The in.terface is a waterproof box that connects accessories like audio/video devices, keypads, and switches to Aeware spa systems. It comes in two configurations - one for audio/video control and one for auxiliary keypads. It is installed under the spa skirt in an upright position for watertightness. Connections to devices are made via color-coded terminals. Power is provided by connecting the in.terface to the spa pack; no power shutdown is needed except when using the auxiliary keypad version, which requires a spa pack reset after installation.
This document provides an overview of a training course on VERITAS Cluster Server for UNIX. It outlines the course curriculum, prerequisites, objectives, and exam objectives. It also describes the lab design that will be used in the course, including lab naming conventions and values. The document contains a table of contents and legends for topics that will be covered.
Here is a summary of the key points from the course overview:
- This course builds upon the fundamentals covered in the VERITAS Cluster Server Fundamentals course and focuses on implementing more complex cluster configurations with VCS.
- Participants will simulate real-world tasks of configuring advanced cluster features through hands-on labs that build upon each other.
- Core lessons cover the most common cluster implementations, while other lessons illustrate additional VCS capabilities through alternative configurations.
- The overall goal is to provide expertise in applying best practices for implementing any VCS design based on a provided high availability design that is used as an example throughout the course labs.
- Hands-on labs use a conceptual cluster design consisting of
I apologize, upon further review this document does not contain a clear document for me to summarize. The document appears to be an appendix that provides synopses of other labs and exercises. It does not contain a single coherent document for me to summarize.
This document provides training materials for configuring common applications in a VERITAS Cluster Server (VCS) environment. It includes conceptual overviews, configuration procedures, and lab exercises for clustering applications, databases, and NFS services. The labs allow students to practice setting up Application, Oracle, and NFS resources in a simulated VCS cluster. The document assumes knowledge of VCS fundamentals and includes varying levels of detail to accommodate different experience levels.
This document provides information about a hot tub control system including its model number, circuit board layout, connections for pumps, lights, blowers, and other components. It also describes dip switch and jumper settings that configure options like temperatures units, pump speeds, and other functions. Wiring diagrams are included for connecting an optional ozone generator at either 120V or 240V.
The document provides troubleshooting steps for an error condition where three flashing dots appear on the keypad display of an MSPA-MP spa pack. This typically indicates a problem with the pressure switch. The steps include checking for proper pump operation, continuity on the pressure switch, adjusting or replacing the pressure switch, and replacing the pressure switch cable or circuit board if needed. Diagrams are provided to illustrate pressure switch wiring and location of components.
If you encounter any problems or need assistance, contact HydroQuip's Technical Support staff by calling (909) 273-7575. HydroQuip is located at 13345 Estelle Street, Corona, CA 92879 and can also be reached via their website at www.hydroquip.com or by email at hq@hydroquip.com. The document provides contact information for HydroQuip's Technical Support staff and lists their address, phone number, fax number, website, and email.
This document is a technical service manual from Balboa Instruments that provides guidance on servicing Balboa control systems for spas. It includes sections on safety, required tools and components, system descriptions, troubleshooting wiring and voltage issues, testing circuit boards, changing circuit boards, filter settings, optional features, and information on specific Balboa circuit board models. The manual aims to help qualified technicians safely service Balboa control systems.
This document provides an overview of a training course on VERITAS Cluster Server for UNIX. It outlines the course curriculum, prerequisites, objectives, and exam objectives. It also describes the lab design that will be used in the course, including lab naming conventions and values. The document contains a table of contents and legends for topics that will be covered.
Here is a summary of the key points from the course overview:
- This course builds upon the fundamentals covered in the VERITAS Cluster Server Fundamentals course and focuses on implementing more complex cluster configurations with VCS.
- Participants will simulate real-world tasks of configuring advanced cluster features through hands-on labs that build upon each other.
- Core lessons cover the most common cluster implementations, while other lessons illustrate additional VCS capabilities through alternative configurations.
- The overall goal is to provide expertise in applying best practices for implementing any VCS design based on a provided high availability design that is used as an example throughout the course labs.
- Hands-on labs use a conceptual cluster design consisting of
I apologize, upon further review this document does not contain a clear document for me to summarize. The document appears to be an appendix that provides synopses of other labs and exercises. It does not contain a single coherent document for me to summarize.
