1. Fadi Suleiman Al-Zatari
Electrical Protection Engineer
Objective
An electrical engineer with good experience in electrical power system protection relays testing
and maintenance, control scheme troubleshooting and a good background in power cables and
renewable energy systems. Is looking for an opportunity to work as a protection testing and
maintenance engineer
Personal Information
Mobile: (Jordan) +962799742348
Email: zatarifadi@gmail.com
Date of Birth: 15, May, 1986
Nationality: Jordanian
Address: Amman, Jordan
Marital Status: Single
Education
Bachelor Degree: Electrical Power Engineering
University: Al-Balqa Applied University (Polytechnic College)
Accumulated Grade: Good
Graduation Year: June, 2009
Graduation Project: Renewable Energy System, Consist of Load Calculation, Distribution
Design and Protection, with manufacturing the Electrolyzer Device.
Project Grade: Very Good
Skills and Qualifications
Authorized Protection Engineer in National Electric Power Co,(NEPCo), Jordan to work
in the energized substations in different voltage levels, starting from 6KV to 400 KV
Good experience in testing and commissioning of power system protection relays and
control system.
Good experience in the maintenance of the protection systems, including the transmission
line protection, Transformer protection, Bus-Bar protection, 33kv feeder’s protection, etc.
Trouble shooting in protection and control schemes, trouble shooting in operating
equipment’s and devices.
Skill in operation of static and digital relays. Interface knowledge to communicate
to relays by manual and computer operated software methods to change the operating
settings as per system requirements.
Good background in power cables manufacturing, testing and types.
Good knowledge in renewable energy systems.
2. Experience
National Electricity Power Company ( NEPCo).
As a Protection Maintenance and Commissioning Engineer
Testing and commissioning of HV equipment’s like CT, VT.
Detailed work on protection schemes, tripping schemes, etc.
Authorized to work in energized substations.
Testing and maintenance for different types of protection relays, like
• (O/C, E/F) (Directional or non-Directional) relays like
(SPAJ140,SPAD/ABB, KCGG142/ALSTOM, 7SJ52/SIEMENS,
MiCOM/ALSTOM, REX/ABB, etc.),
• Distance Relays like ( MiCOM P437,P441,P442,P443, REL521,670/ABB,
Siemens 7SA511/7SA513/7SA522 ,MICROMHO, Quadromho/ALSTOM,
SEL 321, etc.)
• Differential Relays like ( MiCOM P631,P632 , 47UT613 Siemens , SPAD
346/ABB 670 etc.)
• BB protection relays, breaker failure relays, trip circuit supervision
relays, auto reclose relays, Pilot Wire Protection, etc.
REF Stability and diff stability tests schemes for power transformer, Busbar stability and
sensitivity test schemes, cable differential schemes, single and double bus bar schemes
arrangement
Operating experience of different types of testing and calibrating equipment’s on primary
injection and secondary injection, like SVERKER 760, FREJA300/programmer, high
AC and DC injection set CPC100/Omicron, CMC 156/256 Omicron and Megger SMRT
36.
Completed Projects:
Al-Salt Substation Extension 132/33 KV.
IPP4 Substation 132 KV ( Power Plant Substation Includes Four GT’s)
IPP3 Substation 400 KV, still.
IPP1 400KV Substation ( The Distance Protection Relays in Main 2
Protection Panel has been Replaced to Line Differential Relays and Modified
The As Built Scheme for OHL1 and OHL2).
Programming The Fault Recorder Devices Type Hathaway-IDM, in Several
Power Substations.
Extension Project for Airport Substation ( 33kv/11kv fedeers).
Do the Annual Maintenance Works for Power Substations, for All Protection
Kinds and All Types of Protection Relays.
Do replacement for old relays version with Siemens relays type: 7SJ80 in
several substations.
3. Training
SGS GROUP JORDAN:
Internal Audit and ISO 9001:2008
Training on the protection relays type MiCOM. Schneider by Schneider Electric
Factory in Shanghai, China.