SCHOOL OF ARCHITECTURE, BUILDING & DESIGN
Centre for Modern Architecture Studies in Southeast Asia
Master of Architecture
ENVIRONMENT AND TECHNOLOGY II (ARC71003)
Project 2 : Service Core Optimal Proposal (Individual)
Student Name: Heng Sy Hua
Student ID: 0321999
CONTENT
1.0 INTRODUCTION
2.0 SITE INTRODUCTION
3.0 SITE ANALYSIS
3.1 Sun path and shadow analysis
3.2 Temperature and Humidity
3.3 Wind Flow
4.0 BUILDING INTRODUCTION
4.1 Building Information
4.2 Purpose Group
4.3 Occupancy Load
5.0 PASSIVE FIRE PROTECTION
5.1 Fire Appliance Access
5.2 Hydrant Location
5.3 Means of Escape
6.0 ACTIVE FIRE PROTECTION
6.1 Lift and Service Core
7.0 REFERENCE
1.0 INTRODUCTION
This module emphasizes the role of building technology and sustainability in building
design by analyzing and evaluating complex buildings or a group of buildings. It regards
architecture as the integration of environment, technology and architecture. These three
factors are considered to be an indispensable part of architectural design and can be
rigorously evaluated through theory.
The objectives of the project are as follows:
• Introduce standards and regulations for building core design.
• Use technology as a functional element or function of architectural design.
• Integrate technical and environmental factors to improve building efficiency and
practicability.
2.0 SITE INTRODUCTION
Figure 1: Location of Proposed site.
Klang, the official royal town of Klang Klang is a royal town and the former capital of
Selangor, Malaysia. Before the rise of Kuala Lumpur, it was the private capital of
Selangor, and now the capital is Shah Alam.
The city currently includes a population of 240,000 in Klang and 12,000 in the city
center. Klang is divided into two main parts, namely North Klang and South Klang. Our
site is located in North Klang.
Similar to the south side, the north side of Klang has a large number of commercial and
religious areas. However, North Kland, like many other cities in Malaysia, is slowly
suffering from the decline of the city. There is not much future development and social
participation here. Therefore, the identity of North Klang has not yet been reflected.
There are few issues identifies on site, which are :
3.0 SITE ANALYSIS
Sun Path and shadow analysis
Figure 3: Sunpath on site.
Figure 4: Shadow analysis of three different times of the year
The site is surrounded by mid-rise buildings. The site is just slightly shaded in the
morning from the morning sun. The site is fully exposed to afternoon sun at 12pm. On
the other hand, the site is almost fully shaded by the building located beside the site.
Therefore, the sun-shading of the building should focus on the morning sun from the
east and afternoon sun.
Temperature and Humidity
Figure 5: Average annual temperature of Klang
According to the date reading from the previous 12 months, the average annual
temperature of Klang is 27​°C. The minimum is 23°C while the maximum temperature is 
33°C. 
Figure 6: Average annual humidity in Klang
The average annual humidity of Klang is 75% ​. The minimum humidity is 70% while the 
maximum humidity goes up to 80%.  
 
