MODEL V-209
OSCILLOSCOPE
------ .._...__ -
OPERATION MANUAL
~Hitachi Denshi.Ltd.
,;--
·--------·---------·-- -. ---.-·--._-----·---------1
If WARRANTY ,f
~ ~
1 Th1s H1tach1 Ocnsh1. Ltd. product 1s warranted against defects in workman- {
I
{ sh1p and materiah. If any failure. re~uhing from a defect in e1ther workman- ,
ship or matenal. ~hall uc..:ur un:ll!r uormal use within one year from the ~
J origmal date ot purcha~c. such failure shall be corrected free ofcharge to the f
'1 ongmal purcha~e by repair or. at Ihtachi Denshi's sole option. replacement of ~
){ the defective part or pam 'o charge shall be made for labor or services L(
pcrfonned dunng Stlld one year period providing the product is brought to I
1
( our AuthoriLcd Service St<lllun. ~l
) llitachi Ocnsh1. Ltd. further warrants to the original purchaser that upon ~~
( expiration of the one year free SCI'Ice "'arranty period and within two years r
I, from the original date of pun;has~ H11ach1 Dcnshi. Ltd. will e1ther repa1r ~~
1: llr •
.11 1ts sole uptu1n, rcpl:lcr an) part Ccept for cathode ra~ tube. fuses. ll
, probes. lamps. batterio: and otha optional materials which are defective in 1
~ euher worl..mamhip or rnatenal under n•mnal and proper use. t!
} ..Iter the expiration ut the one ~car free '>CI'ii'e period and during the addi- ll
1
' tiona) penod 'overed by two year~ pans warranty. a reasonable charge will 1
1~ be made for labor or ~en1.:e perfom1eJ. t'
ll ThiS warranty does not cover equipment which has been tampered with in ll
1
any way. or damage caused by acc1dent, negligence, alteration, or misappli· 1
r cation. ll
1
' This product mu~t be returnt:d transportation prepaid, properly packed and r
r~ insured. This warranty apphes only to the ongmal purchaser. ~~
'~ NO OTHI:.R WARRANTILS 1Rl~ EXPRI:.SSED OR IMPLII:.D. Huachi ~~
~ Denshi. Ltd. IS NOT LIABLI:: l-OR CONSEQUENTIAL DAMAGES. r
~ ~ t
l,...,,:...,:_, ,,..., ,...,_;:"'N':,,..,,;"•";,..,,-...,..,..;:-..-..:!*Iot''•"''•''"'''••lllt......,..,ltllh·',.,.,,.....,~·u~"A""- '"'"" ., ''"''" ,...,."""•""'",.oi+l+•;"~:;,...,,:•..,..,,.tt,.';~.....,;"ltiO:,.,",:"~'+II!t!o'"'";;,.,,:"''~•ltH•.....,,.,,,. •· ''"''
CONTENTS
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
3. Precautions ............................ . . ................. 2
4. Controls and connectors . ................................. . .. 6
(I) Power supply and CRT . ...
........... ..... ................ 6
(2) Controls of vertical deflection system........................ . . . I0
(3) Controls of horizontal deflection system............. ............ 12
(4) Synchronization system ................................... 13
(5) Miscellaneous........................... . . . ............. 15
5. Battery operation ......... . . ........... . ...... . ...... . .... .. 15
6. How to produce the bright line ....... . ........... .. . ............ 17
7. Method for connecting signal s .................... ....... . ...... 19
8 Measuring procedure . . . .. . . . . . . . . . . . . • . . . . . . . . . . . . . . . . . . . . . . ., .,
(I) DC voltage measurement
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • . . ., 1
(2) AC voltage measurement.... .. ..... ....................... 22
(3) Measurement of frequency and penod
........................... 23
(4) Measurement of time difference.. ............................ 23
(5 ) Measurement of rise(fall)tll1le
................................ 24
(6) Synchronization of compte ed waveform ... ...
.................. 25
(7) How to use TV exclusJve synchronization ........................ 25
9. AdJUStments . ............ ... ......... .. ......... . ...... 27
10. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
II. Specifications. . . .......................... . ........ .. ...... 2
12. External view .............................................. 32
13. Schematic diagrams............. . ............................ 33
14. Optional accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • . 42
MODEL V-209
NOTE
This instrument should be adjusted at an ambient temperature of +20°C
for best overall accuracy.
Allow at least IS minutes warmup before proceeding.
c Polyvinyl chloride (PVC) film is attached on the enclosure and the front
panel of the oscilloscope to protect the metal surface. If the PVC film is
damaged by scratches, remove it.
To clean the enclosure or the front panel, use neutral detergent. Refrain
from using thinner, bent.me. alcohol or other chemicals.
For safety operation, the instrument chassis and cabinet are sure to con­
nect the ground lead of the G D (ground) terminal to earth ground, if a
two-wire AC power system is used.
Failure to complete the ground system may allow the chassis and cabinet
of this instrument to be elevated above ground potential and pose a shock
hazard.
1. FEATURES
The Hitachi V-209 is a handy-type, advanced-class oscillo­
scope with a bandwidth of DC to 20 MHz designed with the
emphasis on operability and portability and has a following
features.
(I) Wide bandwidth:
The instrument has a bandwidth from DC to 20 MHz.
(2) High sensitivity:
Sensitivity is I mV/div
(3) 3.5-inch screen:
Employment of an internal graticule CRT permits the
waveform observation to be made without parallax error.
(4) 3-way operation:
The instrument is operated with AC-line,external DC and
Battery Pack AD-209.
(5) TV synchronization:
Employment of a new TV sync separator circuit allows the
instrument to observe TV signals stably.
(6) Auto focusing:
Focusing shift is automatically corrected.
2. ACCESSORIES
This instrument is shipped with the following standard
accessories.
2 Probes (AT-JOAK 1.5)
Fuse 1A for I OOV set or 0.5A for 200V set
Fuse 2A for DC line
AC power supply cord
DC power supply cord
Operation manual.
3. PRECAUTIONS
Precauuon� to be observed to lengthen the service life of
:hb 10 trument.
In tallation site
• ,vo1d tnstalltng mstrument in an extremely hot or cold
place.
Avoid placmg this instrument in a place exposed to sun­
light for a long period of time, in a closed car in mid­
summer, or near a room heating device such as a stove.
The operatmg maximum ambient temperature is +50°C.
• Do not use mstrument that has been left outdoors on a
cold Winter day.
The operatmg ambient temperature is 0°C or more.
• Avoid moving the instrument rapidly from a hot place to a
cold place or vice versa, or condensation may form on
ms1de of the instrument.
• Keep the instrument away from damp air, water, and dust.
L'nexpected trouble may be caused when the instrument is
placed an a damp or dusty place.
The operating ambient humidity is 35 85�.
Since an accidental antrusion of water may also cause
troubles, do not place a water-filled containers such as a
vase on the oscilloscope.
• Do not place the instrument in a place where vibration is
strong. Avoid using the instrument at a place vibrating
violently. Since the oscilloscope is a precision instrument,
excessively strong vibrations may cause damage.
• Do not place the anstrument near a magnet or magnetic
body. An oscilloscope is an equipment using electron beam
Therefore, do not bring a magnet close to the instrument or
do not use the instrument near an equ1pment generating
strong magnetic force.
Handling
• Do not put a heavy objects on the oscilloscope.
• Do not block the ventilation holes.
* Do not apply a heavy shock to the oscilloscope.
* Do not insert a wire, pin, etc. through the ventilation hole.
* Do not drag the set, leaving the probe attached to it.
* Do not leave a hot soldering iron on the cabinet or the
screen.
* Do not try to turn the instrument upside down. Otherwise,
knobs may be broken.
�b�
* Do not use the instrument upright, leaving BNC cable
connected to EXT BLANKING terminal on the rear panel.
Otherwise, the cable may be damaged.
Handle
The handle of the V- 209 can be positioned for carrying
or as a tilt-stand for the instrument. To position the
handle. press in at both pivot points and tum the handle
to the desired position. 15 positions are provided for con­
venient carrying or viewing.
3
When not in U!>e
When not m u:.e, put the dust-proof cover on the mstrumcnt
aud store 11 with care.
When Operation is faulty
Recheck the operating procedure and if problem persists.
contact a nearly service station or agent.
Care and repair
Removal of stam from the case.
When the outs1de of the case is stained. remove the stain
hy first wiping 11 lightly with a cloth moistened v.ith
neutral washmg agent and then w1pe the surface w1th a
dry cloth.
• 'ever use strongly volatile agent such as bentine and
tl mner
When the panel surface is stained, remove the stain in
sm1ilar way with a clean, soft cloth. When heavy stains
are present, first remove the stains by w1pmg the surface
lightly with a cloth moistened with diluted neutral wash­
ing agent or With alc.:ohol and then wipe thoroughly with
a dry cloth.
When dust has accumulated on the inside, remove it by
using dry brush. or by using the exhaust of a compressor
or a vacuum cleaner.
NOTE: When opening the case. pull out the power suppl]
plug beforehand without fail
When cleaning the inside, insure beforehand that no
electricity remains in the condensers of the power
supply circuit.
• Cleaning of CRT
01rty surface of CRT screen tends to cause measuring errors
The screen surface becames v1sible when the bezel is remO­
ed.
Remove the stains on CRT and filter by using a clean and
soft cloth, paying attention not to impair them.
When the stain is extremely heavy. wash them with neutral
washing agent and then leave them stand until the moisture
is removed naturally.
o If the screen is installed while it is moistened, water
rings may be formed and the wavefom1 may be blurred
to make observation hard. Pay attention not to leave
finger prints on it.
To dismount it, pull it toward
you pressing it at the both
ends.
Operation precautions
Bcz:el
* Check the line voltage is in the range specified in the table
below.
Rating Allowable line voltage (50/60Hz)
ACIOOV AC90V 130V
AC200V ACI80V 260V
Usually the voltage selector switch on the rear of the V-209
has been set to IOOV AC at the factory. When this is operat­
ed on 200AC voltage, set the selector switch to 200 V AC.
(Rated voltages are marked above the power connector on
the rear panel.)
* Use only specified fuses
In order to protect the circuit against over-current, a 0.5A
(in primary side of power circuit) and 2A (in secondary
side of power circuit) are used. When the fuses blow out,
check thoroughly the cause. repair any faulty point present.
and then replace them with specified fuses. Do not try to
use the fuse other than the specified ones. Otherwise, fault
may be caused or danger may be invited. (Particularly. do
not use a fuse different from the specified one in current
capacity and in length.) The standards of the fuses are as
follows.
Shape
JIS type name
{Diameter x length) mm
2A 6.35cf> X 31.8 MF6JNM250V 2A AC
lA 6.35¢ X 31.8 MF61 M250V lA AC
0.5A 6.35¢ X 31.8 MF61 M250V 0.5A AC
* -(negative) terminal of EXT DC I is inside connected to
case ground. Do not connect - (negative) terminal of the
V-209 to the + (positive) grounded case of other instru­
ments with common external DC power source to the
V-209. If not, it is very dangerous because a large current
nows through the grounded line.
5
6
V-209
Grounded line
Other in�trument
Common external
DC power source
< DANGEROUS CONNECT>
* Do not apply rever e polarities to EXT DC IN.
• Do not mcreasc the bnghtness too much. Your eyes rna) be
steamed and the nuorescent surface of CRT may be burnt.
• Do not apply an excel;sive voltage.
The maximum volt3ge of each input is as follows.
PUT direct 250V (DC+ peak AC 3t I kilt.)
When xI0 Probe is used 250V (DC+peak AC at I kilt.)
E T TRIG INPUT 250V (DC+peak AC)
EXT BLA Kl G SOV (DC +peak AC)
4. CONTROLS AND CONNECTORS
(I) Power supply and CRT
Operating voltage and fuse
Thts model can be operated from e11her 3 100 volts or a
:!00 volts nominal line vohage source. The line voltage
select switch on the rear panel, turn the instrument from
one operating range to the other. In addition, this switch
changes the primary connections of the transformer to
allow selection of one of two regulating ranges. Use the
following procedure to convert this instrument between
normal line voltage or regulating ranges
a. Disconnect the instrument from the power source.
b. To convert from I 00 volts nominal to :!00 volts nomi­
nal line voltage or vice versa, remove the protector of
the line voltage select switch.
Change the line voltage select switch from I 00 volts to
200 volts and remounting the protector.
c. Before apply the power to the mstrument, check that
the indicating tabs on the rear panel.
Selection of power supply mode
This oscilloscope can make operation by using three kinds of
AC power supply, external DC power supply and A[}209bat­
tery pack.
T
The S itches are set as shown in the table below to establi�h
each power �upply mode
Switche
Po.1.-er source Power mode
upplylnode select witch (J) select witch @
----
t
AC IXOP
DC D OP
DC
t- 0 OP
When charging DC BATT CI-IARGC
(AD-209)
*DC II to 14V IS supphed via EXT DC I PUT connector.
<WARNING>
After completing the charge of AD-209, be sure to set
power mode select sw1tch to DC OPE.
When the output voltage of DC power supply becomes less
than IIV. the power lamp 1 blmking. When the output
'Oitage 1s less than approx I0.5V. it stops the operauon to
prevent the battery ovenltscharge.
When mstrument is operated by u�ing the AD-209, refer to
chapter 5, "Battery Operation."
n When the AD-209 IS not used, it is possible that the
CIIARGE lamp is illummated by setting the Charge mode.
Lxternal DC operation
The V-209 can be operated by e'temaliX l>Ource (II to 14
volts)
In tillS case, DC source IS supphcd by the attached external DC
ource cable. Connect the whtte hne of source cable to plus(+)
s1de Reversing polanty connecuon may cause blow of the
fuse
D-209 and external DC source are automatically switched
by mserting the external DC source cable into EXT DC
INPUT connector.
7
Front View
8
8 rJ)
Rear View
9
CD POWER switch
After checking the line voltage select switch, set POWER
switch set to OFF and then connect the AC cord to AC
wall socket.
(}) POWER lamp
This lamp goes on in red when the power supply is in
ON state.
G) CHARGE lamp
This lamp goes on in red in the battery charge mode.
When the battery is completely charged, this becomes
dim.
@) FOCUS control
After obtaining an appropriate brightness by operating
INTENsity,adjust FOCUS until the bright line becames
clearest. Although the focus is also corrected automati­
cally when INTEN is rotated, the focus is sometimes
slightly shifted.
@ TRACE ROTATION control
Used to align the trace of CRT with the horizontal
graticule.
@ INTENsity control
JO
Works as the brightness adjustment. Brightness is increas­
ed by rotating INTENSsity clockwise.
(j) Power source select switch
Used to select the power sources.
AC Operated with the AC power source
DC Operated with the AD-209 or external DC
power source
® Power mode select switch
Used to select the power mode.
See Selection of Power supply mode.
<CAUTION>
Do not set the Power mode select switch to the BATT
CHARGE except charging batteries.
® EXT DC INPUT connector
See External DC operation.
(2) Controls of vertical deflection system
@ CH 1 INPUT connector
B C connector for vertical axis input
The signal input to this terminal becomes the X-axis sig­
nal when the instrument is used as an X- Y oscilloscope.
@ CH2 INPUT connector
Thr same as CHI, but when the instrument is used as an
X- Y oscilloscope, the signal input to this terminal
becomes the Y-axis signal.
@@ Input coupling switches (AC-GND-DC)
Used to select the coupling system between the input
signal and vertical axis amplifier.
AC At this setting. the signal is connected through a
condenser. The DC component of the input
signal is cut off and only the AC component is dis·
played.
GND At this setting, the input to the vertical axis ampli­
fier is grounded.
DC At this setting, the input signal is directly con­
nected to the vertical axis amplifier and displayed
unchanged, including the DC component.
� @ VOLTS/DIV select switches
A step attenuator which selects vertical deflection fac­
tor. Set it to an easily observable range corresponding to
the amplitude of the input signal.
Multiply the reading by I 0 when the I 0: I probe is used
in combination with the instrument.
@@ VARIABLE controls
Fine tuning device is used to vary the vertical deflection
sensitivity continuously. Attenuation of less than 1/2.5
is obtained when this device is rotated in the reverse
direction of the arrow to the full.
This control is used when comparing wavefom1s or when
measuring the rise tinle of a square wave in 2-channel
observation. Normally this control is left rotated in the
direction of the arrow to the full.
@@ POSITION controls
Used to adjust the position of the vertical axis.
The image rises with the clockwise rotation of this knob
and falls with the counterclockwise rotation. When the
knob is at PULL position, (pulled up state) the gain of
the vertical axis is magnified 5 times and the maximum
sensitivity becomes I mY/DIY.
@ MODE select switch
Used to select the operation mode of the vertical deflec­
tion system.
CH J Only the signal that has been applied to CHI
appears on the screen.
CH2 Only the signal that has been applied to CH2 ap­
pears on the screen.
J 1
ALT Signals applied respectively to CHI and CH2
appear on the screen alternatively at each sweep.
This setting is used when the sweep time is short in
2-channel observation.
CHOP At this setting, the input signals applied respec­
tively to CHI and CH2 are switched at about
250 kHz independent of the sweep and at the
same time appear on the screen. This setting is
used when the sweep time is long in 2-channel
observation.
ADD The algebraic sum of the input signals applied
respectively to CHI and CH2 appears on the
screen..
@ CH2 INV button
12
Used to inverse the polarity of the input signal applied
to CH2. Inversion occurs in a state where the knob
of the pushbutton is depressed ( _o._ ) and restored to
normal when the knob is in protruded state ( _0_ ).
This switch is conveniently used in the comparison of
two waveforms having different polarity or in the
observation of the waveform of the difference signal
!CHI l - !CH2 I between CHI and CH2 using ADD.
(3) Controls of horizontal deflection system
@ TIME/DIY �lect switch
Sweep time ranges are 18 steps from 0.5 psjdiv to 0.2s/
div.
X-Y This position is used when using the instrument as
an X-Y oscillsocope.
In this position, the X (horizontal) signal is con­
nected to the input of CH1; · the Y (vertical)
signal is applied to the input of CH2 and has a
deflection range from less than one millivolt to
5 volts/div at a reduced band-width of200 kHz.
@ SWP VARiable control
Works as CAL and the sweep time is calibrated to the
value indicated by TIME/DIY.
TIME/DIV of sweep can be varied continuously when
shaft is out of CAL position.
Then the control is rotated in the direction of arrow to
the full, the CAL state is produced and the sweep time
is calibrated to the value indicated by TIME/DIY.
Counterclockwise rotation to the full delays the sweep
by 2.5 times or more.
@ FINE PULL xlO MAG :::POSITION control
Used to move the bright line in horizontal directions.
It is indispensable to the measurement of the time of
waveform.
Bright line is moved toward right when the knob IS ro­
tated clockwise and toward left with counterclockwise
rotation. The outer shaft is for coarse adjustment and
the inner shaft for fine adjustment.
@ x 10 MAG control
A and B sweeps are magnified I0 umes by pulling
out FINE knob (inner shaft) of POSITION. In
this case, the sweep time is I/10 of the value indicated
by TIMEtDJV. Bring the position of the waveform
to be magnified for observation from the center of
the scale by operating =::POSITION of the horizontal
axis. Next.switchxiOMAG switch to PULL (pulled
out state). Then the waveform placed at the center ts
magnified in right and left directions. The sweep time
in this case is I 0 times of the sweep speed obtained by
TIME/DIV, in other words. the reading is I 10 of the
sweep time indicated.
I ! I
.
f-
y
;ft
f-1-
i-Ii
r-1 �
I

