Getinge Terminal Sterilizers
Securing optimal processing of
packaged pharmaceuticals
Getinge Terminal Sterilizers | 
From concept to compliance
As a world leader in the field of washing and
sterilization, Getinge draws from over 100 years of
accumulated knowledge to provide the advanced
equipment, application skills, documentation, regulatory
know-how and support services you can depend on
from “concept to compliance”.
Pharmaceutical competence
Our long-term involvement with washing and sterilization
procedures has made us intimately familiar with
pharmaceutical production methods. Therefore we are
well aware of the challenges associated with the sterile
treatment of liquids, solids and the numerous types of
delivery systems available today.
The complete production chain
Getinge can take care of virtually all your needs in the
sterile processing of pharmaceuticals.
We supply:
• Water pretreatment systems
• Water distillation systems
• Steam generators
• Component and equipment washers
• Component and equipment sterilizers
• Closure processing systems
• Terminal sterilizers
• Isolators for sterility testing and processing
• Installation design support services
•	
Testing, commissioning and qualification
(FAT/SAT, IQ/OQ)
• Training and after-sales support
Optimizing economy
As Getinge supplies virtually everything from concept to
compliance, we can optimize the lifecycle economy for
your sterile processing equipment. Dealing with just one
competent company will save you time, effort and costs.
Since all our equipment is compatible and has common
documentation, rapid system integration and installation
are assured. And equipment that is built to meet the
world’s highest standards of quality and safety means
maximal uptime and a safer working environment.
Pharmaceutical production puts stringent demands on sterile processing equipment
in terms of maximal uptime, high performance and optimal production capacity. And,
of course, proper safeguards that exceed industry standard practice should minimize
microbial and particulate contamination.
| Getinge Terminal Sterilizers
Gentle but effective
product sterilization
Getinge develops, manufactures and supplies completely integrated washing and sterilization
systems for use within the life sciences.
GEV/GEC sterilization kills the toughest microbes but is gentle enough to protect the integrity
of components, products and packaging. A wide range of sterilization cycles increases their
application versatility.
Getinge GE Steam Sterilizers can also be used to sterilize products in ampoules or vials.
RECEPTION
UTILITIES DISTRIBUTION BARRIER
A
B
Getinge Ventilator Terminal Sterilizers
(GEVs)* are designed primarily for sterilizing
products that must be dry and ready for
further handling immediately after the
cooling phase.
Standard chamber volume:
0.5 to 10.1 m³.
* GEV Terminal Sterilizers use steam/air mixtures for sterilization.
Getinge Circulating Water Terminal
Sterilizers (GECs) are primarily intended for
sterilizing large volumes of liquids in sealed
glass or plastic containers.
Standard chamber volume:
0.5 to 20.0 m³.
STERILE ZONE
CLEAN ZONE
BARRIER BARRIER
A			 GEV B			 GEC
Pharmaceutical production
Getinge Terminal Sterilizers |
Safeguarding your investment
Robotic welding is used wherever possible to provide a high
level of consistency and accuracy.
A sterilization system represents a large capital
investment. Therefore Getinge takes measures to ensure
that our GEV/GEC Terminal Sterilizers provide true value
with regard to design, performance and lifecycle economy.
Strong on safety
Getinge sterilizers are designed and built to meet the
world’s highest standards of quality and safety. Produc­tion
facilities are ISO 9001-certified and all appropriate inter­
na­­tional regulations for safety, pressure vessels and the
environment are rigorously followed. A risk assess­ment is
performed on all products, focusing on personnel safety.
Leading-edge construction
The production of Getinge sterilizers involves leading-edge
construction techniques and use of the highest-grade
materials. Accurate laser cutting minimizes the number of
construction welds. Robotic welding provides a level of
weld consistency superior to manual techniques and elimi­
nates defects in welded seams. Robotic grinding systems
reduce sites of potential corrosion and allow easy cleaning.
And the unique sectional jacket design provides rigidity,
allows visual inspection of all welds and reduces weight.
Advantages of sliding doors
The sliding doors of GEV/GEC Terminal Sterilizers offer
a number of advantages over hinged doors. They are
cleaner, safer and simpler. Hinges require grease which
can collect dirt. Sliding doors are safe since the hot inner
surface is not exposed when the door is open. Space
is maximized as the door does not swing outward, and
there is free access to the chamber for loading/unloading.
Widest range of chamber sizes
Getinge has the widest range of chamber sizes
available from any manufacturer to meet the needs
of all common applications. Standard chamber sizes
range from 0.5 to 20 m3
. Customized chamber sizes
are available on request.
Regulatory issues
Getinge closely follows industry trends, practices,
guidelines and regulatory requirements. Additionally we
actively participate in working groups and committees
working to refine these requirements.
GAMP | cGMP | BPE2005 | MCA | ISPE BASELINE GUIDES
FDA | EN46002 | ISO9000 | 21CFR Part 11
All sterilizers are manufactured according to the guide-
lines or standards relating to the intended applications
and the country of installation.
Protecting the environment
Special processes have been developed for safe disposal
of discarded waste for environmental protection. Options
are also available to reduce cooling water consumption by
up to 75%.
Getinge sterilizers are built in state-of-the-art production facilities.
 | Getinge Terminal Sterilizers
Infection Control | 
1.	
Batteries of dense heat exchangers
fabricated from seamless stainless-
steel tubing power the GEV’s rapid
cooling. GMP compliant with no
connections inside the chamber.
2.	
Sectional internal liners control
GEV airflow and consequently
temperature distribution. Each zone
is equipped with fan, heat exchanger
and piping.
3.	
A custom designed stainless steel
centrifugal fan delivers high GEV
airflow rates. Driven via a unique
mechanical seal by an electric motor.
4.	
Unique distribution plate of the GEC
ensures constant and uniform water
cascade over the product for uniform
heating and cooling.
5.	
A powerful sanitary centrifugal pump
delivers massive flow rates to the
GEC cascade system. Efficient plate
heat exchangers heat and cool the
circulating water.
6.	
The doors of Getinge sterilizers are
the cleanest, safest and simplest on
the market.
7.	
The unique sectional jacket adds
strength and rigidity to the chamber,
and robotic welding eliminates
defects. The resulting construction
ensures a long product lifecycle to
safeguard your capital investment.
8. T
op-quality piping and components
are assembled to the highest 		
standards.
1
8
2
3 4
5 6
7
Features that satisfy your
processing needs
Versatile programs
Program combinations are designed to suit particular
applications of GEV or GEC models, whether for
sterilizing different types of product or performing single-
product sterilization cycles. Sterilizers that incorporate a
vacuum pump provide even more versatile operation.
With GEV models, the products in the chamber may
be heated with hot air at the start of a cycle before
steam is used in order to minimize condensation and
shorten the drying phase.
The patented GEV “Zone Control™” feature allows
validated processing of part batches, allowing
production flexibility while reducing validation effort.
With GEC models, temperature overdrive is used at
the start of a cycle to shorten both the heating phase
and the total process cycle.
Numerous design options
Just a few design options that reflect Getinge’s
reputation as a flexible and innovative supplier are:
• A wide range of chamber capacities.
• Single-door or double-door, pass-through models.
• 
Dual sequencing controls at both ends of a pass-
through model with master control panels if required.
• Service area on either side of the chamber.
• 
Clean steam supply from a built-in generator and/or
external source.
• 
Sterilizer mounted in either a cabinet, recessed be-
tween two walls, or recessed in a cabinet within one wall.
• 
A range of loading systems, e.g. powered roller
conveyors, trolleys, pallet trucks and the Getinge
RAT system.
• 
Models that can be installed directly on a floor for
loading with racks and transfer trolleys, or pit-mounted
models for convenient roll-in, roll-out load handling.
Complete loading/unloading solutions
Getinge’s extensive choice of high-grade stainless steel
loading systems range from basic product handling items
such as sliding shelves to highly automated loading/
unloading units. These are ergonomically designed for
safe, simple and smooth product handling. Both standard
and custom-built systems are provided to meet the
demands of diverse material-handling challenges. The
wide variety of loading/unloading equipment includes:
• Shelf racks and trays
• Stackable shelves
• Various rail systems
• Loading trolleys
• Roller conveyors
Handling and movement of heavy production loads
can be difficult and hazardous. Getinge can provide
complete production logistics systems, assisted by our
specialist partner, Compliant Logistics. See page 14 for
more details.
GEV processing results in dry cool products. It suits containers with
closures not mechanically held in place and blister packs.
The features built into Getinge GEV/GEC Terminal Sterilizers allow the user to define
and program the processing parameters best suited to particular types of packaged
pharmaceuticals. Steam/air mixtures in the GEV Terminal Sterilizer are used to sterilize
products that need to be dry after the cooling cycle, whereas cascading water in the
GEC Terminal Sterilizer is used for the rapid sterilization of bulk liquids.
 | Getinge Terminal Sterilizers
In keeping with Getinge’s policy of continuous product
and application development, a Sterilization Technology
Center is available for customers who need to define the
correct processing conditions for particular products.
Sterilization Technology Centers are located in
Japan, Sweden, the USA and the UK. Each center is
equipped with specially designed sterilizers that allow
programming of a wide range of process cycles and
printout of relevant documentation.
Conduct your own test runs
The Sterilization Technology Center is the place to
come and discuss your application challenges with
our experienced personnel. You can conduct test runs
on your own products and packaging to define the
sterilization parameters best suited to them. Scale-up
runs can also be carried out to test the suitability of
selected cycles prior to final decision-making.
Customer programming via the control system
interface also makes it possible for you to make changes
to each phase of the process cycle after a sterilizer has
been installed in your production facilities.
Preventing deformation
GEC Sterilizers provide two ways of preventing
deformation of plastic containers: the use of air
overpressure, independently controlled during the
heating and cooling phases, and, when required, the
use of special loading trays developed by Getinge.
GEV Terminal Sterilizers are gentler on products and
Enabling you to achieve
optimal processing
GEC processing enables high-volume throughput of bulk liquids and
does not deform flexible plastic containers.
10 | Getinge Terminal Sterilizers
Partial pressures of air and steam add up to the total pressure in a sealed
container.
One can adjust the heating and cooling rates to optimize the process cycle
for the best production economy/utility consumption.
Steam
Air
Total pressure
Bar abs.
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
˚C
40 60 80 100 120 140
20 10 20 30 40 50 60 min.
1.5
2.0
2.5
3.0
3.5
4.0
Bar
abs.
20
40
60
80
100
120
Chamber
temp.
Load
temp.
Chamber
press
°C
packaging that tend to be pressure-sensitive. Air
overpressure is used during the heating and cooling
phases, but only to prevent plastic containers from
deforming or closures from being displaced.
The GEV sterilizer incorporates programs that ensure
PVC containers are clear at the end of the cooling cycle.
Accurate pressure-temperature link
The liquid being sterilized, fill volume, container material
style, and the type of closure all determine the correct
temperature and pressure to be used during the process
cycle. These parameters are independently controlled
in GEV/GEC units so it is easier to achieve the required
processing conditions. Furthermore, excellent pressure
control is provided by accurately linking any change in
pressure closely to product temperature throughout the
complete process cycle.
A combination of good heat transfer and optimized
cooling for different packaging offered by GEV/GEC
Terminal Sterilizers enables rapid processing to be
defined for a wide range of products.
Own design team
We have our own team of design and planning experts
that creates installation drawings for individual machines
as well for complete washing and sterilization systems,
along with utilities that match process and production
needs. So once you have chosen the sterilizer or system
that satisfies your production needs, we can help you to
get it up and running as soon as possible.
Getinge Terminal Sterilizers | 11
Dry products from Getinge GEV Terminal Sterilizers
are ready for immediate handling and further processing
such as such as inspection, labeling, packing, etc.
GEV Product Sterilizers are also ideal for products,
e.g. blister-packed products and sophisticated delivery
devices, that can be distorted or damaged by standard
steam processes.
Moisture-sensitive materials also benefit from GEV
process and the variable and independent regulation of
air overpressure makes it possible to design sterilization
programs for a range of pressure-sensitive products.
Alternative cycles, including vacuum cycles can also
be incorporated in GEV Terminal Sterilizers, making the
GEV a uniquely flexible sterilizer. Programs may include:
• Liquids in glass or plastic containers and open vessels
• Products in blister packs
• Textiles, glassware, utensils, filters, rubber stoppers
Excellent heat transfer
During heat up and sterilization and air are forcefully
recirculated throughout the products in the chamber by
one or more high-power fans. This provides excellent
heat transfer during the heating phase and uniform
temperature distribution during the sterilization phase.
Optimized cooling
Steam is condensed immediately after the sterilization
phase and replaced by sterile filtered air which is cooled
by internal heat exchangers fabricated from seamless
tubing. After cooling, the dry product may be unloaded
and moved immediately to the downstream process.
Rapid cooling and drying is achieved by powerful centrifugal
fans and internal water cooled heat exchangers.
The above dimensions are for models selected from a much wider range.
Models GEV 6610 and 6613 incorporate vertical sliding doors, whereas other models have horizontal sliding doors.
* Usable dimensions
GEV model 6610 6613 6913 6915 91413 91425 91637 91650
CHAMBER VOLUME m³ 0.5 0.6 1.0 1.2 2.3 4.3 7.6 10.1
*CHAMBER WIDTH, mm 600 660 900 950
*CHAMBER HEIGHT, mm 600 990 1450 1600
*CHAMBER DEPTH, mm 1000 1300 1350 1540 1350 2500 3750 5000
Sterile dry goods
ready for handling
Zone Control
This patented system allows the zones of a multi-rack
sterilizer to be independently controlled, allowing a single
process to be validated for either full or part batches.
This valuable feature is designed to save time during
validation while providing production managers with
flexibile equipment utilization (e.g. part load at the end of
the day).
12 | Getinge Terminal Sterilizers
Zone 1 Zone 2 Zone 3
Rapid, efficient sterilization
of bulk liquids
Using hot water recirculated by a high-capacity pump,
Getinge GEC Terminal Sterilizers provide efficient utilization
with high product throughput. Alternative cycles, such as
for porous textile loads, filled ampoules and dry empty
glassware, can also be incorporated in GEC models.
A closed system
The GEC sterilization process utilizes a closed loop
water system for rapid heating and cooling. Another
main benefit of using water as the heat transfer medium
is that the process sterilizes the water along with the
product and therefore presents no hazard to the pro-
duct. Any suitable type of water may be used, including
de-mineralized, distilled, purified or WFI. Selection of
appropriate process water is determined by the product
material and closure integrity, as well as a client’s
process requirements. As an option, water may be
stored in an integral sump for reuse.
External heat exchangers are used to indirectly cool
the circulating water after completion of the sterilization
phase.
Uniform temperature
Water cascades from a perforated tray at the top of the
chamber to create a uniform temperature. High water flow
rates also ensure that uniform temperature distribution is
maintained throughout the chamber during the sterilization
phase. Distortion or damage to flexible containers is
prevented by controlling filtered (through a bacteria-
retentive filter) air over-pressure during the process.
The closed system conserves heat and sterilizes the heating/
cooling water to minimize the risk of contamination.
The above dimensions are for models selected from a much wider range.
Models GEC 6610 and 6613 incorporate vertical sliding doors, whereas other models have horizontal sliding doors.
* Usable dimensions
GEC model 6610 6613 6913 6917 91413 91425 91837 131682
CHAMBER VOLUME m³ 0.5 0.6 0.8 1.1 1.8 3.3 6.4 20.0
CHAMBER WIDTH, mm 660 870 920 1270
CHAMBER HEIGHT, mm 600 850 1400 1750 1550
CHAMBER DEPTH, mm 1000 1300 1350 1700 1350 2500 3750 8200
Precise control of cooling
External heat exchangers are used to indirectly cool
the circulating water after completion of the sterilization
phase. Precise control of the cooling rate and the safe
handling temperature necessary for the product is easily
achieved using the GEC system (generally more rapidly
than the corresponding GEV or GE cycles).
Getinge Terminal Sterilizers | 13
14 | Getinge Terminal Sterilizers
complete logistic solutionS
COMPLIANT LOGISTICS
Compliant Logistics AB offer production logistics solutions for the
Medical Device  Pharmaceutical Industry; our solutions manage the
flow of materials, products and information through a production facility.
Compliant Logistics provide material management and assembly
systems solution based upon a modular hardware platform and an
integrated MES/SCADA software application. The system allows for
integration with other unit operation as well as vertically in the IT system,
eg ERP systems. The software optimizes production flow and manage
variants and has been developed and qualified according to GAMP.
www.compliantlogistics.com
Production Logistics. In a busy production
environment, transporting product to and from a
sterilization chamber is a logistical exercise.
Loads are often heavy (a rack of liquid product
can weigh more than 1000 kg) and are difficult and
potentially unsafe to handle manually.
Getinge recommends the use of automated load
handling systems for large loads and offer a variety
of alternatives to suit your product and installation
requirements.
Together with our global partner, Compliant Logistics,
we can provide conveyor systems that integrate with the
sterilizer and circulate the loading racks. These systems
designed to combine heavy industrial manipulation with
the GMP production environment.
Compliant Logistics can also provide robotic solutions
for automatic loading and unloading of shelves and
racks if required.
Rack Design
Protection of the product and process efficacy are
key to the rack design. Racks and shelves must allow
adequate and uniform flow of the sterilizing media, while
supporting the product to prevent deformation. Getinge
has experience of all types of packaging and can
recommend suitable shelving systems.
We also offer a test and prototyping service to assist in
the design of shelving and process development for new
packaging styles.
Regulatory compliance
The entire PACS 3500 is developed according to
stringent GAMP4 (Good Automated Manufacturing
Practice) guidelines of the pharmaceutical industry.
Every system is supported with comprehensive system
documentation.
Standard PLC Systems
The PACS 3500 is
designed for use with
sterile processing systems.
Many thousands of PACS
systems are in operation
around the world in vali-
dated production facilities.
However, if a customer prefers, standard PLC
systems are available based on Allen-Bradley or
Siemens hardware platforms. These PLCs can be
provided as standard options with similar functionality
and documentation to the Getinge PACS 3500.
Getinge control systems
Reproducibility of sterilization cycles is crucial in life
science applications. To achieve this and minimize
human error, Getinge supplies the PACS 3500 Control
System for use with its GEV/GEC Production Sterilizers.
PACS 3500 accurately handles tasks such as parameter
setting, sterilizer operations, system programming and
data processing, presentation and storage.
Versatile features
The major features included in PACS 3500 are:
• A user-friendly interface
• Extensive documentation
• Remaining cycle-time indicator
• Automatic sensor calibration
• Comprehensive alarms/alerts
• Process and alarm logging
• Multilevel password protection
• Multilanguage display
• PACS Supervisor independent monitoring system
Getinge Terminal Sterilizers | 15
Alternative control panels
OP30 user interface
• Door open/close buttons.
Status LEDs.
•	
5.7”color screen for process info:
	
