SlideShare a Scribd company logo
08
Technical parameter:
Pole
Rated Voltage(Un)
Rated Current IN
Rated frequency fN
Rated breaking capacity
Energy limiting class
Tripping characteristic
1, 2, 3, 4
230(240)/400(415)V AC, max.60V DC
0.5-63A
50HZ
6KA
3
B,C,D
B
EN 50022
18mm/pole
IEC 60898, EN60898
2
1-25mm
Isolating class
Mounting on the rail
Build-in width
Standards
Cross-section of
connecting lead
77=0.8
45
35.6=0.3
44
65.7
5.5
80=0.8
18
Dimensions(mm):
Operation Principle Fig:
1Pole
1
2
2Pole
1
2
3
4
N
N
3Pole
1
2
3
4
5
6
4Pole
1
2
3
4
5
6 8
7 N
N
Technical parameter:
Pole
Rated Voltage(Un)
Rated Current IN
Rated frequency fN
Rated breaking capacity
Energy limiting class
Tripping characteristic
1, 2, 3, 4
230(240)/400(415)V AC, max.60V DC
0.5-63A
50HZ
6KA
3
B,C,D
B
EN 50022
18mm/pole
IEC 60898, EN60898
2
1-25mm
Isolating class
Mounting on the rail
Build-in width
Standards
Cross-section of
connecting lead
77=0.8
45
35.6=0.3
44
65.7
5.5
80=0.8
18
Dimensions(mm):
Operation Principle Fig:
1Pole
1
2
2Pole
1
2
3
4
N
N
3Pole
1
2
3
4
5
6
4Pole
1
2
3
4
5
6 8
7 N
N
OLB7-1P/2P
Miniature Circuit Breaker
OLB7-3P
Miniature Circuit Breaker
www.meba.net
Miniature
Circuit Breaker
OLB7-3POLB7-1P/2P
BH Miniature Circuit Breaker
Features and Applications:
BH seriesminiature circuit breakeris characteristicof smallsize,
light weight,novel structure and excellent performance. They
are mounted in the illuminating distribution board and used in
guest house s, block of flats, high buildings, squar es, airports,
railway stations, plants and enterprises etc. inACcircuits 240V
(single pole) up to 415V(3 pole) 50Hz for protection of overload
short circuit and forcircuit change-over in lighting sys tem. Breaking
capacity is 3KA. The items comply with IEC60898 standard.
Technical parameter:
Number of Poles
Rated Current (A)
Rated Voltage(V)
Breaking Capacity(A)
Electrical Life(Times)
Mechanical Life(Times)
1P,2P,3P
6, 10, 15, 20, 25, 30, 40, 50, 63, 70,80, 90, 100
110/220 (1P), 240/415 (2P), 415(3P)
3000
6000
16000
Dimension(mm):
75
50
25
95
3P
2P
1P
77
64
100
BH-P Miniature Circuit Breaker
Applications:
BH-P series miniature circuit breaker applies to industrial,
commerical, lighting and electric machine distrib ution system
with AC415V, 50/60Hz, ratedworking currentup to100Ato protect
against overload and short circuit.The itemis installed intoplug-in
type mounting base.
Technical parameter:
Number of Poles
Rated Current (A)
Rated Voltage(V)
Breaking Capacity(A)
Electrical Life(Times)
Mechanical Life(Times)
1P,2P,3P
6, 10, 15, 20, 25, 30, 40, 50, 63, 70,80, 90, 100
110/220 (1P), 240/415 (2P), 415(3P)
3000
6000
16000
Dimension(mm):
25
20.7
30
ON
SOFAB
57.4
75
89
77
64.2
61
75
57.4
www.meba.net
Miniature
Circuit Breaker
BH
09
BH-P
www.mebamfg.com
Miniature
Circuit Breaker
MBGLD4/MBGLD4A Miniature Circuit Breaker
Specification needs:
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBGLD4/ MBGLD4A
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35 mm
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10
times rated current ( Type C ), 3 to 5 times rated current ( Type B ), 10 to 14 times rated current ( TypeD )
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the
trigger mechanism in the presence of an overload or short circuit.
CE CB
ISO9001-2000awarded bythecompetentcertification body, Mebais qualifiedinthemanufacturing ofthe object
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
The packaging is sure that withstand anyadverse conditions duringtransport and handling to the warehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
A
Vac
Hz
kA
2
mm
A
93% RH at 25 50% RH at 40
-5 a 40
6/10/16/20/25/32/40/50/63
240/415
50/60
6
-5 a 40
IP20
1/2/3/4
25
4000
8000
B/C/D
Type B: 3 a 5 In Type C: 5 a10 In Type D: 10 a 14 In
attach
10
MBGLD4AMBGLD4
MBBH Miniature Circuit Breaker
Applications:
MBBH series miniature circuit breaker, major export to South America, Middle East market, has light weight, smallsize, novel structure
and excellent performance. They are mounted in the metal distribution boar d and used in guesthouses. block of fiats, high buildings,
squares, airpo rts, railway stations, plants and enterprises etc, in AC circuits 240V(single pole) up to 415V(3poie) 50Hz for protectionof
overload short circuitand for circuitchangeover in lightingsystem. Breaking capacityis 3KA.The items complywith BS&NEMASTANDARD.
Specification needs:
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century, Year, Month and Batch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
A
Vac
Hz
kA
2
mm
A
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBBH
IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
NEMA Type
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times
rated current (Type C), 10 to 14 times rated current ( Type D)
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectively dissipates the electric arcthat is generatedby the openingcontacts of thetrigger
mechanism in the presence of an overload or short circuit.
CE
ISO 9001-2000 awardedby the competent certification body, Meba is qualifiedin the manufacturingof the object
IEC 60947 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving thecircuit breakers (breakers),customers may performthe tests maybe necessary toensure
compliance with the technical specifications.
The packaging is sure that withstand any adverse conditions during transport and handling to the warehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
93% RH at 25
10 a 60
6/10/15/20/30/40/50/60
120/240/415
50/60
3
-5 a +40
IP20
1, 2, 3, 4
25
4000
6000
B/C/D
Type B 3 a 5 In Type C 5 a 10 In Type D 10 a 14 In
attach
www.meba.net
Miniature
Circuit Breaker
11
MBBH
MABD Miniature Circuit Breaker
Specification needs:
Manufacturer: Meba Electric Enterprises
Country of Origin: china
Brand: meba
Model: MABD
IEC 60898 IEC60947-2
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230 V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
NEMA TYPE
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to
10 times rated current (Type C).
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of
the trigger mechanism in the presence of an overload or short circuit.
Semko CB
ISO9001-2000, awardedby the competentcertification body, Mebais qualifiedin the manufacturingof the object
IEC 60898 standards awarded by an international certifying body.
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receivingthe circuit breakers (breakers), customers may perform the tests may be necessary
to ensure compliance with the technical specifications.
The packaging is sure that withstand any adverse conditions during transport and handling to the
warehouse of cutomers.
In one of its sides the breaker is marked with the symbol permanent ink, year, month and batch.
Attach catalogs indicating the technical specifications
Submit sample of the product offered
2 YEARS
CNF & FOB
25 DAYS
A
Vac
Hz
kA
93% RH at 25
10 a 60
6110/6/20/25/32/40/50/63
120/240/415
50/60
6
40
IP20
1/2/3/4
25
4000
8000
B/C/D
5 a 10 In
attach
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month and Batch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
2
mm
A
www.meba.net
Miniature
Circuit Breaker
12
MABD
Applications:
GV series motor protection circuit breaker are mainly used for the overload and short circuit protection of motors in AC50/60Hz, up to
660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motors, under the AC3 load or for the overload and short circuit
protection of the circuitand power equipment in the power in the power distribution network.
Technical parameter:
Standard power ratings of 3-phase motors
50/60Hz in category AC-3
Type Setting range
0.1-0.16
0.16-0.25
0.25-0.4
0.4-0.63
0.63-1
1-1.6
1.6-2.5
2.5-4
4-6
6-10
10-16
16-20
20-25
0.1-0.16
0.16-0.25
0.25-0.4
0.4-0.63
0.63-1
1-1.6
1.6-2.5
2.5-4
4-6.3
6-10
9-14
13-18
17-23
20-25
24-32
660V
KW
--
--
--
0.37
0.55
1.1
1.5
3
4
7.5
11
15
18.5
--
--
--
0.37
0.55
1.1
1.5
3
4
7.5
9
11
15
18.5
26
500V
KW
--
--
--
--
0.37
0.75
1.1
2.2
3.7
5.5
10
11
15
--
--
--
--
0.37
0.75
1.1
2.2
3.7
5.5
7.5
9
11
15
18.5
440V
KW
--
--
--
--
0.37
0.55
1.1
1.5
3
4
7.5
9
11
--
--
--
--
0.37
0.55
1.1
1.5
3
4
7.5
9
11
11
15
415V
KW
--
--
--
--
--
--
1.1
1.5
2.2
4
7.5
9
11
--
--
--
--
--
--
0.75
1.5
2.2
4
5.5
9
11
11
15
380V
KW
--
--
--
--
--
0.37
0.75
1.5
2.2
4
7.5
10
11
--
--
--
--
--
0.37
0.75
1.5
2.2
4
5.5
7.5
11
11
15
220V
KW
--
--
--
--
--
--
0.37
0.75
1.1
2.2
4
5.5
5.5
--
--
--
--
--
--
0.37
0.75
1.1
2.2
3
4
5.5
5.5
7.5
GV1-M01
GV1-M02
GV1-M03
GV1-M04
GV1-M05
GV1-M06
GV1-M07
GV1-M08
GV1-M10
GV1-M14
GV1-M20
GV1-M21
GV1-M22
GV2-M01/RS01
GV2-M02/RS02
GV2-M03/RS03
GV2-M04/RS04
GV2-M05/RS05
GV2-M06/RS06
GV2-M07/RS07
GV2-M08/RS08
GV2-M10/RS10
GV2-M14/RS14
GV2-M16/RS16
GV2-M20/RS20
GV2-M21/RS21
GV2-M22/RS22
GV2-M32/RS32
www.meba.net
Miniature
Circuit Breaker
GV2-M10/GV2ME Miniature Circuit Breaker
13
GV2-M10 GV2ME
18
79
36
45
45
Features and Applications:
Dimension(mm):
C45D Indicator
Din Rail type LED Indicator, Neon Signal Lamp
The DIN Rail type Modular Signal Lamp is applicable to circuit
with rated voltage 230V AC, 50/60Hz for visual indication and
signaling.
Low service duration, minimum power consumption
Compact design in modular size, easy installation
Rated voltage: 230V AC, 50/60Hz
Colour: Red, green, yellow
Connection terminal: Pillar terminal with clamp
2
Connection capacity: Rigid conductor 10mm
Installation: - On symmetrical DIN rail
- Panel mounting
Illumination type:
A. Illumination: LED
- Max power: 0.6W
- Service duration: 30, 000 hours
B. Illumination: Neon bulb
- Max power: 1.2W
- Service duration: 15, 000 hours
CPKZM0-1.0 Miniature Circuit Breaker
CPKZ M0 Motor Protective Circuit Breaker isapplicable for the
circuit of AC50/60Hz, rated insulation voltage 750V, rated
operating voltage up to 660V, rated operating current from
0.1A to 25A. Itis used forprotecting the motoragainst overlo ad,
short-circuit and phase-failure. It can bealso used forstarting
and breaking the starter of motor and for the circuit protection
in the circuit of 25A.
Motor Protective Circuit Breakers (CPKZM)
Features and Applications:
Screw or DIN rail mounting
Thermal and electromagnetic trip
Rated operational current up to 25A
Switching capacity 150/50KA/415V
Short-circuit release, fixed setting to 14X Iu
Single-phasing sensitive
With screws or spring loaded terminals
Comply with IEC/EN6094
Technical parameter:
Standard
power ratings
of 3-phase
motors 50/60Hz
in category
AC-3(kW)
Setting range
of overload
tripping
current Ir(A)
Norminal
breaking
capacity(A)
Rated
operating
current 400V
Ie(A)
Reference
-
0.06
0.09
0.12
0.25
0.55
0.75
1.5
2.2
3
4
5.5
7.5
9
12.5
0.1-0.16
0.16-0.25
0.25-0.4
0.4-0.63
0.63-1
1-1.6
1.6-2.5
2.5-4
4-6.3
6.3-10
6.3-10
10-16
10-16
16-20
20-25
100
100
100
100
100
100
100
100
100
100
100
50
50
50
50
0.16
0.25
0.4
0.63
1
1.6
2.5
4
6.3
6.6
10
16
16
20
25
CPKZM0-01
CPKZM0-02
CPKZM0-03
CPKZM0-04
CPKZM0-05
CPKZM0-06
CPKZM0-07
CPKZM0-08
CPKZM0-10
CPKZM0-14
CPKZM0-16
CPKZM0-20
CPKZM0-21
CPKZM0-22
CPKZM0-32E
www.meba.net
Miniature
Circuit Breaker
14
C45DCPKZM0-1.0
C45N Miniature Circuit Breaker
Features and Applications:
C45N series miniature circuit breaker isused in lightingdistribution
system or motor distribution system for protection overload and
short-circuit in the system. The product is neoteric in structure,
light in weight, reliable and excellent in performance. It has high
breaking capacity, can trip quickly, and its case and items are
adoptedby highfire-resistant and shockproofplastics. The product,
with long life, is mainly used in AC 50Hz/60Hz single-pole 230V
or two, three,four pole 400Vcircuit for overloadand short-circuit
protection as well as forunfrequent on-and-off switching electric
equipment and lighting circuit innormal case. The products comply
with IEC 60898.
Technical parameter:
Number of Poles
Rated Current (A)
Breaking Capacity (A)
Rated Voltage (V)
Rated Frequency
Endurance
Circumstance Temperature
Electrical Life
Mechanical Life
1P,1P+N, 2P, 3P, 3P+N, 4P
1, 2, 3, 4, 6, 10, 16, 20, 25, 32,40, (50, 63)
6000, (4500)
230/400
50/60Hz
4000
-5+40
no less than 6000 operations
(O-C) no less than 20000 operations
Characteristic Curve:
10000
5000
1H
2000
1000
500
200
100
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001
0.5 1 2 3 4 5 7 10 20 30 5 0 70 100 200 I /1K
t(s)
B type 3-5In
C type 5-10In
D type 10-14In
short circuit prospective short-circuit
current peak value
prospective
short-circuit energy
Current-limiting peak value
Current-limiting
short-circuit energy times
0 2ms 10ms
Dimension(mm):
4P
3P
2P
1P
72
54
36
18
70
40
77
45
35 27
75
L
www.meba.net
Miniature
Circuit Breaker
15
C45N
AEG E90 E91 E92 E93 S90 S91 S92 S93 Miniature circuit
breaker (MCB)
NEW AEG E90 E91 E92 MCB
Rated Current: 6-63A
Quality guarantee: 5 years
CE CB certificated
Applications:
The productis mainly used inAC50/60Hz single pole230V or two,
three, four pole400Vvoltage for overload and short-circuitprotection
as well asfor unfrequenton-and-off switching electric equipment
and lighting circuitunder nrmal conditionl, the productis suitabl e
for industry, business, building, ressidenc e, etc. It's conformity
with GB10963, IEC60898 standards.
C47-3P Miniature Circuit Breaker
Characteristic Curve:
10000
5000
1H
2000
1000
500
200
100
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001
0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/1K
t(s)
B type 3-5In
C type 5-10In
D type 10-14In
Technical parameter:
Rated current: 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A
Tripping characteristics: B(3-5)In, C(5-10)In, D(10-15)In
No. of pole: 1P, 2P, 3P, 4P
Breaking capacity: 4.5KA, 6KA
Standard
Number of poles
Rated current(In)
Rated voltage(Un)
Rated frequency
Tripping curve
Release action characteristics
Magnetic releases operate
Rated breaking capacit(Lcn)
Endurance
Circumstance temperature
Electrical life
Mechanical life
Tropical ration
Protection degree
IEC60898
1P,2P,3P,4P
6, 10, 16, 20, 25, 32, 40, 50, 63
AC240/415V
50/60Hz
B, C, D
1.13In>1h Non-trip
1.45In<1h trip
2.55In 1s-60S trip
5In>0.1s Non-trip
10In<0.1s trip
B curve:between 3 and 5In
C curve:between 5 and 10In
D curve:between 10 and 15In
3000A
>2500
-5 to +40
>6000times
20000 times
Treatmen 2(RH95%, at 55)
IP20
Time delay
Instantaneous(Curve C)
Miniature
Circuit Breaker
www.meba.net
16
C47-3P
35 27
75
L
10000
5000
0.5 1 2 34 5 7 10 20 30 50 70 100 200 I/1K
B 3-5In type
C 5-10In type
D 10-14In type
2000
1000
500
200
100
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001
Characteristic Curve:
18 0.9 36 1.25 54 1.5
72 1.5 49.5 1.25
73 1.5
81
35.51.25
45.51.25
Standard
IEC898
IEC847-2
Rated current (A)
1, 2, 3, 4, 5, 6, 10, 16, 20, 25, 32, 40, 50, 63A
1, 2, 3, 4, 5, 6, 10, 16, 20, 25, 32, 40, 50, 63A
Character Voltage (V)
230/240
380/415
130
230/240
400/415
230/240
400/415
Pole
1
2, 3, 4
1
Breaking Capacity (A)
6000
6000
20000
10000
3000
20000
10000
2, 3, 4
B
C
D
Features and Applications:
C65N Miniature Circuit Breaker
The products of C65N belong to the advanced level of nineties in
the international instead of the older generation of C45N. They
have protective function as shortage and overload, and are used
in lighting distributionsystem in industry, commerce and dwelling,
and protecting fractional electrical motors. And they also have
many merits of high protective grade (up to IP20), high breaking
capacity, reliable sensitive action, convenient , multipole
assembling long lifeetc. They are mainly adapted to the circuit of
AC 50Hz, 230V in single pole, 400V in double, three, four poles
for protecting overloadand shortcircuit. Meanwhile, theyare also
used in turningon or off the electrical apparatus and lighting circuit
under the normal conditions.
Technical parameter:
Dimension(mm):
www.meba.net
Miniature
Circuit Breaker
17
C65N
XYDB7-3P Miniature Circuit Breaker
Features and Applications:
XYDB7 have protective function as shortage as overload, and used in lighting distribution system, industry, commerce, and protect
fractional electric motors. And they also have many merits of high protective grade (upto IP20), high break capacity, reliable sensitive
action, convenient, multipol e assembling, long life etc. They are mainly adapted to the circuit of AC 50Hz,230V in single pole,400V in
double, three, fourpoles for protectingoverload and shortcircuit. Meanwhile, theyare also usedin turning on oroff the electric apparatus
and lighting circuit under the normal condition.
Technical parameter:
Electrical specification
Conforms to standard of electrical
EN60898 (IEC898 GB10963-99)
230V/400V; 50/60Hz
10KA IEC898 (0.5 63A)
15KA IEC947-2 (0.5 63A)
Max.48V (KL7..., 10KA) single pole
Max.250v (Kl7-DC, 6KA) single pole
C,D charaectisistic curve
100AgL ( 10KA)
3
-5 to + 40
P40 (Under mounting)
No less than 8000 times
No less than 20000 times
45mm
80mm
17.5mm per pole (single pole)
35mm: 1P+N (two pole)
Used for track of 35mm of IEC standard
Two-function terminal can connect with busbar and conducting wire
2
Wire 1-25mm
Conducting wire 0.8-2mm
Terminal block capacity
Enclosure width
The length of exposed plane
Enclosure height
Life: Electrical Mechnical
Perfermance
Max.fuse that can be connected to
Selective grade
Working ambient temperature
Enclosed protective class
Short circuit breaking capacity of DC
Rated current (Ue)
Mounting manner
Terminal manner
Miniature
Circuit Breaker
www.meba.net
18
XYDB7-3P
Specification needs:
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
Operation Indicator Window
A
Vac
Hz
kA
2
mm
A
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MB1-63
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230 V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve C
Characteristic Intervention
FOR RIEL DIN 35 mm
The circuit breaker have an operating window colordisplay that shows the state inwhich it is ( connected
or disconnected ).
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10
times rated current ( TypeC ), 3 to 5 times rated current ( Type B), 10 to 14 times rated current ( Type D )
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of
the trigger mechanism in the presence of an overload or short circuit.
CE CB
ISO9001-2000awarded bythe competentcert ifica tion body, Mebais qualifi ed in the manufacturing of the object
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary
to ensure compliance with the technical specifications.
The packaging is sure that withstand any adverse conditions during transport and handling to the
warehouse of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
93% RH at 25
10 a 60
6/10/16/20/25/32/40/50/63
240/415
50/60
6
40
IP20
1/2/3/4
25
4000
10000
B/C/D
5 a 10 In
attach
MB1-63 Miniature Circuit Breaker
www.meba.net
Miniature
Circuit Breaker
19
MB1-63
Charcteristic Curve:
10000
5000
B type
2000
1000
500
200
100
50
0.2
0.1
20
10
5
2
1
0.5
0.05
0.02
0.01
0.005
0.002
0.001
Time(s)
0.5 1 2 3 4 5 7 10 20 30 50 70 100 200
I/In
10000
5000
C type
2000
1000
500
200
100
50
0.2
0.1
20
10
5
2
1
0.5
0.05
0.02
0.01
0.005
0.002
0.001
Time(s)
0.5 1 2 3 4 5 7 10 20 30 50 70 100 200
I/In
10000
5000
D type
2000
1000
500
200
100
50
0.2
0.1
20
10
5
2
1
0.5
0.05
0.02
0.01
0.005
0.002
0.001
Time(s)
0.5 1 2 3 4 5 7 1014 20 30 50 70 100 200
I/In
MB1-63 Miniature Circuit Breaker
Dimension(mm):
4P
3P
2P
1P
72
54
36
18
82
35
45
76
Miniature
Circuit Breaker
www.meba.net
20
MB1-63
Specification needs:
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
Operation Indicator Window
A
Vac
Hz
kA
2
mm
A
93% RH at 25
10 a 60
6/10/16/20/25/32/40/50/63
240/415
50/60
10
40
IP20
1 1+N 2 3 3+N 4
25
4000
8000
B/C/D
Type B 3 a 5 In Type C 5 a 10 In Type D 10 a 14 In
attach
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MB7
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230 V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35 mm
The circuit breaker have an operating window color display that shows the state in which it is ( connected
or disconnected ).
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following range s: 5 to 10
times rated current ( TypeC ), 3 to 5 times rated current ( Type B), 10 to 14 times rated current ( Type D )
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the
trigger mechanism in the presence of an overload or short circuit.
CE CB
ISO9001-2000 awarded by thecompetent certification body, Mebais qualified in themanufacturing of theobject
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
The packaging is surethat withstandany adverse conditions duringtransportand handling to thewarehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
MB7 Miniature Circuit Breaker
www.meba.net
Miniature
Circuit Breaker
21
MB7
MB7 Miniature Circuit Breaker
Dimension(mm):
35 52.5 70
2P 3P 3P+N
80 80 80
70
4P
80
17.5
80
1P
1P+N
26.3
8045
11
44
30.5 4.55.5
60
Dimension(mm):
MB040 Time Relay
18
63.5
44.5
45.5
35
95
6
Miniature
Circuit Breaker
www.meba.net
22
MB040MB7
MB040 Time Relay
Specification needs:
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
A
Vac
Hz
kA
2
mm
A
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MB040
IEC 60898
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35 mm
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10
times rated current ( TypeC ).
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the
trigger mechanism in the presence of an overload or short circuit.
ISO 9001-2000
IEC 60898 standards
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by us to ensure that the life of the goods offered by atleast 5 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
We are surethe packaging withstandany adverse conditionsduring transp ort and handling to the cellar s
of the Company. Carton or Pallet
In one of its sides the breaker is marked with the symbol permanent ink, year, month and batch.
Available
Submit sample of the product offered
2 YEARS
CIF CNF FOB
25 Days
93% RH at 25
10 a 60
6/16/20/25/32
120/240/415
50/60
3/4.5/6
40
IP20
1
25
4000
8000
C
5 a 10 In
attach
www.meba.net
Miniature
Circuit Breaker
23
MB040
MB043 Isolator
Specification needs:
Electrical Properties
Type of Assembly
Present Certificates
Testing For Acceptance
Packing
Dial Century, Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
A
Vac
Hz
kA
2
mm
A
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MB043 Isolator
IEC 60947-3
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35 mm
ISO 9001-2000
IEC 60947-3 standards
Life, given by us to ensure that the life of the goods offered by atleast 5 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
We are surethe packaging withstandany adverse conditions during transport and handling to the cellars
of the Company. Carton or Pallet
In one of its sides the breaker is marked with the symbol permanent ink, year, month and batch.
Available
Submit sample of the product offered
2 YEARS
CIF CNF FOB
25 Days
93% RH at 25
10 a 60
6/16/20/25/32
120/240/415
50/60
0
40
IP20
1/2/3/4
25
4000
8000
/
/
attach
Miniature
Circuit Breaker
www.meba.net
24
MB043
MB32 DPN
Applications:
MB32 series is mainly for protecton of circuits with AC220V and 50Hz/60Hz, and for unfrequent conversion under normal conditions as
well. Its action can be up to two pole with its only one pole volume and be used as a leakage breaker by assembling with leakage. It is
produced perEN60.898,IEC947-2 standards.
Over-current tripping characteristic:
Tripping
Tripping rated
current(InA)
Beginning state Test current Norminative Time Test result Note
C
Cold state
Heat state
Cold state
Cold state
Cole state
1.13In
1.45In
2.55In
5In
10In
t 1h
t 1h
1s t 60s
t 0.1h
t 0.1s
No tripping
Tripping
Tripping
No tripping
Tripping
Close auxillzry switch
making the circuit
40
The current will rise to
norminative value in 5s
Main Technical Data:
Rated current A
6 10 16
20 25 32 40
Pole NO
1P+N
Rated
voltage(V)
240/415
Breaking
capacity(KA)
4.5
Instantaneous
Tripping type
C
Instantaneous
Protection current range
5In I 10In
Electric life
5000
Dimension(mm):
44.5
77
18
80
36
45
www.meba.net
Miniature
Circuit Breaker
25
MB32
Specification needs:
MB32 DPN
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
A
Vac
Hz
kA
2
mm
A
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MB32
IEC 60898 IEC947-2
