Double Beam UV-Vis Spectrophotometer LUS-B10 is a compact, table top double beam designed UV-Vis spectrophotometer comprising Silicon photodiode detector, Tungsten and Deuterium lamp as light source.
Atomic absorption spectrophotometer comes with Deuterium lamp for background correction, RS232 interface, Multi-linear and nonlinear curve fitting.
Its double beam system automatically compensates the light source drift and wavelength drift caused by the variation of temperature and electronic
circuit drift so as to reach a good basic line stability.
Visible spectrophotometer offers 330 to 1000 nm wavelength range with single beam has 1200 lines/mm grating C-T monochromator
optical system. It uses silicon photo diode detector and tungsten lamp as light source which provides the best wavelength
coverage across the working range of the spectrophotometer. The Display screen show the concentration data. This highly
accurate spectrophotometer is designed for industries and laboratories.
Its a Powerful tool for measuring the absorbance of enzymatic reactions in a microplate. Our ELISA Reader is designed to provide efficient and accurate results, making it ideal for various applications in clinical diagnostics.
It offers high throughput with 3 shaking modes, fast reading speed of 5 seconds and
malfunction alarm system along with 96-well multimode and bichromatic multi-channel
optical system. Different detection modes like comprehensive qualitative and quantitative
data-evaluation functions with cut-offs, curve-fits and transformation formulas are
available. It is a basic tool in drug detection and life science research, bioassay
testing and quality control pharmaceutical processes.
Looking for a reliable fluorescence spectrophotometer? Look no further than Labozon. Our advanced technology ensures precise measurements and easy operation for all your research needs.
Angstrom Advanced is the leading supplier for ellipsometers. We offer full range of ellipsometers for thin film thickness measurement and optical characterization for refractive index and extinction coefficient (n & k). The Angstrom Advanced ellipsometer family includes discrete wavelength ellipsometers (single wavelength ellipsometers and multi-wavelength ellipsometers), deep UV, UV, VIS, NIR and IR spectroscopic ellipsometers. Our ellipsometers have been delivered to many renowned universities, research institutes and companies worldwide. Angstrom Advanced's goal is to supply the most accurate and repeatable ellipsometers with the highest standard of customer satisfaction. Many upgrade accessories are available for different applications.
www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường. Chuyên cung cấp vật tư cho dự án xử lý nước sạch, nước thải và môi trường. Envimart luôn đồng hành, tin cậy với đối tác nhà thầu, nhà tích hợp và người sử dụng.
Atomic absorption spectrophotometer comes with Deuterium lamp for background correction, RS232 interface, Multi-linear and nonlinear curve fitting.
Its double beam system automatically compensates the light source drift and wavelength drift caused by the variation of temperature and electronic
circuit drift so as to reach a good basic line stability.
Visible spectrophotometer offers 330 to 1000 nm wavelength range with single beam has 1200 lines/mm grating C-T monochromator
optical system. It uses silicon photo diode detector and tungsten lamp as light source which provides the best wavelength
coverage across the working range of the spectrophotometer. The Display screen show the concentration data. This highly
accurate spectrophotometer is designed for industries and laboratories.
Its a Powerful tool for measuring the absorbance of enzymatic reactions in a microplate. Our ELISA Reader is designed to provide efficient and accurate results, making it ideal for various applications in clinical diagnostics.
It offers high throughput with 3 shaking modes, fast reading speed of 5 seconds and
malfunction alarm system along with 96-well multimode and bichromatic multi-channel
optical system. Different detection modes like comprehensive qualitative and quantitative
data-evaluation functions with cut-offs, curve-fits and transformation formulas are
available. It is a basic tool in drug detection and life science research, bioassay
testing and quality control pharmaceutical processes.
Looking for a reliable fluorescence spectrophotometer? Look no further than Labozon. Our advanced technology ensures precise measurements and easy operation for all your research needs.
