SR210 Overcurrent Relay
7SR210 Overcurrent Relay7SR210 Overcurrent Relay
7SR210 Overcurrent Relay
 
Ats brochure
Ats brochureAts brochure
Ats brochure
 
Novatek Electro India presentation
Novatek Electro India presentationNovatek Electro India presentation
Novatek Electro India presentation
 
Mitsubishi digital protection relay melpro a series dienhathe.vn
Mitsubishi digital protection relay melpro a series dienhathe.vnMitsubishi digital protection relay melpro a series dienhathe.vn
Mitsubishi digital protection relay melpro a series dienhathe.vn
 
7SR11 Overcurrent Relay
7SR11 Overcurrent Relay7SR11 Overcurrent Relay
7SR11 Overcurrent Relay
 
7SK81 Motor Protection Relay
7SK81 Motor Protection Relay7SK81 Motor Protection Relay
7SK81 Motor Protection Relay
 
Iskra Medium Voltage Automation and Protection (Protection relays)
Iskra Medium Voltage Automation and Protection (Protection relays)Iskra Medium Voltage Automation and Protection (Protection relays)
Iskra Medium Voltage Automation and Protection (Protection relays)
 
Trio tm-50.0 60.0-bcd.00658_en_rev_e
Trio tm-50.0 60.0-bcd.00658_en_rev_eTrio tm-50.0 60.0-bcd.00658_en_rev_e
Trio tm-50.0 60.0-bcd.00658_en_rev_e
 

Recently uploaded

Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitecturePixlogix Infotech
 
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | DelhiFULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhisoniya singh
 
Install Stable Diffusion in windows machine
Install Stable Diffusion in windows machineInstall Stable Diffusion in windows machine
Install Stable Diffusion in windows machinePadma Pradeep
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountPuma Security, LLC
 
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks..."LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...Fwdays
 
Key Features Of Token Development (1).pptx
Key  Features Of Token  Development (1).pptxKey  Features Of Token  Development (1).pptx
Key Features Of Token Development (1).pptxLBM Solutions
 
Pigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food ManufacturingPigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food ManufacturingPigging Solutions
 
Scanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsScanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsRizwan Syed
 
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024BookNet Canada
 
CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):comworks
 
Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Allon Mureinik
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024Scott Keck-Warren
 
APIForce Zurich 5 April Automation LPDG
APIForce Zurich 5 April  Automation LPDGAPIForce Zurich 5 April  Automation LPDG
APIForce Zurich 5 April Automation LPDGMarianaLemus7
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Patryk Bandurski
 
Artificial intelligence in the post-deep learning era
Artificial intelligence in the post-deep learning eraArtificial intelligence in the post-deep learning era
Artificial intelligence in the post-deep learning eraDeakin University
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking MenDelhi Call girls
 
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024BookNet Canada
 
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptxMaking_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptxnull - The Open Security Community
 

Recently uploaded (20)

Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC Architecture
 
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | DelhiFULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
 
Install Stable Diffusion in windows machine
Install Stable Diffusion in windows machineInstall Stable Diffusion in windows machine
Install Stable Diffusion in windows machine
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path Mount
 
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks..."LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
 
Key Features Of Token Development (1).pptx
Key  Features Of Token  Development (1).pptxKey  Features Of Token  Development (1).pptx
Key Features Of Token Development (1).pptx
 
Pigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food ManufacturingPigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food Manufacturing
 
The transition to renewables in India.pdf
The transition to renewables in India.pdfThe transition to renewables in India.pdf
The transition to renewables in India.pdf
 
Scanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsScanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL Certs
 
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
 
E-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptx
E-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptxE-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptx
E-Vehicle_Hacking_by_Parul Sharma_null_owasp.pptx
 
CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):
 
Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024
 
APIForce Zurich 5 April Automation LPDG
APIForce Zurich 5 April  Automation LPDGAPIForce Zurich 5 April  Automation LPDG
APIForce Zurich 5 April Automation LPDG
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
 
