The document provides installation and calibration instructions for an ED2-SM-Rona Series SkidWeigh system. It describes installing the pressure transducer and digital indicator, making electrical connections, and calibrating the system by lifting empty and known loaded weights. The calibration procedure zeroes the system when empty forks are lifted and sets the scale when a loaded weight is entered and lifted. It also describes setting an overload warning value.
The document provides instructions for installing, calibrating, testing, and using an ED2 Series SkidWeigh on-board check weighing system. It describes connecting the digital indicator and pressure transducer, selecting a mounting location for the indicator, and performing a quick test and full calibration by lifting empty and loaded forks. The user manual section outlines the standard weighing procedure of inserting forks into a load, lifting just above the ground, and reading the displayed weight.
The document provides installation and calibration instructions for the ED2-50 Series SkidWeigh check weighing system. It describes the components, installation of the pressure transducer and digital indicator, electrical connections, and calibration procedure. The calibration involves lifting empty and known loaded forks to automatically calibrate the weighing function to provide load weight readings within +/- 0.1 to 1% accuracy of the vehicle's maximum lifting capacity. Customer support is available via email or phone if additional assistance is needed with the installation and setup.
The document provides installation and calibration instructions for the ED2-SLL Series SkidWeigh load weighing system. It describes the key components, installation of the pressure transducer and digital indicator, electrical connections, and a two-step calibration process using empty and known loaded weights. The calibration establishes the system's load measurement in percentage of the vehicle's lifting capacity. For models with overload detection, it additionally walks through setting the overload warning value.
The document provides installation and calibration instructions for an ED2-30 Series SkidWeigh check weighing system. It describes how to install the digital indicator and pressure transducer, make electrical connections, and calibrate the system by lifting empty and loaded forks to automatically zero and set the scale. The document also describes the standard weighing procedure for operators and optional features for detecting excessive engine idling with visual warnings.
The document provides installation and calibration instructions for an ED2-RTLT Series SkidWeigh check weighing system. It describes:
1) Installing the digital indicator and pressure transducer, connecting the wiring harness between the two components.
2) Calibrating the system by lifting empty and known-weight loaded forks to automatically zero and set the scale.
3) Once calibrated, the operator lifts loads just above the ground to display the weight on the digital indicator.
The document provides installation and calibration instructions for an ED2-2X-SM Series SkidWeigh system. It describes installing the pressure transducer in the vehicle's hydraulic circuit and mounting the digital indicator. The calibration procedure involves lifting empty and known-weight loads to automatically calibrate the weighing function for load accuracy. Safety precautions and electrical connections are also outlined.
The document provides instructions for installing, calibrating, testing, and using an ED2-40 Series SkidWeigh system, an on-board check weighing unit for lift trucks, including connecting the pressure transducer and digital indicator, performing an electrical connections test, and calibrating the weighing function by lifting empty and loaded attachments above the ground. Safety precautions are outlined and installation should only be done by a qualified technician.
The document provides installation and calibration instructions for an ED2-EP Series SkidWeigh check weighing system. It describes installing the pressure transducer in the vehicle's lifting hydraulic circuit and mounting the digital indicator. The calibration procedure involves lifting empty and loaded forks to automatically zero the scale and set the load value. Proper electrical connections and a quick test are described to ensure correct installation before calibration.
The document provides instructions for installing, calibrating, testing, and using an ED2 Series SkidWeigh on-board check weighing system. It describes connecting the digital indicator and pressure transducer, selecting a mounting location for the indicator, and performing a quick test and full calibration by lifting empty and loaded forks. The user manual section outlines the standard weighing procedure of inserting forks into a load, lifting just above the ground, and reading the displayed weight.
The document provides installation and calibration instructions for the ED2-50 Series SkidWeigh check weighing system. It describes the components, installation of the pressure transducer and digital indicator, electrical connections, and calibration procedure. The calibration involves lifting empty and known loaded forks to automatically calibrate the weighing function to provide load weight readings within +/- 0.1 to 1% accuracy of the vehicle's maximum lifting capacity. Customer support is available via email or phone if additional assistance is needed with the installation and setup.
The document provides installation and calibration instructions for the ED2-SLL Series SkidWeigh load weighing system. It describes the key components, installation of the pressure transducer and digital indicator, electrical connections, and a two-step calibration process using empty and known loaded weights. The calibration establishes the system's load measurement in percentage of the vehicle's lifting capacity. For models with overload detection, it additionally walks through setting the overload warning value.
The document provides installation and calibration instructions for an ED2-30 Series SkidWeigh check weighing system. It describes how to install the digital indicator and pressure transducer, make electrical connections, and calibrate the system by lifting empty and loaded forks to automatically zero and set the scale. The document also describes the standard weighing procedure for operators and optional features for detecting excessive engine idling with visual warnings.
The document provides installation and calibration instructions for an ED2-RTLT Series SkidWeigh check weighing system. It describes:
1) Installing the digital indicator and pressure transducer, connecting the wiring harness between the two components.
2) Calibrating the system by lifting empty and known-weight loaded forks to automatically zero and set the scale.
3) Once calibrated, the operator lifts loads just above the ground to display the weight on the digital indicator.
The document provides installation and calibration instructions for an ED2-2X-SM Series SkidWeigh system. It describes installing the pressure transducer in the vehicle's hydraulic circuit and mounting the digital indicator. The calibration procedure involves lifting empty and known-weight loads to automatically calibrate the weighing function for load accuracy. Safety precautions and electrical connections are also outlined.
The document provides instructions for installing, calibrating, testing, and using an ED2-40 Series SkidWeigh system, an on-board check weighing unit for lift trucks, including connecting the pressure transducer and digital indicator, performing an electrical connections test, and calibrating the weighing function by lifting empty and loaded attachments above the ground. Safety precautions are outlined and installation should only be done by a qualified technician.