Angstrom Advanced is the leading supplier for ellipsometers. We offer full range of ellipsometers for thin film thickness measurement and optical characterization for refractive index and extinction coefficient (n & k). The Angstrom Advanced ellipsometer family includes discrete wavelength ellipsometers (single wavelength ellipsometers and multi-wavelength ellipsometers), deep UV, UV, VIS, NIR and IR spectroscopic ellipsometers. Our ellipsometers have been delivered to many renowned universities, research institutes and companies worldwide. Angstrom Advanced's goal is to supply the most accurate and repeatable ellipsometers with the highest standard of customer satisfaction. Many upgrade accessories are available for different applications.
www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường. Chuyên cung cấp vật tư cho dự án xử lý nước sạch, nước thải và môi trường. Envimart luôn đồng hành, tin cậy với đối tác nhà thầu, nhà tích hợp và người sử dụng.
Nano spectrophotometer with full spectrum light covers wide wavelength range of 200 to 800nm. It requires only 0.5 - 2.0 µl micro-volume sample for
measurement which takes place within 5 seconds. It utilizes CCD detector, Xenon flash lamp as light source which has high stability and long operating life.
They are used to detect micro volume quantities of nucleic acids and other concentrated or dilute components.
Portable Turbidity Meter quickly determines the number of suspended particles in water. Microprocessor-based circuitry assures high precise and repeatable readings.
It uses an infrared light source and 90° scattering method, which is compliant with the ISO 7027 method. Portable design allows you to take measurement on-site
instead of bringing solution back to the laboratory. 200 sets of data are stored and can be transferred to PC by USB communication interface.
Portable turbidity meters are commonly used to assess the clarity and quality of water in natural bodies of water, drinking water sources, and water distribution systems. High turbidity levels can indicate the presence of contaminants, sediments, or pollutants in water. Researchers in various fields may use portable turbidity meters for experiments and studies related to colloidal chemistry, particle characterization, and the stability of suspensions.
Atomic absorption spectrophotometer comes with Deuterium lamp for background correction, RS232 interface, Multi-linear and nonlinear curve fitting.
Its double beam system automatically compensates the light source drift and wavelength drift caused by the variation of temperature and electronic
circuit drift so as to reach a good basic line stability. The specially designed fine light beam passes through the flame to ensure a high precision
analytical test and low characteristic concentration in this atomic absorption spectrophotometer. It has multiple applications in research and
development and industrial analysis.
Our Automatic Visible Spectrophotometer is especially designed for the use of the use of environmental protection and education. It is highly economical, reliable and easy to use. It is also widely useful in quantitative analysis or qualitative analysis in the fields of physics, chemistry, medicine, biology and pharmaceutical factory. For More Information Please Logon http://goo.gl/Zhgcah
Fluorometer is the next generation benchtop dual-channel fluorometers having excitation filters of 365 ± 20 nm and 460 ± 20 nm. It measures ds-DNA concentration with
great sensitivity and a lower DNA detection limit of 0.5 ng/µl. Designed to provide fluorescence in the UV and blue channels for accurate determination of sample
concentration.
Raman Spectrometer is a high throughput analytical instrument that combines phenomenon of microscopic imaging along with the spectrometer detection
for structural analysis of a compound. It possesses great sensitivity with features such as fully automatic focusing mechanism with enhanced CCD detector system.
Microplate reader consists of a silicon photodiode as a photodetector and an optical system with 8-channel optical fiber scanning. It can store 500 test items and 10,000,000 test data points and perform 12 different tests on just one plate. The system is equipped with a USB interface for easy connection to the PC. It works on a single or dual wavelength, gives qualitative and quantitative data evaluation, and also consists of an LED or tungsten halogen lamp as a light source.
The system mainly consists of a UV-VIS-IR spectroradiometer, a retina radiance meter for the measurement of spectral radiance, a light receiver for the measurement of sepctral radiance, a light receiver for the measurement of spectral irradiance, a motorized two-axis rotation goniometer for the measurement at 200mm and 500lx condition of general lighting sources, calibrated sources of spectral irradiance with the wavelength from 200nm to 3000nm and that of spectral radiance with the wavelength from 300nm to 1400nm.
JERICHO OPHTHALMIC MULTISPOT GREEN LASER SYSTEM-532NMGovindarajanR5
Appa Ophthalmic Multispot Green Laser Jericho is designed with effective touch screen interface providing superior surgical treatment to retinal problems.
