The CM-324 is an active infrared hands-free switch that can be used to automatically open doors. It has adjustable detection range and time delay settings and can be mounted in door frames or electrical boxes. The device connects to a power source and door operator system. It operates by detecting motion with an infrared sensor and activating a relay to trigger the door opening. Installation involves running wiring, setting dip switches for operating mode, mounting the unit, and adjusting the detection range and time delay.
Series 3171-MR are Vibration Switches with options as Manual Reset type and Remote Reset type .
Enclosure : Sealed Ingress Protection to IP 67 to BS EN60947-1 or,
Ingress Protection IP 67 to BS 5420
Set level range : 1 to 9g Peak (Horizontal Vibrations)
Contacts : Silver or, Gold
Mounting : Fix to vertical face with Reset Button at bottom.
NOTE : ac solenoids normally continuously rated
dc solenoids intermittent 25% rated i.e. (1 min. ON & 3 mins OFF)
Electrical Reset : Solenoid rating 48 watts maximum intermittent rating
Solenoid voltages 110, 240 ac or 24 dc
Series 3171-MR are Vibration Switches with options as Manual Reset type and Remote Reset type .
Enclosure : Sealed Ingress Protection to IP 67 to BS EN60947-1 or,
Ingress Protection IP 67 to BS 5420
Set level range : 1 to 9g Peak (Horizontal Vibrations)
Contacts : Silver or, Gold
Mounting : Fix to vertical face with Reset Button at bottom.
NOTE : ac solenoids normally continuously rated
dc solenoids intermittent 25% rated i.e. (1 min. ON & 3 mins OFF)
Electrical Reset : Solenoid rating 48 watts maximum intermittent rating
Solenoid voltages 110, 240 ac or 24 dc
Series 3171-MR are Vibration Switches with options as Manual Reset type and Remote Reset type .
Enclosure : Sealed Ingress Protection to IP 67 to BS EN60947-1 or,
Ingress Protection IP 67 to BS 5420
Set level range : 1 to 9g Peak (Horizontal Vibrations)
Contacts : Silver or, Gold
Mounting : Fix to vertical face with Reset Button at bottom.
NOTE : ac solenoids normally continuously rated
dc solenoids intermittent 25% rated i.e. (1 min. ON & 3 mins OFF)
Electrical Reset : Solenoid rating 48 watts maximum intermittent rating
Solenoid voltages 110, 240 ac or 24 dc
Series 3171-MR are Vibration Switches with options as Manual Reset type and Remote Reset type .
Enclosure : Sealed Ingress Protection to IP 67 to BS EN60947-1 or,
Ingress Protection IP 67 to BS 5420
Set level range : 1 to 9g Peak (Horizontal Vibrations)
Contacts : Silver or, Gold
Mounting : Fix to vertical face with Reset Button at bottom.
NOTE : ac solenoids normally continuously rated
dc solenoids intermittent 25% rated i.e. (1 min. ON & 3 mins OFF)
Electrical Reset : Solenoid rating 48 watts maximum intermittent rating
Solenoid voltages 110, 240 ac or 24 dc
In This PPT we are discussed about complete details of that product (Use,Operation, Technical details, Dimensions, Wiring, and etc..)
Please Support us and Follow our other Sites
https://automationtechplc2.blogspot.com
https://humidificationcontrol.blogspot.com
https://controlsandsystems.business.site
If you enjoyed this article, share it with your friends and colleagues
Greetings from power factor shop & SWITCHGEARS. At power POWER FACTOR SHOP & SWITCHGEARS,It is our endeavor to bring you state-of-the-art Products and Services for increasing the reliability & overall efficiency of your operation.
We are pleased to update you on Classification New AX Contactor range.
Digital Watchdog DWC-V4363TIRB User ManualJMAC Supply
Buy the Digital Watchdog DWC-V4363TIRB at JMAC Supply.
https://www.jmac.com/Digital_Watchdog_DWC_V4363TIRB_p/digital-watchdog-dwc-v4363tirb.htm?=slideshare
User manual for outdoor fixed installation led billboard displayMax Dan
User manual for outdoor fixed installation led billboard display
Features
Ultra thin and lightweight cabinet.
