Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.

3 serial guide technique

3,123 views

Published on

The Guide Right Surgical Guide System is a system of components for the fabrication and correction of diagnostic and surgical dental implant guides in 1 or 2 dimensions.

Published in: Health & Medicine
  • Be the first to comment

  • Be the first to like this

3 serial guide technique

  1. 1. Serial Guide Technique Featuring: #30 Fabrication of DIAGNOSTIC Guide using:  5.3 Wide Guide Sleeve  Serial Guide Sleeve Inserts  Fabrication Insert (FABIN)  Insert Removal Tool (IRT) SURGICAL Guide in place Serial Inserts Kits are availableDWYER 2.2013
  2. 2. Clinical view of proposed surgery site
  3. 3. Wax set up of #30 tooth
  4. 4. Hole drilled with 3/32” drill through wax up
  5. 5. 3/32” drill in cast indicates the planned prosthetic axis.
  6. 6. The drill is replaced with a 3 mm guide post.
  7. 7. Undercuts blocked out.
  8. 8. Lubricating cast with petroleum jelly prior to adding Triad® Gel
  9. 9. 5.3 Fabrication Insert (FABIN) used to center the 5.3 guide sleeveon the guide post and to prevent Triad® Gel from entering sleeve.
  10. 10. Lingual view of FABIN in 5.3 mm guide sleeve withguide sleeve cleats positioned toward the lingual surface.
  11. 11. Appropriate lubrication of lingual and occlusalsurfaces is required before applying Triad® Gel.
  12. 12. Cure each layer of Triad® Gel
  13. 13. 2nd layer of gel extended over several of the adjacent teeth
  14. 14. Buccal viewillustrating gel added to just cover occlusal & lingual surface of teeth.
  15. 15. Fabrication insert removed leaving 5.3 mm guide sleeve
  16. 16. Buccal view5.3 mm wide guide sleeve
  17. 17. Axial view5.3 guide sleeve is centered over the 3/32” hole
  18. 18. 2.25 mm insert is used for initial 2 mm drill
  19. 19. IRT (insert removal tool) used to remove insert from guide sleeve.
  20. 20.  SURGICAL guide with 5.3 guide sleeve is placed over IRT Set on a firm surface and tapped with downward pressure to remove inserts.
  21. 21. 5.3 wide guide sleeve is used with appropriate inserts for drill sizes. Shown here with 4 mm insert
  22. 22. SURGICAL guide in place Appropriate inserts are used for each drill size2.0 mm insert, for 1.8 mm drill ■ 2.7 mm insert for 2.5 mm drill …etc. Completing the osteotomy with Astra 3.8 mm twist drill plus 5.0 mm conical drill used in 5.3 mm sleeve without an insert.
  23. 23. Peri-apical X-ray of SURGICAL guide alignment.
  24. 24. Final X-ray
  25. 25. Guide Right™Products shown in this case 3/32” drill 5.3 Wide Guide Sleeve Series of Inserts for 5.3 Guide Sleeve *next slide 5.3 Fabrication Insert (FABIN) 3 mm Guide Post Guide Sleeve Inserts for 5.3 Guide sleeve Insert Removal Tool (IRT) Petroleum Jelly Triad® Gel Recommended Kits: 4.5 / 5.3 Serial Guide Kit 1.800.314.0065 • www.deplaque.com
  26. 26. Serial INSERTS for 5.3 Guide Sleeves Guide Right™ Individual Insert Sizes Available 2.25 mm 2.6 mm 2.75 mm 3.0 mm 3.6 mm 4.0 mm 4.2 mm 4.6 mmOrder directly from > www.deplaque.com
  27. 27. Serial INSERTS for 4.5 Guide Sleeves Guide Right™ Fabrication Insert INSERTS FOR 4.5 Guide Sleeve FABIN Insert Removal ToolOrder directly from > www.deplaque.com
  28. 28. DéPlaqueGuide Right™ Surgical Guide System fabricate ▪ evaluate ▪ correct ▪ verify ▪ placeStart With Precision. Place With Confidence.™ 1.800.314.0065 • www.deplaque.com

×