This document provides training materials for configuring common applications in a VERITAS Cluster Server (VCS) environment. It includes conceptual overviews, configuration procedures, and lab exercises for clustering applications, databases, and NFS services. The labs allow students to practice setting up Application, Oracle, and NFS resources in a simulated VCS cluster. The document assumes knowledge of VCS fundamentals and includes varying levels of detail to accommodate different experience levels.
This document provides information about a hot tub control system including its model number, circuit board layout, connections for pumps, lights, blowers, and other components. It also describes dip switch and jumper settings that configure options like temperatures units, pump speeds, and other functions. Wiring diagrams are included for connecting an optional ozone generator at either 120V or 240V.
The document provides troubleshooting steps for an error condition where three flashing dots appear on the keypad display of an MSPA-MP spa pack. This typically indicates a problem with the pressure switch. The steps include checking for proper pump operation, continuity on the pressure switch, adjusting or replacing the pressure switch, and replacing the pressure switch cable or circuit board if needed. Diagrams are provided to illustrate pressure switch wiring and location of components.
If you encounter any problems or need assistance, contact HydroQuip's Technical Support staff by calling (909) 273-7575. HydroQuip is located at 13345 Estelle Street, Corona, CA 92879 and can also be reached via their website at www.hydroquip.com or by email at hq@hydroquip.com. The document provides contact information for HydroQuip's Technical Support staff and lists their address, phone number, fax number, website, and email.
This document is a technical service manual from Balboa Instruments that provides guidance on servicing Balboa control systems for spas. It includes sections on safety, required tools and components, system descriptions, troubleshooting wiring and voltage issues, testing circuit boards, changing circuit boards, filter settings, optional features, and information on specific Balboa circuit board models. The manual aims to help qualified technicians safely service Balboa control systems.
The document contains contact information for a company called MyPoolSpas.com that sells wholesale pool and spa parts, including their website address http://www.MyPoolSpas.com and phone number 920-925-3094. This information is repeated multiple times.
To control an iPod connected to the in.p3 dock using the in.k600 keypad, press the Mode key to select Audio mode, select CDC source, then use the multifunction keys to select tracks, change albums, repeat songs or play randomly while the Next key navigates menu pages.
The document contains contact information for a wholesale pool and spa parts business called MyPoolSpas.com, including their website address http://www.MyPoolSpas.com and phone number 920-925-3094, which is repeated multiple times.
The document provides installation instructions for the air.wav blower system. It includes warnings about proper installation and use. The specifications section lists the blower's dimensions, ratings, and airflow/pressure capabilities. Installation instructions specify fastening the blower brackets, using flexible piping, and making electrical connections according to codes. Connecting an optional keypad is also addressed.
The document provides installation and programming instructions for the Hayward 2100 Series pool and spa control system. It allows for monitoring and controlling up to 12 functions for pool system control and environment control from a main remote control unit. The system can control equipment such as pumps, lighting, heaters, and other devices. The document outlines electrical specifications, safety instructions, system components, installation of sensors and control panels, wiring, configuration, programming and troubleshooting.
The document provides instructions for operating a solid-state pool/spa control system, including how to use the power switch, check for proper voltage, and troubleshoot issues using the visual diagnostic system lights. Safety warnings are also given regarding risks like electric shock, hyperthermia, and proper water temperature. The system uses fuses to protect components and lights on the cord connections help diagnose if proper voltage is reaching each part.
The document describes the in.k455 audio wired remote control with display. It includes:
- An overview of the remote control and its features including large LCD display and 7 backlit keys.
- Descriptions of the function keys including on/off, source selection, track control keys.
- Instructions for installing the remote control, including a drilling template and using adhesive mounting.
- Diagrams showing connections of the remote control to either the in.xm spa system using an interface box, or directly to the in.tune player.
The keypad allows control of various spa functions including pumps, light, blower, waterfalls, economy mode, and standby mode. It has menus to start and stop each device and icons to display their operating status. Additional features include time display, progress bars, and programming options for spa and keypad settings.