Various cabinet sizes can be available for different installation environment.
Beautiful and neat cabinet internal wiring.
In This PPT we are discussed about complete details of that product (Use,Operation, Technical details, Dimensions, Wiring, and etc..)
Please Support us and Follow our other Sites
https://automationtechplc2.blogspot.com
https://humidificationcontrol.blogspot.com
https://controlsandsystems.business.site
If you enjoyed this article, share it with your friends and colleagues
Greetings from power factor shop & SWITCHGEARS. At power POWER FACTOR SHOP & SWITCHGEARS,It is our endeavor to bring you state-of-the-art Products and Services for increasing the reliability & overall efficiency of your operation.
We are pleased to update you on Classification New AX Contactor range.
Digital Watchdog DWC-V4363TIRB User ManualJMAC Supply
Buy the Digital Watchdog DWC-V4363TIRB at JMAC Supply.
https://www.jmac.com/Digital_Watchdog_DWC_V4363TIRB_p/digital-watchdog-dwc-v4363tirb.htm?=slideshare
User manual for outdoor fixed installation led billboard displayMax Dan
User manual for outdoor fixed installation led billboard display
Features
Ultra thin and lightweight cabinet.
Various cabinet sizes can be available for different installation environment.
Beautiful and neat cabinet internal wiring.
“Trumen Technologies Pvt. Ltd.” is an ISO 9001:2015 certified ,Indian based Manufacturer and Exporters of Level and Pressure sensing instruments. We at Trumen is a team of professionals having years of experience in Level and Pressure Instruments manufacturing who understands what customer needs, and try to fulfill those requirements in appropriate time with best Quality.
We have wide range of CE certified product like Radar Level Transmitters, Ultrasonic Level ,Vibrating fork solid level switch, Vibrating fork liquid level switch, Admittance point level switch, Capacitance point level switch, Vibrating rod point level switch, Conductivity point level switch, Capacitive continuous level transmitter, Hydrostatic continuous level transmitter, etc.
Our products used in different industrial applications in various industries like Power and Water, Oil and Gas, Petrochemical, Mining and Metal, Food and Beverages, Cement ,Pharmaceutical and many more. We are regularly supplying our products to NTPC, IOCL,BPCL, BORL, Cipla, Lupin, Cadila healthcare, Praj High Purity Systems , Ultratech Cement, Shree Cement ,Jindal Group ,TATA, Asian Paints, Procter & Gamble, Hindustan Unilever Ltd, Kirloskar, Vedanta, Nestle, Pepsi, BASF, Novartis and many more.
We are regularly exporting our products to USA, UK, South Korea, Italy ,Thailand, Taiwan, UAE, Tanzania, Turkey ,Sri Lanka ,Saudi Arabia , Kuwait ,Malaysia, Sweden, Canada, Egypt , Brazil ,Singapore etc.
Address: 39, Mangal Nagar, Behind Sai Ram Plaza, Near Rajeev Gandhi Circle, AB Road, Indore, Madhya Pradesh 452001
Web: https://trumen.in/
Contact: 0731 497 2065
#VibratingForkLevelSensor
#VibratingForkLevelSwitch
#VibratingRodPointLevelSwitch
#Vibratingrodpointlevelswitchmanufacturersinindia
#Vibratingrodpointlevelswitchsupplierinindia
#TuningForkPointLevelSwitch
#AdmittancePointLevelSwitch
#RotatingPaddleLevelSwitch
#RadarLeveltransmitter
#LevelSensor
#solidlevelswitch
#powderlevelswitch
#limestone
#coalbunker
#PVCpowder
#levelinstruments
Regülatör Nedir?
Regülatör, alçak gerilim sistemlerinde enerjinin az veya çok gelmesi gibi dengesizlik durumlarında gerilim regülasyonunu sağlayan cihazlara verilen addır. Şebeke gerilimindeki dengesizlikleri düzenleyen regülatör, verimin düşmesini engeller.