The document provides installation and calibration instructions for an ED2-EP Series SkidWeigh check weighing system. It describes installing the pressure transducer in the vehicle's lifting hydraulic circuit and mounting the digital indicator. The calibration procedure involves lifting empty and loaded forks to automatically zero the scale and set the load value. Proper electrical connections and a quick test are described to ensure correct installation before calibration.
Forklift weighing scales, ED2 at skid weigh installation manualTed Jurca
This document provides instructions for installing, calibrating, and using an ED2-AT Series SkidWeigh check weighing system. It describes the key components, installation process which includes mounting the pressure transducer and digital indicator, and electrical connections. It then explains the automatic two-point calibration procedure to zero the system and calibrate it using a known load weight. Optional settings for overload warnings are also described.
The document provides installation and calibration instructions for an ED2-AXO SkidWeigh system used for onboard check weighing of loads on shredder trucks. It describes connecting the digital indicator, pressure transducer, and wires and calibrating the system by lifting empty and known loads. The 3-sentence summary is:
The document outlines how to install an ED2-AXO SkidWeigh check weighing system on a shredder truck by connecting the digital indicator and pressure transducer, routing wires safely, and calibrating the system by lifting empty and test loads of 30-50% of maximum capacity to automatically set the zero point and load value. Proper use involves lowering loaded forks to initiate weighing and lifting to
Ed3 at v133 Lift truck onboard weighing scaleTed Jurca
This document provides installation and calibration instructions for the ED3-AT SkidWeigh Plus on-board check weighing system. It describes how to install the digital indicator, pressure transducer, and make electrical connections. It also explains how to enter the administration menu to calibrate the weighing function and set the date, time, and vehicle ID number. Safety precautions are provided regarding disconnecting batteries and securely mounting components.
Forklift weighing scale with overload warningTed Jurca
1) The document provides installation and calibration instructions for the SkidWeigh ED2-SM on-board lift truck scale system.
2) It describes how to install the pressure transducer and digital indicator, make electrical connections, perform a quick test of the system, and calibrate the system by lifting empty and loaded forks.
3) The calibration procedure involves zeroing the scale with empty forks, lifting a pre-weighed test load, and programming the known weight into the system using the paper clip and mode buttons.
This document provides instructions for installing and calibrating an ED2E-OL SkidWeigh system for weighing loads on lift trucks. The system consists of a digital indicator and hydraulic pressure transducer. Installation involves mounting the indicator and transducer, making electrical connections, and running transducer cables. Calibration is done by lifting empty forks to zero the system, then entering a known load weight lifted to set the scale. The system then displays load weight as a percentage of the vehicle's maximum capacity.
1) The document provides installation and calibration instructions for the SkidWeigh ED2-AT onboard check weighing scale system.
2) It describes how to install the pressure transducer and digital indicator, make electrical connections, perform a quick test of the system, and calibrate the system using both empty and loaded forks or attachments.
3) The calibration procedure involves zeroing the scale with empty forks, lifting a pre-weighed test load, and programming the known weight into the system using the paper clip and mode buttons.
The document provides installation and calibration instructions for an ED2-2X Series SkidWeigh check weighing system with two weighing channels. It describes the components, installation of the pressure transducer and digital indicator, electrical connections, and a calibration procedure to obtain load weight readings within 1% accuracy. Safety precautions are outlined and customer support contact information is provided.
Electric Pallet Truck Check Weighing System, ED2-EP V1200Ted Jurca
The document provides installation and calibration instructions for an ED2-EP electric pallet truck on-board weighing system. It describes the system components, installation of the pressure transducer and digital indicator, electrical connections, calibration procedures using empty and known loaded weights, and operating procedures for weighing loads. Safety precautions are outlined and two methods for automatically stopping lift motor travel during weighing are explained.
Electric Pallet Truck Weighing Scales, ED2 ep v1600Ted Jurca
The document provides installation and calibration instructions for an electric pallet truck on-board weighing system. It describes the system components, installation process which includes safety guidelines and connecting the pressure transducer and digital indicator. It explains the operational principal of measuring load weight based on hydraulic pressure. It provides details on calibrating the system by entering a known load weight value. The document aims to enable users to quickly install, calibrate and use the electric pallet truck weighing system.
This document provides installation and calibration instructions for an ED2E-Elite SkidWeigh onboard weighing scale system. It describes the key components, installation of the pressure transducer and digital indicator, electrical connections, and a calibration procedure to automatically zero the scale and calibrate it by lifting empty and known loaded forks above the ground. The calibration ensures accurate load weight measurement within 1% of the vehicle's maximum lifting capacity.
This document provides instructions for installing and calibrating an ED3-PC SkidWeigh Plus on-board check weighing system. It describes the main components, installation of the pressure transducer and digital indicator, making electrical connections, and performing tests and calibration. Safety precautions are outlined and installation should only be performed by a qualified technician. The system operates by measuring hydraulic pressure to determine load weight.
ScanWeight Systems from SkidWeigh TechnologyTed Jurca
This document provides installation, calibration, setup, and operation instructions for the ScanWeight V140 onboard check weighing system. Key steps include installing the pressure transducer and digital indicator, calibrating the system by lifting known weights, and configuring settings like date/time, vehicle ID, and operator access in the administration menu. Contact customer support is assistance is needed.
This 3 sentence summary provides the high level information from the installation and calibration manual:
The manual describes how to install, calibrate, test, and use the SkidWeigh ED2 on-board lift truck scale system. It outlines connecting the pressure transducer and digital indicator, performing a quick test, and calibrating the system through an automatic process of lifting empty and weighted forks. The calibration is completed in under 5 minutes and programs the system to accurately display weight readings.