Artificial intelligence in the post-deep learning era
Artificial intelligence in the post-deep learning eraArtificial intelligence in the post-deep learning era
Artificial intelligence in the post-deep learning era
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
 
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
 
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptxMaking_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
 

Reliable Power Distribution and Switching

  • 1. Series 70 ePODs: Type-P Static Transfer Switch → Transformer → Distribution The Foundation Layer Product Brochure
  • 2. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P ePODs: Type-P STS/PDU Combination Increases Reliability and Operator Safety LayerZero Power Systems designed the Series 70 ePODs: Type-P to provide switching between multiple sources and finger- safe power distribution in an easy-to-deploy package. The ePODs: Type-P provides switching between two independent power sources on the primary side of the transformer, while providing power distribution capabilities, featuring a solid-state transfer switch on the primary side of the transformer. The Series 70 ePODs: Type-P provides the ability to transfer power between two or three sources in quarter of an electrical cycle, while delivering that power to up to twelve sub-feed circuit breakers or to branch circuit panel boards. The Finger-Safe SafePanel is IP-20, inspired by the reccomendations of NFPA-70E. In addition, ePODs: Type-P includes Zen DPQM™, LayerZero’s Static Transfer Switch power quality monitoring system. The LayerZero ePODs: Type-P PDU Increases Operator Safety Up to 12 CB positions 1200A SafePanel 1 Source 1 Input Source 2 Input 480V, 3-phase, 3-wire or 600V, 3-phase, 3-wire 202BC102BC 201BC101BC CNCN NO NO CB302CB301 NC NC Up to 12 CB positions 1200A SafePanel 2 NCCB701 NO CB702 NCCB601 NO CB602 T620 TVSS620 SA620 120/208V, 3-phase, 4-wire or 240/415V, 3-phase, 4-wire TVSS601 Series 70 ePODs: Type-P One Line Diagram 2 © Copyright 2016 LayerZero Power Systems, Inc.
  • 3. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P ;; Optional Triple Modular Redundancy: TMR Contains Fully-Independent Control Paths With No Single Point-Of-Failure ;; Safe Bypass Procedure: Mechanical Bypass Interlock Eliminates Human Error When Performing Bypass Procedures ;; Voice Guided Bypass: Step-By-Step Instructions With Audio and Video Guidance To Assist Operators Through Bypass ;; Convection Cooling: Natural Convection-Cooled Heat Dissipation System is Maintenance-Free ;; Epoxy Coated Buswork: Maximizes Reliability By Eliminating The Possibility of Bus-To-Bus Faults ;; Silver Plated Terminals: Silver Has Excellent Conductivity To Provide Superior Electrical Performance and Reliability ;; Maintenance-Free Joints: Brazed Joints Are Permanent And Maintenance-Free, Maximizing Product Life ;; Machined Hardware: Machined Cap Screws and Engineered Disc Springs Maintain Constant Torque Throughout Product Life ;; Screw Thread Inserts: Prevents Screws From Loosening Under Vibration For Long-Term Reliability ;; Optical Fiber Based Controls: Eliminates Noise and Interference While Isolating Components from High Voltage ;; Serialized Critical Board Tracking: Critical Boards Are Serialized And Cataloged in an Active Database For Traceability ;; Transformer Vibration Isolation: Vibro-Elastic Pads to Absorb Vibrations from the Transformer Reliability LayerZero’s ePODs: Type-P Is Equipped Fully-Loaded Safety ;; InSight™ IR Portholes: Bolted Connections & Critical Boards Can Be IR Scanned With the Dead-Front Doors Closed ;; Sectionalized Components: Isolated Sections That Can Be Safely De-Energized For Performing Maintenance ;; Polycarbonate Windows: Allows Critical Board LEDs To Be Viewed With The Dead-Front Door Closed ;; Front-Only Access: Installation and Maintenance Can Be Safely Performed Without Side or Rear Access ;; Dead Front Hinged Doors: Barrier To Provide