I !
--'-
I ! !
lf- f--+- t -
���
._ t ; 1
I I I
Magnified �--avefom1
(4) Synchronization system
@ SOURCE select switch
U ed to select the triggering signal source A sweep.
Cll l The input signal applied to CHI becomes the trig­
gering signal
CH� The input signal ttpplied to CH2 becomes the trig·
gering signal.
13
LINE This setting is used when observing a signal trig­
gering with power supply line frequency.
EXT External triggering signal applied to TRIG IN­
PUT becomes the triggering signal.
This setting is used when triggering with a special
independency of the vertical axis signal.
@ TRIG INput connector
Input terminal used for external triggering signal of
A sweep.
@ TRIG LEVEL control
14
Used to decide at which portion of the waveform
the sweep should be started by setting trigger level.
This control is also enabled to switch SLOPE.
Depressed position (nonnal state) is for <±>SLOPE and
PULL position (state in which the knob is protruding) is
for 8 SLOPE.
Explanation of synchronization polarity SLOPE
Push
at time of
@SLOPE
Pull
at time of
8 SLOPE
Explanation of synchronization level LEVEL
0
f'
,_
At the time
_ of(±) SLOPE
,-,
+
 At the time
o - ofG SLOPE
-
-/
@ TRIG MODE select switch
AUTO Brought into automatically triggering sweep
in which sweep is always conducted.
In the presence of triggered signal, normal
triggered sweep is obtained and the waveform
stands still. In the case of no signal or out of
triggering, sweep line will appear automatically.
This setting is convenient in usual cases.
NORM Triggered sweep is obtained and sweep is con­
ducted only when triggering is effected. No
sweep line will appear in the case of no signal or
out of synchronization. Use this MODE when
effecting synchronization to a very low fre-
quency signal (30Hz or less).
TV(V) This setting is used when observing the enure
vertical picture of television signal.
TV(H) Th1s setting is used when observing the entire
horizontal picture of television signal.
(NOTE) Both TV V and TV H synchronize only when
the synchronizmg signal is negative.
(5) Miscellaneous
@ EXT BLANK connector
Input terminal for brightness modulation. It is of the DC
coupling. The brightness is reduced with a positive signal
and increases with a negative signal.
@ CAL O.SV tip
Output terminal of calibration square wave of about
I kHz and O.SV. It has a tip terminal. It is used to cali­
brate the probe combination.
@ GND terminal
Earth terminal of the oscilloscope.
5. BATTERY OPERATION
Operation of battery pack AD- 209
I) Set the Power source select switch (j) to DC and the
Power mode select switch@to DC OP.
2) Tum on the POWER switch CD. Then the V-:!09 starts
to operate on the power from the AD-:!09.
The continuous operation time is one hour and half. If
the battery is operated 1n excess of this period, the ter­
minal voltage will decrease sharply and the battery will
be in the over-discharged condition.
In this model, an alarm circuit will be activated before
the over-discharging and the POWER lamp G) starts to
Oash. In this case, charge the battery immediately.
Note: When the alarm c1rcuit IS energized and the volt­
age is lowered down to IO.SV, the power of the
V-209 is off automatically to prevent the over­
discharge of the AD-209.
The selection of the AD- 209 and an external DC
source is made by the external DC input con­
nector ®.
15
Charging of battery
I) (onne..:t the C cord 10 an AC outlet and set the
,(-DC swnch (J) to DC and the DC 01' BfT
CIIARGL switch @ to BAIT CHARGE.
:::! ) Turn on the pl)>Ner swit..:h CD and the charging will stan.
In this case. the POWER lamp is not illuminated.
3) The ( 111RG! lamp Q) is bemg J!luminated dunng the
�harge. II will take about IS hours until the battery is
charged completely. When the charging is completed, the
CHARGf lamp becomes dim.
4) When the V-109 is operated on the AC source. while it
is connected with the AD- :::!09. the AD-209 is in the
trickle charge mode.
Operating con iderations
16
Do not short the both polarities.
Do not throw the battery pack into fire.
a) Charge the battery m the ambient temperature from
10 to 3S
0
C'.
Do not charge the battery for three days or 4g
hour in succession. This will shorten the life of
the battery.
b) Store the battery pack in a cool and dark place and
in the ambient temperature from -IS to 35°C.
When a battery stored for an e'tended period is
used. chargr it for IS hours.
1.') The hfe or the battery pack IS subject to the am­
bient temperature. load cond1t1on and continuous
operation.
Usually. the number of the charge and discharge is
over 300.
If a charge and discharge is made once a day. the
life will be more than one year. If the life is over,
the battery can not operate nom1ally. In this case.
replace the battery.
d) Charge the spare battery once a month to prevent a
self-discharge of the battery.
AD-209 battery pack replacement procedure
1) Disconnect the power cord.
2)
a) Remove four screws on the upper enclosure, then
remove the upper enclosure (Refer to the Fig. a).
Remove the screws and the plate shown in the Fig.b.
b) Disconnect the connecwrs between the battery
pack and the oscilloscope and take out the battery
pack AD-209.
c) Install the new battery pack AD-209 to the com­
partment as shown.
------------------------------------------------
Then connect the battery pack connector to the
connector of the oscilloscope.
d) Mount the plate with screws.
e) Fix the upper enclosure on the oscilloscope with
four screws.
Fig. a
Fig. b
<CAUTION>
Upper enclosure
,
Bauery
Baucry pack Battery pack fi,ing �crew
AD-209
When mounting the battery pack AD-209, take care not
to damage the connecting cables and components.
6. HOW TO PRODUCE THE BRIGHT LINE
Before turning 0 the POWER switch. insure the power
supply voltage is within the range of 90-J30V for AC IOOV
set. 180 260V for AC 200V set.
Insert the plug of the power cord on the rear panel into the
power supply wall socket and set the controls as follows.
POWER OFF
INTEN Counterclockwise to the full
FOCUS M1drange
AC-GND-DC GND
�I POSITION Midrange {the knob is left
depressed )
V. MODE (Ill
TRIG AUTO
TRIG SOURCE CHI
TIME/DIY 0.5 ms/div
::: POSITION
I
Midrange
Set all the levers of the switches to the upper side.
After ending all the setting mentioned above. turn 0 the
POWER and. 15 second later, rotate the INTEN knob clock­
wise. Then the sweep bright line will appear. If the observation
is to be started immediately. set the FOCUS control at a point
where the bright line is sharpest.
17
If the instrument is not used with the power supply turned
on. rotate the I TENsity counterclockwise to reduce the
brightness and also blur the FOCUS.
NOTE
For usual observation, leave the following non-calibrating
function section set to ''CAL" position.
VARIABLE Rotate in the direction of arrow.
In this case, the VOLTS/DIV is calibrated to
its indicating value.
SWP VAR Leave the knob in depressed state.
In this case, the TIME/DIV is calibrated to
its indicating value.
Align the bright line with the horizontal scale line at the
center of the screen by operating CHJ POSITION. In some
cases,the bright line may be oblique to the scale slightly by the
effect of earth magnetism. In this case. bring the bright line
until it lies on the horizontal scale line at the center of the
screen by properly adjusting the semi- Gxed variable resistor
TRACE ROTATION on the front panel.
18
GENERAL MEASUREMENT
(I) I n the case of observing a single waveform.
Use CHI or CH2 when not observing the phase difference
between two waveforms or when engaging in a operation
other than X- Y operation. Make the following settings
when using CHI .
MODE Switch of Vertical defection system CHI
MODE Switch of TRIG AUTO
TRIG SOURCE CHI
Under these settings, almost all the repetitive signals of
about 30 Hz or more applied to CHI can be synchro­
nized and observed by adjusting TRIG LEVEL. Since
the MODE of horizontal axis is at AUTO position, the
bright line appears even when no signal is present or when
input coupling switch is at GND position. This means
that the measurement of DC voltage can be measured. The
following switching is needed when observing low fre­
quency signals of about 30 Hz or less.
MODE of TRIG ORM
Synchronization can be effected by operating LEVER knob
under this setting.
When using only CH2, use the instrument after making the
following settings.
MODE Switch of Vertical Axis
TRIG OURCE
(2) When observing two wavefonns
CH2
CH2
Observation of two wavefom1S can be made easily by
setting the MODE switch of vertical axis to ALT or CHOP.
When observing two wavefonns of high repetition frequen­
cies, set the MODE switch to ALT and, in the case of low
frequencies, set it to CHOP.
Measurement of the phase difference is performed after
effecting synchronization with leading phase signal.
(3) When observing wavefonn with X- Y
Set the MODE switch of vertical defection system to CH2
(X- Y) and TIME/DIV switch to X- Y. Then the instrument
works as an X-Y oscilloscope.
Each input is applied to the instrument as follows.
X-axis signal (horizontal axis signal)
Y-axis signal (vertical axi� signal)
CHI INPUT
CH2 INPUT
In this case.leave the horizontal axis magnification switch
(PULL-MAG x 10 inner shaft knob) at depressed position.
7. METHOD FOR CONNECTING SIGNALS
The first step of measurement is to introduce the signal
desired to measure to the oscilloscope properly. Do it with
utmost care.
(I) When using a probe
Use the attached probe, AT-I 0 AK I .5, when measuring a
high frequency wave with high accuracy.
It should be noted, however, that since the input signal is
attenuated by this probe to 1/10 before it is input to the
oscilloscope, the use of the probe is disadvantageous for
low signals, and that at the same time, the measuring range
is extended by that amount for high signals.
<CAUTIONS>
o Do not apply a signal which exceeds 250V (DC+ peak
AC at I kHz).
o Bring the grounding point of the earth lead wire of the
probe close to the point to be measured when measur­
ing a rapid rising signal or a high frequency signal. Long
earth lead wire may cause wavefonn distortions such as
ringing and overshoot.
19
Connection of earth lead wire
20
(a) A good example (b) A bad example
For better measurement. it is required to use an earth
attachment available at option.
Multiply the reading of VOLTS DIY by 10.
For example. if the VOLTS/DIY ts SOmV/DIV. then
read the wavefonn as
SOmV/DIV x 10 = SOOmV/DIV
o To avoid measurement error, put the probe in the follow­
ing correction state and check it before measurement
without fail.
Connect the tip of the probe to the output tenninal
CAL O.SV of I kHz calibration square wave voltage.
When this correction capacity value is at optimum,the
wavefonn takes the shape as shown in Fig. (a) as follows.
If the wavefonn is as shown in Fig. (b) or Fig. (c),
rotate the semiftxed adjusting screw on the matching
box of the probe by using a screwdriver until the opti­
mum state is obtained.
L Capacitance correction trimmer
JliUlJ1 MJUl MM
(a) Optimum (b) Capacity too
small
(2) At time ofdirect connection
(c) Capacity too
large
When connecting a signal directly to the oscilloscope not
usmg the attached probe AT-10 AK 1.5 (IO· 1 ), pay atten­
tion to the following points in order to minimize the mea­
surement error.
o When perfonning observation using a bare lead wire, no
trouble occurs on the circuit to be measured at low
impedance and high level.
However. note that, in most cases. measurement error
may be caused by static stray coupling with other circuit
and power line.
This measurement error cannot be ignored even in low
frequency region.
In general. tt tS safe to avoid measunng with non­
shielded connecting wire. When using a shieldmg wire,
connect one end of the shield to the earth terminal of
the oscilloscope and the other end to the grounding of
the circuit to be measured. It is deirable to use a coaxtal
cable with B C type connector.
The following cautions must be observed when per­
forming a wide band measurement. It ts necessary to
terminate with the characteristic impedance of the cable
when measuring a rapid nsing waveform or a high fre­
quency wave.
Especially when using a long cable. the absence of a
terminating resistor will necessarily lead to a measure­
ment error derived from ringing phenomenon. Some
measunng circutls require a termmating reststor equal to
the charactensttc unpedance of the cable also on the
measurement terminal stde.
B C type terminating reststor (50 Q) ts conveniently
used for this purpose.
c In order to perform measurement with the measuring
circuit put in proper operating state, it is sometimes
necessary to terminate the cable with an impedance
which corresponds to the circuit to be measured.
o The stray capacity of the shield wire must be taken in10
account when performing measurement with a long
shield wire. Since the shield wire normally in use has
