The HART (Highway Addressable Remote Transducer) is a master/slave communication protocol which provides for up to two masters. The secondary master can be used to monitor/control the information of the HART bus. HART can be used in various modes such as point-to-point or multi-drop for communicating information to/from smart field instruments and central control or monitoring systems.
Learn more: http://www.icpdas-usa.com/hart_gateways.html?r=slideshare
KYL-300M, the high speed data radio is designed to be low cost and high performance radio modem. The new design makes the modem more flexible for different application in various configurations. Basically, this type of modem is SMART enough to be customized to best meet end user’s requirements. Users don’t have to pay the features that never be used in their projects. The following lists its general functionalities of this series.
Specifications of KYL-300M
* Power output: DC 5V (customize);
* RF power: 2W(customize);
* RF Effective Rate: 1200/2400/4800/9600/19200bps
* Interface baud rate: 1200/2400/4800/9600/19200bps optional
* Frequency Band: 433MHz,450MHz,470MHz or ISM others
* Interface: standard RS-232/RS-485 or USB and TTL
* Communication Mode: Half-duplex
* Offering a transparent data interface, it is suitable for any standard or non-standard user protocols
* Channel: 8(Default),16/32(customized)
* Receive current: <30ma><1><20uA;
* RF Line-of-sight Range: 5km(BER=10-3(at)9600bps); 7km(BER=10-3(at)1200bps)
* Size: 80mm*45mm*19mm (without antenna port).
Specifications of KYL-200L
* Power output: DC 5V (customize);
* RF power: ≤500mW(customized 500mW~1W);
* RF Effective Rate: 1200/2400/4800/9600/19200bps
* Interface baud rate: 1200/2400/4800/9600/19200bps optional
* Frequency Band: 433 MHz, 450MHz,470MHz, 868MHz, 915MHz or ISM others
* Interface: standard RS-232/RS-485/TTL
* Communication Mode: Half-duplex
* Offering a transparent data interface, it is suitable for any standard or non-standard user protocols
* Channel: 8(Default),16/32(customized)
* Receive current: <28ma><400ma><20ua>2km(BER=10-5(at)9600bps); >3km(BER=10-5(at)1200bps)
* Size: 53x38x10mm (without antenna port).
“HART” is an acronym for Highway Addressable Remote Transducer. The HART Protocol makes use of the Bell 202 Frequency Shift Keying (FSK) standard to superimpose digital communication signals at a low level on top of the 4-20mA.
The HART (Highway Addressable Remote Transducer) is a master/slave communication protocol which provides for up to two masters. The secondary master can be used to monitor/control the information of the HART bus. HART can be used in various modes such as point-to-point or multi-drop for communicating information to/from smart field instruments and central control or monitoring systems.
Learn more: http://www.icpdas-usa.com/hart_gateways.html?r=slideshare
KYL-300M, the high speed data radio is designed to be low cost and high performance radio modem. The new design makes the modem more flexible for different application in various configurations. Basically, this type of modem is SMART enough to be customized to best meet end user’s requirements. Users don’t have to pay the features that never be used in their projects. The following lists its general functionalities of this series.
Specifications of KYL-300M
* Power output: DC 5V (customize);
* RF power: 2W(customize);
* RF Effective Rate: 1200/2400/4800/9600/19200bps
* Interface baud rate: 1200/2400/4800/9600/19200bps optional
* Frequency Band: 433MHz,450MHz,470MHz or ISM others
* Interface: standard RS-232/RS-485 or USB and TTL
* Communication Mode: Half-duplex
* Offering a transparent data interface, it is suitable for any standard or non-standard user protocols
* Channel: 8(Default),16/32(customized)
* Receive current: <30ma><1><20uA;
* RF Line-of-sight Range: 5km(BER=10-3(at)9600bps); 7km(BER=10-3(at)1200bps)
* Size: 80mm*45mm*19mm (without antenna port).