Klang has a tropical hot and humid climate. Therefore, the building design aims to
minimise direct heat gain from sun and maximise natural ventilation. Besides, the
building also aims to achieve thermal comfort, ranging from 20​°C to 22°C according to 
the psychrometric chart. Therefore, the choice of materials and configuration of forms 
are carefully chosen and designed to achieve better thermal comfort for the users.  
Wind Flow
Figure 7: Prevailing Wind direction on site.
On average, the dominant wind direction at Klang, is blowing from south-southeast and
northeast.
Figure 8: Annual average wind speed
Figure 9: Wind flow diagram on site.
The average wind speed is at 3m/s throughout the year except for November which has
wind up to 2m/s. Highest wind blow is from the south side of the site with 2.15m/s
4.0 BUILDING INTRODUCTION
4.1 Building information
Figure 10 : Perspective view or Klang CivIc Center
The Urban Design Studio embarks on a proposal for a civic center situated at North
Klang. The Klang Civic center is inspired by Galeri of Sultan Abdul Aziz in South Klang
which is the informal tourist center for the tourist. The Klang Civic Center aims not only
to be a civic center that serves the local community, but also a tourist center that
welcomes tourists. By having an intention to serve these two main users groups, the
civic center will be a place where the tourists meet the locals.
The proposed Klang Civic Center is a 4-storey high with one underground car park
basement. The gross floor area of the building is approximately 5,000 square meter.
The ground floor is a public space that opened up to the public. There are tourist
information centers, bazaars, markets, green spaces and courtyards. The others levels
concentrated on semi-open and private usage.There are, workshops, studios, gallery,
library, administration offices and seminars rooms.
Disposal
TNB
Firecontrol
gensett
MSB
Shop
tuorist center
locker room
WC
Shop
UP
1
3
6
8
10
12
14
16
18
DN
UP
1
3
6
8
10
12
14
16
18
DN
UPDN
UP
12345
6
A
B
C
D
lift lobby
WC
Shop
Shop
GROUND FLOOR PLAN
1:350
PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
12345
6
A
B
C
D
UPDN
UPDN
UP
DN
18
16
14
12
10
8
6
3
1
UP
UP
1
3
6
8
10
12
14
16
18
DN
studio 2
studio 1
meeting room office
Workshop
Workshop
WC
WCWC
1235
6
Workshop
FIRST FLOOR PLAN
1:350
PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
Workshop
Seminar room 1
Private office
Shop
Shop
Shop
Bridge to carpark
Seminar room 2
Manager office
Manager office
file room
store room
UP
1
3
6
8
10
12
14
16
18
DN
UPDN
UPDN
UP
1
3
6
8
10
12
14
16
18
DN
pantry
UP
DN
WC WC
WC
Workshop
Object
library
Family room
12345
6
A
B
C
D
2ND FLOOR PLAN
1:350
PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
Exhibition Space
store
event
space
Librarian
office
discussion
Audio
room
UPDN
UPDN
Workshop
UP
UP
1
3
6
8
10
12
14
16
18
DN
UP
1
3
6
8
10
12
14
16
18
DN
12345
6
A
B
C
D
library
DN
WC WC
WC
1235
6
3RD FLOOR PLAN
1:350
PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
Roof
top cafe
UPDN
DN
UP
1
3
6
8
10
12
14
16
18
DN
UP
1
3
6
8
10
12
14
16
18
DN
12345
6
A
B
C
D
HERBS GARDEN
outdoor playground
bbq area
souvenier shop
4TH FLOOR PLAN
1:350
PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
4.2 Purpose Group
Based on Selangor Uniform Building By-Laws 1986 Fifth Schedule, the Klang Civic
Center are under Institutional and Shop purpose groups.
Table 1: Designated for purpose groups according to Fifth Schedule
By Law Clause 134: Designation of purpose group
For the purpose of this Part every building or compartment shall be regarded according
to its use or intended use as falling within one of the purpose groups set out in the Fifth
Schedule to these By-laws and, where a building is divided into compartments, used or
intended to .be used for different purposes, the purpose group of each compartment
shall be determined separately:
Provided that where the whole or part of a building or compartment, as the case may
be, is used or intended to be used for more than one purpose, only the main purpose of
use of that building or compartment shall be taken into account in determining into
which purpose group it falls.
By Law Clause 138: Designation of purpose group
The following walls and floors in buildings shall be constructed as compartment walls or
compartment floors:
(a) any floor m a building of Purpose Group 2 (Institutional)
(b) any wall or floor separating a flat or maisonette from any other part of ·the same
building;
(c) any wall or floor separating part of a building from any other part of the same
building which is used or intended to be used mainly for a purpose falling within a
different purpose group as set out in the Fifth Schedule to these By-laws; and
(d) any floor immediately over a basement storey if such basement storey has an area
exceeding 100 square metres.
4.3 Occupancy Load
The occupancy load and capacity exits are based on the following By-Laws:
By Law Clause 175: Calculation of occupant load.
Calculation of occupancy loads and capacity of exits shall be in accordance with
provisions of the Seventh Schedule to these By-Laws.
Based on Selangor Uniform Building By-Laws 1986 Seventh Schedule, the calculation
of occupancy load and capacity of exits for shops purpose group are as follow:
Table 2: Capacity Exits of each purpose Group are stated.
By Law Clause 167: Horizontal Exits
(1) Except as provided for in by-law 194 every compartment shall be provided with at
least two storey exits located as far as practical from each other and in no case closer
than 4.5 metres and in such position that the travel distances specified in the Seventh
Schedule to these By-laws are not exceeded.
(2) The width of storey exits shall be in accordance with the provisions in the Seventh
Schedule to these By-laws.
By Law Clause 168: Staircases
(1) Except as provided for in by-law 194 every upper floor shall have means of egress
via at least two separate staircases.
(2) Staircases shall be of such width that in the event of any one staircase not being
available for escape purposes the remaining staircases shall accommodate the highest
occupancy load of any one floor discharging into it ,calculated in accordance with
provisions in the Seventh schedule to these By-laws.
(3) The required width of a staircase shall be the clear width between walls but
handrails may be permitted to encroach on this width to a maximum of 75 millimetres.
(4) The required width of a staircase shall be maintained throughout its length including
at landings.
(5) Doors giving access to staircases shall be so positioned that their swing shall at no
point encroach on the required width of the staircase or landing.
By Law Clause 169: Exit Route
No exit route may reduce in width along its path of travel from the storey exit to the final
exit.
By Law Clause 170: Egress through unenclosed openings
Where unenclosed openings are permitted between floors and for a mezzanine floor,
egress may be by way of an open staircase to an adjacent floor and thence to a story
exit:
(a) the layout is such that a fire originating anywhere within the compartment will be.
obvious to the occupants of all communicating levels or areas;
(b) the travel distances specified in the Seventh Schedule to these By-laws are not
exceeded;
(c) only 50% of the occupants of a floor are assumed to use the open staircase and
storey exits are provided at every level to accommodate the other 50% of the occupants
of that level in accordance with the provisions of the Seventh Schedule to these
by-laws; and
(d) the storey exits on the principal floor through which other levels discharge are
designed to handle the occupant; of that floor plus 50% .of the occupants from the
adjacent levels discharging through it.
By Law Clause 171: Horizontal Exits
(1) Where appropriate, horizontal exits may be provided in lieu of other exits.
(2) Where horizontal exits are provided protected staircases and final exits need only be
of a width to accommodate the occupancy load of the larger compartment or building
discharging into it so long as the total number of exit widths provided is not reduced to
less than half that would otherwise be required for the whole building.
(3) For institutional occupancies the total exit capacity other than horizontal exits shall
not be reduced by more than one-third that would otherwise be required for the entire
area of the building.
5.0 PASSIVE FIRE PROTECTION
5.1 Perimeter Appliances Access
The fire appliances access is based on the following By Laws from Selangor Uniform
Building By-Laws 1986:
By Law Clause 140: Fire Appliance access
All buildings in excess of 7000 cubic metres shall abut upon a street or road or open
space of not less than 12 metres width and accessible to fire brigade appliances. The
proportion of the building abutting the street, road or open space shall be in accordance
with the following scale:
Table 3 : Building volume and required proportion of perimeter access
The volume of Klang Civic Center is approximately ​31,910 cubic meter​. Therefore, it is
under the range of 28,000 to 56,000 cubic meter. Therefore, at least ​one forth​ of the
perimeter of the building need be abutting the street, road or open space.
The perimeter of the building is​ 247m. ​Thus, at least ​61.75m perimeter of the buil​ding
needs to be abutting a road or open space of not less than 12 metres width and
accessible to fire brigade appliances.
5.2 Hydrant Location
By Law Clause 225: Detecting and extinguishing fire
(1) Every building shall be provided with means of detecting extinguishing fire. and
extinguishing fire and with fire alarms together with illuminated exit signs in accordance
with the requirements as specified in the Tenth Schedule to these By-laws.
(2) Every building shall be served by at least one fire hydrant located not more than
91.5 metres from the nearest point of fire brigade access.
(3) Depending on the size and location of the building and the provision of access for
fire appliances, additional fire hydrants shall be provided as may be required by the Fire
Authority.
There is an existing fire hydrant placed beside the site. Therefore, 2 new fire hydrants
with a 45m radius are added on site to achieve full coverage of the building. The
hydrant proposed is located not less than 2m from the Klang Civic Center and between
0.61m to 2.4m from the fire appliances access.
Disposal
TNB
Firecontrol
gensett
MSB
Shop
tuorist center
locker room
WC
Shop
UP
1
3
6
8
10
12
14
16
18
DN
UP
1
3
6
8
10
12
14
16
18
DN
UPDN
UPDN
12345
6
A
B
C
D
lift lobby
WC
Shop
Shop
H
H
SITE PLAN
1:500
PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
5.3 Means of Escape
According to Uniform Building By-laws 1984 Seventh Schedule, as this project falls
under the purpose ground of Institutional and Shops, the maximum travel distances for
sprinkled design is 45m while the dead end limit is 15m.
Table 4: Maximum running distances
Besides, the travel distance are calculated based on following by-laws:
By Law Clause 165 : Measurement of travel distance to exist.
(1) The travel distance to an exit shall be measured on the floor or other walking surface
along the centre line of the natural path of travel, starting 0.300 metre from the most
remote point of occupancy, curving around any comers or obstructions with 0.300 metre
clearance therefrom and ending at the storey exit. Where measurement includes stairs,
it shall be taken in the plane of the
trend noising.
(2) In the case of open areas the distance to exits shall be measured from the most
remote point of occupancy provided that the direct distance shall not exceed two-thirds
the permitted travel distance.
(3} In the case of "individual rooms which are subject to occupancy of not more than six
persons, the travel distance shall be measured from the doors of such rooms: Provided
that the travel distance from any point in the room to the room door does not exceed 15
metres.
(4) The maximum travel distances to exits and dead end limits shall be as specified in
the Seventh Schedule of theSe By-laws.
By-law Clause 166: Exits to be accessible at all times.
1) Except as permitted by by-law 167 not less than two separate exits shall be provided
from each storey together with such additional exits as may be necessary
2) The exits shall be sited and the exit access shall be so arranged that the exits are
within the limits of travel distance as specified in the Seventh Schedule to these By-laws
and are readily accessible at all times.
By-law Clause 167: Storey exits.
1) Except as provided for in by-law 194 every compartment shall be provided with at
least two storey exits located as far as practical from each other and in no case closer
than 4.5 metres and in such position that the travel distances specified in the Seventh
Schedule to these By-laws are not exceeded.
2) The width of storey exits shall be in accordance with the provisions the Seventh
Schedule to these By-laws.
By-law Clause 170: Egress through unenclosed openings.
Where unenclosed openings are permitted between floors and for a mezzanine floor,
egress may be by way of an open staircase to an adjacent floor and thence to a story
exit:
b) The travel distances specified in the Seventh Schedule to these By-laws are not
exceeded.
The ground floor of Klang Civic Center is naturally ventilated with an open plan.
Therefore, users can safely exits the building in ground floor. Thus, no travel distance
are measured.
12345
6
A
B
C
D
UPDN
UPDN
UP
DN
18
16
14
12
10
8
6
3
1
UP
UP
1
3
6
8
10
12
14
16
18
DN
studio 2
studio 1
meeting room office
Workshop
Workshop
WC
WCWC
1235
6
43285mm
34360mm
30412mm
37452mm
Workshop
FIRST FLOOR PLAN
1:350
PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
Workshop
Seminar room 1
Private office
Shop
Shop
Shop
Bridge to carpark
Seminar room 2
Manager office
Manager office
file room
store room
UP
1
3
6
8
10
12
14
16
18
DN
UPDN
UPDN
UP
1
3
6
8
10
12
14
16
18
DN
pantry
UP
DN
WC WC
WC
Workshop
Object
library
Family room
12345
6
A
B
C
D
44368mm
34800m
m
40182mm
33803mm
2ND FLOOR PLAN
1:350
PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
Exhibition Space
store
event
space
Librarian
office
discussion
Audio
room
UPDN
UPDN
Workshop
UP
UP
1
3
6
8
10
12
14
16
18
DN
UP
1
3
6
8
10
12
14
16
18
DN
12345
6
A
B
C
D
library
DN
WC WC
WC
1235
6
43721mm
27297mm
32860mm
30983mm
3RD FLOOR PLAN
1:350
PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
Roof
top cafe
UPDN
DN
UP
1
3
6
8
10
12
14
16
18
DN
UP
1
3
6
8
10
12
14
16
18
DN
12345
6
A
B
C
D
HERBS GARDEN
outdoor playground
bbq area
souvenier shop
33803mm
29850mm
15835mm
4TH FLOOR PLAN
1:350
PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
PRODUCEDBYANAUTODESKSTUDENTVERSION
5.4 Escape Provision Computation
The escape provision of the building is based on following by-laws :
By Law Clause 175 : Calculation of occupant load
Calculation of occupancy loads and capacity of exits shall be in accordance with the
provisions of the Seventh Schedule to these By-laws.
By Law Clause 176 : Computing storey exit widths
To compute the required exit width from individual floors of a building-
(a) calculate the floor area net or gross whichever is applicable;
(b) determine the allowable occupancy load factor from Table;
(c) divide the floor area by the number of square metre per person to determine the
number of persons for which exits must be provided for that floor;
(d) determine from the table the capacity of the type of exit to be used for the purpose
group being designed; and
(e) calculate the number of units of exit width for each type of exit used based upon the
capacity.
By Law Clause 177 : Computing number of staircases and staircase widths.
The following factors shall be used in computing the exit computing widths:
(a) in a multi-storeyed building if x units of exit width are required from each floor the
staircases serving those floors do not need to be x times the number of floors
served in units of exit width. The staircases need be only wide enough to serve each
floor but not less than the minimum width allowed and in every case one of the
protected staircases shall be assumed to be inaccessible and the remaining protected
staircase shall be of sufficient width and number to accommodate the relevant
occupancy;
(b) depending on the occupancy, street floor exits have to be sized to handle not only
the occupant load of the street floor but also a percentage of the load of the exits
discharging to the street floor from floors above and below;
(c) exits should never decrease in width along their length of travel and, if two or more
exits converge into a commonexit, the common exit should never·be narrower than the
sum of the width of the exits converging into it;
·(f) there should be no decrease in width along the path of travel of a staircase.
6.0 ACTIVE FIRE PROTECTION
According to the Uniform Building By-laws 1984 Seventh Schedule, the numbers and
width of staircase design for Klang Civic Center which falls under Institutional and Shop
purpose groups are calculated in Table 5:
FLOOR LEVEL PURPOSE GROUP
(Based on Fifth Schedule)
PROPOSED SPACE
Ground Floor Shops (V) Shops
First Floor Institutional (II) Workshop, Studio
Second Floor Institutional (II) Library, Workshop,
Seminar Room, Office
Third Floor Institutional (II) Exhibition Space,
Workshop, Event Space,
Library
Forth Floor Shops (V) Souvenir Shop, Roof Top
cafe
Table 5 :Purpose Group of each floor based on UBBL Fifth Schedule
Purpose
Group
Shop (V) Institutional
(II)
Institutional
(II)
Institutional
(II)
Shop (V)
Occupancy
Load
3 2 2 2 6
Floor Area
(m2)
1679 1182 1154 1160 1078
Occupancy
(C/B)
1697/3 =
560
1182 / 2 =
591
1154 / 2 =
557
1160 / 2 =
580
1078/6= 180
Exit
Capacity
Required
560 / 100 =
5.6
591 / 100 =
5.91
557 / 100 =
5.57
580 / 100 =
5.8
180 / 100 =
1.80
Minimum
Exit Width
(E x
550mm)
3,080mm 3,245mm 3,063.5mm 3,190mm 990mm
Table 6 : Minimum Exit Width of each floor are calculated.
Ground floor
Main staircase (Protected) 1250mm
Secondary staircase 1 1250mm
Secondary staircase 2 2000mm
Secondary staircase 3 68867mm
Total Width 73267mm
Assuming the main
staircase of the ground
floor (1,200mm) is
inaccessible, the
remaining exit width
(73267mm – 1,200mm)
is 72,067mm > 3,080mm,
and therefore the
provision satisfies the
By-laws.
First floor
Main staircase (Protected) 1250mm
Secondary staircase 1 1250mm
Secondary staircase 2 2000mm
Total Width 4500mm
Assuming the main
staircase of the ground
floor (1,250mm) is
inaccessible, the
remaining exit width
(4500mm – 1,200mm) is
3300mm > 3,245mm,
and therefore the
provision satisfies the
By-laws.
Second floor
Main staircase (Protected) 1250mm
Secondary staircase 1 1250mm
Secondary staircase 2 2000mm
Total Width 4500mm
Assuming the main
staircase of the ground
floor (1,250mm) is
inaccessible, the
remaining exit width
(4500mm – 1,200mm) is
3300mm > 3,063.5mm,
and therefore the
provision satisfies the
By-laws.
Third floor
Main staircase (Protected) 1250mm
Secondary staircase 1 1250mm
Secondary staircase 2 2000mm
Total Width 4500mm
Assuming the main
staircase of the ground
floor (1,250mm) is
inaccessible, the
remaining exit width
(4500mm – 1,200mm) is
3300mm > 3,190mm,
and therefore the
provision satisfies the
By-laws.
Forth floor
Main staircase (Protected) 1250mm
Secondary staircase 1 1250mm
Secondary staircase 2 2000mm
Total Width 4500mm
Assuming the main
staircase of the ground
floor (1,250mm) is
inaccessible, the
remaining exit width
(4500mm – 1,200mm) is
3300mm > 990mm, and
therefore the provision
satisfies the By-laws.
6.0 ACTIVE FIRE PROTECTION
6.1 Lift and Service Core
Both main lifts are accessible from the open and natural ventilated corridor at every
floor. Service lift are only accessible inside the protected lift lobby.
Figure 11 : Ground Floor Plan Drawing indicating location of lift core
The provision of lift lobby is based on follow Building By-Laws :
By Law Clause 152 : Openings in Lift Shafts.
(1) Every opening in a lift shaft or lift entrance shall open into a protected lobby unless
other suitable means of protection lift to the opening to the satisfaction of the local
authority is provided. These requirements shall not apply to open type industrial and
other special buildings as may be approved by the D.G.F.S.
(3) No glass shall be used for in landing doors except for vision in which case any vision
panel shall or be glazed with wired safety glass, and shall not be more than 0.0161
square metre and the total area of one of more vision panels in any landing door shall
be not more than 0.0156 square metre.
By Law Clause 153 : Smoke Detector in lift lobbies.
(1) All lift lobbies shall be provided with smoke detectors.
(2) Liff not opening into a smoke lobby shall not use door reopening devices controlled
by light beam or photo-detectors unless incorporated with a force close feature which
after thirty seconds of any interruption of the beam causes the door to close within a
preset time.
By Law Clause 157 : Protected shafts consisting of staircase.
A protected staircase or a protected shaft containing a staircase, shall not contain any
pipe conveying gas or oil or any ventilation duct other tlian a duct serving only that
staircase or shaft.
Fire Extinguishing and Alarm System
Klang Civic Center is under Institutional and shops group. Therefore, based on
Selangor Uniform Building By-laws 1986 Tenth Schedule, the proposed Klang Civic
Center requires followings elements:
1. Fire detection
2. Fire alarm
3. Extinguishing system
Table 7: above show the requirement for fire extinguisher and alarm system
The requirement of fire extinguishing and alarm systems are based on following
By-Laws:
By Law Clause 225 : Detecting and extinguishing fire.
(2) Every building shall be provided with means of detecting and extinguishing fire and
with fire alarms together with illuminated exit signs in accordance with requirements as
specified in the Tenth Schedule to these By-Laws.
By Law Clause 237 : Fire alarm
(1) Fire alarm shall be provided in accordance with Tenth schedule to these By Laws.
Therefore, Klang Civic Center need to incorporates different systems to achieve
optimum fire safety, which includes:
1. Automatic Sprinkler System
2. Hose Reel System
3. Automatic Fire Detector System
4. Manual Electric Fire Alarm System
Figure 12 : Detail drawing of Lift core
7.0 REFERENCE
1. Laws of Malaysia. (1986). Selangor uniform building by-laws 1986. Kuala
Lumpur: MDC Publishers Sdn. Bhd.
2. Laws of Malaysia. (1984). Uniform building by-laws 1984. Kuala Lumpur:
International Law Book Services.
3. Hamzah, A. B. (2006). Guide to fire protection in Malaysia. Kuala Lumpur: The
Institute of Fire Engineers (UK) Malaysia Branch.