The document provides an overview of the in.xm spa pack platform from Pentair. It highlights several innovative features of the in.xm including its waterproof enclosure, breakthrough connectors, kinetic heat monitoring system, dry-fire protection, board access prevention design, and intelligent water temperature algorithm. The in.xm is described as the safest and most reliable spa pack platform for manufacturers.
This document provides instructions for wiring the North American model of the in.xe spa control system. It describes stripping wires, connecting them to the appropriate terminals according to the label, securing the cable, and connecting the bonding conductor. Proper wiring of the electrical service box, GFCI, and in.xe terminal block is essential according to electrical codes.
Press Play/Pause to Press Intro to play the first 10 Repeat mode
pause playback. Press again to seconds of each track. Press
resume playback. Intro again to cancel Intro scan. Press Repeat to play the current track continuously. Press again to cancel Repeat mode.
Random mode Display information
Press Random to play tracks in Press Display to switch between:
random order. Press again to Track number - Elapsed time -
cancel Random mode. Remaining time - Clock (for 5 sec)
Note: Intro, Repeat and Random Note: When a CD is not inserted,
modes can be used together or "NO DISC" will be displayed
The document provides information about the in.k100 auxiliary keypad for controlling pool and spa equipment. It has keys to control pumps, lighting, and other functions. It is compact and waterproof for outdoor use. Installation involves using a template to cut an opening and mounting the keypad using an adhesive gasket. Connections to control systems are made using an in.link connector.
The document provides instructions for installing and using the in.power.210 DC power supply. It is designed for use in hot tub environments and provides dust and water splash protection. Key features include AC input that can be 120/240V and 50/60Hz, and a 12V DC output protected by a 5A fuse. Installation instructions specify mounting the unit above any flooding line on a horizontal or vertical surface, with at least 2 inches of clearance.
The document provides instructions for installing and using the in.k450 keypad for controlling in.xm and in.xe spa systems. It describes how to physically install the keypad, make connections, and use the various buttons to control spa functions like pumps, lights, temperature, and programming filter cycles or economy modes. Installation involves drilling holes and attaching the keypad using the provided template and adhesive gasket. Connection to the spa system is also described.
The document provides an overview and instructions for the in.k200 keypad for spa systems. The in.k200 is a compact, waterproof keypad that allows control of pumps, blowers, lights, and temperature for spas. It connects to the in.xe spa control system and is available in configurations to control 1-2 pumps and/or blowers. The instructions describe installing the keypad, connecting it to the in.xe system, and operating the buttons to control spa functions like pumps, lights and temperature.
This document provides specifications and installation instructions for the air.wav high performance blower. It includes warnings about safety, an overview of features, technical specifications, installation instructions, and information about connecting optional keypads. Safety precautions include proper installation, using ground fault circuit protection, keeping the blower out of reach of bathers, and ensuring proper ventilation. The blower produces 2.7 cubic meters per minute of airflow at 4.2 kPa of pressure from its 850W motor. Optional accessories include a silencer, heater, and electronic control boards.
This document provides specifications and installation instructions for the air.wav high performance blower. It includes warnings about safety, an overview of features, technical specifications, installation instructions, and information about connecting optional keypads. Safety precautions include proper installation, using ground fault circuit protection, keeping the blower out of reach of bathers, and ensuring proper ventilation. The blower produces 2.7 cubic meters per minute of airflow at 4.2 kPa of pressure from its 850W motor. Optional accessories include a silencer, heater, and electronic control boards.
The document provides information about the in.k400 keypad for controlling pool and spa equipment. It includes installation instructions for mounting the waterproof keypad using adhesive or brackets. Connection details are given for linking the keypad to an in.xm control unit. The functions of the keys are described for controlling pumps, lights, programs and settings. Specifications cover dimensions, temperature range, weight and standards compliance.
The document provides an overview of the in.zone ozone generator for spas and hot tubs. It includes warnings about safe installation and use. The summary describes how in.zone works using corona discharge to generate ozone, which is then injected into the spa water through tubing. Installation instructions are provided for installing the check valve and connecting the tubing to either an injection manifold or air control system. A suction test is recommended to ensure proper airflow before powering on in.zone. Specifications and connection options are also listed.
