1. CURRICULUM VITAE
Personal details
Name : S.VINCENT
Date of Birth : 21.01.1986
Nationality : Indian
Sex : Male
Marital Status : Single
Languages Known:
English,Hindi,Tamil
Passport Details :
Passport Number : G 1024078
Date of Expiry : 05.12.2016
Contact Details :
Mail ID:
vin_centstar123@yahoo.co.in
Contact No: +966-562846032
+91-9865406645
Objective
With an experience in the field of Testing and
Commissioning of power system products, I look forward for an
opportunity to display my skills in the field of Testing,
commissioning, Substation Automation Systems, Design,
Operation & Maintenance and Execution of projects related to
power systems.
Educational Details
Completed in H.S.C. in (2002-2003) 74% From Punitha
Arockia Annai Hr.Sec.School Keeranur.
Completed in D.E.E.E in (2003-2006) 79% From Srinivasa
Polytechnic College Kalamavur.
Skill Set
Having an experience and knowledge in Testing and
Commissioning of all electrical equipments through VOLTECH
Engg Pvt Ltd from July 2007 to till date.
2. Nature of work
• Testing and commissioning of all Electrical equipment from 415 volts to
765 KV System.
• Inspection of control and relay panel, preparation of Test Reports and
cable schedule for sub-station, power plant and process plant.
• Testing and commissioning of control & relay panel for
Transformer, Bus Coupler, Bus-Transfer and Line feeder.
• Testing of Protective Relays for various needs. Experience with over
current and earth fault relays.
• Also Knowledge in Transformer protection, Transformer Differential
Protection REF Protection, NGR Protection, Bus Bar protection,
Motor protection, Auto Reclosing Relay, LBB Protection,
Synchronizing scheme.
• Testing of CT, PT, CVT,Circuit breaker, switch gear and Power
Transformer,etc..
• Trouble shooting of all Electrical circuits,control and protection
circuits.
• Co-ordination with client in As Built Scheme drawing submission,
test report submission.
• As build cable schedule submission and all site activity to satisfy
the customer.
International Experience
1. Testing & commissioning of 380/13.8/4.16KV,480V Switchgear panel
Overall scheme checking, CT, PT, Circuit Breaker, Transformer testing,
protection relay testing and Cable schedule checking and preparation
as per drawing for 4000 MW QURAYYAH INDEPENDENT POWER
PLANT-KINGDOM OF SAUDI ARABIA, through SAMSUNG C&T.
2. Testing & commissioning of different Electrical equipments such as CT,
PT, Circuit Breaker, Protection Relay 11KV Switchgear control scheme
checking and its protective relays 64 TPD CEYLON OXYGEN PLANT,
COLOMBO, SRI LANKA.
India Experience
1. Testing & commissioning different Electrical equipments such as CT, PT,
Circuit Breaker, Isolator, Protection Relay 765/400/132/33KV Switchyard
overall control scheme checking and its protective relay at 3X 960 MW SASAN
ULTRA MEGA POWER PROJECT SINGRAULI, through M/s. TECHNO ELECTRIC
& ENGINEERING CO LTD.
2. Testing & commissioning of different Electrical equipments such as CT,PT,
Circuit Breaker, Isolator, Protection Relay 132 / 6.6KV Substation switchyard
control scheme checking and its protective relay for 2X75MW BLA POWER
PLANT GADARWARA, through AREVA T&D LTD.
1. Testing and Commissioning of 100 & 40 MVA Transformer with Control &
Protection Scheme checking, Testing of protective relays, Cable schedule
preparation for 220/132/33KV Substation UPPCL, DHONA, through
M/s. ABB Ltd.
3. 3. Testing & commissioning of different Electrical equipments such as CT,PT,
Circuit Breaker, Isolator, Protection Relay overall scheme checking, Cable
Schedule preparation and as-build drawing preparation for 220/132KV
Substation for MSETCL, KALLAM through M/s. TECHNO ELECTRIC &
ENGINEERING CO LTD.
4. Testing & commissioning of different Electrical equipments such as CT,PT,
Circuit Breaker, Isolator, Protection Relay overall scheme checking, Stability
check, cable schedule preparation, control scheme preparation for
220/66/11KV Substation for KPTCL, BANGALORE through M/S. VOLTECH
PROJECTS PVT LTD.
5. Testing & commissioning of different Electrical equipments such as CT, PT,
Circuit Breaker, Isolator, and overall Protection scheme checking for
400/220KV sub-station for M/s. Vedanta Aluminium Ltd, ORISA through
M/s.ABB Ltd.
6. Testing & commissioning of different Electrical equipments such as CT, PT,
Circuit Breaker, Isolator, overall scheme checking and as-build drawing
preparation for 220/132/33KV sub-station for Kota super thermal power
station, Rajasthan through M/S ABB Ltd.
7. Testing & commissioning of different Electrical equipments such as CT, PT,
Circuit Breaker, Isolator, overall scheme checking, Cable Schedule preparation
and as-build drawing preparation for 220/132KV Switchyard MSETCL,
BARANDA through M/s. TECHNO ELECTRIC & ENGINEERING CO LTD.
Executed the following Activities
• MICOM P632 Transformer differential protection relay checks
• know the Operates the CT Analyzer kit,CPC 100 kit,CMC 356 kit,
Meggar Kit
• Also know the operate the High voltage testing kit of PGK 50 and PGK80
• LBB & Busbar Protection checks
• Preparation of cable schedule & termination schedules
• Testing & Calibration of all meters
• CT, CVT & PT testing. Summation CT Test, Lighting Transformer test
• SF6 Gas Circuit Breaker Timing & Fail logic test
• Auxiliary relay & Backup Relay testing
• HT Cable & Panel Bus Bar HIPOT test
• Primary Injection up to relay end
• Transformer Sensitivity & REF Stability test
• DC scheme & Trip logic Checks
• Trip coil supervision circuit & Current measurement checks
• Auto reclose Scheme checks
Declaration
I hereby declare that all the information stated above is true knowledge
and belief.