A Safe Working Area With No Exposed Live Parts ;; SafePanel™ Distribution: NFPA-70E Inspired Finger-Safe Panel Board With No Exposed Live Parts Connectivity ;; Ethernet Connectivity: Secure VPN Router Connects To Network For Advanced Remote Monitoring Capabilities ;; Modbus/TCP: Open Connectivity to Existing Monitoring Systems Without Proprietary Limitations ;; NTP Time Clock Synchronization: Facilitates Timeline-Based Logging For Post-Event Reconstruction ;; SNMP Connectivity: Permits Remote Management Via Simple Network Management Protocol ;; Real-Time Waveform Capture: Automatically Captures A Picture Of The Power Three-Cycles Before and After Every Event ;; Local Touch-Screen Interface: Password-Protected Color Touch-Screen GUI For Local STS Setup/Operation/Administration ;; Black-Box Forensics: eSTS Captures and Records All Events To Provide Vital Information In Root-Cause Analysis ;; Waveforms Automatically Emailed: Capability to Send Waveform Captures To Designated Individuals For Every Transfer 3 © Copyright 2016 LayerZero Power Systems, Inc.
  • 4. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P eSTS: Size: 250 A, 400 A, 600 A, 800 A Voltage: 480 V, 3-W; 600 V, 3-W Redundancy: • Triple Modular Redundant (TMR) • Single Module Redundant (SMR) • Output Switch: Redundant, • Non-redundant Transformer section: Size: 150kVA; 225kVA; 300kVA; 400kVA; 500kVA Type: Normal Efficiency, TP-1 high efficiency Inrush: Low-inrush Non-linear thermal rating: K-9, K-13, K-20 Main Circuit Breaker Section: MCB optional Mounting: Fixed, Plug-In Type: • Molded Case Switch 65kA, 100kA • Electronic Trip 65kAIC, 100kAIC Accessories: • CB Shunt-trip 120VAC, 24VDC CB Position Indication: • Open, Tripped, Closed Distribution Section: Sub-feed distribution • 1200 A SafePanel Up to six (6) 42-circuit, 225A or 400A panel boards Equipment Layout ePODs: Type-P Distribution Supports Top or Bottom Exit, Feeding Directly to Power Panels. 4 © Copyright 2016 LayerZero Power Systems, Inc.
  • 5. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P 1 3 4 5 2 6 7 8 9 10 11 12 13 14 1615 16 17 18 19 20 1. Alarmed Doors 2. Hinged Dead Front Doors 3. Silver Plated Terminals 4. 15” Color Touch Screen GUI 5. Printed Bypass Instructions 6. Polycarbonate Window 7. InSight™ IR Portholes 8. Convection Cooled Heat Sinks 9. Staggered Gate Drive Arrangement 10. Epoxy Coated Buswork 11. Circuit Breakers 12. Redundant Power Supplies 13. Louvered Convection Cooled Intake 14. Transformer 15. Transformer Circuit Breaker 16. SafePanel™ 17. SafePanel™ Shrouds 18. Universal Dead Front Door 19. Cable Organization Clips 20. Up to 12 Subfeed Circuit Breakers Equipment Construction Detail 5 © Copyright 2016 LayerZero Power Systems, Inc.
  • 6. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P Distribution Configuration Options Highly Configurable Distribution The Series 70 ePODs: Type-P is available in a wide variety of configurations. ePODs: Type-P is equipped standard with a Static Transfer Switch, Transformer, and Distribution in an easy- to-deploy package. Distribution options include up to four 42-circuit branch circuit breakers (168 total), and subfeeds. Optional configurations include: • Front-Only Distribution • Front + 1-Side Distribution • Front, Left, and Right 6 © Copyright 2016 LayerZero Power Systems, Inc.
  • 7. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P LayerZero ePODs: Type-P Reliability Overview The LayerZero ePODs: Type-P Provides Many Dimensions of Reliability: • Control System Reliability • SMR (Single Module Redundancy, Standard) • TMR (Triple Modular Redundancy, Optional) • Control Power Supply Reliability • Signal Reliability • Operator Procedural Reliability Gate Drive 1 Source 1 A Gate Drive 2 Source 1 B Gate Drive 3 Source 1 C Gate Drive 4 Source 2 A Gate Drive 5 Source 2 B Gate Drive 6 Source 2 C Source 1 Control Source 2 Control WAN Port Fiber Optics SCB 1 Single Module Redundancy (SMR) Reliability (Standard) Single Module Redundancy is a cost-effective topology that provides redundant power paths to mission-critical equipment. In SMR systems, sources each have built-in triple redundancy of processors. In addition, every phase is controlled with a separate gate drive board. LayerZero Single Modular Redundant topology is unique that it the system is fail-safe, maintaining full switching functionality even if a critical board were to fail. Reliability Overview 7 © Copyright 2016 LayerZero Power Systems, Inc.