More Related Content

Similar to Final ent full report

Building Economics Assignment Report
Building Economics Assignment ReportBuilding Economics Assignment Report
Building Economics Assignment Reportashleyyeap
 
Culture & History 2- Project 2
Culture & History 2- Project 2Culture & History 2- Project 2
Culture & History 2- Project 2Clement Seong
 
CULTURE PROJECT 2 REPORT
CULTURE PROJECT 2 REPORTCULTURE PROJECT 2 REPORT
CULTURE PROJECT 2 REPORTDarshiini Vig
 
Building Economics Cost Plan Report
Building Economics Cost Plan ReportBuilding Economics Cost Plan Report
Building Economics Cost Plan ReportFarah Sham
 
Chhabra Thermal Power Plant Report By Chandra Mohan Lodha
Chhabra Thermal Power Plant Report By Chandra Mohan LodhaChhabra Thermal Power Plant Report By Chandra Mohan Lodha
Chhabra Thermal Power Plant Report By Chandra Mohan LodhaChandra Mohan Lodha
 
Case Study of Changi Airport,Singapore
Case Study of Changi Airport,SingaporeCase Study of Changi Airport,Singapore
Case Study of Changi Airport,Singaporeeileen_0692
 
Solaris, Singapore passive design strategies report
Solaris, Singapore passive design strategies reportSolaris, Singapore passive design strategies report
Solaris, Singapore passive design strategies reportCarra Chin
 
Studio 6 Design Report
Studio 6 Design ReportStudio 6 Design Report
Studio 6 Design ReportIvy Yee
 
Building science report [singapore]
Building science report [singapore] Building science report [singapore]
Building science report [singapore] Soh Shing
 
Building science report [singapore] final
Building science report [singapore] finalBuilding science report [singapore] final
Building science report [singapore] finalmiranazrin
 