– Remaining time, cycle  phase,
temperature(s)
• Graphical process presentation:
– Plot graph, bar graph
• Parameter settings.
• Maintenance  service menus.
• System configuration.
HMI’s use Getinge layout for operator
and technician familiarity.
S U
PPORT EQUIPM
E
N
T
T
R
A
I
N
I
N
G
TR A CE ABILITY
K
N
O
W
-
H
O
W
Getinge Infection Control
PO Box 69, SE-310 44 Getinge, Sweden
Phone: +46 35 15 55 00
Fax: +46 35 549 52
info@getinge.com www.getinge.com
THE GETINGE GROUP is a leading global provider of equipment
and systems that contribute to quality enhancement and cost
efficiency within healthcare and life sciences. Equipment, services
and technologies are supplied under the brands ARJO for patient
hygiene, patient handling and wound care, GETINGE for infection
control and prevention within healthcare and life science and
MAQUET for surgical workplaces, cardiopulmonary and critical care.
Getinge provides complete solutions for effective and
efficient cleaning, disinfection and sterilization in the
healthcare and life science sectors. Our know-how
comprises everything from architectural planning,
production and handling equipment, to systems for
full traceability of sterile goods. Our commitment
covers expert advice, training and long-term technical
support.
1745
ENG
07.06
·
Göteborgstryckeriet
·
We
reserve
the
right
to
make
technical
and
construction
changes.