This document provides a template for installing spaside controls for pool and spa equipment. The template is only to be used with ECO-1, 2, 5, and 6 series controls and measures 2 5/8 inches by 2 5/8 inches with two 1 inch holes. Installers are directed to refer to the installation manual for details on installation.
1. Press the TONE button to access the tone selection mode.
2. Use the -/+ buttons to scroll through the available tones and select the one you want.
3. Play the keyboard to hear the selected tone.
This document provides installation instructions for an air series pool and spa control system. It covers considerations for installation location and plumbing, how to connect system components, electrical installation procedures, special considerations for lights, blowers, startup and pressure switch adjustment. Troubleshooting tips are also mentioned. The document includes diagrams of the control system and component connection colors. Installation must be done by a licensed electrician according to all applicable electrical codes.
The document contains contact information for a company called MyPoolSpas.com that sells wholesale pool and spa parts, including their website address http://www.MyPoolSpas.com and phone number 920-925-3094. This information is repeated multiple times.
To control an iPod connected to the in.p3 dock using the in.k600 keypad, press the Mode key to select Audio mode, select CDC source, then use the multifunction keys to select tracks, change albums, repeat songs or play randomly while the Next key navigates menu pages.
The document contains contact information for a wholesale pool and spa parts business called MyPoolSpas.com, including their website address http://www.MyPoolSpas.com and phone number 920-925-3094, which is repeated multiple times.
The document provides installation instructions for the air.wav blower system. It includes warnings about proper installation and use. The specifications section lists the blower's dimensions, ratings, and airflow/pressure capabilities. Installation instructions specify fastening the blower brackets, using flexible piping, and making electrical connections according to codes. Connecting an optional keypad is also addressed.
The document provides installation and programming instructions for the Hayward 2100 Series pool and spa control system. It allows for monitoring and controlling up to 12 functions for pool system control and environment control from a main remote control unit. The system can control equipment such as pumps, lighting, heaters, and other devices. The document outlines electrical specifications, safety instructions, system components, installation of sensors and control panels, wiring, configuration, programming and troubleshooting.
The document provides instructions for operating a solid-state pool/spa control system, including how to use the power switch, check for proper voltage, and troubleshoot issues using the visual diagnostic system lights. Safety warnings are also given regarding risks like electric shock, hyperthermia, and proper water temperature. The system uses fuses to protect components and lights on the cord connections help diagnose if proper voltage is reaching each part.
The document describes the in.k455 audio wired remote control with display. It includes:
- An overview of the remote control and its features including large LCD display and 7 backlit keys.
- Descriptions of the function keys including on/off, source selection, track control keys.
- Instructions for installing the remote control, including a drilling template and using adhesive mounting.
- Diagrams showing connections of the remote control to either the in.xm spa system using an interface box, or directly to the in.tune player.
The keypad allows control of various spa functions including pumps, light, blower, waterfalls, economy mode, and standby mode. It has menus to start and stop each device and icons to display their operating status. Additional features include time display, progress bars, and programming options for spa and keypad settings.
The document provides an overview of the in.xm spa pack platform from Pentair. It highlights several innovative features of the in.xm including its waterproof enclosure, breakthrough connectors, kinetic heat monitoring system, dry-fire protection, board access prevention design, and intelligent water temperature algorithm. The in.xm is described as the safest and most reliable spa pack platform for manufacturers.
This document provides instructions for wiring the North American model of the in.xe spa control system. It describes stripping wires, connecting them to the appropriate terminals according to the label, securing the cable, and connecting the bonding conductor. Proper wiring of the electrical service box, GFCI, and in.xe terminal block is essential according to electrical codes.
Press Play/Pause to Press Intro to play the first 10 Repeat mode
pause playback. Press again to seconds of each track. Press
resume playback. Intro again to cancel Intro scan. Press Repeat to play the current track continuously. Press again to cancel Repeat mode.
