++++General,
XGN17-40.5 box type fixed AC metal clad switchgear according to
IEC62271-200 design. It can be used in three-phase AC rated frequency 50Hz
single bus and single busbar with bypass system of indoor complete sets of
equipment, as the acceptance and distribution of 35kV electric network with and
has the circuit control, protection and monitoring the function.
++++Service environment
1 ambient air temperature limit: +40 C, lower limit: -10 C, the daily average
temperature of not more than 35;
2 altitude is not more than 1000m;
3 the relative ambient temperature is not more than 95%, the average monthly is
not more than 90%;
4 earthquake intensity is not more than 8;
5 the average value of water vapor pressure is not more than 2.2Kpa, the
monthly average value is no more than 1.8kpa;
6 no fire, explosion hazards, serious pollution, chemical corrosion and violent
place of this building.
Special working conditions
In the case of more than the normal use of the environment under the conditions,
by the user and the manufacturer.
++++Feature
XGN17-40.5 box type fixed AC metal clad switchgear device is fixed arranged
composite structure and its basic skeleton steel and steel plate bending parts by
welding and, the cabinet body shell is IP2X level of protection. Mainly by the
cabinet and the cabinet after assembly and made the switch equipment, uses a
different set corresponding to a functional unit, cabinet between the charged
body were to air main insulation and the charged body between and the relative
between the insulation distance of not less than 300mm. 1) before the cabinet:
before the cabinet set up main busbar and busbar disconnector chamber, a
circuit breaker chamber, relay room, main busbar and busbar disconnector
chamber at the top of the cabinet, the circuit breaker room arranged at the
bottom of the cabinet, the chamber is also provided with a current mutual
inductor, two rooms have insulation plates separated. Through the bus bar
casing connected. Relay settings in the cabinet is the front of the middle, small
bus terminal 15 day, and a second cable channel, terminal room located in the
left door, can install JH10 terminals more than 80, at the bottom of the chamber
is also provided M12 connection bolt for auxiliary circuit connected to use, right
door for dimensional repair channel. The upper part of the terminal chamber is
an operating panel, and can be provided with an auxiliary switch. 2) after the
cabinet: after the cabinet bolts with a cabinet is connected, the cabinet according
to need can be set to bypass bus and isolating switch, an overhead pass in and
out line from the cabinet by, set the bypass bus, overhead line and the reach the
safe height, need to add a small attached or obscuration network. When the
mother is not set, the overhead outlet can be passed from the top of the back
cabinet. The cabinet can also be installed with a voltage transformer or a
lightning arrester, and the contact bus and the cable outlet are installed in the
cabinet. The back door bolt is fixed, if the charged display prompt no electricity,
can open the back door, the main bus room and after the cabinet are separated
by a baffle plate
++++ Main technical specifications
No Item Unit Data
1 Rated voltage kV 30/33/40.5
2 Rated current Hz 50/60
3
Rated insulation level lightning impulse voltage kV 185
Power frequency impulse
voltage
kV 95
4 Rated current A 630/1250/16
00/2000
5 Rated thermal stability current KA/4
S
31.5
6
Rated dynamic stability current kA 63
7 Rated short circuit breaking current kA 25
8 Rated short circuit current (KA) kA 63
9 Rated voltage, switch and auxiliary circuit V DC 24, 36,
48,110,220
10 protection class
IP2X
++++structure
HXGN17 series metal clad switchgear usef high voltage vacuum load switch and
fuse combination vacuum load switch for incoming and outgoing protectiot, which
is suitable for the three phase AC 50HZ,uo to 40.5kV power system, or with sets
of power distribution equipment and ring main unit switch cabinet, combined AC
power plants and other supporting the use, widely used in wind power generation,
