This document describes the development and validation of a stability-indicating RP-HPLC method for the analysis of Methylphenidate Hydrochloride (MPH) and its impurities in pharmaceutical formulations. The method uses a C18 column with a mobile phase of methanol, acetonitrile and buffer at pH 4. MPH and its two impurities were well separated within 6 minutes. The method was validated per ICH guidelines and shown to be accurate, precise, linear, robust and stability-indicating. It can be used to analyze MPH content and degradation products in quality control testing.
A REVIEW ON ETORICOXIB AND PREGABALIN IN METHOD VALIDATION BY RP-HPLCUpexaBavadiya
Development and Validation for Simultaneous Estimation of Etoricoxib and Pregabalin in Bulk and Tablet Dosage Form by RP-HPLC 2K20,GTU,MASTER IN PHARMACY IN QA
Method Development and Validation for Simultaneous Estimation of Dasatinib an...YogeshIJTSRD
The present study describes a newly developed, optimized and validated isocratic RP HPLC method for the separation of two tyrosine kinase inhibitors Dasatinib DST and Erlotinib ERT with Methyl paraben MPB as internal standard IS , in bulk and pharmaceutical formulations with the aid of Chemometrics, multi criteria decision making MCDM approach. The separation was achieved by using Phenomenex Enable C18 column 15×4.6 mm id, 5µm particle size and PDA UV detection at 277nm.The range of independent variables used for the optimization were MeOH 60 70 , pH 2 2.5 and flow rate 0.3 0.8ml min. The influence of these independent variables on the output responses capacity factor of the first peak k1 , resolution Rs and separation a of the second peak and retention time tR3 were evaluated. Using this strategy, mathematical model was defined, and response surface were derived for the separation. The coefficients of determination R2 were more than 0.9258 for all the models. The four responses were simultaneously optimized by using Derringers desirability functions and MCDM approach. Optimum conditions chosen for assay were MeOH, 0.01mM KH2PO4 pH 2.5±0.5 adjusted with diluted orthophosphoric acid solution 68.03 31.97v v and flow rate of 0.8 mL min. Peak area ratio of the analyte and internal standard was used for the quantification of pharmaceutical formulation samples. Total chromatographic analysis time per sample was approximately 9.0 min with DST, MPB IS and ERT eluting with retention times of 2.7, 3.2, and 6.0 minutes respectively. The optimized assay condition was validated as per ICH guidelines and applied for the quantitative analysis Sprycel DST tablet and Tarceva ERT capsule. Dara. Varun | Kumaraswamy. Gandla | R. Lalitha | M. Muralikrishna "Method Development and Validation for Simultaneous Estimation of Dasatinib and Erlotinib by Using RP-HPLC in Pharmaceutical Dosage Form" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-5 | Issue-3 , April 2021, URL: https://www.ijtsrd.com/papers/ijtsrd41117.pdf Paper URL: https://www.ijtsrd.com/pharmacy/other/41117/method-development-and-validation-for-simultaneous-estimation-of-dasatinib-and-erlotinib-by-using-rphplc-in-pharmaceutical-dosage-form/dara-varun
A REVIEW ON ETORICOXIB AND PREGABALIN IN METHOD VALIDATION BY RP-HPLCUpexaBavadiya
Development and Validation for Simultaneous Estimation of Etoricoxib and Pregabalin in Bulk and Tablet Dosage Form by RP-HPLC 2K20,GTU,MASTER IN PHARMACY IN QA
Method Development and Validation for Simultaneous Estimation of Dasatinib an...YogeshIJTSRD
The present study describes a newly developed, optimized and validated isocratic RP HPLC method for the separation of two tyrosine kinase inhibitors Dasatinib DST and Erlotinib ERT with Methyl paraben MPB as internal standard IS , in bulk and pharmaceutical formulations with the aid of Chemometrics, multi criteria decision making MCDM approach. The separation was achieved by using Phenomenex Enable C18 column 15×4.6 mm id, 5µm particle size and PDA UV detection at 277nm.The range of independent variables used for the optimization were MeOH 60 70 , pH 2 2.5 and flow rate 0.3 0.8ml min. The influence of these independent variables on the output responses capacity factor of the first peak k1 , resolution Rs and separation a of the second peak and retention time tR3 were evaluated. Using this strategy, mathematical model was defined, and response surface were derived for the separation. The coefficients of determination R2 were more than 0.9258 for all the models. The four responses were simultaneously optimized by using Derringers desirability functions and MCDM approach. Optimum conditions chosen for assay were MeOH, 0.01mM KH2PO4 pH 2.5±0.5 adjusted with diluted orthophosphoric acid solution 68.03 31.97v v and flow rate of 0.8 mL min. Peak area ratio of the analyte and internal standard was used for the quantification of pharmaceutical formulation samples. Total chromatographic analysis time per sample was approximately 9.0 min with DST, MPB IS and ERT eluting with retention times of 2.7, 3.2, and 6.0 minutes respectively. The optimized assay condition was validated as per ICH guidelines and applied for the quantitative analysis Sprycel DST tablet and Tarceva ERT capsule. Dara. Varun | Kumaraswamy. Gandla | R. Lalitha | M. Muralikrishna "Method Development and Validation for Simultaneous Estimation of Dasatinib and Erlotinib by Using RP-HPLC in Pharmaceutical Dosage Form" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-5 | Issue-3 , April 2021, URL: https://www.ijtsrd.com/papers/ijtsrd41117.pdf Paper URL: https://www.ijtsrd.com/pharmacy/other/41117/method-development-and-validation-for-simultaneous-estimation-of-dasatinib-and-erlotinib-by-using-rphplc-in-pharmaceutical-dosage-form/dara-varun
An emerging way of estimation of Olmesartan medoxomil & Hydrochlorothiazide i...Priyanka Bose
An emerging way of estimation of Olmesartan medoxomil & Hydrochlorothiazide in Bulk & Combined tablet dosage form by Absorbance Correction Method using methanol as solvent system. It is cost effective, highly precised method for estimation.
Stability indicating analytical method development and validation for estimat...SriramNagarajan18
Stability indicating analytical method development and validation for estimation of Sacubitril and Valsartan in bulk and pharmaceutical dosage form using RP-HPLC
Spectrophotometric Estimation of Rosuvastatin Calcium in Bulk and Pharmaceuti...SriramNagarajan15
Rosuvastatin calcium of the class statins is used for primary hyperlipidemias. It is a selective and competitive inhibitor of HMG-CoA reductase. In the present work, simple, sensitive and economic spectrophotometric method has been developed for quantitative determination of Rosuvastatin calcium. In the present spectrophotometric method Rosuvastatin calcium was dissolved in double distilled water. It exhibited an absorption maximum at 241 nm and obeyed Beer’s law in the concentration range of 5-25g/ml. The results of analysis have been validated and found to be sensitive, precise and accurate for quantitative determination of Rosuvastatin calcium in bulk drug and pharmaceutical formulations.
Development and Validation of Stability Indicating Assay Method of Montelukas...ijtsrd
Background A simple, precise cost effective stability indicating assay method of Montelukast by RP HPLC. Material Chromatographic separation was achieved on a Meteoric core C18 column 100mm x 4.6 mm, 2.7µm using a mobile phase 2 ml Trifluroacetic acid mixture of acetonitrile 250ml and methanol 400ml 350 650 at a flow rate of 1.5ml per minute. Wavelength was detection at 255nm. The retention time of Montelukast was 4 minutes. Results The method was found linear concentration the range of 120.39 802.57µg ml, tablet analysis of RSD 0.403, accuracy range 30 , 50 , 100 , and 200 , Precision RSD 0.3. The proposed method was validated as per the ICH guidelines. Conclusion The HPLC method was validated and demonstrated good linearity, precision, accuracy, specificity, robustness and stability indicating. The development HPLC method can be utilized for routine analysis stability studies for Montelukast. Miss. Harshada Ravindra Patil | Mr. Pavan Nathu Patil "Development and Validation of Stability Indicating Assay Method of Montelukast Tablet by RP-HPLC" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-4 | Issue-1 , December 2019, URL: https://www.ijtsrd.com/papers/ijtsrd29809.pdf Paper URL: https://www.ijtsrd.com/pharmacy/analytical-chemistry/29809/development-and-validation-of-stability-indicating-assay-method-of-montelukast-tablet-by-rp-hplc/miss-harshada-ravindra-patil
Spectrophotometric determination of a few commercial drugs using NBS and Rhod...IOSR Journals
Simple, sensitive and selective methods are developed for the spectrophotometric determination of drugs, viz., Montelukast sodium, Prasugrel, Ondensetron, Rosuvastatin calcium, Amlodepine besylate based on their reactivity towards N- bromosuccinimide (NBS). The method involves the addition of excess NBS of known concentration in the presence of 1M HCl, reactants are allowed to react and the unreacted NBS is estimated by the measurement in the decrease in the absorbance of the Rhodamine-B dye (λmax 557nm). This method has been applied for the determination of drugs in their pure form as well as in tablet formulations
METHOD VALIDATION AND STABILITY METHOD OF TELMISARTAN AND EFONIDIPINE IN RPHP...godhat ankur
DEVELOPMENT AND VALIDATION OF STABILITY INDICATING RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF EFONIDIPIN HYDROCHLORIDE ETHANOLATE AND TELMISARTAN IN SYNTHETIC MIXTURE
A newly validated HPLC method development for simultaneous estimation of rito...SriramNagarajan19
The aim of the present work was to develop a isocratict RP-HPLC for simultaneous analysis of ritonavir and lopinavir in tablet dosage form. Method: chromatographic system was optimized using a Agilent XDB C18(150 x 4.6mm,5µm) column with potassium dihydrogen phosphate (pH 4.6) and acetonitrile in the ratio of 45;55, as a mobile phase, at a flow rate of 1.0 ml/min. detection was carried out at 215nm by a photodiode array detector. Result: ritonavir and lopinavir were eluted with retention times of 4.821 and 3.814mins respectively. Beer’s lambert’s law was obeyed over the concentration ranges of 12.5 to 50µg/ml and 50 to 200µg/ml for ritonavir and lopinavir, respectively. Conclusion: the high recovery and low coefficients of variation confirm the suitability of the method for simultaneous analysis of both drugs in a tablet dosage form. Statistical analysis proves that the method is sensitive and significant for the analysis of ritonavir and lopinavir in pure and in pharmaceutical dosage form without any interference from the excipients. The method was validated in accordance with ICH guidelines. Validation revealed the method is specific, rapid, accurate, precise, reliable, and reproducible.