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230 V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35 mm
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10
times rated current ( TypeC ).
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the
trigger mechanism in the presence of an overload or short circuit.
CE
ISO9001-2000 awardedby thecompetentcertification body,Mebais qualifiedin themanufacturing of the object
IEC 60898 standards in the manufacture of the goods awarded by an international certifying body.
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customer may perform the tests may be necessary to
ensure compliance with the technical specifications.
The packaging is sure that withstand any adverse conditionsduring transport andhandling to thewarehouse
of customer
In one of its sides the breaker should be marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specifications
Submit sample of the product offered
2 YEARS
FOB CIF
25 Days
93% RH at 25
10 a 60
6/10/16/20/25/32/40
240/415
50/60
4.5
40
IP20
1P+N
25
5000
10000
C
5 a 10 In
attach
Miniature
Circuit Breaker
www.meba.net
26
MB32
www.meba.net
Specification needs:
Miniature
Circuit Breaker
MBL10 Miniature Circuit Breaker
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
Operation Indicator Window
93% RH at 25
10 a 60
6/10/16/20/25/32/40/50/63
240/415
50/60
6
40
IP20
1/2/3/4
25
4000
10000
B/C/D
5 a 10 In
attach
A
Vac
Hz
kA
2
mm
A
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBL10
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve C
Characteristic Intervention
FOR RIEL DIN 35mm
The circuit breaker have an operating window color display that shows the state in which it is (connected
or disconnected).
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10
times rated current (Type C), 3 to 5 times rated current ( TypeB ), 10 to 14 times rated current ( Type D )
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the
trigger mechanism in the presence of an overload or short circuit.
CE CB
ISO 9001-2000awarded by thecompetent certification body, Meba isqualified in themanufactu ring of the object
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
The packaging issure thatwithstandany adverse conditions during transportand handling to the warehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
27
MBL10
MBL11 Miniature Circuit Breaker
Specification needs:
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
Operation Indicator Window
A
Vac
Hz
kA
2
mm
A
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBL11
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve C
Characteristic Intervention
FOR RIEL DIN 35mm
The circuit breaker have an operating window color display that shows the state in which it is (connected
or disconnected).
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10
times rated current (Type C), 3 to 5 times rated current ( TypeB ), 10 to 14 times rated current ( TypeD )
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the
trigger mechanism in the presence of an overload or short circuit.
CE CB
ISO9001-2000 awardedby the competentcertifica tion body, Mebais qualified inthe manufacturing of the object
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
The packaging issure that withstandany adverse condition s during transport and handling to the warehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
93% RH at 25
-5 a 40
6/10/16/20/25/32/40/50/63
240/415
50/60
6
-5 a 40
IP20
1/2/3/4
25
6000
20000
B/C/D
5 a 10 In
attach
www.meba.net
Miniature
Circuit Breaker
28
MBL11
Applications:
Protection and control of circuit against overlo ad and short circ uit,
in building installation-suchas houses, office s, commercial complex,
motorsystem (D curve) and industrial installation-for switching,
control, protection and regulation of electrical circuits. Also in
switchgear panels, railway and marine application.
Overall and mounting dimensioned chart:
18
36
54
72
70
50
73
36
81
45
MB47-1P/2P
Miniature Circuit Breaker
18
36
54
72
80
36
50
66
76
45
www.meba.net
Miniature
Circuit Breaker
MBL11 Miniature Circuit Breaker
Overall & Installation Dimensions:
29
MBL11 MB47-1P
Miniature
Circuit Breaker
www.meba.net
MB47-1P/2P Miniature Circuit Breaker
Specification needs:
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
A
Vac
Hz
kA
2
mm
A
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MB47-1P/ 2P
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35 mm
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10
times rated current ( TypeC ), 3 to 5 times rated current ( Type B), 10 to 14 times rated current ( Type D )
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the
trigger mechanism in the presence of an overload or short circuit.
CE CB
ISO9001-2000awarded by thecompetent certification body, Meba is qualifiedinthemanufacturing of theobject
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
The packaging is sure that withstand any adverse conditions during transport and handling to the warehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
93% RH at 25 50% RH at 40
-5 a 40
6/10/16/20/25/32/40/50/63
240/415
50/60
6
40
IP20
1/2/3/4
25
4000
8000
B/C/D
Type B: 3 a 5 In Type C: 5 a 10 In Type D: 10 a 14 In
attach
30
MB47-2PMB47-1P
www.meba.net
Miniature
Circuit Breaker
MB48/MB49 Miniature Circuit Breaker
Specification needs:
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MB48/ MB49
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35 mm
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10
times rated current ( TypeC ), 3 to 5 times rated current ( Type B), 10 to 20 times rated current ( Type D )
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the
trigger mechanism in the presence of an overload or short circuit.
CE CB
ISO 9001-2000awarded by the competent certification body, Mebais qualified in themanufactu ring of theobject
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
The packaging is sure that withstand any adverse conditio ns during transport and handling tothe warehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
A
Vac
Hz
kA
2
mm
A
93% RH at 25
10 a 60
6/10/16/20/25/32/40/50/63
240/415
50/60
6
40
IP20
1/2/3/4
25
4000
10000
B/C/D
5 a 10 In
attach
31
MB48 MB49
Miniature
Circuit Breaker
www.meba.net
MB50/MB51 Miniature Circuit Breaker
Specification needs:
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Tropicalization
2
mm
A
Manufacturing Standards
A
Vac
Hz
kA
93% RH at 25
10 a 60
6/10/16/20/25/32/40/50/63
240/415
50/60
6
40
IP20
1/2/3/4
25
4000
10000
B/C/D
5 a 10 In
attach
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MB50/ MB51
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35 mm
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10
times rated current ( TypeC ), 3 to 5 times rated current ( Type B), 10 to 20 times rated current ( Type D )
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the
trigger mechanism in the presence of an overload or short circuit.
CE CB
ISO 9001-2000 awarded by the competent certification body,Meba isqualified in the manufacturing of the obj ect
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
The packaging is sure that withstand any adverse conditions during transport and handling to thewarehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
32
MB51MB50
www.meba.net
Miniature
Circuit Breaker
Specification needs:
MB52 Isolator
Electrical Properties
Type of Assembly
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
A
Vac
Hz
kA
2
mm
A
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MB52 Isolator
IEC 60947-3
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35 mm
The breaker have an operating window color display that shows the state in which it is ( connected or
disconnected ).
CE
ISO 9001-2000
IEC 60947-3 standards
Life, given by us to ensure that the life of the goods offered by atleast 5 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
We are surethe packaging withstand any adverse conditions during transport and handling to the cellars
of the Company. Carton or Pallet
In one of its sides the breaker is marked with the symbol permanent ink, year, month and batch.
available
Submit sample of the product offered
2 YEARS
CIF CNF FOB
25 Days
93% RH at 25
10 a 60
6/16/20/25/32/40/50/63
240/415
50/60
0
40
IP20
1/2/3/4
25
4000
8000
/
/
attach
Operation Indicator Window
33
MB52
Miniature
Circuit Breaker
www.meba.net
MB52 Miniature Circuit Breaker
Specification needs:
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MB52 MCB
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35 mm
The circuit breaker have an operating window color display that shows the state in which it is ( connected
or disconnected ).
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10
times rated current ( TypeC ), 3 to 5 times rated current ( Type B), 10 to 20 times rated current ( Type D )
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the
trigger mechanism in the presence of an overload or short circuit.
CE CB
ISO 9001-2000awarded by the competent certificat ion body, Mebais qualified in themanufacturing of the object
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
The packaging issure that withstand any adverse conditions during trans port and handling to the warehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
A
Vac
Hz
kA
2
mm
A
93% RH at 25
10 a 60
6/10/16/20/25/32/40/50/63
240/415
50/60
6
40
IP20
1/2/3/4
25
4000
10000
B/C/D
5 a 10 In
attach
Operation Indicator Window
34
MB52
MB52 Miniature Circuit Breaker
Charcteristic Curve:
10000
5000
B type
2000
1000
500
200
100
50
0.2
0.1
20
10
5
2
1
0.5
0.05
0.02
0.01
0.005
0.002
0.001
Time(s)
0.5 1 2 3 4 5 7 10 20 30 50 70 100 200
I/In
10000
5000
C type
2000
1000
500
200
100
50
0.2
0.1
20
10
5
2
1
0.5
0.05
0.02
0.01
0.005
0.002
0.001
Time(s)
0.5 1 2 3 4 5 7 10 20 30 50 70 100 200
I/In
10000
5000
D type
2000
1000
500
200
100
50
0.2
0.1
20
10
5
2
1
0.5
0.05
0.02
0.01
0.005
0.002
0.001
Time(s)
0.5 1 2 3 4 5 7 1014 20 30 50 70 100 200
I/In
Dimension(mm):
4P
3P
2P
1P
72
54
36
18
82
35
4576
www.meba.net
Miniature
Circuit Breaker
35
MB52
www.meba.net
Miniature
Circuit Breaker
MBB8-63-1P/2P
Miniature Circuit Breaker
MBB8-63-1P/ 2P mini circuit breaker
Function: overload and short-circuit protection
Poles: 1P, 2P, 3P, 4P
Current rate: 1-63A
The prod uct is mainly used in AC50/60HZ single-pole 230V or
two, three, four-pole 400V circuit for overload and short-circuit
protection as well as for unfrequenton-and-off switching electric
equipment and lightingcircuit under normal condition. The product
is suitable for industry, business, building, residence, etc. It is
conformity with GB10963, IEC60898 standards.
Applications:
Features:
Much higher short circuit breaking capacity.
Dual-connection convenient for both standard busbar and
conductor connection.
Improved safetyof operatorsofferedby specialdesign ofterminals.
Much longer service life thanks to energy storage operating
mechanism.
A variety of modular auxiliaries allows for easy and quick
installation.
Enclosure and functional parts made of advanced plastics with
flame-retardant, heat-resistant and impulse-proofproperti es.
Higher current-limiting capacity ensuring a cost-effective
range of products.
Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A,
40A, 50A, 63A.
Tripping characteristics: B(3-5)In; C(5-10)In; D(10-15)In.
No. of pole: 1p, 2p, 3p, 4p.
Breaking capacity (see table1).
Technical parameter:
Rated current
(A)
1~63
Pole
Rated Voltage
(V)
Rated short-circuit
breaking current (A)
1
2,3,4
230, 230/400
400
6000
6000
COS
0.7
0.7
MBB8-63-3P/4P
Miniature Circuit Breaker
MBB8-63-3P/4P mini circuit breaker
Function: overload and short-circuit protection
Poles: 1P, 2P, 3P, 4P
Current rate: 1-63A
The prod uct is mainly used in AC50/60HZ single-pole 230V or
two, three, four-pole 400V circuit for overload and short-circuit
protection as well as for unfrequenton-and-off switching electric
equipment and lightingcircuit under normal condition. The product
is suitable for industry, business, building, residence, etc. It is
conformity with GB10963, IEC60898 standards.
Applications:
Features:
Much higher short circuit breaking capacity.
Dual-connection convenient for both standard busbar and
conductor connection.
Improved safetyof operatorsoffered byspecial designof terminals.
Much longer service life thanks to energy storage operating
mechanism.
A variety of modular auxiliaries allows for easy and quick
installation.
Enclosure and functional parts made of advanced plastics with
flame-retardant, heat-resistant and impulse-proofproperti es.
Higher current-limiting capacity ensuring a cost-effective
range of products.
Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A,
40A, 50A, 63A.
Tripping characteristics: B(3-5)In; C(5-10)In; D(10-15)In.
No. of pole: 1p, 2p, 3p, 4p.
Breaking capacity (see table1).
Technical parameter:
Rated current
(A)
1~63
Pole
Rated Voltage
(V)
Rated short-circuit
breaking current (A)
1
2,3,4
230, 230/400
400
6000
6000
COS
0.7
0.7
36
MBB8-63-3P/4PMBB8-63-1P/2P
MBB47 Miniature Circuit Breaker
Features and Applications:
The product ismainly used inAC50/60HZ single-pole230Vor two, three, four-poles 400Vcircuitfor overload and short-cir cuit protectio n
as well as for unfrequent on-and-off switching electric equipment and lighting circuit under normal condition. It can be used in lighting
and electric motor distribution system. It is characterized with novel structure, light weight, reli able and excellent performance, high
breaking capacity. It is conformity with GB10963, IEC 60898 standards.
Specification needs:
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century, Year, Month and Batch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBB47
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35 mm
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10
times rated current ( TypeC ), 3 to 5 times rated current ( TypeB ), 10 to 14 times rated current ( Type D )
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the
trigger mechanism in the presence of an overload or short circuit.
CE CB
ISO 9001-2000 awardedby the competentcertification body, Mebais qualifiedin themanufacturing of theobject
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
The packaging is sure that withstand any adverse conditions duringtransport and handling to the warehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
A
Vac
Hz
kA
2
mm
A
93% RH at 25 50% RH at 40
-5 a 40
1/2/3/4/5/6/10/16/20/25/32/40/50/63
240/415
50/60
6
40
IP20
1/2/3/4
25
4000
8000
B/C/D
Type B: 3 a 5 In Type C: 5 a 10 In Type D: 10 a 14 In
attach
www.meba.net
Miniature
Circuit Breaker
37
MBB47
MBB100 Miniature Circuit Breaker
Specification needs:
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
Operation Indicator Window
A
Vac
Hz
kA
2
mm
A
93% RH at 25
10 a 60
63/80/100
240/415
50/60
10
40
IP20
1,2,3,4
63A/16 80A/25 100A/35
4000
8000
C/D
Type C 5 a 1 0 In Type D 10 a 14 I n
attach
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBB100
IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230 V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35 mm
The circuit breaker have an operating window color display that shows the state in which it is (connected
or disconnected ).
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10
times rated current ( TypeC ), 10 to 14 times rated current ( Type D)
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the
trigger mechanism in the presence of an overload or short circuit.
CE CB
ISO9001-2000 awardedby the competent certificationbody,Meba isqualifiedinthemanufacturing ofthe object
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
The packaging issure that withstandany adverse conditions during transportand handling to the warehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
Miniature
Circuit Breaker
www.meba.net
38
MBB100
Dimension(mm):
27
35
7.5
108
81
54
27
67
60
5
81
36
45
44
The over-current protection property:
Ambient
Temperature
40 2
-5~+40
Initial Status Test Current Expected Result Expected Result NOte
Cold position
Cold position
Cold position
Cold position
1.05In(In 63A)
1.05In (In 63A)
1.30In(In 63A)
1.30In (In>63A)
8.00In
12.00In
t 1h
t 2h
t < 1h
t < 2h
t 0.2s
t< 0.2s
Non-release
Non-release
Release
Release
Non-release
Non-release
-
-
-
-
Carried out immedi-ately
after previous test
Current smoothlyrises to
specified value within 5s
MBB100 Miniature Circuit Breaker
NC100H-1P Miniature Circuit Breaker
Features and Applications:
Character: high breaker capacity up to 10KA
40-100A current avaliable
Poles: 1P, 2P, 3P, 4P.
NC100H mini circuit breaker, mcb
NC100H high breakingcapacity circuit breaker is usedfor AC50Hz
or 60Hz, single pole 240V, 2, 3, 4 Poles 415, for protecting the
circuit that overload and short circuit may take place. It can be
used in lighting and electricmotor distribution system.Meanwhile
it is applicableto an unfrequentswitchover the electric apparatus
and lighting circuit under normal condition. Breaking capacity is
up to standard of IEC947-7 10KA.
Technical parameter:
Rated current
(A)
Pole number
(P)
Rated voltage
(V)
Breaking capacity
(A)
40, 50, 63, 80, 100
1
2, 3, 4
130
230/240
400/415
230/240
400/415
440
20000
10000
4000
20000
10000
6000
www.meba.net
Miniature
Circuit Breaker
39
MBB100 NC100H-1P
NC100H-2P Miniature Circuit Breaker
Features and Applications:
NC100H high breaking capaci ty circuit breaker is used for AC 50Hz or 60Hz, single pole 240V, 2, 3, 4 Poles 415, for protecting the
circuit that overload and short circuit may take place. It can be used in lighting and electric motor distribution system. Meanwhile it
is applicable to an unfrequent switchover the electric apparatus and lighting circuit under normal condition. Breaking capacity is up
to standard of IEC947-7 10KA.
Character: high breaker capacity up to 10KA
40-100A current avaliable
Poles: 1P, 2P, 3P, 4P.
NC100H mini circuit breaker, mcb
Technical parameter:
Rated current (A) Pole number (P) Rated voltage (V) Breaking capacity (A)
40, 50, 63, 80, 100
1
2, 3, 4
130
230/240
400/415
230/240
400/415
440
20000
10000
4000
20000
10000
6000
NC100H-3P Miniature Circuit Breaker
Features and Applications:
NC100H high breaking capaci ty circuit breaker is used for AC 50Hz or 60Hz, single pole 240V, 2, 3, 4 Poles 415, for protecting the
circuit that overload and short circuit may take place. It can be used in lighting and electric motor distribution system. Meanwhile it
is applicable to an unfrequent switchover the electric apparatus and lighting circuit under normal condition. Breaking capacity is up
to standard of IEC947-7 10KA.
Character: high breaker capacity up to 10KA
40-100A current avaliable
Poles: 1P, 2P, 3P, 4P.
NC100H mini circuit breaker, mcb
Technical parameter:
Rated current (A) Pole number (P) Rated voltage (V) Breaking capacity (A)
40, 50, 63, 80, 100
1
2, 3, 4
130
230/240
400/415
230/240
400/415
440
20000
10000
4000
20000
10000
6000
www.meba.net
Miniature
Circuit Breaker
40
NC100H-3PNC100H-2P
Specification needs:
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
A
Vac
Hz
kA
2
mm
A
MBGV4 Miniature Circuit Breaker
www.meba.net
Miniature
Circuit Breaker
93% RH at 25 50% RH at 40
-5 a 40
6/10/16/20/25/32/40/50/63
240/415
50/60
6
-5 a 40
IP20
1/2/3/4
25
4000
8000
B/C/D
Type B: 3 a 5 In Type C: 5 a10 In Type D: 10 a 14 In
attach
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBGV4
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35 mm
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10
times rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 14 times rated current ( Type D )
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the
trigger mechanism in the presence of an overload or short circuit.
CE CB
ISO9001-2000 awardedby thecompetentcertification body,Meba isqualifiedin themanufacturing oftheobject
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
The packaging is surethat withstandany adverse conditions duringtransport and handlingto thewarehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
41
MBGV4
A
Vac
Hz
kA
2
mm
A
MBH6 Miniature Circuit Breaker
Protectio n and control of circuit against overload andshort circuit, inbuilding installation-such ashouses, offices, commerci al complex,
motor system (D curve) and industrial installation-for switching,control,protection and regulationof electrical circuits. Also in switchgear
panels, railway and marine application.
Applications:
Specification needs:
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century, Year, Month and Batch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
93% RH at 25 50% RH at 40
-5 a 40
6/10/16/20/25/32/40/50/63
240/415
50/60
6
-5 a 40
IP20
1/2/3/4
25
4000
8000
B/C/D
Type B: 3 a 5 In Type C: 5 a 10 In Type D: 10 a 14 In
attach
Miniature
Circuit Breaker
www.meba.net
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBH6
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35mm
MAGNETIC COIL:ensures the switching of short-circuit, speaking withinthe following ranges: 5to 10 times
rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 14 times rated current ( TypeD )
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectively dissipates theelectric arc that is generatedby the opening contacts of thetrigger
mechanism in the presence of an overload or short circuit.
CE CB
ISO 9001-2000awarded by thecompetent certification body, Meba isqualified in themanufactu ring of the object
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receivingthe circuit breakers (breakers) , customers may perform the tests may be necessary toensure
compliance with the technical specifications.
The packaging issure that withstand any advers e conditions during transport and handling to the warehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
42
MBH6
A
Vac
Hz
kA
2
mm
A
MBHVS-3D Isolator
Specification needs:
Applications:
Capable of switch electric circuit with load
Provide function of isolation
Contact position indication
Used as main switch for household and simiar installation
Electrical Properties
Type of Assembly
Present Certificates
Testing For Acceptance
Packing
DialCentury,Year, Monthand Batch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBHVS Isolator
IEC 60947-3
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35mm
CE
ISO 9001-2000
IEC 60947-3 standards
Life, given by us to ensure that the life of the goods offered by atleast 5 years.
Before receiving the circuit breakers (breakers ), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
We are surethe packaging withstand any adverse conditions during transport and handling to the cellars
of the Company. Carton or Pallet
In one of its sides the breaker is marked with the symbol permanent ink, year, month and batch.
available
Submit sample of the product offered
2 YEARS
CIF CNF FOB
25 Days
93% RH at 25
-5 a 40
6/16/20/25/32/40/50/63/80/100
240/415
50/60
4.5/6
-5 a 40
IP20
1/2/3/4
25
4000
8000
/
/
attach
www.meba.net
Miniature
Circuit Breaker
43
MBHVS-3D
MBHVS Isolator
Specification needs:
A
Vac
Hz
kA
2
mm
A
Electrical Properties
Type of Assembly
Present Certificates
Testing For Acceptance
Packing
DialCentury,Year, Monthand Batch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
93% RH at 25
-5 a 40
6/16/20/25/32/40/50/63/80/100
240/415
50/60
4.5/6
-5 a 40
IP20
1/2/3/4
25
4000
8000
/
/
attach
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBHVS Isolator
IEC 60947-3
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35mm
CE
ISO 9001-2000
IEC 60947-3 standards
Life, given by us to ensure that the life of the goods offered by atleast 5 years.
Before receiving the circuit breakers (breakers ), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
We are surethe packaging withstand any adverse conditions during transport and handling to the cellars
of the Company. Carton or Pallet
In one of its sides the breaker is marked with the symbol permanent ink, year, month and batch.
available
Submit sample of the product offered
2 YEARS
CIF CNF FOB
25 Days
Miniature
Circuit Breaker
www.meba.net
44
MBHVS Isolator
www.meba.net
Applications:
MBHVS Isolator
Capable of switch electric circuit with load
Provide function of isolation
Contact position indication
Used as main switch for household and simiar installation
