An explanation of the basic legislative requirements and how these are achieved using impulse ventilation
Application of impulse ventilation, both for carbon monoxide and for smoke clearance or smoke control
The advantages of impulse ventilation over traditional ducted extract systems
Use of CFD
Control systems used: carbon monoxide and heat detection systems
How impulse ventilation can be used to control smoke movement, allowing smoke control to be used, as part of a fire strategy, to compensate for the relaxation of other legislative requirements, e.g. travel distances
A case history of a particular project where travel distances were relaxed using impulse ventilation designed for smoke control
An explanation of how this project was validated using CFD and live fire tests
EXD Hazardous Area Barrier Glands from Flexicon are manufactured from nickel plated brass with a nylon seal, to an IP rating of IP66, IP67, IP68 (5bar) and IP69K - ATEX certified barrier glands are suitable for use with Flexicon flexible conduit (liquid tight types) in Zone 1, Zone 2, Zone 21 and Zone 22.
EXD flameproof barrier glands are suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas, when used with the Flexicon range of liquid-tight flexible conduits.
Hazardous Area Barrier Gland (ATEX) Certified
• High mechanical strength
• Suitable for threaded entries
• Operating temperature of -60oC to +85oC
• Two-part epoxy solid-setting putty, gloves and mixing instructions
ATEX barrier glands for indoor or outdoor use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with all types of cables housed in Liquid Tight flexible conduit systems. ATEX barrier glands are suitable for knockouts or threaded entries. Nickel plated brass compression fitting comprising of body, nut, earthing ferrule, nylon compression seal and compound barrier. The compound barrier seals around the cable conductors for hazardous area cable glanding on conduit systems. The earthing ferrule is manufactured in machined nickel plated brass to facilitate easy assembly and re-use. Also ensures high mechanical strength and electrical continuity.
Flexicon flexible conduits with ATEX flameproof barrier glands (LTP-EXD flameproof barrier glands) are suitable for use with Flexicon LTP, LTPHC, LTPUL, LTPSS and LTPPU conduits.
An explanation of the basic legislative requirements and how these are achieved using impulse ventilation
Application of impulse ventilation, both for carbon monoxide and for smoke clearance or smoke control
The advantages of impulse ventilation over traditional ducted extract systems
Use of CFD
Control systems used: carbon monoxide and heat detection systems
How impulse ventilation can be used to control smoke movement, allowing smoke control to be used, as part of a fire strategy, to compensate for the relaxation of other legislative requirements, e.g. travel distances
A case history of a particular project where travel distances were relaxed using impulse ventilation designed for smoke control
An explanation of how this project was validated using CFD and live fire tests
EXD Hazardous Area Barrier Glands from Flexicon are manufactured from nickel plated brass with a nylon seal, to an IP rating of IP66, IP67, IP68 (5bar) and IP69K - ATEX certified barrier glands are suitable for use with Flexicon flexible conduit (liquid tight types) in Zone 1, Zone 2, Zone 21 and Zone 22.
EXD flameproof barrier glands are suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas, when used with the Flexicon range of liquid-tight flexible conduits.
Hazardous Area Barrier Gland (ATEX) Certified
• High mechanical strength
• Suitable for threaded entries
• Operating temperature of -60oC to +85oC
• Two-part epoxy solid-setting putty, gloves and mixing instructions
ATEX barrier glands for indoor or outdoor use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with all types of cables housed in Liquid Tight flexible conduit systems. ATEX barrier glands are suitable for knockouts or threaded entries. Nickel plated brass compression fitting comprising of body, nut, earthing ferrule, nylon compression seal and compound barrier. The compound barrier seals around the cable conductors for hazardous area cable glanding on conduit systems. The earthing ferrule is manufactured in machined nickel plated brass to facilitate easy assembly and re-use. Also ensures high mechanical strength and electrical continuity.
Flexicon flexible conduits with ATEX flameproof barrier glands (LTP-EXD flameproof barrier glands) are suitable for use with Flexicon LTP, LTPHC, LTPUL, LTPSS and LTPPU conduits.