ETORICOXIB AND PREGABALIN OF METHOD DEVLOPMENT IN RPHPLC BY UPEXA BAVADIYAUpexaBavadiya
Development and Validation for Simultaneous Estimation of Etoricoxib and Pregabalin in Bulk and Tablet Dosage Form by RP-HPLC 2K21 GTU MASTER IN PHARMACY BY UPEXA BAVADIYA
The drug or drug combination may not be official in any pharmacopoeias.
A proper analytical procedure for the drug may not be available in the literature due to patent regulations.
Analytical methods may not be available for the drug in the form of a formulation due to the interference caused by the formulation excipients.
Analytical methods for the quantitation of the drug in biological fluids may not be available.
Analytical methods for a drug in combination with other drugs may not be available.
The existing analytical procedures may require expensive reagents and solvents. It may also involve cumbersome extraction and separation procedures and these may not be reliable.
Method Development and Validation for Estimation of Oral Hypoglycaemic Drug D...ijtsrd
HPLC is a chromatographic technique employed in active compound chemistry and biochemistry to separate a mixture and substances with the goal of identifying, measuring, and purifying the different components of the mixture. Its a much better variety of column and traditional chromatography. The objective of the research work is to develop and validate a simple and accurate reverse phase chromatographic method to estimate amount of drug in dosage form. The developed method successfully can be applied to estimate the amount of Dapagliflozin in tablet dosage form. After oral administration of dapagliflozin, the maximum plasma concentration Concentration max under two hours. High performance liquid chromatographic system was alleviated according to the chromatographic settings. After attaining the steady base line, to verify the system suitability, a single 40 µg ml of standard solution proportional to 100 test concentration of dapagliflozin was injected into the HPLC system. The gradient mobile phase flow rate programming assisted in optimising the lengthy run duration and resolution of sample analysis, making the approach more cost effective and quick. Validation of the developed and optimized HPLC method was carried out according to ICH guidelines with respect to parameters such as linearity, specificity, precision and accuracy. Junaid Ahmed | Himanchal Sharma | Shiva Teotia "Method Development and Validation for Estimation of Oral Hypoglycaemic Drug Dapagliflozinina Tablet Dosage form by the Employment of Rp-HPLC" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-5 | Issue-6 , October 2021, URL: https://www.ijtsrd.com/papers/ijtsrd46395.pdf Paper URL : https://www.ijtsrd.com/pharmacy/analytical-chemistry/46395/method-development-and-validation-for-estimation-of-oral-hypoglycaemic-drug-dapagliflozinina-tablet-dosage-form-by-the-employment-of-rphplc/junaid-ahmed
An emerging way of estimation of Olmesartan medoxomil & Hydrochlorothiazide i...Priyanka Bose
An emerging way of estimation of Olmesartan medoxomil & Hydrochlorothiazide in Bulk & Combined tablet dosage form by Absorbance Correction Method using methanol as solvent system. It is cost effective, highly precised method for estimation.
Stability indicating analytical method development and validation for estimat...SriramNagarajan18
Stability indicating analytical method development and validation for estimation of Sacubitril and Valsartan in bulk and pharmaceutical dosage form using RP-HPLC
Spectrophotometric Estimation of Rosuvastatin Calcium in Bulk and Pharmaceuti...SriramNagarajan15
Rosuvastatin calcium of the class statins is used for primary hyperlipidemias. It is a selective and competitive inhibitor of HMG-CoA reductase. In the present work, simple, sensitive and economic spectrophotometric method has been developed for quantitative determination of Rosuvastatin calcium. In the present spectrophotometric method Rosuvastatin calcium was dissolved in double distilled water. It exhibited an absorption maximum at 241 nm and obeyed Beer’s law in the concentration range of 5-25g/ml. The results of analysis have been validated and found to be sensitive, precise and accurate for quantitative determination of Rosuvastatin calcium in bulk drug and pharmaceutical formulations.
Development and Validation of Stability Indicating Assay Method of Montelukas...ijtsrd
Background A simple, precise cost effective stability indicating assay method of Montelukast by RP HPLC. Material Chromatographic separation was achieved on a Meteoric core C18 column 100mm x 4.6 mm, 2.7µm using a mobile phase 2 ml Trifluroacetic acid mixture of acetonitrile 250ml and methanol 400ml 350 650 at a flow rate of 1.5ml per minute. Wavelength was detection at 255nm. The retention time of Montelukast was 4 minutes. Results The method was found linear concentration the range of 120.39 802.57µg ml, tablet analysis of RSD 0.403, accuracy range 30 , 50 , 100 , and 200 , Precision RSD 0.3. The proposed method was validated as per the ICH guidelines. Conclusion The HPLC method was validated and demonstrated good linearity, precision, accuracy, specificity, robustness and stability indicating. The development HPLC method can be utilized for routine analysis stability studies for Montelukast. Miss. Harshada Ravindra Patil | Mr. Pavan Nathu Patil "Development and Validation of Stability Indicating Assay Method of Montelukast Tablet by RP-HPLC" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-4 | Issue-1 , December 2019, URL: https://www.ijtsrd.com/papers/ijtsrd29809.pdf Paper URL: https://www.ijtsrd.com/pharmacy/analytical-chemistry/29809/development-and-validation-of-stability-indicating-assay-method-of-montelukast-tablet-by-rp-hplc/miss-harshada-ravindra-patil
Spectrophotometric determination of a few commercial drugs using NBS and Rhod...IOSR Journals
Simple, sensitive and selective methods are developed for the spectrophotometric determination of drugs, viz., Montelukast sodium, Prasugrel, Ondensetron, Rosuvastatin calcium, Amlodepine besylate based on their reactivity towards N- bromosuccinimide (NBS). The method involves the addition of excess NBS of known concentration in the presence of 1M HCl, reactants are allowed to react and the unreacted NBS is estimated by the measurement in the decrease in the absorbance of the Rhodamine-B dye (λmax 557nm). This method has been applied for the determination of drugs in their pure form as well as in tablet formulations
METHOD VALIDATION AND STABILITY METHOD OF TELMISARTAN AND EFONIDIPINE IN RPHP...godhat ankur
DEVELOPMENT AND VALIDATION OF STABILITY INDICATING RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF EFONIDIPIN HYDROCHLORIDE ETHANOLATE AND TELMISARTAN IN SYNTHETIC MIXTURE
A newly validated HPLC method development for simultaneous estimation of rito...SriramNagarajan19
The aim of the present work was to develop a isocratict RP-HPLC for simultaneous analysis of ritonavir and lopinavir in tablet dosage form. Method: chromatographic system was optimized using a Agilent XDB C18(150 x 4.6mm,5µm) column with potassium dihydrogen phosphate (pH 4.6) and acetonitrile in the ratio of 45;55, as a mobile phase, at a flow rate of 1.0 ml/min. detection was carried out at 215nm by a photodiode array detector. Result: ritonavir and lopinavir were eluted with retention times of 4.821 and 3.814mins respectively. Beer’s lambert’s law was obeyed over the concentration ranges of 12.5 to 50µg/ml and 50 to 200µg/ml for ritonavir and lopinavir, respectively. Conclusion: the high recovery and low coefficients of variation confirm the suitability of the method for simultaneous analysis of both drugs in a tablet dosage form. Statistical analysis proves that the method is sensitive and significant for the analysis of ritonavir and lopinavir in pure and in pharmaceutical dosage form without any interference from the excipients. The method was validated in accordance with ICH guidelines. Validation revealed the method is specific, rapid, accurate, precise, reliable, and reproducible.
ETORICOXIB AND PREGABALIN OF METHOD DEVLOPMENT IN RPHPLC BY UPEXA BAVADIYAUpexaBavadiya
Development and Validation for Simultaneous Estimation of Etoricoxib and Pregabalin in Bulk and Tablet Dosage Form by RP-HPLC 2K21 GTU MASTER IN PHARMACY BY UPEXA BAVADIYA
The drug or drug combination may not be official in any pharmacopoeias.
A proper analytical procedure for the drug may not be available in the literature due to patent regulations.
Analytical methods may not be available for the drug in the form of a formulation due to the interference caused by the formulation excipients.
Analytical methods for the quantitation of the drug in biological fluids may not be available.
Analytical methods for a drug in combination with other drugs may not be available.
The existing analytical procedures may require expensive reagents and solvents. It may also involve cumbersome extraction and separation procedures and these may not be reliable.