NIR Spectrophotometer is a spectrophotometer with grating monochromator. The wavelength range is 900 nm to 2500 nm and temperature ranges from
5 to 35℃. Single channel whole spectrum scanning offers low dark noise and high sensitivity. It features built-in high-quality PTFE reference module
and polystyrene wavelength standard filter. It combines the data with the corresponding NIR data model, various components of the tested sample can be
obtained at the same time.
Colorimeter is a durable photoelectric colorimeter with benchtop design. Equipped with specific light filters of the visible range (420 to 660 nm) to measure
the concertation and determine the color. Its three digit LED display shows Transmittance and Absorbance values.
Introduction of SG-O CIS / ALS / Light-Sensor Wafer TesterEnlitech
Introduction of SG-O CIS / ALS / Light-Sensor Wafer Tester
Original link:https://enlitechnology.com/home/products/image-sensor/sg-o/
*About Enlitech
Enlitech was founded in March 2009.
The core technologies include artificial light source and spectrum analyzing technique.Enlitech’s four main product markets include image sensor testing solutions, advanced photoelectric detector testing systems, quantum efficiency test solutions, and various light simulators.
Our popular products are QER and SS-X solar simulator. If you are interested, please visit the official website to understand more!
https://enlitechnology.com/
Portable Chlorine Meter is small size designed and developed based on colorimetric method. Designed with LED light source and offers 515 nm wavelength of light.
More Related Content
Similar to Double Beam UV Vis Spectrophotometer.pdf
Nano spectrophotometer with full spectrum light covers wide wavelength range of 200 to 800nm. It requires only 0.5 - 2.0 µl micro-volume sample for
measurement which takes place within 5 seconds. It utilizes CCD detector, Xenon flash lamp as light source which has high stability and long operating life.
They are used to detect micro volume quantities of nucleic acids and other concentrated or dilute components.
Portable Turbidity Meter quickly determines the number of suspended particles in water. Microprocessor-based circuitry assures high precise and repeatable readings.
It uses an infrared light source and 90° scattering method, which is compliant with the ISO 7027 method. Portable design allows you to take measurement on-site
instead of bringing solution back to the laboratory. 200 sets of data are stored and can be transferred to PC by USB communication interface.
Portable turbidity meters are commonly used to assess the clarity and quality of water in natural bodies of water, drinking water sources, and water distribution systems. High turbidity levels can indicate the presence of contaminants, sediments, or pollutants in water. Researchers in various fields may use portable turbidity meters for experiments and studies related to colloidal chemistry, particle characterization, and the stability of suspensions.
Atomic absorption spectrophotometer comes with Deuterium lamp for background correction, RS232 interface, Multi-linear and nonlinear curve fitting.
Its double beam system automatically compensates the light source drift and wavelength drift caused by the variation of temperature and electronic
circuit drift so as to reach a good basic line stability. The specially designed fine light beam passes through the flame to ensure a high precision
analytical test and low characteristic concentration in this atomic absorption spectrophotometer. It has multiple applications in research and
development and industrial analysis.
Our Automatic Visible Spectrophotometer is especially designed for the use of the use of environmental protection and education. It is highly economical, reliable and easy to use. It is also widely useful in quantitative analysis or qualitative analysis in the fields of physics, chemistry, medicine, biology and pharmaceutical factory. For More Information Please Logon http://goo.gl/Zhgcah
Fluorometer is the next generation benchtop dual-channel fluorometers having excitation filters of 365 ± 20 nm and 460 ± 20 nm. It measures ds-DNA concentration with
great sensitivity and a lower DNA detection limit of 0.5 ng/µl. Designed to provide fluorescence in the UV and blue channels for accurate determination of sample
concentration.
Raman Spectrometer is a high throughput analytical instrument that combines phenomenon of microscopic imaging along with the spectrometer detection
for structural analysis of a compound. It possesses great sensitivity with features such as fully automatic focusing mechanism with enhanced CCD detector system.
Microplate reader consists of a silicon photodiode as a photodetector and an optical system with 8-channel optical fiber scanning. It can store 500 test items and 10,000,000 test data points and perform 12 different tests on just one plate. The system is equipped with a USB interface for easy connection to the PC. It works on a single or dual wavelength, gives qualitative and quantitative data evaluation, and also consists of an LED or tungsten halogen lamp as a light source.