city network construction and transformation project, industrial and mining
enterprises, high-rise buildings and public facilities can be as a ring network
power supply unit or terminal equipment, power distribution, control and
protection. The technical performance of the product is in line with the
IEC62271-100
The product has the advantages of high breaking capacity, safety and reliability,
long service life, frequent operation, compact structure, small volume, light
weight, no need of maintenance and the like. With breaking rated current,
overload current, short circuit current and prevent defect running of the
equipment, the switch has obvious isolating fracture loading with the closing
capacity ground off and electric spring mechanism, remote remote control
capability
++++Use condition
3.1 ambient air temperature does not exceed 40 degrees, and the
average 24h measured and does not exceed 35 degrees, low ambient air
temperature of -25;
3.2 the effect of sun radiation can be ignored;
3.3 altitude is not more than 1000m;
3.4 ambient air is not significantly contaminated by dust, smoke,
corrosion, corrosion, or flammable gas, steam or salt mist;
3.5 relative humidity, average plant does not exceed 95%; the vapor
pressure of water on average less than 22kPa; lunar humidity on
average no more than 90%;
The average monthly water vapor pressure is not more than 1.8KPa;
3.6 from the switchgear and control equipment of external vibration or
earthquake can be ignored;
3.7 the magnitude of the electromagnetic interference in the two system
is not more than 1.6kV.
++++ Technical parameters
4.1 main technical parameters of combined electric appliance
Technical parameters of vacuum load switch assembly and adjustment
in 4.2 combined electric appliance
4.3 the technical parameters of the assembly and adjustment of the
isolating switch assembled by the combined electric appliance
4.4 the technical parameters of the assembly and adjustment of the
grounding switch of the combined electric appliance
4.5 the technical parameters of fuse fuse
5 structure and working principle
++++ Structure
Combination of electrical appliances for triode linked structure: mainly
composed of a frame, a vacuum interrupter, isolating switch with fuse),
grounding switch and a spring operating mechanism, isolating switch
and vacuum arc arc and earthing switch through the insulator is fixed on
the frame and spring operating moving mechanism is arranged in the
frame on the side panel.
++++ Working Principle
Operation of 5.2.1 vacuum arc extinguishing chamber
Vacuum switchgear destroy the mode of operation of the arc chamber
using electric spring operation mechanism for closing, with tripping
electromagnet of gate, for manual closing. The opening operation,
manual closing operating handle clockwise spring operating mechanism
transmission shaft.
5.2.2 isolation switch, grounding switch, closing operation
A reliable mechanical interlocking device is arranged between the three
electric appliances of the vacuum arc extinguishing chamber, the
isolating switch and the grounding switch, and the isolating switch and
the grounding switch are operated by the same shaft. When the switch
closed, after the vacuum load switch. On the contrary, when the vacuum
load switch is in the state of switch, the switch and the grounding switch
can be operated.
5.2.3 fuse impact release switch
In the closing position of the combined electric and when the short
circuit current and overload current flows in the main circuit, at least one
phase fuse fuse.
Impactor action, brake speed depending on the size of current, current
divided brake speed faster, action of mechanical tripping device of the
combined electrical equipment, so that the vacuum arc extinguishing
chamber in a tripping spring achieve fast and reliable brake.
++++Before order pls clarify of your requirement with our tech
Copyright 2014 Farady Electric
Zhejiang Farady Electric Co.,Ltd
TEL:0086-577-61722510/61777258
Fax:0086-577-61777257
Http://www.farady-electric.com
Email:info@farady.cn
Add:Su’ao,Liushi,Yueqing,Zhejiang,P.R.China, 325604