Overall & Installation Dimensions:
18
36
54
72
MBHVS Miniature Circuit Breaker
Protection and control of circuitagainst overload and short circuit,
in building installation-such as houses, offices, commercial
complex, motor system(D curve) and industrial installation-for
switching, control, protectionand regulation ofelectrical cir cuits.
Also in switchgear panels, railway and marine application.
Applications:
86
36
45
67
Overall & Installation Dimensions:
17
34
51
68
82.5
37
47
66
76
45
Miniature
Circuit Breaker
45
MBHVSMBHVS Isolator
www.meba.net
MBHVS Miniature Circuit Breaker
Specification needs:
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Product Details
Manufacturing Standards
Tropicalization
A
Vac
Hz
kA
2
mm
A
Miniature
Circuit Breaker
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBHVS
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35mm
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10
times rated current (Type C), 3 to 5 times rated current (Type B), 10 to 14 times rated current (Type D )
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the
trigger mechanism in the presence of an overload or short circuit.
CE
ISO 9001-2000awarded by thecompetent certificati on body, Mebais qualified in the manufacturing ofthe object
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
The packaging is sure that withstand any adverse conditionsduring transport andhandlingto the warehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
93% RH at 25 50% RH at 40
-5 a 40
6/10/16/20/25/32/40/50/63
240/415
50/60
6
-5 a 40
IP20
1/2/3/4
25
4000
8000
B/C/D
Type B: 3 a 5 In Type C: 5 a10 In Type D: 10 a 14 In
attach
46
MBHVS
www.meba.net
Miniature
Circuit Breaker
MB162-1P/3P Isolator Miniature Circuit Breaker
Specification needs:
A
Vac
Hz
kA
2
mm
A
Electrical Properties
Type of Assembly
Present Certificates
Testing For Acceptance
Packing
DialCentury,Year, Monthand Batch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
93% RH at 25
-5 a 40
63/80/100/125
240/415
50/60
3
-5 a 40
IP20
1/2/3/4
25
4000
8000
/
/
attach
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MB162
IEC 60947-3
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35mm
CE
ISO 9001-2000
IEC 60947-3 standards
Life, given by us to ensure that the life of the goods offered by atleast 5 years.
Before receiving the circuit breakers (breakers), customers may performthe tests may be necessary to
ensure compliance with the technical specifications.
We are surethe packaging withstand any adverse conditions during transport and handling to the cellars
of the Company. Carton or Pallet
In one of its sides the breaker is marked with the symbol permanent ink, year, month and batch.
available
Submit sample of the product offered
2 YEARS
CIF CNF FOB
25 Days
47
MB162-1P MB162-3P
MBDR047 Delay Relay
Miniature
Circuit Breaker
www.meba.net
MB162-1P/3P Isolator
Miniature Circuit Breaker
Applications:
MB162 is major used as main switch in distribution box, control
on or off for all branch switch. The product is applicable to circuit
with rated voltage 230/400V AC, 50Hz for power distribution and
motor operation as switching disconnector in both household &
commercial and electric equipments installations. The product,
free of maintenance,is suitable for use bynon-professionals. The
product is switched on when the handle is at upper position.
Overall and mounting dimensioned chart:
86
36
45
66
18
36
54
72
Application:
MBDR047 is one kind of timer relay, used in distribution box with
MCB, Isolator, Surge Arrester together.
Rated voltage(V): 220-415.
Overall & Installation Dimensions:
45.5
35
95
44.5
63.56
18
48
MBDR047MB162-1P/3P
MBDPE06 Miniature Circuit Breaker
Specification needs:
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
Operation Indicator Window
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBDPE
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230 V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve C
Characteristic Intervention
FOR RIEL DIN 35 mm
The circuit breaker have an operating window color display that shows the state in which it is ( connected
or disconnected ).
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10
times rated current ( Type C ), 3 to 5 times rated current (Type B ), 10 to 14 times rated current ( Type D )
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the
trigger mechanism in the presence of an overload or short circuit.
CE CB
ISO9001-2000awarded bythe competentcertification body, Meba is qualified in themanufacturingof theobject
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
The packaging is sure that withstandany adverse conditionsduring transport and handling to thewarehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
93% RH at 25
10 a 60
1/2/3/4/6/10/16/20/25/32/40/50/63
240/415
50/60
6
-5 a 40
IP20
1/2/3/4
25
4000
10000
B/C/D
5 a 10 In
attach
A
Vac
Hz
kA
2
mm
A
www.meba.net
Miniature
Circuit Breaker
49
MBDPE06
MBJ6 Miniature Circuit Breaker
Applications:
Specification needs:
www.meba.net
Miniature
Circuit Breaker
A
Vac
Hz
kA
2
mm
A
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century, Year, Month and Batch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
93% RH at 25 50% RH at 40
-5 a 40
6/10/16/20/25/32/40/50/63
240/415
50/60
6
-5 a 40
IP20
1/2/3/4
25
4000
8000
B/C/D
Type B: 3 a 5 In Type C: 5 a 10 In Type D: 10 a 14 In
attach
Protectio n and control of circuit against overload and short circuit, in buildinginstallation-such as houses,offices, commercial complex,
motor system(D curve)and industrial installation-forswitching, control, protectionand regulation ofelectrical circuits.Also in switchgear
panels, railway and marine application.
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBJ6
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35mm
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times
rated current ( Type C), 3 to 5 times rated current ( Type B ), 10 to 14 times rated current ( TypeD )
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electricarc that isgenerated by the opening contacts ofthe trigger
mechanism in the presence of an overload or short circuit.
CE CB
ISO9001-2000 awarded by the competentcertificat ion body, Mebais qualified inthe manufacturingof theobject
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving thecircuit breakers (breakers),customers may performthe tests maybe necessary toensure
compliance with the technical specifications.
The packaging is sure that withstand any adverse conditions during transport and handlingto the warehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
50
MBJ6
Specification needs:
A
Vac
Hz
kA
2
mm
A
Product Details
Manufacturing Standards
Tropicalization
Electrical Properties
Type of Assembly
Operation Indicator Window
Present Certificates
Testing For Acceptance
Packing
Dial Century, Year, Month and Batch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBL7 Insulator
IEC 60947-3
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35 mm
The circuit breaker have an operating window color display that shows the state in which it is (connected or
disconnected).
CE
ISO 9001-2000
IEC 60947-3 standards
Life, given by us to ensure that the life of the goods offered by atleast 5 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
We are surethe packaging withstand any adverse conditions during transport and handling to the cellars of
the Company.Carton or Pallet.
In one of its sides the breaker is marked with the symbol permanent ink, year, month and batch.
Available
Submit sample of the product offered
2 YEARS
CIF CNF FOB
25 Days
93% RH at 25
-5 a 40
6/16/20/25/32/40/50/63/80/100
240/415
50/60
3/4.5
-5 a 40
IP20
1/2/3/4
25
4000
8000
/
/
attach
Applications:
MBL7 Insulator
Capable of switch electric circuit with load
Provide function of isolation.
Contact position indication.
Used as main switch for household and simiar installation.
www.meba.net
Miniature
Circuit Breaker
51
MBL7
5.5
35 45
44
60
76.5
80
17.5
MBL7 DPN
MBL7 Series Miniature Circuit Breaker (hereinaft er referred to
as breaker) is the company's own research and development
of new products, theproducts arereliableand accurate protection
features, high breaking capacity, smallsize, isan ideal replacement
product. Circuit breaker is mainly applied to 50Hz/60HZ , rated
voltage 230V, rated operating current to 40 A similar buildings and
places of powerlines and electrical fac ili tie s, over-current protection
devices, can beused for non-frequent on-off operati on. The circuit
breaker in line with IEC60898: 1995, GBl0963-1999 "category for
household and Currentprotection may place used circuitbreakers"
and other standards.
Applications:
Shape and size of the installation of technology:
Trip Type
Thermal Trip
Magnetic Trip
B
1.13In
1.45In
3In
5In
C
1.13In
1.45In
3In
10In
Trip Time
1h
<1h
0.1s
<0.1s
I1
I2
I3
I4
MBL7 Indicator
Din Rail type LED Indicator, Neon Signal Lamp
Specification:
Low service duration, minimum power consumption
Compact design in modular size, easy installation
Rated voltage: 230V AC, 50/60Hz
Colour: Red, green, yellow
Connection terminal: Pillar terminalwith clamp
2
Connection capacity: Rigid conductor10mm
Installation: - On symmetrical DIN rail
- Panel mounting
Illumination type:
A. Illumination: LED
- Max power: 0.6W
- Service duration: 30,000 hours
B. Illumination: Neon bulb
- Max power: 1.2W
- Service duration: 15,000 hours
The DIN Rail type Modular Signal Lamp is applicable to circuit with
rated voltage 230V AC, 50/60Hz for visual indication and signaling.
Overall & Installation Dimensions:
18 44.6
26.35.5
91
35
45.5
70.5
Miniature
Circuit Breaker
www.meba.net
52
MBL7 DPNMBL7
Specification needs:
MBL7 DPN
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
Operation Indicator Window
A
Vac
Hz
kA
2
mm
A
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBL7
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve C
Characteristic Intervention
FOR RIEL DIN 35mm
The circuit breaker have an operating window color display that shows the state in which it is (connected
or disconnected).
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 3 to 10
times rated current ( Type C ), 3 to 5 times rated current (Type B), 10 to 14 times rated current ( Type D)
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the
trigger mechanism in the presence of an overload or short circuit.
CE CB
ISO 9001-2000 awarded bythe competent certification body, Meba isqualified in the manufacturing of the object
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
The packaging issure that withstand any adverse conditions during transport and handling to the warehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
93% RH at 25
10 a 60
6/10/16/20/25/32/40
240/415
50/60
6
-5 a 40
IP20
1P+N
25
4000
8000
B/C
3 a 10 In
attach
www.meba.net
Miniature
Circuit Breaker
53
MBL7 DPN
www.meba.net
Miniature
Circuit Breaker
C characteristic curve
Trip current(X ln)
Trip
time
100
10
1
10
1
0.1
0.01
1 2 3 4 6 8 10 20
C
MBL7 DPN
Structural characteristics:
Small size, limiting the effect of good, high breaking capacity,
with 1P+N double break point, the polarization was Insulation
to isolate, insync and connectedto the premise of breaking, N
always first toconnect, after breakingboth to ensurethe protection
of polar arcbreakingthe abilityto effectively protectand control
lines and electrical equipment safety.
Obvious conta ct with the locationof the stateof the instructions.
-Type terminal block used to enhance, to facil ita te wir ing to
2 2
ensure that the wire 1mm to 16mm reliable connection.
C characteristic curve
Trip current(X ln)
Trip
time
100
10
1
10
1
0.1
0.01
1 2 3 4 6 8 10 20
C
Normal working conditions and installation conditions:
The normal working conditions:
shall not exceed the limit of air temperature, the lower limit of
+40 not below -5 , 24h+35 than average
The location of the altitude than 2000mm.
The location ofthe air relative humidity in the highesttemperature
around 40 when does not exceed 50%, at lower temperatures
can allow higherrelative humidity. The wetmonths mean maximum
relative humidity,and nomore than 90 percent of the average
minimum temperature does not exceed +25 . Andconsidering
the temperature changes in product on the surface of the
condensation.
Pollution level 2.
Installation conditions:
Installation category two, three type.
Breaker using standard guide installation.
Circuit breaker should normally be mounted vertically, the
handle up for access to current location.
Installation should be no significant shock and vibration.
Load capacity:
Load Factor K
Switch number(n) MCB capacity
1.10
1.00
0.90
0.80
0.70
1 2 3 4 5 6 7 8
Load Factor (I/In)
Temperature( )Temperature of
1.50
1.40
1.30
1.20
1.10
1.00
0.90
-30 -20 -10 0 10 20 30 40 50 60
JAB7-40 and DO fuse or short-circuit the performance of NH
1.4 high selectivity of 1.4 KA, No functional
1.On electrical circuits
from overload and short
circuit protection.
2.Especially suitable for
civilian use with a bracket
of the lighting circuit
protection.The centerline
breaking, more secure.
Rated Current (A) In
2
4
6
10
16
20
25
32
40
Model
54
MBL7 DPN
MBL7 DPN
Orders should be indicated when the product model, release type, the number of such.
For example: JAB7-40 mini circuit breaker, rated current of 16A, release patterns for the C-type, 100 units, is expressed as
JAB7-40-C16.
Order Information:
JAB7-40 of the rated current
Characteristic curve of C
GL fuse rated current (A)
10 16
<0.5
20
0.7
25
1.1
0.8
35
2.1
1.5
1.4
1.4
1.2
50
3.4
3.1
2.9
2.4
2.0
63
5.0
4.6
4.1
3.4
2.9
2.3
80
6.0
5.5
4.5
3.8
3.0
2.4
100
6
10
13
16
20
25
32
40
Fuse D01, D02, D03 performance:
NH-00 fuse option:
JAB7-40 of the rated current
Characteristic curve of C
GL fuse rated current (A)
6
10
13
16
20
25
32
40
16
<0.5
20
0.5
25
0.8
0.7
35
2.7
1.8
1.6
1.5
1.3
40
4.0
2.3
2.1
1.9
2.0
50
3.1
3.1
2.8
2.3
2.0
63
4.6
4.1
3.9
3.1
2.7
2.1
80
6.0
5.5
5.0
4.2
3.5
2.9
2.4
100 125 160
Overall & Installation Dimensions:
18
36
54
72
80
36
50
66
76
45
MBL8/MBL9 Miniature Circuit Breaker
www.meba.net
Miniature
Circuit Breaker
55
MBL8MBL7 DPN
Miniature
Circuit Breaker
www.meba.net
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century,Year, Month andBatch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
Operation Indicator Window
A
Vac
Hz
kA
2
mm
A
Manufacturer: Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBL8/ MBL9
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve C
Characteristic Intervention
FOR RIEL DIN 35mm
The circuit breaker have an operating window color display that shows the state in which it is (connected
or disconnected).
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10
times rated current (Type C), 3 to 5 times rated current ( TypeB ), 10 to 14 times rated current ( Type D)
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the
trigger mechanism in the presence of an overload or short circuit.
CE
ISO 9001-2000 awardedby thecompetent certific atio n body, Meba is qualified in the manufact uring of the objec t
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to
ensure compliance with the technical specifications.
The packaging issure that withstand any adverse conditions during transport and handlingto the warehouse
of customers
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
93% RH at 25
-5 a 40
6/10/16/20/25/32/40/50/63
240/415
50/60
6
-5 a 40
IP20
1/2/3/4
25
6000
20000
B/C/D
5 a 10 In
attach
Specification needs:
MBL8/MBL9 Miniature Circuit Breaker
56
MBL9MBL8
www.meba.net
Miniature
Circuit Breaker
MBLPN/MBLPN2 Miniature Circuit Breaker
Application:
Protection and control of circuit against overload and short circuit, in building installation-such as houses, offices, commercial complex,
motor system(D curve) and industrial installation-for switching, control, protection and regulation of electrical circuits. Also in switchgear
panels, railway and marine application.
Applicable to terminal and pin/fork type busbar connection Protection against both overload and short circuit
High short-circuit capacity
Specification needs:
A
Vac
Hz
kA
2
mm
A
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century, Year, Month and Batch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
Manufacturer Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBLPN/ MBLPN2
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230 V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35 mm
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times
rated current (Type C), 3 to 5 times rated current ( Type B), 10 to 14 times rated current ( Type D )
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectively dissipates the electric arc that isgenerated by theopening contacts of thetrigger
mechanism in the presence of an overload or short circuit.
CE CB
ISO 9001-2000awarded by thecompetent certification body, Meba is qualified in the manufacturing ofthe object
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving thecircuit breakers (breakers), customers may perform thetests may benecessary to ensure
compliance with the technical specifications.
The packaging issure that withstandany adverse conditions during transpo rt and handling to the warehouse
of customers.
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
93% RH at 25 50% RH at 40
-5 a 40
6/10/16/20/25/32/40/50/63
240/415
50/60
6
40
IP20
1/2/3/4
25
4000
8000
B/C/D
Type B: 3 a 5 In Type C: 5 a 10 In Type D: 10 a 14 In
attach
57
MBLPN MBLPN2
Miniature
Circuit Breaker
www.meba.net
Application:
Protection and control of circuit against overload and short circuit, in building installation-such as houses, offices, commercial complex,
motor system(D curve) and industrial installation-for switching, control, protection and regulation of electrical circuits. Also in switchgear
panels, railway and marine application.
Applicable to terminal and pin/fork type busbar connection Protection against both overload and short circuit
High short-circuit capacity
Specification needs:
A
Vac
Hz
kA
2
mm
A
Electrical Properties
Type of Assembly
Features
Present Certificates
Testing For Acceptance
Packing
Dial Century, Year, Month and Batch
Catalog
Shows
Technical Warranty
Place of Delivery
Delivery
Product Details
Manufacturing Standards
Tropicalization
Manufacturer Meba Electric Enterprises
Country of Origin: China
Brand: Meba
Model: MBLSN/ MBLSN2
IEC 60898 IEC60947
Relative Humidity
Room Temperature
Rated at 40
Rated operating voltage at 40
Nominal Frequency
Interrupting Capacity at 230 V
Operating temperature
Degree of Protection
Number of poles
Conductor cross section (minimum allowable)
Minimum number of power moves
Minimum number of mechanical operations
Operation curve
Current Trip Curve
Characteristic Intervention
FOR RIEL DIN 35 mm
MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times
rated current (Type C), 3 to 5 times rated current ( Type B), 10 to 14 times rated current ( Type D )
BIMETAL: ensuresthe breaker trip when overloaded.
ARC CHAMBER: effectively dissipates the electric arc that isgenerated by theopening contacts of the trigger
mechanism in the presence of an overload or short circuit.
CE CB
ISO9001-2000awarded by thecompetent certification body, Meba is qualified in the manufacturing ofthe object
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect
Life, given by Meba to ensure that the life of the goods offered by atleast 15 years.
Before receiving the circuit breakers (breakers), customersmay performthe tests maybe necessary toensure
compliance with the technical specifications.
The packaging issure that withstandany adverse conditions during transp ort and handling to the warehouse
of customers.
In one of its sides the breaker is marked with permanent ink, year, month and batch.
Attach catalogs indicating the technical specification
Submit sample of the product offered
2 YEARS
FOB & CNF
25 Days
MBLSN/MBLSN2 Miniature Circuit Breaker
93% RH at 25 50% RH at 40
-5 a 40
6/10/16/20/25/32/40/50/63
240/415
50/60
6
40
IP20
1/2/3/4
25
6000
20000
B/C/D
Type B: 3 a 5 In Type C: 5 a 10 In Type D: 10 a 14 In
attach
58
MBLSN2MBLSN
www.meba.net
Miniature
Circuit Breaker
Specifications: Technical parameter:
Max. AC Voltage
Max. Interrupting Capacity
Min. Current Rating
Max. Current Rating
Agency Recognition of Approvals
Branch circuit protection
Telecom power distribution
Power conditioning
Automatic control systems
Power supplies
Applications:
Power conversion systems
UPS equipment
Control machines
Generator sets
MBQH1/MBQH2 Miniature Circuit Breaker
Hydraulic-magnetic technology ensures reduced nuisance
tripping with temperature variance
Always hold 100% rated current
Wide range of time delays & operating currents
Current limiting capabilities
Ultra compact 26mm width module
Din (13), (18) only, Mini-rail orDual mountable (13),(19) and(26)
Trip indication with mid trip handle position
Switch disconnector provides circuit isolation
Reset possible immediately after overload
230/400 VAC
10kA rms
10A
1=125A
2, 3,1+N, 3+N=100A
IEC 60947-2
SANS VC8036
SANS 156
Poles
1
2
3
1+N
3+N
Voltage
230VAC
400VAC
400VAC
230VAC
400VAC
KA
10
10
10
10
10
MCB Width(mm)
26 (1 Module)
52 (2 Module)
78 (3 Module)
52 (2 Module)
104 (4 Module)
STD Pack
12
6
4
6
3
Rating(A)
10 15 20 25 30 35 40 45 50 63 70 80 100 125
10 15 20 25 30 35 40 45 50 63 70 80 100
10 15 20 25 30 35 40 45 50 63 70 80 100
10 15 20 25 30 35 40 45 50 63 70 80 100
10 15 20 25 30 35 40 45 50 63 70 80 100
Poles
1
3
Voltage
230VAC
400VAC
KA
10
10
MCB Width(mm)
26 (1 Module)
78 (3 Module)
STD Pack
12
4
Rating(A)
10 15 20 25 30 35 40 45 50 63 70 80 100 125
10 15 20 25 30 35 40 45 50 63 70 80 100
Poles
1
2
3
Voltage
230VAC
400VAC
400VAC
KA
10
10
10
MCB Width(mm)
26 (1 Module)
52 (2 Module)
78 (3 Module)
STD Pack
12
6
4
Rating(A)
63 125
63 100
63 100
QH Range
Standard Circuit Breaker 10KA Curve 2 (Standard) mini and DIN Mounting, 57 MM Escutcheon
Type
QH-1(26)
QH-2(26)
QH-3(26)
QH-N-2(26)
QF-N-4(26)
Standard Circuit Breaker 10KA Curve 1, mini and DIN Mounting, 57 MM Escutcheon
Type
QH-1(26)
QH-3(26)
Standard Circuit Breaker 10KA Curve 1, mini and DIN Mounting, 57 MM Escutcheon
Type
QH-S-1(26)
QH-S-2(26)
QH-S-3(26)
59
MBQH1 MBQH2
Specifications:
Hydraulic-magnetic technology ensures reduced nuisance
tripping with temperature variance
Always hold 100% rated current
Wide range of time delays & operating currents
Current limiting capabilities
Ultra compact 13, 18, 19, 26mm width module
Din (13), (18) only,Mini-rail or Dual mountable(13), (19)and (26)
Trip indication with mid trip handle position
Switch disconnector provides circuit isolation
Reset possible immediately after overload
Technical parameter:
Max. AC Voltage
Max. Interrupting Capacity
Min. Current Rating
230/400 VAC
5kA rms
0.5A
1=125A
3=100A
IEC 60947-2
SANS VC8036
SANS 156
Max. Current Rating
Agency Recognition of Approvals
MBQF-D Miniature Circuit Breaker
Branch circuit protection
Telecom power distribution
Power conditioning
Automatic control systems
Power supplies
Applications:
Power conversion systems
UPS equipment
Control machines
Generator sets
QF Range
Special Supply Authority/Industrial Circuit Breaker-5KA
Type
QF-1(13)
QF-3(13)
QF-1(19)
QF-3(19)
QF-1(26)
QF-3(26)
Switch Disconnectors 6KA, mini and DIN Rail Mounting, 45 mm Escutcheon
Type
QF-1(13)-D
QF-3(13)-D
QF-1(18)-D
QF-3(18)-D
QF-1(26)-D
QF-3(26)-D
Poles
1
3
1
3
1
3
Voltage
230VAC
400VAC
230VAC
400VAC
230VAC
400VAC
KA
5
5
5
5
5
5
MCB Width(mm)
13 (1 Module)
39 (3 Module)
19.5 (1 Module)
58.5 (3 Module)
26 (2 Module)
78 (3 Module)
STD Pack
12
4
12
4
12
4
Rating(A)
10 15 20 25
10 15 20 25
10 15 20 25 30 35 40 45 50 63
10 15 20 25 30 35 40 45 50 63
10 15 20 25 32 40 45 50 63 70 80 100 125
10 15 20 25 32 40 45 50 63 70 80 100
Poles
1
3
1
3
1
3
Voltage
230VAC
415VAC
240VAC
415VAC
240VAC
415VAC
KA
6
6
6
6
5
5
MCB Width(mm)
13 (1 Module)
39 (3 Module)
18 (1 Module)
54 (3 Module)
26 (2 Module)
78 (3 Module)
STD Pack
12
4
12
4
12
4
Rating(A)
10 15 20 25
10 15 20 25
10 15 20 25 30 35 40 45 50 63
10 15 20 25 30 35 40 45 50 63
10 15 20 25 32 40 45 50 63 70 80 100 125
10 15 20 25 32 40 45 50 63 70 80 100
www.meba.net
Miniature
Circuit Breaker
60
MBQF-D
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba
1.MCB -Meba

