The Series RSMC StabiliSENSE™ Critical Room Status Monitor is designed for critical low differential pressure applications that require stringent pressure monitoring and alarming. It can be configured to monitor positive or negative pressure in clean rooms, hospital isolation rooms, school nurses offices, laboratories, and vivariums. The RSMC is a complete system with a touchscreen graphical user interface which enables access to pressure, humidity, temperature, air change, security, door status, calibration, and alarm setup. The graphical display color changes allow a clear determination of when the parameters are operating within the acceptable range (green), caution range (yellow), or have gone outside the acceptable operating range (red). The RSMC StabiliSENSE™ critical room status monitor comes standard with BACnet MS/TP and Modbus® RTU communications.
To learn more or order, please visit https://www.dwyer-inst.com/Product/SeriesRSMC#literature
2. ● What is it?
○ The Series RSMC StabiliSENSE™ critical room status monitor is a touch screen monitor that is
designed for low differential pressure applications that require pressure monitoring and alarming
○ The RSMC is intended for status indication of pressure, relative humidity, temperature, air change per
hour (ACH), and/or door status in clean areas
General Information
StabiliSENSE ™ Critical Room Status Monitor
3. Applications
● HVAC and process room monitoring
○ Primarily used for visual indication of room status
● Applications
○ Hospital isolation rooms
○ School nurse offices
○ Operating rooms
○ Clean rooms
○ Research labs
○ Vivariums
○ Pharmaceutical
○ Semiconductor
StabiliSENSE ™ Critical Room Status Monitor
4. Key Benefits / Features
StabiliSENSE ™ Critical Room Status Monitor
Modbus®is a registered trademark of Schneider Automation, Inc.
5. Key Benefits / Features
● Long-term stable pressure measurements
○ Less routine maintenance for re-calibration due to sensor drifting
● Capable of monitoring up to four user-defined parameters
○ Pressure, relative humidity, temperature, air changes per hour (ACH), and/or door status
● Slim mounting depth of 1.25 in (31.74 mm)
○ Ensures flush mounting capability for space-constrained areas
● Visual color changing display incorporates color status indication
○ Displays as green for good, orange for warning, and red for alarm
○ Provides immediate local alert so corrective action can be taken quickly
● BACnet and Modbus®communications compatible
○ Connects to BACnet MS/TP network; can monitor and display sensors via BACnet communications
● Optional brushed stainless steel bezel for easy cleaning
StabiliSENSE ™ Critical Room Status Monitor
Modbus®is a registered trademark of Schneider Automation, Inc.
6. Accessories
A-285
Remote Alarm Annunciator
RHP-2N44
Wall Mount Relative Humidity
and Temperature Transmitter
A-418A
Static Pressure Pickup
A-417A
Stainless Steel Wall Plate
Static Pressure Pickup
A-RSMC-BOX
Surface Mount Box for
RSMC Series
BTT-N00-3
Wall Mount Temperature
Transmitter
StabiliSENSE ™ Critical Room Status Monitor
7. Operation
● The Series RSMC can be configured to monitor positive or negative pressure in protected
environments
○ The RSMC is a complete system which enables easy access to pressure, relative humidity,
temperature, air change per hour, door status, network setup, security, calibration, and alarm setup
● The RSMC StabiliSENSE ™ critical room status monitor has graphical indication for each parameter
that will appear green when within the user-defined set range, orange when inside of the warning
set range, and red when in the alarm set range
○ The audible alarm will also sound when inside of the alarm set range
○ An alarm icon will also appear on the top of the display
● 1 analog DP pressure output and 1 digital output are also provided along with 2 analog inputs and
1 binary input
StabiliSENSE ™ Critical Room Status Monitor
8. Key Specifications
StabiliSENSE ™ Critical Room Status Monitor
● Measurement Technology: Capacitance cell pressure sensor
● Inputs: Two (2) user-selectable 4-20 mA, 0-5 VDC, or 0-10 VDC; USB type C used for cloning
programming; One (1) digital input for door status
● Outputs: One (1) digital output (DO) rated 5 A @ 30 VDC; One (1) 4-20 mA or 0-10 V (user
selectable) corresponding to internal pressure or retransmission of any input
● Display: 4.3˝ (12.7 cm) color TFT LCD, dimmable; 480 x 272 resolution
● Communications: Modbus®RTU, BACnet MS/TP
Modbus®is a registered trademark of Schneider Automation, Inc.
9. Additional Information
● You can find more information on this product by visiting our website www.dwyer-inst.com
● For any technical questions you may have, we have several Applications Engineers available by
phone or email at:
○ (219) 879-8000 x6402
○ tech@dwyermail.com
● To request a quote or place an order, contact one of our Customer Service Representatives at:
○ (219) 879-8000 x6656
○ quotes@dwyermail.com
○ orders@dwyermail.com
StabiliSENSE ™ Critical Room Status Monitor