Page 1 of 2
SALIENT FEATURES
DESCRIPTION
TECHNICAL SPECIFICATIONS
ELECTRONET
PH/ORP TRANSMITTER
PH-100S
CAT/PH-100S-R1
· On-line measurement. 2 wire system.
· 4-20 mA DC output. Auto/Manual temperature compensation.
· On-Line indication through LCD display.
· Simple operating interface with basic pictographs.
· Easy installation with pre assembled empty enclosure & plug in
terminals.
· Protection Class IP-65
· Software calibration with buffer solution.
Electronet series PH-100S are PH / ORP transmitters used for various industrial applications. It can accept
input from pH / ORP electrode & pH / ORP signal is transmitted in the form of electrical 4 - 20 mA signal. The
on-line pH / ORP indication is provided through LCD. Span/Zero adjustments are easily accessibly. These
transmitters are suitable for any make of electrode.
Type of Input : From pH/ORP Electrode (Compatible to any make Electrode)
Type of Output : 4-20 mA DC, 2 wire Isolated
Display : 8 x 1 LCD/COG Graphics LCD
Calibration Range : 0 to 14 pH /1000 mV
Calibration Method : 2 Point buffer (For pH Only)
Temperature Compensation : Auto / Manual through RTD, Pt 100 sensor for 0-125 °C
Accuracy : ± 0.05 pH / ± 3mV
Isolation : 1.4 KV between Input, Output & Power Supply
Process Connection : 1) Through BNC connector
2) Through Terminals
Power Supply : 24 V DC, External
Power Consumption : < 50 mW
Repeatability : ± 0.05% of span, at 25 °C
Sensitivity : ± 0.02 pH
Stability : 0.02 pH per 24 Hours, non- cumulative
Response Time : < 1000 ms
Temperature Coefficient : ± 0.05% per C
Temperature Drift : ± 0.02% of span per °C (zero & span) at 25 °C
Dimensions : 135 (H) x 182 (W) including cable gland x 200 (D) in mm approx.
Electrical Connections : 3/4” ET
Mounting : 2” Pipe Mounting
Weight : 0.5 kg
Operating Conditions : Temperature 0 to 55 °C / Humidity 5 to 95% non condensing
Housing : Cast aluminium with epoxy coating NEMA 4X (IP-65)
Digital Communication : HART
ACCESSORIES (Optional)
Temperature Compensation Sensor : RTD, Pt 100 (0 - 125 °C)
Flow Through Assembly : SS / PP
Electrode Cleaning System : SS / PP
NK Instruments Pvt. Ltd.B-501/504, 5th floor, Raunak Arcade, Near THC Hospital, Gokhale Road, Naupada,
Thane(W) 400602. Maharashtra INDIA Telefax Nos.: 91-22-25301330 / 31 / 32
E-Mail: sales@nkinstruments.com Web: http://www.nkinstruments.com
Skype: nitinkelkarskype Gtalk: nkinstruments2006
Authorised Dealer
ORDERING INFORMATION
*Accuracy defined at lab conditions.
*Due to our continuous product revisions, Design, Specifications and Model Number are subject to change without notice.
Page 2 of 2CAT/PH-100S-R1
SERIES
Temperature
CompensationEnclosure
01 RTD
08 Other
BA 01 02pH-100
Output
01 4-20mA
02 4-20mA
with HART
C 02
DIMENSIONAL & MOUNTING DETAILS
130mm
147 mm
HTIGT WP HE EE
N
K
C
–
I
E
R
R
C
E
U
H
IT
P
A
S
L
O
IV
M
E
T
-
A
-IE NVI ES XOLP
007.00
pH
104mm
155mm
pH-100S
2” PIPE
`U` CLAMP FOR
PIPE MOUNTING
HTIGT WP HE EE
N
K
C
–
I
E
R
R
C
E
U
H
IT
P
A
S
L
O
IV
M
E
T
-
A
-IE NVI ES XOLP
007.00
pH
pH-100S
WALL MOUNT PIPE MOUNT
Input Device
pH Input
LOOP DIAGRAM
4-20mA
Output
Sensor
HART Communicator
Sensor
Signal
AnalogOutput
Output Device
Transmitter Electronics
Module
Microprocessor
Digital PV
POWER SUPPLY Vs LOAD GRAPH
16 18 24 30 36 42
0
250
500
750
1000
1250
1500
With HART Communication
Without HART Communication
500 ohms
1200 ohms
Power Supply Load limitation
Load,ohms
01 Aluminum
Dia cast
02 SS316

PH/ORP Transmitter PH-100S

  • 1.