Method Development and Validation for Estimation of Oral Hypoglycaemic Drug D...ijtsrd
HPLC is a chromatographic technique employed in active compound chemistry and biochemistry to separate a mixture and substances with the goal of identifying, measuring, and purifying the different components of the mixture. Its a much better variety of column and traditional chromatography. The objective of the research work is to develop and validate a simple and accurate reverse phase chromatographic method to estimate amount of drug in dosage form. The developed method successfully can be applied to estimate the amount of Dapagliflozin in tablet dosage form. After oral administration of dapagliflozin, the maximum plasma concentration Concentration max under two hours. High performance liquid chromatographic system was alleviated according to the chromatographic settings. After attaining the steady base line, to verify the system suitability, a single 40 µg ml of standard solution proportional to 100 test concentration of dapagliflozin was injected into the HPLC system. The gradient mobile phase flow rate programming assisted in optimising the lengthy run duration and resolution of sample analysis, making the approach more cost effective and quick. Validation of the developed and optimized HPLC method was carried out according to ICH guidelines with respect to parameters such as linearity, specificity, precision and accuracy. Junaid Ahmed | Himanchal Sharma | Shiva Teotia "Method Development and Validation for Estimation of Oral Hypoglycaemic Drug Dapagliflozinina Tablet Dosage form by the Employment of Rp-HPLC" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-5 | Issue-6 , October 2021, URL: https://www.ijtsrd.com/papers/ijtsrd46395.pdf Paper URL : https://www.ijtsrd.com/pharmacy/analytical-chemistry/46395/method-development-and-validation-for-estimation-of-oral-hypoglycaemic-drug-dapagliflozinina-tablet-dosage-form-by-the-employment-of-rphplc/junaid-ahmed
A series of female figures that I hope to scale up to form the installation, \'Soul~Fields\' - female figures telling the story of the human condition...
The IOSR Journal of Pharmacy (IOSRPHR) is an open access online & offline peer reviewed international journal, which publishes innovative research papers, reviews, mini-reviews, short communications and notes dealing with Pharmaceutical Sciences( Pharmaceutical Technology, Pharmaceutics, Biopharmaceutics, Pharmacokinetics, Pharmaceutical/Medicinal Chemistry, Computational Chemistry and Molecular Drug Design, Pharmacognosy & Phytochemistry, Pharmacology, Pharmaceutical Analysis, Pharmacy Practice, Clinical and Hospital Pharmacy, Cell Biology, Genomics and Proteomics, Pharmacogenomics, Bioinformatics and Biotechnology of Pharmaceutical Interest........more details on Aim & Scope).
Development and Validation of Reversed Phase-High-Performance Liquid Chromato...BRNSS Publication Hub
A simple, accurate, precise, and robust in vitro methods developed and validated for measurement of drug release in Aminocaproic Acid tablets. High-performance liquid chromatography (HPLC) method for quantification of drug in dissolution samples of Aminocaproic Acid tablet is developed and validated. 0.1 N Hydrochloric acid is used as dissolution medium and Basket (USP-I) as apparatus at 100 rpm. The sample was withdrawn after 60 min. The developed HPLC method was used for quantitative estimation of drug release in dissolution samples of Aminocaproic Acid tablet. Chromatogram was run through Inertsil ODS 3V, (250 × 4.6 mm), 5 μm. Mobile phase containing buffer solution and methanol in the pumped through column at a flow rate of 1 ml/min. Buffer used in this method was 13.3 g sodium dihydrogen phosphate monohydrate, 500 mg of Heptane-1-sulfonic acid sodium salt, and 1.0 mL of Triethylamine buffer with pH 2.20 adjusted by orthophosphoric acid. Optimized wavelength for Aminocaproic acid was 210 nm. Retention time of Aminocaproic acid was found about 4.0 min; linearity range was 132.605 μg/ml–828.787 μg/ml. The new method was evaluated according to ICH guideline and as far as validation results are concern correlation coefficient value was 0.9999 for the very compound, percentage recovery 100.0%, repeatability results relative standard deviation 0.9 for Aminocaproic acid. The developed HPLC method was found to be a simple and rapid one for regular analysis in professional laboratory.
IOSR Journal of Pharmacy and Biological Sciences(IOSR-JPBS) is a double blind peer reviewed International Journal that provides rapid publication (within a month) of articles in all areas of Pharmacy and Biological Science. The journal welcomes publications of high quality papers on theoretical developments and practical applications in Pharmacy and Biological Science. Original research papers, state-of-the-art reviews, and high quality technical notes are invited for publications.
Formulation and evaluation ofmetformin HCl micro beads by ionotropic gelation...Sagar Savale
The Metformin HCL Micro Beads is formulated by the Ionotropic Gelation Method. The CMC is a Swellable
polymer is responsible for the Sustained release action or activity. A combination of CMC (Carboxy Methyl
Cellulose) and Sodium Alginate shows better sustained release activity. The PreparedSustained released Micro
Beadsis Evaluated In terms of bulk density, tapped density, angle of repose, Carr’s Index, Swelling Index, Drug
Content, % Encapsulation Efficiency and vitro study. The result associated in Optimized batch is good to
Satisfactory and having a good free flowing property. The Drug Content and % Encapsulation Efficiency values are
within the pharmacopeia limit. The in vitro Dissolution studies shows Maximum percentage of release of drug
(71.15) with in end of 4 Hours.
A brief information about the SCOP protein database used in bioinformatics.
The Structural Classification of Proteins (SCOP) database is a comprehensive and authoritative resource for the structural and evolutionary relationships of proteins. It provides a detailed and curated classification of protein structures, grouping them into families, superfamilies, and folds based on their structural and sequence similarities.
THE IMPORTANCE OF MARTIAN ATMOSPHERE SAMPLE RETURN.Sérgio Sacani
The return of a sample of near-surface atmosphere from Mars would facilitate answers to several first-order science questions surrounding the formation and evolution of the planet. One of the important aspects of terrestrial planet formation in general is the role that primary atmospheres played in influencing the chemistry and structure of the planets and their antecedents. Studies of the martian atmosphere can be used to investigate the role of a primary atmosphere in its history. Atmosphere samples would also inform our understanding of the near-surface chemistry of the planet, and ultimately the prospects for life. High-precision isotopic analyses of constituent gases are needed to address these questions, requiring that the analyses are made on returned samples rather than in situ.
Multi-source connectivity as the driver of solar wind variability in the heli...Sérgio Sacani
The ambient solar wind that flls the heliosphere originates from multiple
sources in the solar corona and is highly structured. It is often described
as high-speed, relatively homogeneous, plasma streams from coronal
holes and slow-speed, highly variable, streams whose source regions are
under debate. A key goal of ESA/NASA’s Solar Orbiter mission is to identify
solar wind sources and understand what drives the complexity seen in the
heliosphere. By combining magnetic feld modelling and spectroscopic
techniques with high-resolution observations and measurements, we show
that the solar wind variability detected in situ by Solar Orbiter in March
2022 is driven by spatio-temporal changes in the magnetic connectivity to
multiple sources in the solar atmosphere. The magnetic feld footpoints
connected to the spacecraft moved from the boundaries of a coronal hole
to one active region (12961) and then across to another region (12957). This
is refected in the in situ measurements, which show the transition from fast
to highly Alfvénic then to slow solar wind that is disrupted by the arrival of
a coronal mass ejection. Our results describe solar wind variability at 0.5 au
but are applicable to near-Earth observatories.
The increased availability of biomedical data, particularly in the public domain, offers the opportunity to better understand human health and to develop effective therapeutics for a wide range of unmet medical needs. However, data scientists remain stymied by the fact that data remain hard to find and to productively reuse because data and their metadata i) are wholly inaccessible, ii) are in non-standard or incompatible representations, iii) do not conform to community standards, and iv) have unclear or highly restricted terms and conditions that preclude legitimate reuse. These limitations require a rethink on data can be made machine and AI-ready - the key motivation behind the FAIR Guiding Principles. Concurrently, while recent efforts have explored the use of deep learning to fuse disparate data into predictive models for a wide range of biomedical applications, these models often fail even when the correct answer is already known, and fail to explain individual predictions in terms that data scientists can appreciate. These limitations suggest that new methods to produce practical artificial intelligence are still needed.
In this talk, I will discuss our work in (1) building an integrative knowledge infrastructure to prepare FAIR and "AI-ready" data and services along with (2) neurosymbolic AI methods to improve the quality of predictions and to generate plausible explanations. Attention is given to standards, platforms, and methods to wrangle knowledge into simple, but effective semantic and latent representations, and to make these available into standards-compliant and discoverable interfaces that can be used in model building, validation, and explanation. Our work, and those of others in the field, creates a baseline for building trustworthy and easy to deploy AI models in biomedicine.
Bio
Dr. Michel Dumontier is the Distinguished Professor of Data Science at Maastricht University, founder and executive director of the Institute of Data Science, and co-founder of the FAIR (Findable, Accessible, Interoperable and Reusable) data principles. His research explores socio-technological approaches for responsible discovery science, which includes collaborative multi-modal knowledge graphs, privacy-preserving distributed data mining, and AI methods for drug discovery and personalized medicine. His work is supported through the Dutch National Research Agenda, the Netherlands Organisation for Scientific Research, Horizon Europe, the European Open Science Cloud, the US National Institutes of Health, and a Marie-Curie Innovative Training Network. He is the editor-in-chief for the journal Data Science and is internationally recognized for his contributions in bioinformatics, biomedical informatics, and semantic technologies including ontologies and linked data.
Observation of Io’s Resurfacing via Plume Deposition Using Ground-based Adapt...Sérgio Sacani
Since volcanic activity was first discovered on Io from Voyager images in 1979, changes
on Io’s surface have been monitored from both spacecraft and ground-based telescopes.
Here, we present the highest spatial resolution images of Io ever obtained from a groundbased telescope. These images, acquired by the SHARK-VIS instrument on the Large
Binocular Telescope, show evidence of a major resurfacing event on Io’s trailing hemisphere. When compared to the most recent spacecraft images, the SHARK-VIS images
show that a plume deposit from a powerful eruption at Pillan Patera has covered part
of the long-lived Pele plume deposit. Although this type of resurfacing event may be common on Io, few have been detected due to the rarity of spacecraft visits and the previously low spatial resolution available from Earth-based telescopes. The SHARK-VIS instrument ushers in a new era of high resolution imaging of Io’s surface using adaptive
optics at visible wavelengths.
Introduction:
RNA interference (RNAi) or Post-Transcriptional Gene Silencing (PTGS) is an important biological process for modulating eukaryotic gene expression.