More Related Content

What's hot

Asco issc-atex-intrinsically-safe-operator-hazardous-area-solenoid-valve-oper...
Asco issc-atex-intrinsically-safe-operator-hazardous-area-solenoid-valve-oper...Asco issc-atex-intrinsically-safe-operator-hazardous-area-solenoid-valve-oper...
Asco issc-atex-intrinsically-safe-operator-hazardous-area-solenoid-valve-oper...Thorne & Derrick UK
 
switchgear and protection by vala kamlesh
switchgear and protection by vala kamleshswitchgear and protection by vala kamlesh
switchgear and protection by vala kamleshKamlesh Vala
 
Richard Blakeley - Options for managing safety with elderly switchgear
Richard Blakeley - Options for managing safety with elderly switchgearRichard Blakeley - Options for managing safety with elderly switchgear
Richard Blakeley - Options for managing safety with elderly switchgearNSW Environment and Planning
 
Switchgear presentation
Switchgear presentationSwitchgear presentation
Switchgear presentationNikhil Kachare
 
Practical Power System Protection for Engineers and Technicians
Practical Power System Protection for Engineers and TechniciansPractical Power System Protection for Engineers and Technicians
Practical Power System Protection for Engineers and TechniciansLiving Online
 
Seminar presentation
Seminar presentationSeminar presentation
Seminar presentationRanjan kumar
 
Unit 04 Protection of generators and transformers
Unit  04 Protection of generators and transformers Unit  04 Protection of generators and transformers
Unit 04 Protection of generators and transformers PremanandDesai
 
Specification for electrical automation and instrumentation 02
Specification for electrical automation and instrumentation  02Specification for electrical automation and instrumentation  02
Specification for electrical automation and instrumentation 02Sajeewa Lakmal
 
1352 linear bv
1352   linear bv1352   linear bv
1352 linear bvchaitannya
 

What's hot (19)

Asco issc-atex-intrinsically-safe-operator-hazardous-area-solenoid-valve-oper...
Asco issc-atex-intrinsically-safe-operator-hazardous-area-solenoid-valve-oper...Asco issc-atex-intrinsically-safe-operator-hazardous-area-solenoid-valve-oper...
Asco issc-atex-intrinsically-safe-operator-hazardous-area-solenoid-valve-oper...
 
Introduction to mv switchgear
Introduction to mv switchgearIntroduction to mv switchgear
Introduction to mv switchgear
 
12777 coastal single pages part59
12777  coastal single pages part5912777  coastal single pages part59
12777 coastal single pages part59
 
EE6702 Protection and Switchgear notes R2013
EE6702 Protection and Switchgear notes R2013EE6702 Protection and Switchgear notes R2013
EE6702 Protection and Switchgear notes R2013
 
switchgear and protection by vala kamlesh
switchgear and protection by vala kamleshswitchgear and protection by vala kamlesh
switchgear and protection by vala kamlesh
 
Richard Blakeley - Options for managing safety with elderly switchgear
Richard Blakeley - Options for managing safety with elderly switchgearRichard Blakeley - Options for managing safety with elderly switchgear
Richard Blakeley - Options for managing safety with elderly switchgear
 
Switchgear presentation
Switchgear presentationSwitchgear presentation
Switchgear presentation
 
Switchgear
Switchgear Switchgear
Switchgear
 
RBM Type Outdoor metering unit catalog
RBM Type Outdoor metering unit catalogRBM Type Outdoor metering unit catalog
RBM Type Outdoor metering unit catalog
 
Bus Bar Protection
Bus Bar ProtectionBus Bar Protection
Bus Bar Protection
 
switchboards
switchboardsswitchboards
switchboards
 
Practical Power System Protection for Engineers and Technicians
Practical Power System Protection for Engineers and TechniciansPractical Power System Protection for Engineers and Technicians
Practical Power System Protection for Engineers and Technicians
 
Seminar presentation
Seminar presentationSeminar presentation
Seminar presentation
 
Fire alarm circuit
Fire alarm circuitFire alarm circuit
Fire alarm circuit
 
Unit 04 Protection of generators and transformers
Unit  04 Protection of generators and transformers Unit  04 Protection of generators and transformers
Unit 04 Protection of generators and transformers
 
Specification for electrical automation and instrumentation 02
Specification for electrical automation and instrumentation  02Specification for electrical automation and instrumentation  02
Specification for electrical automation and instrumentation 02
 
1352 linear bv
1352   linear bv1352   linear bv
1352 linear bv
 
1352 onf bv
1352   onf bv1352   onf bv
1352 onf bv
 
FTW31 - FTW32
FTW31 - FTW32FTW31 - FTW32
FTW31 - FTW32
 

Similar to Hxgn17 vacuum type ring main unit

Automatic voltage regulator(avr)
Automatic voltage regulator(avr)Automatic voltage regulator(avr)
Automatic voltage regulator(avr)JoeChueng
 