Random mode Display information
Press Random to play tracks in Press Display to switch between:
random order. Press again to Track number - Elapsed time -
cancel Random mode. Remaining time - Clock (for 5 sec)
Note: Intro, Repeat and Random Note: When a CD is not inserted,
modes can be used together or "NO DISC" will be displayed
The document provides information about the in.k100 auxiliary keypad for controlling pool and spa equipment. It has keys to control pumps, lighting, and other functions. It is compact and waterproof for outdoor use. Installation involves using a template to cut an opening and mounting the keypad using an adhesive gasket. Connections to control systems are made using an in.link connector.
The document provides instructions for installing and using the in.power.210 DC power supply. It is designed for use in hot tub environments and provides dust and water splash protection. Key features include AC input that can be 120/240V and 50/60Hz, and a 12V DC output protected by a 5A fuse. Installation instructions specify mounting the unit above any flooding line on a horizontal or vertical surface, with at least 2 inches of clearance.
The document provides instructions for installing and using the in.k450 keypad for controlling in.xm and in.xe spa systems. It describes how to physically install the keypad, make connections, and use the various buttons to control spa functions like pumps, lights, temperature, and programming filter cycles or economy modes. Installation involves drilling holes and attaching the keypad using the provided template and adhesive gasket. Connection to the spa system is also described.
The document provides an overview and instructions for the in.k200 keypad for spa systems. The in.k200 is a compact, waterproof keypad that allows control of pumps, blowers, lights, and temperature for spas. It connects to the in.xe spa control system and is available in configurations to control 1-2 pumps and/or blowers. The instructions describe installing the keypad, connecting it to the in.xe system, and operating the buttons to control spa functions like pumps, lights and temperature.
This document provides specifications and installation instructions for the air.wav high performance blower. It includes warnings about safety, an overview of features, technical specifications, installation instructions, and information about connecting optional keypads. Safety precautions include proper installation, using ground fault circuit protection, keeping the blower out of reach of bathers, and ensuring proper ventilation. The blower produces 2.7 cubic meters per minute of airflow at 4.2 kPa of pressure from its 850W motor. Optional accessories include a silencer, heater, and electronic control boards.
This document provides specifications and installation instructions for the air.wav high performance blower. It includes warnings about safety, an overview of features, technical specifications, installation instructions, and information about connecting optional keypads. Safety precautions include proper installation, using ground fault circuit protection, keeping the blower out of reach of bathers, and ensuring proper ventilation. The blower produces 2.7 cubic meters per minute of airflow at 4.2 kPa of pressure from its 850W motor. Optional accessories include a silencer, heater, and electronic control boards.
The document provides information about the in.k400 keypad for controlling pool and spa equipment. It includes installation instructions for mounting the waterproof keypad using adhesive or brackets. Connection details are given for linking the keypad to an in.xm control unit. The functions of the keys are described for controlling pumps, lights, programs and settings. Specifications cover dimensions, temperature range, weight and standards compliance.
The document provides an overview of the in.zone ozone generator for spas and hot tubs. It includes warnings about safe installation and use. The summary describes how in.zone works using corona discharge to generate ozone, which is then injected into the spa water through tubing. Installation instructions are provided for installing the check valve and connecting the tubing to either an injection manifold or air control system. A suction test is recommended to ensure proper airflow before powering on in.zone. Specifications and connection options are also listed.
This document provides a template for installing spaside controls for pool and spa equipment. The template is only to be used with ECO-1, 2, 5, and 6 series controls and measures 2 5/8 inches by 2 5/8 inches with two 1 inch holes. Installers are directed to refer to the installation manual for details on installation.
1. Press the TONE button to access the tone selection mode.
2. Use the -/+ buttons to scroll through the available tones and select the one you want.
3. Play the keyboard to hear the selected tone.
This document provides installation instructions for an air series pool and spa control system. It covers considerations for installation location and plumbing, how to connect system components, electrical installation procedures, special considerations for lights, blowers, startup and pressure switch adjustment. Troubleshooting tips are also mentioned. The document includes diagrams of the control system and component connection colors. Installation must be done by a licensed electrician according to all applicable electrical codes.
2012 arctic cat 350 atv service repair manualjksnmdms
This Arctic Cat service manual provides information to aid technicians in servicing 2012 Arctic Cat 350 ATV models. The manual is divided into sections covering specific components and systems, and includes procedures for disassembly, inspection, and reassembly. Safety notices and torque specifications are also included to ensure repairs are performed correctly. The manual aims to build technician efficiency and consumer confidence through familiarizing technicians with construction and servicing of components.