Building science report [singapore] final
Building science report [singapore] finalBuilding science report [singapore] final
Building science report [singapore] finalJannah Jailani
 
Bs 2 group assignment
Bs 2 group assignmentBs 2 group assignment
Bs 2 group assignmentShze Hwa Lee
 
Buildingservices2 bld60503
Buildingservices2 bld60503Buildingservices2 bld60503
Buildingservices2 bld60503Kailyn Lee
 
Ultimatefinalservicereport
UltimatefinalservicereportUltimatefinalservicereport
UltimatefinalservicereportTeo Kean Hui
 
SAMEH AMEEN PORTFOLIO 2022.pdf
SAMEH AMEEN PORTFOLIO 2022.pdfSAMEH AMEEN PORTFOLIO 2022.pdf
SAMEH AMEEN PORTFOLIO 2022.pdfSAMEH AMEEN
 
Research Report on Menara Maybank
Research Report on Menara MaybankResearch Report on Menara Maybank
Research Report on Menara MaybankSheau Hui Tan
 
Culture and History II: Menara Maybank Report
Culture and History II: Menara Maybank ReportCulture and History II: Menara Maybank Report
Culture and History II: Menara Maybank ReportEuxuan Ong
 

Similar to Final ent full report (20)

Building Economics Assignment Report
Building Economics Assignment ReportBuilding Economics Assignment Report
Building Economics Assignment Report
 
Report
ReportReport
Report
 
Culture & History 2- Project 2
Culture & History 2- Project 2Culture & History 2- Project 2
Culture & History 2- Project 2
 
CULTURE PROJECT 2 REPORT
CULTURE PROJECT 2 REPORTCULTURE PROJECT 2 REPORT
CULTURE PROJECT 2 REPORT
 
Building Economics Cost Plan Report
Building Economics Cost Plan ReportBuilding Economics Cost Plan Report
Building Economics Cost Plan Report
 
Chhabra Thermal Power Plant Report By Chandra Mohan Lodha
Chhabra Thermal Power Plant Report By Chandra Mohan LodhaChhabra Thermal Power Plant Report By Chandra Mohan Lodha
Chhabra Thermal Power Plant Report By Chandra Mohan Lodha
 
Case Study of Changi Airport,Singapore
Case Study of Changi Airport,SingaporeCase Study of Changi Airport,Singapore
Case Study of Changi Airport,Singapore
 
Final document
Final documentFinal document
Final document
 
Solaris, Singapore passive design strategies report
Solaris, Singapore passive design strategies reportSolaris, Singapore passive design strategies report
Solaris, Singapore passive design strategies report
 
madhu
madhumadhu
madhu
 
Studio 6 Design Report
Studio 6 Design ReportStudio 6 Design Report
Studio 6 Design Report
 
Building science report [singapore]
Building science report [singapore] Building science report [singapore]
Building science report [singapore]
 
Building science report [singapore] final
Building science report [singapore] finalBuilding science report [singapore] final
Building science report [singapore] final
 
Building science report [singapore] final
Building science report [singapore] finalBuilding science report [singapore] final
Building science report [singapore] final
 
Bs 2 group assignment
Bs 2 group assignmentBs 2 group assignment
Bs 2 group assignment
 
Buildingservices2 bld60503
Buildingservices2 bld60503Buildingservices2 bld60503
Buildingservices2 bld60503
 
Ultimatefinalservicereport
UltimatefinalservicereportUltimatefinalservicereport
Ultimatefinalservicereport
 
SAMEH AMEEN PORTFOLIO 2022.pdf
SAMEH AMEEN PORTFOLIO 2022.pdfSAMEH AMEEN PORTFOLIO 2022.pdf
SAMEH AMEEN PORTFOLIO 2022.pdf
 
Research Report on Menara Maybank
Research Report on Menara MaybankResearch Report on Menara Maybank
Research Report on Menara Maybank
 
Culture and History II: Menara Maybank Report
Culture and History II: Menara Maybank ReportCulture and History II: Menara Maybank Report
Culture and History II: Menara Maybank Report
 

More from Amelisa Collins (20)

Ent final project (2)
Ent final project (2)Ent final project (2)
Ent final project (2)
 
Compilationd
CompilationdCompilationd
Compilationd
 
Theoris
TheorisTheoris
Theoris
 
Text3
Text3Text3
Text3
 
Text1
Text1Text1
Text1
 
Synopsis template to au_march 2018
Synopsis template to au_march 2018Synopsis template to au_march 2018
Synopsis template to au_march 2018
 
Print th isbusstop report
Print th isbusstop reportPrint th isbusstop report
Print th isbusstop report
 
Dimension final
Dimension finalDimension final
Dimension final
 
Bcon compilation-final-ilovepdf-compressed
Bcon compilation-final-ilovepdf-compressedBcon compilation-final-ilovepdf-compressed
Bcon compilation-final-ilovepdf-compressed
 
Dtc report final
Dtc report finalDtc report final
Dtc report final
 
New doc 5
New doc 5New doc 5
New doc 5
 
Dpjcover
DpjcoverDpjcover
Dpjcover
 
Dpj4
Dpj4Dpj4
Dpj4
 
Dpj4 3
Dpj4 3Dpj4 3
Dpj4 3
 
Dpjcover
DpjcoverDpjcover
Dpjcover
 
Conceptflim
ConceptflimConceptflim
Conceptflim
 
New doc 25 (3)
New doc 25 (3)New doc 25 (3)
New doc 25 (3)
 
Design project two brief rev b (1)
Design project two   brief rev b (1)Design project two   brief rev b (1)
Design project two brief rev b (1)
 
Design project one full brief
Design project one full   briefDesign project one full   brief
Design project one full brief
 
itd project 1a
itd project 1aitd project 1a
itd project 1a
 

Recently uploaded

College Call Girls Pune Mira 9907093804 Short 1500 Night 6000 Best call girls...
College Call Girls Pune Mira 9907093804 Short 1500 Night 6000 Best call girls...College Call Girls Pune Mira 9907093804 Short 1500 Night 6000 Best call girls...
College Call Girls Pune Mira 9907093804 Short 1500 Night 6000 Best call girls...Miss joya
 
Russian Call Girls Chickpet - 7001305949 Booking and charges genuine rate for...
Russian Call Girls Chickpet - 7001305949 Booking and charges genuine rate for...Russian Call Girls Chickpet - 7001305949 Booking and charges genuine rate for...
Russian Call Girls Chickpet - 7001305949 Booking and charges genuine rate for...narwatsonia7
 
VIP Call Girls Pune Vani 9907093804 Short 1500 Night 6000 Best call girls Ser...
VIP Call Girls Pune Vani 9907093804 Short 1500 Night 6000 Best call girls Ser...VIP Call Girls Pune Vani 9907093804 Short 1500 Night 6000 Best call girls Ser...
VIP Call Girls Pune Vani 9907093804 Short 1500 Night 6000 Best call girls Ser...Miss joya
 
Russian Call Girl Brookfield - 7001305949 Escorts Service 50% Off with Cash O...
Russian Call Girl Brookfield - 7001305949 Escorts Service 50% Off with Cash O...Russian Call Girl Brookfield - 7001305949 Escorts Service 50% Off with Cash O...
Russian Call Girl Brookfield - 7001305949 Escorts Service 50% Off with Cash O...narwatsonia7
 
Bangalore Call Girls Majestic 📞 9907093804 High Profile Service 100% Safe
Bangalore Call Girls Majestic 📞 9907093804 High Profile Service 100% SafeBangalore Call Girls Majestic 📞 9907093804 High Profile Service 100% Safe
Bangalore Call Girls Majestic 📞 9907093804 High Profile Service 100% Safenarwatsonia7
 
Call Girls Service Pune Vaishnavi 9907093804 Short 1500 Night 6000 Best call ...
Call Girls Service Pune Vaishnavi 9907093804 Short 1500 Night 6000 Best call ...Call Girls Service Pune Vaishnavi 9907093804 Short 1500 Night 6000 Best call ...
Call Girls Service Pune Vaishnavi 9907093804 Short 1500 Night 6000 Best call ...Miss joya
 
Aspirin presentation slides by Dr. Rewas Ali
Aspirin presentation slides by Dr. Rewas AliAspirin presentation slides by Dr. Rewas Ali
Aspirin presentation slides by Dr. Rewas AliRewAs ALI
 
Vip Call Girls Anna Salai Chennai 👉 8250192130 ❣️💯 Top Class Girls Available
Vip Call Girls Anna Salai Chennai 👉 8250192130 ❣️💯 Top Class Girls AvailableVip Call Girls Anna Salai Chennai 👉 8250192130 ❣️💯 Top Class Girls Available
Vip Call Girls Anna Salai Chennai 👉 8250192130 ❣️💯 Top Class Girls AvailableNehru place Escorts
 
