Arterial cannula
Straight Tip Reinforced
Wirewound Arterial Cannula
with Ce
• Cannula feaures
*stainless steel wirewound
cannula body which is flexbile
and kin-resistant;
*thin wall and tapered
construction maximizes flow
rates;
*with tip orientation line
permits precise insterting;
*with vented or non-vented
connector;
*straight or curved tip, with
fixed or adjusted ring
*used during open heat surgery
to build extracorporeal circuit
CE 0197 Sucker for Heart Surgery
• Application
It is used for attracting
blood in the operating
area in cardiac
operation to ensure a
clear vision.
CE 0197 Vents for Open Heart Surgery
• Application
In cardiac operation, it
is used for attracting
the blood in left atrium
through a trial sepal or
upper lung vein,
inserting in left atrium.
Antegrade/Aortic
Root/Perfusion/Cardioplegia Cannula
• Application
In cardiac operation, the
perfusion cannula is inserted into
root of aorta which cold arrest
liquid perfused.
Features
1. Proprietary center vented
needle helps control blood flow
while venting;
2. Designed with a soft tip to be
atraumatic to the aorta;
3. It is flexible and convenient in
inserting;
4. Antigrade perfusion
5. Variety of cardioplegia delivery
options for today's challenging
patients.
Coronary Artery Ostial Cannula with
CE Approved
• Features
1. Antegrade;
2. Coronary artery ostial
cannula;
3. Basket tip with high-
flow
4. 90° & 45°
Aortic Root Cannula with Ventline
• Application: In cardiac
operation, the perfusion
cannula is inserted into root of
aorta which cold arrest liquid
perfused.
Features:
1. Proprietary center vented
needle helps control blood
flow while venting;
2. Designed with a soft tip to
be atraumatic to the aorta;
3. It is flexible and convenient
in inserting;
4. With ventline;
5. Antegrade perfusion;
PVC/Disposable/Stopcock/Aortic
Root Cannula
• Application
In cardiac operation, the
perfusion cannula is inserted into
root of aorta which cold arrest
liquid perfused.
Features
1. Proprietary center vented
needle helps control blood flow
while venting;
2. Designed with a soft tip to be
atraumatic to the aorta;
3. It is flexible and convenient in
inserting;
4. Straight type with high-flow
stopcock
5. Antigrade perfusion
Single Stage Venous Cannula with Ce
• Application
In cardiac operation under
direct vision, it can be
inserted into the vein for
blood flow in extracorporeal
circulation.
1. Kink resists wire-wound
reinforced body
2. Fflexible body enables
easy positioning;
3. Thin wall construction
maximizes flow rates

Arterial cannula

  • 1.
  • 2.
    Straight Tip Reinforced WirewoundArterial Cannula with Ce • Cannula feaures *stainless steel wirewound cannula body which is flexbile and kin-resistant; *thin wall and tapered construction maximizes flow rates; *with tip orientation line permits precise insterting; *with vented or non-vented connector; *straight or curved tip, with fixed or adjusted ring *used during open heat surgery to build extracorporeal circuit
  • 3.
    CE 0197 Suckerfor Heart Surgery • Application It is used for attracting blood in the operating area in cardiac operation to ensure a clear vision.
  • 4.
    CE 0197 Ventsfor Open Heart Surgery • Application In cardiac operation, it is used for attracting the blood in left atrium through a trial sepal or upper lung vein, inserting in left atrium.
  • 5.
    Antegrade/Aortic Root/Perfusion/Cardioplegia Cannula • Application Incardiac operation, the perfusion cannula is inserted into root of aorta which cold arrest liquid perfused. Features 1. Proprietary center vented needle helps control blood flow while venting; 2. Designed with a soft tip to be atraumatic to the aorta; 3. It is flexible and convenient in inserting; 4. Antigrade perfusion 5. Variety of cardioplegia delivery options for today's challenging patients.
  • 6.
    Coronary Artery OstialCannula with CE Approved • Features 1. Antegrade; 2. Coronary artery ostial cannula; 3. Basket tip with high- flow 4. 90° & 45°
  • 7.
    Aortic Root Cannulawith Ventline • Application: In cardiac operation, the perfusion cannula is inserted into root of aorta which cold arrest liquid perfused. Features: 1. Proprietary center vented needle helps control blood flow while venting; 2. Designed with a soft tip to be atraumatic to the aorta; 3. It is flexible and convenient in inserting; 4. With ventline; 5. Antegrade perfusion;
  • 8.
    PVC/Disposable/Stopcock/Aortic Root Cannula • Application Incardiac operation, the perfusion cannula is inserted into root of aorta which cold arrest liquid perfused. Features 1. Proprietary center vented needle helps control blood flow while venting; 2. Designed with a soft tip to be atraumatic to the aorta; 3. It is flexible and convenient in inserting; 4. Straight type with high-flow stopcock 5. Antigrade perfusion
  • 9.
    Single Stage VenousCannula with Ce • Application In cardiac operation under direct vision, it can be inserted into the vein for blood flow in extracorporeal circulation. 1. Kink resists wire-wound reinforced body 2. Fflexible body enables easy positioning; 3. Thin wall construction maximizes flow rates