More Related Content

What's hot

Htr india-products-current-sense-resistors-electron-beam-welded-heb-english
Htr india-products-current-sense-resistors-electron-beam-welded-heb-englishHtr india-products-current-sense-resistors-electron-beam-welded-heb-english
Htr india-products-current-sense-resistors-electron-beam-welded-heb-english
htrindia
 
Htr india-products-current-sense-resistors-electron-beam-welded-heb-english
Htr india-products-current-sense-resistors-electron-beam-welded-heb-englishHtr india-products-current-sense-resistors-electron-beam-welded-heb-english
Htr india-products-current-sense-resistors-electron-beam-welded-heb-english
htrindia
 
ABB Medium Voltage MV Surge Arresters - AC & DC Surge Arresters & Protection...
ABB Medium Voltage MV Surge Arresters -  AC & DC Surge Arresters & Protection...ABB Medium Voltage MV Surge Arresters -  AC & DC Surge Arresters & Protection...
ABB Medium Voltage MV Surge Arresters - AC & DC Surge Arresters & Protection...
Thorne & Derrick International
 
Advances in Ceramic Capacitors
Advances in Ceramic CapacitorsAdvances in Ceramic Capacitors
Advances in Ceramic Capacitors
KEMET Electronics Corporation
 
1 reliability qualification report pcb
1 reliability qualification report pcb1 reliability qualification report pcb
1 reliability qualification report pcb
vasant7861
 
T540 and t541 new features
T540 and t541 new featuresT540 and t541 new features
T540 and t541 new features
KEMET Electronics Corporation
 
Htr india-products-wire-wound-resistors-silicone-coated-resistors-hia-english...
Htr india-products-wire-wound-resistors-silicone-coated-resistors-hia-english...Htr india-products-wire-wound-resistors-silicone-coated-resistors-hia-english...
Htr india-products-wire-wound-resistors-silicone-coated-resistors-hia-english...
htrindia
 
SEBA KMT Cable Fault Locators, Surge Generators (Thumpers) - SEBA KMT Cable F...
SEBA KMT Cable Fault Locators, Surge Generators (Thumpers) - SEBA KMT Cable F...SEBA KMT Cable Fault Locators, Surge Generators (Thumpers) - SEBA KMT Cable F...
SEBA KMT Cable Fault Locators, Surge Generators (Thumpers) - SEBA KMT Cable F...
Thorne & Derrick International
 
Technical specification for 3.ph 4 wire stw 12 02-11
Technical specification for 3.ph 4 wire stw 12 02-11Technical specification for 3.ph 4 wire stw 12 02-11
Technical specification for 3.ph 4 wire stw 12 02-11
laxman prasad
 
Htr india-products-current-sense-resistors-electron-beam-welded-heb-english
Htr india-products-current-sense-resistors-electron-beam-welded-heb-englishHtr india-products-current-sense-resistors-electron-beam-welded-heb-english
Htr india-products-current-sense-resistors-electron-beam-welded-heb-english
htrindia
 
Sar07030 series 2016
Sar07030 series 2016Sar07030 series 2016
Sar07030 series 2016
HT-TECH CORPORATION
 
Newson Gale Bond Rite Clamp
Newson Gale Bond Rite ClampNewson Gale Bond Rite Clamp
Newson Gale Bond Rite Clamp
https://newson-gale.com/
 
Abb low voltage lv capacitors, abb clmd
Abb low voltage lv capacitors, abb clmd  Abb low voltage lv capacitors, abb clmd
Abb low voltage lv capacitors, abb clmd
Thorne & Derrick International
 
Uniohm resistors datasheet for car -anti-sulfurized thick film chip resistors...
Uniohm resistors datasheet for car -anti-sulfurized thick film chip resistors...Uniohm resistors datasheet for car -anti-sulfurized thick film chip resistors...
Uniohm resistors datasheet for car -anti-sulfurized thick film chip resistors...
Felix Law
 
ABB POLIM-C..LB Medium Voltage Surge Arresters AC up to 5kV - AC Surge Arrest...
ABB POLIM-C..LB Medium Voltage Surge Arresters AC up to 5kV - AC Surge Arrest...ABB POLIM-C..LB Medium Voltage Surge Arresters AC up to 5kV - AC Surge Arrest...
ABB POLIM-C..LB Medium Voltage Surge Arresters AC up to 5kV - AC Surge Arrest...
Thorne & Derrick International
 
Data Teknis Gossen Metrawatt Insulation Tester METRISO INTRO-METRISO BASE-MET...
Data Teknis Gossen Metrawatt Insulation Tester METRISO INTRO-METRISO BASE-MET...Data Teknis Gossen Metrawatt Insulation Tester METRISO INTRO-METRISO BASE-MET...
Data Teknis Gossen Metrawatt Insulation Tester METRISO INTRO-METRISO BASE-MET...
PT. Siwali Swantika
 
ABB POLIM-C..N High Voltage Surge Arresters AC up to 7.5 kV - AC Surge Arrest...
ABB POLIM-C..N High Voltage Surge Arresters AC up to 7.5 kV - AC Surge Arrest...ABB POLIM-C..N High Voltage Surge Arresters AC up to 7.5 kV - AC Surge Arrest...
ABB POLIM-C..N High Voltage Surge Arresters AC up to 7.5 kV - AC Surge Arrest...
Thorne & Derrick International
 
Ceramic Safety Capacitors - Avoiding the Confusion
Ceramic Safety Capacitors - Avoiding the ConfusionCeramic Safety Capacitors - Avoiding the Confusion
Ceramic Safety Capacitors - Avoiding the Confusion
KEMET Electronics Corporation
 

What's hot (18)

Htr india-products-current-sense-resistors-electron-beam-welded-heb-english
Htr india-products-current-sense-resistors-electron-beam-welded-heb-englishHtr india-products-current-sense-resistors-electron-beam-welded-heb-english
Htr india-products-current-sense-resistors-electron-beam-welded-heb-english
 
Htr india-products-current-sense-resistors-electron-beam-welded-heb-english
Htr india-products-current-sense-resistors-electron-beam-welded-heb-englishHtr india-products-current-sense-resistors-electron-beam-welded-heb-english
Htr india-products-current-sense-resistors-electron-beam-welded-heb-english
 
ABB Medium Voltage MV Surge Arresters - AC & DC Surge Arresters & Protection...
ABB Medium Voltage MV Surge Arresters -  AC & DC Surge Arresters & Protection...ABB Medium Voltage MV Surge Arresters -  AC & DC Surge Arresters & Protection...
ABB Medium Voltage MV Surge Arresters - AC & DC Surge Arresters & Protection...
 
Advances in Ceramic Capacitors
Advances in Ceramic CapacitorsAdvances in Ceramic Capacitors
Advances in Ceramic Capacitors
 
1 reliability qualification report pcb
1 reliability qualification report pcb1 reliability qualification report pcb
1 reliability qualification report pcb
 
T540 and t541 new features
T540 and t541 new featuresT540 and t541 new features
T540 and t541 new features
 
Htr india-products-wire-wound-resistors-silicone-coated-resistors-hia-english...
Htr india-products-wire-wound-resistors-silicone-coated-resistors-hia-english...Htr india-products-wire-wound-resistors-silicone-coated-resistors-hia-english...
Htr india-products-wire-wound-resistors-silicone-coated-resistors-hia-english...
 
SEBA KMT Cable Fault Locators, Surge Generators (Thumpers) - SEBA KMT Cable F...
SEBA KMT Cable Fault Locators, Surge Generators (Thumpers) - SEBA KMT Cable F...SEBA KMT Cable Fault Locators, Surge Generators (Thumpers) - SEBA KMT Cable F...
SEBA KMT Cable Fault Locators, Surge Generators (Thumpers) - SEBA KMT Cable F...
 
