Series 70 ePanel-2
Wall-Mounted Remote Power Panel
The Foundation Layer
Product Brochure
ePanel: Save Space, Increase Safety,
And Maximize Reliability
ePanel Uses A Wall-Mounted Design To Maximize The Effectiveness Of Critical Floor Space
Web-enabled Series 70: ePanel-2 Wall-Mounted Distribution Panels save space. ePanel is highly configurable to meet a variety of
business goals, and can be installed at the end of server rows or on the walls. The ePanel utilizes the IP-20 finger-safe SafePanel™,
requires Category-0 PPE, provides selective trip coordination to 35 kAIC, enables Bluetooth connectivity, contains waveform
capture on every breaker, with Modbus/TCP, SNMP, HTTP web browsing protocols supported.
Wall-Mounted Power PanelSeries 70 ePanel-2
2 © Copyright 2016 LayerZero Power Systems, Inc.
LayerZero’s ePanel-2 Product Features
;; Silver Plated Input Terminals: Silver Has Excellent Conductivity To Provide Superior Electrical Performance and Reliability
;; Machined Hardware: Machined Cap Screws and Engineered Disc Springs Maintain Constant Torque Throughout Product Life
;; Convection Cooling: Natural Convection-Cooled Heat Dissipation System is Maintenance-Free
;; Serialized Critical Board Tracking: Critical Boards Are Serialized And Cataloged in an Active Database For Traceability
;; Selective Trip Coordination: Main Breaker Will Not Trip In The Event of a Downstream Fault.
Reliability
Safety
;; InSight™ IR Portholes: Bolted Connections Can Be IR Scanned With the Dead-Front Doors Closed
;; Sectionalized Components: Separations Between Each Section To Maintain Maximum Operator Safety
;; Polycarbonate Windows: Allows Circuit Breaker Positions Viewed With The Dead-Front Door Closed
;; Dead Front Hinged Doors: Barrier To Provide A Safe Working Area With No Exposed Live Parts
;; Guided Wireways: Helps Keep Wires Organized
Connectivity
;; Ethernet Connectivity: Secure VPN Router Connects To Network For Advanced Remote Monitoring Capabilities
;; Modbus/TCP: Open Connectivity to Existing Monitoring Systems Without Proprietary Limitations
;; NTP Time Clock Synchronization: Facilitates Timeline-Based Logging For Post-Event Reconstruction
;; SNMP Connectivity: Permits Remote Management Via Simple Network Management Protocol
;; Bluetooth Connectivity: Wirelessly Set Up Panels At The Point-Of-Impact
;; Real-Time Waveform Capture: Automatically Captures A Picture Of The Power Six-Cycles Before and After Every Event
;; Optional Local Touch-Screen Interface: Password-Protected Color Touch-Screen GUI For Local ePODs Setup/Operation
;; Black-Box Forensics: ePanel-2 Captures and Records Events To Provide Vital Information In Root-Cause Analysis
Wall-Mounted Power PanelSeries 70 ePanel-2
3 © Copyright 2016 LayerZero Power Systems, Inc.
Polycarbonate Window
to view Circuit Breaker
Positions
InSight™ IR Portholes
to Thermal Scan Bolted
Connections
Compression
Connections at Input
Feeder
Flexible Laminated Bus
for Higher Reliability
Two 42-Circuit
SafePanel™ Panel
Boards
Guided Wireways
for Organized
Cabling
Circuit Breaker
Designation Cards
ePanel-2 input Is Supplied
from STS Output
Wall-Mounted Power PanelSeries 70 ePanel-2
4 © Copyright 2016 LayerZero Power Systems, Inc.
Equipment Layout
Serialized circuit boards
We serialize and track all critical circuit boards and memory cards
through our eBOSS portal, which allows customers to reference
which components their machines are made from, who tested the
components, as well as the ability to view notes generated from
testing.
Serialized components offer the ability to drill-down on prospective
component failure utilizing predictive modeling techniques, so if part
fails, the instance can be cross-referenced with similar parts. This
preventative maintenance helps ensure maximum uptime.
Sectionalized Components Help Maximize Operator
Safety
Operators are well-protected from exposed connections. There
is a physical separation between the main circuit breaker(s) and
branch circuit breakers. All connections are optically isolated
to minimize risk. Polycarbonate windows are utilized to permit
visibility and maximize operator safety.
Energized parts are all insulated, covered, recessed, &/or
internally mounted for safer operation of the unit. In addition,
sections that isolate machine components are insulated.
Wall-Mounted Power PanelSeries 70 ePanel-2
5 © Copyright 2016 LayerZero Power Systems, Inc.
Reliability Features
Selective Trip Coordination
LayerZero Series 70 ePanel-2 Wall-Mounted Power Panels are selective
trip coordinated.
Selective Trip Coordination ensures that the main breaker will remain
unaffected by the branch circuit breakers in the event of a downstream
fault.