Specifications of KYL-200L
* Power output: DC 5V (customize);
* RF power: ≤500mW(customized 500mW~1W);
* RF Effective Rate: 1200/2400/4800/9600/19200bps
* Interface baud rate: 1200/2400/4800/9600/19200bps optional
* Frequency Band: 433 MHz, 450MHz,470MHz, 868MHz, 915MHz or ISM others
* Interface: standard RS-232/RS-485/TTL
* Communication Mode: Half-duplex
* Offering a transparent data interface, it is suitable for any standard or non-standard user protocols
* Channel: 8(Default),16/32(customized)
* Receive current: <28ma><400ma><20ua>2km(BER=10-5(at)9600bps); >3km(BER=10-5(at)1200bps)
* Size: 53x38x10mm (without antenna port).
“HART” is an acronym for Highway Addressable Remote Transducer. The HART Protocol makes use of the Bell 202 Frequency Shift Keying (FSK) standard to superimpose digital communication signals at a low level on top of the 4-20mA.
Akoya By Damac villas apartment In Dubai Offers The Drive at AKOYA , Trump International Golf Club Dubai , Villas on the golf course , Villas in the park , Golf residences , Park residences , Masterpieces , Trump PRVT , DAMAC Villas by Paramount Hotels & Resorts , Fendi-styled villas More visit http://dubaiproperties.org.in/akoya-by-damac/
Estrategias para el aprendizaje significativoYoly63
II Comprensión y Composición de Texto
La Enseñanza de estrategias de comprensión de lectura.
Esta basados en estrategias técnicas específicos.
Otras metodologías de Mateo y Alonso son las siguientes:
La enseñanza se basa en la práctica interactiva y conjunta de las estrategias creadas entre un enseñante-experto y una aprendiz-novato.
La instrucción se fundamenta principalmente en el papel mediador de un modelo (alguien quien sabe más) quien modela el cómo usar las estrategias.
El enseñante es un guía que orienta y crea las condiciones y el contexto apropiados para el aprendizaje de las estrategias.
La estrategias general de los programas está basada en el traspaso del control del enseñante al aprendiz a través de situaciones de andamiaje y práctica guiada.
Metodología de Vigotsky
El origen social de los procesos psicológicos superiores (los procesos psicológicos superiores aparecen primero en el plano de los interpersonales después son internalizados y apropiados por el aprendizaje.
La noción de ZDP (“la enseñanza reciproca fue diseñada para proveer una ZDP en la cual los estudiantes, con la ayuda de los maestros y de compañeros mas avanzados, se toman una responsabilidad cada vez mayor en la realización de una actividad.
Los procesos psicológicos son adquiridos en una actividad contextuadas y holísticas (las estrategias no son aprendidas fuera del contexto de la lectura funcional o significativa).
Estrategias de Brown y Palincsar
Resumir (autorreversión)
Construcción de preguntas (autoevaluación)
Elaborar predicciones (activación del conocimiento previo)
Clarificar (detección de problemas en la compresión).
American Fibertek MRX-8423C-SL User ManualJMAC Supply
Buy the American Fibertek MRX-8423C-SL at JMAC Supply.
https://www.jmac.com/American_Fibertek_MRX_8423C_SL_p/american-fibertek-mrx-8423c-sl.htm?=slideshare
This PPT explains about TV Remote Operated Domestic Appliances Control.
Edgefxkits.com has a wide range of electronic projects ideas that are primarily helpful for ECE, EEE and EIE students and the ideas can be applied for real life purposes as well.
http://www.edgefxkits.com/
Visit our page to get more ideas on popular electronic projects developed by professionals.
Edgefx provides free verified electronic projects kits around the world with abstracts, circuit diagrams, and free electronic software. We provide guidance manual for Do It Yourself Kits (DIY) with the modules at best price along with free shipping.
Kubernetes & AI - Beauty and the Beast !?! @KCD Istanbul 2024Tobias Schneck
As AI technology is pushing into IT I was wondering myself, as an “infrastructure container kubernetes guy”, how get this fancy AI technology get managed from an infrastructure operational view? Is it possible to apply our lovely cloud native principals as well? What benefit’s both technologies could bring to each other?
Let me take this questions and provide you a short journey through existing deployment models and use cases for AI software. On practical examples, we discuss what cloud/on-premise strategy we may need for applying it to our own infrastructure to get it to work from an enterprise perspective. I want to give an overview about infrastructure requirements and technologies, what could be beneficial or limiting your AI use cases in an enterprise environment. An interactive Demo will give you some insides, what approaches I got already working for real.