This document provides instructions for installing, calibrating, testing, and using an onboard lift truck scale system. It describes the key components, how to install the pressure transducer, mount the digital indicator, make electrical connections, and perform a quick test and full calibration of the system using empty and loaded forks. Installation should only be performed by a trained lift truck technician and proper safety precautions must be followed.
The document provides installation and calibration instructions for a DURA-LIFT DL2-E onboard lift truck scale system. It describes:
1) Installing the pressure transducer in the lifting hydraulic line and digital indicator on the vehicle dashboard.
2) Calibrating the system by lifting empty forks to zero the scale, then lifting a known test weight to set the scale.
3) How to operate the system by lifting loads a few inches to display the weight on the indicator.
Load Capacity Weighing Scale for Lift Truck, Heavy Loads, Low liftTed Jurca
This document provides instructions for installing, calibrating, testing, and using an ICT-LCM-W load weighing scale system. The installation involves mounting a pressure transducer in the vehicle's hydraulic lifting circuit and a digital indicator. Connections are made between these components and the vehicle's electrical system. The calibration process involves lifting empty and loaded forks to program their weights into the system using the digital indicator's buttons.
The document provides installation and calibration instructions for an ED2-EP Series SkidWeigh on-board check weighing system. It describes installing the pressure transducer in the lifting hydraulic line and mounting the digital indicator. The calibration procedure involves lifting empty and loaded forks to automatically zero the scale and set the load value. Proper electrical connections and a quick test are described to ensure correct installation before calibration.
Cubefreight 500 for LTL freight transportation industrytedjurca
The CubeFreight 500 Series is a low-cost lift truck onboard device that automatically captures palletized freight weight, dimensions, and operational events. This information can optimize productivity, improve vehicle utilization and safety compliance with OSHA standards. The universal design works with any lift truck type or capacity and allows managers to determine freight costs in advance. The device will also benefit the LTL freight transportation industry by ensuring proper billing and more accurate trailer load planning. It features a compact design with a 5.7" touchscreen, integrated sensors to measure weight and dimensions, and captures standard load data.
The document provides installation and calibration instructions for the SkidFleet system. It describes how to install the pressure transducer and indicator unit, making proper electrical and hydraulic connections. It outlines safety procedures and gives guidelines for selecting mounting locations. The calibration process involves lifting empty and known-weight loads just above the ground to automatically set the zero point and calibration of the weighing system. Contact information is provided for technical support.
As the Volunteer Coordinator for the 2012 Ontario Colleges Marketing Competition hosted at Centennial College, the document discusses recruiting and managing 80 volunteers, up from 15 previously. Through an effective recruitment campaign and working with other faculty, the volunteer body was increased and the competition events were organized and run smoothly.
The document provides installation and calibration instructions for the ED3-PC & ED4-PC SkidWeigh Plus on-board check weighing systems. It describes how to install the pressure transducer and digital indicator, make electrical connections, do a quick test of the installation, and calibrate the system by lifting empty and loaded forks. It also explains how to set the date and time, test the pressure transducer, and use the piece counting and tare functions.
Forklift weighing scales, ED2 at skid weigh installation manualTed Jurca
This document provides instructions for installing, calibrating, and using an ED2-AT Series SkidWeigh check weighing system. It describes the key components, installation process which includes mounting the pressure transducer and digital indicator, and electrical connections. It then explains the automatic two-point calibration procedure to zero the system and calibrate it using a known load weight. Optional settings for overload warnings are also described.
The document provides installation and calibration instructions for an ED2-AXO SkidWeigh system used for onboard check weighing of loads on shredder trucks. It describes connecting the digital indicator, pressure transducer, and wires and calibrating the system by lifting empty and known loads. The 3-sentence summary is:
The document outlines how to install an ED2-AXO SkidWeigh check weighing system on a shredder truck by connecting the digital indicator and pressure transducer, routing wires safely, and calibrating the system by lifting empty and test loads of 30-50% of maximum capacity to automatically set the zero point and load value. Proper use involves lowering loaded forks to initiate weighing and lifting to
Ed3 at v133 Lift truck onboard weighing scaleTed Jurca
This document provides installation and calibration instructions for the ED3-AT SkidWeigh Plus on-board check weighing system. It describes how to install the digital indicator, pressure transducer, and make electrical connections. It also explains how to enter the administration menu to calibrate the weighing function and set the date, time, and vehicle ID number. Safety precautions are provided regarding disconnecting batteries and securely mounting components.
Forklift weighing scale with overload warningTed Jurca
1) The document provides installation and calibration instructions for the SkidWeigh ED2-SM on-board lift truck scale system.
2) It describes how to install the pressure transducer and digital indicator, make electrical connections, perform a quick test of the system, and calibrate the system by lifting empty and loaded forks.
3) The calibration procedure involves zeroing the scale with empty forks, lifting a pre-weighed test load, and programming the known weight into the system using the paper clip and mode buttons.
This document provides instructions for installing and calibrating an ED2E-OL SkidWeigh system for weighing loads on lift trucks. The system consists of a digital indicator and hydraulic pressure transducer. Installation involves mounting the indicator and transducer, making electrical connections, and running transducer cables. Calibration is done by lifting empty forks to zero the system, then entering a known load weight lifted to set the scale. The system then displays load weight as a percentage of the vehicle's maximum capacity.
1) The document provides installation and calibration instructions for the SkidWeigh ED2-AT onboard check weighing scale system.
2) It describes how to install the pressure transducer and digital indicator, make electrical connections, perform a quick test of the system, and calibrate the system using both empty and loaded forks or attachments.
3) The calibration procedure involves zeroing the scale with empty forks, lifting a pre-weighed test load, and programming the known weight into the system using the paper clip and mode buttons.
