This chapter tells about the approximate length and capacity of the west and east extension branches of the flat primary canal 1. This is basically for teaching purpose to the teams who involve in doing the micro survey of the different segments of fpc. The exact length and the capacity will be determined only after the level of the canal, size of the canal, length of the canal values obtained by the micro survey by the respective teams.
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
S5c16 chapter 16-flat primary canal (fpc1) we & ee lengths.
1. Contentsof Section5: Reticularcanal system forInterlinkingIndianRivers.
Chapter16-Flat Primarycanal (FPC1) WE & EE Lengths.
16.1-FPC1 WE Lengthsandapproximate capacity.
16.2-FPC1 EE Lengthsand approximate capacity.
Chapter 16: Flat Primary canal (FPC1) WE &
EE Lengths:
16.1. FPC1 WE Lengths and approximate capacity:
FPC1WE Lengths, total length and the approximate capacity are as follows:
SN. Description.
[Length in kms]
1.FPC1WEStart to FPC1WE Luni 500.
[278.21]
2.FPC1WE Luni to FPC1WE Bandi 500.
[176.56]
3.FPC1WE Bandi to FPC1WE Sucri 500
2. [80.32]
4.FPC1WE Sucri to FPC1WE Jawai 500.
[114.24]
5.FPC1WE Jawai to FPC1WE Sabarmathi 500.
[148.19]
6.FPC1WE Sabarmathi to FPC1WE Som 500.
[229.55]
3. 7.FPC1WE Som to FPC1WE End 500.
[83.74]
Total FPC1 WE CRL Length in Kms is
[1110.81]
Total canal length we are going to save with CE, RE, DCC, BD in Kms.
[145.49]
Total length of the CE, RE, DCC, BD put together in Kms
[2.54]
The Length (Actual) of the probable FPC1WE in Kms.
[967.86]
The capacity (Volume) of storable water (with the canal width of 200 mts, depth of 25 mts, but the
maximum level maintained will be 20 mts) in the FPC1WE (3871.44 million cubic meters) in TMC.
(This volume can be filled and discharged any number of times.)
142.93 TMC
4. 16.2. FPC1 EE Lengths and approximate capacity:
FPC1EE Lengths, total length and the approximate capacity :
SN.Description.
[Lengthinkms]
1.FPC1EE Heran to FPC1EE Mahanadhi 500.
[106.74]
2.FPC1EE Mahanadhi toFPC1EE Son500.
[274.90]
3.FPC1EE Son to FPC1EE Hasdo 500.
[63.19]
There isan elevatedareabetweenFPC1EESonto FPC1EE Hasdo 500 path and the maximumlevel
we get inthispath is524 mtsAMSL at (230
05’2.40”N) (820
01’50.03”E). DCC isrequired.
5. 4.FPC1EE Hasdo to FPC1EE Mand 500.
[266.49]
5.FPC1EE Mand to FPC1EE Lb 500.
[75.36]
6.FPC1EE Lb to FPC1EE Sankh500.
[168.50]
6. 7.FPC1EE Sankh to FPC1EE SouthKoel 500.
[147.26]
8.FPC1EE South koel toFPC1EE Subarnarekha500.
[207.47]
9.FPC1EE Subarnarekhato FPC1EE Damodhar500.
[166.82]
7. 10.FPC1EE Damodharto FPC1EE Rihand500.
[594.64]
11.FPC1EE Rihandto FPC1EE HasdoMand path500.
[55.70]
There isan elevatedareabetweenFPC1EERihandtoFPC1EE Hasdo Mand path 500 pathand the
maximumlevelwe getinthispathis562 mts AMSL at (230
014’8.85”N) (820
039’37.29”E). DCC is
required.
The FPC1EE whichoriginatesfromRihand500 will Jointhe HasdoMand pathof canal at the point
(230
010’52.99”N) (820
037’26.56”E) encirclingthe HazaribaghRange of hills.
FPC1 EE SB 500 starts at the FPC1EE Sonto Hasdo canal pathat the point(230
05’25.60”N)
(820
08’30.06”E).
8. 12.FPC1EE SB Start to FPC1EE SB Seonath500.
[553.78]
LowestpointbetweenFPC1EESB Start to FPC1EE SB Seonath500 path is366mts AMSL at
(200
055’3.52”N) (800
034’8.53”E). We have to do BD or U tube to bypass thisdepression.
13.FPC1EE SB SeonathtoFPC1EE SB Mahanadhi 500.
[171.54]
LowestpointbetweenFPC1EESB SeonathtoFPC1EE SB Mahanadhi 500 path is403mts AMSL at
(200
023’21.93”N) (810
05’50.98”E).
We have to doBD or U tube to bypass thisdepression.
9. 14.FPC1EE SB Mahanadhi to FPC1EE SB Tel500.
[94.09]
There isan elevatedareabetweenFPC1EESBMahanadhi toFPC1EE SB Tel500 path and the
maximumlevelwe getinthispathis564 mts AMSL at (200
05’0.87”N) (820
012’35.49”E). DCC is
required.
15.FPC1EE SB Tel to FPC1EE SB Sabari 500.
[981.82]
16.FPC1EE SB Sabari to FPC1EE SB Indravathi 500.
[237.99]
10. Total FPC1WE CRL Lengthin Kmsis
[4166.29]
Total canal lengthwe are goingto save withCE, RE, DCC, BD inKms.
[292.43]
Total lengthof the CE,RE, DCC,BD puttogetherinKms
[15.21]
The Length (Actual) of the probable FPC1EEinKms.
[3889.07]
The capacity (Volume)of storable water(withthe canal widthof 200 mts,depthof 25 mts,but the
maximumlevelmaintainedwillbe 20 mts) inthe FPC1WE (15556.28 millioncubicmeters) inTMC.
(Thisvolume canbe filledanddischargedanynumberof times.)
574.33 TMC.