More Related Content

Similar to Autoclaves-terminales-GEV-GEC.pdf

Sonix IV Industrial power GT-Series Ultrasonic Cleaning Systems
Sonix IV Industrial power GT-Series Ultrasonic Cleaning SystemsSonix IV Industrial power GT-Series Ultrasonic Cleaning Systems
Sonix IV Industrial power GT-Series Ultrasonic Cleaning Systems
Sonix IV Corporation
 
Triple walled vertical autoclave
Triple walled vertical autoclaveTriple walled vertical autoclave
Triple walled vertical autoclave
Acmas Technologies Pvt. Ltd.
 
BR-ASEPTIC-BARRIER-SYSTEMS-EN-1113
BR-ASEPTIC-BARRIER-SYSTEMS-EN-1113BR-ASEPTIC-BARRIER-SYSTEMS-EN-1113
BR-ASEPTIC-BARRIER-SYSTEMS-EN-1113
Simon Bailey
 
BR-ASEPTIC-BARRIER-SYSTEMS-EN-1113
BR-ASEPTIC-BARRIER-SYSTEMS-EN-1113BR-ASEPTIC-BARRIER-SYSTEMS-EN-1113
BR-ASEPTIC-BARRIER-SYSTEMS-EN-1113
Tony Rhodes
 
Rectangular horizontal autoclave
Rectangular horizontal autoclaveRectangular horizontal autoclave
Rectangular horizontal autoclave
Acmas Technologies Pvt. Ltd.
 