The document provides installation and calibration instructions for an ED2-2X Series SkidWeigh check weighing system with two weighing channels. It describes the components, installation of the pressure transducer and digital indicator, electrical connections, and a calibration procedure to obtain load weight readings within 1% accuracy. Safety precautions are outlined and customer support contact information is provided.
Electric Pallet Truck Check Weighing System, ED2-EP V1200Ted Jurca
The document provides installation and calibration instructions for an ED2-EP electric pallet truck on-board weighing system. It describes the system components, installation of the pressure transducer and digital indicator, electrical connections, calibration procedures using empty and known loaded weights, and operating procedures for weighing loads. Safety precautions are outlined and two methods for automatically stopping lift motor travel during weighing are explained.
Electric Pallet Truck Weighing Scales, ED2 ep v1600Ted Jurca
The document provides installation and calibration instructions for an electric pallet truck on-board weighing system. It describes the system components, installation process which includes safety guidelines and connecting the pressure transducer and digital indicator. It explains the operational principal of measuring load weight based on hydraulic pressure. It provides details on calibrating the system by entering a known load weight value. The document aims to enable users to quickly install, calibrate and use the electric pallet truck weighing system.
This document provides installation and calibration instructions for an ED2E-Elite SkidWeigh onboard weighing scale system. It describes the key components, installation of the pressure transducer and digital indicator, electrical connections, and a calibration procedure to automatically zero the scale and calibrate it by lifting empty and known loaded forks above the ground. The calibration ensures accurate load weight measurement within 1% of the vehicle's maximum lifting capacity.
This document provides instructions for installing and calibrating an ED3-PC SkidWeigh Plus on-board check weighing system. It describes the main components, installation of the pressure transducer and digital indicator, making electrical connections, and performing tests and calibration. Safety precautions are outlined and installation should only be performed by a qualified technician. The system operates by measuring hydraulic pressure to determine load weight.
ScanWeight Systems from SkidWeigh TechnologyTed Jurca
This document provides installation, calibration, setup, and operation instructions for the ScanWeight V140 onboard check weighing system. Key steps include installing the pressure transducer and digital indicator, calibrating the system by lifting known weights, and configuring settings like date/time, vehicle ID, and operator access in the administration menu. Contact customer support is assistance is needed.
This 3 sentence summary provides the high level information from the installation and calibration manual:
The manual describes how to install, calibrate, test, and use the SkidWeigh ED2 on-board lift truck scale system. It outlines connecting the pressure transducer and digital indicator, performing a quick test, and calibrating the system through an automatic process of lifting empty and weighted forks. The calibration is completed in under 5 minutes and programs the system to accurately display weight readings.
This document provides instructions for installing, calibrating, testing, and using an onboard lift truck scale system. It describes the key components, how to install the pressure transducer, mount the digital indicator, make electrical connections, and perform a quick test and full calibration of the system using empty and loaded forks. Installation should only be performed by a trained lift truck technician and proper safety precautions must be followed.
The document provides installation and calibration instructions for a DURA-LIFT DL2-E onboard lift truck scale system. It describes:
1) Installing the pressure transducer in the lifting hydraulic line and digital indicator on the vehicle dashboard.
2) Calibrating the system by lifting empty forks to zero the scale, then lifting a known test weight to set the scale.
3) How to operate the system by lifting loads a few inches to display the weight on the indicator.
Load Capacity Weighing Scale for Lift Truck, Heavy Loads, Low liftTed Jurca
This document provides instructions for installing, calibrating, testing, and using an ICT-LCM-W load weighing scale system. The installation involves mounting a pressure transducer in the vehicle's hydraulic lifting circuit and a digital indicator. Connections are made between these components and the vehicle's electrical system. The calibration process involves lifting empty and loaded forks to program their weights into the system using the digital indicator's buttons.
The document provides installation and calibration instructions for an ED2-EP Series SkidWeigh on-board check weighing system. It describes installing the pressure transducer in the lifting hydraulic line and mounting the digital indicator. The calibration procedure involves lifting empty and loaded forks to automatically zero the scale and set the load value. Proper electrical connections and a quick test are described to ensure correct installation before calibration.
Cubefreight 500 for LTL freight transportation industrytedjurca
The CubeFreight 500 Series is a low-cost lift truck onboard device that automatically captures palletized freight weight, dimensions, and operational events. This information can optimize productivity, improve vehicle utilization and safety compliance with OSHA standards. The universal design works with any lift truck type or capacity and allows managers to determine freight costs in advance. The device will also benefit the LTL freight transportation industry by ensuring proper billing and more accurate trailer load planning. It features a compact design with a 5.7" touchscreen, integrated sensors to measure weight and dimensions, and captures standard load data.
The document provides installation and calibration instructions for the SkidFleet system. It describes how to install the pressure transducer and indicator unit, making proper electrical and hydraulic connections. It outlines safety procedures and gives guidelines for selecting mounting locations. The calibration process involves lifting empty and known-weight loads just above the ground to automatically set the zero point and calibration of the weighing system. Contact information is provided for technical support.
As the Volunteer Coordinator for the 2012 Ontario Colleges Marketing Competition hosted at Centennial College, the document discusses recruiting and managing 80 volunteers, up from 15 previously. Through an effective recruitment campaign and working with other faculty, the volunteer body was increased and the competition events were organized and run smoothly.
The document provides installation and calibration instructions for the ED3-PC & ED4-PC SkidWeigh Plus on-board check weighing systems. It describes how to install the pressure transducer and digital indicator, make electrical connections, do a quick test of the installation, and calibrate the system by lifting empty and loaded forks. It also explains how to set the date and time, test the pressure transducer, and use the piece counting and tare functions.
