The first step - accurate heating and cooling load calculations
SYED (HVAC ENGINEER)
1. CURRICULUM VITAE
Syed Nasir Ali,
HVAC Design Engineer,
B.E Mechanical,
E-Mail: syednasirali294@gmail.com
Phone: +91 9689767863
JOB APPLICATION
To
The HR Manager
Sub: Application for the post of “HVAC Design Engineer”.
Dear Sir,
With reference to the above subject, I avail this opportunity to introduce myself Mr. Syed Nasir Ali. I
am in a field where creative and logical thinking is must and I am confident that I can do justices to the
work with my talent and skills.
Being actively involved in the field of HVAC for last 3 years, presently working as a hvac design
engineer in Neil soft ltd in pune. I have gained wide experience, which has benefited me
professionally and broadened my creative and logical thinking in the HVAC field.
I am confident to Design & Draft the Mechanical works for commercial, Residential, Hospitalized &
industrial projects.
I’m enclosing here my Curriculum Vitae for your kind consideration of my candidature and hope that
I may get an opportunity to prove my worthiness.
Keeping in view of my qualification, knowledge and experience, I am confident that I can fulfill the
above-mentioned assignment perfectly and live up to your expectations.
Looking forward for a favorable response.
With best regards,
Syed nasir ali
Enclosure: Resume
2. RESUME
Work Experience:
Currently working as “HVAC design Engineer” in NEILSOFT LIMITED, Pune since 2nd,
March, 2015.
Worked as a “HVAC design engineer” in TAIBA CONSULTANT, Hyderabad from
JUNE, 2013 to March, 2015.
EDUCATION QUALIFICATION:
Degree University/Board College/School Year of passing
B.E. Mechanical Osmania University
Muffakkham Jah
College of Engineering
&
Technology, Hyderabad
2013
Diploma in Mech Engg S.B.T.E.T.‐Hyderabad
Q.Q.Govt. Polytechnic,
Hyderabad
2010
SSC Secondary board
Iqra Mission High
School
2007
Projects handled so far:
Project 1:
Client : US Clients
Description: Currently with Neilsoft in wrightsoft team I am handling Right Suite Software with an
intelligent software extensively used in USA for Heat Load, Equipment Selection, and Duct Design &
Layout & Air Terminal Devices Selection.
Checking the Markup’s as Received and raising doubts if any as per the V.E layout.
Pressure drop calculations for the blower selections with an excel sheet.
Project 2 :
Client : Seemac apartment ,India
Description: residential projects ( 12 floor building) , calculations of duct sizing as per geographical method
with excel sheets. Air conditioning has been done with 79,000 sft. Air distribution through no of FCU’s with
DX system.
Pressure drop calculations
Cooling coil load
Pump head calculations.
3. Project 3 :
Client : commercial building ,India
Description: commercial projects ( 5 floor building) , calculations of duct sizing ,blower selections. Air
conditioning has been done with 1,26,000 sft. Air distribution through no of FCU’s with DX system.
Project 4:
Client : Mayfair, India
Description: Hotel Project (6 floor Building), Calculation of duct sizing by using McQuay software,
Air conditioning has cooling with 95TR been done with 1, 00,000 sft. Air distribution through no of AHU’s,
FCU’s and Cassette unit & 6 chiller each.
Project 5:
Client : SEC Head quarter
Verification of the HVAC Air Balancing and Chilled water balancing as per IFC Layouts.
Verification of the Chilled water pipes sizes as per Ashrae Standard guidelines.
Verification of IFC duct and chilled water layout with Architectural, ID and Structural Layout.
HVAC ducting shop drawing
Hvac chilled water shop drawing
Necessary Sections.
Coordination for all Services.
Cross Checking of Schematics with floor plans.
Proposed necessary re-routing, re-sizing as required to resolve the clash or problems arise.
Job Responsibilities so far handled in above companies:
Concept / Preliminary Planning of the Mechanical Layout (i.e. HVAC & Plumbing)
Co-ordination with architectural, interiors and structural with all Mechanical services.
Co-Ordination with Electrical team for all required Electrical co-ordination in design, planning and shop
drawings.
Hands on experience on Heat loads on Hourly Analysis Program (HAP).
Hands on experience Manual Excel Heat loads as per Ashrae, Ishrae and Carrier method (E20-Form).
Selection of Air conditionings units like Package AC, AHU, FCU, Chillers, etc., with the help of ZAMIL
Software.
Chilled Water Pipe Sizing as per the guidance based in Ashrae and Carrier Charts.
Duct Sizing as per the guidance based in Ashrae Standards & Carrier Guide with the help of mac Quay
Duct Sizes.
Psychometric Equation and Analysis for the Cooling Coil Selection.
Air Terminal Devices Selection (Diffusers, Grills, Louvers) based on NC criteria as per Ashrae and NBC
ad selected from manufacturer catalogue Beta and Air master.
Hydraulic Calculations (i.e. Friction loss for pump head) for Chilled Water Pump Head Evaluation and
Selection.
Cooling Tower Selection.
Coil Selection based on the Air side temperatures and Chilled water temperatures.
Ventilation Calculations for Kitchen, Toilets and Car Parking Areas as per Ashare 62.1
External Static Pressure (ESP) or PRESSURE DROP Calculation for FCUs, AHUs and Fans.
4. PERSONAL DETAILS:
Name : Syed nasir ali
Father’s Name : Syed yousuf ali
Sex : Male
D.O.B : 23.11.1990
Marital Status : Unmarried
Nationality : Indian
Passport Number : Valid passport.
Language Known : English, Urdu, and Hindi
Permanent Address : jahanuma Hyderabad, India.
DECLARATION
I hereby declare that the above furnished details are true to the best of my knowledge and
belief.
Date :
Place : Hyderabad
Yours Sincerely
(Syed nasir ali)