Benefits of cleaning
Benefits of cleaningBenefits of cleaning
Benefits of cleaning
Deep Clean Service
 
Flexim Fluxus Ultrasonic Flow Meters - Flow Measurement In Refineries - Broch...
Flexim Fluxus Ultrasonic Flow Meters - Flow Measurement In Refineries - Broch...Flexim Fluxus Ultrasonic Flow Meters - Flow Measurement In Refineries - Broch...
Flexim Fluxus Ultrasonic Flow Meters - Flow Measurement In Refineries - Broch...
Thorne & Derrick UK
 
GEV 2022 company presentation & application_ENG (1).pptx
GEV 2022 company presentation & application_ENG (1).pptxGEV 2022 company presentation & application_ENG (1).pptx
GEV 2022 company presentation & application_ENG (1).pptx
AhmedEZZAYTOUNI1
 
Flexible Aseptic Manufacturing
Flexible Aseptic ManufacturingFlexible Aseptic Manufacturing
Flexible Aseptic Manufacturing
Hargrove Life Sciences
 
Cement Autoclaves by ACMAS Technologies Pvt Ltd.
Cement Autoclaves by ACMAS Technologies Pvt Ltd.Cement Autoclaves by ACMAS Technologies Pvt Ltd.
Cement Autoclaves by ACMAS Technologies Pvt Ltd.
Acmas Technologies Pvt. Ltd.
 
Hemiwedge Cartridge Valve
Hemiwedge Cartridge ValveHemiwedge Cartridge Valve
Hemiwedge Cartridge Valve
Adroitt Flow Control Pvt Ltd
 
GTC's High Performance Tray Tower Solutions
GTC's High Performance Tray Tower SolutionsGTC's High Performance Tray Tower Solutions
GTC's High Performance Tray Tower Solutions
GTC Technology
 
Twin Process Filtration - Brochure Horizontal Plate Filter (HPF) with scavenger
Twin Process Filtration - Brochure Horizontal Plate Filter (HPF) with scavengerTwin Process Filtration - Brochure Horizontal Plate Filter (HPF) with scavenger
Twin Process Filtration - Brochure Horizontal Plate Filter (HPF) with scavenger
Roy Niekerk
 
VEGA The Yellow World Of Pressure Measurement - Technology Brochure
VEGA The Yellow World Of Pressure Measurement - Technology BrochureVEGA The Yellow World Of Pressure Measurement - Technology Brochure
VEGA The Yellow World Of Pressure Measurement - Technology Brochure
Thorne & Derrick UK
 
Biodiesel Biofuel Producer Processing Plant
Biodiesel Biofuel Producer Processing PlantBiodiesel Biofuel Producer Processing Plant
Biodiesel Biofuel Producer Processing Plant
vgarlington
 
Telstar Pura STI Brochure
Telstar Pura STI BrochureTelstar Pura STI Brochure
Telstar Pura STI Brochure
Tony Rhodes
 
Telstar Pura STI Brochure
Telstar Pura STI BrochureTelstar Pura STI Brochure
Telstar Pura STI Brochure
Simon Bailey
 
Telstar Pura STI Brochure
Telstar Pura STI BrochureTelstar Pura STI Brochure
Telstar Pura STI Brochure
Kathryn Jepson
 
Aloevera processing line - Equipment for Aloe Vera Plant
Aloevera processing line - Equipment for Aloe Vera PlantAloevera processing line - Equipment for Aloe Vera Plant
Aloevera processing line - Equipment for Aloe Vera Plant
GfK
 
CR_Furnace_Tube_and_Pipeline_Pigging
CR_Furnace_Tube_and_Pipeline_PiggingCR_Furnace_Tube_and_Pipeline_Pigging
CR_Furnace_Tube_and_Pipeline_Pigging
Paul Francis
 

Similar to Autoclaves-terminales-GEV-GEC.pdf (20)

Sonix IV Industrial power GT-Series Ultrasonic Cleaning Systems
Sonix IV Industrial power GT-Series Ultrasonic Cleaning SystemsSonix IV Industrial power GT-Series Ultrasonic Cleaning Systems
Sonix IV Industrial power GT-Series Ultrasonic Cleaning Systems
 
Triple walled vertical autoclave
Triple walled vertical autoclaveTriple walled vertical autoclave
Triple walled vertical autoclave
 
BR-ASEPTIC-BARRIER-SYSTEMS-EN-1113
BR-ASEPTIC-BARRIER-SYSTEMS-EN-1113BR-ASEPTIC-BARRIER-SYSTEMS-EN-1113
BR-ASEPTIC-BARRIER-SYSTEMS-EN-1113
 
BR-ASEPTIC-BARRIER-SYSTEMS-EN-1113
BR-ASEPTIC-BARRIER-SYSTEMS-EN-1113BR-ASEPTIC-BARRIER-SYSTEMS-EN-1113
BR-ASEPTIC-BARRIER-SYSTEMS-EN-1113
 
Rectangular horizontal autoclave
Rectangular horizontal autoclaveRectangular horizontal autoclave
Rectangular horizontal autoclave
 
Benefits of cleaning
Benefits of cleaningBenefits of cleaning
Benefits of cleaning
 
Flexim Fluxus Ultrasonic Flow Meters - Flow Measurement In Refineries - Broch...
Flexim Fluxus Ultrasonic Flow Meters - Flow Measurement In Refineries - Broch...Flexim Fluxus Ultrasonic Flow Meters - Flow Measurement In Refineries - Broch...
Flexim Fluxus Ultrasonic Flow Meters - Flow Measurement In Refineries - Broch...
 
GEV 2022 company presentation & application_ENG (1).pptx
GEV 2022 company presentation & application_ENG (1).pptxGEV 2022 company presentation & application_ENG (1).pptx
GEV 2022 company presentation & application_ENG (1).pptx
 
Flexible Aseptic Manufacturing
Flexible Aseptic ManufacturingFlexible Aseptic Manufacturing
Flexible Aseptic Manufacturing
 
Cement Autoclaves by ACMAS Technologies Pvt Ltd.
Cement Autoclaves by ACMAS Technologies Pvt Ltd.Cement Autoclaves by ACMAS Technologies Pvt Ltd.
Cement Autoclaves by ACMAS Technologies Pvt Ltd.
 