Cube freight 600, lift truck onboard weighing and dimensioning systems by IVDTtedjurca
The CubeFreight 600 Series is a lift truck on-board system that automatically captures palletized freight weight, dimensions, and operational events. This helps optimize productivity, improve vehicle utilization and safety compliance. The universal system works on any lift truck type or capacity and allows managers to determine freight costs in advance. The system will also benefit the LTL freight transportation industry by ensuring proper billing and more accurate trailer load planning. The compact device measures between 12-254 inches, weighs less than 1 kg, and has a 5.7 inch touchscreen for real-time visibility of freight data.
EDI 5 Lift truck impact detection, monitoring systemstedjurca
The document discusses lift truck impact monitoring systems that can help manage impacts, reduce damage costs, and improve safety. The EDI-5 series impact monitor can detect and report on low and high impacts, and has options to integrate weighing scales, overload warnings, and real-time impact reporting. Case studies show how impact monitoring can reduce impacts over time by creating accountability and best practices for operators.
This submission outlines a direct marketing campaign conducted by students at St. Lawrence College for a real client--Blueprint Clothing Boutique in Kingston, Ontario.
Forklift onboard weighing scales,ED2 2 x installation & calibrationTed Jurca
This document provides instructions for installing, calibrating, testing, and using an ED2-2X Series SkidWeigh on-board check weighing system with two independent weighing channels. The system installation involves mounting a pressure transducer in the lifting hydraulic line and a digital indicator. Electrical connections are made and a quick test is performed to ensure proper installation. Weighing function calibration is then done by lifting empty and known load weights just above the ground. Standard operating procedures are outlined for weighing loads on each channel by lifting with the forks engaged.
The document provides installation instructions for an ED3 SkidWeigh Plus on-board check weighing system. It describes connecting the system components, which include a digital indicator and hydraulic pressure transducer. It outlines installing the pressure transducer in the lifting hydraulic line and connecting the indicator and transducer wires. It also describes how to select a mounting location for the indicator and perform a quick test of the electrical connections before calibrating the weighing function.
Ed3 & ed4 sm installation & calibration v101tedjurca
This document provides instructions for installing and calibrating the ED3 & ED4-SM SkidWeigh Plus on-board check weighing system. It describes the main components, safety procedures, and step-by-step instructions for installing the pressure transducer and digital indicator. It also provides guidance on connecting the electrical wires and performing a quick test to ensure proper installation before calibrating the weighing function.
Ed3 & ed4 sm installation & calibration v101tedjurca
The document provides installation and calibration instructions for the ED3 & ED4-SM SkidWeigh Plus on-board check weighing system. It describes how to install the pressure transducer and digital indicator, make electrical connections, perform a quick test, calibrate the system by lifting empty and loaded forks, and set up an overload warning. The system weighs loads by measuring hydraulic pressure when forks are lifted and provides the operator with load weight readings.
This document provides instructions for installing and calibrating an ED2-OL SkidWeigh system, which is an on-lift truck load weighing system. It describes installing the digital indicator and pressure transducer, making electrical connections, selecting a mounting location for the indicator, and performing a two-step calibration using empty and known loaded weights to automatically zero and calibrate the system. Safety precautions and an overview of system components are also provided.
This document provides instructions for installing and calibrating an ED2-OL SkidWeigh system, which is an on-lift truck load weighing system. It describes installing the digital indicator and pressure transducer, making electrical connections, selecting a mounting location for the indicator, and performing a two-step calibration using empty and known loaded weights. Safety precautions and an overview of system components are also provided.
Ed3 & ed4 at installation & calibration v!)!tedjurca
The document provides installation and calibration instructions for the ED3 & ED4-AT SkidWeigh Plus on-board check weighing system. It describes the main components, installation of the pressure transducer and digital indicator, electrical connections, safety precautions, and how to perform the automatic calibration by lifting empty and loaded forks. The calibration involves lowering empty forks, storing the empty reading, then lifting a load of known weight, entering the weight, and storing the loaded reading to calibrate the system.
The document provides installation and calibration instructions for the SkidWeigh ED2-AT onboard lift truck scale system, including installing the pressure transducer, mounting the digital indicator, making electrical connections, performing a quick test, calibrating the empty and loaded scales, and setting an optional overload warning value. Operational instructions are also given for using the scale system to weigh loads and accumulate a total weight.
This document provides installation and calibration instructions for an electric pallet truck onboard weighing system. It describes:
1) The components of the system and how to install the pressure transducer and mount the digital indicator.
2) How to calibrate the system by lifting empty and loaded forks to automatically set the zero point and load measurements.
3) The operator procedure for weighing loads which involves lifting loaded forks until weight is displayed.
The document provides installation and usage instructions for the SC3 SkidWeigh Classic lift truck onboard check weighing scale. It describes installing the pressure transducer and digital indicator, calibrating the system by lifting empty forks and forks with a known weight load, and operating the two weighing channels to display accumulated load weights. Safety precautions are outlined and technical support contact information is provided.
Similar to Ed2 sm-rona installation & calibration instructions (10)
Cube freight 400 lift truck dimensioning and palletized freight weighingtedjurca
The CubeFreight 400 Series is a low-cost lift truck onboard system that automatically captures palletized freight weight, dimensions, and operational events. This information can optimize productivity, improve vehicle utilization and safety compliance with OSHA standards. The universal system works with any lift truck type or capacity, and allows managers to determine freight costs in advance. The system will benefit the LTL freight transportation industry by ensuring proper billing and more accurate trailer load planning. The compact device measures between 12-254 inches to determine pallet height and provides a printed ticket with weight, size, and other standard data details.