Fire Hydrant System/Sprinkler System Fire Fighting Systems Fire Hydrant Syst...RajyogFireServicesPv
Fire Hydrant System,System Information,Operational Information,Fire Alarm System ......
Being one of the oldest but yet the most effective and common fire fighting solution, a well designed and a well laid out Hydrant System forms the backbone of the entire fire fighting system. It comprises of heavy duty above & underground piping with accessories. External and Fire Escape Hydrant valves are provided at every strategic location. A fire hydrant is a pipe that allows water to flow from a water main with the control of a valve in order to put out a fire.
A fire sprinkler system is an active fire protection measure, consisting of a water supply system, providing adequate pressure and flow rate to a water distribution piping system, onto which fire sprinklers are connected
An automatic sprinkler system is intended to detect, control and extinguish a fire, and warn the occupants of occurrence of fire. The installation comprises fire pumps, water storage tanks, control valve sets, sprinkler heads, flow switches, pressure switches, pipe work and valves. The system operates automatically without human intervention.
New York City Department of Buildings Filing rep course_207Safe Rise
Course 207 (Download Course Materials)
Fire Alarm Plan Examination Procedure
Sprinkler and Standpipe
Fire Extinguishing Systems
Codes and Laws Fire Protection 2008 Building Code
2014 Codes Fire Protection Systems
DETECTORS
Thermal detectors thermal detectors are temperature-activated sensors to initiate an alarm.
Fixed-temperature type
Rate-of-rise (ror) type
Combination type
Smoke detector it is a device that senses smoke. They are quicker to respond than thermal detectors.
Photoelectric type
Ionization type
Flame detector It is used to detect the direct radiation of a flame in the visible,infrared, and ultraviolet ranges of the spectrum.
Infrared detector
Ultraviolet detector
Photoelectric detector
Flame flicker detector
AFiredetectionandalarmsystemisnumberofdevicesworkingtogethertodetectandwarn
people through visual and audio appliances when smoke,fire,CO or other emergencies are present.
CAR PARK VENTILATION CFD SERVICES - CAEDTECHrajarathnam
CAED TECH offers complete design for car park ventilation system. Our services are as follows.
1. Best Location of Fresh & Exhaust air shaft along with its sizes to maintain proper velocity all over basement.
2. Selection and Quantify of main Exhaust air & Fresh air supply Axial Flow Fan.
3. Selection and Quantify of Jet Fan.
4. Quantify and located the Electrical Panel to reduce the Electrical accessories like power & control Cable, Cable Tray, Conduit, Earth wire etc.
5. Estimations of above Electrical accessories.
6. Technical Specification of main equipments.
7. Bill of Quantity (BOQ) of CPV System.
8. Budgetary Cost of CPV System.
9. Drawings of CPV System.
Fresh & Exhaust air shaft sectional details along with Axial fan mounting arrangement and Suction & discharge Louver sizes.
Typical Jet Fan mounting arrangement.
Cable Tray layout drawing.
10. Login of operation for enter CPV system.
A região da 24 de Outubro com Nova York é privilegiada em Porto Alegre. Além de ser uma área que conservou sua riqueza arquitetônica ao mesmo tempo em que adaptou perfeitamente à modernidade, ela tem uma característica que nenhuma outra tem: a centralidade em bairros tão vivos como o Moinhos de Vento, Auxiliadora, Mont Serrat, Bela vista e Higienópolis.
A união de todas essas características forma um lugar único. Uma experiência diferente para quem quer morar ou trabalhar em meio a m clima charmoso, perto de tudo que precisa no dia a dia e com acesso rápido a qualquer ponto da cidade.