Automatic voltage regulator(avr)/voltage booster
Automatic voltage regulator(avr)/voltage boosterAutomatic voltage regulator(avr)/voltage booster
Automatic voltage regulator(avr)/voltage boosterJestem Zhou
 
Air insulated sf6 ring main unit 36kv
Air insulated sf6 ring main unit 36kvAir insulated sf6 ring main unit 36kv
Air insulated sf6 ring main unit 36kvAUTO RECLOSER
 
Air insulated sf6 ring main unit
Air insulated sf6 ring main unitAir insulated sf6 ring main unit
Air insulated sf6 ring main unitAUTO RECLOSER
 
Air insulated sf6 ring main unit
Air insulated sf6 ring main unitAir insulated sf6 ring main unit
Air insulated sf6 ring main unitJoeChueng
 
Kyn28 metal clad switchgear
Kyn28 metal clad switchgearKyn28 metal clad switchgear
Kyn28 metal clad switchgearJoeChueng
 
5T Intemediate Frequency Furnace
5T Intemediate Frequency Furnace5T Intemediate Frequency Furnace
5T Intemediate Frequency FurnaceGuo ke
 
GIS substation Information (Detailed Report)
GIS substation Information (Detailed Report)GIS substation Information (Detailed Report)
GIS substation Information (Detailed Report)siddharth sharma
 
Report on 220kv substation at Jassure
Report on 220kv substation at JassureReport on 220kv substation at Jassure
Report on 220kv substation at JassureShuvam Pathania
 
Dc Voltage Test System
Dc Voltage Test SystemDc Voltage Test System
Dc Voltage Test Systemkennypowerhv
 
Switchgear Equipment in a Substation
Switchgear Equipment in a SubstationSwitchgear Equipment in a Substation
Switchgear Equipment in a SubstationMd. Atiqur Rahman
 
Industrial Control Devices.pptx
Industrial Control Devices.pptxIndustrial Control Devices.pptx
Industrial Control Devices.pptxTALHARIAZ46
 
Ls catalog thiet bi dien tri mec_alts_catalog_e_0807_dienhathe.vn
Ls catalog thiet bi dien tri mec_alts_catalog_e_0807_dienhathe.vnLs catalog thiet bi dien tri mec_alts_catalog_e_0807_dienhathe.vn
Ls catalog thiet bi dien tri mec_alts_catalog_e_0807_dienhathe.vnDien Ha The
 

Similar to Hxgn17 vacuum type ring main unit (20)

Automatic voltage regulator(avr)
Automatic voltage regulator(avr)Automatic voltage regulator(avr)
Automatic voltage regulator(avr)
 
Automatic voltage regulator(avr)/voltage booster
Automatic voltage regulator(avr)/voltage boosterAutomatic voltage regulator(avr)/voltage booster
Automatic voltage regulator(avr)/voltage booster
 
Air insulated sf6 ring main unit 36kv
Air insulated sf6 ring main unit 36kvAir insulated sf6 ring main unit 36kv
Air insulated sf6 ring main unit 36kv
 
Air insulated sf6 ring main unit
Air insulated sf6 ring main unitAir insulated sf6 ring main unit
Air insulated sf6 ring main unit
 
Air insulated sf6 ring main unit
Air insulated sf6 ring main unitAir insulated sf6 ring main unit
Air insulated sf6 ring main unit
 
Kyn28 metal clad switchgear
Kyn28 metal clad switchgearKyn28 metal clad switchgear
Kyn28 metal clad switchgear
 
5T Intemediate Frequency Furnace
5T Intemediate Frequency Furnace5T Intemediate Frequency Furnace
5T Intemediate Frequency Furnace
 
Wapda Engineering Acadmy Report
Wapda Engineering Acadmy ReportWapda Engineering Acadmy Report
Wapda Engineering Acadmy Report
 