Artifacts in Nuclear Medicine with Identifying and resolving artifacts.
Artifacts in Nuclear Medicine with Identifying and resolving artifacts.Artifacts in Nuclear Medicine with Identifying and resolving artifacts.
Artifacts in Nuclear Medicine with Identifying and resolving artifacts.MiadAlsulami
 
Call Girls Doddaballapur Road Just Call 7001305949 Top Class Call Girl Servic...
Call Girls Doddaballapur Road Just Call 7001305949 Top Class Call Girl Servic...Call Girls Doddaballapur Road Just Call 7001305949 Top Class Call Girl Servic...
Call Girls Doddaballapur Road Just Call 7001305949 Top Class Call Girl Servic...narwatsonia7
 
Call Girls Chennai Megha 9907093804 Independent Call Girls Service Chennai
Call Girls Chennai Megha 9907093804 Independent Call Girls Service ChennaiCall Girls Chennai Megha 9907093804 Independent Call Girls Service Chennai
Call Girls Chennai Megha 9907093804 Independent Call Girls Service ChennaiNehru place Escorts
 
VIP Call Girls Indore Kirti 💚😋 9256729539 🚀 Indore Escorts
VIP Call Girls Indore Kirti 💚😋  9256729539 🚀 Indore EscortsVIP Call Girls Indore Kirti 💚😋  9256729539 🚀 Indore Escorts
VIP Call Girls Indore Kirti 💚😋 9256729539 🚀 Indore Escortsaditipandeya
 
High Profile Call Girls Jaipur Vani 8445551418 Independent Escort Service Jaipur
High Profile Call Girls Jaipur Vani 8445551418 Independent Escort Service JaipurHigh Profile Call Girls Jaipur Vani 8445551418 Independent Escort Service Jaipur
High Profile Call Girls Jaipur Vani 8445551418 Independent Escort Service Jaipurparulsinha
 
Kesar Bagh Call Girl Price 9548273370 , Lucknow Call Girls Service
Kesar Bagh Call Girl Price 9548273370 , Lucknow Call Girls ServiceKesar Bagh Call Girl Price 9548273370 , Lucknow Call Girls Service
Kesar Bagh Call Girl Price 9548273370 , Lucknow Call Girls Servicemakika9823
 
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipur
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls JaipurCall Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipur
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipurparulsinha
 
Call Girls Colaba Mumbai ❤️ 9920874524 👈 Cash on Delivery
Call Girls Colaba Mumbai ❤️ 9920874524 👈 Cash on DeliveryCall Girls Colaba Mumbai ❤️ 9920874524 👈 Cash on Delivery
Call Girls Colaba Mumbai ❤️ 9920874524 👈 Cash on Deliverynehamumbai
 
Call Girls Service Noida Maya 9711199012 Independent Escort Service Noida
Call Girls Service Noida Maya 9711199012 Independent Escort Service NoidaCall Girls Service Noida Maya 9711199012 Independent Escort Service Noida
Call Girls Service Noida Maya 9711199012 Independent Escort Service NoidaPooja Gupta
 
VIP Call Girls Pune Vrinda 9907093804 Short 1500 Night 6000 Best call girls S...
VIP Call Girls Pune Vrinda 9907093804 Short 1500 Night 6000 Best call girls S...VIP Call Girls Pune Vrinda 9907093804 Short 1500 Night 6000 Best call girls S...
VIP Call Girls Pune Vrinda 9907093804 Short 1500 Night 6000 Best call girls S...Miss joya
 
Russian Call Girls in Pune Tanvi 9907093804 Short 1500 Night 6000 Best call g...
Russian Call Girls in Pune Tanvi 9907093804 Short 1500 Night 6000 Best call g...Russian Call Girls in Pune Tanvi 9907093804 Short 1500 Night 6000 Best call g...
Russian Call Girls in Pune Tanvi 9907093804 Short 1500 Night 6000 Best call g...Miss joya
 
CALL ON ➥9907093804 🔝 Call Girls Hadapsar ( Pune) Girls Service
CALL ON ➥9907093804 🔝 Call Girls Hadapsar ( Pune)  Girls ServiceCALL ON ➥9907093804 🔝 Call Girls Hadapsar ( Pune)  Girls Service
CALL ON ➥9907093804 🔝 Call Girls Hadapsar ( Pune) Girls ServiceMiss joya
 

Recently uploaded (20)

College Call Girls Pune Mira 9907093804 Short 1500 Night 6000 Best call girls...
College Call Girls Pune Mira 9907093804 Short 1500 Night 6000 Best call girls...College Call Girls Pune Mira 9907093804 Short 1500 Night 6000 Best call girls...
College Call Girls Pune Mira 9907093804 Short 1500 Night 6000 Best call girls...
 
Russian Call Girls Chickpet - 7001305949 Booking and charges genuine rate for...
Russian Call Girls Chickpet - 7001305949 Booking and charges genuine rate for...Russian Call Girls Chickpet - 7001305949 Booking and charges genuine rate for...
Russian Call Girls Chickpet - 7001305949 Booking and charges genuine rate for...
 
VIP Call Girls Pune Vani 9907093804 Short 1500 Night 6000 Best call girls Ser...
VIP Call Girls Pune Vani 9907093804 Short 1500 Night 6000 Best call girls Ser...VIP Call Girls Pune Vani 9907093804 Short 1500 Night 6000 Best call girls Ser...
VIP Call Girls Pune Vani 9907093804 Short 1500 Night 6000 Best call girls Ser...
 
Russian Call Girl Brookfield - 7001305949 Escorts Service 50% Off with Cash O...
Russian Call Girl Brookfield - 7001305949 Escorts Service 50% Off with Cash O...Russian Call Girl Brookfield - 7001305949 Escorts Service 50% Off with Cash O...
Russian Call Girl Brookfield - 7001305949 Escorts Service 50% Off with Cash O...
 
Bangalore Call Girls Majestic 📞 9907093804 High Profile Service 100% Safe
Bangalore Call Girls Majestic 📞 9907093804 High Profile Service 100% SafeBangalore Call Girls Majestic 📞 9907093804 High Profile Service 100% Safe
Bangalore Call Girls Majestic 📞 9907093804 High Profile Service 100% Safe
 
Call Girls Service Pune Vaishnavi 9907093804 Short 1500 Night 6000 Best call ...
Call Girls Service Pune Vaishnavi 9907093804 Short 1500 Night 6000 Best call ...Call Girls Service Pune Vaishnavi 9907093804 Short 1500 Night 6000 Best call ...
Call Girls Service Pune Vaishnavi 9907093804 Short 1500 Night 6000 Best call ...
 
Aspirin presentation slides by Dr. Rewas Ali
Aspirin presentation slides by Dr. Rewas AliAspirin presentation slides by Dr. Rewas Ali
Aspirin presentation slides by Dr. Rewas Ali
 
Vip Call Girls Anna Salai Chennai 👉 8250192130 ❣️💯 Top Class Girls Available
Vip Call Girls Anna Salai Chennai 👉 8250192130 ❣️💯 Top Class Girls AvailableVip Call Girls Anna Salai Chennai 👉 8250192130 ❣️💯 Top Class Girls Available
Vip Call Girls Anna Salai Chennai 👉 8250192130 ❣️💯 Top Class Girls Available
 
Artifacts in Nuclear Medicine with Identifying and resolving artifacts.
Artifacts in Nuclear Medicine with Identifying and resolving artifacts.Artifacts in Nuclear Medicine with Identifying and resolving artifacts.
Artifacts in Nuclear Medicine with Identifying and resolving artifacts.
 
Call Girls Doddaballapur Road Just Call 7001305949 Top Class Call Girl Servic...
Call Girls Doddaballapur Road Just Call 7001305949 Top Class Call Girl Servic...Call Girls Doddaballapur Road Just Call 7001305949 Top Class Call Girl Servic...
Call Girls Doddaballapur Road Just Call 7001305949 Top Class Call Girl Servic...
 
