SlideShare a Scribd company logo
1 of 10
Download to read offline
VS525Z Tech Sheet

 Balboa
 System PN 55666

 System Model # VSP-VS525-BCAH
 Software Version # 43
 EPN # 3141

 Base PCBA - PN 55667
 PCB VS500Z - PN 22972 Rev E

 Base Panels
 VL2XX Series
 VL4XX Series
 See page 9 and 10.

 Aux Panel
 VX10 – PN 55608
 (required for Blower operation)




 Template used: 40600_T.pdf 02/19/09
 55666_97_A.pdf 02/23/09



http://www.MyPoolSpas.com              Wholesale Pool and Spa Parts
                                                 Page 1                920-925-3094
                                                                      VS525Z - 55666_97_A
System Revision History
System PN EPN             Date      Requested By                             Changes Made
55666          3141 02-20-09        Balboa         New system similar to VS520Z that allows disabling Pump 2




        http://www.MyPoolSpas.com             Wholesale Pool and Spa Parts
                                                        Page 2                                     920-925-3094
                                                                                                  VS525Z - 55666_97_A
Basic System Features and Functions

 Power Requirements



 System Outputs
 Setup 1 (As Manufactured)   Setup 2




                                         (Stereo)
              (Stereo)

                             Optional Devices
 Optional Devices




                                                                                                                                 FUSE
 Additional Options                                 K8                                   W2
                                                                                                              K5
                                                                                  W3
                                                                         J1 J1A
                                                                                                                          J10



                                                                                J2A
                                                                                                                                J18




                                                                                                              2 3
                                                                                                         1
                                                                                                    U4       J12

                                                         J2



                                                                                                                                J13
                                                                                             BALBOA INSTRUMENTS, INC. 2-SPD
                                                     J60       J22                       J44 VS500Z                   EXT RLY
                                                                        J7       J8
                                                                                             P/N 22972 REV D


                                                     EXT.     AUX. F                     VAC MADE IN U.S.A
                                                     RLY               SEN. A   SEN. B        COPYRIGHT 2005




http://www.MyPoolSpas.com       Wholesale Pool and Spa Parts
                                          Page 3                                                                     920-925-3094
                                                                                                                    VS525Z - 55666_97_A
Basic System Features and Functions
Any time you change a DIP Switch, other than A1, you must reset Persistent                                                                                                           Power Up Display Sequence
Memory for your new DIP Switch Settings changes to take effect. If you do                                                                                                            Upon power up, you should see the following on the display:
not reset Persistent Memory, your system may function improperly.                                                                                                                       Three numbers in a row, which are the SSID (the System Software
                                                                                                                                                                                        ID). The third display of these numbers is the Software Version,
To reset Persistent Memory:                                                                                                                                                             which should match the version of your system. For example, if these
     Power down by disconnecting power source from spa.                                                                                                                                 three numbers are                    , that is a VS511SZ at version 38.
     Put a jumper across J43, covering both pins. (See illustration below)                                                                                                              Displayed next is: “ ” (indicating the system is configured for
     Power up by connecting power source to spa.                                                                                                                                        a heater between 3 and 6 kW) or “ ” (indicating the system is
     Wait until “ ” is displayed on your panel.                                                                                                                                         configured for a heater effectively* between 1 and 3 kW).
     Power down again.                                                                                                                                                                  “ ” should appear for all VS models running at 240VAC.
     Remove jumper from J43 (May also move to cover 1 pin only)                                                                                                                         “ ” should appear for all VS models running at 120VAC, as well
                                                                                                                                                                                        as all GS models. (*A heater which is rated at 4 kW at 240VAC will
     Power up again.
                                                                                                                                                                                        function as a 1 kW heater at 120VAC.)
                                                                                                                                                                                        “ ” will appear to signal the start of Priming Mode.
About Persistent Memory and Time of Day Retention:
This system uses memory that doesn’t require a battery to store a variety of
                                                                                                                                                                                     At this point, the power up sequence is complete. Refer to the Reference
settings. What we refer to as Persistent Memory stores the filter settings,
                                                                                                                                                                                     Card for the VS or GS System model of your spa for information about how
the set temperature, and the heat mode.
                                                                                                                                                                                     the spa operates from this point on, including how to adjust the Time of
                                                                                                                                                                                     Day if using a Serial Deluxe style panel.
Persistent Memory is not used for Time of Day. Only models with a
Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the
time. However, during power loss to the spa, the system will lose the
correct time, and reset to 12:00 PM when power is restored.