a capacity of about I 00 pF per meter. its effect on the
circutt to be measured cannot be ignored. Use a probe to
minimize the cffection the circuit.
When the length of the shield wire is used or when the
length of the non-terminated cable reaches I 4 wave
length or its multiples within the band of V-:!09 type
(I 4 wave length is about 3 meter when using a coaxial
cable at }0 MHz), oscillation may be caused near 5 mV
DIY range.
This is caused by the resonance between the externally
connected high-0 inductance and the input capacity
and can be avoided by reducing the Q.
Connect the cable or shield wire to the input connector
by way of a senally connected I OOU to I n reststor, or
perform measurement at other VOLT/DIY range.
21
8. MEASURING PROCEDURE
The first things to do are as follows.
o Bring the brightness and FOCUS at optimum positions
for easy read out.
� Display the waveform as large as possible to minimiLe
the read error.
Check the capacity correction when using a probe.
(Refer to paragraph (I) "When using a probe" of Sec­
tion 7. "Method for connecting signals" for correcting
capacity.)
(I) DC voltage measurement
Set input coupling to G D and decide the zero level prop­
erly.
Set VOLTS/DIV appropriately and set AC-G D-DC to
DC. Since the bright line shifts here by the amount of
DC voltage, the DC voltage of the signal can be obtained
by multiplying the shift width by the indicated value of
VOLTS/DIV. When VOLTS/DIY is 50 mV/DIV, then
SO mV/DIV x 4.2 = 210mV (However, if the probe AT-
10 AK I .S (10:1) is in use, the true value of the signal be­
comes 10 times of the value, or SO mV/DIV x 4.2 x 10
= 2.1V.)
DC voltage (after shifting)
Zero level (reference line)
(2} AC voltage measurement
The same as paragraph 8 (1). "DC voltage measurement",
but here there is no need of align the zero level with the
scale line. Set the zero level to the position that can be
easily observed.
In the drawing as follows, VOLTS/DIV is IV/DIY, IV/
DIY x S = S Vp-p (SOVp-p at time using the probe AT-
10 AK 1.5(10: 1)). When magnifying and observing a small­
amplitude signal, superimposing on a high DV voltage,
set the input coupling to AC. The DC voltage is cut off and
AC voltage can be observed by increasing sensitivity.
r
/f - - - - �ff--
1 I 1
17 1
H--+--f--t-1-t-+---+-_+=1_-- ---
(3) Measurement of frequency and period
This will be explained with the following figure.
One period covers the time A and time B, which are sepa­
rated from each other by 2.0 DIY on the screen.
When the sweep time is Ims/DIY, the period is given by
1 ms/DIV x 2.0 = 2.0 ms
=2.0 X 10-3 S
Accordingly, the frequency is
1/(2.0 X J0-
3
)= 500Hz
(However, when the knob MAG x!O is at pulled out posi­
tion, TIME/DIY must be converted to I /10 since the sweep
is magnified.)
I- +-
-1
- -I-
� . * •
-
-------
-
71
f/ l
I-
T II
711/
I
rr .,
u
-- - -
Time A Time B
II
---
1
-
-lh__:
v�
I-
(4) Measurement of time difference
Triggering signal source ''SOURCE" is selected as an offer­
ing reference signal when measuring the time difference be­
tween two signals. Assume that pulse trains as shown in (a).
Then (b) shows the case when CHI is taken as the triggering
signal source and (c) the case where CH2 is taken.
I I
CH I �
CH2 �­
�- (a)
(b)
I
I
-_I
,-+-
.:::.
CH
:..:...:..
I __
_
I
CH2
(c)
23
24
This means that CHI is used as the triggering signal when
investigating the length of time by which the signal of CH2
is delayed from the signal of CH 1. CH2 is used in the
reversed case. In other words, the signal leading in phase is
selected as the triggering signal source.
If this process is reversed, the portion to be measured may
sometimes not appear on the screen. Thereafter, equalize
the amplitudes of the two signals appearing on the screen or
superimpose one on another.
Read the time difference between 50% amplitude points
of the two signals.
Sometimes the superimposing method is more convenient
from the point of view of procedure.
� it
'
---
-
�
Time
=> difference Equalize
"' �
�amplitudes
-----J_-:;- by VAR
(a) Equal amplitude
measuring method
<CAUTIONS>
(b) Suerposition
measuring method
Since the pulsed wave contains many high-frequency wave
components (higher harmonics) depending on its width or
period, pay the same attention as given to high frequency
signals when handling it. Accordingly, use a probe or coax­
ial cable and shorten the earth lead wire as much as possible.
(5) Measurement of rise (fall) time
To measure the rise time, pay attention not only to the
abovementioned items but also to measurement error.
The following equation is provided for the relation among
the rise time Trx of the wavefom1 to be measured, the rise
time Trs of oscilloscope, and the rise time Tro displayed on
the screen.
Tro =../Trx2 + Trs2
When the rise time of the pulse going to be measured is
sufficiently longer than the rise time of the oscilloscope
(17.Sns in our case),the effect of the rise time of the oscil­
loscope on the measurement can be neglected. However, if
both are close to each other, measurement error may be
caused.
The true rise time is given by
Trx = .../Tro2 - Trs2
Moreover, in general, in a circuit free from waveform dis­
tortion such as overshoot and sag, the following relation­
ship is established between frequency band and rise time.
fc x tr = 0.35
Where, fc: Frequency band (Hz)
tr: Rise time (s)
The rise time and fall time are determined by the time
elapsed between the I 0'1 to 9Qc,r 'alues of pulse width.
(6) Synchronization of complexed waveform
In the case shown in the Fig. (a) below where two wave­
forms have difference in amplitude alternate. the wave­
form is doubled if the trigger level is not set properly. In
the case where the trigger level is selected as Y line two
waveforms. one starting with A and advancing to B. C. D, E.
F.... and the other starting �ith E and advancing to F,
G. H, I .... will appear alternately on the screen. They
will be doubled as shown in Fig. (b), for which no synchro­
nization can be taken.
In such a case, rotate LEVEL clockwise until the trigger
level comes to Y' line. Then the waveform on the screen be­
comes the one shown in F1g. (c) above wh1ch starts with
B and advances to C, E. r, . . . and which allows synchro­
niLation.
/TC. .7 h/"'-� 0
�
� � v J.......,. L� p=
(a) Signal waveform
Y' Trigger level
y �Lting line
(b) When the uiggcr (c) When the uigger
...:ning level •� Y selling level i' y·
Synchronization of complexed waveform
(7) How to use TV exclusive synchronization
CD On the image waveform of TV
In the work concerned w1th TV. comple:-.ed signals con­
taining video signal. blanking pedestal signal. and syn­
chronizing s1gnal are often measured. llowever, since
the waveform is complexed, a special circuit IS needed
10 effect a stable syncrhonization with vertical waveform.
Synchronizing
signal pulse
(SYNC pulse)
IV (vertical) ------�
25
26
Q) Difference in the circuits
Exclusive circuit for conventional oscillograph
General circuit
Video �ignal
To trigger circuit
Hard to synchronize, because
video signal is applied directly
as trigger signal.
Simple synchronizing
circuit
To trigger circuit
Synchronization is more easily
effected than in the circuit
shown at left, because the
signal is integrated to remove
high frequency components.
Exclusive circuit for this
instrument
(Principle drawing)
TV exclusive synchronizing
separator circuit
To trigger
cucuit
After picking up the SY C pulse,
the vertical synchronization is
separated. Then, the stable syn­
chronization is obtained.
Q) Operation
[!RIG) MODI l V-V ,TRJCJ MODI: fV-11
( Oll ) lim Otlllmcopc ,ynchronizc� llh only
(-) ,ym;hronum)! l!!nal.
(REFERENCE)
Video
tgnal
Synchronizmg
signal
(a) Example of(-)
synchronizing signal
(b) Example of(+}
synchronizing signal
9. ADJUSTMENTS
The ATT balance of the '-Crtkal "''scan be made easily.
Qj ct the input couphng �Htchc of CIll .tiiJ CH� to
G:-.:D and set the TRIG MODI to Lro. 1hen posn10n
the bright line to the center.
� Turn the VOLTS DIY switch to SmV IOmV and ad­
JUSt it so that the bnght line does not move (Remove the
cover).
CHI
DC B-L
-dJU'tm.:nt o
l..:::..
--l-�./
,...
10. MAINTENANCE
28
I) Since semiconductors, precJsJon components, etc. are
employed in this oscilloscope, use atmost care for opera­
tion and storage.
2) Clean the scale with soft tissue periodically.
3) Store this oscilloscope in the ambient temperature from
-15 to +60°C (except for the battery pack AD-209) .
11. SPECIFICATIONS
!CRT!
Type
3.5-inch rectangular CRT with internal graticule.
Phosphor
P31 standard
Graticule
8 x 10 div (div = 6.85 mm)
Internal graticule
Focussing
Possible (with automatic focus correction circuit)
Trace rotation
Brightness adjustment
Present
Possible
IZ-AXIS INPUT (INTENSITY MODULATIO@
DC-coupled, positive-going signal decreases intensity:
SVp-p signal causes noticeable modulation at normal
intensity: DC to l MHz
Input impedance Approximately 50 k ohm
Maximum input voltage SOV (DC + peak AC)
Coupling DC
VERTICAL DEFLECTION SYSTEM (2 identic��hannet
S}]
Bandwidth and rise time
DC to at least 20 MHz and rise time 17.5 ns or less. DC
to at least 5 MHz and rise time 70ns or less at magnifier
extends. The AC coupled lower -3dB point is I0 Hz or
less.
Deflection factor
SmV/div to SV/div in 10 calibrated steps in a I 2 5
sequence. Uncalibrated continuous control extends de­
flection factor to at least 12.5 Volts per division in the
5 Volts/div position. xS MAG increases sensitivity of
each deflection factor setting to I mV/div.
Accuracy
±3% (+10 to +35°C)
Additional error for magnifier ±2%
Display modes
CHI, CH2 (normal or invert), Alternate, Chopped
(approximate 250kHz), Added
Input impedance
1 MS1 ±1.5c;( in parallel with 30 ±3pF
Maximum input voltage
250V (DC+ peak AC') or SOOVp-p A(' at IkHz or less
Input coupling
AC,GND. DC
LHORIZONTAL DEFLECTION SYSTEM]
Time base
O.Sps/div to 0.2s/div in 18 calibrated steps in a I 2 5
sequence. Uncalibrated continuous control extends de­
flection factor to at least 0.5 seconds per division in
the 0.2 sec/div position. xI0 MAG extends maximum
sweep rate to 50ns/div.
Accuracy
±3% (+IOto +35°C)
AdditionaJ error for magnifier ±2%
[TRIGGERING SYSTEM!
Trigger modes
Automatic, Normal, TV (TV-H orTV-V)
29
JO
Trigger source
Internal (ChI. Ch2), Lmc, l:.:<temal
Trigger slope
+,-
TV sync polarity
TV(-)
Triggering level variable range
Internal: ±4 div or more
External, approximately±IV
Triggering sensitivity and frequency
TV-V sen ithit)< SY'( scctton less than 0.7 dtv or 200mV
AUTO lo"' band Approtm:uely JOH1
A trigger coupling
Af · 20 II; to full bandwidth
External trigger input impedance
I �·.H'2 ±20• m parallel with 30 ±6pF
Maximum input voltage
250V (DC+ 1C peali.)
fX- Y OPERATION (CHI; Horiz. CH2. Vert�
Deflection factor
Same as vertical tlencction
Accuracy
Y ±3% (+10 to+3'0C)
X: ±Srr,. (+10 to +3�0C)
Additional error for magnifier ±2"'
X-bandwidth
DC to at least 5001i.llt
Phase error
3°f or Jess from Df to I OOJ...II1
CALIBRATOR
An approxtmatc I kilt frequency O.SV (+I 0 square
wave
IPOWER SUPPLY I
VOLTAGE {S0/60Hz)
I OOV (90 130V)
200V (180-260V)
Power supply frequency: SO, 60,400Hz
Power consumption: Approx. 18W
FUSE
lA
O.SA
EXT DC power supply: DC IIV-14Y Approx. 0.8A
'
ENVIRONMENTI
Limit of operation temperature
Limit of operation humidity
Rated range of use temperature
Rated range of use humidity
Storage and transport temperature
fDIMENSIONS AND WEIGHTI
Approx. 215(W) x IIO(H) x 330(0) mm
(8.6(W) x 4.4(H) x 6.4(0) inch)
35 85%
45-85%
-20-+70
°
C
Approx. 4.5 kg (10 lbs)
joptionI
Accessory pouch
Hood
Shoulder belt
IAD- 209 type Battery�
Batteries
Nominal capacity
Nominal voltage
I0 rechargeable
A nickel-cadmium cells
1800 mAh
12V
Battery execessive discharge protection
Instrument operation automatically interruped when
battery charge drops to approximately J O.SY.
Charge current Approx. 180 rnA
Charge time 13-16 hours for full charge
31
1 2. EXTERNAL VIEW
32
TOP YiC�
......
..
•
•
00
000000
0
0
··�
SIDE view
UniL: mm
'10DEL V- 209
14. OPTIONAL ACCESSORIES
Shoulder belt
1. Check the following parts packed along with the should­
er belt (No. 8101) in the Polybag.
a) Binding screw M3 x 6
(Code XCA6306) . ...
.......... Four pieces
b) Triangle clasp
(0#8301104) . . . ... ........ Two pieces
c) Clasp (D#x8301102) Two pieces
d) Belt (D#x876416) ................One piece
2. Mounting
42
To carry the model V-209 oscilloscope with the should­
er belt hanged up, execute the hooking of the shoulder
belt (No. 8101) as follows.
I ) Mount the triangle band clasps on the positions
shown in the figure, using the screws a).
2) Then, hang the clasp mounted across the shoulder
belt (No. 8101) into the triangle clasps mounted as
1).
Accessory pouch
Mount the accessory pouch to the model V-209 oscilloscope.
I) Insert the edge Q) of the accessory pouch into the
body (!)•.
2) Bend the accessory pouch and insert the section Q)into
G)·.
hitachi_v-209_oscilloscope intruction manual.pdf