• Segurança 24h
• Recepção
• Alarme de incêndio
• Circuito interno de TV com câmeras em todos os acessos
• Controle de acesso com catracas automatizadas
• Elevadores e escadas exclusivos de acesso aos estacionamentos
ESTRUTURA DO CONDOMÍNIO E DAS SALAS:
• Torres com esperas para sistemas de automação nas unidades
• 2 salas de reuniões e auditório
• Espera para segundo ponto hidráulico
• Gerador de energia (1 elevador e circulação dos pavimentos)
• Áreas comuns entregues equipadas e mobiliadas
• Acabamentos de alto padrão
• Wi-fi nas áreas comuns
• Lobby com pé direito duplo
Previsão de entrega para outubro de 2016.
Informações:
http://www.foxterciaimobiliaria.com.br/imovel/105740/comercial-porto-alegre-independencia-sala-trend-24-offices-zona-norte?corretor=joao-guedes
Fire Hydrant System/Sprinkler System Fire Fighting Systems Fire Hydrant Syst...RajyogFireServicesPv
Fire Hydrant System,System Information,Operational Information,Fire Alarm System ......
Being one of the oldest but yet the most effective and common fire fighting solution, a well designed and a well laid out Hydrant System forms the backbone of the entire fire fighting system. It comprises of heavy duty above & underground piping with accessories. External and Fire Escape Hydrant valves are provided at every strategic location. A fire hydrant is a pipe that allows water to flow from a water main with the control of a valve in order to put out a fire.
A fire sprinkler system is an active fire protection measure, consisting of a water supply system, providing adequate pressure and flow rate to a water distribution piping system, onto which fire sprinklers are connected
An automatic sprinkler system is intended to detect, control and extinguish a fire, and warn the occupants of occurrence of fire. The installation comprises fire pumps, water storage tanks, control valve sets, sprinkler heads, flow switches, pressure switches, pipe work and valves. The system operates automatically without human intervention.
New York City Department of Buildings Filing rep course_207Safe Rise
Course 207 (Download Course Materials)
Fire Alarm Plan Examination Procedure
Sprinkler and Standpipe
Fire Extinguishing Systems
Codes and Laws Fire Protection 2008 Building Code
2014 Codes Fire Protection Systems
DETECTORS
Thermal detectors thermal detectors are temperature-activated sensors to initiate an alarm.
Fixed-temperature type
Rate-of-rise (ror) type
Combination type
Smoke detector it is a device that senses smoke. They are quicker to respond than thermal detectors.
Photoelectric type
Ionization type
Flame detector It is used to detect the direct radiation of a flame in the visible,infrared, and ultraviolet ranges of the spectrum.
Infrared detector
Ultraviolet detector
Photoelectric detector
Flame flicker detector
AFiredetectionandalarmsystemisnumberofdevicesworkingtogethertodetectandwarn
people through visual and audio appliances when smoke,fire,CO or other emergencies are present.
CAR PARK VENTILATION CFD SERVICES - CAEDTECHrajarathnam
CAED TECH offers complete design for car park ventilation system. Our services are as follows.
1. Best Location of Fresh & Exhaust air shaft along with its sizes to maintain proper velocity all over basement.
2. Selection and Quantify of main Exhaust air & Fresh air supply Axial Flow Fan.
3. Selection and Quantify of Jet Fan.
4. Quantify and located the Electrical Panel to reduce the Electrical accessories like power & control Cable, Cable Tray, Conduit, Earth wire etc.
5. Estimations of above Electrical accessories.
6. Technical Specification of main equipments.
7. Bill of Quantity (BOQ) of CPV System.
8. Budgetary Cost of CPV System.
9. Drawings of CPV System.
Fresh & Exhaust air shaft sectional details along with Axial fan mounting arrangement and Suction & discharge Louver sizes.
Typical Jet Fan mounting arrangement.
Cable Tray layout drawing.
10. Login of operation for enter CPV system.
A região da 24 de Outubro com Nova York é privilegiada em Porto Alegre. Além de ser uma área que conservou sua riqueza arquitetônica ao mesmo tempo em que adaptou perfeitamente à modernidade, ela tem uma característica que nenhuma outra tem: a centralidade em bairros tão vivos como o Moinhos de Vento, Auxiliadora, Mont Serrat, Bela vista e Higienópolis.