Regülatör; frekans, güç, hız, basınç, gerilim ve akım gibi fiziksel büyüklükleri belirli bir düzeyde sabit tutar. Bunun dışında, regülatörler; elektronik koruma sistemi vasıtasıyla ayar dışındaki gerilimlerdeki düşme ve yükselmelerde de çıkış gerilimini elektromekanik olarak kesip oluşabilecek herhangi bir hasarı önler. Bu özelliği sebebiyle bilgisayar, faks makineleri, laboratuvar cihazları, ev ve aydınlatma sistemleri gibi şebekelerde regülatör kullanımına başvurulur.
Aşırı gerilim koruyuculuğu olmayan regülatörlerin aşırı gerilimlerde kullanılmaları önerilmez. Regülatörlerin en çok kullanıldığı sistemler trafo mesafelerinin çok uzak olduğu kırsal kesimler ile organize olmayan sanayi bölgelerinde yer alıp fabrikalarla aynı trafoyu kullanan sistemlerdir.
Regülatör Nasıl Çalışır?
Regülatör, genelde trafo ya da hassas yapılı varyak sistemlere seri bağlanarak çalışır. Güçlendirici görevi gören bu cihazlar gerilim dengelemesini ayarlarlar. Regülatör, temelde bir bulucu eleman, bir servo motor ve yayım organından oluşup karmaşık ve basit tiplere sahiptir. Yük tarafında oluşan bir kısa devrede regülatörler meydana gelen büyük akımların gitmesini sağlar.
Basit tip regülatörler ne yazık ki az önce bahsettiğimiz değişikliklere anında cevap veremezler, oluşabilecek bir düzensizliğe anında cevap verecek bir regülatör arandığı takdirde karmaşık tip regülatörler kullanılmalıdır. Şönt sezmeli seri regülatör olarak bilinen bu regülatörler küçük değişimlere dahi anında cevap verirler.
Regülatörü koruyan elemanlar ise regülatörden tamamen ayrıdır. Bu elemanlar çoğunlukla regülatör iş yapamaz duruma geldiğinde devreye girip sistemi ya da makineyi durdururlar. Regülatörlerde, şebekeden gelen alternatif akım elektronik servo devre ile ilk olarak trafoya sonra varyak’a aktarılır. Varyak’a bağlı olan motor ve motorun uçları servo devreye bağlanır; servo devre ise güç aldığı bir trafoya bağlıdır.
https://www.guvenis.com.tr/
Digital Watchdog DWC-V4567WTIR User ManualJMAC Supply
Buy the Digital Watchdog DWC-V4567WTIR at JMAC Supply.
https://www.jmac.com/Digital_Watchdog_DWC_V4567WTIR_p/digital-watchdog-dwc-v4567wtir.htm?=slideshare
Adjustable Range : 760 to 100 mm Hg Vacuum
Enclosure : IP 54, IP 65, IP 66 & Flameproof
Pressure Housing : Aluminium, Brass or, SS 316
Diaphragm : Neoprene, Teflon or, SS 316
Differential : Adjustable from 100 to 500 mm Hg
Max. Working Pressure : 12 bar
Switch type : 1 no. SPDT snap action micro switch
Switch rating : 5A, 250V AC Or, 0.2A, 250 V DC
Cable Gland : 3/8” Cable Entry
Calibration Scale : Optional
Pressure Port : 1/4” BSP (F)
Repeatability : 1% FSR
UiPath Test Automation using UiPath Test Suite series, part 3DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 3. In this session, we will cover desktop automation along with UI automation.
Topics covered:
UI automation Introduction,
UI automation Sample
Desktop automation flow
Pradeep Chinnala, Senior Consultant Automation Developer @WonderBotz and UiPath MVP
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
Transcript: Selling digital books in 2024: Insights from industry leaders - T...BookNet Canada
The publishing industry has been selling digital audiobooks and ebooks for over a decade and has found its groove. What’s changed? What has stayed the same? Where do we go from here? Join a group of leading sales peers from across the industry for a conversation about the lessons learned since the popularization of digital books, best practices, digital book supply chain management, and more.