More Related Content

Similar to hitachi_v-209_oscilloscope intruction manual.pdf

Sony PMW-320K Operation Manual
Sony PMW-320K Operation ManualSony PMW-320K Operation Manual
Sony PMW-320K Operation Manual
AV ProfShop
 

Similar to hitachi_v-209_oscilloscope intruction manual.pdf (20)

8107 wib usermanual
8107 wib usermanual8107 wib usermanual
8107 wib usermanual
 
Dukane 8107 wib usermanual
Dukane 8107 wib usermanualDukane 8107 wib usermanual
Dukane 8107 wib usermanual
 
Dukane 8107 wib usermanual
Dukane 8107 wib usermanualDukane 8107 wib usermanual
Dukane 8107 wib usermanual
 
t v color Panasonic Tc 20 29-g12p
t v color Panasonic Tc 20 29-g12pt v color Panasonic Tc 20 29-g12p
t v color Panasonic Tc 20 29-g12p
 
Sony PMW-320K Operation Manual
Sony PMW-320K Operation ManualSony PMW-320K Operation Manual
Sony PMW-320K Operation Manual
 
Avtron Pinhole Lens Camera Aa 4522 p-fs-manual
Avtron Pinhole Lens Camera Aa 4522 p-fs-manualAvtron Pinhole Lens Camera Aa 4522 p-fs-manual
Avtron Pinhole Lens Camera Aa 4522 p-fs-manual
 
Dmcfz28
Dmcfz28Dmcfz28
Dmcfz28
 
Panasonic dmc-fz28
Panasonic   dmc-fz28Panasonic   dmc-fz28
Panasonic dmc-fz28
 
Datavideo PD-1 Power Distribution System
Datavideo PD-1 Power Distribution SystemDatavideo PD-1 Power Distribution System
Datavideo PD-1 Power Distribution System
 