A união de todas essas características forma um lugar único. Uma experiência diferente para quem quer morar ou trabalhar em meio a m clima charmoso, perto de tudo que precisa no dia a dia e com acesso rápido a qualquer ponto da cidade.
• Segurança 24h
• Recepção
• Alarme de incêndio
• Circuito interno de TV com câmeras em todos os acessos
• Controle de acesso com catracas automatizadas
• Elevadores e escadas exclusivos de acesso aos estacionamentos
ESTRUTURA DO CONDOMÍNIO E DAS SALAS:
• Torres com esperas para sistemas de automação nas unidades
• 2 salas de reuniões e auditório
• Espera para segundo ponto hidráulico
• Gerador de energia (1 elevador e circulação dos pavimentos)
• Áreas comuns entregues equipadas e mobiliadas
• Acabamentos de alto padrão
• Wi-fi nas áreas comuns
• Lobby com pé direito duplo
Previsão de entrega para outubro de 2016.
Informações:
http://www.foxterciaimobiliaria.com.br/imovel/105740/comercial-porto-alegre-independencia-sala-trend-24-offices-zona-norte?corretor=joao-guedes
2010 YAMAHA XT1200Z SUPER TENERE Service Repair Manualuksjemm
This is the Highly Detailed factory service repair manual for the2010 YAMAHA XT1200Z SUPER TENERE, this Service Manual has detailed illustrations as well as step by step instructions,It is 100 percents complete and intact. they are specifically written for the do-it-yourself-er as well as the experienced mechanic.2010 YAMAHA XT1200Z SUPER TENERE Service Repair Workshop Manual provides step-by-step instructions based on the complete dis-assembly of the machine. It is this level of detail, along with hundreds of photos and illustrations, that guide the reader through each service and repair procedure. Complete download comes in pdf format which can work under all PC based windows operating system and Mac also, All pages are printable. Using this repair manual is an inexpensive way to keep your vehicle working properly.
Service Repair Manual Covers:
General information
Specifications
Periodic checks and adjustments
Chassis
Engine
Cooling system
Fuel system
Electrical system
Troubleshooting
File Format: PDF
Compatible: All Versions of Windows & Mac
Language: English
Requirements: Adobe PDF Reader
NO waiting, Buy from responsible seller and get INSTANT DOWNLOAD, Without wasting your hard-owned money on uncertainty or surprise! All pages are is great to have2010 YAMAHA XT1200Z SUPER TENERE Service Repair Workshop Manual.
Looking for some other Service Repair Manual,please check:
https://www.aservicemanualpdf.com/
Thanks for visiting!
8
2007 Yamaha XV19CTMWC Stratoliner Service Repair Manualjksfnmsme
This is the Highly Detailed factory service repair manual for the2007 YAMAHA XV19CTMWC STRATOLINER, this Service Manual has detailed illustrations as well as step by step instructions,It is 100 percents complete and intact. they are specifically written for the do-it-yourself-er as well as the experienced mechanic.2007 YAMAHA XV19CTMWC STRATOLINER Service Repair Workshop Manual provides step-by-step instructions based on the complete dis-assembly of the machine. It is this level of detail, along with hundreds of photos and illustrations, that guide the reader through each service and repair procedure. Complete download comes in pdf format which can work under all PC based windows operating system and Mac also, All pages are printable. Using this repair manual is an inexpensive way to keep your vehicle working properly.
Service Repair Manual Covers:
General Information
Specifications
Periodic Checks and Adjustments
Chassis
Engine
Fuel System
Electrical System
Troubleshooting
File Format: PDF
Compatible: All Versions of Windows & Mac
Language: English
Requirements: Adobe PDF Reader
NO waiting, Buy from responsible seller and get INSTANT DOWNLOAD, Without wasting your hard-owned money on uncertainty or surprise! All pages are is great to have2007 YAMAHA XV19CTMWC STRATOLINER Service Repair Workshop Manual.
Looking for some other Service Repair Manual,please check:
https://www.aservicemanualpdf.com/
Thanks for visiting!