Generating a custom Ruby SDK for your web service or Rails API using Smithyg2nightmarescribd
Have you ever wanted a Ruby client API to communicate with your web service? Smithy is a protocol-agnostic language for defining services and SDKs. Smithy Ruby is an implementation of Smithy that generates a Ruby SDK using a Smithy model. In this talk, we will explore Smithy and Smithy Ruby to learn how to generate custom feature-rich SDKs that can communicate with any web service, such as a Rails JSON API.
Elevating Tactical DDD Patterns Through Object CalisthenicsDorra BARTAGUIZ
After immersing yourself in the blue book and its red counterpart, attending DDD-focused conferences, and applying tactical patterns, you're left with a crucial question: How do I ensure my design is effective? Tactical patterns within Domain-Driven Design (DDD) serve as guiding principles for creating clear and manageable domain models. However, achieving success with these patterns requires additional guidance. Interestingly, we've observed that a set of constraints initially designed for training purposes remarkably aligns with effective pattern implementation, offering a more ‘mechanical’ approach. Let's explore together how Object Calisthenics can elevate the design of your tactical DDD patterns, offering concrete help for those venturing into DDD for the first time!
UiPath Test Automation using UiPath Test Suite series, part 3DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 3. In this session, we will cover desktop automation along with UI automation.
Topics covered:
UI automation Introduction,
UI automation Sample
Desktop automation flow
Pradeep Chinnala, Senior Consultant Automation Developer @WonderBotz and UiPath MVP
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
Encryption in Microsoft 365 - ExpertsLive Netherlands 2024Albert Hoitingh
In this session I delve into the encryption technology used in Microsoft 365 and Microsoft Purview. Including the concepts of Customer Key and Double Key Encryption.
GraphRAG is All You need? LLM & Knowledge GraphGuy Korland
Guy Korland, CEO and Co-founder of FalkorDB, will review two articles on the integration of language models with knowledge graphs.
1. Unifying Large Language Models and Knowledge Graphs: A Roadmap.
https://arxiv.org/abs/2306.08302
2. Microsoft Research's GraphRAG paper and a review paper on various uses of knowledge graphs:
https://www.microsoft.com/en-us/research/blog/graphrag-unlocking-llm-discovery-on-narrative-private-data/
DevOps and Testing slides at DASA ConnectKari Kakkonen
My and Rik Marselis slides at 30.5.2024 DASA Connect conference. We discuss about what is testing, then what is agile testing and finally what is Testing in DevOps. Finally we had lovely workshop with the participants trying to find out different ways to think about quality and testing in different parts of the DevOps infinity loop.
JMeter webinar - integration with InfluxDB and GrafanaRTTS
Watch this recorded webinar about real-time monitoring of application performance. See how to integrate Apache JMeter, the open-source leader in performance testing, with InfluxDB, the open-source time-series database, and Grafana, the open-source analytics and visualization application.
In this webinar, we will review the benefits of leveraging InfluxDB and Grafana when executing load tests and demonstrate how these tools are used to visualize performance metrics.
Length: 30 minutes
Session Overview
-------------------------------------------
During this webinar, we will cover the following topics while demonstrating the integrations of JMeter, InfluxDB and Grafana:
- What out-of-the-box solutions are available for real-time monitoring JMeter tests?
- What are the benefits of integrating InfluxDB and Grafana into the load testing stack?
- Which features are provided by Grafana?
- Demonstration of InfluxDB and Grafana using a practice web application
To view the webinar recording, go to:
https://www.rttsweb.com/jmeter-integration-webinar
Builder.ai Founder Sachin Dev Duggal's Strategic Approach to Create an Innova...Ramesh Iyer
In today's fast-changing business world, Companies that adapt and embrace new ideas often need help to keep up with the competition. However, fostering a culture of innovation takes much work. It takes vision, leadership and willingness to take risks in the right proportion. Sachin Dev Duggal, co-founder of Builder.ai, has perfected the art of this balance, creating a company culture where creativity and growth are nurtured at each stage.