Summer Training presentation on 132/33 KV sub-station Minto park, Allahabad
Summer Training presentation on 132/33 KV sub-station Minto park, AllahabadSummer Training presentation on 132/33 KV sub-station Minto park, Allahabad
Summer Training presentation on 132/33 KV sub-station Minto park, Allahabad
 
GIS substation Information (Detailed Report)
GIS substation Information (Detailed Report)GIS substation Information (Detailed Report)
GIS substation Information (Detailed Report)
 
Report on 220kv substation at Jassure
Report on 220kv substation at JassureReport on 220kv substation at Jassure
Report on 220kv substation at Jassure
 
Dc Voltage Test System
Dc Voltage Test SystemDc Voltage Test System
Dc Voltage Test System
 
Kde200 user manual
Kde200 user manualKde200 user manual
Kde200 user manual
 
05 - Limit Switch - Fuji Electric
05 - Limit Switch - Fuji Electric05 - Limit Switch - Fuji Electric
05 - Limit Switch - Fuji Electric
 
Switchgear Equipment in a Substation
Switchgear Equipment in a SubstationSwitchgear Equipment in a Substation
Switchgear Equipment in a Substation
 
Thông số kĩ thuật siemens contactor 3 rt
Thông số kĩ thuật siemens contactor 3 rtThông số kĩ thuật siemens contactor 3 rt
Thông số kĩ thuật siemens contactor 3 rt
 
Industrial Control Devices.pptx
Industrial Control Devices.pptxIndustrial Control Devices.pptx
Industrial Control Devices.pptx
 
Ls catalog thiet bi dien tri mec_alts_catalog_e_0807_dienhathe.vn
Ls catalog thiet bi dien tri mec_alts_catalog_e_0807_dienhathe.vnLs catalog thiet bi dien tri mec_alts_catalog_e_0807_dienhathe.vn
Ls catalog thiet bi dien tri mec_alts_catalog_e_0807_dienhathe.vn
 
KYN28 12kV Medium voltage metal clad switchgear
KYN28 12kV Medium voltage metal clad switchgearKYN28 12kV Medium voltage metal clad switchgear
KYN28 12kV Medium voltage metal clad switchgear
 
LV switchgear FINAL.pptx
LV switchgear FINAL.pptxLV switchgear FINAL.pptx
LV switchgear FINAL.pptx
 

More from JoeChueng

Automatic reactive voltage regulator
Automatic reactive voltage regulatorAutomatic reactive voltage regulator
Automatic reactive voltage regulatorJoeChueng
 
Ys10 pad mounted transformer
Ys10 pad mounted transformerYs10 pad mounted transformer
Ys10 pad mounted transformerJoeChueng
 
Padmounted transformer
Padmounted transformerPadmounted transformer
Padmounted transformerJoeChueng
 
Prefabricated compact transformer
Prefabricated compact transformerPrefabricated compact transformer
Prefabricated compact transformerJoeChueng
 
VR-8 step voltage regulator
VR-8 step voltage regulatorVR-8 step voltage regulator
VR-8 step voltage regulatorJoeChueng
 
Dry type autotransformer
Dry type autotransformerDry type autotransformer
Dry type autotransformerJoeChueng
 
Cast resin dry type transformer
Cast resin dry type transformerCast resin dry type transformer
Cast resin dry type transformerJoeChueng
 
Oil immersed transformer
Oil immersed transformerOil immersed transformer
Oil immersed transformerJoeChueng
 
Neutral grounding resistors ngr
Neutral grounding resistors  ngrNeutral grounding resistors  ngr
Neutral grounding resistors ngrJoeChueng
 
Ltvr overhead line lt voltage regulator
Ltvr overhead line lt voltage regulatorLtvr overhead line lt voltage regulator
Ltvr overhead line lt voltage regulatorJoeChueng
 
Single phase pole mounted transformer
Single phase pole mounted transformerSingle phase pole mounted transformer
Single phase pole mounted transformerJoeChueng
 