Cube freight 300, LTL loading dock freight weight verification and dimensioningtedjurca
The CubeFreight 300 Series is a low-cost lift truck onboard system that automatically captures palletized freight weight, dimensions, and operational events. It determines freight costs in advance and ensures proper billing. The system benefits the LTL freight industry by allowing for more accurate trailer load planning. It weighs loads up to 5000 kg, measures pallet heights from 12-254 inches, and records operator and vehicle IDs, dates, weights, dimensions, and accumulated totals on a 5.7-inch touchscreen display.
Cube freight 200, forklift freight weight DIM systemstedjurca
The CubeFreight 200 Series is a lift truck on-board system that automatically captures palletized freight weight, dimensions, and operational events. It provides low-cost optimization of productivity, vehicle utilization, and safety compliance. The universal system works on any lift truck type or capacity and allows managers to determine freight costs in advance. The solution benefits the LTL freight transportation industry by ensuring proper billing and more accurate trailer loading planning. The compact system features a touch screen display, integrated scale, and printer for capturing freight data including weight, pallet size, and timestamps.
The CubeFreight 100 Series is a low-cost lift truck onboard system that automatically captures palletized freight weight, dimensions, and operational events. It determines freight costs in advance and ensures proper billing. The system benefits the LTL freight industry by allowing for more accurate trailer load planning. The universal device works on any lift truck type or voltage and provides weight, dimensions, operator ID, and other standard data on a 5.7-inch touchscreen display.
This document describes the EDI Defender Series product for managing impacts from lift trucks. The Defender uses a pressure transducer and microcontroller to measure and record impact forces of up to 16G. It has configurable impact warning levels and records impact events. The Defender can also function as a lift truck weighing scale to measure load weights with graduations from 1 to 100 pounds/kilograms. It has an impact resistant ABS enclosure and is rated for harsh industrial environments.
This document describes the ED3 SkidWeigh Plus series, which is a lift truck weighing and utilization monitoring system. It collects real-time data on lift trucks such as load weight, driving loaded/unloaded, and idle time to measure and improve utilization. Standard features include onboard weighing up to 50,000 pounds, load counting, and utilization tracking. Optional features allow for total load weighing, impact detection, overload warnings, and wireless reporting. The system is compact at 0.5kg and designed for rugged industrial use on material handling vehicles.
The document provides instructions for installing and calibrating the SkidFleet on-board check weighing system. It describes the main components, installation of the pressure transducer, and electrical connections. The calibration procedure involves lifting empty and known-weight loaded attachments to automatically set the zero point and scale. Contact customer support or the manufacturer for additional assistance during installation or calibration.
The document describes the SkidLevel 20, a wireless digital LED forks level indicator for telehandlers. It has a indicator that mounts in the vehicle cab and a forks level module. It requires no tools, wiring, or mechanical work and uses two D batteries that last about a year. Installation takes 30 seconds and calibration takes 10 seconds with the press of a button. It provides visual indications of battery life, replacement, and calibration mode.
EDI- 3 Installation for lift truck impact detection & reportingtedjurca
This document provides installation and operation instructions for the EDI-3 Defender Series lift truck impact detection system. It describes how to install the system, set low and high impact values, and use the on-board monitoring. The system consists of a digital indicator, wiring harness and mounting bracket. It detects and displays impact levels in G-forces and can be calibrated by the user. High impacts are recorded and can trigger alarms or notifications.
The EDI Defender Series provides lift truck impact detection and monitoring systems that integrate with fleet management systems. It monitors operator driving efficiency and productivity by reporting all impact events in real-time. Once installed, operational managers see immediate return on investment through improvements in operator behavior and reduced damage costs. The compact EDI-3 model has a heavy duty ABS enclosure that is water and dust tight, along with a high contrast LCD display and universal power supply input. It detects and reports on low and high impact events to help manage impacts and reduce costs.
The document discusses lift truck impact monitoring systems that can help manage impacts, protect equipment and ensure safety. It describes the EDI-5 Series Defender impact monitor, which detects and reports on low and high impacts. It attaches to lift trucks, measures impacts from 0.2 to 8 Gs, and can include add-ons like check weighing scales, overload warnings, and cellular reporting of high impact events. Case studies show how monitoring impacts over time can reduce damage costs and improve operator behavior.
The ED2 SkidWeigh Series is a compact, heavy duty, fully automatic system that measures load weight and operational data on material handling vehicles in real-time. It increases lift truck utilization by monitoring real-time vehicle usage, such as driving loaded/unloaded and lift time. Installation on a single vehicle allows operators to receive immediate feedback on underutilization. Standard specifications include a voltage range of 12-55V DC, IP67 rating, and accuracy of 0.1-1% of lifting capacity.
The ED3 SkidWeigh Plus Series is a compact digital indicator that provides on-board check weighing, lift truck utilization tracking, overload warning, and impact detection for lift trucks. It has standard features like multiple weighing channels, English/French display, and USB/RS232 ports. Optional features include total load weight tracking, underutilization monitoring, impact detection, and wireless reporting. The device is designed for material handling vehicles with a compact and durable ABS enclosure that provides NEMA 4X protection.
1. Installation & Calibration
ED2-SM-Rona Series SkidWeigh System
Lift Truck On-board Check Weighing With Overload Warning
ED2-SM-Rona Series SkidWeigh V.1.1
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7
2. General Installation Guide
This ED2-SM-Rona Series SkidWeigh system installation & calibration guide describes how to install, calibrate, test
and use your on-board check weighing unit. Following the instructions in this guide will enable you to get your system
operating quickly and easily. In the event that you require additional assistance, please contact customer support via e-
mail at support@skidweigh.com or visit www.skidweigh.com or contact us at the address or contact number below:
Integrated Visual Data Technology Inc.
