9953330565 Low Rate Call Girls In Rohini Delhi NCR
B.TECH P1 - IBS Score
1. Compliance ofBuilding Components’Sizes with MS1064
Component : number Sizes (mm)
Preferred sizes according to
MS1064 (✓/No)
Beam
B1, B4, B5, B6 : 56 300 x 600 ✓
B2 : 16 600 x 600 ✓
B3 : 16 400 x 600 ✓
Percentage of sizes of components based on MS1064 100%
Column
C1, C2, C3, C4 : 48 300 x 300 ✓
Percentage ofsizes ofcomponents based on MS1064 100%
Wall
E1 – E17 : 200 150 ✓
Percentage ofsizes ofcomponents based on MS1064 100%
Slab
S1- S6 : 86 150 ✓
Percentage of sizes ofcomponents based on MS1064 100%
Door
D1: 36 2100 x 1000 ✗
D2 2100 x 2000 ✗
Percentage ofsizes ofcomponents based on MS1064 0%
Window
W1 : 12 (L-shape) ✗
W2 : 6 450 x 900 ✗
W3 : 12 1200 x 1200 ✓
Percentage ofsizes ofcomponents based on MS1064 40%
2. IBS Score
Elements
Area (m2) or
Length (m) or
IBS
Factor
Coverage IBS Score
Part 1
Precastconcrete slab + Precast
Concrete Column and Beam
(Ground, 1st and 2nd Floor)
673.20 1.0 0.75 1.0 x 0.75 x 50 = 37.5
Rooftruss using prefab roof
truss
224.40 1.0 0.25 1.0 x 0.25 x 50 = 12.5
Total 50
Part 2
External and Internal wall using
precastconcrete panel
386.85 1.0 1.00 1.0 x 1.00 x 20 = 20.0
Total 20
Part 3
Wall sizes based on MS1064 100% 4
Slab sizes based on MS1064 100% 4
Column based on MS1064 100% 4
Repetition ofFloor Height 100% 2
Repetition ofVertical Structural
Floor Layout
100% 2
Repetition ofHorizontal
Structural Floor Layout
100% 2
Prefab Toilet Units 100% 1
Prefab Refuse Chute 100% 1
PrecastBalcony 100% 1
Total 21
Total IBS Score 91
3. Conclusion
The extensive use ofprecastand prefabricated building components, repetition ofstructural layout as well
as the utilization ofstandardized components based on MS1064 in this building lead to a high total IBS
score of91 over 100, indicating a well-structured assessmentsystem in this project. It has obtained the
maximum points of50 and 20 for part 1 and 2 respectively. However, the compliance ofdoor and window
sizes with MS1064 is overlooked. To further improve the score in part3, W2 (450mm x 900mm) can be
changed to 600mm x 1200mm, following the preferred size stated in MS1064. Similar amendmentcan be
done for other doorsets and windowsets.