Technical specification for 3.ph 4 wire stw 12 02-11
Technical specification for 3.ph 4 wire stw 12 02-11Technical specification for 3.ph 4 wire stw 12 02-11
Technical specification for 3.ph 4 wire stw 12 02-11
 
Htr india-products-current-sense-resistors-electron-beam-welded-heb-english
Htr india-products-current-sense-resistors-electron-beam-welded-heb-englishHtr india-products-current-sense-resistors-electron-beam-welded-heb-english
Htr india-products-current-sense-resistors-electron-beam-welded-heb-english
 
Sar07030 series 2016
Sar07030 series 2016Sar07030 series 2016
Sar07030 series 2016
 
Newson Gale Bond Rite Clamp
Newson Gale Bond Rite ClampNewson Gale Bond Rite Clamp
Newson Gale Bond Rite Clamp
 
Abb low voltage lv capacitors, abb clmd
Abb low voltage lv capacitors, abb clmd  Abb low voltage lv capacitors, abb clmd
Abb low voltage lv capacitors, abb clmd
 
Uniohm resistors datasheet for car -anti-sulfurized thick film chip resistors...
Uniohm resistors datasheet for car -anti-sulfurized thick film chip resistors...Uniohm resistors datasheet for car -anti-sulfurized thick film chip resistors...
Uniohm resistors datasheet for car -anti-sulfurized thick film chip resistors...
 
ABB POLIM-C..LB Medium Voltage Surge Arresters AC up to 5kV - AC Surge Arrest...
ABB POLIM-C..LB Medium Voltage Surge Arresters AC up to 5kV - AC Surge Arrest...ABB POLIM-C..LB Medium Voltage Surge Arresters AC up to 5kV - AC Surge Arrest...
ABB POLIM-C..LB Medium Voltage Surge Arresters AC up to 5kV - AC Surge Arrest...
 
Data Teknis Gossen Metrawatt Insulation Tester METRISO INTRO-METRISO BASE-MET...
Data Teknis Gossen Metrawatt Insulation Tester METRISO INTRO-METRISO BASE-MET...Data Teknis Gossen Metrawatt Insulation Tester METRISO INTRO-METRISO BASE-MET...
Data Teknis Gossen Metrawatt Insulation Tester METRISO INTRO-METRISO BASE-MET...
 
ABB POLIM-C..N High Voltage Surge Arresters AC up to 7.5 kV - AC Surge Arrest...
ABB POLIM-C..N High Voltage Surge Arresters AC up to 7.5 kV - AC Surge Arrest...ABB POLIM-C..N High Voltage Surge Arresters AC up to 7.5 kV - AC Surge Arrest...
ABB POLIM-C..N High Voltage Surge Arresters AC up to 7.5 kV - AC Surge Arrest...
 
Ceramic Safety Capacitors - Avoiding the Confusion
Ceramic Safety Capacitors - Avoiding the ConfusionCeramic Safety Capacitors - Avoiding the Confusion
Ceramic Safety Capacitors - Avoiding the Confusion
 

Similar to 1.MCB -Meba

Catalogue MCCB Fuji - Beeteco.com
Catalogue MCCB Fuji - Beeteco.comCatalogue MCCB Fuji - Beeteco.com
Catalogue MCCB Fuji - Beeteco.com
Beeteco
 
06 - MCCB & ACB - Fuji Electric
06 - MCCB & ACB - Fuji Electric06 - MCCB & ACB - Fuji Electric
06 - MCCB & ACB - Fuji Electric
CTY TNHH HẠO PHƯƠNG
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900
Dien Ha The
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.orgFuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
Dien Ha The
 
Fuji thiet bi dien-catalogue-mccb-fuji
Fuji thiet bi dien-catalogue-mccb-fujiFuji thiet bi dien-catalogue-mccb-fuji
Fuji thiet bi dien-catalogue-mccb-fuji
Thuan Kieu
 
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.orgFuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
Dien Ha The
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900
Thuan Kieu
 
Catalog cs fdp dienhathe.vn
Catalog cs fdp dienhathe.vnCatalog cs fdp dienhathe.vn
Catalog cs fdp dienhathe.vn
Dien Ha The
 
Catalog cs fdp
Catalog cs fdpCatalog cs fdp
Catalog cs fdp
Dien Ha The
 
Catalog cs mcb rccb
Catalog cs mcb rccbCatalog cs mcb rccb
Catalog cs mcb rccb
Dien Ha The
 
Catalog cs mcb rccb dienhathe.vn
Catalog cs mcb rccb dienhathe.vnCatalog cs mcb rccb dienhathe.vn
Catalog cs mcb rccb dienhathe.vn
Dien Ha The
 
Catalog cs mcb rccb
Catalog cs mcb rccbCatalog cs mcb rccb
Catalog cs mcb rccb
Thuan Kieu
 
Catalog cs fdp
Catalog cs fdpCatalog cs fdp
Catalog cs fdp
Thuan Kieu
 
07 - ELCB - Fuji Electric
07 - ELCB - Fuji Electric07 - ELCB - Fuji Electric
07 - ELCB - Fuji Electric
CTY TNHH HẠO PHƯƠNG
 
Catalog MCCB & ACB Fuji Electric dòng G-TWIN Mới Nhất 2019
Catalog MCCB & ACB Fuji Electric dòng G-TWIN Mới Nhất 2019Catalog MCCB & ACB Fuji Electric dòng G-TWIN Mới Nhất 2019
Catalog MCCB & ACB Fuji Electric dòng G-TWIN Mới Nhất 2019
CTY TNHH HẠO PHƯƠNG
 
Thông số MCB LS
Thông số MCB LSThông số MCB LS
Dienhathe.com miniature circuit breakers
Dienhathe.com miniature circuit breakersDienhathe.com miniature circuit breakers
Dienhathe.com miniature circuit breakers
Dien Ha The
 
Fuji thiet bi dien-elcbfuji-160413044256
Fuji thiet bi dien-elcbfuji-160413044256Fuji thiet bi dien-elcbfuji-160413044256
Fuji thiet bi dien-elcbfuji-160413044256
Thuan Kieu
 
Fuji thiet bi dien-elcbfuji-160413044256 dienhathe.org
Fuji thiet bi dien-elcbfuji-160413044256 dienhathe.orgFuji thiet bi dien-elcbfuji-160413044256 dienhathe.org
Fuji thiet bi dien-elcbfuji-160413044256 dienhathe.org
Dien Ha The
 
Thông số kĩ thuật siemens miniature circuit breakers
Thông số kĩ thuật siemens miniature circuit breakersThông số kĩ thuật siemens miniature circuit breakers

Similar to 1.MCB -Meba (20)

Catalogue MCCB Fuji - Beeteco.com
Catalogue MCCB Fuji - Beeteco.comCatalogue MCCB Fuji - Beeteco.com
Catalogue MCCB Fuji - Beeteco.com
 
06 - MCCB & ACB - Fuji Electric
06 - MCCB & ACB - Fuji Electric06 - MCCB & ACB - Fuji Electric
06 - MCCB & ACB - Fuji Electric
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.orgFuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
 
Fuji thiet bi dien-catalogue-mccb-fuji
Fuji thiet bi dien-catalogue-mccb-fujiFuji thiet bi dien-catalogue-mccb-fuji
Fuji thiet bi dien-catalogue-mccb-fuji
 
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.orgFuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900
 
Catalog cs fdp dienhathe.vn
Catalog cs fdp dienhathe.vnCatalog cs fdp dienhathe.vn
Catalog cs fdp dienhathe.vn
 
Catalog cs fdp
Catalog cs fdpCatalog cs fdp
Catalog cs fdp
 
Catalog cs mcb rccb
Catalog cs mcb rccbCatalog cs mcb rccb
Catalog cs mcb rccb
 
Catalog cs mcb rccb dienhathe.vn
Catalog cs mcb rccb dienhathe.vnCatalog cs mcb rccb dienhathe.vn
Catalog cs mcb rccb dienhathe.vn
 
Catalog cs mcb rccb
Catalog cs mcb rccbCatalog cs mcb rccb
Catalog cs mcb rccb
 
Catalog cs fdp
Catalog cs fdpCatalog cs fdp
Catalog cs fdp
 
07 - ELCB - Fuji Electric
07 - ELCB - Fuji Electric07 - ELCB - Fuji Electric
07 - ELCB - Fuji Electric
 
Catalog MCCB & ACB Fuji Electric dòng G-TWIN Mới Nhất 2019
Catalog MCCB & ACB Fuji Electric dòng G-TWIN Mới Nhất 2019Catalog MCCB & ACB Fuji Electric dòng G-TWIN Mới Nhất 2019
Catalog MCCB & ACB Fuji Electric dòng G-TWIN Mới Nhất 2019
 
Thông số MCB LS
Thông số MCB LSThông số MCB LS
Thông số MCB LS
 
Dienhathe.com miniature circuit breakers
Dienhathe.com miniature circuit breakersDienhathe.com miniature circuit breakers
Dienhathe.com miniature circuit breakers
 
Fuji thiet bi dien-elcbfuji-160413044256
Fuji thiet bi dien-elcbfuji-160413044256Fuji thiet bi dien-elcbfuji-160413044256
Fuji thiet bi dien-elcbfuji-160413044256
 
Fuji thiet bi dien-elcbfuji-160413044256 dienhathe.org
Fuji thiet bi dien-elcbfuji-160413044256 dienhathe.orgFuji thiet bi dien-elcbfuji-160413044256 dienhathe.org
Fuji thiet bi dien-elcbfuji-160413044256 dienhathe.org
 
Thông số kĩ thuật siemens miniature circuit breakers
Thông số kĩ thuật siemens miniature circuit breakersThông số kĩ thuật siemens miniature circuit breakers
Thông số kĩ thuật siemens miniature circuit breakers
 

More from Meba Electric Co.,Ltd

Meba push button switches
Meba push button switchesMeba push button switches
Meba push button switches
Meba Electric Co.,Ltd
 
Moulded case circuit breaker
Moulded case circuit breakerMoulded case circuit breaker
Moulded case circuit breaker
Meba Electric Co.,Ltd
 
Earth leakage circuit breaker
Earth leakage circuit breakerEarth leakage circuit breaker
Earth leakage circuit breaker
Meba Electric Co.,Ltd
 
Distribution box
Distribution boxDistribution box
Distribution box
Meba Electric Co.,Ltd
 
Light bar&elec bell
Light bar&elec bellLight bar&elec bell
Light bar&elec bell
Meba Electric Co.,Ltd
 
Moulded case circuit breaker
Moulded case circuit breakerMoulded case circuit breaker
Moulded case circuit breaker
Meba Electric Co.,Ltd
 
AC Contactor
AC ContactorAC Contactor
AC Contactor
Meba Electric Co.,Ltd
 
Earth leakage circuit breaker
Earth leakage circuit breakerEarth leakage circuit breaker
Earth leakage circuit breaker
Meba Electric Co.,Ltd
 
Distribution box
Distribution boxDistribution box
Distribution box
Meba Electric Co.,Ltd
 
Industrial socket&plug
Industrial socket&plugIndustrial socket&plug
Industrial socket&plug
Meba Electric Co.,Ltd
 
Changeover switch
Changeover switchChangeover switch
Changeover switch
Meba Electric Co.,Ltd
 
Temperature controller
Temperature controllerTemperature controller
Temperature controller
Meba Electric Co.,Ltd
 
High voltage products
High voltage productsHigh voltage products
High voltage products
Meba Electric Co.,Ltd
 
Meters made by Meba Electric Co.,Ltd
Meters made by Meba Electric Co.,LtdMeters made by Meba Electric Co.,Ltd
Meters made by Meba Electric Co.,Ltd
Meba Electric Co.,Ltd
 
Mini circuit breaker
Mini circuit breakerMini circuit breaker
Mini circuit breaker
Meba Electric Co.,Ltd
 
Residual current-circuit-breaker www.meba.net
Residual current-circuit-breaker www.meba.netResidual current-circuit-breaker www.meba.net
Residual current-circuit-breaker www.meba.net
Meba Electric Co.,Ltd
 
Low voltage-distribution-cabinet
Low voltage-distribution-cabinetLow voltage-distribution-cabinet
Low voltage-distribution-cabinet
Meba Electric Co.,Ltd
 
Push button switches
Push button switchesPush button switches
Push button switches
Meba Electric Co.,Ltd
 
Meba proximity switch
Meba proximity switchMeba proximity switch
Meba proximity switch
Meba Electric Co.,Ltd
 
Meba fuse
Meba fuseMeba fuse

More from Meba Electric Co.,Ltd (20)

Meba push button switches
Meba push button switchesMeba push button switches
Meba push button switches
 
Moulded case circuit breaker
Moulded case circuit breakerMoulded case circuit breaker
Moulded case circuit breaker
 
Earth leakage circuit breaker
Earth leakage circuit breakerEarth leakage circuit breaker
Earth leakage circuit breaker
 
Distribution box
Distribution boxDistribution box
Distribution box
 
Light bar&elec bell
Light bar&elec bellLight bar&elec bell
Light bar&elec bell
 
Moulded case circuit breaker
Moulded case circuit breakerMoulded case circuit breaker
Moulded case circuit breaker
 
AC Contactor
AC ContactorAC Contactor
AC Contactor
 
Earth leakage circuit breaker
Earth leakage circuit breakerEarth leakage circuit breaker
Earth leakage circuit breaker
 
Distribution box
Distribution boxDistribution box
Distribution box
 
Industrial socket&plug
Industrial socket&plugIndustrial socket&plug
Industrial socket&plug
 
Changeover switch
Changeover switchChangeover switch
Changeover switch
 
Temperature controller
Temperature controllerTemperature controller
Temperature controller
 
High voltage products
High voltage productsHigh voltage products
High voltage products
 
Meters made by Meba Electric Co.,Ltd
Meters made by Meba Electric Co.,LtdMeters made by Meba Electric Co.,Ltd
Meters made by Meba Electric Co.,Ltd
 
Mini circuit breaker
Mini circuit breakerMini circuit breaker
Mini circuit breaker
 
Residual current-circuit-breaker www.meba.net
Residual current-circuit-breaker www.meba.netResidual current-circuit-breaker www.meba.net
Residual current-circuit-breaker www.meba.net
 
Low voltage-distribution-cabinet
Low voltage-distribution-cabinetLow voltage-distribution-cabinet
Low voltage-distribution-cabinet
 
Push button switches
Push button switchesPush button switches
Push button switches
 
Meba proximity switch
Meba proximity switchMeba proximity switch
Meba proximity switch
 