It is highly conserved process of posttranscriptional gene silencing by which double stranded RNA (dsRNA) causes sequence-specific degradation of mRNA sequences.
dsRNA-induced gene silencing (RNAi) is reported in a wide range of eukaryotes ranging from worms, insects, mammals and plants.
This process mediates resistance to both endogenous parasitic and exogenous pathogenic nucleic acids, and regulates the expression of protein-coding genes.
What are small ncRNAs?
micro RNA (miRNA)
short interfering RNA (siRNA)
Properties of small non-coding RNA:
Involved in silencing mRNA transcripts.
Called “small” because they are usually only about 21-24 nucleotides long.
Synthesized by first cutting up longer precursor sequences (like the 61nt one that Lee discovered).
Silence an mRNA by base pairing with some sequence on the mRNA.
Discovery of siRNA?
The first small RNA:
In 1993 Rosalind Lee (Victor Ambros lab) was studying a non- coding gene in C. elegans, lin-4, that was involved in silencing of another gene, lin-14, at the appropriate time in the
development of the worm C. elegans.
Two small transcripts of lin-4 (22nt and 61nt) were found to be complementary to a sequence in the 3' UTR of lin-14.
Because lin-4 encoded no protein, she deduced that it must be these transcripts that are causing the silencing by RNA-RNA interactions.
Types of RNAi ( non coding RNA)
MiRNA
Length (23-25 nt)
Trans acting
Binds with target MRNA in mismatch
Translation inhibition
Si RNA
Length 21 nt.
Cis acting
Bind with target Mrna in perfect complementary sequence
Piwi-RNA
Length ; 25 to 36 nt.
Expressed in Germ Cells
Regulates trnasposomes activity
MECHANISM OF RNAI:
First the double-stranded RNA teams up with a protein complex named Dicer, which cuts the long RNA into short pieces.
Then another protein complex called RISC (RNA-induced silencing complex) discards one of the two RNA strands.
The RISC-docked, single-stranded RNA then pairs with the homologous mRNA and destroys it.
THE RISC COMPLEX:
RISC is large(>500kD) RNA multi- protein Binding complex which triggers MRNA degradation in response to MRNA
Unwinding of double stranded Si RNA by ATP independent Helicase
Active component of RISC is Ago proteins( ENDONUCLEASE) which cleave target MRNA.
DICER: endonuclease (RNase Family III)
Argonaute: Central Component of the RNA-Induced Silencing Complex (RISC)
One strand of the dsRNA produced by Dicer is retained in the RISC complex in association with Argonaute
ARGONAUTE PROTEIN :
1.PAZ(PIWI/Argonaute/ Zwille)- Recognition of target MRNA
2.PIWI (p-element induced wimpy Testis)- breaks Phosphodiester bond of mRNA.)RNAse H activity.
MiRNA:
The Double-stranded RNAs are naturally produced in eukaryotic cells during development, and they have a key role in regulating gene expression .
Richard's aventures in two entangled wonderlandsRichard Gill
Since the loophole-free Bell experiments of 2020 and the Nobel prizes in physics of 2022, critics of Bell's work have retreated to the fortress of super-determinism. Now, super-determinism is a derogatory word - it just means "determinism". Palmer, Hance and Hossenfelder argue that quantum mechanics and determinism are not incompatible, using a sophisticated mathematical construction based on a subtle thinning of allowed states and measurements in quantum mechanics, such that what is left appears to make Bell's argument fail, without altering the empirical predictions of quantum mechanics. I think however that it is a smoke screen, and the slogan "lost in math" comes to my mind. I will discuss some other recent disproofs of Bell's theorem using the language of causality based on causal graphs. Causal thinking is also central to law and justice. I will mention surprising connections to my work on serial killer nurse cases, in particular the Dutch case of Lucia de Berk and the current UK case of Lucy Letby.
Richard's entangled aventures in wonderlandRichard Gill
Since the loophole-free Bell experiments of 2020 and the Nobel prizes in physics of 2022, critics of Bell's work have retreated to the fortress of super-determinism. Now, super-determinism is a derogatory word - it just means "determinism". Palmer, Hance and Hossenfelder argue that quantum mechanics and determinism are not incompatible, using a sophisticated mathematical construction based on a subtle thinning of allowed states and measurements in quantum mechanics, such that what is left appears to make Bell's argument fail, without altering the empirical predictions of quantum mechanics. I think however that it is a smoke screen, and the slogan "lost in math" comes to my mind. I will discuss some other recent disproofs of Bell's theorem using the language of causality based on causal graphs. Causal thinking is also central to law and justice. I will mention surprising connections to my work on serial killer nurse cases, in particular the Dutch case of Lucia de Berk and the current UK case of Lucy Letby.
Slide 1: Title Slide
Extrachromosomal Inheritance
Slide 2: Introduction to Extrachromosomal Inheritance
Definition: Extrachromosomal inheritance refers to the transmission of genetic material that is not found within the nucleus.
Key Components: Involves genes located in mitochondria, chloroplasts, and plasmids.
Slide 3: Mitochondrial Inheritance
Mitochondria: Organelles responsible for energy production.
Mitochondrial DNA (mtDNA): Circular DNA molecule found in mitochondria.
Inheritance Pattern: Maternally inherited, meaning it is passed from mothers to all their offspring.
Diseases: Examples include Leber’s hereditary optic neuropathy (LHON) and mitochondrial myopathy.
Slide 4: Chloroplast Inheritance
Chloroplasts: Organelles responsible for photosynthesis in plants.
Chloroplast DNA (cpDNA): Circular DNA molecule found in chloroplasts.
Inheritance Pattern: Often maternally inherited in most plants, but can vary in some species.
Examples: Variegation in plants, where leaf color patterns are determined by chloroplast DNA.
Slide 5: Plasmid Inheritance
Plasmids: Small, circular DNA molecules found in bacteria and some eukaryotes.
Features: Can carry antibiotic resistance genes and can be transferred between cells through processes like conjugation.
Significance: Important in biotechnology for gene cloning and genetic engineering.
Slide 6: Mechanisms of Extrachromosomal Inheritance
Non-Mendelian Patterns: Do not follow Mendel’s laws of inheritance.
Cytoplasmic Segregation: During cell division, organelles like mitochondria and chloroplasts are randomly distributed to daughter cells.
Heteroplasmy: Presence of more than one type of organellar genome within a cell, leading to variation in expression.
Slide 7: Examples of Extrachromosomal Inheritance
Four O’clock Plant (Mirabilis jalapa): Shows variegated leaves due to different cpDNA in leaf cells.
Petite Mutants in Yeast: Result from mutations in mitochondrial DNA affecting respiration.
Slide 8: Importance of Extrachromosomal Inheritance
Evolution: Provides insight into the evolution of eukaryotic cells.
Medicine: Understanding mitochondrial inheritance helps in diagnosing and treating mitochondrial diseases.
Agriculture: Chloroplast inheritance can be used in plant breeding and genetic modification.
Slide 9: Recent Research and Advances
Gene Editing: Techniques like CRISPR-Cas9 are being used to edit mitochondrial and chloroplast DNA.
Therapies: Development of mitochondrial replacement therapy (MRT) for preventing mitochondrial diseases.
Slide 10: Conclusion
Summary: Extrachromosomal inheritance involves the transmission of genetic material outside the nucleus and plays a crucial role in genetics, medicine, and biotechnology.
Future Directions: Continued research and technological advancements hold promise for new treatments and applications.
Slide 11: Questions and Discussion
Invite Audience: Open the floor for any questions or further discussion on the topic.
1. Available online www.jocpr.com
Journal of Chemical and Pharmaceutical Research, 2015, 7(5):606-629
Research Article
ISSN : 0975-7384
CODEN(USA) : JCPRC5
606
A stability indicating method development and validation for determination of
Methylphenidate Hydrochloride and its impurities in solid pharmaceutical
oral dosage form by RP-HPLC as per ICH guidelines
Ch. Naveen Kumar1,2
* and N. Kannappan2
1
Bright Labs, Kothapet, Dilshuknagar, Hyderabad, Telangana, India
2
Department of Pharmacy, Faculty of Engineering and Technology, Annamalainagar, Annamalai University,
Chidambaram, Tamilnadu, India
_____________________________________________________________________________________________
ABSTRACT
A simple, rapid, and precise, robust and rugged reverse phase high performance liquid chromatographic (RP-
HPLC) method for analysis of Methylphenidate hydrochloride (MPH) and its Impurities in a tablet dosage form
have been developed and validated. This method condition optimization was performed with HSSD waters symmetry
C18 (100x 40 i.d., 3.7 µm particle column with Mobile phase Methanol: Acetonitrile: buffer (50:20:30v/v/v) and pH
adjusted 4.0 with acetic acid at a flow rate of 1.5 ml/min. The eluted compounds were detected and monitored at
210 nm for Methylphenidate Hydrochloride (MPH) assay and 203 nm for related substances (RS) by PDA detector.
By this method Methylphenidate Hydrochloride (MPH), Imp-A, Imp-B were eluted with retention times of 3.162,
2.349, and 2.792 min, respectively. Validation revealed the method is accurate, precise, reliable, and reproducible.
Calibration curve plots were linear over the concentration ranges 0.1-2.0 µg/mL for Impurities and for MPH 500-
1500 µg/. Limits of detection (LOD) for MPH, Imp-A, Imp-B were 0.03, 0.04, and 0.04µg/ml and limits of
quantification (LOQ) were 0.1, 0.1, 0.1 µg/mL respectively. The statistical analysis proves the method is suitable for
the analysis of MPH, Imp-A, Imp-B in bulk and tablet dosage form without any interference from the excipients. It
was also proved study for degradation kinetics of the drug in tablet dosage form. The developed method separated
MPH from its two known and two unknown impurities within 6.0 min. Methylphenidate Hydrochloride(MPH) was
subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. MPH was
found to degrade significantly in base stress condition, degrade slightly in oxidative stress condition and remain
stable in acid, hydrolytic, thermal and photolytic degradation conditions. All impurities were well resolved from
each other and from the main peak, showing the stability-indicating power of the method. The developed method
was validated as per International Conference on Harmonization (ICH) guidelines.