Link to video recording: https://bnctechforum.ca/sessions/selling-digital-books-in-2024-insights-from-industry-leaders/
Presented by BookNet Canada on May 28, 2024, with support from the Department of Canadian Heritage.
Accelerate your Kubernetes clusters with Varnish CachingThijs Feryn
A presentation about the usage and availability of Varnish on Kubernetes. This talk explores the capabilities of Varnish caching and shows how to use the Varnish Helm chart to deploy it to Kubernetes.
This presentation was delivered at K8SUG Singapore. See https://feryn.eu/presentations/accelerate-your-kubernetes-clusters-with-varnish-caching-k8sug-singapore-28-2024 for more details.
GraphRAG is All You need? LLM & Knowledge GraphGuy Korland
Guy Korland, CEO and Co-founder of FalkorDB, will review two articles on the integration of language models with knowledge graphs.
1. Unifying Large Language Models and Knowledge Graphs: A Roadmap.
https://arxiv.org/abs/2306.08302
2. Microsoft Research's GraphRAG paper and a review paper on various uses of knowledge graphs:
https://www.microsoft.com/en-us/research/blog/graphrag-unlocking-llm-discovery-on-narrative-private-data/
DevOps and Testing slides at DASA ConnectKari Kakkonen
My and Rik Marselis slides at 30.5.2024 DASA Connect conference. We discuss about what is testing, then what is agile testing and finally what is Testing in DevOps. Finally we had lovely workshop with the participants trying to find out different ways to think about quality and testing in different parts of the DevOps infinity loop.
"Impact of front-end architecture on development cost", Viktor TurskyiFwdays
I have heard many times that architecture is not important for the front-end. Also, many times I have seen how developers implement features on the front-end just following the standard rules for a framework and think that this is enough to successfully launch the project, and then the project fails. How to prevent this and what approach to choose? I have launched dozens of complex projects and during the talk we will analyze which approaches have worked for me and which have not.
GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using Deplo...James Anderson
Effective Application Security in Software Delivery lifecycle using Deployment Firewall and DBOM
The modern software delivery process (or the CI/CD process) includes many tools, distributed teams, open-source code, and cloud platforms. Constant focus on speed to release software to market, along with the traditional slow and manual security checks has caused gaps in continuous security as an important piece in the software supply chain. Today organizations feel more susceptible to external and internal cyber threats due to the vast attack surface in their applications supply chain and the lack of end-to-end governance and risk management.
The software team must secure its software delivery process to avoid vulnerability and security breaches. This needs to be achieved with existing tool chains and without extensive rework of the delivery processes. This talk will present strategies and techniques for providing visibility into the true risk of the existing vulnerabilities, preventing the introduction of security issues in the software, resolving vulnerabilities in production environments quickly, and capturing the deployment bill of materials (DBOM).
Speakers:
Bob Boule
Robert Boule is a technology enthusiast with PASSION for technology and making things work along with a knack for helping others understand how things work. He comes with around 20 years of solution engineering experience in application security, software continuous delivery, and SaaS platforms. He is known for his dynamic presentations in CI/CD and application security integrated in software delivery lifecycle.
Gopinath Rebala
Gopinath Rebala is the CTO of OpsMx, where he has overall responsibility for the machine learning and data processing architectures for Secure Software Delivery. Gopi also has a strong connection with our customers, leading design and architecture for strategic implementations. Gopi is a frequent speaker and well-known leader in continuous delivery and integrating security into software delivery.
UiPath Test Automation using UiPath Test Suite series, part 4DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 4. In this session, we will cover Test Manager overview along with SAP heatmap.
The UiPath Test Manager overview with SAP heatmap webinar offers a concise yet comprehensive exploration of the role of a Test Manager within SAP environments, coupled with the utilization of heatmaps for effective testing strategies.