  • 8. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P Reliability Features: Triple Modular Redundancy (TMR) *Optional eSTS TMR Triple Redundant Power Supply Architecture Has All Redundancy Features of SMR Architecture, Plus: Each STS has three independent sets of analog and digital data acquisition and control systems. There is no direct communication between the three systems. The three systems do not even share a common system clock. • Each control system acquires voltage and current data independently • Each control system determines whether a source is good/bad independently • Upon loss of a source, each control system makes decisions to transfer independently Each SCR pair is driven by three separate actuators (gate drives) Even if an entire control path or its subcomponent were to fail; and then if the active power source were to fail, the STS is designed to meet its emergency transfer specifications. It is able to complete its mission of transferring to the alternate source. Gate Drive 1 Source 1 A Gate Drive 2 Source 1 B Gate Drive 3 Source 1 C Gate Drive 4 Source 2 A Gate Drive 5 Source 2 B Gate Drive 6 Source 2 C Source 1 Control Source 2 Control Source 1 Control Source 2 Control Source 1 Control Source 2 Control WAN Port Fiber Optics SCB 1 SCB 2 (TMR) SCB 3 (TMR) 8 © Copyright 2016 LayerZero Power Systems, Inc.
  • 9. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P eSTS SMR Triple Redundant Power Supply Architecture Divided into four (4) logical failure groups: • System controls • Source 1 gate drives • Source 2 gate drives • Peripherals. The three (3) available source of power from which to supply control power to each failure group are: • Source 1 • Source 2 • STS Output. LayerZero’s STS design incorporates twelve (12) power supplies (3 power sources x 4 failure groups.) The resultant control power topology utilizes all possible power paths to the four logical STS failure groups; and is the most comprehensive and redundant power supply system in existence. Reliability Features: Single Module Redundant (SMR) Redundancy Peripherals PS 1 S1 A-B Source 1 A B C Source 2 A B C PS 4 S1 B-C PS 7 S1 A-C PS 10 S1 A-B PS 3 S2 B-C PS 6 S2 A-C PS 9 S2 A-B PS 12 S2 B-C System Controls Gate Drives, Source 1 Gate Drives, Source 2 GD 1 GD 3 GD 5 SCB 1 SCB 2 TMR Only SCB 3 TMR Only GD 2 GD 4 GD 6 PS 5 Out A-B System Controls PS 8 Out B-C Gate Drives S1 PS 11 Out A-C Gate Drives S2 PS 2 Out A-C Peripherals Output Bus A B C eSTS SMR Triple Redundant Processors • Separate/independent processors for Source 1, Source 2 and Output power quality analysis • If Source 1 processor malfunctions then system is able to be commanded to transfer to Source 2; & vice versa. • If main control system fails then STS continues to conduct power to the load from the existing source of power. (However STS is unable to transfer to the other source) • Each phase of each source is controlled with a separate gate drive circuit board. S1 S2 Output Gate Drive 1 Gate Drive 2 Gate Drive 3 Gate Drive 4 Gate Drive 5 Gate Drive 6 A B C A B C Source 1 Transfer Control Source 2 Transfer Control 9 © Copyright 2016 LayerZero Power Systems, Inc.
  • 10. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P Fiber Optic Controls Increase System Reliability Fiber optic based controls eliminate noise and interference, while isolating components from high voltage. Optical fiber allows service to be reliably connected, while protecting the equipment. In LayerZero’s ePODs: Type-P design, the gate drives (at Power Circuit Voltage) recieve control signsals via optical fibers. Reliability Features 10 © Copyright 2016 LayerZero Power Systems, Inc.