Keywords: Methylphenidate Hydrochloride (MPH), Impurities, RP-HPLC, Stability Indicating, Method
Development, Validation, ICH guidelines.
_____________________________________________________________________________________________
Methylphenidate Hydrochloride (MPH) is used for the treatment of attention deficit hyperactivity disorder (ADHD)
and narcolepsy, the drug is a CNS stimulant and inhibits the reuptake of dopamine in the synapses [1, 2]. The use of
MPH has increased considerably in recent years.
Methylphenidate hydrochloride (MPH) is used for the treatment of attention deficit hyperactivity disorder (ADHD)
and it is a psycho-stimulant drug approved for the treatment of attention postural orthostatic tachycardia syndrome
and narcolepsy but has also been `prescribed for the off-label treatment of other disorders such as lethargy.
Methylphenidate is the most commonly prescribed psycho-stimulant and works by increasing the activity of central
nervous system. [3, 4]Chemically, methylphenidate is methyl-2-phenyl-2-(piperidin-2-yl) acetate and its impurities
A&B (Fig 1). It blocks dopamine uptake in central adrenergic neurons by blocking dopamine transport or carrier
proteins. Methylphenidate acts at the brain stem arousal system and the cerebral cortex and causes increased
2. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
607
sympathomimetic activity in the central nervous system [4-6] [Fig1(A,B,C) ] Chemical structure of Methylphenidate
Hydrochloride and Its Impurities.
A)Methyl (2RS)-phenyl [(2SR)-piperidin-2-yl] acetate Hydrochloride (MPH)
B) (2RS)-phenyl [(2RS)-piperidine-2-yl] acetic acid (IMP-A)
C) Methyl (2RS)-phenyl [(2SR)-piperidin-2yl] acetate (IMP-B)
Some research studies have theorized that ADHD is caused by a dopamine imbalance in the brains of those affected.
Methylphenidate is a nor epinephrine and dopamine reuptake inhibitor, which means that it increases the level of the
dopamine neurotransmitter in the brain by partially blocking the dopamine transporter (DAT) that removes
dopamine from the synapses. This inhibition of DAT blocks the reuptake of dopamine and nor epinephrine into the
pre synaptic neuron, increasing the amount of dopamine in the synapse. [7, 8]
Literature survey revealed that only few analytical methods like spectrophotometric, RP-HPLC and LCMS methods
[9-11] Gas-chromatographic and gas-chromatographic-mass spectrometric procedures recently described for
quantitation of methylphenidate and ritalinic acid [12-16] require relatively large sample volumes (2-5 mL of plasma
or serum) have been reported for the determination of methylphenidate hydrochloride. All these methods are
expensive, time consuming, complex in nature. Consequently, there is no stability indicating method reported in the
presence of known impurities and also from the unknown degradation products hence, there was still a need to
develop a simple, less time-consuming and economical stability indicating method for the determination of
methylphenidate hydrochloride in pharmaceutical oral dosage forms. Therefore, the attempt was made to develop a
fast and reproducible RP-HPLC method for the estimation Methylphenidate in API and pharmaceutical solid oral
dosage form by following ICH method validation guidelines. In the present work, we developed a simple, precise,
accurate, selective and robust liquid chromatographic method for the determination of Methylphenidate
hydrochloride in API and in solid Dosage forms for routine quality control.
EXPERIMENTAL SECTION
Apparatus:
The analysis was performed using waters-2695(Model alliance) High Performance liquid chromatography waters
auto sampler–PDA detector 996 by using, EmpowerTM-3S-software version-3,analytical balance (Mettler Toledo)
UV/Visible-Detector (Standard cell) and data handling system (Autochrome-3000), pH meter (lab India), Sonicator.
The column used is HDSS waters symmetry C18 (100x 40 i.d., 3.7 µm) particle column.
Materials and Reagents:
Methanol (HPLC Grade), Acetonitrile (HPLC Grade), sodium acetate (AR Grade), acetic acid (AR Grade), pure
drug samples of Methylphenidate Hydrochloride (MPH) and Impurity-A:(2(RS)-Phenyl(2RS)piperdine2-
yl)aceticacid,Impurity-B:(methyl(2SR)-piperidine-2yl) acetate are obtained as gift samples from KDPL
Pharmaceuticals Hyderabad.
3. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
608
Selection of wavelength by UV-Spectroscopy:
The maximum absorbance of MPH and Impurity-A, Impurity-B were found to be 210 and 203 nm respectively from
the UV Visible spectrophotometer results and the detector used in eluent monitoring HPLC is PDA detector.
Preparation of sodium acetate buffer solution:
Dissolve 1.62 gms of sodium acetate in 800 ml of HPLC grade water and adjust to the pH 4.0 with acetic acid and
dilute with HPLC grade water up to 1000ml.the buffer was filtered through 0.45µ nylon membrane filter and
degassed.
Preparation of Mobile Phase:
The mobile phase is consisted a mixture of methanol, acetonitrile, and buffer in the ratio of 50:20:30 (v/v/v), pH is
adjusted to 4.0 with acetic acid and filtered through 0.22 µm nylon membrane filter.
Diluent preparation:
Mobile phase is used as diluents
System suitability solution preparation
Suitability solution is prepared by dissolving standard substances in diluent to obtain solution containing 1000
µg/mL of MPH, 1 µg/mL of Imp-A and 1 µg/mL of Imp-B.
Preparation of Placebo Solution:
Twenty tablets of placebo are crushed to fine powder. An accurately weighed portion of the powder equivalent to 25
mg of MPH is taken into 25 ml volumetric flask. About 20 ml of diluent is added to this volumetric flask and
sonicated in an ultrasonic bath for 10 minutes. Dilute volume up to the mark and mixed well. It is then filtered
through 0.22 µm PVDF syringe filter and the filtrate is collected after discarding first few milliliters.
Preparation of standard solution:
Standard solution are prepared by dissolving the drug MPH working standard in diluent to attain the solution
containing 1000 µg/mL for assay and 1µg/mL for related substances.
Preparation of Sample Solution (Assay):
Sample solution is prepared by dissolving sample Brand name Ritalin Tablets 10 mg Novartis (twenty tablets are
crushed to fine powder by mortar and pestle) in diluent to obtain the solution that containing 1000 µg/mL of MPH
(for assay and related substances). It was then filtered through 0.22 µm PVDF syringe filter and the filtrate is
collected after discarding first few milliliters.
Assay of Pharmaceutical Formulation:
Calculated the the quantity, in mg, of MPH in the portion of solid oral pharmaceutical formulation using the
following formula:
Assay (%w/w) =Cstdx Rs x 10,000
Cs x Rstd
Where,
Cstd= Concentration of standard solution in mg/ml.
Cs= Concentration of sample solution in mg/ml.
Rs= Compound peak response obtained from the sample preparation.
Rstd= Compound peak response (mean peak area) obtained from the standard preparation.
Percentage Impurity in Pharmaceutical Formulation:
For Calculating the % impurity present in the finished product formulation using the following formula:
Impurity (%w/w) = Cstdx Rs x 10,000x1
Cs x R std x RRF
Where,
Cstd= Concentration of standard solution in mg/ml.
Cs= Concentration of sample solution in mg/ml.
Rs= Compound peak response obtained from the sample preparation.
Rstd= Compound peak response (mean peak area) obtained from the standard preparation.
RRF= Compound related response factor.
4. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
609
METHOD VALIDATION
The HPLC method was validate according to ICH Guidelines:
System suitability
System Related suitability parameters are analyzed and measured to verify the system is suitable for its performance.
System precision parameter is determined on considering six replicate injections of standard solution preparation.
All important characteristics features including % RSD, resolution (between MPH and Imp-B), theoretical plate
number and tailing factor are measured.
Precision
The precision of the system related that is repeatability and reproducibility is determined using the sample
preparation procedure as described in above for six same samples of similar solution of formulation and analysis
using the same proposed method and one more is the Intermediate precision is studied by other analyst, using
different columns, different HPLC, and is performed on different days.
Specificity:
Specificity is the ability to assess unequivocally the analyte in the presence of some components which may be
expected to be present. Typically these might include degradants, impurities, matrix, etc. Specificity was determined
by injecting a blank, placebo and also standard solution. No interference should be seen at the retention time of an
analyte. The specificity has to demonstrate by induced degradation of MPH formulation and placebo samples to acid
degradation, alkali degradation, water degradation, peroxide degradation, thermal degradation, and U.V.
degradation.
Accuracy (Recovery)
For the confirming the recovery of the proposed method, recovery related experiments are carried out by
considering the special standard addition technique for assay(MPH) and impurities(Impurity-A, Impurity-B) by
addition technique for related substances. The accuracy of the assay method for MPH is evaluated in triplicate (n=3)
at the five concentrations of 500, 750, 1000, 1250 and 1500 µg/mL (50, 75, 100, 125 and 150 %) of the finished
dosage form product, and the recovery is calculated for each added (externally spiked) concentration. The mean of
percentage recoveries (n=15) and the relative standard deviation are calculated. For all impurities, the recovery is
determined in triplicate (n=3) for 0.5, 0.75, 1.0, 1.25 and 1.5 µg/mL (50, 75, 100, 125 and 150 %) of the analyte
concentration (1000 µg/mL) of the drug finished product, and the recovery of the impurities is calculated. The mean
of percentage recoveries (n=15) and the relative standard deviation are also calculated for related substances.