The Fault Current Opens the Solenoid
Magnet, Causing The Contacts To Part
Unequal Pressure on Each Side of The
Arc Causes the Plasma Wave To Rotate
Away From The Contacts
The Plasma Wave is Driven into 12
Evenly Spaced Dividers
The Plasma is Rapidly Cooled Transient Voltage Attempts To Re-
Strike The Arc, But The Plasma Is Again
Pushed Into The Dividers
When Sufficiently Cool, Charged
Particles Recombine And The Fault
Current Is Stopped Quickly & Safely
Wall-Mounted Power PanelSeries 70 ePanel-2
6 © Copyright 2016 LayerZero Power Systems, Inc.
Reliability Features
77
Scan Bolted Connections with Dead-Front Doors Closed
The left inner dead-front doors contain strategically positioned
IR-scan portholes to enable safe thermal scanning of all bolted
connections with the deadfront closed, without exposing the
operator to power circuit voltage.
The IR window swivels upward and unlocks with key-hole access
to reveal a mesh, allowing the operator to point-and-shoot
thermal cameras to obtain accurate readings. LayerZero provides
documentation for proper thermal scanning procedures.
Polycarbonate Windows
The Series 70: ePanel-2 is equipped with polycarbonate windows
located on the outer doors. Circuit breaker positions can be viewed
with the dead-front doors closed.
In addition, a hinged polycarbonate window on the input terminals
increases safety by eliminating exposure to live bus.
Wall-Mounted Power PanelSeries 70 ePanel-2
7 © Copyright 2016 LayerZero Power Systems, Inc.
Ease of Maintenance/Safety Features
Circuit Breaker Shrouds
LayerZero Series 70 ePanel-2 Power Panel provides optional
circuit breaker shrouds, designed to eliminate exposure to live
parts.
No Exposed Live Parts
LayerZero’s patent-pending Circuit Breaker Shrouds cover
exposed wiring, maximizing operator safety.
Wiring Without Shrouds Leaves Wiring Exposed Circuit Breaker Shrouds Maximize Operator Safety
Wall-Mounted Power PanelSeries 70 ePanel-2
8 © Copyright 2016 LayerZero Power Systems, Inc.
Safety Features
The LayerZero Finger-Safe SafePanel™
The Series 70 eRPP features an IP-20, finger-safe panel board, meaning
that the opening will not allow ingress of ½” (12.5mm) diameter probe,
for maximum operator safety.
An arc can form as two live conductors are separated – such as the
removal of a circuit breaker from a panel board. The SafePanel design
ensures that a potential arc would be contained in the connection well
so that even if a branch breaker were to be removed, the arc would be
contained in the connection well.
Insulated with the components deeply isolated, removal of the breaker
is safe and easy.
Isolated, Non-Conducting Brass Screws
The Protective Cover Is Removed The Breaker Is Inserted Into The Opening
The Breaker Snaps Into The DIN Rail The Breaker Is Secured With An Isolated,
Non Conducting Screw
Wall-Mounted Power PanelSeries 70 ePanel-2
9 © Copyright 2016 LayerZero Power Systems, Inc.
Safety Features
Modbus/TCP http:// through a
standard web browser
Simple Network
Management Protocol
(SNMP)
Standard
Ethernet
Dry Contacts
• Meters
• Alarms
• Alarms • Alarms• Panel
Setup
• Meters
• Alarms
• Waveforms
• History/Event Log
• Diagnostics
Series 70
ePanel
Bluetooth Keeps Circuit Level Information Up-To-Date
Coordinate efforts to keep panel board naming conventions accurate
and up-to-date with Bluetooth connectivity. In critical facilities,
Facilities typically install the physical circuit breakers, while IT workers
manage naming of panel designations.
With Bluetooth connectivity, the naming, size, and assignment of
circuit breakers can be taken care of at the point-of-impact, bringing
together the efforts of facilities and IT for more accurate deployment.
Wall-Mounted Power PanelSeries 70 ePanel-2
10 © Copyright 2016 LayerZero Power Systems, Inc.
Connectivity Options
The Series 70 ePanel-2 is equipped with Zen DPQM (Distribution
Power Quality Monitoring), an all encompassing monitoring
system with local and remote communications options.
From basic monitoring & alarm reporting, to advanced power
quality monitoring functionality, Zen DPQM provides a wide-range
of options to help you be aware, be vigilant, be proactive in your
quest to create a safe, stable and reliable operation.
Zen DPQM Provides Answers
Zen DPQM provides timestamped pictures of waveforms before and after events, providing information that enables facilities to go
back in time to methodically identify and correct the root causes of events. Zen actively captures power quality information at the
STS, PDU, and RPP - permitting thorough post-event analysis.
6 Electrical Cycles 6 Electrical Cycles
Waveform Capture of Power Quality Issue
Trigger Event
Phase A
Phase B
Phase C