The system mainly consists of a UV-VIS-IR spectroradiometer, a retina radiance meter for the measurement of spectral radiance, a light receiver for the measurement of sepctral radiance, a light receiver for the measurement of spectral irradiance, a motorized two-axis rotation goniometer for the measurement at 200mm and 500lx condition of general lighting sources, calibrated sources of spectral irradiance with the wavelength from 200nm to 3000nm and that of spectral radiance with the wavelength from 300nm to 1400nm.
JERICHO OPHTHALMIC MULTISPOT GREEN LASER SYSTEM-532NMGovindarajanR5
Appa Ophthalmic Multispot Green Laser Jericho is designed with effective touch screen interface providing superior surgical treatment to retinal problems.
NIR Spectrophotometer is a spectrophotometer with grating monochromator. The wavelength range is 900 nm to 2500 nm and temperature ranges from
5 to 35℃. Single channel whole spectrum scanning offers low dark noise and high sensitivity. It features built-in high-quality PTFE reference module
and polystyrene wavelength standard filter. It combines the data with the corresponding NIR data model, various components of the tested sample can be
obtained at the same time.
Colorimeter is a durable photoelectric colorimeter with benchtop design. Equipped with specific light filters of the visible range (420 to 660 nm) to measure
the concertation and determine the color. Its three digit LED display shows Transmittance and Absorbance values.
Introduction of SG-O CIS / ALS / Light-Sensor Wafer TesterEnlitech
Introduction of SG-O CIS / ALS / Light-Sensor Wafer Tester
Original link:https://enlitechnology.com/home/products/image-sensor/sg-o/
*About Enlitech
Enlitech was founded in March 2009.
The core technologies include artificial light source and spectrum analyzing technique.Enlitech’s four main product markets include image sensor testing solutions, advanced photoelectric detector testing systems, quantum efficiency test solutions, and various light simulators.
Our popular products are QER and SS-X solar simulator. If you are interested, please visit the official website to understand more!
https://enlitechnology.com/
Similar to Double Beam UV Vis Spectrophotometer.pdf (20)
Portable Chlorine Meter is small size designed and developed based on colorimetric method. Designed with LED light source and offers 515 nm wavelength of light.
Portable airborne particle counter is a six channel microcomputer controlled unit. It has a provision of simultaneously counting particles in six different size ranges with real time monitoring.
Platelet Incubator is a continuous side-to-side motion agitation incubator which operates at a temperature range of 4°C to 26°C with one agitation chamber.
Water absorption tester TP-C20 is used to measure the degree of water absorption of a paper & cloth. Designed using ‘Rise in capillary by millimetres' principle, where a specimen is suspended in a vat filled with water.
Softness tester TP-H10 is adopted with microprocessor controlled technology and liquid crystal display to view and observe test parameters and result values.
Lighting Incubator is a 2 side light illuminating incubator runs under microprocessor PID control system with lighting illumination of 0 to 12000 lx. Offers two types of temperature control range: with illumination 10 °C to 50 °C and without illumination 5 °C to 50 °C.
Laser Theodolite with built-in diode, the laser beam is visible up to 200 m away outside in daylight. A clear laser spot is visible up to 100 m through eyepiece.
Manifold Freeze Dryer is a compact table-top unit with 3 kg condenser capacity and condenser temperature of - 50 °C used for drying aqueous specimens.It allows larger glassware like flasks to be dried independent of the shelving units.
Gas Chromatography is a benchtop unit with advanced flow controller (AFC) technology. System has digital control mode and polar capillary columns to separate polar analytes.
Ducted Fume hood is a microprocessor controlled ducted fume hood with built in centrifugal blower which removes toxic gases to the outside of the working environment.
Seminar of U.V. Spectroscopy by SAMIR PANDASAMIR PANDA
Spectroscopy is a branch of science dealing the study of interaction of electromagnetic radiation with matter.
Ultraviolet-visible spectroscopy refers to absorption spectroscopy or reflect spectroscopy in the UV-VIS spectral region.
Ultraviolet-visible spectroscopy is an analytical method that can measure the amount of light received by the analyte.
Introduction:
RNA interference (RNAi) or Post-Transcriptional Gene Silencing (PTGS) is an important biological process for modulating eukaryotic gene expression.