Hemiwedge Cartridge Valve
Hemiwedge Cartridge ValveHemiwedge Cartridge Valve
Hemiwedge Cartridge Valve
 
GTC's High Performance Tray Tower Solutions
GTC's High Performance Tray Tower SolutionsGTC's High Performance Tray Tower Solutions
GTC's High Performance Tray Tower Solutions
 
Twin Process Filtration - Brochure Horizontal Plate Filter (HPF) with scavenger
Twin Process Filtration - Brochure Horizontal Plate Filter (HPF) with scavengerTwin Process Filtration - Brochure Horizontal Plate Filter (HPF) with scavenger
Twin Process Filtration - Brochure Horizontal Plate Filter (HPF) with scavenger
 
VEGA The Yellow World Of Pressure Measurement - Technology Brochure
VEGA The Yellow World Of Pressure Measurement - Technology BrochureVEGA The Yellow World Of Pressure Measurement - Technology Brochure
VEGA The Yellow World Of Pressure Measurement - Technology Brochure
 
Biodiesel Biofuel Producer Processing Plant
Biodiesel Biofuel Producer Processing PlantBiodiesel Biofuel Producer Processing Plant
Biodiesel Biofuel Producer Processing Plant
 
Telstar Pura STI Brochure
Telstar Pura STI BrochureTelstar Pura STI Brochure
Telstar Pura STI Brochure
 
Telstar Pura STI Brochure
Telstar Pura STI BrochureTelstar Pura STI Brochure
Telstar Pura STI Brochure
 
Telstar Pura STI Brochure
Telstar Pura STI BrochureTelstar Pura STI Brochure
Telstar Pura STI Brochure
 
Aloevera processing line - Equipment for Aloe Vera Plant
Aloevera processing line - Equipment for Aloe Vera PlantAloevera processing line - Equipment for Aloe Vera Plant
Aloevera processing line - Equipment for Aloe Vera Plant
 
CR_Furnace_Tube_and_Pipeline_Pigging
CR_Furnace_Tube_and_Pipeline_PiggingCR_Furnace_Tube_and_Pipeline_Pigging
CR_Furnace_Tube_and_Pipeline_Pigging
 

Recently uploaded

Low power architecture of logic gates using adiabatic techniques
Low power architecture of logic gates using adiabatic techniquesLow power architecture of logic gates using adiabatic techniques
Low power architecture of logic gates using adiabatic techniques
nooriasukmaningtyas
 
Heat Resistant Concrete Presentation ppt
Heat Resistant Concrete Presentation pptHeat Resistant Concrete Presentation ppt
Heat Resistant Concrete Presentation ppt
mamunhossenbd75
 
Swimming pool mechanical components design.pptx
Swimming pool  mechanical components design.pptxSwimming pool  mechanical components design.pptx
Swimming pool mechanical components design.pptx
yokeleetan1
 
Properties Railway Sleepers and Test.pptx
Properties Railway Sleepers and Test.pptxProperties Railway Sleepers and Test.pptx
Properties Railway Sleepers and Test.pptx
MDSABBIROJJAMANPAYEL
 
Exception Handling notes in java exception
Exception Handling notes in java exceptionException Handling notes in java exception
Exception Handling notes in java exception
Ratnakar Mikkili
 
Series of visio cisco devices Cisco_Icons.ppt
Series of visio cisco devices Cisco_Icons.pptSeries of visio cisco devices Cisco_Icons.ppt
Series of visio cisco devices Cisco_Icons.ppt
PauloRodrigues104553
 
IEEE Aerospace and Electronic Systems Society as a Graduate Student Member
IEEE Aerospace and Electronic Systems Society as a Graduate Student MemberIEEE Aerospace and Electronic Systems Society as a Graduate Student Member
IEEE Aerospace and Electronic Systems Society as a Graduate Student Member
VICTOR MAESTRE RAMIREZ
 
digital fundamental by Thomas L.floydl.pdf
digital fundamental by Thomas L.floydl.pdfdigital fundamental by Thomas L.floydl.pdf
digital fundamental by Thomas L.floydl.pdf
drwaing
 
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressionsKuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
Victor Morales
 
Advanced control scheme of doubly fed induction generator for wind turbine us...
Advanced control scheme of doubly fed induction generator for wind turbine us...Advanced control scheme of doubly fed induction generator for wind turbine us...
Advanced control scheme of doubly fed induction generator for wind turbine us...
IJECEIAES
 
Modelagem de um CSTR com reação endotermica.pdf
Modelagem de um CSTR com reação endotermica.pdfModelagem de um CSTR com reação endotermica.pdf
Modelagem de um CSTR com reação endotermica.pdf
camseq
 
sieving analysis and results interpretation
sieving analysis and results interpretationsieving analysis and results interpretation
sieving analysis and results interpretation
ssuser36d3051
 
6th International Conference on Machine Learning & Applications (CMLA 2024)
6th International Conference on Machine Learning & Applications (CMLA 2024)6th International Conference on Machine Learning & Applications (CMLA 2024)
6th International Conference on Machine Learning & Applications (CMLA 2024)
ClaraZara1
 
A SYSTEMATIC RISK ASSESSMENT APPROACH FOR SECURING THE SMART IRRIGATION SYSTEMS
A SYSTEMATIC RISK ASSESSMENT APPROACH FOR SECURING THE SMART IRRIGATION SYSTEMSA SYSTEMATIC RISK ASSESSMENT APPROACH FOR SECURING THE SMART IRRIGATION SYSTEMS
A SYSTEMATIC RISK ASSESSMENT APPROACH FOR SECURING THE SMART IRRIGATION SYSTEMS
IJNSA Journal
 
CSM Cloud Service Management Presentarion
CSM Cloud Service Management PresentarionCSM Cloud Service Management Presentarion
CSM Cloud Service Management Presentarion
rpskprasana
 
PPT on GRP pipes manufacturing and testing
PPT on GRP pipes manufacturing and testingPPT on GRP pipes manufacturing and testing
PPT on GRP pipes manufacturing and testing
anoopmanoharan2
 
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
insn4465
 
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
ihlasbinance2003
 
basic-wireline-operations-course-mahmoud-f-radwan.pdf
basic-wireline-operations-course-mahmoud-f-radwan.pdfbasic-wireline-operations-course-mahmoud-f-radwan.pdf
basic-wireline-operations-course-mahmoud-f-radwan.pdf
NidhalKahouli2
 
2. Operations Strategy in a Global Environment.ppt
2. Operations Strategy in a Global Environment.ppt2. Operations Strategy in a Global Environment.ppt
2. Operations Strategy in a Global Environment.ppt
PuktoonEngr
 

Recently uploaded (20)

Low power architecture of logic gates using adiabatic techniques
Low power architecture of logic gates using adiabatic techniquesLow power architecture of logic gates using adiabatic techniques
Low power architecture of logic gates using adiabatic techniques
 
Heat Resistant Concrete Presentation ppt
Heat Resistant Concrete Presentation pptHeat Resistant Concrete Presentation ppt
Heat Resistant Concrete Presentation ppt
 
Swimming pool mechanical components design.pptx
Swimming pool  mechanical components design.pptxSwimming pool  mechanical components design.pptx
Swimming pool mechanical components design.pptx
 
Properties Railway Sleepers and Test.pptx
Properties Railway Sleepers and Test.pptxProperties Railway Sleepers and Test.pptx
Properties Railway Sleepers and Test.pptx
 
Exception Handling notes in java exception
Exception Handling notes in java exceptionException Handling notes in java exception
Exception Handling notes in java exception
 
Series of visio cisco devices Cisco_Icons.ppt
Series of visio cisco devices Cisco_Icons.pptSeries of visio cisco devices Cisco_Icons.ppt
Series of visio cisco devices Cisco_Icons.ppt
 
IEEE Aerospace and Electronic Systems Society as a Graduate Student Member
IEEE Aerospace and Electronic Systems Society as a Graduate Student MemberIEEE Aerospace and Electronic Systems Society as a Graduate Student Member
IEEE Aerospace and Electronic Systems Society as a Graduate Student Member
 
digital fundamental by Thomas L.floydl.pdf
digital fundamental by Thomas L.floydl.pdfdigital fundamental by Thomas L.floydl.pdf
digital fundamental by Thomas L.floydl.pdf
 
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressionsKuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
 
Advanced control scheme of doubly fed induction generator for wind turbine us...
Advanced control scheme of doubly fed induction generator for wind turbine us...Advanced control scheme of doubly fed induction generator for wind turbine us...
Advanced control scheme of doubly fed induction generator for wind turbine us...
 