Wall-Mounted Power PanelSeries 70 ePanel-2
11 © Copyright 2016 LayerZero Power Systems, Inc.
Power Quality Monitoring
CB2
Panel 2
PBM
CB1
Inputs
Panel 1
A
V
PQ
Current Metering Point
Voltage Metering Point
Power Quality Metering Point
BM Branch Current Monitoring
Wall-Mounted Power PanelSeries 70 ePanel-2
12 © Copyright 2016 LayerZero Power Systems, Inc.
Power Quality Monitoring
Zen DPQM Parameters Mains
Subfeeds or Branch
Circuits
Voltage Monitor
Volts (L-L) Phase A/B/C (volts RMS)
Volts (L-N) Phase A/B/C (volts RMS)
Phase Rotation
Current Monitor
CT Reversed Phase A/B/C/N
Current Phase A/B/C/N (amperes RMS)
Power Monitor
Frequency (hertz)
Real Power (kilowatts)
Apparent Power (kilovolt-amperes)
Reactive Power (kilovolt-amperes reactive)
Power Factor
Energy (kilowatt-hours)
Block Demand (kilowatts)
Block Demand Peak (kilowatts)
Rolling Demand (kilowatts)
Rolling Demand Peak (kilowatts)
Power Quality
Percent VTHD (percent)
Waveform Capture
Alarms
Phase - Under Voltage A/B/C (Alarm)
Phase - Over Voltage A/B/C (Alarm)
Phase - Low Voltage A/B/C (Warning)
Phase - High Voltage A/B/C (Warning)
Phase - Over Current A/B/C (Alarm)
Phase - High Current A/B/C (Warning)
Under Frequency (Alarm)
Over Frequency (Alarm)
High VTHD (Warning)
Over VTHD (Alarm)
Phase Rotation (Alarm)
All product specifications are subject to change without notice.
Wall-Mounted Power PanelSeries 70 ePanel-2
13 © Copyright 2016 LayerZero Power Systems, Inc.
Technical Specifications
ePanel-2 Models with System Withstand Ratings
Presence of Main Circuit Breaker
120/208 V, 3-Phase, 4-Wire + Ground 35 kA
220/380 V, 3-Phase, 4-Wire + Ground
14 kA
230/400 V, 3-Phase, 4-Wire + Ground
240/415 V, 3-Phase, 4-Wire + Ground
277/480 V, 3-Phase, 4-Wire + Ground
480 V, 3-Phase, 3-Wire + Ground
Mechanical Characteristics
Dimensions 47”W x 80”H x 10.5”D (1193 mm W x 2032 mm H x 266.7 mm)
Weight 550 lbs (250 kg)
Enclosure Mounting Wall-Mounted
Frame Construction Welded Frame
Electrical Connections Flexible Laminated Bus, Silver-Plated Solid Busbar
Color Textured Powder Coat White (RAL 7035), Blue (RAL 5017), Black, Custom
Seismic Floor Anchors Optional
Seismic Floor Stand Optional
Sectionalization Engineered Composite Insulation, Dead Front Doors
Circuit Breaker Identification Labels Viewable Through Polycarbonate Window
Electrical Characteristics
Input Voltage
120/208 V, 3-Phase, 4-Wire + Ground; 220/380 V, 3-Phase, 4-Wire + Ground; 230/400 V, 3-Phase, 4-Wire + Ground;
240/415 V, 3-Phase, 4-Wire + Ground; 277/480 V, 3-Phase, 4-Wire + Ground; 480 V, 3-Phase, 3-Wire + Ground
Configuration
1 Input, 2 Panels 2 Inputs, 2 Panels
Parallel (P), Shared Parallel (SP) Dedicated (D), Feed Through (FT)
Frequency 50 Hz, 60 Hz
Poles 3-pole, 4-pole
Input Feeder Termination Single, Mechanical; Dual, Mechanical; Two-Hole, Compression
Phases 3-Phase, 3-Wire (Input); 3-Phase, 4-Wire + Ground (Output)
Neutral Rating 100%, 200%
Circuit Breaker Mounting Type Fixed, Plug-In
Distribution SafePanel™ Distribution
Number of Output CBs 84-Circuit
Power Quality Monitoring
Power Quality Monitoring Technology Zen DPQM™ (Distribution Power Quality Monitoring)
Waveform Capture Local Display, Remote Display via Web Browser
All product specifications are subject to change without notice.
Wall-Mounted Power PanelSeries 70 ePanel-2
14 © Copyright 2016 LayerZero Power Systems, Inc.
Technical Specifications
Operational Characteristics
Cooling Convection Cooling
Cable Access Top/Bottom
Service Access Front Only Access
IR Scan Port Type InSight™ IR Portholes
Display Type 3.2” LCD with Membrane, 10.5” Color Touch Screen GUI (Optional)
Connectivity
Meters Local Display, Ethernet, Modbus/TCP, http via Web Browser (Non-Proprietary)
Alarms Local Display, Ethernet, Modbus/TCP, http via Web Browser (Non-Proprietary)
Summary Alarm Dry Contacts
Waveforms Local Display, Ethernet, http via Web Browser (Non-Proprietary)
History/Event Log Local Display, Ethernet, http via Web Browser (Non-Proprietary)
Diagnostics Local Display, Ethernet, http via Web Browser (Non-Proprietary)
Time Synchronization Network Time Protocol (NTP)
Standards Conformance
UL ETL and cETL listed to UL 60950
Contact LayerZero for custom sizes and designs.
All product specifications are subject to change without notice.
Wall-Mounted Power PanelSeries 70 ePanel-2
15 © Copyright 2016 LayerZero Power Systems, Inc.
Technical Specifications
LayerZero Power Systems, Inc.
1500 Danner Drive
Aurora, OH 44202 U.S.A.
© 2016 LayerZero Power Systems, Inc.
LayerZero Power Systems, LayerZero.com and the LayerZero logo are registered trademark of LayerZero.
All product specifications are subject to change without notice.
Learn more at www.LayerZero.com
Rev. 7/16 #16