Call Girls Chennai Megha 9907093804 Independent Call Girls Service Chennai
Call Girls Chennai Megha 9907093804 Independent Call Girls Service ChennaiCall Girls Chennai Megha 9907093804 Independent Call Girls Service Chennai
Call Girls Chennai Megha 9907093804 Independent Call Girls Service Chennai
 
VIP Call Girls Indore Kirti 💚😋 9256729539 🚀 Indore Escorts
VIP Call Girls Indore Kirti 💚😋  9256729539 🚀 Indore EscortsVIP Call Girls Indore Kirti 💚😋  9256729539 🚀 Indore Escorts
VIP Call Girls Indore Kirti 💚😋 9256729539 🚀 Indore Escorts
 
High Profile Call Girls Jaipur Vani 8445551418 Independent Escort Service Jaipur
High Profile Call Girls Jaipur Vani 8445551418 Independent Escort Service JaipurHigh Profile Call Girls Jaipur Vani 8445551418 Independent Escort Service Jaipur
High Profile Call Girls Jaipur Vani 8445551418 Independent Escort Service Jaipur
 
Kesar Bagh Call Girl Price 9548273370 , Lucknow Call Girls Service
Kesar Bagh Call Girl Price 9548273370 , Lucknow Call Girls ServiceKesar Bagh Call Girl Price 9548273370 , Lucknow Call Girls Service
Kesar Bagh Call Girl Price 9548273370 , Lucknow Call Girls Service
 
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipur
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls JaipurCall Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipur
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipur
 
Call Girls Colaba Mumbai ❤️ 9920874524 👈 Cash on Delivery
Call Girls Colaba Mumbai ❤️ 9920874524 👈 Cash on DeliveryCall Girls Colaba Mumbai ❤️ 9920874524 👈 Cash on Delivery
Call Girls Colaba Mumbai ❤️ 9920874524 👈 Cash on Delivery
 
Call Girls Service Noida Maya 9711199012 Independent Escort Service Noida
Call Girls Service Noida Maya 9711199012 Independent Escort Service NoidaCall Girls Service Noida Maya 9711199012 Independent Escort Service Noida
Call Girls Service Noida Maya 9711199012 Independent Escort Service Noida
 
VIP Call Girls Pune Vrinda 9907093804 Short 1500 Night 6000 Best call girls S...
VIP Call Girls Pune Vrinda 9907093804 Short 1500 Night 6000 Best call girls S...VIP Call Girls Pune Vrinda 9907093804 Short 1500 Night 6000 Best call girls S...
VIP Call Girls Pune Vrinda 9907093804 Short 1500 Night 6000 Best call girls S...
 
Russian Call Girls in Pune Tanvi 9907093804 Short 1500 Night 6000 Best call g...
Russian Call Girls in Pune Tanvi 9907093804 Short 1500 Night 6000 Best call g...Russian Call Girls in Pune Tanvi 9907093804 Short 1500 Night 6000 Best call g...
Russian Call Girls in Pune Tanvi 9907093804 Short 1500 Night 6000 Best call g...
 
CALL ON ➥9907093804 🔝 Call Girls Hadapsar ( Pune) Girls Service
CALL ON ➥9907093804 🔝 Call Girls Hadapsar ( Pune)  Girls ServiceCALL ON ➥9907093804 🔝 Call Girls Hadapsar ( Pune)  Girls Service
CALL ON ➥9907093804 🔝 Call Girls Hadapsar ( Pune) Girls Service
 