Modelagem de um CSTR com reação endotermica.pdf
Modelagem de um CSTR com reação endotermica.pdfModelagem de um CSTR com reação endotermica.pdf
Modelagem de um CSTR com reação endotermica.pdf
 
sieving analysis and results interpretation
sieving analysis and results interpretationsieving analysis and results interpretation
sieving analysis and results interpretation
 
6th International Conference on Machine Learning & Applications (CMLA 2024)
6th International Conference on Machine Learning & Applications (CMLA 2024)6th International Conference on Machine Learning & Applications (CMLA 2024)
6th International Conference on Machine Learning & Applications (CMLA 2024)
 
A SYSTEMATIC RISK ASSESSMENT APPROACH FOR SECURING THE SMART IRRIGATION SYSTEMS
A SYSTEMATIC RISK ASSESSMENT APPROACH FOR SECURING THE SMART IRRIGATION SYSTEMSA SYSTEMATIC RISK ASSESSMENT APPROACH FOR SECURING THE SMART IRRIGATION SYSTEMS
A SYSTEMATIC RISK ASSESSMENT APPROACH FOR SECURING THE SMART IRRIGATION SYSTEMS
 
CSM Cloud Service Management Presentarion
CSM Cloud Service Management PresentarionCSM Cloud Service Management Presentarion
CSM Cloud Service Management Presentarion
 
PPT on GRP pipes manufacturing and testing
PPT on GRP pipes manufacturing and testingPPT on GRP pipes manufacturing and testing
PPT on GRP pipes manufacturing and testing
 
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
 
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
 
basic-wireline-operations-course-mahmoud-f-radwan.pdf
basic-wireline-operations-course-mahmoud-f-radwan.pdfbasic-wireline-operations-course-mahmoud-f-radwan.pdf
basic-wireline-operations-course-mahmoud-f-radwan.pdf
 
2. Operations Strategy in a Global Environment.ppt
2. Operations Strategy in a Global Environment.ppt2. Operations Strategy in a Global Environment.ppt
2. Operations Strategy in a Global Environment.ppt
 

