Analisi delle strutture per prove di suscettività irradiata nell'ambito della sezione RS105 della norma MIL-STD-461G. Pubblicata in occasione del seminario MIL nel 2017.
2. 07/09/2017
2
Explosion in an altitude of
several hundreds of km
(High Altitude EMP –
HEMP)
Gamma ray impulse
Compton effect in the
stratosphere (+ other
effects)
Emission of an
electromagnetic pulse
Irradiation of an area with
a diameter of several
hundreds of km on earth
Nuclear Electromagnetic Pulse (NEMP)
4. 07/09/2017
4
Pulse as per MIL-STD 461 E/F/G
RS105
Rise time (between 10% and 90% points) between
1.8 ns and 2.8 ns (electric field continuously
increasing)
Full width half maximum (FWHM) pulse width
equal to 23 ns ± 5 ns
Peak value of the electric or magnetic field for
each grid position: 0 dB ≤ magnitude ≤ 6 dB above
limit
19. 07/09/2017
19
Mobile NEMP simulator (7.2 m)
7.2 m high radiation line
Approx. EUT size: 5 x 3.5 x 3 m (L x W x H)
Indoor or outdoor installation
7.2 m
Up and ready
in less than 3 h
25. 07/09/2017
25
Custom designed fix NEMP simulators
Succefully realized project of a 25m high, 140m long NEMP simulator
with a 2MV pulse generator
26. 07/09/2017
26
Summary
Montena offers a large range of movable NEMP
simulators with accessories
Experience in design and development of
permanent NEMP simulators
Refurbishment of existing installations
27. montena technology sa
route de montena 89
1728 Rossens
Switzerland
products@montena.com
montena.com
The impulse
to your progress
Thank you
for your attention
Werner Hirschi
Managing Director