Slack (or Teams) Automation for Bonterra Impact Management (fka Social Soluti...Jeffrey Haguewood
Sidekick Solutions uses Bonterra Impact Management (fka Social Solutions Apricot) and automation solutions to integrate data for business workflows.
We believe integration and automation are essential to user experience and the promise of efficient work through technology. Automation is the critical ingredient to realizing that full vision. We develop integration products and services for Bonterra Case Management software to support the deployment of automations for a variety of use cases.
This video focuses on the notifications, alerts, and approval requests using Slack for Bonterra Impact Management. The solutions covered in this webinar can also be deployed for Microsoft Teams.
Interested in deploying notification automations for Bonterra Impact Management? Contact us at sales@sidekicksolutionsllc.com to discuss next steps.
Securing your Kubernetes cluster_ a step-by-step guide to success !KatiaHIMEUR1
Today, after several years of existence, an extremely active community and an ultra-dynamic ecosystem, Kubernetes has established itself as the de facto standard in container orchestration. Thanks to a wide range of managed services, it has never been so easy to set up a ready-to-use Kubernetes cluster.
However, this ease of use means that the subject of security in Kubernetes is often left for later, or even neglected. This exposes companies to significant risks.
In this talk, I'll show you step-by-step how to secure your Kubernetes cluster for greater peace of mind and reliability.
LF Energy Webinar: Electrical Grid Modelling and Simulation Through PowSyBl -...DanBrown980551
Do you want to learn how to model and simulate an electrical network from scratch in under an hour?
Then welcome to this PowSyBl workshop, hosted by Rte, the French Transmission System Operator (TSO)!
During the webinar, you will discover the PowSyBl ecosystem as well as handle and study an electrical network through an interactive Python notebook.
PowSyBl is an open source project hosted by LF Energy, which offers a comprehensive set of features for electrical grid modelling and simulation. Among other advanced features, PowSyBl provides:
- A fully editable and extendable library for grid component modelling;
- Visualization tools to display your network;
- Grid simulation tools, such as power flows, security analyses (with or without remedial actions) and sensitivity analyses;
The framework is mostly written in Java, with a Python binding so that Python developers can access PowSyBl functionalities as well.
What you will learn during the webinar:
- For beginners: discover PowSyBl's functionalities through a quick general presentation and the notebook, without needing any expert coding skills;
- For advanced developers: master the skills to efficiently apply PowSyBl functionalities to your real-world scenarios.
2. 2
Table of Contents
Functional Description ........................................................................3
Installation...........................................................................................3
Power Source .....................................................................................3
Power Connection...............................................................................3
Fiber Input / Output Connections ........................................................4
Video Output Connection....................................................................4
Data Input / Output Connections.........................................................4
Data Configuration ..............................................................................4
Switch/Jumper Settings.......................................................................5
MRM-1485-2F8 Status LED Indicators ...............................................6
RS-485 Termination and Offset Bias Requirements...........................7
Warranty and Service Information ......................................................8
3. 3
INSTALLATION AND OPERATION INSTRUCTIONS
INTRODUCTION
Thank you for purchasing your American Fibertek MRM-1485-2F8 multimode mini video
receiver with RS485 transceiver. Please take a few minutes to read these installation
instructions in order to obtain the maximum performance from this product.
FUNCTIONAL DESCRIPTION
The MRM-1485-2F8 operates as half of a transmitter / receiver pair for the transmission of
baseband NTSC, PAL, RS170, or RS343 video signals and bi-directional RS485 data. It is
designed to operate with the MTM-1485-2F8 or RTM-1485-2F8 video transmitter with RS485
transceiver over two multimode fibers.
The MRM-1485-2F8 converts a FM modulated optical fiber input into a single video output and a
single RS485 output using an 850 nm wavelength detector. The MRM-1485-2F8 also converts
an electrical RS485 input signal into an optical RS485 output returning on a separate fiber using
an 850 nm wavelength source. This unit may be configured for two wire half duplex or four wire
full duplex electrical interfaces. The M1485-2F8 Series product is designed to operate over an
optical loss budget range of 0 to 12 dB. The MRM-1485-2F8 operates on 50 um or 62.5 um
multimode fiber. Refer to the data sheets for detailed performance specifications.