Final ent full report

  • 1. SCHOOL OF ARCHITECTURE, BUILDING & DESIGN Centre for Modern Architecture Studies in Southeast Asia Master of Architecture ENVIRONMENT AND TECHNOLOGY II (ARC71003) Project 2 : Service Core Optimal Proposal (Individual) Student Name: Heng Sy Hua Student ID: 0321999
  • 2. CONTENT 1.0 INTRODUCTION 2.0 SITE INTRODUCTION 3.0 SITE ANALYSIS 3.1 Sun path and shadow analysis 3.2 Temperature and Humidity 3.3 Wind Flow 4.0 BUILDING INTRODUCTION 4.1 Building Information 4.2 Purpose Group 4.3 Occupancy Load 5.0 PASSIVE FIRE PROTECTION 5.1 Fire Appliance Access 5.2 Hydrant Location 5.3 Means of Escape 6.0 ACTIVE FIRE PROTECTION 6.1 Lift and Service Core 7.0 REFERENCE
  • 3. 1.0 INTRODUCTION This module emphasizes the role of building technology and sustainability in building design by analyzing and evaluating complex buildings or a group of buildings. It regards architecture as the integration of environment, technology and architecture. These three factors are considered to be an indispensable part of architectural design and can be rigorously evaluated through theory. The objectives of the project are as follows: • Introduce standards and regulations for building core design. • Use technology as a functional element or function of architectural design. • Integrate technical and environmental factors to improve building efficiency and practicability.
  • 4. 2.0 SITE INTRODUCTION Figure 1: Location of Proposed site. Klang, the official royal town of Klang Klang is a royal town and the former capital of Selangor, Malaysia. Before the rise of Kuala Lumpur, it was the private capital of Selangor, and now the capital is Shah Alam. The city currently includes a population of 240,000 in Klang and 12,000 in the city center. Klang is divided into two main parts, namely North Klang and South Klang. Our site is located in North Klang. Similar to the south side, the north side of Klang has a large number of commercial and religious areas. However, North Kland, like many other cities in Malaysia, is slowly
  • 5. suffering from the decline of the city. There is not much future development and social participation here. Therefore, the identity of North Klang has not yet been reflected. There are few issues identifies on site, which are :
  • 6. 3.0 SITE ANALYSIS Sun Path and shadow analysis Figure 3: Sunpath on site. Figure 4: Shadow analysis of three different times of the year The site is surrounded by mid-rise buildings. The site is just slightly shaded in the morning from the morning sun. The site is fully exposed to afternoon sun at 12pm. On the other hand, the site is almost fully shaded by the building located beside the site. Therefore, the sun-shading of the building should focus on the morning sun from the east and afternoon sun.
  • 7. Temperature and Humidity Figure 5: Average annual temperature of Klang According to the date reading from the previous 12 months, the average annual temperature of Klang is 27​°C. The minimum is 23°C while the maximum temperature is  33°C.  Figure 6: Average annual humidity in Klang The average annual humidity of Klang is 75% ​. The minimum humidity is 70% while the  maximum humidity goes up to 80%.     Klang has a tropical hot and humid climate. Therefore, the building design aims to minimise direct heat gain from sun and maximise natural ventilation. Besides, the building also aims to achieve thermal comfort, ranging from 20​°C to 22°C according to  the psychrometric chart. Therefore, the choice of materials and configuration of forms  are carefully chosen and designed to achieve better thermal comfort for the users.  
  • 8. Wind Flow Figure 7: Prevailing Wind direction on site. On average, the dominant wind direction at Klang, is blowing from south-southeast and northeast. Figure 8: Annual average wind speed
  • 9. Figure 9: Wind flow diagram on site. The average wind speed is at 3m/s throughout the year except for November which has wind up to 2m/s. Highest wind blow is from the south side of the site with 2.15m/s
  • 10. 4.0 BUILDING INTRODUCTION 4.1 Building information Figure 10 : Perspective view or Klang CivIc Center The Urban Design Studio embarks on a proposal for a civic center situated at North Klang. The Klang Civic center is inspired by Galeri of Sultan Abdul Aziz in South Klang which is the informal tourist center for the tourist. The Klang Civic Center aims not only to be a civic center that serves the local community, but also a tourist center that welcomes tourists. By having an intention to serve these two main users groups, the civic center will be a place where the tourists meet the locals. The proposed Klang Civic Center is a 4-storey high with one underground car park basement. The gross floor area of the building is approximately 5,000 square meter. The ground floor is a public space that opened up to the public. There are tourist information centers, bazaars, markets, green spaces and courtyards. The others levels concentrated on semi-open and private usage.There are, workshops, studios, gallery, library, administration offices and seminars rooms.
  • 11. Disposal TNB Firecontrol gensett MSB Shop tuorist center locker room WC Shop UP 1 3 6 8 10 12 14 16 18 DN UP 1 3 6 8 10 12 14 16 18 DN UPDN UP 12345 6 A B C D lift lobby WC Shop Shop GROUND FLOOR PLAN 1:350 PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION
  • 12. 12345 6 A B C D UPDN UPDN UP DN 18 16 14 12 10 8 6 3 1 UP UP 1 3 6 8 10 12 14 16 18 DN studio 2 studio 1 meeting room office Workshop Workshop WC WCWC 1235 6 Workshop FIRST FLOOR PLAN 1:350 PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION
  • 13. Workshop Seminar room 1 Private office Shop Shop Shop Bridge to carpark Seminar room 2 Manager office Manager office file room store room UP 1 3 6 8 10 12 14 16 18 DN UPDN UPDN UP 1 3 6 8 10 12 14 16 18 DN pantry UP DN WC WC WC Workshop Object library Family room 12345 6 A B C D 2ND FLOOR PLAN 1:350 PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION
  • 14. Exhibition Space store event space Librarian office discussion Audio room UPDN UPDN Workshop UP UP 1 3 6 8 10 12 14 16 18 DN UP 1 3 6 8 10 12 14 16 18 DN 12345 6 A B C D library DN WC WC WC 1235 6 3RD FLOOR PLAN 1:350 PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION
  • 15. Roof top cafe UPDN DN UP 1 3 6 8 10 12 14 16 18 DN UP 1 3 6 8 10 12 14 16 18 DN 12345 6 A B C D HERBS GARDEN outdoor playground bbq area souvenier shop 4TH FLOOR PLAN 1:350 PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION
  • 16. 4.2 Purpose Group Based on Selangor Uniform Building By-Laws 1986 Fifth Schedule, the Klang Civic Center are under Institutional and Shop purpose groups. Table 1: Designated for purpose groups according to Fifth Schedule By Law Clause 134: Designation of purpose group For the purpose of this Part every building or compartment shall be regarded according to its use or intended use as falling within one of the purpose groups set out in the Fifth Schedule to these By-laws and, where a building is divided into compartments, used or intended to .be used for different purposes, the purpose group of each compartment shall be determined separately: Provided that where the whole or part of a building or compartment, as the case may be, is used or intended to be used for more than one purpose, only the main purpose of use of that building or compartment shall be taken into account in determining into which purpose group it falls. By Law Clause 138: Designation of purpose group The following walls and floors in buildings shall be constructed as compartment walls or compartment floors:
  • 17. (a) any floor m a building of Purpose Group 2 (Institutional) (b) any wall or floor separating a flat or maisonette from any other part of ·the same building; (c) any wall or floor separating part of a building from any other part of the same building which is used or intended to be used mainly for a purpose falling within a different purpose group as set out in the Fifth Schedule to these By-laws; and (d) any floor immediately over a basement storey if such basement storey has an area exceeding 100 square metres. 4.3 Occupancy Load The occupancy load and capacity exits are based on the following By-Laws: By Law Clause 175: Calculation of occupant load. Calculation of occupancy loads and capacity of exits shall be in accordance with provisions of the Seventh Schedule to these By-Laws. Based on Selangor Uniform Building By-Laws 1986 Seventh Schedule, the calculation of occupancy load and capacity of exits for shops purpose group are as follow:
  • 18. Table 2: Capacity Exits of each purpose Group are stated. By Law Clause 167: Horizontal Exits (1) Except as provided for in by-law 194 every compartment shall be provided with at least two storey exits located as far as practical from each other and in no case closer than 4.5 metres and in such position that the travel distances specified in the Seventh Schedule to these By-laws are not exceeded. (2) The width of storey exits shall be in accordance with the provisions in the Seventh Schedule to these By-laws. By Law Clause 168: Staircases (1) Except as provided for in by-law 194 every upper floor shall have means of egress via at least two separate staircases. (2) Staircases shall be of such width that in the event of any one staircase not being available for escape purposes the remaining staircases shall accommodate the highest occupancy load of any one floor discharging into it ,calculated in accordance with provisions in the Seventh schedule to these By-laws. (3) The required width of a staircase shall be the clear width between walls but handrails may be permitted to encroach on this width to a maximum of 75 millimetres. (4) The required width of a staircase shall be maintained throughout its length including at landings. (5) Doors giving access to staircases shall be so positioned that their swing shall at no point encroach on the required width of the staircase or landing. By Law Clause 169: Exit Route No exit route may reduce in width along its path of travel from the storey exit to the final exit. By Law Clause 170: Egress through unenclosed openings Where unenclosed openings are permitted between floors and for a mezzanine floor, egress may be by way of an open staircase to an adjacent floor and thence to a story exit: (a) the layout is such that a fire originating anywhere within the compartment will be. obvious to the occupants of all communicating levels or areas; (b) the travel distances specified in the Seventh Schedule to these By-laws are not exceeded; (c) only 50% of the occupants of a floor are assumed to use the open staircase and storey exits are provided at every level to accommodate the other 50% of the occupants
  • 19. of that level in accordance with the provisions of the Seventh Schedule to these by-laws; and (d) the storey exits on the principal floor through which other levels discharge are designed to handle the occupant; of that floor plus 50% .of the occupants from the adjacent levels discharging through it. By Law Clause 171: Horizontal Exits (1) Where appropriate, horizontal exits may be provided in lieu of other exits. (2) Where horizontal exits are provided protected staircases and final exits need only be of a width to accommodate the occupancy load of the larger compartment or building discharging into it so long as the total number of exit widths provided is not reduced to less than half that would otherwise be required for the whole building. (3) For institutional occupancies the total exit capacity other than horizontal exits shall not be reduced by more than one-third that would otherwise be required for the entire area of the building.
  • 20. 5.0 PASSIVE FIRE PROTECTION 5.1 Perimeter Appliances Access The fire appliances access is based on the following By Laws from Selangor Uniform Building By-Laws 1986: By Law Clause 140: Fire Appliance access All buildings in excess of 7000 cubic metres shall abut upon a street or road or open space of not less than 12 metres width and accessible to fire brigade appliances. The proportion of the building abutting the street, road or open space shall be in accordance with the following scale: Table 3 : Building volume and required proportion of perimeter access The volume of Klang Civic Center is approximately ​31,910 cubic meter​. Therefore, it is under the range of 28,000 to 56,000 cubic meter. Therefore, at least ​one forth​ of the perimeter of the building need be abutting the street, road or open space. The perimeter of the building is​ 247m. ​Thus, at least ​61.75m perimeter of the buil​ding needs to be abutting a road or open space of not less than 12 metres width and accessible to fire brigade appliances.