Tcl nx56c la-chassis_14f1_tda11145ps-n3-3_tyea1533p_stv9302b_tv_sm
Tcl nx56c la-chassis_14f1_tda11145ps-n3-3_tyea1533p_stv9302b_tv_smTcl nx56c la-chassis_14f1_tda11145ps-n3-3_tyea1533p_stv9302b_tv_sm
Tcl nx56c la-chassis_14f1_tda11145ps-n3-3_tyea1533p_stv9302b_tv_sm
 
Avtron IR Bullet Camera Aa 4544-6044 p-fsr2-manual
Avtron IR Bullet Camera Aa 4544-6044 p-fsr2-manualAvtron IR Bullet Camera Aa 4544-6044 p-fsr2-manual
Avtron IR Bullet Camera Aa 4544-6044 p-fsr2-manual
 
Ampeg GVT5W 5W Class A Elektro Gitar Amfi Kafası manual kullanim klavuzu
Ampeg GVT5W 5W Class A Elektro Gitar Amfi Kafası manual kullanim klavuzuAmpeg GVT5W 5W Class A Elektro Gitar Amfi Kafası manual kullanim klavuzu
Ampeg GVT5W 5W Class A Elektro Gitar Amfi Kafası manual kullanim klavuzu
 
Tascam porta 02 manual
Tascam porta 02 manualTascam porta 02 manual
Tascam porta 02 manual
 
Kubota gr1600 ec2 ride on mower service repair manual
Kubota gr1600 ec2 ride on mower service repair manualKubota gr1600 ec2 ride on mower service repair manual
Kubota gr1600 ec2 ride on mower service repair manual
 
Kubota gr1600 ec2 ride on mower service repair manual
Kubota gr1600 ec2 ride on mower service repair manualKubota gr1600 ec2 ride on mower service repair manual
Kubota gr1600 ec2 ride on mower service repair manual
 
Ampeg GVT15H Class A Elektro Gitar Amfi Kafası manual kullanim klavuzu
Ampeg GVT15H Class A Elektro Gitar Amfi Kafası manual kullanim klavuzuAmpeg GVT15H Class A Elektro Gitar Amfi Kafası manual kullanim klavuzu
Ampeg GVT15H Class A Elektro Gitar Amfi Kafası manual kullanim klavuzu
 
Avtron IR Bullet Camera Aa 4547 p-6047-fsr4-manual
Avtron IR Bullet Camera Aa 4547 p-6047-fsr4-manualAvtron IR Bullet Camera Aa 4547 p-6047-fsr4-manual
Avtron IR Bullet Camera Aa 4547 p-6047-fsr4-manual
 
Ds 150 operation
Ds 150 operationDs 150 operation
Ds 150 operation
 
Avtron IR Bullet Camera Aa 4545 p-6045-fsr3-manual
Avtron IR Bullet Camera Aa 4545 p-6045-fsr3-manualAvtron IR Bullet Camera Aa 4545 p-6045-fsr3-manual
Avtron IR Bullet Camera Aa 4545 p-6045-fsr3-manual
 
User manual dukane 8957,8958, 8959
User manual dukane 8957,8958, 8959User manual dukane 8957,8958, 8959
User manual dukane 8957,8958, 8959
 

Recently uploaded

Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
amitlee9823
 
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Christo Ananth
 
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
dharasingh5698
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
dharasingh5698
 
notes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptnotes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.ppt
MsecMca
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
dollysharma2066
 

Recently uploaded (20)

Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
 
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELLPVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
 
Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdf
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 
Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
 
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
 
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdf
 
notes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptnotes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.ppt
 
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdf
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
 
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank  Design by Working Stress - IS Method.pdfIntze Overhead Water Tank  Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
 