Meba fuse
Meba fuseMeba fuse
Meba fuse
 

1.MCB -Meba

  • 1. 08 Technical parameter: Pole Rated Voltage(Un) Rated Current IN Rated frequency fN Rated breaking capacity Energy limiting class Tripping characteristic 1, 2, 3, 4 230(240)/400(415)V AC, max.60V DC 0.5-63A 50HZ 6KA 3 B,C,D B EN 50022 18mm/pole IEC 60898, EN60898 2 1-25mm Isolating class Mounting on the rail Build-in width Standards Cross-section of connecting lead 77=0.8 45 35.6=0.3 44 65.7 5.5 80=0.8 18 Dimensions(mm): Operation Principle Fig: 1Pole 1 2 2Pole 1 2 3 4 N N 3Pole 1 2 3 4 5 6 4Pole 1 2 3 4 5 6 8 7 N N Technical parameter: Pole Rated Voltage(Un) Rated Current IN Rated frequency fN Rated breaking capacity Energy limiting class Tripping characteristic 1, 2, 3, 4 230(240)/400(415)V AC, max.60V DC 0.5-63A 50HZ 6KA 3 B,C,D B EN 50022 18mm/pole IEC 60898, EN60898 2 1-25mm Isolating class Mounting on the rail Build-in width Standards Cross-section of connecting lead 77=0.8 45 35.6=0.3 44 65.7 5.5 80=0.8 18 Dimensions(mm): Operation Principle Fig: 1Pole 1 2 2Pole 1 2 3 4 N N 3Pole 1 2 3 4 5 6 4Pole 1 2 3 4 5 6 8 7 N N OLB7-1P/2P Miniature Circuit Breaker OLB7-3P Miniature Circuit Breaker www.meba.net Miniature Circuit Breaker OLB7-3POLB7-1P/2P
  • 2. BH Miniature Circuit Breaker Features and Applications: BH seriesminiature circuit breakeris characteristicof smallsize, light weight,novel structure and excellent performance. They are mounted in the illuminating distribution board and used in guest house s, block of flats, high buildings, squar es, airports, railway stations, plants and enterprises etc. inACcircuits 240V (single pole) up to 415V(3 pole) 50Hz for protection of overload short circuit and forcircuit change-over in lighting sys tem. Breaking capacity is 3KA. The items comply with IEC60898 standard. Technical parameter: Number of Poles Rated Current (A) Rated Voltage(V) Breaking Capacity(A) Electrical Life(Times) Mechanical Life(Times) 1P,2P,3P 6, 10, 15, 20, 25, 30, 40, 50, 63, 70,80, 90, 100 110/220 (1P), 240/415 (2P), 415(3P) 3000 6000 16000 Dimension(mm): 75 50 25 95 3P 2P 1P 77 64 100 BH-P Miniature Circuit Breaker Applications: BH-P series miniature circuit breaker applies to industrial, commerical, lighting and electric machine distrib ution system with AC415V, 50/60Hz, ratedworking currentup to100Ato protect against overload and short circuit.The itemis installed intoplug-in type mounting base. Technical parameter: Number of Poles Rated Current (A) Rated Voltage(V) Breaking Capacity(A) Electrical Life(Times) Mechanical Life(Times) 1P,2P,3P 6, 10, 15, 20, 25, 30, 40, 50, 63, 70,80, 90, 100 110/220 (1P), 240/415 (2P), 415(3P) 3000 6000 16000 Dimension(mm): 25 20.7 30 ON SOFAB 57.4 75 89 77 64.2 61 75 57.4 www.meba.net Miniature Circuit Breaker BH 09 BH-P
  • 3. www.mebamfg.com Miniature Circuit Breaker MBGLD4/MBGLD4A Miniature Circuit Breaker Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBGLD4/ MBGLD4A IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35 mm MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current ( Type C ), 3 to 5 times rated current ( Type B ), 10 to 14 times rated current ( TypeD ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE CB ISO9001-2000awarded bythecompetentcertification body, Mebais qualifiedinthemanufacturing ofthe object IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging is sure that withstand anyadverse conditions duringtransport and handling to the warehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days A Vac Hz kA 2 mm A 93% RH at 25 50% RH at 40 -5 a 40 6/10/16/20/25/32/40/50/63 240/415 50/60 6 -5 a 40 IP20 1/2/3/4 25 4000 8000 B/C/D Type B: 3 a 5 In Type C: 5 a10 In Type D: 10 a 14 In attach 10 MBGLD4AMBGLD4
  • 4. MBBH Miniature Circuit Breaker Applications: MBBH series miniature circuit breaker, major export to South America, Middle East market, has light weight, smallsize, novel structure and excellent performance. They are mounted in the metal distribution boar d and used in guesthouses. block of fiats, high buildings, squares, airpo rts, railway stations, plants and enterprises etc, in AC circuits 240V(single pole) up to 415V(3poie) 50Hz for protectionof overload short circuitand for circuitchangeover in lightingsystem. Breaking capacityis 3KA.The items complywith BS&NEMASTANDARD. Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century, Year, Month and Batch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization A Vac Hz kA 2 mm A Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBBH IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention NEMA Type MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 10 to 14 times rated current ( Type D) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectively dissipates the electric arcthat is generatedby the openingcontacts of thetrigger mechanism in the presence of an overload or short circuit. CE ISO 9001-2000 awardedby the competent certification body, Meba is qualifiedin the manufacturingof the object IEC 60947 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving thecircuit breakers (breakers),customers may performthe tests maybe necessary toensure compliance with the technical specifications. The packaging is sure that withstand any adverse conditions during transport and handling to the warehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days 93% RH at 25 10 a 60 6/10/15/20/30/40/50/60 120/240/415 50/60 3 -5 a +40 IP20 1, 2, 3, 4 25 4000 6000 B/C/D Type B 3 a 5 In Type C 5 a 10 In Type D 10 a 14 In attach www.meba.net Miniature Circuit Breaker 11 MBBH
  • 5. MABD Miniature Circuit Breaker Specification needs: Manufacturer: Meba Electric Enterprises Country of Origin: china Brand: meba Model: MABD IEC 60898 IEC60947-2 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230 V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention NEMA TYPE MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C). BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. Semko CB ISO9001-2000, awardedby the competentcertification body, Mebais qualifiedin the manufacturingof the object IEC 60898 standards awarded by an international certifying body. Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receivingthe circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging is sure that withstand any adverse conditions during transport and handling to the warehouse of cutomers. In one of its sides the breaker is marked with the symbol permanent ink, year, month and batch. Attach catalogs indicating the technical specifications Submit sample of the product offered 2 YEARS CNF & FOB 25 DAYS A Vac Hz kA 93% RH at 25 10 a 60 6110/6/20/25/32/40/50/63 120/240/415 50/60 6 40 IP20 1/2/3/4 25 4000 8000 B/C/D 5 a 10 In attach Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month and Batch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization 2 mm A www.meba.net Miniature Circuit Breaker 12 MABD
  • 6. Applications: GV series motor protection circuit breaker are mainly used for the overload and short circuit protection of motors in AC50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motors, under the AC3 load or for the overload and short circuit protection of the circuitand power equipment in the power in the power distribution network. Technical parameter: Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Type Setting range 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1 1-1.6 1.6-2.5 2.5-4 4-6 6-10 10-16 16-20 20-25 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1 1-1.6 1.6-2.5 2.5-4 4-6.3 6-10 9-14 13-18 17-23 20-25 24-32 660V KW -- -- -- 0.37 0.55 1.1 1.5 3 4 7.5 11 15 18.5 -- -- -- 0.37 0.55 1.1 1.5 3 4 7.5 9 11 15 18.5 26 500V KW -- -- -- -- 0.37 0.75 1.1 2.2 3.7 5.5 10 11 15 -- -- -- -- 0.37 0.75 1.1 2.2 3.7 5.5 7.5 9 11 15 18.5 440V KW -- -- -- -- 0.37 0.55 1.1 1.5 3 4 7.5 9 11 -- -- -- -- 0.37 0.55 1.1 1.5 3 4 7.5 9 11 11 15 415V KW -- -- -- -- -- -- 1.1 1.5 2.2 4 7.5 9 11 -- -- -- -- -- -- 0.75 1.5 2.2 4 5.5 9 11 11 15 380V KW -- -- -- -- -- 0.37 0.75 1.5 2.2 4 7.5 10 11 -- -- -- -- -- 0.37 0.75 1.5 2.2 4 5.5 7.5 11 11 15 220V KW -- -- -- -- -- -- 0.37 0.75 1.1 2.2 4 5.5 5.5 -- -- -- -- -- -- 0.37 0.75 1.1 2.2 3 4 5.5 5.5 7.5 GV1-M01 GV1-M02 GV1-M03 GV1-M04 GV1-M05 GV1-M06 GV1-M07 GV1-M08 GV1-M10 GV1-M14 GV1-M20 GV1-M21 GV1-M22 GV2-M01/RS01 GV2-M02/RS02 GV2-M03/RS03 GV2-M04/RS04 GV2-M05/RS05 GV2-M06/RS06 GV2-M07/RS07 GV2-M08/RS08 GV2-M10/RS10 GV2-M14/RS14 GV2-M16/RS16 GV2-M20/RS20 GV2-M21/RS21 GV2-M22/RS22 GV2-M32/RS32 www.meba.net Miniature Circuit Breaker GV2-M10/GV2ME Miniature Circuit Breaker 13 GV2-M10 GV2ME
  • 7. 18 79 36 45 45 Features and Applications: Dimension(mm): C45D Indicator Din Rail type LED Indicator, Neon Signal Lamp The DIN Rail type Modular Signal Lamp is applicable to circuit with rated voltage 230V AC, 50/60Hz for visual indication and signaling. Low service duration, minimum power consumption Compact design in modular size, easy installation Rated voltage: 230V AC, 50/60Hz Colour: Red, green, yellow Connection terminal: Pillar terminal with clamp 2 Connection capacity: Rigid conductor 10mm Installation: - On symmetrical DIN rail - Panel mounting Illumination type: A. Illumination: LED - Max power: 0.6W - Service duration: 30, 000 hours B. Illumination: Neon bulb - Max power: 1.2W - Service duration: 15, 000 hours CPKZM0-1.0 Miniature Circuit Breaker CPKZ M0 Motor Protective Circuit Breaker isapplicable for the circuit of AC50/60Hz, rated insulation voltage 750V, rated operating voltage up to 660V, rated operating current from 0.1A to 25A. Itis used forprotecting the motoragainst overlo ad, short-circuit and phase-failure. It can bealso used forstarting and breaking the starter of motor and for the circuit protection in the circuit of 25A. Motor Protective Circuit Breakers (CPKZM) Features and Applications: Screw or DIN rail mounting Thermal and electromagnetic trip Rated operational current up to 25A Switching capacity 150/50KA/415V Short-circuit release, fixed setting to 14X Iu Single-phasing sensitive With screws or spring loaded terminals Comply with IEC/EN6094 Technical parameter: Standard power ratings of 3-phase motors 50/60Hz in category AC-3(kW) Setting range of overload tripping current Ir(A) Norminal breaking capacity(A) Rated operating current 400V Ie(A) Reference - 0.06 0.09 0.12 0.25 0.55 0.75 1.5 2.2 3 4 5.5 7.5 9 12.5 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1 1-1.6 1.6-2.5 2.5-4 4-6.3 6.3-10 6.3-10 10-16 10-16 16-20 20-25 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 6.6 10 16 16 20 25 CPKZM0-01 CPKZM0-02 CPKZM0-03 CPKZM0-04 CPKZM0-05 CPKZM0-06 CPKZM0-07 CPKZM0-08 CPKZM0-10 CPKZM0-14 CPKZM0-16 CPKZM0-20 CPKZM0-21 CPKZM0-22 CPKZM0-32E www.meba.net Miniature Circuit Breaker 14 C45DCPKZM0-1.0
  • 8. C45N Miniature Circuit Breaker Features and Applications: C45N series miniature circuit breaker isused in lightingdistribution system or motor distribution system for protection overload and short-circuit in the system. The product is neoteric in structure, light in weight, reliable and excellent in performance. It has high breaking capacity, can trip quickly, and its case and items are adoptedby highfire-resistant and shockproofplastics. The product, with long life, is mainly used in AC 50Hz/60Hz single-pole 230V or two, three,four pole 400Vcircuit for overloadand short-circuit protection as well as forunfrequent on-and-off switching electric equipment and lighting circuit innormal case. The products comply with IEC 60898. Technical parameter: Number of Poles Rated Current (A) Breaking Capacity (A) Rated Voltage (V) Rated Frequency Endurance Circumstance Temperature Electrical Life Mechanical Life 1P,1P+N, 2P, 3P, 3P+N, 4P 1, 2, 3, 4, 6, 10, 16, 20, 25, 32,40, (50, 63) 6000, (4500) 230/400 50/60Hz 4000 -5+40 no less than 6000 operations (O-C) no less than 20000 operations Characteristic Curve: 10000 5000 1H 2000 1000 500 200 100 50 20 10 5 2 1 0.5 0.2 0.1 0.05 0.02 0.01 0.005 0.002 0.001 0.5 1 2 3 4 5 7 10 20 30 5 0 70 100 200 I /1K t(s) B type 3-5In C type 5-10In D type 10-14In short circuit prospective short-circuit current peak value prospective short-circuit energy Current-limiting peak value Current-limiting short-circuit energy times 0 2ms 10ms Dimension(mm): 4P 3P 2P 1P 72 54 36 18 70 40 77 45 35 27 75 L www.meba.net Miniature Circuit Breaker 15 C45N
  • 9. AEG E90 E91 E92 E93 S90 S91 S92 S93 Miniature circuit breaker (MCB) NEW AEG E90 E91 E92 MCB Rated Current: 6-63A Quality guarantee: 5 years CE CB certificated Applications: The productis mainly used inAC50/60Hz single pole230V or two, three, four pole400Vvoltage for overload and short-circuitprotection as well asfor unfrequenton-and-off switching electric equipment and lighting circuitunder nrmal conditionl, the productis suitabl e for industry, business, building, ressidenc e, etc. It's conformity with GB10963, IEC60898 standards. C47-3P Miniature Circuit Breaker Characteristic Curve: 10000 5000 1H 2000 1000 500 200 100 50 20 10 5 2 1 0.5 0.2 0.1 0.05 0.02 0.01 0.005 0.002 0.001 0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/1K t(s) B type 3-5In C type 5-10In D type 10-14In Technical parameter: Rated current: 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A Tripping characteristics: B(3-5)In, C(5-10)In, D(10-15)In No. of pole: 1P, 2P, 3P, 4P Breaking capacity: 4.5KA, 6KA Standard Number of poles Rated current(In) Rated voltage(Un) Rated frequency Tripping curve Release action characteristics Magnetic releases operate Rated breaking capacit(Lcn) Endurance Circumstance temperature Electrical life Mechanical life Tropical ration Protection degree IEC60898 1P,2P,3P,4P 6, 10, 16, 20, 25, 32, 40, 50, 63 AC240/415V 50/60Hz B, C, D 1.13In>1h Non-trip 1.45In<1h trip 2.55In 1s-60S trip 5In>0.1s Non-trip 10In<0.1s trip B curve:between 3 and 5In C curve:between 5 and 10In D curve:between 10 and 15In 3000A >2500 -5 to +40 >6000times 20000 times Treatmen 2(RH95%, at 55) IP20 Time delay Instantaneous(Curve C) Miniature Circuit Breaker www.meba.net 16 C47-3P
  • 10. 35 27 75 L 10000 5000 0.5 1 2 34 5 7 10 20 30 50 70 100 200 I/1K B 3-5In type C 5-10In type D 10-14In type 2000 1000 500 200 100 50 20 10 5 2 1 0.5 0.2 0.1 0.05 0.02 0.01 0.005 0.002 0.001 Characteristic Curve: 18 0.9 36 1.25 54 1.5 72 1.5 49.5 1.25 73 1.5 81 35.51.25 45.51.25 Standard IEC898 IEC847-2 Rated current (A) 1, 2, 3, 4, 5, 6, 10, 16, 20, 25, 32, 40, 50, 63A 1, 2, 3, 4, 5, 6, 10, 16, 20, 25, 32, 40, 50, 63A Character Voltage (V) 230/240 380/415 130 230/240 400/415 230/240 400/415 Pole 1 2, 3, 4 1 Breaking Capacity (A) 6000 6000 20000 10000 3000 20000 10000 2, 3, 4 B C D Features and Applications: C65N Miniature Circuit Breaker The products of C65N belong to the advanced level of nineties in the international instead of the older generation of C45N. They have protective function as shortage and overload, and are used in lighting distributionsystem in industry, commerce and dwelling, and protecting fractional electrical motors. And they also have many merits of high protective grade (up to IP20), high breaking capacity, reliable sensitive action, convenient , multipole assembling long lifeetc. They are mainly adapted to the circuit of AC 50Hz, 230V in single pole, 400V in double, three, four poles for protecting overloadand shortcircuit. Meanwhile, theyare also used in turningon or off the electrical apparatus and lighting circuit under the normal conditions. Technical parameter: Dimension(mm): www.meba.net Miniature Circuit Breaker 17 C65N
  • 11. XYDB7-3P Miniature Circuit Breaker Features and Applications: XYDB7 have protective function as shortage as overload, and used in lighting distribution system, industry, commerce, and protect fractional electric motors. And they also have many merits of high protective grade (upto IP20), high break capacity, reliable sensitive action, convenient, multipol e assembling, long life etc. They are mainly adapted to the circuit of AC 50Hz,230V in single pole,400V in double, three, fourpoles for protectingoverload and shortcircuit. Meanwhile, theyare also usedin turning on oroff the electric apparatus and lighting circuit under the normal condition. Technical parameter: Electrical specification Conforms to standard of electrical EN60898 (IEC898 GB10963-99) 230V/400V; 50/60Hz 10KA IEC898 (0.5 63A) 15KA IEC947-2 (0.5 63A) Max.48V (KL7..., 10KA) single pole Max.250v (Kl7-DC, 6KA) single pole C,D charaectisistic curve 100AgL ( 10KA) 3 -5 to + 40 P40 (Under mounting) No less than 8000 times No less than 20000 times 45mm 80mm 17.5mm per pole (single pole) 35mm: 1P+N (two pole) Used for track of 35mm of IEC standard Two-function terminal can connect with busbar and conducting wire 2 Wire 1-25mm Conducting wire 0.8-2mm Terminal block capacity Enclosure width The length of exposed plane Enclosure height Life: Electrical Mechnical Perfermance Max.fuse that can be connected to Selective grade Working ambient temperature Enclosed protective class Short circuit breaking capacity of DC Rated current (Ue) Mounting manner Terminal manner Miniature Circuit Breaker www.meba.net 18 XYDB7-3P
  • 12. Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization Operation Indicator Window A Vac Hz kA 2 mm A Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MB1-63 IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230 V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve C Characteristic Intervention FOR RIEL DIN 35 mm The circuit breaker have an operating window colordisplay that shows the state inwhich it is ( connected or disconnected ). MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current ( TypeC ), 3 to 5 times rated current ( Type B), 10 to 14 times rated current ( Type D ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE CB ISO9001-2000awarded bythe competentcert ifica tion body, Mebais qualifi ed in the manufacturing of the object IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging is sure that withstand any adverse conditions during transport and handling to the warehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days 93% RH at 25 10 a 60 6/10/16/20/25/32/40/50/63 240/415 50/60 6 40 IP20 1/2/3/4 25 4000 10000 B/C/D 5 a 10 In attach MB1-63 Miniature Circuit Breaker www.meba.net Miniature Circuit Breaker 19 MB1-63
  • 13. Charcteristic Curve: 10000 5000 B type 2000 1000 500 200 100 50 0.2 0.1 20 10 5 2 1 0.5 0.05 0.02 0.01 0.005 0.002 0.001 Time(s) 0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In 10000 5000 C type 2000 1000 500 200 100 50 0.2 0.1 20 10 5 2 1 0.5 0.05 0.02 0.01 0.005 0.002 0.001 Time(s) 0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In 10000 5000 D type 2000 1000 500 200 100 50 0.2 0.1 20 10 5 2 1 0.5 0.05 0.02 0.01 0.005 0.002 0.001 Time(s) 0.5 1 2 3 4 5 7 1014 20 30 50 70 100 200 I/In MB1-63 Miniature Circuit Breaker Dimension(mm): 4P 3P 2P 1P 72 54 36 18 82 35 45 76 Miniature Circuit Breaker www.meba.net 20 MB1-63
  • 14. Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization Operation Indicator Window A Vac Hz kA 2 mm A 93% RH at 25 10 a 60 6/10/16/20/25/32/40/50/63 240/415 50/60 10 40 IP20 1 1+N 2 3 3+N 4 25 4000 8000 B/C/D Type B 3 a 5 In Type C 5 a 10 In Type D 10 a 14 In attach Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MB7 IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230 V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35 mm The circuit breaker have an operating window color display that shows the state in which it is ( connected or disconnected ). MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following range s: 5 to 10 times rated current ( TypeC ), 3 to 5 times rated current ( Type B), 10 to 14 times rated current ( Type D ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE CB ISO9001-2000 awarded by thecompetent certification body, Mebais qualified in themanufacturing of theobject IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging is surethat withstandany adverse conditions duringtransportand handling to thewarehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days MB7 Miniature Circuit Breaker www.meba.net Miniature Circuit Breaker 21 MB7
  • 15. MB7 Miniature Circuit Breaker Dimension(mm): 35 52.5 70 2P 3P 3P+N 80 80 80 70 4P 80 17.5 80 1P 1P+N 26.3 8045 11 44 30.5 4.55.5 60 Dimension(mm): MB040 Time Relay 18 63.5 44.5 45.5 35 95 6 Miniature Circuit Breaker www.meba.net 22 MB040MB7
  • 16. MB040 Time Relay Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization A Vac Hz kA 2 mm A Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MB040 IEC 60898 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35 mm MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current ( TypeC ). BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. ISO 9001-2000 IEC 60898 standards Curve compliance issued Shot by an accredited laboratory for effect Life, given by us to ensure that the life of the goods offered by atleast 5 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. We are surethe packaging withstandany adverse conditionsduring transp ort and handling to the cellar s of the Company. Carton or Pallet In one of its sides the breaker is marked with the symbol permanent ink, year, month and batch. Available Submit sample of the product offered 2 YEARS CIF CNF FOB 25 Days 93% RH at 25 10 a 60 6/16/20/25/32 120/240/415 50/60 3/4.5/6 40 IP20 1 25 4000 8000 C 5 a 10 In attach www.meba.net Miniature Circuit Breaker 23 MB040
  • 17. MB043 Isolator Specification needs: Electrical Properties Type of Assembly Present Certificates Testing For Acceptance Packing Dial Century, Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization A Vac Hz kA 2 mm A Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MB043 Isolator IEC 60947-3 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35 mm ISO 9001-2000 IEC 60947-3 standards Life, given by us to ensure that the life of the goods offered by atleast 5 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. We are surethe packaging withstandany adverse conditions during transport and handling to the cellars of the Company. Carton or Pallet In one of its sides the breaker is marked with the symbol permanent ink, year, month and batch. Available Submit sample of the product offered 2 YEARS CIF CNF FOB 25 Days 93% RH at 25 10 a 60 6/16/20/25/32 120/240/415 50/60 0 40 IP20 1/2/3/4 25 4000 8000 / / attach Miniature Circuit Breaker www.meba.net 24 MB043
  • 18. MB32 DPN Applications: MB32 series is mainly for protecton of circuits with AC220V and 50Hz/60Hz, and for unfrequent conversion under normal conditions as well. Its action can be up to two pole with its only one pole volume and be used as a leakage breaker by assembling with leakage. It is produced perEN60.898,IEC947-2 standards. Over-current tripping characteristic: Tripping Tripping rated current(InA) Beginning state Test current Norminative Time Test result Note C Cold state Heat state Cold state Cold state Cole state 1.13In 1.45In 2.55In 5In 10In t 1h t 1h 1s t 60s t 0.1h t 0.1s No tripping Tripping Tripping No tripping Tripping Close auxillzry switch making the circuit 40 The current will rise to norminative value in 5s Main Technical Data: Rated current A 6 10 16 20 25 32 40 Pole NO 1P+N Rated voltage(V) 240/415 Breaking capacity(KA) 4.5 Instantaneous Tripping type C Instantaneous Protection current range 5In I 10In Electric life 5000 Dimension(mm): 44.5 77 18 80 36 45 www.meba.net Miniature Circuit Breaker 25 MB32