Linearity
For related impurities or substances test, the linearity is demonstrated from the parameter LOQ (0.1 µg/mL) to 2.0
µg/mL of std concentration of Impurities using a minimum of eight to nine calibration levels (LOQ, 0.2, 0.4, 0.6,
0.8, 1.0, 1.2, 1.5 and 2.0 µg/mL) for Imp-A and Imp-B. For assay test, linearity is demonstrated from 50% to 150%
of standard concentration using a minimum of seven calibration levels (500,700, 800, 1000, 1200, 1400 and 1500
µg/mL) for MPH. The method of linear regression is used for data evaluation. The peak areas of the standard
compounds are plotted against the respective MPH, Impurity-A and Impurity-B concentrations. Linearity is
described by the linearity equation, correlation coefficient and Y-intercept bias is also determined.
Limit of detection (LOD) and limit of quantification (LOQ):
The detection limit of an individual analytical procedure is the lowest amount of analyte in a sample which can be
detected but not necessarily quantitated as an exact value. The quantitation limit of an individual analytical
procedure is the lowest amount of analyte in a sample which can be quantitatively determined with suitable
precision and accuracy. Calculated the LOD & LOQ, with the calculations obtained from evaluation of the
calibration curve of the linearity.LOD and LOQ values are less than the minimum linearity concentration.
Robustness
The robustness it is a measure of the capacity of a method to remain unaffected by small but deliberate changes
in flow rate (± 0.05 mL/min), change in column oven temperature (± 5 °C) and change in organic solvent ratio (±
10%). These all most important characteristic including % assays, resolution (between MPH and Impurity-A,
Impurity-B), tailing factor, theoretical plate’s number and the retention behavior of the certain targeted compound
are evaluated.
Solution stability
The stability of the sample solution is established by storage of the sample solution at ambient temperature for 24h.
The sample solution is re-analyzed after 12 and 24h, and the results of the analysis are compared with the results of
5. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
610
the fresh sample. The stability of standard solution is established by the storage of the standard solution at ambient
temperature for 24h. The standard solution is re-injected after 12, 24 and 48 hrs % RSD is calculated.
Filter compatibility
Filter compatibility is majorly performed for nylon 0.25 µm syringe filter (Whatman sciences) and PVDF 0.25 µm
syringe filter (Millipore). To confirm the filter compatibility in proposed analytical method, filtration recovery
experiment is carried out by sample filtration technique. Need Sample is mainly filtered via both syringe filters and
percentage purity assay is determined and compared to against centrifuged sample.
RESULTS AND DISCUSSION
Method Development and Optimization
Selection of chromatographic conditions and Optimization of Mobile Phase:
The main objective of the RP-HPLC method development is to rapid assay and related substances determination of
MPH in pharmaceutical formulation and the method should be able to determine assay (ASY) and related
substances (RS) in single run and should be accurate, reproducible, robust, stability indicating, filter
compatible, linear, free of interference from blank / placebo / impurities / degradation products and straightforward
enough for routine use in quality control laboratory.
The spiked solution of MPH (1000 µg/mL), Impurity-A (1 µg/mL) and Impurity-B (1 µg/mL) is subjected to
separation by RP-HPLC. Initially the separation of all compounds is studied using water as a mobile phase-A (MP-
A) and acetonitrile (ACN) as a mobile phase-B (MP-B) on a BES C18 (100x 40 i.d., 5 µm) using a Waters (HPLC)
system with the linear program. The flow rate of 1.5 mL/min is selected with regards to the backpressure and
analysis time as well. Various types of MP-A and MP-B are studied to optimize the method, which are summarized
with the associated observations in [Table 1].
Based on mobile phase selection experimental study, the optimized HPLC parameters are; flow rate1.5 mL/min;
column oven temperature 20°C; mixture of water, ACN, MeOH and buffer in the ratio of 50:20:30: v/v/v
respectively (pH adjusted 4.0 with Acetic acid). In order to achieve symmetrical peak shape of all substances and
more resolution between MPH and Imp-B different stationary phases are explored. Peak merging (Imp-B and MPH)
and broad peak shape of MPH is observed with an Acquity BHC C8 (100 x 2.1 mm, 4µm) column. Poor resolution
(Imp-B and MPH) and broad peak shape of MPH is observed with an Acquity BHC C18 (100 x 2.1 mm, 5 µm)
column.
Finally the desired separation with symmetrical peaks is obtained using HSSD waters symmetry C18 (100x 40 i.d.,
3.7 µm) column. Column oven temperature is also studied and found that 20°C is more appropriate with respect to
separation and peak shape. Based on compounds UV response, 210nm (for assay MPH) and 203nm (for related
substances) is found more appropriate for determination of MPH and its impurities from single run. MPH, Imp-A,
and Imp-B are well resolved from each other and there is no chromatographic interference observed due to blank
and placebo in a reasonable time of 6.0 minutes, optimized conditions and Overlaid specimen chromatograms of
assay study are presented in [Figure 2-4] and [Table 2]
[Figure 2: Expanded overlaid specimen chromatograms of blank, placebo and sample (at 230nm)]
6. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
611
[Figure 3: Overlaid specimen chromatograms of blank, placebo, diluted standard and spiked impurities along with analyte (at 205nm)]
[Figure 4: Overlaid specimen chromatograms of assay study (at 230nm)]
Analytical Parameters and Validation
After satisfactory development of the method it is subjected to method validation as per ICH guideline [9]. The
method is validated to demonstrate that it is suitable for its intended purpose by the standard procedure to evaluate
adequate validation characteristics (system suitability, accuracy, precision, linearity, robustness, solution stability,
filter compatibility and stability indicating capability).
Specificity
Specificity is the ability of the method to measure the analyte response in the presence of its potential impurities.
Forced degradation studies are performed to demonstrate selectivity and stability indicating capability of the
proposed RP-HPLC method. [Figure 2,3] are show that there is no any interferences at the RT (retention time) of
MPH due to blank, placebo and impurities. Stress studies are performed at concentration of 1000 µg/mL of MPH to
provide the stability indicating property and specificity of the proposed method. Spectral purity of MPH, Imp- A and
Imp-B are presented in [Figure 5-7]
Forced degradation studies are performed by the stress conditions acid hydrolysis [1 N HCl (3 mL),60°C, 1h, Figure
8], base hydrolysis [1N NaOH (3 mL), 60°C, 30 min, Figure 9], oxidative [30% H2O2 (3 mL), 60°C, 1h, Figure 10],
thermal [105°C, 6h, Figure 11], water hydrolysis [at 60 °C for 2h, Figure 12], and photolytic degradation [1.2
million Lux hours, Figure 13] to evaluate the ability of the proposed method to separate MPH from its degradation
products. Minor degradation products are observed when MPH is subjected to acid, heat, photolytic and hydrolytic
conditions.
Significant degradation is observed when the drug product is subjected to base hydrolysis, and slight degradation is
observed when the drug product is subjected to oxidative hydrolysis. The purity of the peaks obtained from the
stressed sample is verified using the PDA detector. The obtained purity angle is less than purity threshold for all the
stressed samples. An assay of samples is performed by comparison with reference standards, and the mass balance
[% assay + % known impurities + area % unknown impurities, at 205nm] for each of the stressed samples is
7. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
612
calculated. The results from forced degradation study and Peak purity plots of all stress condition samples are
presented in [Figures 5, 6, 7] and [Table 3].
[Figure 5: Spectral purity plots of MPH]
[Figure 6: Spectral purity plots of Impurity-A]
[Figure 7: Spectral purity plots of MPH, Imp-A and Imp-B]
8. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
613
[Figure 8: Overlaid chromatograms of acid hydrolysis study]
[Figure 9: Overlaid chromatograms of base hydrolysis study]
[Figure 10: Overlaid chromatograms of peroxide degradation study]
9. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
614
[Figure 11: Overlaid chromatograms of heat degradation study]
[Figure 12: Overlaid chromatograms of hydrolytic degradation study]
[Figure 13: Overlaid chromatograms of photolytic degradation study]
10. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
615
[Figure 14: Base hydrolysis]
[Figure 15: Water hydrolysis]
[Figure 16: Oxidative]
11. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
616
[Figure 17: Acid Hydrolysis]
[Figure 18: Thermal] [Figure 19: Photolytic]
[Figure 14-19 are the Obtained spectral purity plots of MPH in forced Degradation study]
System suitability
The percentage RSD of area counts of six replicate injections is below 1.0 % .The parameters all complied with the
acceptance criteria and system suitability is established. As seen from this data, the acceptable system suitability
parameters would be: resolution between Imp-B and MPH is not less than 1.5, theoretical plates is not less than
5000, tailing factor for MPH is not more than 2.0. Specimen chromatogram of system suitability solution and diluted
standard are presented in [Figure 20, 21] respectively and replicate in data [Table 4].
[Figure 20: Specimen chromatogram of system suitability solution]
Precision
The system precision of the related substance (at 203 nm) method is verified by injecting six replicate injections of a
standard solution contains MPH (1 µg/mL) and its two impurities of 1µg/mL of each. The RSD (%) of the peak
areas is calculated for each compound (system precision). Method precision experiments are conducted in six
individual preparations of MPH (1000 µg/mL) spiked with 1 µg/mL each of the impurities and the RSD (%) for area
12. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
617
percentage of each impurities is calculated. Precision of assay (at 210 nm) method is evaluated by performing six
(n=6) independent assays of MPH tablet at 1000 mg/mL level against a qualified working standard. The RSD (%) of
the six results is calculated. The intermediate precision of the assay and RS method is evaluated by different analyst,
instrument and day. The RSD (%) of peak area of MPH, Imp-A and Imp-B in system precision is within 1.0% .The
RSD (%) results of MPH and its impurities for precision and intermediate precision are presented below table. These
results confirmed the high precision of the method. Overlaid chromatogram for the assay standard preparation (at
210 nm), diluted standard preparation (at 203 nm), assay precision study and related substances precision study are
presented in [Figure 22-25] and [Table 4, 5].