                                                           J43


                                                                                                                                                                                                                                                                                  TST                                RST
                                                                                    FUSE 20A 250V                            J47                                                                                                                                                                          J6 J43
                                                                                                                     J46




                                                                       F7                                                                 J29
            K6   J23                                 J50                                                                                                                                                                                   PUMP                  OZONE
                               K1                                                                                                                                                                                                                      J23                 J29
                                                                                                                                                                F1                                                                                                                                                                        F5, F3A 250V                     J20
                                                                                                                                                        J20
                                                                          J17/26




                                                                  J6
  E.GND




                                                                                                                                                                                                                                                   G




                                                                                                                                                                                                                                                                      G




                                                                                                                                                                                                                                                                                           K5
                                                                                                                                                                                              J90




                                                                                                                                                                                                                                                                                                                                                                       G     C
                                                                                                                                                                                                                                                   C




                                                                                                                                                                                                                                                                      C
                                                                                                                                                                      FUSE 3A 250V
                                                                                                                                                         C
                                                                                                                             C




                                                                                                                                              C
                     C




                                                                   C
                                                      C




                                                           S1 TST
                                                                                                                             G




                                                                                                                                                         G
                                                                                                                                              G




                                                                                                                                                                                              J50




                                                                              W7
                                       W4
                     G




                                                                   G
                                                     G




                                                                                                                                                                                                                                                                                                                                               J12
                              W1                                                        K8                                                     K5
  F4 FUSE .3A 250V
                              SWITCHBANK A
                                        T1                                    K9                                  W3
                                                                                                                             W2                                                                          K4      K1
                                                                                                                                                                                                                                                   SWITCHBANK A
                                                                                                             J1 J1A
                                                                                                                                                               J10
                                                                                                                                                                                                                                                                                                                                                                J18
                                                                                                                                                                                                                                                         F2                                                                                                           U4
                                                                                                                                                                                                                                                                                                                                               J13




                                                                                                                    J2A                                                                                       T0.25A 250V
                                                                                                                                                                                                                                                   NEUTRAL
                                                                                                                                                                                                                                                                      WHT AC                                                                                                     J1
                                                                                                                                                                     J18




                                                                                                                                                                                                    W1                                        J58        J57
                                                                                                                                          1       2 3
                         K3                                                                                                                                                                                                                                               K3
                                                                                                                                         U4   J12
                         K2
                                                                                             J2
                                                                                                                                                                                                                                           VS100
                                                                                                                                                                                                                      P/N 22964_B MADE IN U.S.A.




                                                                                                                                                                                            J26                                                                                                 F4
                                                                                                                                                                                                                  Balboa




                                                                             J43
                                                                                                                                                                                                                                 © 2006




                         F2                                                                                                                                                                 LINE
                                                                                                                                                                                                                                                                                      K2




                                                                                                                                                                     J13                                                                                                                                            TST             RST
                                                                                                                                                                                           BLK AC
                                                                                                                                  BALBOA INSTRUMENTS, INC. 2-SPD                                                                                                                                     S1                    J6 J43
                                                                                         J60       J22                        J44 VS500Z                   EXT RLY
                                                                                   J6                       J7        J8                                                                                                                                                                                                                       J7          J8
                                             E.GND




                                                                                                                                  P/N 22972 REV D
                                                                                                                                                                                                                                                                                 J9




                                                                            S1 TST       EXT.
                                                                                           T      AUX. F                      VAC MADE IN U.S.A
                                                                                                                              V
                                                           SWITCHBANK A                  RLY
                                                                                          L                SEN. A   SEN. B         COPYRIGHT 2005                                                                                                            HEATER
                                                                                                                                                                                                                                                               A
                                                                                                                                                                                                                                                                                                            SWITCHBANK A                      SEN. A     SEN. B



