This document describes the Guide Right system for fabricating and correcting diagnostic and surgical guides. It involves using Invivo5 and Anatomage software to evaluate a case pre-operatively and plan corrections. Guide posts are placed on a cast and bent using a bending tool to achieve linear and angular corrections as determined by the software. A diagnostic guide is fabricated to verify the planned corrections, then a surgical guide is made incorporating the corrections to accurately place implants. The system allows precision placement through in-office fabrication and evaluation of corrections in 1-2 dimensions.
7. 1st Angular Correction: # 29 1 st Linear Correction:
0.5LingualOffset to the Lingual โช
mm 7ยฐ Bend to the Lingual
tangential cross sectional
Invivo5
8. # 29
2nd Angular Correction: 2 nd Linear Correction
14ยบ Bend mesial 0.5 mm Offset distal
axial cross sectional
Invivo5
Anatomage
Invivo5
Anatomage
tangential volumetric
9. # 29 CLOSE UP indication for 14ยบ Angular Correction
tangential
10. # 30
Initial Alignment
โช 4.1 X 8 mm virtual implant โช
Invivo5
Anatomage
11. # 30
โช Angular Correction: 7ยฐ Bend to the Mesial โช
axial cross sectional
Invivo5
Invivo5
Anatomage
Anatomage
tangential view volumetric
12. # 30 CLOSE UP indication for 7ยฐ Angular Correction
tangential
14. # 31 Angular Correction: 26ยฐ Bend to the Lingual
axial cross sectional
Invivo5
Anatomage
tangential volumetric
15. # 31 CLOSE UP indication for 26ยฐ Lingual Correction
cross section
16. Review of Pre-op Corrections
#29 #30
LINEAR CORRECTIONS ANGULAR CORRECTIONS
1st : 0.5 mm Offset toward the Lingual 7ยฐ Bend to the Mesial
2nd : 0.5 mm Offset toward the Distal
# 31
ANGULAR CORRECTIONS ANGULAR CORRECTIONS
1st : 14ยฐ bend Mesial
26ยฐ Bend to the Lingual
2st : 7ยฐ bend to the Lingual
Cosine is applied to determine correction data.
* see Pythagorean Theorem - COSINE CALCULATION slideshow
17. # 31 - 26ยฐ # 30 - 7ยฐ # 29 - 14ยฐ
3 mm magnetic guide posts 3 mm X 0.5 mm offset
3 mm magnetic guide posts showing angle corrections
29. Guide Rightโข
Products shown in this case
๏ง 1 - 3/32โ drill
๏ง 3 - 3 mm Guide Post
๏ง 3 - 3 mm Guide Sleeve
๏ง 1 - 3 mm X 0.5 mm Magnetic Offset Guide Post
๏ง 3 - 3.3 mm Open Guide Sleeve
๏ง Generation ll โช Guide Post Bending Tool
๏ง Triadยฎ Gel
1.800.314.0065 โข www.deplaque.com
30. Guide Rightโข
Generation ll Bending Tool
10ยฐ example
For more information on use of the bending tool go to
www.deplaque.com โช Guide Rightโข Generation ll Bending Tool
31. Guide Rightโข
GENERATION II โช GUIDE POST BENDING TOOL
SINGLE BEND review
Step 1 Place bending tool plate on a secure flat surface with the degree increments
at the top & the stainless steel bar with the v-cut at the bottom.
Step 2 Locate 3/32โ hole in the center of the v-cut and place the bottom half of the
guide post into the hole. Tighten the set screw.
Step 3 Locate the hole in the bottom of the stylus that you will use that will fit over
the top half of the guide post (3.0 mm, 4.0 mm or 5.0 mm).
Step 4 Fit the stylus over the guide post securely with the point directed at
zero degrees and the bottom of the stylus in contact with the V block.
Step 5 Using the stylus as a lever, bend the guide post to the degree of angle of
correction. You may need to ease the point of the stylus beyond the
point of the desired degree.
Step 6 Loosen screw and remove guide post and the stylus to find the guide post
bent to the desired angle.
32. Guide Rightโข
GENERATION II โช GUIDE POST BENDING TOOL
COMPOUND BEND overview
Step 1 Position a straight or offset guide post in the bending plate, tightening the set
screw against one of the flat surfaces on the lower half of the guide post.
Step 2 The 1st bend can be made to the right or left direction.
Step 3 The set screw is loosened and the guide post is rotated 90 ยฐ next flat surface.
Step 4 The 2nd bend in the second plane is made after rotating the guide post up away
from the surface of the bending plate to register the stylus point back at 0 degrees.
Step 5 Slide the stylus support bar down under the stylus until it supports the stylus.
Tighten the side screws before making the second bend.
Step 6 The second bend can be made in either direction according to the x-ray.
Step 7 Remove the stylus and place the guide post back in the cast with the
appropriate side indicated by a mark facing the buccal or lingual surface.
Be sure the post is in the correct position.
If the post needs to be corrected by a linear movement an offset guide post can be used.
Off sets available in the 3 mm guide post: 0.5,1,1.5, 2.0 ,or 3.0 mm.
33. A System of Components
for the fabrication and correction of diagnostic & surgical templates
in one or two dimensions
๏ง In-office or lab fabrication
๏ง Evaluate with 2D & 3D imaging
๏ง Allows linear and angular correction
๏ง Enables precision implant placement
๏ง Cost effective
1.800.314.0065 โข www.deplaque.com
34. DรฉPlaque
Guide Rightโข Surgical Guide System
fabricate โช evaluate โช correct โช verify โช place
Start With Precision. Place With Confidence.โข
1.800.314.0065 โข www.deplaque.com