3439 Whilabout Terrace, Oakville, ON, Canada, L6L 0A7
Phone: 905-469-0985, Fax: 905-825-9494
Safety
Always disconnect the vehicle battery while installing SkidWeigh system or any other electronic product.
Make sure sure that unit, pressure transducer and any other associated cables are securely mounted and do not impede
any of the vehicle’s controls. Use care when routing the components cables. Route the cables where they will be
protected. Use commonly accepted install practices for after market industrial vehicle electronic devices.
The installation of the SkidWeigh systems should only be performed by an acknowledged lift truck dealer technician or
end user electro and hydraulic technical installer.
Here are two acceptable methods of making a wire connections:
* Soldering your connections (recommended)
* Crimp connectors ( with the use of the proper crimping tool)
Regardless of the method you choose, ensure that the connection is mechanically sound and properly insulated. Use
high quality electrical tape and shrink tubing where necessary.
This product is connected directly to the vehicle’s ignition switch, 12 to 55 V DC. There is no on-off switch on the unit.
Electro-Magnetic Compatibility
CE conformity to EC directive 89/336 (EMC) by application of harmonized standards: Interference stability EN 61000-6-2
and EN 61326-1 interference emit EN 61000-6-3, EN 61326-1 for the pressure transducer.
ED2 SkidWeigh Series
Our policy is one of continuous improvement and the information in this document is subject to change without notice.
Check that software version displayed on LED is the one applicable for your application.
Overview of components
The standard ED2-SM-Rona SkidWeigh check weighing system consist of two main components:
* Digital indicator with wiring harness, mounting bracket and anti-vibration mount
* Hydraulic pressure transducer with 3 wires cable
* Installation & Calibration manual and operator usage instruction
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7
3. Operational principal
The ED2-SM-Rona Series SkidWeigh system operational principal is based on the hydraulic pressure transducer
mounted in the vehicle lifting hydraulic circuit that will automatically activate the “weighing cycle / specific algorithm ”
every time a skid load is lifted just above the ground. The increase in pressure is converted in an electronic signal at the
sample rate of 16000 readings which is converted into a load weight reading.
Pressure transducer installation
The pressure transducer must be installed in the lifting hydraulic line between the lift control valve and lift
cylinder(s). Mount a T-piece in lifting hydraulic line. In some cases you can install the pressure transducer in the flow
divider, drilling and tapping for 1/4”-18 NPT male in spare plug (if only single or double mast configuration) or in the body
of the flow divider. Also, you can drill and tap on any “larger elbow” that might be available in the hydraulic lifting circuit
found in vehicles with larger hoses to accommodate larger vehicle lifting capacities.
Pressure transducer installation precautions
Before installation of the pressure transducer the hydraulic lift circuit must be pressure free.
There are two ways to do that:
1. Place the forks on the ground in their lowest position and make the hydraulic system pressure free by tilting the mast
forward. The chain(s) should be slack.
2. Lift the forks and position them on the top of a supporting fixture. Start lowering the lifting cylinder into its lowest
position. Be sure that chain(s) are slack.
Make sure that that installed pressure transducer will not touch any moving parts or assembly of the vehicle while in
normal operation. Pressure transducer has 1/4”-18 NPT male thread. Use thread seal to ensure tight fit.
Selecting the mounting location for digital indicator
Use the mounting bracket with the anti vibration mount and fasten digital indicator on the vehicle dashboard or side
railing preferably on the right hand side. There are many examples of mounting locations that will depend on the vehicle
model. However, additional mounting items such as a flat brackets may be needed to help secure the unit to upper right
corner of the guard or side railing.
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7
4. Choose the correct location and make sure that:
- Indicator is visible and within reach of the operator
- Location so that operator does not hit a head
Compact size
All of the SkidWeigh systems are compact size, housing dimension
of only 120 x 80 x 55 mm.
Electrical Connections
All SkidWeigh systems operate from 12 to 55 V DC.
Digital indicator with seven wires single cable
- Orange Wire (+) Ignition switch On position
- Brown Wire (-) Battery negative
- Red Wire, connect to RED wire of the pressure transducer cable
- Black Wire, connect to BLACK wire of the pressure transducer cable
- White Wire, connect to WHITE wire of the pressure transducer cable
Pressure transducer cable
Pressure transducer cable must be connected to the digital indicator seven wires single cable
- White Wire, signal 0 to 2,5 V
- Black Wire, signal negative
- Red Wire, power supply to pressure transducer + 11 V DC
Electrical power short circuit protection
- All of the SkidWeigh systems are internally short circuit protected with resettable fuse. There is no need to install
external inline fuse in orange wire connected to the ignition switch.
- Automotive 60 V load dump protection
- Reversal power supply protection
- Note: Any external devices connected to the SkidWeigh system, such as non standard onboard printer might require
external fuse.
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7
5. “Quick test to determine if electrical connections are done right”
Note: SkidWeigh weighing calibration function is not done
yet at this stage. This procedure is only to test if electrical
connections of the system installation into the vehicle is
done properly!
After you have connected electrical power and pressure
transducer cable you can “quickly” check the system
operation. - Lower the forks to the ground
- Turn On ignition switch
- Digital LED display will be activated, showing software
version and serial number
- Number 8 will be shown on LED display above the Mode
sign.
-Go ahead and lift the forks and engaged second mast to
increase pressure in lifting cylinder. Number 8 will go off and some load weight will be shown on LED display.
If the above test is valid than the system electrical connections are done right. The next procedure will be to calibrate
the SkidWeigh weighing function.
Lift truck equipped with hydraulic accumulator
If the standard SkidWeigh system is installed on the lift trucks equipped with hydraulic accumulators, please contact us
to provide you with different digital indicator having specific software algorithm to obtain load weight accuracy within +/-
0.1 to 1% of vehicle maximum lifting capacity.