Autoclaves-terminales-GEV-GEC.pdf

  • 1. Getinge Terminal Sterilizers Securing optimal processing of packaged pharmaceuticals
  • 2.
  • 3. Getinge Terminal Sterilizers | From concept to compliance As a world leader in the field of washing and sterilization, Getinge draws from over 100 years of accumulated knowledge to provide the advanced equipment, application skills, documentation, regulatory know-how and support services you can depend on from “concept to compliance”. Pharmaceutical competence Our long-term involvement with washing and sterilization procedures has made us intimately familiar with pharmaceutical production methods. Therefore we are well aware of the challenges associated with the sterile treatment of liquids, solids and the numerous types of delivery systems available today. The complete production chain Getinge can take care of virtually all your needs in the sterile processing of pharmaceuticals. We supply: • Water pretreatment systems • Water distillation systems • Steam generators • Component and equipment washers • Component and equipment sterilizers • Closure processing systems • Terminal sterilizers • Isolators for sterility testing and processing • Installation design support services • Testing, commissioning and qualification (FAT/SAT, IQ/OQ) • Training and after-sales support Optimizing economy As Getinge supplies virtually everything from concept to compliance, we can optimize the lifecycle economy for your sterile processing equipment. Dealing with just one competent company will save you time, effort and costs. Since all our equipment is compatible and has common documentation, rapid system integration and installation are assured. And equipment that is built to meet the world’s highest standards of quality and safety means maximal uptime and a safer working environment. Pharmaceutical production puts stringent demands on sterile processing equipment in terms of maximal uptime, high performance and optimal production capacity. And, of course, proper safeguards that exceed industry standard practice should minimize microbial and particulate contamination.
  • 4. | Getinge Terminal Sterilizers Gentle but effective product sterilization Getinge develops, manufactures and supplies completely integrated washing and sterilization systems for use within the life sciences. GEV/GEC sterilization kills the toughest microbes but is gentle enough to protect the integrity of components, products and packaging. A wide range of sterilization cycles increases their application versatility. Getinge GE Steam Sterilizers can also be used to sterilize products in ampoules or vials. RECEPTION UTILITIES DISTRIBUTION BARRIER
  • 5. A B Getinge Ventilator Terminal Sterilizers (GEVs)* are designed primarily for sterilizing products that must be dry and ready for further handling immediately after the cooling phase. Standard chamber volume: 0.5 to 10.1 m³. * GEV Terminal Sterilizers use steam/air mixtures for sterilization. Getinge Circulating Water Terminal Sterilizers (GECs) are primarily intended for sterilizing large volumes of liquids in sealed glass or plastic containers. Standard chamber volume: 0.5 to 20.0 m³. STERILE ZONE CLEAN ZONE BARRIER BARRIER A GEV B GEC Pharmaceutical production Getinge Terminal Sterilizers |
  • 6. Safeguarding your investment Robotic welding is used wherever possible to provide a high level of consistency and accuracy. A sterilization system represents a large capital investment. Therefore Getinge takes measures to ensure that our GEV/GEC Terminal Sterilizers provide true value with regard to design, performance and lifecycle economy. Strong on safety Getinge sterilizers are designed and built to meet the world’s highest standards of quality and safety. Produc­tion facilities are ISO 9001-certified and all appropriate inter­ na­­tional regulations for safety, pressure vessels and the environment are rigorously followed. A risk assess­ment is performed on all products, focusing on personnel safety. Leading-edge construction The production of Getinge sterilizers involves leading-edge construction techniques and use of the highest-grade materials. Accurate laser cutting minimizes the number of construction welds. Robotic welding provides a level of weld consistency superior to manual techniques and elimi­ nates defects in welded seams. Robotic grinding systems reduce sites of potential corrosion and allow easy cleaning. And the unique sectional jacket design provides rigidity, allows visual inspection of all welds and reduces weight. Advantages of sliding doors The sliding doors of GEV/GEC Terminal Sterilizers offer a number of advantages over hinged doors. They are cleaner, safer and simpler. Hinges require grease which can collect dirt. Sliding doors are safe since the hot inner surface is not exposed when the door is open. Space is maximized as the door does not swing outward, and there is free access to the chamber for loading/unloading. Widest range of chamber sizes Getinge has the widest range of chamber sizes available from any manufacturer to meet the needs of all common applications. Standard chamber sizes range from 0.5 to 20 m3 . Customized chamber sizes are available on request. Regulatory issues Getinge closely follows industry trends, practices, guidelines and regulatory requirements. Additionally we actively participate in working groups and committees working to refine these requirements. GAMP | cGMP | BPE2005 | MCA | ISPE BASELINE GUIDES FDA | EN46002 | ISO9000 | 21CFR Part 11 All sterilizers are manufactured according to the guide- lines or standards relating to the intended applications and the country of installation. Protecting the environment Special processes have been developed for safe disposal of discarded waste for environmental protection. Options are also available to reduce cooling water consumption by up to 75%. Getinge sterilizers are built in state-of-the-art production facilities. | Getinge Terminal Sterilizers
  • 7. Infection Control | 1. Batteries of dense heat exchangers fabricated from seamless stainless- steel tubing power the GEV’s rapid cooling. GMP compliant with no connections inside the chamber. 2. Sectional internal liners control GEV airflow and consequently temperature distribution. Each zone is equipped with fan, heat exchanger and piping. 3. A custom designed stainless steel centrifugal fan delivers high GEV airflow rates. Driven via a unique mechanical seal by an electric motor. 4. Unique distribution plate of the GEC ensures constant and uniform water cascade over the product for uniform heating and cooling. 5. A powerful sanitary centrifugal pump delivers massive flow rates to the GEC cascade system. Efficient plate heat exchangers heat and cool the circulating water. 6. The doors of Getinge sterilizers are the cleanest, safest and simplest on the market. 7. The unique sectional jacket adds strength and rigidity to the chamber, and robotic welding eliminates defects. The resulting construction ensures a long product lifecycle to safeguard your capital investment. 8. T op-quality piping and components are assembled to the highest standards. 1 8 2 3 4 5 6 7
  • 8. Features that satisfy your processing needs Versatile programs Program combinations are designed to suit particular applications of GEV or GEC models, whether for sterilizing different types of product or performing single- product sterilization cycles. Sterilizers that incorporate a vacuum pump provide even more versatile operation. With GEV models, the products in the chamber may be heated with hot air at the start of a cycle before steam is used in order to minimize condensation and shorten the drying phase. The patented GEV “Zone Control™” feature allows validated processing of part batches, allowing production flexibility while reducing validation effort. With GEC models, temperature overdrive is used at the start of a cycle to shorten both the heating phase and the total process cycle. Numerous design options Just a few design options that reflect Getinge’s reputation as a flexible and innovative supplier are: • A wide range of chamber capacities. • Single-door or double-door, pass-through models. • Dual sequencing controls at both ends of a pass- through model with master control panels if required. • Service area on either side of the chamber. • Clean steam supply from a built-in generator and/or external source. • Sterilizer mounted in either a cabinet, recessed be- tween two walls, or recessed in a cabinet within one wall. • A range of loading systems, e.g. powered roller conveyors, trolleys, pallet trucks and the Getinge RAT system. • Models that can be installed directly on a floor for loading with racks and transfer trolleys, or pit-mounted models for convenient roll-in, roll-out load handling. Complete loading/unloading solutions Getinge’s extensive choice of high-grade stainless steel loading systems range from basic product handling items such as sliding shelves to highly automated loading/ unloading units. These are ergonomically designed for safe, simple and smooth product handling. Both standard and custom-built systems are provided to meet the demands of diverse material-handling challenges. The wide variety of loading/unloading equipment includes: • Shelf racks and trays • Stackable shelves • Various rail systems • Loading trolleys • Roller conveyors Handling and movement of heavy production loads can be difficult and hazardous. Getinge can provide complete production logistics systems, assisted by our specialist partner, Compliant Logistics. See page 14 for more details. GEV processing results in dry cool products. It suits containers with closures not mechanically held in place and blister packs. The features built into Getinge GEV/GEC Terminal Sterilizers allow the user to define and program the processing parameters best suited to particular types of packaged pharmaceuticals. Steam/air mixtures in the GEV Terminal Sterilizer are used to sterilize products that need to be dry after the cooling cycle, whereas cascading water in the GEC Terminal Sterilizer is used for the rapid sterilization of bulk liquids. | Getinge Terminal Sterilizers
  • 9.
  • 10. In keeping with Getinge’s policy of continuous product and application development, a Sterilization Technology Center is available for customers who need to define the correct processing conditions for particular products. Sterilization Technology Centers are located in Japan, Sweden, the USA and the UK. Each center is equipped with specially designed sterilizers that allow programming of a wide range of process cycles and printout of relevant documentation. Conduct your own test runs The Sterilization Technology Center is the place to come and discuss your application challenges with our experienced personnel. You can conduct test runs on your own products and packaging to define the sterilization parameters best suited to them. Scale-up runs can also be carried out to test the suitability of selected cycles prior to final decision-making. Customer programming via the control system interface also makes it possible for you to make changes to each phase of the process cycle after a sterilizer has been installed in your production facilities. Preventing deformation GEC Sterilizers provide two ways of preventing deformation of plastic containers: the use of air overpressure, independently controlled during the heating and cooling phases, and, when required, the use of special loading trays developed by Getinge. GEV Terminal Sterilizers are gentler on products and Enabling you to achieve optimal processing GEC processing enables high-volume throughput of bulk liquids and does not deform flexible plastic containers. 10 | Getinge Terminal Sterilizers