  J43 on VS5xxZ and VS300 Series Main Board Shown.                                                                                                                                          J43 on VS100/GS100 Series Main Board Shown.
  J43 on GS5xxZ Series is located in approximately the same position.




             http://www.MyPoolSpas.com                                                                                                                  Wholesale Pool and Spa Parts
                                                                                                                                                                  Page 4                                                                                                                                                       920-925-3094
                                                                                                                                                                                                                                                                                                                              VS525Z - 55666_97_A
Wiring Configuration and DIP Settings
         Setup 1 (As Manufactured)

                                                              )
  To enable Circ Pump, set DIP switch A9 to                                                                                    (Stereo)
  ON (up)..
                                                                                                                                    PCBA Rev D & E only.
                                                                                                                                    Black jumper required.                                     Ozone and Circ Pump must be same voltage.
                                                                                                                                    Do not remove.                                             Do not remove Fuse F7 (20A)
                                                                                                                               K1                                                             F7 FUSE 20A 250V                                    J47




                                                                                                                                                                                                                                         J46
                                                                                                                                                                             W10                                                                                      J29
             CLASS G FUSE 30A                                     BLK AC                          K6 J23                                                     J50
                                                    F5            J61    J62                                            J74




                                                                                                                                                                                                                                              Circ.Pump
                                                                                                                                                                                                                                                                                               F1




                                                                                                                                                         Audio Visual
                                                                                                        2-Spd P1                                                                                                                                                                        J20




                                                                                                                                                                                          J17/26




                                                                                                                                                                                                                                                                    Ozone
                                                                                                                                                                                 Blower




                                                                                                                                                                                                                                                                                                     FUSE 3A 250V
                                         WHT AC
                                           T




                                                                                                                                                                                                                                                                                          C
                                                                                                                         J73




                                                                                                                                                                                                                                                                                       Light
                                                                                                                                                                                                                                                    C




                                                                                                                                                                                                                                                                             C


                                                                                                                                                                                                                                                                                       12V
                                                                                                               C




                                                                                                                                                                                     C
                                                                                                                                                                 C




                                                                                                                                                                                                                                                    G




                                                                                                                                                                                                                                                                                         G
                                                                                                                                                                                                                                                                             G
                                                                                                                                                                                               W7




                                                                                                                                             W4
                                                                                                               G




                                                                                                                                                                                     G
                                                                                                                                                                 G
                           J11    J15    J16 J25 J63 J64
             J66 J65
                                                                                                                        W1                                                                              K8                                                                    K5
                                                                                                                                                                                                                                                    W2
                                                                                                                                                T1                                             K9                                         W3
                                        NEUTRAL




                                                                                      F4 FUSE .3A 250V                                                                                                                                  J1A
                                         WHITE




                                                                                                                                                                                                                             J1
                                                                                                                                                                                                                                                                                               J10
                                        BLACK
                                         HOT




                                                                                                                                                                                                                                        J2A
                                                                                                                                                                                                                                                                   VS5xxS mode




                                                                                                                                                                                                                                                                                                     J18
                 TORQUE
                 RANGE
                                        RED
                                        HOT




                                                                                                                                                                                                                                                                                 2 3
                 FOR TB1:                                                                                          K3                                                                                                                                                    1
        K4       27-30 IN. LBS.                                                                                                                                                                                                                                     U4       J12
                                                                                                                   K2
                                                                        TB1                                                                                                                                  J2
                                   J32 J33 J34          J35                                                                                                                                   J43

                                   J36            J37                                                              F2
                                         RED AC                                                                                                                                                                                                                                                     J13
                                                                                                                                                                                                                                                              BALBOA INSTRUMENTS, INC. 2-SPD
                                                                                                                                                                                                         J60       J22                                    J44 VS500Z                   EXT RLY
                                                                                                                                                                                                                            J7           J8

                   Balboa                                 HTR2                 HTR1                                                                                                                J6
                                                                                                                                                     E.GND




                                                                                                                                                                                                                                                              P/N 22972 REV D


                          J100                                    J101                                                                                                                        S1 TST     EXT.     AUX. F                              VAC MADE IN U.S.A
                                                                                                                                                                        SWITCHBANK A                     RLY               SEN. A       SEN. B                COPYRIGHT 2005