D11 single phase overhead distribution transformer
D11 single phase overhead distribution transformerD11 single phase overhead distribution transformer
D11 single phase overhead distribution transformerJoeChueng
 
Fgw1 air break switch
Fgw1 air break switchFgw1 air break switch
Fgw1 air break switchJoeChueng
 
Jxf distribution box
Jxf distribution boxJxf distribution box
Jxf distribution boxJoeChueng
 
Xl21 distribution box
Xl21 distribution boxXl21 distribution box
Xl21 distribution boxJoeChueng
 
Power factor corrector
Power factor correctorPower factor corrector
Power factor correctorJoeChueng
 
Mns lv switchgear
Mns lv switchgearMns lv switchgear
Mns lv switchgearJoeChueng
 
Gcs lv switchgear draw out type
Gcs lv switchgear draw out typeGcs lv switchgear draw out type
Gcs lv switchgear draw out typeJoeChueng
 
Gck lv switchgear pt
Gck lv switchgear ptGck lv switchgear pt
Gck lv switchgear ptJoeChueng
 
Metal clad switchgear 33k v
Metal clad switchgear 33k v Metal clad switchgear 33k v
Metal clad switchgear 33k v JoeChueng
 

More from JoeChueng (20)

Automatic reactive voltage regulator
Automatic reactive voltage regulatorAutomatic reactive voltage regulator
Automatic reactive voltage regulator
 
Ys10 pad mounted transformer
Ys10 pad mounted transformerYs10 pad mounted transformer
Ys10 pad mounted transformer
 
Padmounted transformer
Padmounted transformerPadmounted transformer
Padmounted transformer
 
Prefabricated compact transformer
Prefabricated compact transformerPrefabricated compact transformer
Prefabricated compact transformer
 
VR-8 step voltage regulator
VR-8 step voltage regulatorVR-8 step voltage regulator
VR-8 step voltage regulator
 
Dry type autotransformer
Dry type autotransformerDry type autotransformer
Dry type autotransformer
 
Cast resin dry type transformer
Cast resin dry type transformerCast resin dry type transformer
Cast resin dry type transformer
 
Oil immersed transformer
Oil immersed transformerOil immersed transformer
Oil immersed transformer
 
Neutral grounding resistors ngr
Neutral grounding resistors  ngrNeutral grounding resistors  ngr
Neutral grounding resistors ngr
 
Ltvr overhead line lt voltage regulator
Ltvr overhead line lt voltage regulatorLtvr overhead line lt voltage regulator
Ltvr overhead line lt voltage regulator
 
Single phase pole mounted transformer
Single phase pole mounted transformerSingle phase pole mounted transformer
Single phase pole mounted transformer
 
D11 single phase overhead distribution transformer
D11 single phase overhead distribution transformerD11 single phase overhead distribution transformer
D11 single phase overhead distribution transformer
 
Fgw1 air break switch
Fgw1 air break switchFgw1 air break switch
Fgw1 air break switch
 
Jxf distribution box
Jxf distribution boxJxf distribution box
Jxf distribution box
 
Xl21 distribution box
Xl21 distribution boxXl21 distribution box
Xl21 distribution box
 
Power factor corrector
Power factor correctorPower factor corrector
Power factor corrector
 
Mns lv switchgear
Mns lv switchgearMns lv switchgear
Mns lv switchgear
 
Gcs lv switchgear draw out type
Gcs lv switchgear draw out typeGcs lv switchgear draw out type
Gcs lv switchgear draw out type
 
Gck lv switchgear pt
Gck lv switchgear ptGck lv switchgear pt
Gck lv switchgear pt
 
Metal clad switchgear 33k v
Metal clad switchgear 33k v Metal clad switchgear 33k v
Metal clad switchgear 33k v
 

Recently uploaded

Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxupamatechverse
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Christo Ananth
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escortsranjana rawat
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130Suhani Kapoor
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdfankushspencer015
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSKurinjimalarL3
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxpurnimasatapathy1234
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...Soham Mondal
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlysanyuktamishra911
 