[Figure 21: Specimen chromatogram of diluted standard solution]
[Figure 22: Overlaid chromatograms of replicate standard injection (at 230 nm)]
[Figure 23: Overlaid chromatograms of diluted standard solution (at 205 nm)]
13. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
618
[Figure 24: Overlaid chromatograms of assay precision study (at 230 nm)]
[Figure 25: Overlaid chromatograms of related substance precision study (at 205 nm)]
Accuracy
The accuracy of an analytical procedure expresses the closeness of agreement between the true value and the
observed value. The accuracy of the assay method for MPH is evaluated in triplicate (n=3) at the five concentrations
of 500, 750, 1000, 1250 and 1500 µg/mL (50, 75, 100, 125 and150%) of drug product, and the recovery is
calculated for each added (externally spiked)concentration. For all impurities, the recovery is determined in
triplicate (n=3) for 0.5, 0.75, 1.0, 1.25 and 1.5 µg/mL (50, 75, 100, 125 and 150%) of the analyte concentration
(1000 µg/mL) of the drug product, and the recovery of the impurities is calculated. The amount recovered is within
± 1.5% (for assay) and ± 5.0 % (for related substances) of amount added, which indicates that there is no
interference due to excipients present in pharmaceutical dosage forms. It is confirmed from results that the method is
highly accurate Overlaid specimen chromatograms of assay and related substances accuracy are presented in [Figure
26, 27] and [Table 6].
[Figure 26: Overlaid specimen chromatograms of assay accuracy study (at 230 nm)]
14. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
619
[Figure 27: Overlaid specimen chromatograms of accuracy study (related substances at 205 nm)]
Linearity:
The linearity of an analytical method is its ability to elicit test results that are directly proportional, or by a well-
defined mathematical transformation to the concentration of analyte in a sample within a given range. The detector
response linearity for Imp-A, Imp-B and MPH are assessed by injecting nine separately prepared solutions covering
the range of LOQ (0.1 µg/mL) to 2.0 µg/mL (LOQ, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.5 and 2.0 µg/mL) of the normal
analyte concentration (1µg/mL). For MPH assay the response function is determined by preparing standard solutions
at seven different concentration levels ranging from 500 to 1500 µg/mL (500, 700, 800, 1000, 1200,1400 and 1500
µg/mL). The correlation coefficients, slopes and y-intercepts of the calibration curve are determined. The correlation
coefficient obtained is greater than 0.999 in both cases. Overlaid specimen chromatograms of linearity study of
assay and related substances are presented in [Figure 28, 28] respectively. Linearity graph of Imp-A, Imp-B, MPH
(at 205nm) and MPH (at 230 nm) are presented in [Figure 28, 29] and [Table 7] respectively.
[Figure 28: Overlaid specimen chromatograms of linearity study (Assay)]
15. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
620
[Figure 29: Overlaid specimen chromatograms of linearity study (related substances)]
[Figure 30: Linearity curve of impurity-A]
[Figure 31: Linearity curve of impurity-B]
16. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
621
[Figure 32: Linearity curve of MPH for RS at 203 nm]
[Figure 33: Linearity curve of MPH at 210 nm]
Limit of detection (LOD) and limit of quantification (LOQ)
The LOD and LOQ for MPH and its impurities are determined at a signal to noise ratio of 3:1 and10:1, respectively,
by injecting a series of dilute solutions with known concentrations. Precision study is also carried out at the LOQ
level by injecting six (n=6) individual preparation and calculating the % RSD of the area for each impurity and
for MPH. The determined limit of detection, limit of quantification and precision at LOQ levels for MPH, Imp-A
and Imp-B are presented .Specimen chromatogram of LOD [Figure 34] And LOQ study is presented in [Figure 36]
and Overlaid chromatograms of LOD and LOQ precision study is presented in [Figure 37] and [Table 8].
[Figure 34: Spiked Specimen chromatogram of LOD for IMP-A, IMP-B, and MPH]
17. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
622
[Figure 35: Overlaid spiked chromatograms of LOD precision study for IMP-A, IMP-B, and MPH]
[Figure 36: Spiked Specimen chromatogram of LOQ for IMP-A, IMP-B, and MPH]
[Figure 37: Spiked Overlaid chromatograms of LOQ precision study for IMP-A, IMP-B, and MPH]
Robustness
To determine the robustness of the method, the experimental conditions are deliberately changed. The resolution of
MPH and imp-B is evaluated. The effect of change in flow rate ± 0.05mL/min (1.45 and 1.55 mL/min), column
oven temperature ± 5°C (15 and 25°C), mobile phase pH ± 0.2 units (3.8 and 4.2 pH) and mobile phase composition
± 10% (for ACN) are studied. During study other chromatographic conditions are kept same as per the experimental
section.
In all the deliberately varied chromatographic conditions, all of the analytes are adequately resolved, and the
order of elution remained unchanged. Robustness study obtained results are presented in Specimen chromatograms
18. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
623
of robustness study are presented in [Figure 38 - 41]. [Figure 38] indicate that USP resolution 1.56 is also adequate
for the peak separation in developed method data was represented in [Table 9].
[Figure 38: Specimen chromatograms of IMP-A, IMP-B, MPH robustness study (change in organic solvent ratio, ± 10%)]
[Figure 39: Specimen chromatograms of IMP-A, IMP-B, MPH robustness study (change in mobile phase pH)]
[Figure 40: Specimen chromatograms of IMP-A, IMP-B, MPH robustness study (column oven temperature)]
19. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
624
[Figure 41: Specimen chromatograms of IMP-A, IMP-B, MPH robustness study (flow rate variation)]
Ruggedness: The ruggedness can be evaluated by using different analysts but in the same chromatographic
conditions in different laboratories and different instruments. The result of ruggedness of developed method is stated
in table and the results are shown during by different analysts but in the same chromatographic condition of the test
solution wasn’t affected & in the accordance with the actual. The suitability parameters are also been found to be
good hence this method was concluded as rugged [Table 10].
Solution stability
Drug stability in pharmaceutical formulations is a function of storage conditions and chemical properties of the drug
and its impurities. Conditions used in stability experiments should reflect situations likely to be encountered during
actual sample handling and analysis. Stability data is required to show that the concentration and purity of the
analyte in the sample at the time of analysis corresponds to the concentration and purity of the analyte at the time of
sampling. MPH (1000 µg/mL) spiked solution (with 1 µg/mL of each impurity) is prepared in the diluent by leaving
the test solutions at room temperature. The spiked solution is re-analyzed at 12h and 24h time intervals, assay and
related substances are determinate for the compounds and compared against fresh sample. The sample solution does
not show any appreciable change in assay and related substances value when stored at ambient temperature up to
24hrs data are presented and the results from solution stability experiments confirmed that sample solution is stable
for up to 24h during assay and related substances determination. Standard solution is re-injected after 12 and 24h
time intervals and % RSD of all injected standard injections are calculated. Standard solution does not show any
appreciable change in % RSD (RSD for MPH is less than 1.0%) value when stored at ambient temperature up to
24h. Overlaid specimen chromatograms for sample solution stability of assay and related substances are presented in
[Figure 42-43] and [Table 11] respectively.
[Figure 42: Specimen chromatograms of MPH assay sample solution stability]
20. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
625
[Figure 43: Overlaid specimen chromatograms of related substance sample solution stability]
Filter compatibility
Filter compatibility is performed for PVDF 0.22 µm syringe filter (Millipore) and nylon 0.22 µm syringe filter
(Analytical Tech Labs). To confirm the filter compatibility in proposed analytical method, filtration recovery
experiment is carried out by sample filtration technique. Sample is filtered through both syringe filters. Assay and
related substances is determined (in µg/mL) and compared against centrifuged sample. The sample solution does not
show any significant changes in assay and related substances with respect to centrifuged sample. Filter compatibility
results are presented in which indicates that both syringe filters are compatible with sample solution. Overlaid
specimen chromatograms of assay and related substance test (filter compatibility) are presented in [Figure 48, 49] &
[Table 12], respectively.
[Figure 44: Overlaid specimen chromatograms of MPH assay filter compatibility study]
[Figure 45: Overlaid specimen chromatograms of related substance filter compatibility study]
21. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
626
Table 1: Summary of mobile phase optimization Trails and its observations
MP-A MP-B Observation
Water ACN Co-eluting peak of Imp-B and MPH
50% SAB ACN Co-eluting peak of Imp-B and MPH
20% SAB ACN:MeOH Poor resolution (Imp-B and MPH), USP tailing more than 2.0 for MPH
peak(30:50 v/v)
Mixture of water, ACN, MeOH N.A Poor resolution (Imp-B and MPH), USP tailing more than 3.0 for MPH
peakand THF [50:30:30 v/v/v ]
Mixture of water, ACN, MeOH NA Poor resolution (Imp-B and MPH), and broad peak shape of MPH
and TEA [40:30:30:0.1 v/v/v/v], pH adjusted
6.2with OPA
Mixture of ACN, MeOH NA Good Resolution (Imp-A,Imp-B, MPH) and good peak symmetrical
shape was achieved.and Buffer [50:20:30 v/v/v], pH adjusted 4.0 with
Acetic acid
USP = United state pharmacopoeia; ACN=Acetonitrile,MeOH=Methanol;AA=Acetic Acid OPA= Orthophosphoric acid; THF=Tetrahydrofuran
,SAB=Sodium Acetate Buffer
Table 2: Optimized Chromatographic Conditions
Parameters Description
Stationary Phase( Column ) HSSD waters symmetry C18 ( 100x 40 i.d., 3.7 µm)
Mobile phase Methanol:Acetonitrile:buffer (50:20:30 v/v/v) and pH adjusted 4.0 with acetic acid
pH 4
Flow rate 1.5 ml min-1
Run time (minutes) 6
Column temperature 20 ± 10
C
volume of Injection loop (µl) 20 µl
Detection wavelength 210 nm
Impurities & Drug RT (min) 2.349,2.792 & 3.168
Table 3: Summary of forced degradation results
Degradation condition Mass balance Purity
Angle Threshold Observation
Control sample 99.8 0.056 0.26 N.A.