This unit is contained in a compact and rugged aluminum housing with internal dc voltage
regulation. The detachable terminal block and LED indicators provide for easy installation and
monitoring of video, data, and dc power.
The MRM-1485-2F8 is designed for mounting as a modular stand alone unit. For a rack
mounted version please see the RRM-1485-2F8.
INSTALLATION
THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND
SHOULD CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND LOCAL
CODES.
Mount the unit to a secure surface using #8 (3mm) hardware in four places. See the drawing on
the next page for mounting dimensions. Be sure to allow sufficient room for the required
minimum bend radius of the fiber cable used.
POWER SOURCE
THIS PRODUCT SHALL BE POWERED BY A LISTED CLASS 2 POWER SUPPLY ONLY.
The unit requires a +12VDC power source for proper operation. The DC input is diode
protected. In the USA and in Canada an American Fibertek PS-12 is supplied with this unit. The
negative side of the power input is directly connected to ground. ANSI/NFPA 70 Class 2 wiring
is recommended.
POWER CONNECTION
Power is supplied to the unit via a two pin terminal connector. Follow the label on unit for proper
orientation of +12 volt dc and ground.
4. 4
FIBER INPUT / OUTPUT CONNECTIONS
The fiber optic connections are made via ST connectors located on the right side of the unit.
Please note that Fiber Out on the MRM-1485-2F8 is connected to Fiber In on the MTM-1485-
2F8 or RTM-1485-2F8. The reverse flow follows the same orientation.
VIDEO OUTPUT CONNECTION
The video output connection is made via a BNC connector on the right side of the unit. The 75Ω
video output can be looped through typical baseband video inputs of switchers, recorders and
other equipment as required. For proper operation, the output must be terminated with 75Ω. For
optimum performance the video cables should be the shortest length of coax practical.
DATA INPUT / OUTPUT CONNECTIONS
Data input and output connections are made via a terminal block on the right side of the unit.
Follow label on unit for proper orientation of RS485 data input and output. Please note that two
wire applications utilize the four wire Data Out + and Data Out - terminals. Also note that in four
wire installations Data In on the MRM-1485-2F8 becomes Data Out on the MTM-1485-2F8 or
RTM-1485-2F8 after going across the fiber. The reverse flow follows the same orientation.
DATA CONFIGURATION
The MRM-1485-2F8 is shipped from the factory in the RS485 4-wire configuration. In order
to configure the unit for RS485 two wire operation, the unit needs to be opened up and
several switch settings and jumper pins need to be modified using the internal
switch/jumper settings shown on the next page.
The MRM-1485-2F8 is shipped from the factory with internal data input and output 120
ohm terminations switched on. In order to remove the internal terminations, the unit
needs to be opened up and several switch settings need to be modified using the internal
switch/jumper settings shown on the next page.
See page 7 for an explanation of termination and offset bias requirements for RS485 data. To
open the MRM-1485-2F8, remove the screw on the bottom of the module. Also remove two
screws holding the end panel to the chassis on the side with the video and data connections.
Slide PCB assembly out of chassis to access the switch and jumper locations.
6. 6
MRM-1485-2F8 STATUS INDICATORS
The MRM-1485-2F8 receiver provides the following LED status indicators to aid in installation
and troubleshooting:
OLI
A bi-color LED indicator monitors the optical input power of the video and data signal that is
being received at the MRM-1485-2F8 from the MTM-1485-2F8 or the RTM-1485-2F8. DC
power and optical input status associated with this LED are summarized below.
Optical Level Indicator DC Power Status Optical Status
Green On Proper Optical Input Power Present
Red On Optical Input Not Detected
Off Off Check Power Supply
DATA TX
A red LED indicator is provided to monitor the RS485 input data from the electrical interface,
through the MRM-1485-2F8, and out onto the fiber. The intensity of this indicator will vary with
input data patterns, however in typical applications it will cycle on and off as data is transmitted.
RS485 status associated with this LED is summarized below.