Java Programming :Event Handling(Types of Events)
Java Programming :Event Handling(Types of Events)Java Programming :Event Handling(Types of Events)
Java Programming :Event Handling(Types of Events)simmis5
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxAsutosh Ranjan
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingrakeshbaidya232001
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)Suman Mia
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSRajkumarAkumalla
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 

Recently uploaded (20)

Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptx
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
 
Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdf
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
 
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINEDJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptx
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghly
 
Java Programming :Event Handling(Types of Events)
Java Programming :Event Handling(Types of Events)Java Programming :Event Handling(Types of Events)
Java Programming :Event Handling(Types of Events)
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
 
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
 

Hxgn17 vacuum type ring main unit

  • 1. Vacuum type ring main unit HXGN17 type 30/33/40.5KV Product brochure 2009/4 Zhejiang Farady Electric Co., Ltd. ISO9001&ISO14001 certificated enterprise
  • 2. ++++General, XGN17-40.5 box type fixed AC metal clad switchgear according to IEC62271-200 design. It can be used in three-phase AC rated frequency 50Hz single bus and single busbar with bypass system of indoor complete sets of equipment, as the acceptance and distribution of 35kV electric network with and has the circuit control, protection and monitoring the function. ++++Service environment 1 ambient air temperature limit: +40 C, lower limit: -10 C, the daily average temperature of not more than 35; 2 altitude is not more than 1000m; 3 the relative ambient temperature is not more than 95%, the average monthly is not more than 90%; 4 earthquake intensity is not more than 8; 5 the average value of water vapor pressure is not more than 2.2Kpa, the monthly average value is no more than 1.8kpa; 6 no fire, explosion hazards, serious pollution, chemical corrosion and violent place of this building. Special working conditions In the case of more than the normal use of the environment under the conditions, by the user and the manufacturer. ++++Feature XGN17-40.5 box type fixed AC metal clad switchgear device is fixed arranged composite structure and its basic skeleton steel and steel plate bending parts by welding and, the cabinet body shell is IP2X level of protection. Mainly by the cabinet and the cabinet after assembly and made the switch equipment, uses a different set corresponding to a functional unit, cabinet between the charged body were to air main insulation and the charged body between and the relative between the insulation distance of not less than 300mm. 1) before the cabinet: before the cabinet set up main busbar and busbar disconnector chamber, a circuit breaker chamber, relay room, main busbar and busbar disconnector chamber at the top of the cabinet, the circuit breaker room arranged at the bottom of the cabinet, the chamber is also provided with a current mutual inductor, two rooms have insulation plates separated. Through the bus bar casing connected. Relay settings in the cabinet is the front of the middle, small bus terminal 15 day, and a second cable channel, terminal room located in the left door, can install JH10 terminals more than 80, at the bottom of the chamber is also provided M12 connection bolt for auxiliary circuit connected to use, right door for dimensional repair channel. The upper part of the terminal chamber is an operating panel, and can be provided with an auxiliary switch. 2) after the cabinet: after the cabinet bolts with a cabinet is connected, the cabinet according to need can be set to bypass bus and isolating switch, an overhead pass in and out line from the cabinet by, set the bypass bus, overhead line and the reach the safe height, need to add a small attached or obscuration network. When the