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
 

hitachi_v-209_oscilloscope intruction manual.pdf

  • 1. MODEL V-209 OSCILLOSCOPE ------ .._...__ - OPERATION MANUAL ~Hitachi Denshi.Ltd.
  • 2. ,;-- ·--------·---------·-- -. ---.-·--._-----·---------1 If WARRANTY ,f ~ ~ 1 Th1s H1tach1 Ocnsh1. Ltd. product 1s warranted against defects in workman- { I { sh1p and materiah. If any failure. re~uhing from a defect in e1ther workman- , ship or matenal. ~hall uc..:ur un:ll!r uormal use within one year from the ~ J origmal date ot purcha~c. such failure shall be corrected free ofcharge to the f '1 ongmal purcha~e by repair or. at Ihtachi Denshi's sole option. replacement of ~ ){ the defective part or pam 'o charge shall be made for labor or services L( pcrfonned dunng Stlld one year period providing the product is brought to I 1 ( our AuthoriLcd Service St<lllun. ~l ) llitachi Ocnsh1. Ltd. further warrants to the original purchaser that upon ~~ ( expiration of the one year free SCI'Ice "'arranty period and within two years r I, from the original date of pun;has~ H11ach1 Dcnshi. Ltd. will e1ther repa1r ~~ 1: llr • .11 1ts sole uptu1n, rcpl:lcr an) part Ccept for cathode ra~ tube. fuses. ll , probes. lamps. batterio: and otha optional materials which are defective in 1 ~ euher worl..mamhip or rnatenal under n•mnal and proper use. t! } ..Iter the expiration ut the one ~car free '>CI'ii'e period and during the addi- ll 1 ' tiona) penod 'overed by two year~ pans warranty. a reasonable charge will 1 1~ be made for labor or ~en1.:e perfom1eJ. t' ll ThiS warranty does not cover equipment which has been tampered with in ll 1 any way. or damage caused by acc1dent, negligence, alteration, or misappli· 1 r cation. ll 1 ' This product mu~t be returnt:d transportation prepaid, properly packed and r r~ insured. This warranty apphes only to the ongmal purchaser. ~~ '~ NO OTHI:.R WARRANTILS 1Rl~ EXPRI:.SSED OR IMPLII:.D. Huachi ~~ ~ Denshi. Ltd. IS NOT LIABLI:: l-OR CONSEQUENTIAL DAMAGES. r ~ ~ t l,...,,:...,:_, ,,..., ,...,_;:"'N':,,..,,;"•";,..,,-...,..,..;:-..-..:!*Iot''•"''•''"'''••lllt......,..,ltllh·',.,.,,.....,~·u~"A""- '"'"" ., ''"''" ,...,."""•""'",.oi+l+•;"~:;,...,,:•..,..,,.tt,.';~.....,;"ltiO:,.,",:"~'+II!t!o'"'";;,.,,:"''~•ltH•.....,,.,,,. •· ''"''
  • 3. CONTENTS Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I 3. Precautions ............................ . . ................. 2 4. Controls and connectors . ................................. . .. 6 (I) Power supply and CRT . ... ........... ..... ................ 6 (2) Controls of vertical deflection system........................ . . . I0 (3) Controls of horizontal deflection system............. ............ 12 (4) Synchronization system ................................... 13 (5) Miscellaneous........................... . . . ............. 15 5. Battery operation ......... . . ........... . ...... . ...... . .... .. 15 6. How to produce the bright line ....... . ........... .. . ............ 17 7. Method for connecting signal s .................... ....... . ...... 19 8 Measuring procedure . . . .. . . . . . . . . . . . . • . . . . . . . . . . . . . . . . . . . . . . ., ., (I) DC voltage measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • . . ., 1 (2) AC voltage measurement.... .. ..... ....................... 22 (3) Measurement of frequency and penod ........................... 23 (4) Measurement of time difference.. ............................ 23 (5 ) Measurement of rise(fall)tll1le ................................ 24 (6) Synchronization of compte ed waveform ... ... .................. 25 (7) How to use TV exclusJve synchronization ........................ 25 9. AdJUStments . ............ ... ......... .. ......... . ...... 27 10. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 II. Specifications. . . .......................... . ........ .. ...... 2 12. External view .............................................. 32 13. Schematic diagrams............. . ............................ 33 14. Optional accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • . 42 MODEL V-209
  • 4. NOTE This instrument should be adjusted at an ambient temperature of +20°C for best overall accuracy. Allow at least IS minutes warmup before proceeding. c Polyvinyl chloride (PVC) film is attached on the enclosure and the front panel of the oscilloscope to protect the metal surface. If the PVC film is damaged by scratches, remove it. To clean the enclosure or the front panel, use neutral detergent. Refrain from using thinner, bent.me. alcohol or other chemicals. For safety operation, the instrument chassis and cabinet are sure to con­ nect the ground lead of the G D (ground) terminal to earth ground, if a two-wire AC power system is used. Failure to complete the ground system may allow the chassis and cabinet of this instrument to be elevated above ground potential and pose a shock hazard.
  • 5. 1. FEATURES The Hitachi V-209 is a handy-type, advanced-class oscillo­ scope with a bandwidth of DC to 20 MHz designed with the emphasis on operability and portability and has a following features. (I) Wide bandwidth: The instrument has a bandwidth from DC to 20 MHz. (2) High sensitivity: Sensitivity is I mV/div (3) 3.5-inch screen: Employment of an internal graticule CRT permits the waveform observation to be made without parallax error. (4) 3-way operation: The instrument is operated with AC-line,external DC and Battery Pack AD-209. (5) TV synchronization: Employment of a new TV sync separator circuit allows the instrument to observe TV signals stably. (6) Auto focusing: Focusing shift is automatically corrected. 2. ACCESSORIES This instrument is shipped with the following standard accessories. 2 Probes (AT-JOAK 1.5) Fuse 1A for I OOV set or 0.5A for 200V set Fuse 2A for DC line AC power supply cord DC power supply cord Operation manual.
  • 6. 3. PRECAUTIONS Precauuon� to be observed to lengthen the service life of :hb 10 trument. In tallation site • ,vo1d tnstalltng mstrument in an extremely hot or cold place. Avoid placmg this instrument in a place exposed to sun­ light for a long period of time, in a closed car in mid­ summer, or near a room heating device such as a stove. The operatmg maximum ambient temperature is +50°C. • Do not use mstrument that has been left outdoors on a cold Winter day. The operatmg ambient temperature is 0°C or more. • Avoid moving the instrument rapidly from a hot place to a cold place or vice versa, or condensation may form on ms1de of the instrument. • Keep the instrument away from damp air, water, and dust. L'nexpected trouble may be caused when the instrument is placed an a damp or dusty place. The operating ambient humidity is 35 85�. Since an accidental antrusion of water may also cause troubles, do not place a water-filled containers such as a vase on the oscilloscope. • Do not place the instrument in a place where vibration is strong. Avoid using the instrument at a place vibrating violently. Since the oscilloscope is a precision instrument, excessively strong vibrations may cause damage. • Do not place the anstrument near a magnet or magnetic body. An oscilloscope is an equipment using electron beam Therefore, do not bring a magnet close to the instrument or do not use the instrument near an equ1pment generating strong magnetic force. Handling • Do not put a heavy objects on the oscilloscope. • Do not block the ventilation holes.
  • 7. * Do not apply a heavy shock to the oscilloscope. * Do not insert a wire, pin, etc. through the ventilation hole. * Do not drag the set, leaving the probe attached to it. * Do not leave a hot soldering iron on the cabinet or the screen. * Do not try to turn the instrument upside down. Otherwise, knobs may be broken. �b� * Do not use the instrument upright, leaving BNC cable connected to EXT BLANKING terminal on the rear panel. Otherwise, the cable may be damaged. Handle The handle of the V- 209 can be positioned for carrying or as a tilt-stand for the instrument. To position the handle. press in at both pivot points and tum the handle to the desired position. 15 positions are provided for con­ venient carrying or viewing. 3
  • 8. When not in U!>e When not m u:.e, put the dust-proof cover on the mstrumcnt aud store 11 with care. When Operation is faulty Recheck the operating procedure and if problem persists. contact a nearly service station or agent. Care and repair Removal of stam from the case. When the outs1de of the case is stained. remove the stain hy first wiping 11 lightly with a cloth moistened v.ith neutral washmg agent and then w1pe the surface w1th a dry cloth. • 'ever use strongly volatile agent such as bentine and tl mner When the panel surface is stained, remove the stain in sm1ilar way with a clean, soft cloth. When heavy stains are present, first remove the stains by w1pmg the surface lightly with a cloth moistened with diluted neutral wash­ ing agent or With alc.:ohol and then wipe thoroughly with a dry cloth. When dust has accumulated on the inside, remove it by using dry brush. or by using the exhaust of a compressor or a vacuum cleaner. NOTE: When opening the case. pull out the power suppl] plug beforehand without fail When cleaning the inside, insure beforehand that no electricity remains in the condensers of the power supply circuit. • Cleaning of CRT 01rty surface of CRT screen tends to cause measuring errors The screen surface becames v1sible when the bezel is remO­ ed. Remove the stains on CRT and filter by using a clean and soft cloth, paying attention not to impair them. When the stain is extremely heavy. wash them with neutral
  • 9. washing agent and then leave them stand until the moisture is removed naturally. o If the screen is installed while it is moistened, water rings may be formed and the wavefom1 may be blurred to make observation hard. Pay attention not to leave finger prints on it. To dismount it, pull it toward you pressing it at the both ends. Operation precautions Bcz:el * Check the line voltage is in the range specified in the table below. Rating Allowable line voltage (50/60Hz) ACIOOV AC90V 130V AC200V ACI80V 260V Usually the voltage selector switch on the rear of the V-209 has been set to IOOV AC at the factory. When this is operat­ ed on 200AC voltage, set the selector switch to 200 V AC. (Rated voltages are marked above the power connector on the rear panel.) * Use only specified fuses In order to protect the circuit against over-current, a 0.5A (in primary side of power circuit) and 2A (in secondary side of power circuit) are used. When the fuses blow out, check thoroughly the cause. repair any faulty point present. and then replace them with specified fuses. Do not try to use the fuse other than the specified ones. Otherwise, fault may be caused or danger may be invited. (Particularly. do not use a fuse different from the specified one in current capacity and in length.) The standards of the fuses are as follows. Shape JIS type name {Diameter x length) mm 2A 6.35cf> X 31.8 MF6JNM250V 2A AC lA 6.35¢ X 31.8 MF61 M250V lA AC 0.5A 6.35¢ X 31.8 MF61 M250V 0.5A AC * -(negative) terminal of EXT DC I is inside connected to case ground. Do not connect - (negative) terminal of the V-209 to the + (positive) grounded case of other instru­ ments with common external DC power source to the V-209. If not, it is very dangerous because a large current nows through the grounded line. 5
  • 10. 6 V-209 Grounded line Other in�trument Common external DC power source < DANGEROUS CONNECT> * Do not apply rever e polarities to EXT DC IN. • Do not mcreasc the bnghtness too much. Your eyes rna) be steamed and the nuorescent surface of CRT may be burnt. • Do not apply an excel;sive voltage. The maximum volt3ge of each input is as follows. PUT direct 250V (DC+ peak AC 3t I kilt.) When xI0 Probe is used 250V (DC+peak AC at I kilt.) E T TRIG INPUT 250V (DC+peak AC) EXT BLA Kl G SOV (DC +peak AC) 4. CONTROLS AND CONNECTORS (I) Power supply and CRT Operating voltage and fuse Thts model can be operated from e11her 3 100 volts or a :!00 volts nominal line vohage source. The line voltage select switch on the rear panel, turn the instrument from one operating range to the other. In addition, this switch changes the primary connections of the transformer to allow selection of one of two regulating ranges. Use the following procedure to convert this instrument between normal line voltage or regulating ranges a. Disconnect the instrument from the power source. b. To convert from I 00 volts nominal to :!00 volts nomi­ nal line voltage or vice versa, remove the protector of the line voltage select switch. Change the line voltage select switch from I 00 volts to 200 volts and remounting the protector. c. Before apply the power to the mstrument, check that the indicating tabs on the rear panel. Selection of power supply mode This oscilloscope can make operation by using three kinds of AC power supply, external DC power supply and A[}209bat­ tery pack. T
  • 11. The S itches are set as shown in the table below to establi�h each power �upply mode Switche Po.1.-er source Power mode upplylnode select witch (J) select witch @ ---- t AC IXOP DC D OP DC t- 0 OP When charging DC BATT CI-IARGC (AD-209) *DC II to 14V IS supphed via EXT DC I PUT connector. <WARNING> After completing the charge of AD-209, be sure to set power mode select sw1tch to DC OPE. When the output voltage of DC power supply becomes less than IIV. the power lamp 1 blmking. When the output 'Oitage 1s less than approx I0.5V. it stops the operauon to prevent the battery ovenltscharge. When mstrument is operated by u�ing the AD-209, refer to chapter 5, "Battery Operation." n When the AD-209 IS not used, it is possible that the CIIARGE lamp is illummated by setting the Charge mode. Lxternal DC operation The V-209 can be operated by e'temaliX l>Ource (II to 14 volts) In tillS case, DC source IS supphcd by the attached external DC ource cable. Connect the whtte hne of source cable to plus(+) s1de Reversing polanty connecuon may cause blow of the fuse D-209 and external DC source are automatically switched by mserting the external DC source cable into EXT DC INPUT connector. 7
  • 14. CD POWER switch After checking the line voltage select switch, set POWER switch set to OFF and then connect the AC cord to AC wall socket. (}) POWER lamp This lamp goes on in red when the power supply is in ON state. G) CHARGE lamp This lamp goes on in red in the battery charge mode. When the battery is completely charged, this becomes dim. @) FOCUS control After obtaining an appropriate brightness by operating INTENsity,adjust FOCUS until the bright line becames clearest. Although the focus is also corrected automati­ cally when INTEN is rotated, the focus is sometimes slightly shifted. @ TRACE ROTATION control Used to align the trace of CRT with the horizontal graticule. @ INTENsity control JO Works as the brightness adjustment. Brightness is increas­ ed by rotating INTENSsity clockwise. (j) Power source select switch Used to select the power sources. AC Operated with the AC power source DC Operated with the AD-209 or external DC power source ® Power mode select switch Used to select the power mode. See Selection of Power supply mode. <CAUTION> Do not set the Power mode select switch to the BATT CHARGE except charging batteries. ® EXT DC INPUT connector See External DC operation. (2) Controls of vertical deflection system @ CH 1 INPUT connector B C connector for vertical axis input The signal input to this terminal becomes the X-axis sig­ nal when the instrument is used as an X- Y oscilloscope.