DATA TX LED RS485 Status
Red Data Flow Present
Off Data Flow Not Detected
DATA RX
A red LED indicator is provided to monitor the RS485 data coming in from the fiber, through the
MRM-1485-2F8, and out onto the electrical interface. The intensity of this indicator will vary with
input data patterns, however in typical applications it will cycle on and off as data is received.
RS485 status associated with this LED is summarized below.
DATA RX LED RS485 Status
Red Data Flow Present
Off Data Flow Not Detected
7. 7
RS485 TERMINATIONS
The RS485 protocol is an expanded version of the original RS422 protocol. The RS485 protocol
is an expanded version of the original RS422 protocol. RS485 differs from RS422 in the ability
of the transmitter devices to go into a high impedance (Hi-Z) state. This allows multiple
transmitter devices to reside on the same wire pair. The software must dictate a protocol that
allows one device to transmit at any one time to prevent data crashes. Data wiring can use two
wires or four wires. Using two wires the system works in half duplex. This means that data is
exchanged between two points sequentially. When a four-wire system is used, the system may
be full duplex. In many cases the system head end controller will continuously poll data from all
remote devices. The remote devices all respond back to the head end (one at a time!) as they
are addressed. This property of the network rests solely in the hands of the software or
firmware.
The driver chips used in RS485 communications are capable of changing into their high
impedance state very rapidly. On even short lengths of wire there can exist a residual voltage
after a driver circuit turns off. This can interfere with circuits that are used to detect the Hi-Z
state. It is very important that the copper communications lines be terminated with resistors
across the data wire pair. The best place to locate such resistors is at the furthest electrical
devices at the ends of the wire pair. For instance, if several RS485 devices are connected in a
daisy chain fashion, the wire connection would loop across all devices in a chain. The furthest
two points in the chain would need to be terminated. A termination resistor for RS485 input data
can be selected in the MRM-1485-2F8 using switch # 1. A termination resistor for RS485 output
data can be selected in the MRM-1485-2F8 using switch # 2.
OFFSET BIAS – RS485
The RS485 specification requires receivers to detect input signals down to 200mVp-p of voltage
level. In many cases this can cause systems to be sensitive to noise on the data wires. In an
effort to eliminate the effects of low levels of noise, some manufacturers of equipment that
communicate using RS485 have introduced a small voltage bias to the data lines. This is
usually accomplished using 470 Ohm resistance to +5V on the positive line and 470 Ohm
resistance to ground on the negative line. When used in conjunction with the appropriate
termination resistors referred to in the previous section, this introduces about a 300 mV offset,
improving noise immunity.
Offset bias for RS485 can be applied on the MRM-1485-2F8 by setting switch # 3 and switch #
4 on. Please note that these switches work as a set and must be either both on or both off. In a
majority of cases, bias will not be required and these switches should remain in the off position.
If using offset bias, it is important that termination resistor switch # 2 be on (applied) position.
Using offset bias without a termination on the line will cause communications to fail.
8. 8
LIFETIME WARRANTY INFORMATION
American Fibertek, Inc warrants that at the time of delivery the products delivered will be free of
defects in materials and workmanship. Defective products will be repaired or replaced at the
exclusive option of American Fibertek. A Return Material Authorization (RMA) number is
required to send the products back in case of return. All returns must be shipped prepaid. This
warranty is void if the products have been tampered with. This warranty shall be construed in
accordance with New Jersey law and the courts of New Jersey shall have exclusive jurisdiction
over this contract. EXCEPT FOR THE FOREGOING WARRANTY, THERE IS NO WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE,
EXPRESSED OR IMPLIED, WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN
THIS AGREEMENT. In any event, American Fibertek will not be responsible or liable for
contingent, consequential, or incidental damages. No agreement or understanding, expressed
or implied, except as set forth in this warranty, will be binding upon American Fibertek unless in
writing, signed by a duly authorized officer of American Fibertek.
SERVICE INFORMATION
There are no user serviceable parts inside the unit.
In the event that service is required to this unit, please direct all inquiries to:
American Fibertek, Inc. Phone: (877) 234-7200
120 Belmont Drive Phone: (732) 302-0660
Somerset, NJ 08873 FAX (732) 302-0667
E-mail: techinfo@americanfibertek.com