This document discusses Dwyer Instruments' humidity and temperature transmitters, including their various mounting configurations, sensor specifications, applications, and contact information for ordering or getting more information. The transmitters can be mounted in ducts, on walls, outdoors, or remotely and measure humidity, temperature, or both for various HVAC and building automation applications.
4. Humidity Sensor Specifications
► Accuracy
2% Models: ± 2% @ 10-90% RH
3% Models: ± 3% @ 20-80% RH
► Temperature Limits
Temperature Range: -40 to 140° F (-40 to
60˚C)
Compensated Temperature Range: -4 to 140° F
(-20 to 60˚C)
5. Wall Mount Humidity
► Wall Mount
Optional Remote or Integral LCD
Display
Universal Current / Voltage Output
for Humidity and Temperature
Resistive Temperature Outputs
Available
Replaceable Sensors
Well Ventilated for More Accurate
Measurements
6. Duct Mount Humidity
► Duct Mount
Weather resistant PBT Construction
Dual Temperature & RH Output
► Optional Display Reads Both Temperature & Relative
Humidity
Field Replaceable Sensor Cap or Filter
Twist-Off Cover, No Screws
Available With Sintered Filter
7. Outside Air Humidity
► Outdoor Air
NEMA 4X / IP65 Housing
Field Replaceable Sensor
Multiple Knock Outs for Conduit
Screws Anchored Inside Lid Top
Available with Stainless Steel
Sintered Filter
8. Remote Mount and Compact
Housing
► Remote Sensor (Series RH-R)
Low Profile Sensor
Protect Electronics From High
Temperatures
Field Replaceable Cable & Sensor
► Compact Housing (Series WHT)
Sintered Filter Protects Sensor
Watertight Housing
Integral Mounting Ears
9. Hazardous Area Transmitters
► Explosion-Proof (Series HHT-E)
FM Approved for Class I Div 1 Groups B,C,D,
Class II Div 1 Groups E,F,G, Class III Div 1
Humidity Transmitter Only
Optional LCD Display
► Intrinsically-Safe (Series HHT-I)
Must be Used with KFD0-SCS-EX1.55 Galvanic
Isolator
FM Approved for Class I Div 1 Groups B,C,D,
Class II Div 1 Groups E,F,G, Class III Div 1 T4
Humidity or Humidity / Temperature Model
10. Applications
► Wall Mount
Humidity /
Temperature
Transmitter
mounted in a room
sends signal to
controller on VAV
system to adjust
amount of air flow
supplied to the
space.
11. Applications
► Duct Mount
Humidity /
Temperature
Transmitter
monitors the
humidity of the
supply air after a
humidifier and the
humidity in return
duct for economizer
applications
12. Applications
► Outside Air
Humidity /
Temperature
transmitter
used to
determine if
additional hot or
cold water needs
to feed AHU
13. Questions
To order a free catalog or for more information contact;
Dwyer Instruments, Inc., P.O. Box 373,
Michigan City, IN., 46361
Telephone: (800) 872-9141 or (219) 879-8000
Fax: (219) 872-9057
Internet address: www.dwyer-inst.com
E-mail: info@dwyer-inst.com