2012 ARCTIC CAT 350 ATV Service Repair Manual.pdfhuanwrj0196
This Arctic Cat service manual provides information to aid technicians in servicing and repairing the 2012 Arctic Cat 350 ATV. The manual is divided into sections covering specific components and systems, and provides service procedures, disassembly/assembly instructions, and troubleshooting information. Technicians should become familiar with each component by carefully studying the manual, which will help them work more efficiently and build consumer confidence. The manual identifies important information using warning, caution, and note symbols and directives.
Kawasaki 80 z7 wheel loader service repair manual (serial no. 80c6 3001 and up)fjsjjekdkme
The document provides layout diagrams and specifications for the components of a Hitachi 80Z7 wheel loader, including the location of the engine, hydraulic pumps, electrical components, radiator assembly, cab, front and rear axles, and other major systems. Specification data is given for the loader's dimensions, bucket capacity, operating weight, tipping load, and engine details. The diagrams show the positioning of the main mechanical and electrical components.
Kawasaki 80 z7 wheel loader service repair manual (serial no. 80c6 3001 and up)f98soeodidkdk
This document contains shop manuals for the Hitachi 80Z7 wheel loader, including sections on general information, systems, component operation, operational performance tests, and troubleshooting. It provides technical specifications, component layouts, operating principles, maintenance standards, and repair procedures for technicians working on the 80Z7 which is powered by a Cummins QSB6.7 engine. The manuals use metric units and include electrical diagrams, hydraulic schematics, and safety and conversion information.
This document provides instructions for adjusting various settings on a spa control panel, including temperature unit (F or C), time of day, economy mode start time and duration, panel lock, and descriptions of default settings and modes like economy mode and freeze protection. Settings are adjusted using the program, list, enter and up/down arrow keys, and confirmed with enter. Error codes are displayed as flashing dots and require servicing.
The document provides instructions for operating various functions of a spa or hot tub. It describes the economy mode which maintains water temperature 20°F below the set point. It also describes the freeze protection mode which activates the pump and heater if water drops below certain temperatures. Default settings are described such as filtration cycles running for 1 hour every 24 hours with water at 95°F. Instructions are provided for operating pumps, blowers, lights and setting the temperature. Error codes and troubleshooting tips are also summarized.
This document provides installation and operation instructions for a PS-9704 series pool/spa control system. It includes guidelines for installing remote heaters, making electrical and wet connections, programming filtration settings, and troubleshooting. Safety precautions are outlined, and a wiring diagram and parts list are provided.
The document provides installation and operation instructions for a Platinum Series pool and spa control system. It includes details on installing remote heaters, electrical connections, temperature sensors, equipment connections, and programming filtration settings. Safety instructions are provided at the beginning regarding proper installation and use of the system.
The document provides installation instructions for PS-6502 & PS-6503 Platinum Series pool and spa control systems. It describes how to install the heater in different locations including on the bottom, back, or top of the control box using adjustable clamps or slide brackets. The instructions also cover electrical installation, temperature sensor placement, equipment connections, and programming filtration settings. Additional sections provide details on optional equipment, operational considerations, troubleshooting, and warranty information.
The document provides information on the default system operation, freeze protection modes, high temperature error handling, filtration cycles, pump and blower controls, light controls, temperature setting, and error identification for a spa or pool system. When power is applied, the system will initiate a default 24-hour filtration cycle at 95°F. It describes two modes of freeze protection below 59°F and 49°F and will suspend filtration if temperatures exceed 115°F or reach errors.
The document provides instructions for operating and programming a spa, including:
- If the water temperature exceeds 115°F, the heater will turn off, and above 122°F all outputs will disable until cooled.
- The filtration cycle can be programmed to run 1, 2, or 3 times daily for 60, 120, 180, or 480 minutes each cycle.
- By default, the spa will filter for 1 hour every 24 hours, maintaining the temperature at 95°F.
- Instructions are provided for operating the pump, accessory, light, and adjusting the temperature settings.