More Related Content

What's hot

Rfs7000 series switch installation guide
Rfs7000 series switch installation guideRfs7000 series switch installation guide
Rfs7000 series switch installation guide
Advantec Distribution
 
Motorola rfs6000 series rf switch installation guide
Motorola rfs6000 series rf switch installation guideMotorola rfs6000 series rf switch installation guide
Motorola rfs6000 series rf switch installation guide
Advantec Distribution
 
Data sheet en_us_1872223499
Data sheet en_us_1872223499Data sheet en_us_1872223499
Data sheet en_us_1872223499
amthanhbosch
 
Inetsis EN catalogo
Inetsis EN catalogoInetsis EN catalogo
Inetsis EN catalogo
Redondo Luis
 

What's hot (20)

LayerZero Series 70: eRPP-FS Front/Side Access Remote Power Panel
LayerZero Series 70: eRPP-FS Front/Side Access Remote Power PanelLayerZero Series 70: eRPP-FS Front/Side Access Remote Power Panel
LayerZero Series 70: eRPP-FS Front/Side Access Remote Power Panel
 
85 0135 b-installation manual_web
85 0135 b-installation manual_web85 0135 b-installation manual_web
85 0135 b-installation manual_web
 
Rfs7000 series switch installation guide
Rfs7000 series switch installation guideRfs7000 series switch installation guide
Rfs7000 series switch installation guide
 
Motorola rfs6000 series rf switch installation guide
Motorola rfs6000 series rf switch installation guideMotorola rfs6000 series rf switch installation guide
Motorola rfs6000 series rf switch installation guide
 
Powerlink® G3 Lighting Control Systems
Powerlink® G3 Lighting Control SystemsPowerlink® G3 Lighting Control Systems
Powerlink® G3 Lighting Control Systems
 
2012 UH-HNEI Smart Grid Inverter Project System Architecture
2012 UH-HNEI Smart Grid Inverter Project System Architecture2012 UH-HNEI Smart Grid Inverter Project System Architecture
2012 UH-HNEI Smart Grid Inverter Project System Architecture
 
Access control basics-9
Access control basics-9Access control basics-9
Access control basics-9
 
Sd355
Sd355Sd355
Sd355
 
LayerZero Series 70 ePODs: Type-N Static Transfer Switch with Distribution
LayerZero Series 70 ePODs: Type-N Static Transfer Switch with DistributionLayerZero Series 70 ePODs: Type-N Static Transfer Switch with Distribution
LayerZero Series 70 ePODs: Type-N Static Transfer Switch with Distribution
 
Pepperl fuchs 2011 Emerson Global Users Exchange Intrinsically Safe CHARMS S...
Pepperl fuchs 2011 Emerson Global Users Exchange  Intrinsically Safe CHARMS S...Pepperl fuchs 2011 Emerson Global Users Exchange  Intrinsically Safe CHARMS S...
Pepperl fuchs 2011 Emerson Global Users Exchange Intrinsically Safe CHARMS S...
 
Widom smart double_switch_l_en
Widom smart double_switch_l_enWidom smart double_switch_l_en
Widom smart double_switch_l_en
 
Optoacoplador 817a
Optoacoplador  817aOptoacoplador  817a
Optoacoplador 817a
 
Vlfvic010
Vlfvic010Vlfvic010
Vlfvic010
 
Data sheet en_us_1872223499
Data sheet en_us_1872223499Data sheet en_us_1872223499
Data sheet en_us_1872223499
 
85 0100 b-rev 3_univ air installation_web
85 0100 b-rev 3_univ air installation_web85 0100 b-rev 3_univ air installation_web
85 0100 b-rev 3_univ air installation_web
 
Inetsis EN catalogo
Inetsis EN catalogoInetsis EN catalogo
Inetsis EN catalogo
 
Acb1
Acb1Acb1
Acb1
 
Integrating Speed and Flexibility Isolating Industrial Control
Integrating Speed and Flexibility Isolating Industrial ControlIntegrating Speed and Flexibility Isolating Industrial Control
Integrating Speed and Flexibility Isolating Industrial Control
 
Cfs0065 ccat-r1-4 part7
Cfs0065 ccat-r1-4 part7Cfs0065 ccat-r1-4 part7
Cfs0065 ccat-r1-4 part7
 
Vertx v200 ds_en
Vertx v200 ds_enVertx v200 ds_en
Vertx v200 ds_en
 

Similar to LayerZero Series 70: ePanel-2 Wall-Mounted Power Panel

WM Siemens IEC 61850 Flyer 081914
WM Siemens IEC 61850 Flyer 081914WM Siemens IEC 61850 Flyer 081914
WM Siemens IEC 61850 Flyer 081914
Ryan Bolduc, PE
 
Condor St30 Specification
Condor St30 SpecificationCondor St30 Specification
Condor St30 Specification
Krdenas
 

Similar to LayerZero Series 70: ePanel-2 Wall-Mounted Power Panel (20)

LayerZero Series 70 ePODs: Type-P Power Distribution Unit with Transformer an...
LayerZero Series 70 ePODs: Type-P Power Distribution Unit with Transformer an...LayerZero Series 70 ePODs: Type-P Power Distribution Unit with Transformer an...
LayerZero Series 70 ePODs: Type-P Power Distribution Unit with Transformer an...
 
LayerZero Series 70 ePODs: Dual Type-P
LayerZero Series 70 ePODs: Dual Type-PLayerZero Series 70 ePODs: Dual Type-P
LayerZero Series 70 ePODs: Dual Type-P
 
Ats brochure
Ats brochureAts brochure
Ats brochure
 
Gemini_3__3008_web
Gemini_3__3008_webGemini_3__3008_web
Gemini_3__3008_web
 
01. sentron 3 wl brochure
01. sentron 3 wl brochure01. sentron 3 wl brochure
01. sentron 3 wl brochure
 
LayerZero Series 70 ePODs: Type-S (Power Distribution Unit)
LayerZero Series 70 ePODs: Type-S (Power Distribution Unit)LayerZero Series 70 ePODs: Type-S (Power Distribution Unit)
LayerZero Series 70 ePODs: Type-S (Power Distribution Unit)
 
WM Siemens IEC 61850 Flyer 081914
WM Siemens IEC 61850 Flyer 081914WM Siemens IEC 61850 Flyer 081914
WM Siemens IEC 61850 Flyer 081914
 