                                                              5.5 kW
                                                                                                                                             X-P332
                                                                                                                                             PN 55137                                                        J7
                                                                                               J1
                                                                                                    2-Spd P2
                                                                                                    R




                                                                                                                                                P/N 22909 REV B
                                                                                             W1
                                                                                                      B




                                                                                                                                                                        J6
                                                                                                         W G




                                                                                                                               F30A 480V




WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.
WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)

                                                                                                                                           VS51x/VS5xxS/VS5xxD
SSID #                                                                                                                                          Compatible
                                                                                                                                                                                                                                    Wiring Color Key
                                                                                                                                                                                                                                                                                       120 Volt Connections
 100                                                                                                                                      J12                                                                                                                                          240 Volt Connections
  57                                                                                                                                                         1               2            3                                                                                            Black AC Jumpers
  43                                                                                                                                                                                                                                                                                   12 Volt Connections
              A1, Test Mode OFF
                                                                                                                                                                                                                                                                                       Relay Control Wires
              A2, See Table 1                                                     A7, Mode changes allowed
                                                                                                                                                         J43                                                                        Board Connector Key
                                                                                                                                                                             Memory
                                                                                  A9, Non-Circ Mode
              A5, 2-speed P2
                  P2 Disabled                                                                                                                                                Reset                                                  1                        Typically Line voltage
                                                                                  A10, See Table 1
                                                                                                                                                                                                                                    2                        Typically Line voltage for 2-speed pumps
Panel Button Assignments                                                                            Panel Button Positions                                                                                                          3                        Neutral (Common)
1=Pump 2               4=Light                                                                                                        1                                                                                             4                        Ground
2=Pump 1               Aux=J17/26                                               1     2                   3              4                                              3                     A
3=Temp                                                                                                                                4     2
                                                                                                                                                                                                                                                             Note flat sides in connector


       http://www.MyPoolSpas.com                                                                               Wholesale Pool and Spa Parts
                                                                                                                         Page 5                                                                                                                                                          920-925-3094
                                                                                                                                                                                                                                                                                        VS525Z - 55666_97_A
Wiring Configuration and DIP Settings
         Setup 2
                                                              )
  To enable Circ Pump, set DIP switch A9 to
  ON (up)..
                                                                                                                             (Stereo)
                                                                                                                                  PCBA Rev D & E only.
                                                                                                                                  Black jumper required.                                           Ozone and Circ Pump must be same voltage.
                                                                                                                                  Do not remove.                                                   Do not remove Fuse F7 (20A)
                                                                                                                             K1                                                                  F7 FUSE 20A 250V                                          J47




                                                                                                                                                                                                                                                  J46
                                                                                                                                                                                 W10                                                                                           J29
             CLASS G FUSE 30A                                     BLK AC                        K6 J23                                                      J50
                                                    F5            J61    J62                                        J74




                                                                                                                                                                                                                                                       Circ.Pump
                                                                                                                                                                                                                                                                                                        F1




                                                                                                                                                        Audio Visual
                                                                                                    2-Spd P1                                                                                                                                                                                     J20




                                                                                                                                                                                              J17/26




                                                                                                                                                                                                                                                                             Ozone
                                                                                                                                                                                    Blower
                                                                                                                                                                                    Blower




                                                                                                                                                                                                                                                                                                              FUSE 3A 250V
                                         WHT AC
                                           T




                                                                                                                                                                                                                                                                                                   C
                                                                                                                       J73




                                                                                                                                                                                                                                                                                                Light
                                                                                                                                                                                                                                                             C




                                                                                                                                                                                                                                                                                      C


                                                                                                                                                                                                                                                                                                12V
                                                                                                         C




                                                                                                                                                                                         C
                                                                                                                                                                C




                                                                                                                                                                                                                                                             G




                                                                                                                                                                                                                                                                                                  G
                                                                                                                                                                                                                                                                                      G
                                                                                                                                                                                                  W7




