Integrated  Energy  is the working title for a Building Physics consultancy providing services to Architects and builders to deliver low energy low impact building without the risk.
Who are we?   Dr Kirk Shanks  BEng (Hons), MSc Arch, PhD   Frank Cooney  B.Arch MRIAI Pat Barry  Dip.Arch,Msc,MRIAI,Dip.Proj.Man Archie O’Donnell  Dip.Arch,Tech,BSc Reg+Urban Plan Frank Cooney  is principle of Cooney Architects. He was Project manager on the pioneering 1992 Green building in Dublins Temple Bar. He recently received a Green Apple award for his passive house approach renovation of an 1830‘s farmhouse. His practice specialises in Education and large scale residential. Dr. Kirk Shanks is the senior researcher in the School of Architecture in the Dublin Institute of Technology, founder of the Research in Sustainable Environments Unit (RiSE) he has been a key mover in creating new research programmes and groups.  Pat Barry is an Architect with 20years experience and BREEAM consultant. He has worked extensivly in Northern Ireland with TODD Architects. He is currently an initiator of the Irish Green Building Council and a proponent of whole systems sustainability frameworks for Ireland. Pat designs Passive house projects for multi residence schemes. Archie O‘Donnell is an Architectural consultant advising on cost effective methods of delivering Passive and low energy Buildings. He has air tested houses as low 0.22 and 0.25 air changes for passive houses. He is also a planning consultant secialising in environmental assessment of masterplanning
 
Commercial Mixed use Vets practice, doctors surgery, 2 Apartments.  designed as conventional, built as near passive. Vets and doctors surgery 16kWh/m2 Apartments 14kWh/m2 Air test 0.9m2/hr/m2 Passive Renovation Renovated to 14kWh/m2 Air test 0.65m2/hr/m2 Energy-plus standard
Passive Schools Approach – St Laurence’s NS BREEAM Education
Low energy School Timber frame high spec.
2015 Carbon Neutral Passive Renovation - conservation Renovated to 20 kWh/m2 Air test 1.0 m2/hr/m2 Seasonal Storage Cold bridge – original details Cold bridge – improved details
2015 Carbon Neutral
Passive House Timber frame high spec.
3 litre house Self builder spec.
A rated house Local Authority spec.  Passive design approach Cooney Architects. Solar Aspect masterplanning
A rated house Local Authority spec. Option 1 Terracotta
A rated house Local Authority spec. Thermal Bridge
A rated house Local Authority spec.  Surface temperature
A rated house Local Authority spec. Option 2 EPS external render and AAC
A rated house Local Authority spec. Option 2 Thermals
A rated house Local Authority spec. Option 2 Cold bridge Calculation
     A rated house Local Authority spec. Option 2 Condensation risk analysis
     A rated house Local Authority spec. Option 2 Condensation risk - location
     A rated house Local Authority spec. Option 2 Condensation risk location 1
     A rated house Local Authority spec. Option 2 Condensation risk location 2
Airtightness – Thermal Imaging
2015 Carbon Neutral 3 litre House Heating Schematic
Airtightness – Thermal Imaging
 
Passive Principles, PHPP , BREEAM PHPP, Daylight analysis, Shading analysis, Specification Thermal Bridging, Specification airtightness,PHPP,WUFI Detail supervision, tool box talks ` Air test, remediation reports OUR SERVICES We provide expertise in designing Passive houses and commercial buildings. BREEAM buildings and communities. We specialise in modelling and analysis of construction detailing to eliminate air leakage and thermal bridging. We can provide consultants to augment your sustainability consultants expertise and assist in the delivery of better buildings based on evidence led decision making

Integrated Energy Presentation

  • 1.
  • 2.
    Integrated Energy is the working title for a Building Physics consultancy providing services to Architects and builders to deliver low energy low impact building without the risk.
  • 3.
    Who are we? Dr Kirk Shanks BEng (Hons), MSc Arch, PhD Frank Cooney B.Arch MRIAI Pat Barry Dip.Arch,Msc,MRIAI,Dip.Proj.Man Archie O’Donnell Dip.Arch,Tech,BSc Reg+Urban Plan Frank Cooney is principle of Cooney Architects. He was Project manager on the pioneering 1992 Green building in Dublins Temple Bar. He recently received a Green Apple award for his passive house approach renovation of an 1830‘s farmhouse. His practice specialises in Education and large scale residential. Dr. Kirk Shanks is the senior researcher in the School of Architecture in the Dublin Institute of Technology, founder of the Research in Sustainable Environments Unit (RiSE) he has been a key mover in creating new research programmes and groups. Pat Barry is an Architect with 20years experience and BREEAM consultant. He has worked extensivly in Northern Ireland with TODD Architects. He is currently an initiator of the Irish Green Building Council and a proponent of whole systems sustainability frameworks for Ireland. Pat designs Passive house projects for multi residence schemes. Archie O‘Donnell is an Architectural consultant advising on cost effective methods of delivering Passive and low energy Buildings. He has air tested houses as low 0.22 and 0.25 air changes for passive houses. He is also a planning consultant secialising in environmental assessment of masterplanning
  • 4.
  • 5.
    Commercial Mixed useVets practice, doctors surgery, 2 Apartments. designed as conventional, built as near passive. Vets and doctors surgery 16kWh/m2 Apartments 14kWh/m2 Air test 0.9m2/hr/m2 Passive Renovation Renovated to 14kWh/m2 Air test 0.65m2/hr/m2 Energy-plus standard
  • 6.
    Passive Schools Approach– St Laurence’s NS BREEAM Education
  • 7.
    Low energy SchoolTimber frame high spec.
  • 8.
    2015 Carbon NeutralPassive Renovation - conservation Renovated to 20 kWh/m2 Air test 1.0 m2/hr/m2 Seasonal Storage Cold bridge – original details Cold bridge – improved details
  • 9.
  • 10.
    Passive House Timberframe high spec.
  • 11.
    3 litre houseSelf builder spec.
  • 12.
    A rated houseLocal Authority spec. Passive design approach Cooney Architects. Solar Aspect masterplanning
  • 13.
    A rated houseLocal Authority spec. Option 1 Terracotta
  • 14.
    A rated houseLocal Authority spec. Thermal Bridge
  • 15.
    A rated houseLocal Authority spec. Surface temperature
  • 16.
    A rated houseLocal Authority spec. Option 2 EPS external render and AAC
  • 17.
    A rated houseLocal Authority spec. Option 2 Thermals
  • 18.
    A rated houseLocal Authority spec. Option 2 Cold bridge Calculation
  • 19.
        A rated house Local Authority spec. Option 2 Condensation risk analysis
  • 20.
        A rated house Local Authority spec. Option 2 Condensation risk - location
  • 21.
        A rated house Local Authority spec. Option 2 Condensation risk location 1
  • 22.
        A rated house Local Authority spec. Option 2 Condensation risk location 2
  • 23.
  • 24.
    2015 Carbon Neutral3 litre House Heating Schematic
  • 25.
  • 26.
  • 27.
    Passive Principles, PHPP, BREEAM PHPP, Daylight analysis, Shading analysis, Specification Thermal Bridging, Specification airtightness,PHPP,WUFI Detail supervision, tool box talks ` Air test, remediation reports OUR SERVICES We provide expertise in designing Passive houses and commercial buildings. BREEAM buildings and communities. We specialise in modelling and analysis of construction detailing to eliminate air leakage and thermal bridging. We can provide consultants to augment your sustainability consultants expertise and assist in the delivery of better buildings based on evidence led decision making