It is highly conserved process of posttranscriptional gene silencing by which double stranded RNA (dsRNA) causes sequence-specific degradation of mRNA sequences.
dsRNA-induced gene silencing (RNAi) is reported in a wide range of eukaryotes ranging from worms, insects, mammals and plants.
This process mediates resistance to both endogenous parasitic and exogenous pathogenic nucleic acids, and regulates the expression of protein-coding genes.
What are small ncRNAs?
micro RNA (miRNA)
short interfering RNA (siRNA)
Properties of small non-coding RNA:
Involved in silencing mRNA transcripts.
Called “small” because they are usually only about 21-24 nucleotides long.
Synthesized by first cutting up longer precursor sequences (like the 61nt one that Lee discovered).
Silence an mRNA by base pairing with some sequence on the mRNA.
Discovery of siRNA?
The first small RNA:
In 1993 Rosalind Lee (Victor Ambros lab) was studying a non- coding gene in C. elegans, lin-4, that was involved in silencing of another gene, lin-14, at the appropriate time in the
development of the worm C. elegans.
Two small transcripts of lin-4 (22nt and 61nt) were found to be complementary to a sequence in the 3' UTR of lin-14.
Because lin-4 encoded no protein, she deduced that it must be these transcripts that are causing the silencing by RNA-RNA interactions.
Types of RNAi ( non coding RNA)
MiRNA
Length (23-25 nt)
Trans acting
Binds with target MRNA in mismatch
Translation inhibition
Si RNA
Length 21 nt.
Cis acting
Bind with target Mrna in perfect complementary sequence
Piwi-RNA
Length ; 25 to 36 nt.
Expressed in Germ Cells
Regulates trnasposomes activity
MECHANISM OF RNAI:
First the double-stranded RNA teams up with a protein complex named Dicer, which cuts the long RNA into short pieces.
Then another protein complex called RISC (RNA-induced silencing complex) discards one of the two RNA strands.
The RISC-docked, single-stranded RNA then pairs with the homologous mRNA and destroys it.
THE RISC COMPLEX:
RISC is large(>500kD) RNA multi- protein Binding complex which triggers MRNA degradation in response to MRNA
Unwinding of double stranded Si RNA by ATP independent Helicase
Active component of RISC is Ago proteins( ENDONUCLEASE) which cleave target MRNA.
DICER: endonuclease (RNase Family III)
Argonaute: Central Component of the RNA-Induced Silencing Complex (RISC)
One strand of the dsRNA produced by Dicer is retained in the RISC complex in association with Argonaute
ARGONAUTE PROTEIN :
1.PAZ(PIWI/Argonaute/ Zwille)- Recognition of target MRNA
2.PIWI (p-element induced wimpy Testis)- breaks Phosphodiester bond of mRNA.)RNAse H activity.
MiRNA:
The Double-stranded RNAs are naturally produced in eukaryotic cells during development, and they have a key role in regulating gene expression .
Slide 1: Title Slide
Extrachromosomal Inheritance
Slide 2: Introduction to Extrachromosomal Inheritance
Definition: Extrachromosomal inheritance refers to the transmission of genetic material that is not found within the nucleus.
Key Components: Involves genes located in mitochondria, chloroplasts, and plasmids.
Slide 3: Mitochondrial Inheritance
Mitochondria: Organelles responsible for energy production.
Mitochondrial DNA (mtDNA): Circular DNA molecule found in mitochondria.
Inheritance Pattern: Maternally inherited, meaning it is passed from mothers to all their offspring.
Diseases: Examples include Leber’s hereditary optic neuropathy (LHON) and mitochondrial myopathy.
Slide 4: Chloroplast Inheritance
Chloroplasts: Organelles responsible for photosynthesis in plants.
Chloroplast DNA (cpDNA): Circular DNA molecule found in chloroplasts.
Inheritance Pattern: Often maternally inherited in most plants, but can vary in some species.
Examples: Variegation in plants, where leaf color patterns are determined by chloroplast DNA.
Slide 5: Plasmid Inheritance
Plasmids: Small, circular DNA molecules found in bacteria and some eukaryotes.
Features: Can carry antibiotic resistance genes and can be transferred between cells through processes like conjugation.
Significance: Important in biotechnology for gene cloning and genetic engineering.