  • 11. Partial pressures of air and steam add up to the total pressure in a sealed container. One can adjust the heating and cooling rates to optimize the process cycle for the best production economy/utility consumption. Steam Air Total pressure Bar abs. 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 ˚C 40 60 80 100 120 140 20 10 20 30 40 50 60 min. 1.5 2.0 2.5 3.0 3.5 4.0 Bar abs. 20 40 60 80 100 120 Chamber temp. Load temp. Chamber press °C packaging that tend to be pressure-sensitive. Air overpressure is used during the heating and cooling phases, but only to prevent plastic containers from deforming or closures from being displaced. The GEV sterilizer incorporates programs that ensure PVC containers are clear at the end of the cooling cycle. Accurate pressure-temperature link The liquid being sterilized, fill volume, container material style, and the type of closure all determine the correct temperature and pressure to be used during the process cycle. These parameters are independently controlled in GEV/GEC units so it is easier to achieve the required processing conditions. Furthermore, excellent pressure control is provided by accurately linking any change in pressure closely to product temperature throughout the complete process cycle. A combination of good heat transfer and optimized cooling for different packaging offered by GEV/GEC Terminal Sterilizers enables rapid processing to be defined for a wide range of products. Own design team We have our own team of design and planning experts that creates installation drawings for individual machines as well for complete washing and sterilization systems, along with utilities that match process and production needs. So once you have chosen the sterilizer or system that satisfies your production needs, we can help you to get it up and running as soon as possible. Getinge Terminal Sterilizers | 11
  • 12. Dry products from Getinge GEV Terminal Sterilizers are ready for immediate handling and further processing such as such as inspection, labeling, packing, etc. GEV Product Sterilizers are also ideal for products, e.g. blister-packed products and sophisticated delivery devices, that can be distorted or damaged by standard steam processes. Moisture-sensitive materials also benefit from GEV process and the variable and independent regulation of air overpressure makes it possible to design sterilization programs for a range of pressure-sensitive products. Alternative cycles, including vacuum cycles can also be incorporated in GEV Terminal Sterilizers, making the GEV a uniquely flexible sterilizer. Programs may include: • Liquids in glass or plastic containers and open vessels • Products in blister packs • Textiles, glassware, utensils, filters, rubber stoppers Excellent heat transfer During heat up and sterilization and air are forcefully recirculated throughout the products in the chamber by one or more high-power fans. This provides excellent heat transfer during the heating phase and uniform temperature distribution during the sterilization phase. Optimized cooling Steam is condensed immediately after the sterilization phase and replaced by sterile filtered air which is cooled by internal heat exchangers fabricated from seamless tubing. After cooling, the dry product may be unloaded and moved immediately to the downstream process. Rapid cooling and drying is achieved by powerful centrifugal fans and internal water cooled heat exchangers. The above dimensions are for models selected from a much wider range. Models GEV 6610 and 6613 incorporate vertical sliding doors, whereas other models have horizontal sliding doors. * Usable dimensions GEV model 6610 6613 6913 6915 91413 91425 91637 91650 CHAMBER VOLUME m³ 0.5 0.6 1.0 1.2 2.3 4.3 7.6 10.1 *CHAMBER WIDTH, mm 600 660 900 950 *CHAMBER HEIGHT, mm 600 990 1450 1600 *CHAMBER DEPTH, mm 1000 1300 1350 1540 1350 2500 3750 5000 Sterile dry goods ready for handling Zone Control This patented system allows the zones of a multi-rack sterilizer to be independently controlled, allowing a single process to be validated for either full or part batches. This valuable feature is designed to save time during validation while providing production managers with flexibile equipment utilization (e.g. part load at the end of the day). 12 | Getinge Terminal Sterilizers Zone 1 Zone 2 Zone 3
  • 13. Rapid, efficient sterilization of bulk liquids Using hot water recirculated by a high-capacity pump, Getinge GEC Terminal Sterilizers provide efficient utilization with high product throughput. Alternative cycles, such as for porous textile loads, filled ampoules and dry empty glassware, can also be incorporated in GEC models. A closed system The GEC sterilization process utilizes a closed loop water system for rapid heating and cooling. Another main benefit of using water as the heat transfer medium is that the process sterilizes the water along with the product and therefore presents no hazard to the pro- duct. Any suitable type of water may be used, including de-mineralized, distilled, purified or WFI. Selection of appropriate process water is determined by the product material and closure integrity, as well as a client’s process requirements. As an option, water may be stored in an integral sump for reuse. External heat exchangers are used to indirectly cool the circulating water after completion of the sterilization phase. Uniform temperature Water cascades from a perforated tray at the top of the chamber to create a uniform temperature. High water flow rates also ensure that uniform temperature distribution is maintained throughout the chamber during the sterilization phase. Distortion or damage to flexible containers is prevented by controlling filtered (through a bacteria- retentive filter) air over-pressure during the process. The closed system conserves heat and sterilizes the heating/ cooling water to minimize the risk of contamination. The above dimensions are for models selected from a much wider range. Models GEC 6610 and 6613 incorporate vertical sliding doors, whereas other models have horizontal sliding doors. * Usable dimensions GEC model 6610 6613 6913 6917 91413 91425 91837 131682 CHAMBER VOLUME m³ 0.5 0.6 0.8 1.1 1.8 3.3 6.4 20.0 CHAMBER WIDTH, mm 660 870 920 1270 CHAMBER HEIGHT, mm 600 850 1400 1750 1550 CHAMBER DEPTH, mm 1000 1300 1350 1700 1350 2500 3750 8200 Precise control of cooling External heat exchangers are used to indirectly cool the circulating water after completion of the sterilization phase. Precise control of the cooling rate and the safe handling temperature necessary for the product is easily achieved using the GEC system (generally more rapidly than the corresponding GEV or GE cycles). Getinge Terminal Sterilizers | 13
  • 14. 14 | Getinge Terminal Sterilizers complete logistic solutionS COMPLIANT LOGISTICS Compliant Logistics AB offer production logistics solutions for the Medical Device Pharmaceutical Industry; our solutions manage the flow of materials, products and information through a production facility. Compliant Logistics provide material management and assembly systems solution based upon a modular hardware platform and an integrated MES/SCADA software application. The system allows for integration with other unit operation as well as vertically in the IT system, eg ERP systems. The software optimizes production flow and manage variants and has been developed and qualified according to GAMP. www.compliantlogistics.com Production Logistics. In a busy production environment, transporting product to and from a sterilization chamber is a logistical exercise. Loads are often heavy (a rack of liquid product can weigh more than 1000 kg) and are difficult and potentially unsafe to handle manually. Getinge recommends the use of automated load handling systems for large loads and offer a variety of alternatives to suit your product and installation requirements. Together with our global partner, Compliant Logistics, we can provide conveyor systems that integrate with the sterilizer and circulate the loading racks. These systems designed to combine heavy industrial manipulation with the GMP production environment. Compliant Logistics can also provide robotic solutions for automatic loading and unloading of shelves and racks if required. Rack Design Protection of the product and process efficacy are key to the rack design. Racks and shelves must allow adequate and uniform flow of the sterilizing media, while supporting the product to prevent deformation. Getinge has experience of all types of packaging and can recommend suitable shelving systems. We also offer a test and prototyping service to assist in the design of shelving and process development for new packaging styles.
  • 15. Regulatory compliance The entire PACS 3500 is developed according to stringent GAMP4 (Good Automated Manufacturing Practice) guidelines of the pharmaceutical industry. Every system is supported with comprehensive system documentation. Standard PLC Systems The PACS 3500 is designed for use with sterile processing systems. Many thousands of PACS systems are in operation around the world in vali- dated production facilities. However, if a customer prefers, standard PLC systems are available based on Allen-Bradley or Siemens hardware platforms. These PLCs can be provided as standard options with similar functionality and documentation to the Getinge PACS 3500. Getinge control systems Reproducibility of sterilization cycles is crucial in life science applications. To achieve this and minimize human error, Getinge supplies the PACS 3500 Control System for use with its GEV/GEC Production Sterilizers. PACS 3500 accurately handles tasks such as parameter setting, sterilizer operations, system programming and data processing, presentation and storage. Versatile features The major features included in PACS 3500 are: • A user-friendly interface • Extensive documentation • Remaining cycle-time indicator • Automatic sensor calibration • Comprehensive alarms/alerts • Process and alarm logging • Multilevel password protection • Multilanguage display • PACS Supervisor independent monitoring system Getinge Terminal Sterilizers | 15 Alternative control panels OP30 user interface • Door open/close buttons. Status LEDs. • 5.7”color screen for process info: – Remaining time, cycle phase, temperature(s) • Graphical process presentation: – Plot graph, bar graph • Parameter settings. • Maintenance service menus. • System configuration. HMI’s use Getinge layout for operator and technician familiarity.
  • 16. S U PPORT EQUIPM E N T T R A I N I N G TR A CE ABILITY K N O W - H O W Getinge Infection Control PO Box 69, SE-310 44 Getinge, Sweden Phone: +46 35 15 55 00 Fax: +46 35 549 52 info@getinge.com www.getinge.com THE GETINGE GROUP is a leading global provider of equipment and systems that contribute to quality enhancement and cost efficiency within healthcare and life sciences. Equipment, services and technologies are supplied under the brands ARJO for patient hygiene, patient handling and wound care, GETINGE for infection control and prevention within healthcare and life science and MAQUET for surgical workplaces, cardiopulmonary and critical care. Getinge provides complete solutions for effective and efficient cleaning, disinfection and sterilization in the healthcare and life science sectors. Our know-how comprises everything from architectural planning, production and handling equipment, to systems for full traceability of sterile goods. Our commitment covers expert advice, training and long-term technical support. 1745 ENG 07.06 · Göteborgstryckeriet · We reserve the right to make technical and construction changes.