  • 11. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P No Fans, Dust Filters, or Fan Fuses Fans and fan sensors are one of the most common components to fail. For maximum uptime, Type-P systems do not contain any fans, dust filters to change, or fan fuses to replace. The Series 70 ePODs: Type-P utilizes a natural convection-cooled heat dissipation system. The heat sink arrangement is staggered between sources and phases to minimize the creation of extreme thermal gradients between heat sink columns when conducting on one source or the other. Reliability Features Epoxy Coated Buswork Our usage of epoxy coated buswork helps ensure safety, and makes the system inherently more reliable by eliminating the possibility of bus-to- bus faults. Silver Plating LayerZero utilizes silver plating on all bus joints and terminals to be able to provide the highest performance. Silver has high conductivity and low resistance - which makes for a great contact. 11 © Copyright 2016 LayerZero Power Systems, Inc.
  • 12. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P Mechanical Bypass Interlock In order to minimize the possibility of operator error during equipment bypass operations, LayerZero provides: 1. Interlocked breakers 2. Mechanisms to ensure that a source cannot be bypassed without the STS on the correct source. 3. Safeguards to make certain that sources cannot be connected to each other inadvertently. 4. A voice-prompted bypass procedure that guides the operator through the sequence. 5. A step-wise pictorial & video presentation is provided on the touch-screen display during bypass. Reliability Features Voice Guided Bypass Operator error during maintenance bypass has been known to be a reliability hazard. To help prevent operators from completing the bypass procedure out-of-sequence, our product features a voice prompted bypass procedure. This instructs the operator in a step-by-step course of action of the process, with only one operation per screen. Visual and audio cues provide clear instructions on the bypassing sequence, reducing the probability of operator error. 12 © Copyright 2016 LayerZero Power Systems, Inc.
  • 13. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P Vibration Isolation Damper Mounts Transformers in the Series 70: ePODs Type-P Power Distribution Unit are equipped with vibration isolation damper mounts, helping to reduce the amount of vibration and noise that originates from transformers, ultimately leading to a higher reliability of electrical and mechanical connections over the life of the product. Sectionalization Maximizes Operator Safety Operators are well-protected from exposed connections. Normal operator sections (breakers/switches) are physically separated from the power electronics and control electronics sections, so that maintenance on a section can be safely performed. If maintenance is required on a particular section, power can be bypassed to another section to allow for safe repairs to be made. Ease of Maintenance 13 © Copyright 2016 LayerZero Power Systems, Inc.
  • 14. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P InSight™ IR Portholes Permit Scanning of Bolted Connections with Dead-Front Doors Closed Strategically positioned IR-scan portholes to enable safe thermal scanning of all bolted connections with the deadfront closed, without exposing the operator to power circuit voltage. Thermal scans can be done from the front – without ever having to open the dead-front door. The IR window swivels upward and unlocks with key-hole access to reveal a mesh, allowing the operator to point- and-shoot thermal cameras to obtain readings. Elevated Transformer Mounting: 1. Eliminates parasitic plenum airflow 2. 4” rear clearance required Ease of Maintenance 14 © Copyright 2016 LayerZero Power Systems, Inc.