Acidic hydrolysis 99.2 0.094 0.283 No degradation observed
Alkaline hydrolysis 98.5 0.129 0.328 Significant degradation observed
Oxidation 98.4 0.073 0.282 No significant degradation
Observed Water hydrolysis 99.5 0.056 0.25 No significant degradation
observed Thermal (solid) 100.1 0.054 0.26 No significant degradation
Photolytic 100.2 0.056 0.26 No significant degradation observed
Table 4: System suitability results (system precision, method precision and intermediate precision)
Test Parameters
Imp-A Imp-B MPH MPH
(1µg/mL) (1µg/mL) (1000µg/mL) (1 µg/mL)
System Precision Area % RSD 0.8 0.9 0.9 0.3
Presicison(n=6) USP Resolution NA NA NA NA
USP tailing 1.34 1.52 1.12 1.19
USP plate count 8831 7219 11975 11994
Intermediate precision USP resolution NA NA NA NA
(n=6) USP tailing 1.34 1.52 1.12 1.19
USP plate count 8831 7219 11975 11994
NA= Not applicable
Table 5: Precision (n=6) and Intermediate precision (n=6) results
Drug Substance Precisional Values Intermediate precision
Mean % % RSD Mean % % RSD
MPH (1000µg/mL) 99.3 0.9 99.5 1.1
Imp-A (1µg/mL) 0.098 2.4 0.101 2.3
Imp-B (1µg/mL) 0.103 2.7 0.097 2.6
22. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
627
Table 6: Accuracy results
Substance
At 50% (n=3) At 50% (n=3) At 50% (n=3) At 50% (n=3) At 50% (n=3)
%REC* %RSD %REC* %RSD %REC* %RSD %REC* %RSD %REC* %RSD
MPH (1000µg/mL) 100.6 0.8 100.1 0.4 99.4 1.1 99.7 0.7 99.1 1.3
MPH (1µg/mL) 95.5 3 97.2 2.1 97.8 3.5 96.8 2.3 98.7 3.3
Imp-A (1µg/mL) 95.3 4.6 98.3 2.8 103.1 3.5 98.7 3.1 99.5 4.2
Imp-B (1µg/mL) 102.5 3.5 101.2 3.5 104.5 4.4 101.3 2.7 97.5 3.8
*= Recovery
Table 7: Regression statistics
Compound Linearity range Correlation Linearity (Equation) Linearity
(µg/mL) coefficient (r2
) (Equation)
MPH 500 to 1500 0.9999 y=28306(x)-4E+06 1.452
MPH 0.1 to 2.0 0.9995 y =9700.4(x) + 16526 0.366
Imp-A 0.1 to 2.0 0.9998 y =33041(x)-208.53 -0.635
Imp-B 0.1 to 2.0 0.9992 y =9016.5(x) +16153 1.886
Table 8: Results of LOD, LOQ and LOQ precision (n=6)
MPH Impurity-A Impurity-B
LOD (µg/mL) 0.03 0.04 0.04
LOQ (µg/mL) 0.1 0.1 0.1
LOQ precision (% RSD) 4.5 4.9 5.7
Table 9: Evaluation data results of Robustness study of IMP-A, IMP-B, MPH
Condition Parameters Imp-A Imp-B MPH
USP resolution -- -- 2.35
Retention time in min 2.349 2.792 3.162
USP tailing 1.28 1.49 1.17
USP plate count 8829 7215 11968
Normal methodology Assay % w/w 0.097 0.101 99.4
USP resolution -- -- 2.29
Retention time in min 2.801 3.391 3.789
USP tailing 1.29 1.46 1.17
USP plate count 9281 7871 7990
At flow rate 1.45 mL/min Assay % w/w 0.096 0.102 99.3
USP resolution -- -- 2.48
Retention time in min 2.008 2.412 2.714
USP tailing 1.32 1.49 1.17
USP plate count 9083 9298 7786
At flow rate 1.55 mL/min Assay % w/w 0.096 0.103 99.3
USP resolution -- -- 2.75
Retention time in min 2.458 2.985 3.381
USP tailing 1.34 1.39 1.16
USP plate count 9820 9889 8380
At 15°C column oven temp Assay % w/w 0.098 0.102 99.5
USP resolution -- -- 2.16
Retention time in min 2.239 2.654 2.951
USP tailing 1.26 1.37 1.26
USP plate count 9081 7545 7126
At 25°C column oven temp Assay % w/w 0.097 0.103 98.8
USP resolution -- -- 1.69
Retention time in min 2.018 2.435 2.652
USP tailing 1.29 1.39 1.12
USP plate count 7379 8964 7536
At mobile phase pH 3.8 Assay % w/w 0.098 0.101 99.4
USP resolution -- -- 2.38
Retention time in min 2.358 2.849 3.204
USP tailing 1.29 1.36 1.18
USP plate count 8649 8138 7848
At mobile phase pH 4.2 Assay % w/w 0.097 0.103 99.4
USP resolution -- -- 2.74
Retention time in min 2.788 3.302 3.875
USP tailing 1.14 1.43 1.3
USP plate count 9969 10774 8252
23. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
628
Mobile phase [-10% ACN] Assay% w/w 0.098 0.102 99.5
Mobile phase [+10% ACN]
USP Resolution 1.53
Retention time in min 2.012 2.429 2.625
USP tailing 1.4 1.53 1.38
USP plate count 7247 8758 7436
Assay % w/w 0.099 0.103 99.7
[Table 10: Evaluation data of Ruggedness study of IMP-A, IMP-B, and MPH]
ID Precisions No. of Injections
IMP-A IMP-B MPH
Peak Area RT Peak Area RT Peak Area RT
Analyst 1 897912 2.347 188537 2.79 311221 3.167
ID Precision - 1 2 902826 2.349 188577 2.792 311666 3.165
3 903754 2.346 190256 2.794 316841 3.167
Analyst 1 901972 2.345 189433 2.791 316709 3.165
ID Precision - 2 2 899897 2.347 189558 2.792 317747 3.167
3 900583 2.346 189746 2.792 318175 3.167
MEAN 901157.3 2.346 189351.17 2.792 315393 3.164
STDEV 2127.971 0.002 676.209 0.003 3111.45 0.005
% RSD 0.236138 0.123 0.357 0.121 0.986 0.121
Table 11 : Solution stability results of IMP-A, IMP-B, and MPH
Compound 0hrs 12hrs 24hrs 48 hrs
MPH (1000µg/mL) 1005 1004 1003 1002
IMP-A (1µg/mL) 1.003 1.007 1.008 1.006
IMP-B (1µg/mL) 0.975 0.967 0.978 0.969
Table 12 : Filter compatibility results of IMP-A, IMP-B, and MPH
Compound Ultra Centrifugation PVDF filter membrane 0.22µm Nylon membrane filter 0.22µm
MPH (1000µg/mL) 1005 1004 1003
IMP-A (1µg/mL) 0.951 0.961 0.964
IMP-B (1µg/mL) 0.985 0.972 0.981
CONCLUSION
The rapid isocratic RP-HPLC method is developed for quantitative and related substances analysis of MPH in
pharmaceutical formulation. Satisfactory results are obtained from validation of the method. The run time (6 min)
enabled rapid determination of MPH. This method exhibited an excellent performance in terms of sensitivity and
speed. This stability-indicating method can be applied for the routine analysis of production samples and to check
the stability of MPH in bulk drug and formulation. Moreover, it can be applied for determination of assay, blend
uniformity, content uniformity and in vitro dissolutions of pharmaceutical products, where sample load is higher and
high throughput is essential for faster delivery of results
Acknowledgements
The author wish to acknowledge the Bright Labs and KDPL Pharmaceuticals,Hderabad for providing gratis samples
of Impurities and infrastructural facility to carry out this work and also special thanks to my mentor
Dr.N.Kannappan for his excellent advise on this work.
REFERENCES
[1] B Hechman; B Greenfield. J.Expert Rev Neurother., 2005, 5(2), 107-121.
[2] BE Leonard; MC Cartan; DJ White; DJ King. J. Human Psychology., 2004, 19,151-80.
[3]. A Gilmore; R Milne. J .Pharmaco Drug Saf., 2001, 10(2), 85–94.
[4] TF Mott; L Leach; L Johnson. J.of Family Practice., 2004, 53(8): 659–61.
[5] BA Faraj; ZH Israeli; JM Perel. J.Pharmaco Exp Ther., 1974, 23(6) 191-199.
[6] MF Bartlett; HP Egger. Academic J. Exp Biol., 1972, 31(4), 537.
[7] PK Capp; PL Pearl. J.Rev Neurother., 2005, 5(3): 325–31.
[8] H Shepard; T Sein; W Rodegker; A Plummer. J.Toxicol Appi Pharmacology., 1960 2(3), 353-356.
[9] A Secilir. J.Chromatography A ., 2013,23(4),22-28.
[10] MP Sharon. J.Chromatography A., 2012, 23(2), 20-28.
[11] CF Maria; ZM Lepnardo; GR Luciana; PL Renata. J. Chroma Suppl.,2009,69(3),143-148.
[12] SJ Soldin;YP Chan; BM Hill; JM Swanson. Academic J. Child Psych., 1982, 21(2), 19-26.
24. Ch. Naveen Kumar and N. Kannappan J. Chem. Pharm. Res., 2015, 7(5):606-629
______________________________________________________________________________
629
[13] B Schubert; KN Bent. J. Chem Scand., 1970, 24(4), 433.
[14] J Galhod; BJ shon; C Pintauro. J. Pharm. Sci., 1977, 66(2), 86-89.
[15] RM Milberg; KL Rinehart; RL Sprague; EK Sleator. J.Biomed Mass Spectrum., 1975, 2 (2)223-228.
[16] R Wells; KB Hammond; D Rodgerson. J. Clin Medicine., 1974, 20(4), 440-442.