Weighing function calibration procedure
The ED2-SM-Rona Series SkidWeigh calibration is automatic and is done by lifting empty and loaded forks (or any
other attachment such as paper clamp) just above the ground. MAKE SURE THAT YOU HAVE A KNOWN LOAD
WEIGHT AND KEEP IT NEARBY TO COMPLETE THE CALIBRATION.
For the best results use at least minimum calibration load test weight of 30 to 50% of maximum lifting capacity of the lift
truck. Use customer floor scale or find a known skid load weight within the operational facility.
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7
6. Important: If you want the system to show load weight in pounds, use the known load weight in pounds and
enter that value accordingly. The same would apply if you want the system to show load weight in kilograms.
Use the known load weight in kilograms and enter that value into the system accordingly.
Digital Indicator (Calibration and two keys description)
- Upper right button “M” is used to enter calibration mode and to shift left to the next digit.
- Lower right button “Arrow Up” is used to enter numerical increments from 1-9, wrap around.
- Both buttons are used during the system calibration.
- Buttons can be accessed through two small holes on the cover.
- Use paper clip to activate buttons. Do not push buttons too hard!
- Left most significant digit represents Mode of operation.
- Other five digits represent the load weight readout.
Mode LED Digit Five Digits Load Weight Display
MODE Digit 5 Digit 4 Digit 3 Digit 2 Digit 1
- Note:
- Every time the power is applied the software version will be shown momentarily for a brief moment.
- When forks are lowered to ground LED display will show Mode 8. This is a starting point to take load weights.
- For best results during weight calibration use at least 30 to 50 % of known lad weight of the vehicle lifting capacity.
- If you make a mistake during the system calibration, turn power ON / OFF and start all over.
- If the power to the system is disconnected calibration information / set up information will not be lost.
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7
7. Calibration Starting Point For All Of The ED2 Series SkidWeigh Systems
---------------------------------------------------------------------------------------
Lower the empty forks to the ground. There should be no hydraulic pressure in lift hydraulic circuit.
- Turn ignition switch to on position (electric lift trucks) and start the engine on combustion powered lift trucks
- LED display will show software version briefly on the right side and number 8 will be shown in the Mode digit.
---------------------------------------------------------------------------------------
1. Calibration of empty forks lifted just above the ground
To initiate calibration press the “M” key (use a paper clip) and hold it down for approx. 5 seconds.
After 5 seconds the Mode display digit will change from number 8 to 0.
System is ready for automatic zeroing of the scale function
When LED display is showing “0” in Mode digit, lift the empty forks ( or attachment such as longer forks, clamp, etc)
just above the ground.
Note: Activate the lift control valve as you would do during the normal lifting operation. Do not lift the empty forks slowly.
Wait few seconds, LED display will go blank and will show Mode digit 1 and default “0” value in furthest right digit
display.
(The “0” value in furthest right digit might be some other number if calibration done previously with different load weight)
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7
8. Automatic zeroing is done !
2. Calibration of loaded forks lifted just above the ground
At this point drive your vehicle into the skid load with known weight and lower the loaded forks to the ground.
(In this example the known load weight is 4000 kg)
- Start entering a known load weight into digital indicator by using arrow up button (increments from 0 to 9) with wrap
around function. Start with least significant digit of your known load weight.
- Use the “M” button to increment to next digit on the LED display.
First least Second least Third least Forth least Must enter “0”
significant digit “0” significant digit “0” significant digit “0” significant digit “4”
- Repeat this procedure until the Mode digit display is showing number 4.
Caution: In our example a known load weight value of 4000 kg consist only of four digits. Make sure that
the 5th digit has “0” value entered into the calibration system. ( 504000)
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7
9. - With forks on the ground press “M” button to advance to Mode “6” and lift loaded forks just above the ground.
Within few seconds display will show the value of the known load weight.
Overload Warning Input Value Procedure (ED2-SM-Rona)
• In order to input the overload value into the system you must lower the loaded forks to the ground.
• The Mode number 8 will automatically advance to the Mode 7.
Using the “M” and “Up Arrow” keys enter the overload weight value for your application. The Mode 7 digit remains
throughout this operation. On the last shift utilizing “M” key the Mode 7 digit will turn off. The overload weight value will
be successfully stored in the system memory.
• Note: If the overload input value is as of the example 4850, having only 4 digits make sure that 5th digit is 0.
Mode Digit 5 Digit 4 Digit 3 Digit 2 Digit 1
7 0 4 8 5 0
ED2-SM-Rona Series SkidWeigh Systems
Weight Calibration And Overload Warning Function Is Done
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7
10. User’s Manual
Lift truck operator copy
Standard Weighing Procedure (All ED2-SM-Rona Series SkidWeigh & FreightWeigh systems)
• Insert the forks into the pallet load. Lower the forks to the ground. With no hydraulic pressure in lifting line
the Mode LED display will show number 8.
System is ready to weigh product on the forks.
• Activate the lift control lever and lift the load just above the ground.
• As soon as the load is lifted, digital display will go “blank” for a moment and the load weight will be shown
on the LED display.
Note: To initiate the “Weighing Cycle” the LED indicator must show Mode 8. If LED display shows any
other number, lower the forks to the ground. Always activate lift control valve lever “quickly” and lift the load
weight just above the ground. Do not attempt to lift the load slowly!
Check weighing accuracy is within +/- 0.1 to 1% of lift truck maximum lifting capacity.
• Overload Warning: Every time the pre-set overload load weight is lifted the LED display will show the load
weight value. All digits will “FLASH”. Buzzer will be activated as well if the system equipped with audio
warning. To stop LED display “FLASHING” and to turn buzzer off, lower the overloaded weight to ground.
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7