  • 15. @ CH2 INPUT connector Thr same as CHI, but when the instrument is used as an X- Y oscilloscope, the signal input to this terminal becomes the Y-axis signal. @@ Input coupling switches (AC-GND-DC) Used to select the coupling system between the input signal and vertical axis amplifier. AC At this setting. the signal is connected through a condenser. The DC component of the input signal is cut off and only the AC component is dis· played. GND At this setting, the input to the vertical axis ampli­ fier is grounded. DC At this setting, the input signal is directly con­ nected to the vertical axis amplifier and displayed unchanged, including the DC component. � @ VOLTS/DIV select switches A step attenuator which selects vertical deflection fac­ tor. Set it to an easily observable range corresponding to the amplitude of the input signal. Multiply the reading by I 0 when the I 0: I probe is used in combination with the instrument. @@ VARIABLE controls Fine tuning device is used to vary the vertical deflection sensitivity continuously. Attenuation of less than 1/2.5 is obtained when this device is rotated in the reverse direction of the arrow to the full. This control is used when comparing wavefom1s or when measuring the rise tinle of a square wave in 2-channel observation. Normally this control is left rotated in the direction of the arrow to the full. @@ POSITION controls Used to adjust the position of the vertical axis. The image rises with the clockwise rotation of this knob and falls with the counterclockwise rotation. When the knob is at PULL position, (pulled up state) the gain of the vertical axis is magnified 5 times and the maximum sensitivity becomes I mY/DIY. @ MODE select switch Used to select the operation mode of the vertical deflec­ tion system. CH J Only the signal that has been applied to CHI appears on the screen. CH2 Only the signal that has been applied to CH2 ap­ pears on the screen. J 1
  • 16. ALT Signals applied respectively to CHI and CH2 appear on the screen alternatively at each sweep. This setting is used when the sweep time is short in 2-channel observation. CHOP At this setting, the input signals applied respec­ tively to CHI and CH2 are switched at about 250 kHz independent of the sweep and at the same time appear on the screen. This setting is used when the sweep time is long in 2-channel observation. ADD The algebraic sum of the input signals applied respectively to CHI and CH2 appears on the screen.. @ CH2 INV button 12 Used to inverse the polarity of the input signal applied to CH2. Inversion occurs in a state where the knob of the pushbutton is depressed ( _o._ ) and restored to normal when the knob is in protruded state ( _0_ ). This switch is conveniently used in the comparison of two waveforms having different polarity or in the observation of the waveform of the difference signal !CHI l - !CH2 I between CHI and CH2 using ADD. (3) Controls of horizontal deflection system @ TIME/DIY �lect switch Sweep time ranges are 18 steps from 0.5 psjdiv to 0.2s/ div. X-Y This position is used when using the instrument as an X-Y oscillsocope. In this position, the X (horizontal) signal is con­ nected to the input of CH1; · the Y (vertical) signal is applied to the input of CH2 and has a deflection range from less than one millivolt to 5 volts/div at a reduced band-width of200 kHz. @ SWP VARiable control Works as CAL and the sweep time is calibrated to the value indicated by TIME/DIY. TIME/DIV of sweep can be varied continuously when shaft is out of CAL position. Then the control is rotated in the direction of arrow to the full, the CAL state is produced and the sweep time is calibrated to the value indicated by TIME/DIY. Counterclockwise rotation to the full delays the sweep by 2.5 times or more. @ FINE PULL xlO MAG :::POSITION control Used to move the bright line in horizontal directions.
  • 17. It is indispensable to the measurement of the time of waveform. Bright line is moved toward right when the knob IS ro­ tated clockwise and toward left with counterclockwise rotation. The outer shaft is for coarse adjustment and the inner shaft for fine adjustment. @ x 10 MAG control A and B sweeps are magnified I0 umes by pulling out FINE knob (inner shaft) of POSITION. In this case, the sweep time is I/10 of the value indicated by TIMEtDJV. Bring the position of the waveform to be magnified for observation from the center of the scale by operating =::POSITION of the horizontal axis. Next.switchxiOMAG switch to PULL (pulled out state). Then the waveform placed at the center ts magnified in right and left directions. The sweep time in this case is I 0 times of the sweep speed obtained by TIME/DIV, in other words. the reading is I 10 of the sweep time indicated. I ! I . f- y ;ft f-1- i-Ii r-1 � I I ! --'- I ! ! lf- f--+- t - ��� ._ t ; 1 I I I Magnified �--avefom1 (4) Synchronization system @ SOURCE select switch U ed to select the triggering signal source A sweep. Cll l The input signal applied to CHI becomes the trig­ gering signal CH� The input signal ttpplied to CH2 becomes the trig· gering signal. 13
  • 18. LINE This setting is used when observing a signal trig­ gering with power supply line frequency. EXT External triggering signal applied to TRIG IN­ PUT becomes the triggering signal. This setting is used when triggering with a special independency of the vertical axis signal. @ TRIG INput connector Input terminal used for external triggering signal of A sweep. @ TRIG LEVEL control 14 Used to decide at which portion of the waveform the sweep should be started by setting trigger level. This control is also enabled to switch SLOPE. Depressed position (nonnal state) is for <±>SLOPE and PULL position (state in which the knob is protruding) is for 8 SLOPE. Explanation of synchronization polarity SLOPE Push at time of @SLOPE Pull at time of 8 SLOPE Explanation of synchronization level LEVEL 0 f' ,_ At the time _ of(±) SLOPE ,-, + At the time o - ofG SLOPE - -/ @ TRIG MODE select switch AUTO Brought into automatically triggering sweep in which sweep is always conducted. In the presence of triggered signal, normal triggered sweep is obtained and the waveform stands still. In the case of no signal or out of triggering, sweep line will appear automatically. This setting is convenient in usual cases. NORM Triggered sweep is obtained and sweep is con­ ducted only when triggering is effected. No sweep line will appear in the case of no signal or out of synchronization. Use this MODE when effecting synchronization to a very low fre-
  • 19. quency signal (30Hz or less). TV(V) This setting is used when observing the enure vertical picture of television signal. TV(H) Th1s setting is used when observing the entire horizontal picture of television signal. (NOTE) Both TV V and TV H synchronize only when the synchronizmg signal is negative. (5) Miscellaneous @ EXT BLANK connector Input terminal for brightness modulation. It is of the DC coupling. The brightness is reduced with a positive signal and increases with a negative signal. @ CAL O.SV tip Output terminal of calibration square wave of about I kHz and O.SV. It has a tip terminal. It is used to cali­ brate the probe combination. @ GND terminal Earth terminal of the oscilloscope. 5. BATTERY OPERATION Operation of battery pack AD- 209 I) Set the Power source select switch (j) to DC and the Power mode select switch@to DC OP. 2) Tum on the POWER switch CD. Then the V-:!09 starts to operate on the power from the AD-:!09. The continuous operation time is one hour and half. If the battery is operated 1n excess of this period, the ter­ minal voltage will decrease sharply and the battery will be in the over-discharged condition. In this model, an alarm circuit will be activated before the over-discharging and the POWER lamp G) starts to Oash. In this case, charge the battery immediately. Note: When the alarm c1rcuit IS energized and the volt­ age is lowered down to IO.SV, the power of the V-209 is off automatically to prevent the over­ discharge of the AD-209. The selection of the AD- 209 and an external DC source is made by the external DC input con­ nector ®. 15
  • 20. Charging of battery I) (onne..:t the C cord 10 an AC outlet and set the ,(-DC swnch (J) to DC and the DC 01' BfT CIIARGL switch @ to BAIT CHARGE. :::! ) Turn on the pl)>Ner swit..:h CD and the charging will stan. In this case. the POWER lamp is not illuminated. 3) The ( 111RG! lamp Q) is bemg J!luminated dunng the �harge. II will take about IS hours until the battery is charged completely. When the charging is completed, the CHARGf lamp becomes dim. 4) When the V-109 is operated on the AC source. while it is connected with the AD- :::!09. the AD-209 is in the trickle charge mode. Operating con iderations 16 Do not short the both polarities. Do not throw the battery pack into fire. a) Charge the battery m the ambient temperature from 10 to 3S 0 C'. Do not charge the battery for three days or 4g hour in succession. This will shorten the life of the battery. b) Store the battery pack in a cool and dark place and in the ambient temperature from -IS to 35°C. When a battery stored for an e'tended period is used. chargr it for IS hours. 1.') The hfe or the battery pack IS subject to the am­ bient temperature. load cond1t1on and continuous operation. Usually. the number of the charge and discharge is over 300. If a charge and discharge is made once a day. the life will be more than one year. If the life is over, the battery can not operate nom1ally. In this case. replace the battery. d) Charge the spare battery once a month to prevent a self-discharge of the battery. AD-209 battery pack replacement procedure 1) Disconnect the power cord. 2) a) Remove four screws on the upper enclosure, then remove the upper enclosure (Refer to the Fig. a). Remove the screws and the plate shown in the Fig.b. b) Disconnect the connecwrs between the battery pack and the oscilloscope and take out the battery pack AD-209. c) Install the new battery pack AD-209 to the com­ partment as shown. ------------------------------------------------
  • 21. Then connect the battery pack connector to the connector of the oscilloscope. d) Mount the plate with screws. e) Fix the upper enclosure on the oscilloscope with four screws. Fig. a Fig. b <CAUTION> Upper enclosure , Bauery Baucry pack Battery pack fi,ing �crew AD-209 When mounting the battery pack AD-209, take care not to damage the connecting cables and components. 6. HOW TO PRODUCE THE BRIGHT LINE Before turning 0 the POWER switch. insure the power supply voltage is within the range of 90-J30V for AC IOOV set. 180 260V for AC 200V set. Insert the plug of the power cord on the rear panel into the power supply wall socket and set the controls as follows. POWER OFF INTEN Counterclockwise to the full FOCUS M1drange AC-GND-DC GND �I POSITION Midrange {the knob is left depressed ) V. MODE (Ill TRIG AUTO TRIG SOURCE CHI TIME/DIY 0.5 ms/div ::: POSITION I Midrange Set all the levers of the switches to the upper side. After ending all the setting mentioned above. turn 0 the POWER and. 15 second later, rotate the INTEN knob clock­ wise. Then the sweep bright line will appear. If the observation is to be started immediately. set the FOCUS control at a point where the bright line is sharpest. 17
  • 22. If the instrument is not used with the power supply turned on. rotate the I TENsity counterclockwise to reduce the brightness and also blur the FOCUS. NOTE For usual observation, leave the following non-calibrating function section set to ''CAL" position. VARIABLE Rotate in the direction of arrow. In this case, the VOLTS/DIV is calibrated to its indicating value. SWP VAR Leave the knob in depressed state. In this case, the TIME/DIV is calibrated to its indicating value. Align the bright line with the horizontal scale line at the center of the screen by operating CHJ POSITION. In some cases,the bright line may be oblique to the scale slightly by the effect of earth magnetism. In this case. bring the bright line until it lies on the horizontal scale line at the center of the screen by properly adjusting the semi- Gxed variable resistor TRACE ROTATION on the front panel. 18 GENERAL MEASUREMENT (I) I n the case of observing a single waveform. Use CHI or CH2 when not observing the phase difference between two waveforms or when engaging in a operation other than X- Y operation. Make the following settings when using CHI . MODE Switch of Vertical defection system CHI MODE Switch of TRIG AUTO TRIG SOURCE CHI Under these settings, almost all the repetitive signals of about 30 Hz or more applied to CHI can be synchro­ nized and observed by adjusting TRIG LEVEL. Since the MODE of horizontal axis is at AUTO position, the bright line appears even when no signal is present or when input coupling switch is at GND position. This means that the measurement of DC voltage can be measured. The following switching is needed when observing low fre­ quency signals of about 30 Hz or less. MODE of TRIG ORM Synchronization can be effected by operating LEVER knob under this setting. When using only CH2, use the instrument after making the following settings.
  • 23. MODE Switch of Vertical Axis TRIG OURCE (2) When observing two wavefonns CH2 CH2 Observation of two wavefom1S can be made easily by setting the MODE switch of vertical axis to ALT or CHOP. When observing two wavefonns of high repetition frequen­ cies, set the MODE switch to ALT and, in the case of low frequencies, set it to CHOP. Measurement of the phase difference is performed after effecting synchronization with leading phase signal. (3) When observing wavefonn with X- Y Set the MODE switch of vertical defection system to CH2 (X- Y) and TIME/DIV switch to X- Y. Then the instrument works as an X-Y oscilloscope. Each input is applied to the instrument as follows. X-axis signal (horizontal axis signal) Y-axis signal (vertical axi� signal) CHI INPUT CH2 INPUT In this case.leave the horizontal axis magnification switch (PULL-MAG x 10 inner shaft knob) at depressed position. 7. METHOD FOR CONNECTING SIGNALS The first step of measurement is to introduce the signal desired to measure to the oscilloscope properly. Do it with utmost care. (I) When using a probe Use the attached probe, AT-I 0 AK I .5, when measuring a high frequency wave with high accuracy. It should be noted, however, that since the input signal is attenuated by this probe to 1/10 before it is input to the oscilloscope, the use of the probe is disadvantageous for low signals, and that at the same time, the measuring range is extended by that amount for high signals. <CAUTIONS> o Do not apply a signal which exceeds 250V (DC+ peak AC at I kHz). o Bring the grounding point of the earth lead wire of the probe close to the point to be measured when measur­ ing a rapid rising signal or a high frequency signal. Long earth lead wire may cause wavefonn distortions such as ringing and overshoot. 19