  • 15. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P View Status LEDs and Distribution CB Positions With Dead-Front Doors Closed Our Series 70 product line was inspired by NFPA-70E, to help critical facilities drastically reduce the risks of their energy distribution systems. Operators can view the status of diagnostic LEDs without exposure to the energized power electronics section. In addition, SafePanel circuit breaker positions can be viewed with the dead-front door closed. Modbus/TCP http:// through a standard web browser Network Time Protocol (NTP) Compliant Simple Network Management Protocol (SNMP) Waveforms Automatically Emailed Series 70 ePODs: Type-P Standard Ethernet Dry Contacts • Meters • Alarms • Meters • Alarms • Waveforms • History/Event Log • Diagnostics • Summary Alarm • On Source 1 • On Source 2 • Source 1 Available • Source 2 Available For Clock Synchronization Ease of Maintenance/Connectivity Options 15 © Copyright 2016 LayerZero Power Systems, Inc.
  • 16. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P The LayerZero Finger-Safe SafePanel™ The Series 70 ePODs: Type-P features an IP-20, finger-safe panel board, meaning that the opening will not allow ingress of ½” (12.5mm) diameter probe, for maximum operator safety. An arc can form as two live conductors are separated – such as the removal of a circuit breaker from a panel board. The SafePanel design ensures that a potential arc would be contained in the connection well so that even if a branch breaker were to be removed, the arc would be contained in the connection well. Insulated with the components deeply isolated, removal of the breaker is safe and easy. The Protective Cover Is Removed The Breaker Is Inserted Into The Opening The Breaker Snaps Into The DIN Rail The Breaker Is Secured With An Isolated, Non Conducting Screw Safety Features 16 © Copyright 2016 LayerZero Power Systems, Inc.
  • 17. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P Circuit Breaker Shrouds LayerZero Series 70 ePODs: Type-P configured with 42-circuit panel boards provide optional circuit breaker shrouds, designed to eliminate exposure to live parts. No Exposed Live Parts LayerZero’s patent-pending Circuit Breaker Shrouds cover exposed wiring, maximizing operator safety. Wiring Without Shrouds Leaves Wiring Exposed Circuit Breaker Shrouds Maximize Operator Safety Safety Features 17 © Copyright 2016 LayerZero Power Systems, Inc.
  • 18. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P The Breaker Is Inserted Into The SafePanel The Handle Is Unlocked Screws Help Secure The Breaker For Maximum Safety, The SafePanel Has Recessed Bus Work and Finger Safe Lattice. Type-P 1200 A Circuit Breaker Installation Process The LayerZero SafePanel™ The Series 70 ePODs: Type-P features an IP-20, finger-safe panel board, meaning that the opening will not allow ingress of ½” (12.5mm) diameter probe, for maximum operator safety. An arc can form as two live conductors are separated – such as the removal of a circuit breaker from a panel board. The SafePanel design ensures that a potential arc would be contained in the connection well so that even if a branch breaker were to be removed, the arc would be contained in the connection well. Insulated with the components deeply isolated, removal of the breaker is safe and easy. Safety Features 18 © Copyright 2016 LayerZero Power Systems, Inc.