- The system enters a freeze protection mode if the temperature drops below 59°F by turning the pump on periodically.
The document provides instructions for operating and programming a spa control system. It describes how the system handles high temperatures, allows setting filter cycles for 1-3 times daily and durations of 60-180 minutes, and will default to a 24-hour filter cycle at 95°F if power is lost. It also explains how to operate the pump, light, and change the temperature setting, and describes freeze protection and error identification features.
This document summarizes the revision history of PCB part number 33-0024-Rx from the initial R0 revision in January 1999 through the current R6 revision. It describes the changes made at each revision level such as PCB layout changes, software changes, additions of memory and removal of features. It also provides information to help identify the correct wiring diagram for a given revision level.
This document provides instructions for an Eco 1 timed filtration system. It states to press and hold the light button to change the duration of filtration, and to press and hold the pump button to change the number of times filtration will occur. It also provides contact information for My Pool and Spas, a wholesale pool and spa parts supplier.
The document provides instructions for setting various operating parameters of a pool or spa control system including time, filtration start/duration, temperature display units, panel lock, economy mode, freeze protection, and error conditions. It describes pressing the program key to access each setting and using up/down arrows to adjust before pressing program to save. It also lists default settings if power is lost.
The changes include:
- Two programmable filtration cycles, one for AM and one for PM.
- A new "Smart Summer Mode" that operates pumps and chlorinators during cooler times when temperatures exceed a threshold.
- Optional programming via Palm Pilot or keypad.
- New auxiliary circuit and circulation pump options.
- Updated owner's manuals to reflect changes.
This document provides contact information for a wholesale pool and spa parts business called MyPoolSpas.com. It lists their phone number as 920-925-3094. The business sells wholesale pool and spa parts.
This document provides contact information for a company called MyPoolSpas.com Spa Parts Wholesale Pool. They sell pool and spa parts and can be reached by calling 920-925-3094. The document lists the name of the company and their phone number.
The document provides instructions for programming various settings on an HT-2 / 9600 Series spa control system, including time of day, filtration cycle start time and duration, economy mode start time and duration, temperature units (Fahrenheit or Celsius), and a spa-side lock feature. It also describes low level programming options that can be changed by positioning jumpers on the system board, including pump, blower, light, ozone, fiber optics, clock, current, circulation pump, and sensor calibration settings.
The document discusses four jumpers on a system board that can be positioned to change parameters of an equipment system. Jumper 1 sets either a high or low current limit. Jumper 2 selects whether temperature is displayed in Fahrenheit or Celsius. Jumpers 3 and 4 determine if the pumps run as single or two speed pumps. Positioning the jumpers allows customizing the system's operation based on electrical specifications and pump configuration.
This document provides instructions for operating an infrared remote control for a pool or spa. It includes:
1. A key chart explaining the functions of each button on the remote control.
2. Instructions for programming the remote to control up to three home entertainment or automation devices by entering their unique four-digit codes.
3. Procedures for replacing batteries, searching for codes if a device is not responding, checking stored codes, and putting the remote into learning mode to add new functions from an original remote control.
The document provides instructions for programming a Palm Pilot PDA to communicate with and adjust the low-level programming of Hydro-Quip control systems. The PDA must have the Serve-Soft 2 software installed and unlocked using the username "Hydro-Quip" and password "Hq92u1". An ADIR-1 cartridge is used to connect the PDA to the control system. Low-level parameters can then be viewed and modified on the PDA screen by tapping selections. Additional features like current states, troubleshooting, and documentation can also be accessed.
1. ����������
������������������������
��������
����������������������
�����������������
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
2. in.terface table of contents
Table of contents
overview ..........................................................................................3
installation .......................................................................................6
connections
- audio/video in.terface .................................................... 8
- aux. keypad in.terface ..................................................... 9
powering the unit ...........................................................................11
specifications ..................................................................................12
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
1
3. in.terface
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
2
4. in.terface overview
in.terface
Versatile connecting box
In.terface is a waterproof universal box used to connect various
accessories to Aeware spa systems.
UL, CSA, CE approved, in.terface is available in 2 configurations:
• Audio/video in.terface is used to control Aeware's in.tune
receiver/cd player or in.pix dvd/cd player from in.k600 series of
menu-driven interface spa keypads.