Littelfuse Solutions for Security Cameras and Video Doorbells
Littelfuse Solutions for Security Cameras and Video DoorbellsLittelfuse Solutions for Security Cameras and Video Doorbells
Littelfuse Solutions for Security Cameras and Video Doorbells
 
LayerZero Series 70: eSTS Static Transfer Switch 150 A - 1200 A
LayerZero Series 70: eSTS Static Transfer Switch 150 A - 1200 A LayerZero Series 70: eSTS Static Transfer Switch 150 A - 1200 A
LayerZero Series 70: eSTS Static Transfer Switch 150 A - 1200 A
 
DETECTING POWER GRID SYNCHRONISATION FAILURE ON SENSING BAD VOLTAGE OR FREQUE...
DETECTING POWER GRID SYNCHRONISATION FAILURE ON SENSING BAD VOLTAGE OR FREQUE...DETECTING POWER GRID SYNCHRONISATION FAILURE ON SENSING BAD VOLTAGE OR FREQUE...
DETECTING POWER GRID SYNCHRONISATION FAILURE ON SENSING BAD VOLTAGE OR FREQUE...
 
SebKMT Cable Sheath testers & Fault Locators
SebKMT Cable Sheath testers & Fault LocatorsSebKMT Cable Sheath testers & Fault Locators
SebKMT Cable Sheath testers & Fault Locators
 
Dtmf based home device
Dtmf based home deviceDtmf based home device
Dtmf based home device
 
LayerZero 4-Pole eSTS Static Transfer Switch with SafePanel Distribution
LayerZero 4-Pole eSTS Static Transfer Switch with SafePanel DistributionLayerZero 4-Pole eSTS Static Transfer Switch with SafePanel Distribution
LayerZero 4-Pole eSTS Static Transfer Switch with SafePanel Distribution
 
Micro Scanner2 - Raising Cable Verification to a Higher Power
Micro Scanner2 - Raising Cable Verification to a Higher PowerMicro Scanner2 - Raising Cable Verification to a Higher Power
Micro Scanner2 - Raising Cable Verification to a Higher Power
 
Implementation of Transformer Protection by Intelligent Electronic Device for...
Implementation of Transformer Protection by Intelligent Electronic Device for...Implementation of Transformer Protection by Intelligent Electronic Device for...
Implementation of Transformer Protection by Intelligent Electronic Device for...
 
LayerZero Series 70: eSTS Static Transfer Switch 1600 A - 4000 A
LayerZero Series 70: eSTS Static Transfer Switch 1600 A - 4000 A LayerZero Series 70: eSTS Static Transfer Switch 1600 A - 4000 A
LayerZero Series 70: eSTS Static Transfer Switch 1600 A - 4000 A
 
Sa*ple
Sa*pleSa*ple
Sa*ple
 
Iskra Medium Voltage Automation and Protection (Protection relays)
Iskra Medium Voltage Automation and Protection (Protection relays)Iskra Medium Voltage Automation and Protection (Protection relays)
Iskra Medium Voltage Automation and Protection (Protection relays)
 
Condor St30 Specification
Condor St30 SpecificationCondor St30 Specification
Condor St30 Specification
 
Cataloge ge 2.industrial components-2_entelli_guard
Cataloge ge 2.industrial components-2_entelli_guardCataloge ge 2.industrial components-2_entelli_guard
Cataloge ge 2.industrial components-2_entelli_guard
 

Recently uploaded

Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire business
panagenda
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Safe Software
 
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Victor Rentea
 
Architecting Cloud Native Applications
Architecting Cloud Native ApplicationsArchitecting Cloud Native Applications
Architecting Cloud Native Applications
WSO2
 

Recently uploaded (20)

Exploring Multimodal Embeddings with Milvus
Exploring Multimodal Embeddings with MilvusExploring Multimodal Embeddings with Milvus
Exploring Multimodal Embeddings with Milvus
 
CNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In PakistanCNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In Pakistan
 
MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024
 
API Governance and Monetization - The evolution of API governance
API Governance and Monetization -  The evolution of API governanceAPI Governance and Monetization -  The evolution of API governance
API Governance and Monetization - The evolution of API governance
 
AI+A11Y 11MAY2024 HYDERBAD GAAD 2024 - HelloA11Y (11 May 2024)
AI+A11Y 11MAY2024 HYDERBAD GAAD 2024 - HelloA11Y (11 May 2024)AI+A11Y 11MAY2024 HYDERBAD GAAD 2024 - HelloA11Y (11 May 2024)
AI+A11Y 11MAY2024 HYDERBAD GAAD 2024 - HelloA11Y (11 May 2024)
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
 
Six Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal OntologySix Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal Ontology
 
How to Check CNIC Information Online with Pakdata cf
How to Check CNIC Information Online with Pakdata cfHow to Check CNIC Information Online with Pakdata cf
How to Check CNIC Information Online with Pakdata cf
 
AI in Action: Real World Use Cases by Anitaraj
AI in Action: Real World Use Cases by AnitarajAI in Action: Real World Use Cases by Anitaraj
AI in Action: Real World Use Cases by Anitaraj
 
Understanding the FAA Part 107 License ..
Understanding the FAA Part 107 License ..Understanding the FAA Part 107 License ..
Understanding the FAA Part 107 License ..
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire business
 
Platformless Horizons for Digital Adaptability
Platformless Horizons for Digital AdaptabilityPlatformless Horizons for Digital Adaptability
Platformless Horizons for Digital Adaptability
 