  • 21. 5.2 Hydrant Location By Law Clause 225: Detecting and extinguishing fire (1) Every building shall be provided with means of detecting extinguishing fire. and extinguishing fire and with fire alarms together with illuminated exit signs in accordance with the requirements as specified in the Tenth Schedule to these By-laws. (2) Every building shall be served by at least one fire hydrant located not more than 91.5 metres from the nearest point of fire brigade access. (3) Depending on the size and location of the building and the provision of access for fire appliances, additional fire hydrants shall be provided as may be required by the Fire Authority. There is an existing fire hydrant placed beside the site. Therefore, 2 new fire hydrants with a 45m radius are added on site to achieve full coverage of the building. The hydrant proposed is located not less than 2m from the Klang Civic Center and between 0.61m to 2.4m from the fire appliances access.
  • 22. Disposal TNB Firecontrol gensett MSB Shop tuorist center locker room WC Shop UP 1 3 6 8 10 12 14 16 18 DN UP 1 3 6 8 10 12 14 16 18 DN UPDN UPDN 12345 6 A B C D lift lobby WC Shop Shop H H SITE PLAN 1:500 PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION
  • 23. 5.3 Means of Escape According to Uniform Building By-laws 1984 Seventh Schedule, as this project falls under the purpose ground of Institutional and Shops, the maximum travel distances for sprinkled design is 45m while the dead end limit is 15m. Table 4: Maximum running distances Besides, the travel distance are calculated based on following by-laws: By Law Clause 165 : Measurement of travel distance to exist. (1) The travel distance to an exit shall be measured on the floor or other walking surface along the centre line of the natural path of travel, starting 0.300 metre from the most remote point of occupancy, curving around any comers or obstructions with 0.300 metre clearance therefrom and ending at the storey exit. Where measurement includes stairs, it shall be taken in the plane of the trend noising. (2) In the case of open areas the distance to exits shall be measured from the most remote point of occupancy provided that the direct distance shall not exceed two-thirds the permitted travel distance. (3} In the case of "individual rooms which are subject to occupancy of not more than six persons, the travel distance shall be measured from the doors of such rooms: Provided that the travel distance from any point in the room to the room door does not exceed 15 metres. (4) The maximum travel distances to exits and dead end limits shall be as specified in the Seventh Schedule of theSe By-laws. By-law Clause 166: Exits to be accessible at all times. 1) Except as permitted by by-law 167 not less than two separate exits shall be provided from each storey together with such additional exits as may be necessary
  • 24. 2) The exits shall be sited and the exit access shall be so arranged that the exits are within the limits of travel distance as specified in the Seventh Schedule to these By-laws and are readily accessible at all times. By-law Clause 167: Storey exits. 1) Except as provided for in by-law 194 every compartment shall be provided with at least two storey exits located as far as practical from each other and in no case closer than 4.5 metres and in such position that the travel distances specified in the Seventh Schedule to these By-laws are not exceeded. 2) The width of storey exits shall be in accordance with the provisions the Seventh Schedule to these By-laws. By-law Clause 170: Egress through unenclosed openings. Where unenclosed openings are permitted between floors and for a mezzanine floor, egress may be by way of an open staircase to an adjacent floor and thence to a story exit: b) The travel distances specified in the Seventh Schedule to these By-laws are not exceeded. The ground floor of Klang Civic Center is naturally ventilated with an open plan. Therefore, users can safely exits the building in ground floor. Thus, no travel distance are measured.
  • 25. 12345 6 A B C D UPDN UPDN UP DN 18 16 14 12 10 8 6 3 1 UP UP 1 3 6 8 10 12 14 16 18 DN studio 2 studio 1 meeting room office Workshop Workshop WC WCWC 1235 6 43285mm 34360mm 30412mm 37452mm Workshop FIRST FLOOR PLAN 1:350 PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION
  • 26. Workshop Seminar room 1 Private office Shop Shop Shop Bridge to carpark Seminar room 2 Manager office Manager office file room store room UP 1 3 6 8 10 12 14 16 18 DN UPDN UPDN UP 1 3 6 8 10 12 14 16 18 DN pantry UP DN WC WC WC Workshop Object library Family room 12345 6 A B C D 44368mm 34800m m 40182mm 33803mm 2ND FLOOR PLAN 1:350 PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION
  • 27. Exhibition Space store event space Librarian office discussion Audio room UPDN UPDN Workshop UP UP 1 3 6 8 10 12 14 16 18 DN UP 1 3 6 8 10 12 14 16 18 DN 12345 6 A B C D library DN WC WC WC 1235 6 43721mm 27297mm 32860mm 30983mm 3RD FLOOR PLAN 1:350 PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION
  • 28. Roof top cafe UPDN DN UP 1 3 6 8 10 12 14 16 18 DN UP 1 3 6 8 10 12 14 16 18 DN 12345 6 A B C D HERBS GARDEN outdoor playground bbq area souvenier shop 33803mm 29850mm 15835mm 4TH FLOOR PLAN 1:350 PRODUCED BY AN AUTODESK STUDENT VERSIONPRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION PRODUCEDBYANAUTODESKSTUDENTVERSION
  • 29. 5.4 Escape Provision Computation The escape provision of the building is based on following by-laws : By Law Clause 175 : Calculation of occupant load Calculation of occupancy loads and capacity of exits shall be in accordance with the provisions of the Seventh Schedule to these By-laws. By Law Clause 176 : Computing storey exit widths To compute the required exit width from individual floors of a building- (a) calculate the floor area net or gross whichever is applicable; (b) determine the allowable occupancy load factor from Table; (c) divide the floor area by the number of square metre per person to determine the number of persons for which exits must be provided for that floor; (d) determine from the table the capacity of the type of exit to be used for the purpose group being designed; and (e) calculate the number of units of exit width for each type of exit used based upon the capacity. By Law Clause 177 : Computing number of staircases and staircase widths. The following factors shall be used in computing the exit computing widths: (a) in a multi-storeyed building if x units of exit width are required from each floor the staircases serving those floors do not need to be x times the number of floors served in units of exit width. The staircases need be only wide enough to serve each floor but not less than the minimum width allowed and in every case one of the protected staircases shall be assumed to be inaccessible and the remaining protected staircase shall be of sufficient width and number to accommodate the relevant occupancy; (b) depending on the occupancy, street floor exits have to be sized to handle not only the occupant load of the street floor but also a percentage of the load of the exits discharging to the street floor from floors above and below; (c) exits should never decrease in width along their length of travel and, if two or more exits converge into a commonexit, the common exit should never·be narrower than the sum of the width of the exits converging into it; ·(f) there should be no decrease in width along the path of travel of a staircase. 6.0 ACTIVE FIRE PROTECTION
  • 30. According to the Uniform Building By-laws 1984 Seventh Schedule, the numbers and width of staircase design for Klang Civic Center which falls under Institutional and Shop purpose groups are calculated in Table 5: FLOOR LEVEL PURPOSE GROUP (Based on Fifth Schedule) PROPOSED SPACE Ground Floor Shops (V) Shops First Floor Institutional (II) Workshop, Studio Second Floor Institutional (II) Library, Workshop, Seminar Room, Office Third Floor Institutional (II) Exhibition Space, Workshop, Event Space, Library Forth Floor Shops (V) Souvenir Shop, Roof Top cafe Table 5 :Purpose Group of each floor based on UBBL Fifth Schedule Purpose Group Shop (V) Institutional (II) Institutional (II) Institutional (II) Shop (V) Occupancy Load 3 2 2 2 6 Floor Area (m2) 1679 1182 1154 1160 1078 Occupancy (C/B) 1697/3 = 560 1182 / 2 = 591 1154 / 2 = 557 1160 / 2 = 580 1078/6= 180 Exit Capacity Required 560 / 100 = 5.6 591 / 100 = 5.91 557 / 100 = 5.57 580 / 100 = 5.8 180 / 100 = 1.80 Minimum Exit Width (E x 550mm) 3,080mm 3,245mm 3,063.5mm 3,190mm 990mm Table 6 : Minimum Exit Width of each floor are calculated.
  • 31. Ground floor Main staircase (Protected) 1250mm Secondary staircase 1 1250mm Secondary staircase 2 2000mm Secondary staircase 3 68867mm Total Width 73267mm Assuming the main staircase of the ground floor (1,200mm) is inaccessible, the remaining exit width (73267mm – 1,200mm) is 72,067mm > 3,080mm, and therefore the provision satisfies the By-laws.
  • 32. First floor Main staircase (Protected) 1250mm Secondary staircase 1 1250mm Secondary staircase 2 2000mm Total Width 4500mm Assuming the main staircase of the ground floor (1,250mm) is inaccessible, the remaining exit width (4500mm – 1,200mm) is 3300mm > 3,245mm, and therefore the provision satisfies the By-laws.
  • 33. Second floor Main staircase (Protected) 1250mm Secondary staircase 1 1250mm Secondary staircase 2 2000mm Total Width 4500mm Assuming the main staircase of the ground floor (1,250mm) is inaccessible, the remaining exit width (4500mm – 1,200mm) is 3300mm > 3,063.5mm, and therefore the provision satisfies the By-laws.
  • 34. Third floor Main staircase (Protected) 1250mm Secondary staircase 1 1250mm Secondary staircase 2 2000mm Total Width 4500mm Assuming the main staircase of the ground floor (1,250mm) is inaccessible, the remaining exit width (4500mm – 1,200mm) is 3300mm > 3,190mm, and therefore the provision satisfies the By-laws.
  • 35. Forth floor Main staircase (Protected) 1250mm Secondary staircase 1 1250mm Secondary staircase 2 2000mm Total Width 4500mm Assuming the main staircase of the ground floor (1,250mm) is inaccessible, the remaining exit width (4500mm – 1,200mm) is 3300mm > 990mm, and therefore the provision satisfies the By-laws.
  • 36. 6.0 ACTIVE FIRE PROTECTION 6.1 Lift and Service Core Both main lifts are accessible from the open and natural ventilated corridor at every floor. Service lift are only accessible inside the protected lift lobby. Figure 11 : Ground Floor Plan Drawing indicating location of lift core
  • 37. The provision of lift lobby is based on follow Building By-Laws : By Law Clause 152 : Openings in Lift Shafts. (1) Every opening in a lift shaft or lift entrance shall open into a protected lobby unless other suitable means of protection lift to the opening to the satisfaction of the local authority is provided. These requirements shall not apply to open type industrial and other special buildings as may be approved by the D.G.F.S. (3) No glass shall be used for in landing doors except for vision in which case any vision panel shall or be glazed with wired safety glass, and shall not be more than 0.0161 square metre and the total area of one of more vision panels in any landing door shall be not more than 0.0156 square metre. By Law Clause 153 : Smoke Detector in lift lobbies. (1) All lift lobbies shall be provided with smoke detectors. (2) Liff not opening into a smoke lobby shall not use door reopening devices controlled by light beam or photo-detectors unless incorporated with a force close feature which after thirty seconds of any interruption of the beam causes the door to close within a preset time. By Law Clause 157 : Protected shafts consisting of staircase. A protected staircase or a protected shaft containing a staircase, shall not contain any pipe conveying gas or oil or any ventilation duct other tlian a duct serving only that staircase or shaft. Fire Extinguishing and Alarm System Klang Civic Center is under Institutional and shops group. Therefore, based on Selangor Uniform Building By-laws 1986 Tenth Schedule, the proposed Klang Civic Center requires followings elements: 1. Fire detection 2. Fire alarm 3. Extinguishing system
  • 38. Table 7: above show the requirement for fire extinguisher and alarm system
  • 39. The requirement of fire extinguishing and alarm systems are based on following By-Laws: By Law Clause 225 : Detecting and extinguishing fire. (2) Every building shall be provided with means of detecting and extinguishing fire and with fire alarms together with illuminated exit signs in accordance with requirements as specified in the Tenth Schedule to these By-Laws. By Law Clause 237 : Fire alarm (1) Fire alarm shall be provided in accordance with Tenth schedule to these By Laws. Therefore, Klang Civic Center need to incorporates different systems to achieve optimum fire safety, which includes: 1. Automatic Sprinkler System 2. Hose Reel System 3. Automatic Fire Detector System 4. Manual Electric Fire Alarm System
  • 40. Figure 12 : Detail drawing of Lift core
  • 41. 7.0 REFERENCE 1. Laws of Malaysia. (1986). Selangor uniform building by-laws 1986. Kuala Lumpur: MDC Publishers Sdn. Bhd. 2. Laws of Malaysia. (1984). Uniform building by-laws 1984. Kuala Lumpur: International Law Book Services. 3. Hamzah, A. B. (2006). Guide to fire protection in Malaysia. Kuala Lumpur: The Institute of Fire Engineers (UK) Malaysia Branch.