  • 19. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P The Series 70 ePODs: Type-P is equipped with Zen SSQM (Static Switch Quality Monitoring), an all encompassing monitoring system with local and remote communications options. From basic monitoring & alarm reporting, to advanced power quality monitoring functionality, Zen SSQM provides a wide-range of options to help you be aware, be vigilant, be proactive in your quest to create a safe, stable and reliable operation. Zen SSQM Provides Answers Zen SSQM provides timestamped pictures of waveforms before and after events, providing information that enables facilities to go back in time to methodically identify and correct the root causes of events. Zen actively captures power quality information at the STS, PDU, and RPP - permitting thorough post-event analysis. Product Name: Series 70 ePODs: Type-P Unit Name: 500 + 1000 turn CTs Serial #: 10028-34 Capture Reason: SQ Xfer 0-1 Captured By: scb122 Capture Time: 01-04-2016 6:53:08 PM Microticks: 1449941 Phase A Phase B Phase C Phase N Phase G Source 1 Volts L-L Milliseconds V o l t s 0 -200 200 -400 400 -600 600 -800 800 -1000 1000 Source 2 Volts L-L Milliseconds V o l t s 0 -200 200 -400 400 -600 600 -800 800 -1000 1000 Load Volts L-L V o 200 400 600 800 1000 Trigger Event 3 Electrical Cycles 3 Electrical Cycles Waveform Capture of Current in a Source TransferPhase A Phase B Phase C Power Quality Monitoring 19 © Copyright 2016 LayerZero Power Systems, Inc.
  • 20. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P A CT101 ACT102 ACT301 ACT620 CT1 A CT2 A CT4 A CT3 A V V V VV2 PQ PQ BM BM2BM1BM CB101 CB102 CB601 CB602CB101 CB301 CB102 CB302 CB201 CB202 T620 SSW1 SSW2SSW1 SSW1 SSW2 SSW2 SSW2 SSW2 Subfeeds A V PQ Current Metering Point Voltage Metering Point Power Quality Metering Point BM Branch Current Monitoring Power Quality Monitoring 20 © Copyright 2016 LayerZero Power Systems, Inc.
  • 21. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P Zen SSQM Parameters Mains Subfeeds or Branch Circuits Voltage Inputs and Output Voltage Frequency (Hertz) Phase Rotation Current Inputs Current (Amps) Current Fraction of Rating (Percent) Current Imbalance (Percent) Real Power (kilowatts) Apparent Power (kilovolt-amperes) Reactive Power (kilovolt-amperes reactive) Power Factor K Factor Crest Factor Alarms Summary Alarm Voltage (High, Low) Overload Thermostat (High, Low) THD Over Limit Frequency (Over, Under) I A/B/C K-Factor Over Limit Average K-Factor Over Limit Incorrect Phase Rotation Voltage Failure I G1/G2 Over Ground Fault Limit I G1/G2 Over Ground Overcurrent Limit TVSS 1/2/3/4 Failure Technical Specifications All product specifications are subject to change without notice. 21 © Copyright 2016 LayerZero Power Systems, Inc.
  • 22. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P ePODs: Type-P Models with Withstand Ratings 208 V @ 240 V 480 V 575 V 600 V 225 A 65 kAIC; 50 kAIC 35kAIC; 25kAIC 10kAIC 250 A 200 kAIC; 150 kAIC; 100 kAIC; 65 kAIC 150kAIC; 100kAIC; 65kAIC; 35kAIC; 25kAIC; 100kAIC; 65kAIC; 35kAIC; 25kAIC; 18kAIC400 A 200 kAIC; 150 kAIC; 100 kAIC; 65 kAIC 600 A 200 kAIC; 100 kAIC; 65 kAIC800 A 100kAIC; 65kAIC; 50kAIC; 35kAIC 42kAIC; 35kAIC; 25kAIC; 20kAIC Mechanical Characteristics 75kVA 150kVA 225kVA 300kVA 400kVA 500kVA 600kVA Dimensions (side facing distribution) : 96”W x 88”H x 36”D (2438 mm x 2235 mm x 914 mm) 108”W x 88”H x 36”D (2743 mm x 2235 mm x 914 mm) 125”W x 88” H x 36” D (3175 mm x 2235 mm x 914 mm) Dimensions (front facing distribution) : 120”W x 88”H x 36”D (3048 mm x 2235 mm x 914 mm) 132”W x 88”H x 36”D (3353 mm x 2235 mm x 914 mm) 145”W x 88” H x 36” D (3683 mm x 2235 mm x 914 mm) Weight: 2000 - 3000 lbs (907 kg - 1361 kg) Varies on Configuration, Please Contact LayerZero Engineering Heat Dissipation: Varies on Transformer Efficiency, Please Contact LayerZero Engineering. Frame Construction Welded Frame Electrical Connections Flexible Laminated Bus, Silver-Plated Solid Busbar Color Textured Powder Coat White (RAL 7035), Blue (RAL 5017), Black, Custom Seismic Floor Anchors Optional Seismic Floor Stand Optional Sectionalization Engineered Composite Insulation, Dead Front Doors Electrical Characteristics Static Transfer Switch Number of Inputs 2, 3 eSTS Number of Output CBs 1, 2 Frequency 50 Hz, 60 Hz Poles 3-pole, 4-pole Phases 3 Phase, 3 Wire, 4 Wire + Ground Neutral Rating 100%, 150%, 200% eSTS Transfer Time Nominal 1/4- cycle for in-phase sources eSTS Redundancy Single Module Redundancy, Triple Modular Redundancy (Optional) eSTS Circuit Breaker Type Molded Case Switch (Standard), Electronic Trip (Optional) Circuit Breaker Mounting Type Plug-In up through 600 A; Draw-out 800 A, 1200 A eSTS TVSS Standard EPO Optional Subfeed Distribution Distribution SafePanel™ Distribution Technical Specifications All product specifications are subject to change without notice. 22 © Copyright 2016 LayerZero Power Systems, Inc.