Participants will gain insights into the responsibilities, challenges, and best practices associated with test management in SAP projects. Additionally, the webinar delves into the significance of heatmaps as a visual aid for identifying testing priorities, areas of risk, and resource allocation within SAP landscapes. Through this session, attendees can expect to enhance their understanding of test management principles while learning practical approaches to optimize testing processes in SAP environments using heatmap visualization techniques
What will you get from this session?
1. Insights into SAP testing best practices
2. Heatmap utilization for testing
3. Optimization of testing processes
4. Demo
Topics covered:
Execution from the test manager
Orchestrator execution result
Defect reporting
SAP heatmap example with demo
Speaker:
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
Smart TV Buyer Insights Survey 2024 by 91mobiles.pdf91mobiles
91mobiles recently conducted a Smart TV Buyer Insights Survey in which we asked over 3,000 respondents about the TV they own, aspects they look at on a new TV, and their TV buying preferences.
Connector Corner: Automate dynamic content and events by pushing a buttonDianaGray10
Here is something new! In our next Connector Corner webinar, we will demonstrate how you can use a single workflow to:
Create a campaign using Mailchimp with merge tags/fields
Send an interactive Slack channel message (using buttons)
Have the message received by managers and peers along with a test email for review
But there’s more:
In a second workflow supporting the same use case, you’ll see:
Your campaign sent to target colleagues for approval
If the “Approve” button is clicked, a Jira/Zendesk ticket is created for the marketing design team
But—if the “Reject” button is pushed, colleagues will be alerted via Slack message
Join us to learn more about this new, human-in-the-loop capability, brought to you by Integration Service connectors.
And...
Speakers:
Akshay Agnihotri, Product Manager
Charlie Greenberg, Host
1. CM-324 Series
Active Infrared “Hands-Free” Switch
Installation Instructions
BY CAMDEN
Section 1: General Description
Sure-Wave™ hands-free” switch is an active infrared
device designed for use with an automatic door operator
or other access control product.
Applications include low-energy doors, drive-up windows,
health-care facilities, manufacturing, etc.
The assembly will fit in a variety of locations from a
1 3/4” door frame to a 1-gang or 2-gang electrical box.
Various size surface mounting boxes are also available
from Camden.
Three standard face plate widths are available:
CM-324: 2 ¾” x 4 ½” polycarbonate or stainless steel,
fits on single gang electrical boxes.
CM-324/ N: 1 ¾” x 4 ½” polycarbonate or stainless
steel, fits 1 ¾” door frames or our CM23D Jamb box.
CM-324/ W: 4 ½” x 4 ½” polycarbonate or stainless steel,
fits on single gang, double gang or 4 x 4 electrical boxes.
All faceplates may be ordered up with a plain face (/1),
with the waving hand symbol (/2), or with the waving
hand symbol and words: WAVE TO OPEN (/3).
Section 2: Installation
Mounting
Sure-Wave™ may be mounted in door jambs, single or
double gang electrical boxes, and 4 x 4 boxes.
NOTE: The sealing gasket (included) is recommended for
outdoor or wet locations. If using with Automatic doors install in
accordance with ANSI A156.10 / A156.19. Select from one of
the following three mounting subsections:
SINGLE GANG ELECTRICAL BOX: CM-324
1a – If using an in-wall box ensure the box is plumb and
square, and flush with the wall surface. (See Diagram 1)
1b – If using a surface box, ensure it is secure & plumb.
2 – Bring your 4-conductor wire through the back or
side of the enclosure and leave approximately 6” tail for
wiring connection.
3 – Make the electrical connections to the device
according to the wiring section (following).
4 – Using the dip switch located on the end of the unit, set
the operating mode. (See Section 4)
5 – Attach the unit to the enclosure using the two #6-32
screws provided.
6 – Apply power and adjust range and time delay via the
potentiometers on the front of the unit. (See Section 4 for
adjustments)
7 – Attach the faceplate to the unit using the two black
#6-32 x 3/8 machine screws or tamperproof screws.