• Auxiliary keypad in.terface is used to connect auxiliary keypads
(3 different versions available).
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
3
5. overview in.terface
Audio/video in.terface
"AU" enclosure "CO" enclosure keyings
keyings
Fastening bracket
To spa pack
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
4
6. in.terface overview
Aux. keypad in.terface
"C" enclosure keyings "AC" enclosure keyings
Fastening bracket
To spa pack
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
5
7. installation in.terface
The unit must be installed under the spa skirt, in the upright
position to ensure watertightness.
We recommend that you install the unit with #8 PAN-head screws.
See the illustration above.
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
6
8. in.terface connections
Audio/video in.terface
in.tune (or in.pix)
Blue "AU" enclosure keyings
are used to connect the audio/ in.k455
video device (in.tune or in.pix)
and a wired remote (in.k455 or to DJS, SpaWatch, in.pocket
in.k155) to the in.terface. or
Optional purple "CO"
enclosure keyings are used to
connect DJS-1, SpaWatch or in.k155
Pocket-tek ADIR II cartridge
(in.pocket).
Connect the in.terface to the
Aeware spa pack (in.xm) purple
"CO" connector.
in.xm
(or any Aeware spa pack)
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
7
9. connections in.terface
Auxiliary keypad in.terface
Connection of the in.terface to
the Aeware spa pack (in.xm) is
done through the orange "C"
connector for all three versions.
In.k100/in.k400/
Streamlined interface
version of in.k600
If you use the in.k100, in.k400
or streamlined interface version
of the in.k600, you need to
connect the keypads in the
orange "C" enclosure keyings of
the in.terface.
Note that only one type of
single-configuration keypad
can be used. Keypad on the in.xm
first connector (left) determines (or any Aeware spa pack)
keypad's type.
You can connect up to
5 keypads to the in.terface.
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
8
10. in.terface connections
Auxiliary keypad in.terface (Con't)
Single switch P1 P2 P3 P4
If you use single switches, you
need to connect them in the
white "AC" enclosure keyings of P5
the in.terface.
Connector position determines
switch's functionality.
Customized functionality is
possible. Contact us for more
details.
You can connect up to 5 single
switches to the in.terface (k-29
keypads, etc.).
in.xm
(or any Aeware spa pack)
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
9
11. connections in.terface
Auxiliary keypad in.terface (Con't)
P1
Dry contact switch Light
P1 P2 P3
If you use dry contact switches,
you need to connect them
in the white "AC" enclosure Light
keyings.
Up to 2 loads per connector is
possible for a maximum of
4 different loads.
Wires of cables determine
switch's functionality.
in.xm
(or any Aeware spa pack)
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
10
12. in.terface powering the unit
Powering the in.terface
Simply connect the in.terface to the Aeware spa pack (in.xm).
See the illustration opposite.
You do not need to turn off the power before connecting the
in.terface to the Aeware spa pack (in.xm). But if you use the
auxiliary keypad in.terface, you will need to reset the Aeware spa
pack (in.xm) after completion of the installation.
Note:
Before powering the Aeware spa pack (in.xm), make sure all
accessories are linked to the bonding connector and connected to
the spa pack. Make sure also that the spa pack door is closed.
Then turn on the breaker.
For more details, please refer to the Aeware spa pack (in.xm)
techbook.
Audio/video in.terface connection shown above
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
11
13. specifications in.terface
Environmental ratings:
Humidity: Up to 85% non condensing
operating temp.: -25˚C to +60˚C
Storage temp.: -30˚C to +85˚C
Standards:
UL 1563 Fifth Ed.
CSA No. 22.2 - 218.1-M89
IEC: 60335-2-60-2.2002
EN: 60335-2-60: 2003
Specifications and design are subject to change without prior notice.
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
12
14. Advanced electronics! Water resistance!
Gecko Alliance
450 des Canetons, Quebec City (QC) G2E 5W6 Canada, 1.800.78.GECKO
9225 Stellar Court, Corona, CA 92883 USA, 951.667.2000
9919-100722 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
Rev. 05/07 www.geckoalliance.com