Slide 6: Mechanisms of Extrachromosomal Inheritance
Non-Mendelian Patterns: Do not follow Mendel’s laws of inheritance.
Cytoplasmic Segregation: During cell division, organelles like mitochondria and chloroplasts are randomly distributed to daughter cells.
Heteroplasmy: Presence of more than one type of organellar genome within a cell, leading to variation in expression.
Slide 7: Examples of Extrachromosomal Inheritance
Four O’clock Plant (Mirabilis jalapa): Shows variegated leaves due to different cpDNA in leaf cells.
Petite Mutants in Yeast: Result from mutations in mitochondrial DNA affecting respiration.
Slide 8: Importance of Extrachromosomal Inheritance
Evolution: Provides insight into the evolution of eukaryotic cells.
Medicine: Understanding mitochondrial inheritance helps in diagnosing and treating mitochondrial diseases.
Agriculture: Chloroplast inheritance can be used in plant breeding and genetic modification.
Slide 9: Recent Research and Advances
Gene Editing: Techniques like CRISPR-Cas9 are being used to edit mitochondrial and chloroplast DNA.
Therapies: Development of mitochondrial replacement therapy (MRT) for preventing mitochondrial diseases.
Slide 10: Conclusion
Summary: Extrachromosomal inheritance involves the transmission of genetic material outside the nucleus and plays a crucial role in genetics, medicine, and biotechnology.
Future Directions: Continued research and technological advancements hold promise for new treatments and applications.
Slide 11: Questions and Discussion
Invite Audience: Open the floor for any questions or further discussion on the topic.
This pdf is about the Schizophrenia.
For more details visit on YouTube; @SELF-EXPLANATORY;
https://www.youtube.com/channel/UCAiarMZDNhe1A3Rnpr_WkzA/videos
Thanks...!
2. Overview
Double Beam UV-Vis Spectrophotometer LUS-B10 is a compact, tabletop
double beam designed UV-Vis spectrophotometer comprising Silicon
photodiode detector, Tungsten and Deuterium lamp as light source.
Equipped with wide wavelength range of 190 nm to 1100 nm, it offers 1.8
nm of bandwidth with automatic setting of wavelength. Designed with 6
inches LCD display, import source and receiver system, it provides rich
measurement methods with high performance and reliability.
Specifications :
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 1.8 nm
Optical System Double beam
Wavelength Accuracy ±0.3 nm
Wavelength Repeatability ≤0.1 nm
Wavelength Resolution 0.1 nm
Photometric Display Range -4 to 4 A
Photometric Mode T, A, C, E
Photometric Accuracy
±0.3% τ (0 to 100%τ) ± 0.002 A (0 to
0.5 A) ± 0.003 A (0.5 A to 1 A)
Photometric Repeatability
0.15% τ (0 to 100% τ) ± 0.001 A (0 to
0.5 A) ± 0.0015 A (0.5 A to 1 A)
Light Source Tungsten lamp, Deuterium lamp
Stray Light ≤0.03% τ (220 nm NaI, 340 nm NaNO )
2
Stability 0.0005 A/h @500 nm
Noise ± 0.002 A @500 nm
3. Display
6 inches high brightness Blue LCD
display
Baseline Flatness ± 0.001 A
Detector Silicon photodiode
Power Supply AC 220/110 V, 50/60 Hz
Dimensions (L×W×H) 560×450×230 mm
Net Weight 28 kg
Features :
- Compact, tabletop double beam designed UV-Vis spectrophotometer
- Silicon photodiode detector, Tungsten and Deuterium lamp as light
source
- Wide wavelength range of 190 nm to 1100 nm with automatic setting
- 6 inches high brightness blue LCD display
- Import source and receiver system
- Measurement methods: wavelength scan, time scan, multi-wavelength
determination, multi-order derivative determination, dual-wavelength,
three-wavelength, DNA protein measurements etc.
- High performance and reliability with user-friendly interface
Applications :
Double Beam UV-Visible Spectrophotometer are used for analysis of band
gap, optical coatings and thin films, quantitative analyses, kinetics,
wavelength scanning, and DNA and Protein analysis across biological
research, bio-industry, pharmaceutical analysis, pharmaceutical, teaching
and research, environmental protection, food hygiene, clinical
examination, health and epidemic prevention and other fields.