  • 3. mother is not set, the overhead outlet can be passed from the top of the back cabinet. The cabinet can also be installed with a voltage transformer or a lightning arrester, and the contact bus and the cable outlet are installed in the cabinet. The back door bolt is fixed, if the charged display prompt no electricity, can open the back door, the main bus room and after the cabinet are separated by a baffle plate ++++ Main technical specifications No Item Unit Data 1 Rated voltage kV 30/33/40.5 2 Rated current Hz 50/60 3 Rated insulation level lightning impulse voltage kV 185 Power frequency impulse voltage kV 95 4 Rated current A 630/1250/16 00/2000 5 Rated thermal stability current KA/4 S 31.5 6 Rated dynamic stability current kA 63 7 Rated short circuit breaking current kA 25 8 Rated short circuit current (KA) kA 63 9 Rated voltage, switch and auxiliary circuit V DC 24, 36, 48,110,220 10 protection class IP2X ++++structure HXGN17 series metal clad switchgear usef high voltage vacuum load switch and fuse combination vacuum load switch for incoming and outgoing protectiot, which is suitable for the three phase AC 50HZ,uo to 40.5kV power system, or with sets of power distribution equipment and ring main unit switch cabinet, combined AC power plants and other supporting the use, widely used in wind power generation, city network construction and transformation project, industrial and mining enterprises, high-rise buildings and public facilities can be as a ring network power supply unit or terminal equipment, power distribution, control and protection. The technical performance of the product is in line with the IEC62271-100 The product has the advantages of high breaking capacity, safety and reliability, long service life, frequent operation, compact structure, small volume, light weight, no need of maintenance and the like. With breaking rated current, overload current, short circuit current and prevent defect running of the equipment, the switch has obvious isolating fracture loading with the closing capacity ground off and electric spring mechanism, remote remote control capability
  • 4. ++++Use condition 3.1 ambient air temperature does not exceed 40 degrees, and the average 24h measured and does not exceed 35 degrees, low ambient air temperature of -25; 3.2 the effect of sun radiation can be ignored; 3.3 altitude is not more than 1000m; 3.4 ambient air is not significantly contaminated by dust, smoke, corrosion, corrosion, or flammable gas, steam or salt mist; 3.5 relative humidity, average plant does not exceed 95%; the vapor pressure of water on average less than 22kPa; lunar humidity on average no more than 90%; The average monthly water vapor pressure is not more than 1.8KPa; 3.6 from the switchgear and control equipment of external vibration or earthquake can be ignored; 3.7 the magnitude of the electromagnetic interference in the two system is not more than 1.6kV. ++++ Technical parameters 4.1 main technical parameters of combined electric appliance Technical parameters of vacuum load switch assembly and adjustment in 4.2 combined electric appliance 4.3 the technical parameters of the assembly and adjustment of the isolating switch assembled by the combined electric appliance 4.4 the technical parameters of the assembly and adjustment of the grounding switch of the combined electric appliance 4.5 the technical parameters of fuse fuse 5 structure and working principle ++++ Structure Combination of electrical appliances for triode linked structure: mainly composed of a frame, a vacuum interrupter, isolating switch with fuse), grounding switch and a spring operating mechanism, isolating switch and vacuum arc arc and earthing switch through the insulator is fixed on the frame and spring operating moving mechanism is arranged in the frame on the side panel. ++++ Working Principle Operation of 5.2.1 vacuum arc extinguishing chamber Vacuum switchgear destroy the mode of operation of the arc chamber using electric spring operation mechanism for closing, with tripping electromagnet of gate, for manual closing. The opening operation, manual closing operating handle clockwise spring operating mechanism transmission shaft. 5.2.2 isolation switch, grounding switch, closing operation A reliable mechanical interlocking device is arranged between the three electric appliances of the vacuum arc extinguishing chamber, the isolating switch and the grounding switch, and the isolating switch and the grounding switch are operated by the same shaft. When the switch closed, after the vacuum load switch. On the contrary, when the vacuum load switch is in the state of switch, the switch and the grounding switch can be operated. 5.2.3 fuse impact release switch In the closing position of the combined electric and when the short circuit current and overload current flows in the main circuit, at least one phase fuse fuse. Impactor action, brake speed depending on the size of current, current
  • 5. divided brake speed faster, action of mechanical tripping device of the combined electrical equipment, so that the vacuum arc extinguishing chamber in a tripping spring achieve fast and reliable brake.
  • 6. ++++Before order pls clarify of your requirement with our tech Copyright 2014 Farady Electric Zhejiang Farady Electric Co.,Ltd TEL:0086-577-61722510/61777258 Fax:0086-577-61777257 Http://www.farady-electric.com Email:info@farady.cn Add:Su’ao,Liushi,Yueqing,Zhejiang,P.R.China, 325604