  • 19. Specification needs: MB32 DPN Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization A Vac Hz kA 2 mm A Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MB32 IEC 60898 IEC947-2 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230 V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35 mm MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current ( TypeC ). BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE ISO9001-2000 awardedby thecompetentcertification body,Mebais qualifiedin themanufacturing of the object IEC 60898 standards in the manufacture of the goods awarded by an international certifying body. Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customer may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging is sure that withstand any adverse conditionsduring transport andhandling to thewarehouse of customer In one of its sides the breaker should be marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specifications Submit sample of the product offered 2 YEARS FOB CIF 25 Days 93% RH at 25 10 a 60 6/10/16/20/25/32/40 240/415 50/60 4.5 40 IP20 1P+N 25 5000 10000 C 5 a 10 In attach Miniature Circuit Breaker www.meba.net 26 MB32
  • 20. www.meba.net Specification needs: Miniature Circuit Breaker MBL10 Miniature Circuit Breaker Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization Operation Indicator Window 93% RH at 25 10 a 60 6/10/16/20/25/32/40/50/63 240/415 50/60 6 40 IP20 1/2/3/4 25 4000 10000 B/C/D 5 a 10 In attach A Vac Hz kA 2 mm A Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBL10 IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve C Characteristic Intervention FOR RIEL DIN 35mm The circuit breaker have an operating window color display that shows the state in which it is (connected or disconnected). MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( TypeB ), 10 to 14 times rated current ( Type D ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE CB ISO 9001-2000awarded by thecompetent certification body, Meba isqualified in themanufactu ring of the object IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging issure thatwithstandany adverse conditions during transportand handling to the warehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days 27 MBL10
  • 21. MBL11 Miniature Circuit Breaker Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization Operation Indicator Window A Vac Hz kA 2 mm A Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBL11 IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve C Characteristic Intervention FOR RIEL DIN 35mm The circuit breaker have an operating window color display that shows the state in which it is (connected or disconnected). MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( TypeB ), 10 to 14 times rated current ( TypeD ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE CB ISO9001-2000 awardedby the competentcertifica tion body, Mebais qualified inthe manufacturing of the object IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging issure that withstandany adverse condition s during transport and handling to the warehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days 93% RH at 25 -5 a 40 6/10/16/20/25/32/40/50/63 240/415 50/60 6 -5 a 40 IP20 1/2/3/4 25 6000 20000 B/C/D 5 a 10 In attach www.meba.net Miniature Circuit Breaker 28 MBL11
  • 22. Applications: Protection and control of circuit against overlo ad and short circ uit, in building installation-suchas houses, office s, commercial complex, motorsystem (D curve) and industrial installation-for switching, control, protection and regulation of electrical circuits. Also in switchgear panels, railway and marine application. Overall and mounting dimensioned chart: 18 36 54 72 70 50 73 36 81 45 MB47-1P/2P Miniature Circuit Breaker 18 36 54 72 80 36 50 66 76 45 www.meba.net Miniature Circuit Breaker MBL11 Miniature Circuit Breaker Overall & Installation Dimensions: 29 MBL11 MB47-1P
  • 23. Miniature Circuit Breaker www.meba.net MB47-1P/2P Miniature Circuit Breaker Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization A Vac Hz kA 2 mm A Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MB47-1P/ 2P IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35 mm MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current ( TypeC ), 3 to 5 times rated current ( Type B), 10 to 14 times rated current ( Type D ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE CB ISO9001-2000awarded by thecompetent certification body, Meba is qualifiedinthemanufacturing of theobject IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging is sure that withstand any adverse conditions during transport and handling to the warehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days 93% RH at 25 50% RH at 40 -5 a 40 6/10/16/20/25/32/40/50/63 240/415 50/60 6 40 IP20 1/2/3/4 25 4000 8000 B/C/D Type B: 3 a 5 In Type C: 5 a 10 In Type D: 10 a 14 In attach 30 MB47-2PMB47-1P
  • 24. www.meba.net Miniature Circuit Breaker MB48/MB49 Miniature Circuit Breaker Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MB48/ MB49 IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35 mm MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current ( TypeC ), 3 to 5 times rated current ( Type B), 10 to 20 times rated current ( Type D ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE CB ISO 9001-2000awarded by the competent certification body, Mebais qualified in themanufactu ring of theobject IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging is sure that withstand any adverse conditio ns during transport and handling tothe warehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days A Vac Hz kA 2 mm A 93% RH at 25 10 a 60 6/10/16/20/25/32/40/50/63 240/415 50/60 6 40 IP20 1/2/3/4 25 4000 10000 B/C/D 5 a 10 In attach 31 MB48 MB49
  • 25. Miniature Circuit Breaker www.meba.net MB50/MB51 Miniature Circuit Breaker Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Tropicalization 2 mm A Manufacturing Standards A Vac Hz kA 93% RH at 25 10 a 60 6/10/16/20/25/32/40/50/63 240/415 50/60 6 40 IP20 1/2/3/4 25 4000 10000 B/C/D 5 a 10 In attach Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MB50/ MB51 IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35 mm MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current ( TypeC ), 3 to 5 times rated current ( Type B), 10 to 20 times rated current ( Type D ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE CB ISO 9001-2000 awarded by the competent certification body,Meba isqualified in the manufacturing of the obj ect IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging is sure that withstand any adverse conditions during transport and handling to thewarehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days 32 MB51MB50
  • 26. www.meba.net Miniature Circuit Breaker Specification needs: MB52 Isolator Electrical Properties Type of Assembly Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization A Vac Hz kA 2 mm A Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MB52 Isolator IEC 60947-3 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35 mm The breaker have an operating window color display that shows the state in which it is ( connected or disconnected ). CE ISO 9001-2000 IEC 60947-3 standards Life, given by us to ensure that the life of the goods offered by atleast 5 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. We are surethe packaging withstand any adverse conditions during transport and handling to the cellars of the Company. Carton or Pallet In one of its sides the breaker is marked with the symbol permanent ink, year, month and batch. available Submit sample of the product offered 2 YEARS CIF CNF FOB 25 Days 93% RH at 25 10 a 60 6/16/20/25/32/40/50/63 240/415 50/60 0 40 IP20 1/2/3/4 25 4000 8000 / / attach Operation Indicator Window 33 MB52
  • 27. Miniature Circuit Breaker www.meba.net MB52 Miniature Circuit Breaker Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MB52 MCB IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35 mm The circuit breaker have an operating window color display that shows the state in which it is ( connected or disconnected ). MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current ( TypeC ), 3 to 5 times rated current ( Type B), 10 to 20 times rated current ( Type D ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE CB ISO 9001-2000awarded by the competent certificat ion body, Mebais qualified in themanufacturing of the object IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging issure that withstand any adverse conditions during trans port and handling to the warehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days A Vac Hz kA 2 mm A 93% RH at 25 10 a 60 6/10/16/20/25/32/40/50/63 240/415 50/60 6 40 IP20 1/2/3/4 25 4000 10000 B/C/D 5 a 10 In attach Operation Indicator Window 34 MB52
  • 28. MB52 Miniature Circuit Breaker Charcteristic Curve: 10000 5000 B type 2000 1000 500 200 100 50 0.2 0.1 20 10 5 2 1 0.5 0.05 0.02 0.01 0.005 0.002 0.001 Time(s) 0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In 10000 5000 C type 2000 1000 500 200 100 50 0.2 0.1 20 10 5 2 1 0.5 0.05 0.02 0.01 0.005 0.002 0.001 Time(s) 0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In 10000 5000 D type 2000 1000 500 200 100 50 0.2 0.1 20 10 5 2 1 0.5 0.05 0.02 0.01 0.005 0.002 0.001 Time(s) 0.5 1 2 3 4 5 7 1014 20 30 50 70 100 200 I/In Dimension(mm): 4P 3P 2P 1P 72 54 36 18 82 35 4576 www.meba.net Miniature Circuit Breaker 35 MB52
  • 29. www.meba.net Miniature Circuit Breaker MBB8-63-1P/2P Miniature Circuit Breaker MBB8-63-1P/ 2P mini circuit breaker Function: overload and short-circuit protection Poles: 1P, 2P, 3P, 4P Current rate: 1-63A The prod uct is mainly used in AC50/60HZ single-pole 230V or two, three, four-pole 400V circuit for overload and short-circuit protection as well as for unfrequenton-and-off switching electric equipment and lightingcircuit under normal condition. The product is suitable for industry, business, building, residence, etc. It is conformity with GB10963, IEC60898 standards. Applications: Features: Much higher short circuit breaking capacity. Dual-connection convenient for both standard busbar and conductor connection. Improved safetyof operatorsofferedby specialdesign ofterminals. Much longer service life thanks to energy storage operating mechanism. A variety of modular auxiliaries allows for easy and quick installation. Enclosure and functional parts made of advanced plastics with flame-retardant, heat-resistant and impulse-proofproperti es. Higher current-limiting capacity ensuring a cost-effective range of products. Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A. Tripping characteristics: B(3-5)In; C(5-10)In; D(10-15)In. No. of pole: 1p, 2p, 3p, 4p. Breaking capacity (see table1). Technical parameter: Rated current (A) 1~63 Pole Rated Voltage (V) Rated short-circuit breaking current (A) 1 2,3,4 230, 230/400 400 6000 6000 COS 0.7 0.7 MBB8-63-3P/4P Miniature Circuit Breaker MBB8-63-3P/4P mini circuit breaker Function: overload and short-circuit protection Poles: 1P, 2P, 3P, 4P Current rate: 1-63A The prod uct is mainly used in AC50/60HZ single-pole 230V or two, three, four-pole 400V circuit for overload and short-circuit protection as well as for unfrequenton-and-off switching electric equipment and lightingcircuit under normal condition. The product is suitable for industry, business, building, residence, etc. It is conformity with GB10963, IEC60898 standards. Applications: Features: Much higher short circuit breaking capacity. Dual-connection convenient for both standard busbar and conductor connection. Improved safetyof operatorsoffered byspecial designof terminals. Much longer service life thanks to energy storage operating mechanism. A variety of modular auxiliaries allows for easy and quick installation. Enclosure and functional parts made of advanced plastics with flame-retardant, heat-resistant and impulse-proofproperti es. Higher current-limiting capacity ensuring a cost-effective range of products. Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A. Tripping characteristics: B(3-5)In; C(5-10)In; D(10-15)In. No. of pole: 1p, 2p, 3p, 4p. Breaking capacity (see table1). Technical parameter: Rated current (A) 1~63 Pole Rated Voltage (V) Rated short-circuit breaking current (A) 1 2,3,4 230, 230/400 400 6000 6000 COS 0.7 0.7 36 MBB8-63-3P/4PMBB8-63-1P/2P
  • 30. MBB47 Miniature Circuit Breaker Features and Applications: The product ismainly used inAC50/60HZ single-pole230Vor two, three, four-poles 400Vcircuitfor overload and short-cir cuit protectio n as well as for unfrequent on-and-off switching electric equipment and lighting circuit under normal condition. It can be used in lighting and electric motor distribution system. It is characterized with novel structure, light weight, reli able and excellent performance, high breaking capacity. It is conformity with GB10963, IEC 60898 standards. Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century, Year, Month and Batch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBB47 IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35 mm MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current ( TypeC ), 3 to 5 times rated current ( TypeB ), 10 to 14 times rated current ( Type D ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE CB ISO 9001-2000 awardedby the competentcertification body, Mebais qualifiedin themanufacturing of theobject IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging is sure that withstand any adverse conditions duringtransport and handling to the warehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days A Vac Hz kA 2 mm A 93% RH at 25 50% RH at 40 -5 a 40 1/2/3/4/5/6/10/16/20/25/32/40/50/63 240/415 50/60 6 40 IP20 1/2/3/4 25 4000 8000 B/C/D Type B: 3 a 5 In Type C: 5 a 10 In Type D: 10 a 14 In attach www.meba.net Miniature Circuit Breaker 37 MBB47
  • 31. MBB100 Miniature Circuit Breaker Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization Operation Indicator Window A Vac Hz kA 2 mm A 93% RH at 25 10 a 60 63/80/100 240/415 50/60 10 40 IP20 1,2,3,4 63A/16 80A/25 100A/35 4000 8000 C/D Type C 5 a 1 0 In Type D 10 a 14 I n attach Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBB100 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230 V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35 mm The circuit breaker have an operating window color display that shows the state in which it is (connected or disconnected ). MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current ( TypeC ), 10 to 14 times rated current ( Type D) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE CB ISO9001-2000 awardedby the competent certificationbody,Meba isqualifiedinthemanufacturing ofthe object IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging issure that withstandany adverse conditions during transportand handling to the warehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days Miniature Circuit Breaker www.meba.net 38 MBB100
  • 32. Dimension(mm): 27 35 7.5 108 81 54 27 67 60 5 81 36 45 44 The over-current protection property: Ambient Temperature 40 2 -5~+40 Initial Status Test Current Expected Result Expected Result NOte Cold position Cold position Cold position Cold position 1.05In(In 63A) 1.05In (In 63A) 1.30In(In 63A) 1.30In (In>63A) 8.00In 12.00In t 1h t 2h t < 1h t < 2h t 0.2s t< 0.2s Non-release Non-release Release Release Non-release Non-release - - - - Carried out immedi-ately after previous test Current smoothlyrises to specified value within 5s MBB100 Miniature Circuit Breaker NC100H-1P Miniature Circuit Breaker Features and Applications: Character: high breaker capacity up to 10KA 40-100A current avaliable Poles: 1P, 2P, 3P, 4P. NC100H mini circuit breaker, mcb NC100H high breakingcapacity circuit breaker is usedfor AC50Hz or 60Hz, single pole 240V, 2, 3, 4 Poles 415, for protecting the circuit that overload and short circuit may take place. It can be used in lighting and electricmotor distribution system.Meanwhile it is applicableto an unfrequentswitchover the electric apparatus and lighting circuit under normal condition. Breaking capacity is up to standard of IEC947-7 10KA. Technical parameter: Rated current (A) Pole number (P) Rated voltage (V) Breaking capacity (A) 40, 50, 63, 80, 100 1 2, 3, 4 130 230/240 400/415 230/240 400/415 440 20000 10000 4000 20000 10000 6000 www.meba.net Miniature Circuit Breaker 39 MBB100 NC100H-1P
  • 33. NC100H-2P Miniature Circuit Breaker Features and Applications: NC100H high breaking capaci ty circuit breaker is used for AC 50Hz or 60Hz, single pole 240V, 2, 3, 4 Poles 415, for protecting the circuit that overload and short circuit may take place. It can be used in lighting and electric motor distribution system. Meanwhile it is applicable to an unfrequent switchover the electric apparatus and lighting circuit under normal condition. Breaking capacity is up to standard of IEC947-7 10KA. Character: high breaker capacity up to 10KA 40-100A current avaliable Poles: 1P, 2P, 3P, 4P. NC100H mini circuit breaker, mcb Technical parameter: Rated current (A) Pole number (P) Rated voltage (V) Breaking capacity (A) 40, 50, 63, 80, 100 1 2, 3, 4 130 230/240 400/415 230/240 400/415 440 20000 10000 4000 20000 10000 6000 NC100H-3P Miniature Circuit Breaker Features and Applications: NC100H high breaking capaci ty circuit breaker is used for AC 50Hz or 60Hz, single pole 240V, 2, 3, 4 Poles 415, for protecting the circuit that overload and short circuit may take place. It can be used in lighting and electric motor distribution system. Meanwhile it is applicable to an unfrequent switchover the electric apparatus and lighting circuit under normal condition. Breaking capacity is up to standard of IEC947-7 10KA. Character: high breaker capacity up to 10KA 40-100A current avaliable Poles: 1P, 2P, 3P, 4P. NC100H mini circuit breaker, mcb Technical parameter: Rated current (A) Pole number (P) Rated voltage (V) Breaking capacity (A) 40, 50, 63, 80, 100 1 2, 3, 4 130 230/240 400/415 230/240 400/415 440 20000 10000 4000 20000 10000 6000 www.meba.net Miniature Circuit Breaker 40 NC100H-3PNC100H-2P
  • 34. Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization A Vac Hz kA 2 mm A MBGV4 Miniature Circuit Breaker www.meba.net Miniature Circuit Breaker 93% RH at 25 50% RH at 40 -5 a 40 6/10/16/20/25/32/40/50/63 240/415 50/60 6 -5 a 40 IP20 1/2/3/4 25 4000 8000 B/C/D Type B: 3 a 5 In Type C: 5 a10 In Type D: 10 a 14 In attach Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBGV4 IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35 mm MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 14 times rated current ( Type D ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE CB ISO9001-2000 awardedby thecompetentcertification body,Meba isqualifiedin themanufacturing oftheobject IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging is surethat withstandany adverse conditions duringtransport and handlingto thewarehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days 41 MBGV4
  • 35. A Vac Hz kA 2 mm A MBH6 Miniature Circuit Breaker Protectio n and control of circuit against overload andshort circuit, inbuilding installation-such ashouses, offices, commerci al complex, motor system (D curve) and industrial installation-for switching,control,protection and regulationof electrical circuits. Also in switchgear panels, railway and marine application. Applications: Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century, Year, Month and Batch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization 93% RH at 25 50% RH at 40 -5 a 40 6/10/16/20/25/32/40/50/63 240/415 50/60 6 -5 a 40 IP20 1/2/3/4 25 4000 8000 B/C/D Type B: 3 a 5 In Type C: 5 a 10 In Type D: 10 a 14 In attach Miniature Circuit Breaker www.meba.net Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBH6 IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35mm MAGNETIC COIL:ensures the switching of short-circuit, speaking withinthe following ranges: 5to 10 times rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 14 times rated current ( TypeD ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectively dissipates theelectric arc that is generatedby the opening contacts of thetrigger mechanism in the presence of an overload or short circuit. CE CB ISO 9001-2000awarded by thecompetent certification body, Meba isqualified in themanufactu ring of the object IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receivingthe circuit breakers (breakers) , customers may perform the tests may be necessary toensure compliance with the technical specifications. The packaging issure that withstand any advers e conditions during transport and handling to the warehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days 42 MBH6
  • 36. A Vac Hz kA 2 mm A MBHVS-3D Isolator Specification needs: Applications: Capable of switch electric circuit with load Provide function of isolation Contact position indication Used as main switch for household and simiar installation Electrical Properties Type of Assembly Present Certificates Testing For Acceptance Packing DialCentury,Year, Monthand Batch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBHVS Isolator IEC 60947-3 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35mm CE ISO 9001-2000 IEC 60947-3 standards Life, given by us to ensure that the life of the goods offered by atleast 5 years. Before receiving the circuit breakers (breakers ), customers may perform the tests may be necessary to ensure compliance with the technical specifications. We are surethe packaging withstand any adverse conditions during transport and handling to the cellars of the Company. Carton or Pallet In one of its sides the breaker is marked with the symbol permanent ink, year, month and batch. available Submit sample of the product offered 2 YEARS CIF CNF FOB 25 Days 93% RH at 25 -5 a 40 6/16/20/25/32/40/50/63/80/100 240/415 50/60 4.5/6 -5 a 40 IP20 1/2/3/4 25 4000 8000 / / attach www.meba.net Miniature Circuit Breaker 43 MBHVS-3D
  • 37. MBHVS Isolator Specification needs: A Vac Hz kA 2 mm A Electrical Properties Type of Assembly Present Certificates Testing For Acceptance Packing DialCentury,Year, Monthand Batch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization 93% RH at 25 -5 a 40 6/16/20/25/32/40/50/63/80/100 240/415 50/60 4.5/6 -5 a 40 IP20 1/2/3/4 25 4000 8000 / / attach Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBHVS Isolator IEC 60947-3 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35mm CE ISO 9001-2000 IEC 60947-3 standards Life, given by us to ensure that the life of the goods offered by atleast 5 years. Before receiving the circuit breakers (breakers ), customers may perform the tests may be necessary to ensure compliance with the technical specifications. We are surethe packaging withstand any adverse conditions during transport and handling to the cellars of the Company. Carton or Pallet In one of its sides the breaker is marked with the symbol permanent ink, year, month and batch. available Submit sample of the product offered 2 YEARS CIF CNF FOB 25 Days Miniature Circuit Breaker www.meba.net 44 MBHVS Isolator