Introduction to use of FHIR Documents in ABDM
Introduction to use of FHIR Documents in ABDMIntroduction to use of FHIR Documents in ABDM
Introduction to use of FHIR Documents in ABDM
 
Less Is More: Utilizing Ballerina to Architect a Cloud Data Platform
Less Is More: Utilizing Ballerina to Architect a Cloud Data PlatformLess Is More: Utilizing Ballerina to Architect a Cloud Data Platform
Less Is More: Utilizing Ballerina to Architect a Cloud Data Platform
 
JavaScript Usage Statistics 2024 - The Ultimate Guide
JavaScript Usage Statistics 2024 - The Ultimate GuideJavaScript Usage Statistics 2024 - The Ultimate Guide
JavaScript Usage Statistics 2024 - The Ultimate Guide
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
 
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
 
Architecting Cloud Native Applications
Architecting Cloud Native ApplicationsArchitecting Cloud Native Applications
Architecting Cloud Native Applications
 
WSO2's API Vision: Unifying Control, Empowering Developers
WSO2's API Vision: Unifying Control, Empowering DevelopersWSO2's API Vision: Unifying Control, Empowering Developers
WSO2's API Vision: Unifying Control, Empowering Developers
 

LayerZero Series 70: ePanel-2 Wall-Mounted Power Panel

  • 1. Series 70 ePanel-2 Wall-Mounted Remote Power Panel The Foundation Layer Product Brochure
  • 2. ePanel: Save Space, Increase Safety, And Maximize Reliability ePanel Uses A Wall-Mounted Design To Maximize The Effectiveness Of Critical Floor Space Web-enabled Series 70: ePanel-2 Wall-Mounted Distribution Panels save space. ePanel is highly configurable to meet a variety of business goals, and can be installed at the end of server rows or on the walls. The ePanel utilizes the IP-20 finger-safe SafePanel™, requires Category-0 PPE, provides selective trip coordination to 35 kAIC, enables Bluetooth connectivity, contains waveform capture on every breaker, with Modbus/TCP, SNMP, HTTP web browsing protocols supported. Wall-Mounted Power PanelSeries 70 ePanel-2 2 © Copyright 2016 LayerZero Power Systems, Inc.
  • 3. LayerZero’s ePanel-2 Product Features ;; Silver Plated Input Terminals: Silver Has Excellent Conductivity To Provide Superior Electrical Performance and Reliability ;; Machined Hardware: Machined Cap Screws and Engineered Disc Springs Maintain Constant Torque Throughout Product Life ;; Convection Cooling: Natural Convection-Cooled Heat Dissipation System is Maintenance-Free ;; Serialized Critical Board Tracking: Critical Boards Are Serialized And Cataloged in an Active Database For Traceability ;; Selective Trip Coordination: Main Breaker Will Not Trip In The Event of a Downstream Fault. Reliability Safety ;; InSight™ IR Portholes: Bolted Connections Can Be IR Scanned With the Dead-Front Doors Closed ;; Sectionalized Components: Separations Between Each Section To Maintain Maximum Operator Safety ;; Polycarbonate Windows: Allows Circuit Breaker Positions Viewed With The Dead-Front Door Closed ;; Dead Front Hinged Doors: Barrier To Provide A Safe Working Area With No Exposed Live Parts ;; Guided Wireways: Helps Keep Wires Organized Connectivity ;; Ethernet Connectivity: Secure VPN Router Connects To Network For Advanced Remote Monitoring Capabilities ;; Modbus/TCP: Open Connectivity to Existing Monitoring Systems Without Proprietary Limitations ;; NTP Time Clock Synchronization: Facilitates Timeline-Based Logging For Post-Event Reconstruction ;; SNMP Connectivity: Permits Remote Management Via Simple Network Management Protocol ;; Bluetooth Connectivity: Wirelessly Set Up Panels At The Point-Of-Impact ;; Real-Time Waveform Capture: Automatically Captures A Picture Of The Power Six-Cycles Before and After Every Event ;; Optional Local Touch-Screen Interface: Password-Protected Color Touch-Screen GUI For Local ePODs Setup/Operation ;; Black-Box Forensics: ePanel-2 Captures and Records Events To Provide Vital Information In Root-Cause Analysis Wall-Mounted Power PanelSeries 70 ePanel-2 3 © Copyright 2016 LayerZero Power Systems, Inc.
  • 4. Polycarbonate Window to view Circuit Breaker Positions InSight™ IR Portholes to Thermal Scan Bolted Connections Compression Connections at Input Feeder Flexible Laminated Bus for Higher Reliability Two 42-Circuit SafePanel™ Panel Boards Guided Wireways for Organized Cabling Circuit Breaker Designation Cards ePanel-2 input Is Supplied from STS Output Wall-Mounted Power PanelSeries 70 ePanel-2 4 © Copyright 2016 LayerZero Power Systems, Inc. Equipment Layout
  • 5. Serialized circuit boards We serialize and track all critical circuit boards and memory cards through our eBOSS portal, which allows customers to reference which components their machines are made from, who tested the components, as well as the ability to view notes generated from testing. Serialized components offer the ability to drill-down on prospective component failure utilizing predictive modeling techniques, so if part fails, the instance can be cross-referenced with similar parts. This preventative maintenance helps ensure maximum uptime. Sectionalized Components Help Maximize Operator Safety Operators are well-protected from exposed connections. There is a physical separation between the main circuit breaker(s) and branch circuit breakers. All connections are optically isolated to minimize risk. Polycarbonate windows are utilized to permit visibility and maximize operator safety. Energized parts are all insulated, covered, recessed, &/or internally mounted for safer operation of the unit. In addition, sections that isolate machine components are insulated. Wall-Mounted Power PanelSeries 70 ePanel-2 5 © Copyright 2016 LayerZero Power Systems, Inc. Reliability Features