  • 23. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P Power Quality Monitoring Power Quality Monitoring Technology Zen SSQM™ (Static Switch Quality Monitoring) Waveform Capture Local Display, Remote Display via Web Browser, Waveforms Automatically Emailed Voltmeter Input sources and Output, for each phase Ammeter Input sources and Output, for each phase Frequency Meter Both Sources Real-Time Synchroscope Phase Angle Meter Between Sources Metering Apparent Power, Real Power, Power Factor, Output Total Harmonic Distortion Time Stamped Transfer Count From First Day Use, From Last Reset CB Status Indicator Open/Closed/Tripped Circuit Breaker Source Indicator Preferred Source Phase Indicator When Any Two Sources Are Within Window Power Path Indicator On Live Mimic Operational Characteristics Transfer Modes Automatic; Manual (via Preferred Source Selection) Inrush Mitigation Technology Patented Dynamic Phase Compensation Algorithm (U.S. Patent 7,589,438 B2) Cooling Convection Cooling Cable Access Top/Bottom Service Access Front Only Bypass Interlock Mechanism Mechanical Noise & Interference Isolation Optical Fiber in Critical Control Paths IR Scan Port Type InSight™ IR Portholes SCR Type Puck Display Type 15” Color Touch Screen Display Resolution 1024x768 Bypass Assistance Voice-Guided Bypass Audio Bezel-Mounted Stereo Speakers Languages English, French Mimic Panel Digital Setpoints Control Digital Power Supplies Redundant (4 Failure Groups. Triple Redundant Supplies. 12 Power Supplies Provided.) Standards Conformance: Static Transfer Switch UL ETL Listed to UL 1008S CSA ETL Listed to C22.22 No 107. Standards Conformance: SafePanel Distribution UL ETL Listed to UL 60950 CSA C22.2 No 29-M1989 Contact LayerZero for custom sizes and designs. Notes: 1) Depth dimensions are valid for Sub-feed distribution. For panel board distribution, depth is 48". 2) Add 12" to width and Left side access for (5) or (6) 42-circuit panel boards 3) Rear access not required for installation; operation; and maintenance Technical Specifications All product specifications are subject to change without notice. 23 © Copyright 2016 LayerZero Power Systems, Inc.
  • 24. Static Transfer Switch/Power Distribution UnitSeries 70 ePODs: Type-P Connectivity Meters Local Display, Ethernet, Modbus/TCP, http via Web Browser (Non-Proprietary) Alarms Local Display, Ethernet, Modbus/TCP, http via Web Browser (Non-Proprietary) Summary Alarm Dry Contacts Waveforms Local Display, Ethernet, http via Web Browser (Non-Proprietary) History/Event Log Local Display, Ethernet, http via Web Browser (Non-Proprietary) Diagnostics Local Display, Ethernet, http via Web Browser (Non-Proprietary) Time Synchronization Network Time Protocol (NTP) Number of Output Circuit Breakers Number of Available SafePanel™ Slots 36 CB Rating Number of Slots Required 100 AF 2 250 AF 3 400 AF 3 400 AF 100% 6 800 AF 6 36 Total Available Slots 1 Slot 2 Slots 3 Slots 6 Slots Universal Dead FrontSafePanel™ Panel Board Interchangeable Plates Fit All CB Sizes Blank Plates All product specifications are subject to change without notice. Technical Specifications 24 © Copyright 2016 LayerZero Power Systems, Inc.
  • 25. LayerZero Power Systems, Inc. 1500 Danner Drive Aurora, OH 44202 U.S.A. © 2016 LayerZero Power Systems, Inc. LayerZero Power Systems, LayerZero.com and the LayerZero logo are registered trademark of LayerZero. All product specifications are subject to change without notice. Learn more at www.LayerZero.com Rev. 7/16 #16