  • 38. www.meba.net Applications: MBHVS Isolator Capable of switch electric circuit with load Provide function of isolation Contact position indication Used as main switch for household and simiar installation Overall & Installation Dimensions: 18 36 54 72 MBHVS Miniature Circuit Breaker Protection and control of circuitagainst overload and short circuit, in building installation-such as houses, offices, commercial complex, motor system(D curve) and industrial installation-for switching, control, protectionand regulation ofelectrical cir cuits. Also in switchgear panels, railway and marine application. Applications: 86 36 45 67 Overall & Installation Dimensions: 17 34 51 68 82.5 37 47 66 76 45 Miniature Circuit Breaker 45 MBHVSMBHVS Isolator
  • 39. www.meba.net MBHVS Miniature Circuit Breaker Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Product Details Manufacturing Standards Tropicalization A Vac Hz kA 2 mm A Miniature Circuit Breaker Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBHVS IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35mm MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current (Type B), 10 to 14 times rated current (Type D ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE ISO 9001-2000awarded by thecompetent certificati on body, Mebais qualified in the manufacturing ofthe object IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging is sure that withstand any adverse conditionsduring transport andhandlingto the warehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days 93% RH at 25 50% RH at 40 -5 a 40 6/10/16/20/25/32/40/50/63 240/415 50/60 6 -5 a 40 IP20 1/2/3/4 25 4000 8000 B/C/D Type B: 3 a 5 In Type C: 5 a10 In Type D: 10 a 14 In attach 46 MBHVS
  • 40. www.meba.net Miniature Circuit Breaker MB162-1P/3P Isolator Miniature Circuit Breaker Specification needs: A Vac Hz kA 2 mm A Electrical Properties Type of Assembly Present Certificates Testing For Acceptance Packing DialCentury,Year, Monthand Batch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization 93% RH at 25 -5 a 40 63/80/100/125 240/415 50/60 3 -5 a 40 IP20 1/2/3/4 25 4000 8000 / / attach Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MB162 IEC 60947-3 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35mm CE ISO 9001-2000 IEC 60947-3 standards Life, given by us to ensure that the life of the goods offered by atleast 5 years. Before receiving the circuit breakers (breakers), customers may performthe tests may be necessary to ensure compliance with the technical specifications. We are surethe packaging withstand any adverse conditions during transport and handling to the cellars of the Company. Carton or Pallet In one of its sides the breaker is marked with the symbol permanent ink, year, month and batch. available Submit sample of the product offered 2 YEARS CIF CNF FOB 25 Days 47 MB162-1P MB162-3P
  • 41. MBDR047 Delay Relay Miniature Circuit Breaker www.meba.net MB162-1P/3P Isolator Miniature Circuit Breaker Applications: MB162 is major used as main switch in distribution box, control on or off for all branch switch. The product is applicable to circuit with rated voltage 230/400V AC, 50Hz for power distribution and motor operation as switching disconnector in both household & commercial and electric equipments installations. The product, free of maintenance,is suitable for use bynon-professionals. The product is switched on when the handle is at upper position. Overall and mounting dimensioned chart: 86 36 45 66 18 36 54 72 Application: MBDR047 is one kind of timer relay, used in distribution box with MCB, Isolator, Surge Arrester together. Rated voltage(V): 220-415. Overall & Installation Dimensions: 45.5 35 95 44.5 63.56 18 48 MBDR047MB162-1P/3P
  • 42. MBDPE06 Miniature Circuit Breaker Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization Operation Indicator Window Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBDPE IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230 V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve C Characteristic Intervention FOR RIEL DIN 35 mm The circuit breaker have an operating window color display that shows the state in which it is ( connected or disconnected ). MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current ( Type C ), 3 to 5 times rated current (Type B ), 10 to 14 times rated current ( Type D ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE CB ISO9001-2000awarded bythe competentcertification body, Meba is qualified in themanufacturingof theobject IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging is sure that withstandany adverse conditionsduring transport and handling to thewarehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days 93% RH at 25 10 a 60 1/2/3/4/6/10/16/20/25/32/40/50/63 240/415 50/60 6 -5 a 40 IP20 1/2/3/4 25 4000 10000 B/C/D 5 a 10 In attach A Vac Hz kA 2 mm A www.meba.net Miniature Circuit Breaker 49 MBDPE06
  • 43. MBJ6 Miniature Circuit Breaker Applications: Specification needs: www.meba.net Miniature Circuit Breaker A Vac Hz kA 2 mm A Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century, Year, Month and Batch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization 93% RH at 25 50% RH at 40 -5 a 40 6/10/16/20/25/32/40/50/63 240/415 50/60 6 -5 a 40 IP20 1/2/3/4 25 4000 8000 B/C/D Type B: 3 a 5 In Type C: 5 a 10 In Type D: 10 a 14 In attach Protectio n and control of circuit against overload and short circuit, in buildinginstallation-such as houses,offices, commercial complex, motor system(D curve)and industrial installation-forswitching, control, protectionand regulation ofelectrical circuits.Also in switchgear panels, railway and marine application. Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBJ6 IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35mm MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current ( Type C), 3 to 5 times rated current ( Type B ), 10 to 14 times rated current ( TypeD ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electricarc that isgenerated by the opening contacts ofthe trigger mechanism in the presence of an overload or short circuit. CE CB ISO9001-2000 awarded by the competentcertificat ion body, Mebais qualified inthe manufacturingof theobject IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving thecircuit breakers (breakers),customers may performthe tests maybe necessary toensure compliance with the technical specifications. The packaging is sure that withstand any adverse conditions during transport and handlingto the warehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days 50 MBJ6
  • 44. Specification needs: A Vac Hz kA 2 mm A Product Details Manufacturing Standards Tropicalization Electrical Properties Type of Assembly Operation Indicator Window Present Certificates Testing For Acceptance Packing Dial Century, Year, Month and Batch Catalog Shows Technical Warranty Place of Delivery Delivery Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBL7 Insulator IEC 60947-3 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35 mm The circuit breaker have an operating window color display that shows the state in which it is (connected or disconnected). CE ISO 9001-2000 IEC 60947-3 standards Life, given by us to ensure that the life of the goods offered by atleast 5 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. We are surethe packaging withstand any adverse conditions during transport and handling to the cellars of the Company.Carton or Pallet. In one of its sides the breaker is marked with the symbol permanent ink, year, month and batch. Available Submit sample of the product offered 2 YEARS CIF CNF FOB 25 Days 93% RH at 25 -5 a 40 6/16/20/25/32/40/50/63/80/100 240/415 50/60 3/4.5 -5 a 40 IP20 1/2/3/4 25 4000 8000 / / attach Applications: MBL7 Insulator Capable of switch electric circuit with load Provide function of isolation. Contact position indication. Used as main switch for household and simiar installation. www.meba.net Miniature Circuit Breaker 51 MBL7
  • 45. 5.5 35 45 44 60 76.5 80 17.5 MBL7 DPN MBL7 Series Miniature Circuit Breaker (hereinaft er referred to as breaker) is the company's own research and development of new products, theproducts arereliableand accurate protection features, high breaking capacity, smallsize, isan ideal replacement product. Circuit breaker is mainly applied to 50Hz/60HZ , rated voltage 230V, rated operating current to 40 A similar buildings and places of powerlines and electrical fac ili tie s, over-current protection devices, can beused for non-frequent on-off operati on. The circuit breaker in line with IEC60898: 1995, GBl0963-1999 "category for household and Currentprotection may place used circuitbreakers" and other standards. Applications: Shape and size of the installation of technology: Trip Type Thermal Trip Magnetic Trip B 1.13In 1.45In 3In 5In C 1.13In 1.45In 3In 10In Trip Time 1h <1h 0.1s <0.1s I1 I2 I3 I4 MBL7 Indicator Din Rail type LED Indicator, Neon Signal Lamp Specification: Low service duration, minimum power consumption Compact design in modular size, easy installation Rated voltage: 230V AC, 50/60Hz Colour: Red, green, yellow Connection terminal: Pillar terminalwith clamp 2 Connection capacity: Rigid conductor10mm Installation: - On symmetrical DIN rail - Panel mounting Illumination type: A. Illumination: LED - Max power: 0.6W - Service duration: 30,000 hours B. Illumination: Neon bulb - Max power: 1.2W - Service duration: 15,000 hours The DIN Rail type Modular Signal Lamp is applicable to circuit with rated voltage 230V AC, 50/60Hz for visual indication and signaling. Overall & Installation Dimensions: 18 44.6 26.35.5 91 35 45.5 70.5 Miniature Circuit Breaker www.meba.net 52 MBL7 DPNMBL7
  • 46. Specification needs: MBL7 DPN Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization Operation Indicator Window A Vac Hz kA 2 mm A Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBL7 IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve C Characteristic Intervention FOR RIEL DIN 35mm The circuit breaker have an operating window color display that shows the state in which it is (connected or disconnected). MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 3 to 10 times rated current ( Type C ), 3 to 5 times rated current (Type B), 10 to 14 times rated current ( Type D) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE CB ISO 9001-2000 awarded bythe competent certification body, Meba isqualified in the manufacturing of the object IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging issure that withstand any adverse conditions during transport and handling to the warehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days 93% RH at 25 10 a 60 6/10/16/20/25/32/40 240/415 50/60 6 -5 a 40 IP20 1P+N 25 4000 8000 B/C 3 a 10 In attach www.meba.net Miniature Circuit Breaker 53 MBL7 DPN
  • 47. www.meba.net Miniature Circuit Breaker C characteristic curve Trip current(X ln) Trip time 100 10 1 10 1 0.1 0.01 1 2 3 4 6 8 10 20 C MBL7 DPN Structural characteristics: Small size, limiting the effect of good, high breaking capacity, with 1P+N double break point, the polarization was Insulation to isolate, insync and connectedto the premise of breaking, N always first toconnect, after breakingboth to ensurethe protection of polar arcbreakingthe abilityto effectively protectand control lines and electrical equipment safety. Obvious conta ct with the locationof the stateof the instructions. -Type terminal block used to enhance, to facil ita te wir ing to 2 2 ensure that the wire 1mm to 16mm reliable connection. C characteristic curve Trip current(X ln) Trip time 100 10 1 10 1 0.1 0.01 1 2 3 4 6 8 10 20 C Normal working conditions and installation conditions: The normal working conditions: shall not exceed the limit of air temperature, the lower limit of +40 not below -5 , 24h+35 than average The location of the altitude than 2000mm. The location ofthe air relative humidity in the highesttemperature around 40 when does not exceed 50%, at lower temperatures can allow higherrelative humidity. The wetmonths mean maximum relative humidity,and nomore than 90 percent of the average minimum temperature does not exceed +25 . Andconsidering the temperature changes in product on the surface of the condensation. Pollution level 2. Installation conditions: Installation category two, three type. Breaker using standard guide installation. Circuit breaker should normally be mounted vertically, the handle up for access to current location. Installation should be no significant shock and vibration. Load capacity: Load Factor K Switch number(n) MCB capacity 1.10 1.00 0.90 0.80 0.70 1 2 3 4 5 6 7 8 Load Factor (I/In) Temperature( )Temperature of 1.50 1.40 1.30 1.20 1.10 1.00 0.90 -30 -20 -10 0 10 20 30 40 50 60 JAB7-40 and DO fuse or short-circuit the performance of NH 1.4 high selectivity of 1.4 KA, No functional 1.On electrical circuits from overload and short circuit protection. 2.Especially suitable for civilian use with a bracket of the lighting circuit protection.The centerline breaking, more secure. Rated Current (A) In 2 4 6 10 16 20 25 32 40 Model 54 MBL7 DPN
  • 48. MBL7 DPN Orders should be indicated when the product model, release type, the number of such. For example: JAB7-40 mini circuit breaker, rated current of 16A, release patterns for the C-type, 100 units, is expressed as JAB7-40-C16. Order Information: JAB7-40 of the rated current Characteristic curve of C GL fuse rated current (A) 10 16 <0.5 20 0.7 25 1.1 0.8 35 2.1 1.5 1.4 1.4 1.2 50 3.4 3.1 2.9 2.4 2.0 63 5.0 4.6 4.1 3.4 2.9 2.3 80 6.0 5.5 4.5 3.8 3.0 2.4 100 6 10 13 16 20 25 32 40 Fuse D01, D02, D03 performance: NH-00 fuse option: JAB7-40 of the rated current Characteristic curve of C GL fuse rated current (A) 6 10 13 16 20 25 32 40 16 <0.5 20 0.5 25 0.8 0.7 35 2.7 1.8 1.6 1.5 1.3 40 4.0 2.3 2.1 1.9 2.0 50 3.1 3.1 2.8 2.3 2.0 63 4.6 4.1 3.9 3.1 2.7 2.1 80 6.0 5.5 5.0 4.2 3.5 2.9 2.4 100 125 160 Overall & Installation Dimensions: 18 36 54 72 80 36 50 66 76 45 MBL8/MBL9 Miniature Circuit Breaker www.meba.net Miniature Circuit Breaker 55 MBL8MBL7 DPN
  • 49. Miniature Circuit Breaker www.meba.net Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization Operation Indicator Window A Vac Hz kA 2 mm A Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBL8/ MBL9 IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve C Characteristic Intervention FOR RIEL DIN 35mm The circuit breaker have an operating window color display that shows the state in which it is (connected or disconnected). MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( TypeB ), 10 to 14 times rated current ( Type D) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE ISO 9001-2000 awardedby thecompetent certific atio n body, Meba is qualified in the manufact uring of the objec t IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging issure that withstand any adverse conditions during transport and handlingto the warehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days 93% RH at 25 -5 a 40 6/10/16/20/25/32/40/50/63 240/415 50/60 6 -5 a 40 IP20 1/2/3/4 25 6000 20000 B/C/D 5 a 10 In attach Specification needs: MBL8/MBL9 Miniature Circuit Breaker 56 MBL9MBL8
  • 50. www.meba.net Miniature Circuit Breaker MBLPN/MBLPN2 Miniature Circuit Breaker Application: Protection and control of circuit against overload and short circuit, in building installation-such as houses, offices, commercial complex, motor system(D curve) and industrial installation-for switching, control, protection and regulation of electrical circuits. Also in switchgear panels, railway and marine application. Applicable to terminal and pin/fork type busbar connection Protection against both overload and short circuit High short-circuit capacity Specification needs: A Vac Hz kA 2 mm A Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century, Year, Month and Batch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization Manufacturer Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBLPN/ MBLPN2 IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230 V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35 mm MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( Type B), 10 to 14 times rated current ( Type D ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectively dissipates the electric arc that isgenerated by theopening contacts of thetrigger mechanism in the presence of an overload or short circuit. CE CB ISO 9001-2000awarded by thecompetent certification body, Meba is qualified in the manufacturing ofthe object IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving thecircuit breakers (breakers), customers may perform thetests may benecessary to ensure compliance with the technical specifications. The packaging issure that withstandany adverse conditions during transpo rt and handling to the warehouse of customers. In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days 93% RH at 25 50% RH at 40 -5 a 40 6/10/16/20/25/32/40/50/63 240/415 50/60 6 40 IP20 1/2/3/4 25 4000 8000 B/C/D Type B: 3 a 5 In Type C: 5 a 10 In Type D: 10 a 14 In attach 57 MBLPN MBLPN2
  • 51. Miniature Circuit Breaker www.meba.net Application: Protection and control of circuit against overload and short circuit, in building installation-such as houses, offices, commercial complex, motor system(D curve) and industrial installation-for switching, control, protection and regulation of electrical circuits. Also in switchgear panels, railway and marine application. Applicable to terminal and pin/fork type busbar connection Protection against both overload and short circuit High short-circuit capacity Specification needs: A Vac Hz kA 2 mm A Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century, Year, Month and Batch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization Manufacturer Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBLSN/ MBLSN2 IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230 V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35 mm MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( Type B), 10 to 14 times rated current ( Type D ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectively dissipates the electric arc that isgenerated by theopening contacts of the trigger mechanism in the presence of an overload or short circuit. CE CB ISO9001-2000awarded by thecompetent certification body, Meba is qualified in the manufacturing ofthe object IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customersmay performthe tests maybe necessary toensure compliance with the technical specifications. The packaging issure that withstandany adverse conditions during transp ort and handling to the warehouse of customers. In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days MBLSN/MBLSN2 Miniature Circuit Breaker 93% RH at 25 50% RH at 40 -5 a 40 6/10/16/20/25/32/40/50/63 240/415 50/60 6 40 IP20 1/2/3/4 25 6000 20000 B/C/D Type B: 3 a 5 In Type C: 5 a 10 In Type D: 10 a 14 In attach 58 MBLSN2MBLSN
  • 52. www.meba.net Miniature Circuit Breaker Specifications: Technical parameter: Max. AC Voltage Max. Interrupting Capacity Min. Current Rating Max. Current Rating Agency Recognition of Approvals Branch circuit protection Telecom power distribution Power conditioning Automatic control systems Power supplies Applications: Power conversion systems UPS equipment Control machines Generator sets MBQH1/MBQH2 Miniature Circuit Breaker Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always hold 100% rated current Wide range of time delays & operating currents Current limiting capabilities Ultra compact 26mm width module Din (13), (18) only, Mini-rail orDual mountable (13),(19) and(26) Trip indication with mid trip handle position Switch disconnector provides circuit isolation Reset possible immediately after overload 230/400 VAC 10kA rms 10A 1=125A 2, 3,1+N, 3+N=100A IEC 60947-2 SANS VC8036 SANS 156 Poles 1 2 3 1+N 3+N Voltage 230VAC 400VAC 400VAC 230VAC 400VAC KA 10 10 10 10 10 MCB Width(mm) 26 (1 Module) 52 (2 Module) 78 (3 Module) 52 (2 Module) 104 (4 Module) STD Pack 12 6 4 6 3 Rating(A) 10 15 20 25 30 35 40 45 50 63 70 80 100 125 10 15 20 25 30 35 40 45 50 63 70 80 100 10 15 20 25 30 35 40 45 50 63 70 80 100 10 15 20 25 30 35 40 45 50 63 70 80 100 10 15 20 25 30 35 40 45 50 63 70 80 100 Poles 1 3 Voltage 230VAC 400VAC KA 10 10 MCB Width(mm) 26 (1 Module) 78 (3 Module) STD Pack 12 4 Rating(A) 10 15 20 25 30 35 40 45 50 63 70 80 100 125 10 15 20 25 30 35 40 45 50 63 70 80 100 Poles 1 2 3 Voltage 230VAC 400VAC 400VAC KA 10 10 10 MCB Width(mm) 26 (1 Module) 52 (2 Module) 78 (3 Module) STD Pack 12 6 4 Rating(A) 63 125 63 100 63 100 QH Range Standard Circuit Breaker 10KA Curve 2 (Standard) mini and DIN Mounting, 57 MM Escutcheon Type QH-1(26) QH-2(26) QH-3(26) QH-N-2(26) QF-N-4(26) Standard Circuit Breaker 10KA Curve 1, mini and DIN Mounting, 57 MM Escutcheon Type QH-1(26) QH-3(26) Standard Circuit Breaker 10KA Curve 1, mini and DIN Mounting, 57 MM Escutcheon Type QH-S-1(26) QH-S-2(26) QH-S-3(26) 59 MBQH1 MBQH2
  • 53. Specifications: Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always hold 100% rated current Wide range of time delays & operating currents Current limiting capabilities Ultra compact 13, 18, 19, 26mm width module Din (13), (18) only,Mini-rail or Dual mountable(13), (19)and (26) Trip indication with mid trip handle position Switch disconnector provides circuit isolation Reset possible immediately after overload Technical parameter: Max. AC Voltage Max. Interrupting Capacity Min. Current Rating 230/400 VAC 5kA rms 0.5A 1=125A 3=100A IEC 60947-2 SANS VC8036 SANS 156 Max. Current Rating Agency Recognition of Approvals MBQF-D Miniature Circuit Breaker Branch circuit protection Telecom power distribution Power conditioning Automatic control systems Power supplies Applications: Power conversion systems UPS equipment Control machines Generator sets QF Range Special Supply Authority/Industrial Circuit Breaker-5KA Type QF-1(13) QF-3(13) QF-1(19) QF-3(19) QF-1(26) QF-3(26) Switch Disconnectors 6KA, mini and DIN Rail Mounting, 45 mm Escutcheon Type QF-1(13)-D QF-3(13)-D QF-1(18)-D QF-3(18)-D QF-1(26)-D QF-3(26)-D Poles 1 3 1 3 1 3 Voltage 230VAC 400VAC 230VAC 400VAC 230VAC 400VAC KA 5 5 5 5 5 5 MCB Width(mm) 13 (1 Module) 39 (3 Module) 19.5 (1 Module) 58.5 (3 Module) 26 (2 Module) 78 (3 Module) STD Pack 12 4 12 4 12 4 Rating(A) 10 15 20 25 10 15 20 25 10 15 20 25 30 35 40 45 50 63 10 15 20 25 30 35 40 45 50 63 10 15 20 25 32 40 45 50 63 70 80 100 125 10 15 20 25 32 40 45 50 63 70 80 100 Poles 1 3 1 3 1 3 Voltage 230VAC 415VAC 240VAC 415VAC 240VAC 415VAC KA 6 6 6 6 5 5 MCB Width(mm) 13 (1 Module) 39 (3 Module) 18 (1 Module) 54 (3 Module) 26 (2 Module) 78 (3 Module) STD Pack 12 4 12 4 12 4 Rating(A) 10 15 20 25 10 15 20 25 10 15 20 25 30 35 40 45 50 63 10 15 20 25 30 35 40 45 50 63 10 15 20 25 32 40 45 50 63 70 80 100 125 10 15 20 25 32 40 45 50 63 70 80 100 www.meba.net Miniature Circuit Breaker 60 MBQF-D