  • 6. Selective Trip Coordination LayerZero Series 70 ePanel-2 Wall-Mounted Power Panels are selective trip coordinated. Selective Trip Coordination ensures that the main breaker will remain unaffected by the branch circuit breakers in the event of a downstream fault. The Fault Current Opens the Solenoid Magnet, Causing The Contacts To Part Unequal Pressure on Each Side of The Arc Causes the Plasma Wave To Rotate Away From The Contacts The Plasma Wave is Driven into 12 Evenly Spaced Dividers The Plasma is Rapidly Cooled Transient Voltage Attempts To Re- Strike The Arc, But The Plasma Is Again Pushed Into The Dividers When Sufficiently Cool, Charged Particles Recombine And The Fault Current Is Stopped Quickly & Safely Wall-Mounted Power PanelSeries 70 ePanel-2 6 © Copyright 2016 LayerZero Power Systems, Inc. Reliability Features
  • 7. 77 Scan Bolted Connections with Dead-Front Doors Closed The left inner dead-front doors contain strategically positioned IR-scan portholes to enable safe thermal scanning of all bolted connections with the deadfront closed, without exposing the operator to power circuit voltage. The IR window swivels upward and unlocks with key-hole access to reveal a mesh, allowing the operator to point-and-shoot thermal cameras to obtain accurate readings. LayerZero provides documentation for proper thermal scanning procedures. Polycarbonate Windows The Series 70: ePanel-2 is equipped with polycarbonate windows located on the outer doors. Circuit breaker positions can be viewed with the dead-front doors closed. In addition, a hinged polycarbonate window on the input terminals increases safety by eliminating exposure to live bus. Wall-Mounted Power PanelSeries 70 ePanel-2 7 © Copyright 2016 LayerZero Power Systems, Inc. Ease of Maintenance/Safety Features
  • 8. Circuit Breaker Shrouds LayerZero Series 70 ePanel-2 Power Panel provides optional circuit breaker shrouds, designed to eliminate exposure to live parts. No Exposed Live Parts LayerZero’s patent-pending Circuit Breaker Shrouds cover exposed wiring, maximizing operator safety. Wiring Without Shrouds Leaves Wiring Exposed Circuit Breaker Shrouds Maximize Operator Safety Wall-Mounted Power PanelSeries 70 ePanel-2 8 © Copyright 2016 LayerZero Power Systems, Inc. Safety Features
  • 9. The LayerZero Finger-Safe SafePanel™ The Series 70 eRPP features an IP-20, finger-safe panel board, meaning that the opening will not allow ingress of ½” (12.5mm) diameter probe, for maximum operator safety. An arc can form as two live conductors are separated – such as the removal of a circuit breaker from a panel board. The SafePanel design ensures that a potential arc would be contained in the connection well so that even if a branch breaker were to be removed, the arc would be contained in the connection well. Insulated with the components deeply isolated, removal of the breaker is safe and easy. Isolated, Non-Conducting Brass Screws The Protective Cover Is Removed The Breaker Is Inserted Into The Opening The Breaker Snaps Into The DIN Rail The Breaker Is Secured With An Isolated, Non Conducting Screw Wall-Mounted Power PanelSeries 70 ePanel-2 9 © Copyright 2016 LayerZero Power Systems, Inc. Safety Features
  • 10. Modbus/TCP http:// through a standard web browser Simple Network Management Protocol (SNMP) Standard Ethernet Dry Contacts • Meters • Alarms • Alarms • Alarms• Panel Setup • Meters • Alarms • Waveforms • History/Event Log • Diagnostics Series 70 ePanel Bluetooth Keeps Circuit Level Information Up-To-Date Coordinate efforts to keep panel board naming conventions accurate and up-to-date with Bluetooth connectivity. In critical facilities, Facilities typically install the physical circuit breakers, while IT workers manage naming of panel designations. With Bluetooth connectivity, the naming, size, and assignment of circuit breakers can be taken care of at the point-of-impact, bringing together the efforts of facilities and IT for more accurate deployment. Wall-Mounted Power PanelSeries 70 ePanel-2 10 © Copyright 2016 LayerZero Power Systems, Inc. Connectivity Options