    Page 1 of2 SALIENT FEATURES DESCRIPTION TECHNICAL SPECIFICATIONS ELECTRONET PH/ORP TRANSMITTER PH-100S CAT/PH-100S-R1 · On-line measurement. 2 wire system. · 4-20 mA DC output. Auto/Manual temperature compensation. · On-Line indication through LCD display. · Simple operating interface with basic pictographs. · Easy installation with pre assembled empty enclosure & plug in terminals. · Protection Class IP-65 · Software calibration with buffer solution. Electronet series PH-100S are PH / ORP transmitters used for various industrial applications. It can accept input from pH / ORP electrode & pH / ORP signal is transmitted in the form of electrical 4 - 20 mA signal. The on-line pH / ORP indication is provided through LCD. Span/Zero adjustments are easily accessibly. These transmitters are suitable for any make of electrode. Type of Input : From pH/ORP Electrode (Compatible to any make Electrode) Type of Output : 4-20 mA DC, 2 wire Isolated Display : 8 x 1 LCD/COG Graphics LCD Calibration Range : 0 to 14 pH /1000 mV Calibration Method : 2 Point buffer (For pH Only) Temperature Compensation : Auto / Manual through RTD, Pt 100 sensor for 0-125 °C Accuracy : ± 0.05 pH / ± 3mV Isolation : 1.4 KV between Input, Output & Power Supply Process Connection : 1) Through BNC connector 2) Through Terminals Power Supply : 24 V DC, External Power Consumption : < 50 mW Repeatability : ± 0.05% of span, at 25 °C Sensitivity : ± 0.02 pH Stability : 0.02 pH per 24 Hours, non- cumulative Response Time : < 1000 ms Temperature Coefficient : ± 0.05% per C Temperature Drift : ± 0.02% of span per °C (zero & span) at 25 °C Dimensions : 135 (H) x 182 (W) including cable gland x 200 (D) in mm approx. Electrical Connections : 3/4” ET Mounting : 2” Pipe Mounting Weight : 0.5 kg Operating Conditions : Temperature 0 to 55 °C / Humidity 5 to 95% non condensing Housing : Cast aluminium with epoxy coating NEMA 4X (IP-65) Digital Communication : HART ACCESSORIES (Optional) Temperature Compensation Sensor : RTD, Pt 100 (0 - 125 °C) Flow Through Assembly : SS / PP Electrode Cleaning System : SS / PP
  • 2.
    NK Instruments Pvt.Ltd.B-501/504, 5th floor, Raunak Arcade, Near THC Hospital, Gokhale Road, Naupada, Thane(W) 400602. Maharashtra INDIA Telefax Nos.: 91-22-25301330 / 31 / 32 E-Mail: sales@nkinstruments.com Web: http://www.nkinstruments.com Skype: nitinkelkarskype Gtalk: nkinstruments2006 Authorised Dealer ORDERING INFORMATION *Accuracy defined at lab conditions. *Due to our continuous product revisions, Design, Specifications and Model Number are subject to change without notice. Page 2 of 2CAT/PH-100S-R1 SERIES Temperature CompensationEnclosure 01 RTD 08 Other BA 01 02pH-100 Output 01 4-20mA 02 4-20mA with HART C 02 DIMENSIONAL & MOUNTING DETAILS 130mm 147 mm HTIGT WP HE EE N K C – I E R R C E U H IT P A S L O IV M E T - A -IE NVI ES XOLP 007.00 pH 104mm 155mm pH-100S 2” PIPE `U` CLAMP FOR PIPE MOUNTING HTIGT WP HE EE N K C – I E R R C E U H IT P A S L O IV M E T - A -IE NVI ES XOLP 007.00 pH pH-100S WALL MOUNT PIPE MOUNT Input Device pH Input LOOP DIAGRAM 4-20mA Output Sensor HART Communicator Sensor Signal AnalogOutput Output Device Transmitter Electronics Module Microprocessor Digital PV POWER SUPPLY Vs LOAD GRAPH 16 18 24 30 36 42 0 250 500 750 1000 1250 1500 With HART Communication Without HART Communication 500 ohms 1200 ohms Power Supply Load limitation Load,ohms 01 Aluminum Dia cast 02 SS316