Do not overtighten!!
Diagram 1 - Proper Box Installation
Rough Wall
Finish
Recessed
Box
Unaligned
Box
Wall
Wall Box
Flush
Smooth
Wall Finish
Page 1 to 4
2. CM-324 Active Infrared “Hands-Free” Switch Installation Instructions
2-GANG (or 4x4) ELECTRICAL BOX: CM-324W
1a – If using an in-wall box ensure the box is plumb and
square, and flush with the wall surface. (See Diagram 1)
1b – If using a surface box, ensure it is secure & plumb.
1c – If using a 4 x 4 box, ensure the box is plumb and
square, and flush with the wall surface, then attach the
metal adaptor plate (included in the CM-324W package)
to the box using appropriate fasteners.
2 – Bring your 4-conductor wire through the back or side
of the enclosure and leave approximately 6” tail for wiring
connection.
3 – Make the electrical connections to the device
according to the wiring section (following).
4 – Using the dip switch located on the end of the unit,
set the operating mode. (See Section 4)
5 – Attach the unit to the enclosure using the two #6-32
screws provided.
6 – Apply power and adjust range and time delay via the
potentiometers on the front of the unit. (See Section 4 for
adjustments)
7 – Attach the faceplate to the unit using the two black
#6-32 x 3/8 machine screws or tamperproof screws.
Do not overtighten!!
DOOR FRAME: CM-324N
1a – If mounting directly in a 1¾” wide aluminum jamb,
make a cutout in the door frame at the intended location
as per Diagram 2. (See Diagram 2 on page 4)
Drill and tap two mounting holes as shown.
1b – If mounting the unit in our CM-23d deep jamb box,
first mount the jamb box according to the instructions
packaged with the enclosure. Using the CM-23D as a
guide, drill a wire access hole through the jamb to fish the
wiring through.
2 – Bring your 4-conductor wire through the back or side
of the enclosure (or Jamb) and leave approximately 6” tail
for wiring connection.
3 – Make the electrical connections to the device
according to the wiring section (following).
4 – Using the dip switch located on the end of the unit, set
the operating mode. (See Section 4)
5 – Attach the unit to the enclosure or jamb using the two
#6-32 screws provided.
6 – Apply power and adjust range and time delay via the
potentiometers on the front of the unit. (See Section 4 for
adjustments)
7 – Attach the faceplate to the unit using the two black
#6-32 x 3/8 machine screws or tamperproof screws.
Do not overtighten!!
Wiring
CAUTION: Do not apply power to the unit until all second-
ary wiring is complete, and dip-switches have
been set.
The CM-324 can be powered from 12 or 24 volts, AC or
DC. Connect the two Red wires, (which are non-polarity
sensitive) to the power source.
The output is a form C relay. N.O is Blue, N.C. is Violet,
and Common is Green. Selecting the correct output is also
dependant on the operating mode chosen. (See Section
4) Most applications will utilize the N.O. and Common
terminals.
Section 3:
Applications & Set-up Applications
See Diagram 3 for the location of the Dip switches.
Switch 1 – Normal Mode/Fail-Safe Mode
Choose Normal Mode if you wish the N.O. contact to remain
open if the power were to fail. This is the factory setting.
Choose Fail-safe Mode if you wish the contacts to close
upon power fail. Move the Dip switch to OFF position, and
wire your device to the Common and N.C. wires.
Switch 2 – Time Delay Mode/Toggle Mode
Factory setting is Time Delay (Sense) mode, whereby the
contact closure will be adjustable from 1 – 5 seconds
using the Time Delay Potentiometer.
In Toggle (or Switch) mode, when the CM-324 is activated
once, the relay will stay energized until it is activated once
again. (The adjustable timer is inactive in this mode)
Photo Eye
Red LED
Time Delay
Adjustment
Dip Switch
Red
Red
Blue
Green
Violet
12-24V
Power
N.O.
OM
N.C.