  • 11. The Series 70 ePanel-2 is equipped with Zen DPQM (Distribution Power Quality Monitoring), an all encompassing monitoring system with local and remote communications options. From basic monitoring & alarm reporting, to advanced power quality monitoring functionality, Zen DPQM provides a wide-range of options to help you be aware, be vigilant, be proactive in your quest to create a safe, stable and reliable operation. Zen DPQM Provides Answers Zen DPQM provides timestamped pictures of waveforms before and after events, providing information that enables facilities to go back in time to methodically identify and correct the root causes of events. Zen actively captures power quality information at the STS, PDU, and RPP - permitting thorough post-event analysis. 6 Electrical Cycles 6 Electrical Cycles Waveform Capture of Power Quality Issue Trigger Event Phase A Phase B Phase C Wall-Mounted Power PanelSeries 70 ePanel-2 11 © Copyright 2016 LayerZero Power Systems, Inc. Power Quality Monitoring
  • 12. CB2 Panel 2 PBM CB1 Inputs Panel 1 A V PQ Current Metering Point Voltage Metering Point Power Quality Metering Point BM Branch Current Monitoring Wall-Mounted Power PanelSeries 70 ePanel-2 12 © Copyright 2016 LayerZero Power Systems, Inc. Power Quality Monitoring
  • 13. Zen DPQM Parameters Mains Subfeeds or Branch Circuits Voltage Monitor Volts (L-L) Phase A/B/C (volts RMS) Volts (L-N) Phase A/B/C (volts RMS) Phase Rotation Current Monitor CT Reversed Phase A/B/C/N Current Phase A/B/C/N (amperes RMS) Power Monitor Frequency (hertz) Real Power (kilowatts) Apparent Power (kilovolt-amperes) Reactive Power (kilovolt-amperes reactive) Power Factor Energy (kilowatt-hours) Block Demand (kilowatts) Block Demand Peak (kilowatts) Rolling Demand (kilowatts) Rolling Demand Peak (kilowatts) Power Quality Percent VTHD (percent) Waveform Capture Alarms Phase - Under Voltage A/B/C (Alarm) Phase - Over Voltage A/B/C (Alarm) Phase - Low Voltage A/B/C (Warning) Phase - High Voltage A/B/C (Warning) Phase - Over Current A/B/C (Alarm) Phase - High Current A/B/C (Warning) Under Frequency (Alarm) Over Frequency (Alarm) High VTHD (Warning) Over VTHD (Alarm) Phase Rotation (Alarm) All product specifications are subject to change without notice. Wall-Mounted Power PanelSeries 70 ePanel-2 13 © Copyright 2016 LayerZero Power Systems, Inc. Technical Specifications
  • 14. ePanel-2 Models with System Withstand Ratings Presence of Main Circuit Breaker 120/208 V, 3-Phase, 4-Wire + Ground 35 kA 220/380 V, 3-Phase, 4-Wire + Ground 14 kA 230/400 V, 3-Phase, 4-Wire + Ground 240/415 V, 3-Phase, 4-Wire + Ground 277/480 V, 3-Phase, 4-Wire + Ground 480 V, 3-Phase, 3-Wire + Ground Mechanical Characteristics Dimensions 47”W x 80”H x 10.5”D (1193 mm W x 2032 mm H x 266.7 mm) Weight 550 lbs (250 kg) Enclosure Mounting Wall-Mounted Frame Construction Welded Frame Electrical Connections Flexible Laminated Bus, Silver-Plated Solid Busbar Color Textured Powder Coat White (RAL 7035), Blue (RAL 5017), Black, Custom Seismic Floor Anchors Optional Seismic Floor Stand Optional Sectionalization Engineered Composite Insulation, Dead Front Doors Circuit Breaker Identification Labels Viewable Through Polycarbonate Window Electrical Characteristics Input Voltage 120/208 V, 3-Phase, 4-Wire + Ground; 220/380 V, 3-Phase, 4-Wire + Ground; 230/400 V, 3-Phase, 4-Wire + Ground; 240/415 V, 3-Phase, 4-Wire + Ground; 277/480 V, 3-Phase, 4-Wire + Ground; 480 V, 3-Phase, 3-Wire + Ground Configuration 1 Input, 2 Panels 2 Inputs, 2 Panels Parallel (P), Shared Parallel (SP) Dedicated (D), Feed Through (FT) Frequency 50 Hz, 60 Hz Poles 3-pole, 4-pole Input Feeder Termination Single, Mechanical; Dual, Mechanical; Two-Hole, Compression Phases 3-Phase, 3-Wire (Input); 3-Phase, 4-Wire + Ground (Output) Neutral Rating 100%, 200% Circuit Breaker Mounting Type Fixed, Plug-In Distribution SafePanel™ Distribution Number of Output CBs 84-Circuit Power Quality Monitoring Power Quality Monitoring Technology Zen DPQM™ (Distribution Power Quality Monitoring) Waveform Capture Local Display, Remote Display via Web Browser All product specifications are subject to change without notice. Wall-Mounted Power PanelSeries 70 ePanel-2 14 © Copyright 2016 LayerZero Power Systems, Inc. Technical Specifications
  • 15. Operational Characteristics Cooling Convection Cooling Cable Access Top/Bottom Service Access Front Only Access IR Scan Port Type InSight™ IR Portholes Display Type 3.2” LCD with Membrane, 10.5” Color Touch Screen GUI (Optional) Connectivity Meters Local Display, Ethernet, Modbus/TCP, http via Web Browser (Non-Proprietary) Alarms Local Display, Ethernet, Modbus/TCP, http via Web Browser (Non-Proprietary) Summary Alarm Dry Contacts Waveforms Local Display, Ethernet, http via Web Browser (Non-Proprietary) History/Event Log Local Display, Ethernet, http via Web Browser (Non-Proprietary) Diagnostics Local Display, Ethernet, http via Web Browser (Non-Proprietary) Time Synchronization Network Time Protocol (NTP) Standards Conformance UL ETL and cETL listed to UL 60950 Contact LayerZero for custom sizes and designs. All product specifications are subject to change without notice. Wall-Mounted Power PanelSeries 70 ePanel-2 15 © Copyright 2016 LayerZero Power Systems, Inc. Technical Specifications
  • 16. LayerZero Power Systems, Inc. 1500 Danner Drive Aurora, OH 44202 U.S.A. © 2016 LayerZero Power Systems, Inc. LayerZero Power Systems, LayerZero.com and the LayerZero logo are registered trademark of LayerZero. All product specifications are subject to change without notice. Learn more at www.LayerZero.com Rev. 7/16 #16