  • 24. Connection of earth lead wire 20 (a) A good example (b) A bad example For better measurement. it is required to use an earth attachment available at option. Multiply the reading of VOLTS DIY by 10. For example. if the VOLTS/DIY ts SOmV/DIV. then read the wavefonn as SOmV/DIV x 10 = SOOmV/DIV o To avoid measurement error, put the probe in the follow­ ing correction state and check it before measurement without fail. Connect the tip of the probe to the output tenninal CAL O.SV of I kHz calibration square wave voltage. When this correction capacity value is at optimum,the wavefonn takes the shape as shown in Fig. (a) as follows. If the wavefonn is as shown in Fig. (b) or Fig. (c), rotate the semiftxed adjusting screw on the matching box of the probe by using a screwdriver until the opti­ mum state is obtained. L Capacitance correction trimmer JliUlJ1 MJUl MM (a) Optimum (b) Capacity too small (2) At time ofdirect connection (c) Capacity too large When connecting a signal directly to the oscilloscope not usmg the attached probe AT-10 AK 1.5 (IO· 1 ), pay atten­ tion to the following points in order to minimize the mea­ surement error. o When perfonning observation using a bare lead wire, no trouble occurs on the circuit to be measured at low impedance and high level. However. note that, in most cases. measurement error may be caused by static stray coupling with other circuit and power line. This measurement error cannot be ignored even in low frequency region.
  • 25. In general. tt tS safe to avoid measunng with non­ shielded connecting wire. When using a shieldmg wire, connect one end of the shield to the earth terminal of the oscilloscope and the other end to the grounding of the circuit to be measured. It is deirable to use a coaxtal cable with B C type connector. The following cautions must be observed when per­ forming a wide band measurement. It ts necessary to terminate with the characteristic impedance of the cable when measuring a rapid nsing waveform or a high fre­ quency wave. Especially when using a long cable. the absence of a terminating resistor will necessarily lead to a measure­ ment error derived from ringing phenomenon. Some measunng circutls require a termmating reststor equal to the charactensttc unpedance of the cable also on the measurement terminal stde. B C type terminating reststor (50 Q) ts conveniently used for this purpose. c In order to perform measurement with the measuring circuit put in proper operating state, it is sometimes necessary to terminate the cable with an impedance which corresponds to the circuit to be measured. o The stray capacity of the shield wire must be taken in10 account when performing measurement with a long shield wire. Since the shield wire normally in use has a capacity of about I 00 pF per meter. its effect on the circutt to be measured cannot be ignored. Use a probe to minimize the cffection the circuit. When the length of the shield wire is used or when the length of the non-terminated cable reaches I 4 wave length or its multiples within the band of V-:!09 type (I 4 wave length is about 3 meter when using a coaxial cable at }0 MHz), oscillation may be caused near 5 mV DIY range. This is caused by the resonance between the externally connected high-0 inductance and the input capacity and can be avoided by reducing the Q. Connect the cable or shield wire to the input connector by way of a senally connected I OOU to I n reststor, or perform measurement at other VOLT/DIY range. 21
  • 26. 8. MEASURING PROCEDURE The first things to do are as follows. o Bring the brightness and FOCUS at optimum positions for easy read out. � Display the waveform as large as possible to minimiLe the read error. Check the capacity correction when using a probe. (Refer to paragraph (I) "When using a probe" of Sec­ tion 7. "Method for connecting signals" for correcting capacity.) (I) DC voltage measurement Set input coupling to G D and decide the zero level prop­ erly. Set VOLTS/DIV appropriately and set AC-G D-DC to DC. Since the bright line shifts here by the amount of DC voltage, the DC voltage of the signal can be obtained by multiplying the shift width by the indicated value of VOLTS/DIV. When VOLTS/DIY is 50 mV/DIV, then SO mV/DIV x 4.2 = 210mV (However, if the probe AT- 10 AK I .S (10:1) is in use, the true value of the signal be­ comes 10 times of the value, or SO mV/DIV x 4.2 x 10 = 2.1V.) DC voltage (after shifting) Zero level (reference line) (2} AC voltage measurement The same as paragraph 8 (1). "DC voltage measurement", but here there is no need of align the zero level with the scale line. Set the zero level to the position that can be easily observed. In the drawing as follows, VOLTS/DIV is IV/DIY, IV/ DIY x S = S Vp-p (SOVp-p at time using the probe AT- 10 AK 1.5(10: 1)). When magnifying and observing a small­ amplitude signal, superimposing on a high DV voltage, set the input coupling to AC. The DC voltage is cut off and AC voltage can be observed by increasing sensitivity.
  • 27. r /f - - - - �ff-- 1 I 1 17 1 H--+--f--t-1-t-+---+-_+=1_-- --- (3) Measurement of frequency and period This will be explained with the following figure. One period covers the time A and time B, which are sepa­ rated from each other by 2.0 DIY on the screen. When the sweep time is Ims/DIY, the period is given by 1 ms/DIV x 2.0 = 2.0 ms =2.0 X 10-3 S Accordingly, the frequency is 1/(2.0 X J0- 3 )= 500Hz (However, when the knob MAG x!O is at pulled out posi­ tion, TIME/DIY must be converted to I /10 since the sweep is magnified.) I- +- -1 - -I- � . * • - ------- - 71 f/ l I- T II 711/ I rr ., u -- - - Time A Time B II --- 1 - -lh__: v� I- (4) Measurement of time difference Triggering signal source ''SOURCE" is selected as an offer­ ing reference signal when measuring the time difference be­ tween two signals. Assume that pulse trains as shown in (a). Then (b) shows the case when CHI is taken as the triggering signal source and (c) the case where CH2 is taken. I I CH I � CH2 �­ �- (a) (b) I I -_I ,-+- .:::. CH :..:...:.. I __ _ I CH2 (c) 23
  • 28. 24 This means that CHI is used as the triggering signal when investigating the length of time by which the signal of CH2 is delayed from the signal of CH 1. CH2 is used in the reversed case. In other words, the signal leading in phase is selected as the triggering signal source. If this process is reversed, the portion to be measured may sometimes not appear on the screen. Thereafter, equalize the amplitudes of the two signals appearing on the screen or superimpose one on another. Read the time difference between 50% amplitude points of the two signals. Sometimes the superimposing method is more convenient from the point of view of procedure. � it ' --- - � Time => difference Equalize "' � �amplitudes -----J_-:;- by VAR (a) Equal amplitude measuring method <CAUTIONS> (b) Suerposition measuring method Since the pulsed wave contains many high-frequency wave components (higher harmonics) depending on its width or period, pay the same attention as given to high frequency signals when handling it. Accordingly, use a probe or coax­ ial cable and shorten the earth lead wire as much as possible. (5) Measurement of rise (fall) time To measure the rise time, pay attention not only to the abovementioned items but also to measurement error. The following equation is provided for the relation among the rise time Trx of the wavefom1 to be measured, the rise time Trs of oscilloscope, and the rise time Tro displayed on the screen. Tro =../Trx2 + Trs2 When the rise time of the pulse going to be measured is sufficiently longer than the rise time of the oscilloscope (17.Sns in our case),the effect of the rise time of the oscil­ loscope on the measurement can be neglected. However, if both are close to each other, measurement error may be caused. The true rise time is given by Trx = .../Tro2 - Trs2 Moreover, in general, in a circuit free from waveform dis­ tortion such as overshoot and sag, the following relation­ ship is established between frequency band and rise time.
  • 29. fc x tr = 0.35 Where, fc: Frequency band (Hz) tr: Rise time (s) The rise time and fall time are determined by the time elapsed between the I 0'1 to 9Qc,r 'alues of pulse width. (6) Synchronization of complexed waveform In the case shown in the Fig. (a) below where two wave­ forms have difference in amplitude alternate. the wave­ form is doubled if the trigger level is not set properly. In the case where the trigger level is selected as Y line two waveforms. one starting with A and advancing to B. C. D, E. F.... and the other starting �ith E and advancing to F, G. H, I .... will appear alternately on the screen. They will be doubled as shown in Fig. (b), for which no synchro­ nization can be taken. In such a case, rotate LEVEL clockwise until the trigger level comes to Y' line. Then the waveform on the screen be­ comes the one shown in F1g. (c) above wh1ch starts with B and advances to C, E. r, . . . and which allows synchro­ niLation. /TC. .7 h/"'-� 0 � � � v J.......,. L� p= (a) Signal waveform Y' Trigger level y �Lting line (b) When the uiggcr (c) When the uigger ...:ning level •� Y selling level i' y· Synchronization of complexed waveform (7) How to use TV exclusive synchronization CD On the image waveform of TV In the work concerned w1th TV. comple:-.ed signals con­ taining video signal. blanking pedestal signal. and syn­ chronizing s1gnal are often measured. llowever, since the waveform is complexed, a special circuit IS needed 10 effect a stable syncrhonization with vertical waveform. Synchronizing signal pulse (SYNC pulse) IV (vertical) ------� 25
  • 30. 26 Q) Difference in the circuits Exclusive circuit for conventional oscillograph General circuit Video �ignal To trigger circuit Hard to synchronize, because video signal is applied directly as trigger signal. Simple synchronizing circuit To trigger circuit Synchronization is more easily effected than in the circuit shown at left, because the signal is integrated to remove high frequency components. Exclusive circuit for this instrument (Principle drawing) TV exclusive synchronizing separator circuit To trigger cucuit After picking up the SY C pulse, the vertical synchronization is separated. Then, the stable syn­ chronization is obtained.
  • 31. Q) Operation [!RIG) MODI l V-V ,TRJCJ MODI: fV-11 ( Oll ) lim Otlllmcopc ,ynchronizc� llh only (-) ,ym;hronum)! l!!nal. (REFERENCE) Video tgnal Synchronizmg signal (a) Example of(-) synchronizing signal (b) Example of(+} synchronizing signal 9. ADJUSTMENTS The ATT balance of the '-Crtkal "''scan be made easily. Qj ct the input couphng �Htchc of CIll .tiiJ CH� to G:-.:D and set the TRIG MODI to Lro. 1hen posn10n the bright line to the center. � Turn the VOLTS DIY switch to SmV IOmV and ad­ JUSt it so that the bnght line does not move (Remove the cover). CHI DC B-L -dJU'tm.:nt o l..:::.. --l-�./ ,...
  • 32. 10. MAINTENANCE 28 I) Since semiconductors, precJsJon components, etc. are employed in this oscilloscope, use atmost care for opera­ tion and storage. 2) Clean the scale with soft tissue periodically. 3) Store this oscilloscope in the ambient temperature from -15 to +60°C (except for the battery pack AD-209) . 11. SPECIFICATIONS !CRT! Type 3.5-inch rectangular CRT with internal graticule. Phosphor P31 standard Graticule 8 x 10 div (div = 6.85 mm) Internal graticule Focussing Possible (with automatic focus correction circuit) Trace rotation Brightness adjustment Present Possible IZ-AXIS INPUT (INTENSITY MODULATIO@ DC-coupled, positive-going signal decreases intensity: SVp-p signal causes noticeable modulation at normal intensity: DC to l MHz Input impedance Approximately 50 k ohm
  • 33. Maximum input voltage SOV (DC + peak AC) Coupling DC VERTICAL DEFLECTION SYSTEM (2 identic��hannet S}] Bandwidth and rise time DC to at least 20 MHz and rise time 17.5 ns or less. DC to at least 5 MHz and rise time 70ns or less at magnifier extends. The AC coupled lower -3dB point is I0 Hz or less. Deflection factor SmV/div to SV/div in 10 calibrated steps in a I 2 5 sequence. Uncalibrated continuous control extends de­ flection factor to at least 12.5 Volts per division in the 5 Volts/div position. xS MAG increases sensitivity of each deflection factor setting to I mV/div. Accuracy ±3% (+10 to +35°C) Additional error for magnifier ±2% Display modes CHI, CH2 (normal or invert), Alternate, Chopped (approximate 250kHz), Added Input impedance 1 MS1 ±1.5c;( in parallel with 30 ±3pF Maximum input voltage 250V (DC+ peak AC') or SOOVp-p A(' at IkHz or less Input coupling AC,GND. DC LHORIZONTAL DEFLECTION SYSTEM] Time base O.Sps/div to 0.2s/div in 18 calibrated steps in a I 2 5 sequence. Uncalibrated continuous control extends de­ flection factor to at least 0.5 seconds per division in the 0.2 sec/div position. xI0 MAG extends maximum sweep rate to 50ns/div. Accuracy ±3% (+IOto +35°C) AdditionaJ error for magnifier ±2% [TRIGGERING SYSTEM! Trigger modes Automatic, Normal, TV (TV-H orTV-V) 29
  • 34. JO Trigger source Internal (ChI. Ch2), Lmc, l:.:<temal Trigger slope +,- TV sync polarity TV(-) Triggering level variable range Internal: ±4 div or more External, approximately±IV Triggering sensitivity and frequency TV-V sen ithit)< SY'( scctton less than 0.7 dtv or 200mV AUTO lo"' band Approtm:uely JOH1 A trigger coupling Af · 20 II; to full bandwidth External trigger input impedance I �·.H'2 ±20• m parallel with 30 ±6pF Maximum input voltage 250V (DC+ 1C peali.) fX- Y OPERATION (CHI; Horiz. CH2. Vert� Deflection factor Same as vertical tlencction Accuracy Y ±3% (+10 to+3'0C) X: ±Srr,. (+10 to +3�0C) Additional error for magnifier ±2"' X-bandwidth DC to at least 5001i.llt Phase error 3°f or Jess from Df to I OOJ...II1 CALIBRATOR An approxtmatc I kilt frequency O.SV (+I 0 square wave
  • 35. IPOWER SUPPLY I VOLTAGE {S0/60Hz) I OOV (90 130V) 200V (180-260V) Power supply frequency: SO, 60,400Hz Power consumption: Approx. 18W FUSE lA O.SA EXT DC power supply: DC IIV-14Y Approx. 0.8A ' ENVIRONMENTI Limit of operation temperature Limit of operation humidity Rated range of use temperature Rated range of use humidity Storage and transport temperature fDIMENSIONS AND WEIGHTI Approx. 215(W) x IIO(H) x 330(0) mm (8.6(W) x 4.4(H) x 6.4(0) inch) 35 85% 45-85% -20-+70 ° C Approx. 4.5 kg (10 lbs) joptionI Accessory pouch Hood Shoulder belt IAD- 209 type Battery� Batteries Nominal capacity Nominal voltage I0 rechargeable A nickel-cadmium cells 1800 mAh 12V Battery execessive discharge protection Instrument operation automatically interruped when battery charge drops to approximately J O.SY. Charge current Approx. 180 rnA Charge time 13-16 hours for full charge 31
  • 36. 1 2. EXTERNAL VIEW 32 TOP YiC� ...... .. • • 00 000000 0 0 ··� SIDE view UniL: mm '10DEL V- 209
  • 37.
  • 38.
  • 39.
  • 40.
  • 41.
  • 42.
  • 43.
  • 44.
  • 45.
  • 46. 14. OPTIONAL ACCESSORIES Shoulder belt 1. Check the following parts packed along with the should­ er belt (No. 8101) in the Polybag. a) Binding screw M3 x 6 (Code XCA6306) . ... .......... Four pieces b) Triangle clasp (0#8301104) . . . ... ........ Two pieces c) Clasp (D#x8301102) Two pieces d) Belt (D#x876416) ................One piece 2. Mounting 42 To carry the model V-209 oscilloscope with the should­ er belt hanged up, execute the hooking of the shoulder belt (No. 8101) as follows. I ) Mount the triangle band clasps on the positions shown in the figure, using the screws a). 2) Then, hang the clasp mounted across the shoulder belt (No. 8101) into the triangle clasps mounted as 1). Accessory pouch Mount the accessory pouch to the model V-209 oscilloscope. I) Insert the edge Q) of the accessory pouch into the body (!)•. 2) Bend the accessory pouch and insert the section Q)into G)·.