Range
Adjustment
Wiring Pigtail
CM-324
Diagram 3 - Location of Adjustments
Page 2 to 4
3. CM-324 Active Infrared “Hands-Free” Switch Installation Instructions
Switch 3 – LED On/LED Off
This switch disables the LED,
should this feature be desired.
Factory setting is ON.
Once the Dip switches have been
set, and the unit is installed in the
frame or enclosure, apply power to
the unit and observe operation.
Set both potentiometers to
minimum setting initially (fully
counter-clockwise).
See Diagram 3 for location.
Adjust the range potentiometer
by turning the pot in a clockwise
manner, and passing your hand
in front of the unit. Rotate the pot
until the desired range is obtained.
See Diagram 4 for patterns.
Next, adjust the time delay
potentiometer by turning clockwise
until the desired time delay is
obtained. It is sometimes beneficial
to leave this adjustment set to minimum and utilize the
time delay on the door operator, if present.
NOTE: Timer is non-functional in Toggle Mode.
Install the faceplate using the screws provided.
Do not overtighten!!
OPTIONAL – Apply the included Wheelchair logo to the
frame or wall at desired location. See Diagram 5 on page 4.
Do not apply directly to the faceplate!!
If using this product with an Automatic Door, proceed to
Section 4 for System Inspection Instructions.
Section 4:
System Inspection Instructions
After the Installation and operational check of the system:
1. Place warning label on the door (as per ANSI A156.10
or A156.19 guidelines). This will advise the person
entering the swing side zone that the door will move.
2. Instruct the owner on door system operation and how
to test it. This should be checked on a daily basis.
3. Instruct the owner on what to do if the door or any of
its components become damaged.
4. Strongly recommend to the owner that the complete
entry be inspected twice a year as part of the service
agreement.
Section 5: Technical Data
Section 6: Warranty
Camden Door Controls guarantees the Sure-Wave™ to
be free from manufacturing defects for 3 years from date
of sale.
If during the first 3 years the CM-324 fails to perform
correctly, it may be returned to our factory where it will be
repaired or replaced (at our discretion) without charge.
Except as stated herein, Camden extends no warranties
expressed or implied regarding function, performance or
service.
Model CM-324
Body Size 4” L x 1” W x 1 ½” Deep
Mounting 2 x #6-32 MS
Faceplates Sizes Jamb, 1-gang, & 2-gang
Technology Infra-Red with Coded Modulated Carrier
Security Automatic Self-changing ID
Operating Modes Pulse (sense) / Toggle
Operating Temp -4 to +153 ºF (-20 to +85 ºC)
Operating Voltage 12-24 Volts, AC/DC ± 12%
Current Draw 50 - 60 mA.
Response Time 100 ms.
Activation Range:
Minimum
Maximum
1” – 3”
1” – 26”
Relay Output Form C (SPDT)
Relay Contact Rating 5 amps @ 30 VDC
Output Type Normal or Fail-Safe
Connections 11” 22 AWG Leads
Time Delay 1 to 5 Seconds
Electrical Life 100,000 Operations@ Rated Capacity
500,000 Operations@ ½ Rated Capacity
Door
Frame
25mm
1"
CM-324/N3
Questions? Call us toll-free at 1-877-226-3369
Diagram 4
Wheelchair
Sticker
Placement
Page 3 to 4
4. DISCOVER THE BEST IN DOOR ACTIVATING
AND LOCKING PRODUCTS!
www.camdencontrols.com
Toll Free: 1.877.226.3369
Push Buttons Key Pads Strikes Magnetic Locks Key Switches Relays & Timers Access Control
CM-324 Active Infrared “Hands-Free” Switch Installation Instructions
CM-324-Rev1
Revised: 03/18/2011 2:30 PM
Part No: 40-82B100
Diagram 2
Jamb Cutout Dimensions
1’0’ 2’ 3’
3”
(75mm)
26”
(660mm)
Diagram 5
Adjustable Range Settings
73mm
7/8"2
32mm
1/4"1
83mm
9/32"3
Drill & Tap
6-32 (2 holes)
Page 4 to 4