                                                                                                                                            W4
                                                                                                         G




                                                                                                                                                                                         G
                                                                                                                                                                G
                           J11    J15    J16 J25 J63 J64
             J66 J65
                                                                                                                    W1                                                                                      K8                                                                         K5
                                                                                                                                                                                                                                                             W2
                                                                                                                                               T1                                                 K9                                               W3
                                        NEUTRAL




                                                                                      F4 FUSE .3A 250V                                                                                                                                           J1A
                                         WHITE




                                                                                                                                                                                                                                      J1
                                                                                                                                                                                                                                                                                                        J10
                                        BLACK
                                         HOT




                                                                                                                                                                                                                                                 J2A
                                                                                                                                                                                                                                                                            VS51x mode




                                                                                                                                                                                                                                                                                                              J18
                 TORQUE
                 RANGE
                                        RED
                                        HOT




                                                                                                                                                                                                                                                                                          2 3
                 FOR TB1:                                                                                      K3                                                                                                                                                                 1
        K4       27-30 IN. LBS.                                                                                                                                                                                                                                              U4       J12
                                                                                                               K2
                                                                        TB1                                                                                                                                      J2
                                   J32 J33 J34          J35                                                                                                                                      J43

                                   J36            J37                                                          F2
                                         RED AC                                                                                                                                                                                                                                                              J13
                                                                                                                                                                                                                                                                       BALBOA INSTRUMENTS, INC. 2-SPD
                                                                                                                                                                                                             J60       J22                                         J44 VS500Z                   EXT RLY
                                                                                                                                                                                                                                     J7           J8

                   Balboa                                 HTR2                 HTR1                                                                                                                    J6
                                                                                                                                                    E.GND




                                                                                                                                                                                                                                                                       P/N 22972 REV D


                          J100                                    J101                                                                                                                           S1 TST      EXT.     AUX. F                                   VAC MADE IN U.S.A
                                                                                                                                                                            SWITCHBANK A                     RLY                    SEN. A       SEN. B                COPYRIGHT 2005



                                                              5.5 kW
                                                                                                                                                               X-P332
                                                                                                                                                               PN 55137                                                        J7
                                                                                                         J1
                                                                                                                2-Spd P2
                                                                                                                R
                                                                                                                  UnusedG




                                                                                                                                                                       P/N 22909 REV B
                                                                                                    W1
                                                                                                                   B




                                                                                                                                                                                         J6
                                                                                                                     W




                                                                                                                                        F30A 480V




WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.
WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)

                                                                                                                                          VS51x/VS5xxS/VS5xxD
SSID #                                                                                                                                         Compatible
                                                                                                                                                                                                                                             Wiring Color Key
                                                                                                                                                                                                                                                                                                120 Volt Connections
 100                                                                                                                                     J12                                                                                                                                                    240 Volt Connections
  57                                                                                                                                                        1                   2            3                                                                                                  Black AC Jumpers
  43                                                                                                                                                                                                                                                                                            12 Volt Connections
              A1, Test Mode OFF
                                                                                                                                                                                                                                                                                                Relay Control Wires
              A2, See Table 1                                                     A7, Mode changes allowed
                                                                                                                                                        J43                                                                                  Board Connector Key
                                                                                                                                                                                  Memory
                                                                                  A9, Non-Circ Mode
              A5, P2 Disabled                                                                                                                                                     Reset                                                      1                        Typically Line voltage
                                                                                  A10, See Table 1
                                                                                                                                                                                                                                             2                        Typically Line voltage for 2-speed pumps
Panel Button Assignments                                                                         Panel Button Positions                                                                                                                      3                        Neutral (Common)
1=Pump 2               4=Light                                                                                                      1                                                                                                        4                        Ground
2=Pump 1               Aux=J17/26                                               1     2              3                4                                                    3                     A
3=Temp                                                                                                                              4      2
                                                                                                                                                                                                                                                                      Note flat sides in connector


       http://www.MyPoolSpas.com                                                                          Wholesale Pool and Spa Parts
                                                                                                                    Page 6                                                                                                                                                                        920-925-3094
                                                                                                                                                                                                                                                                                                 VS525Z - 55666_97_A
DIP Switches and Jumpers Definitions
   SSID 100 57 43                                                             Base Model VS525Z
DIP Switch Key
     A1 Test Mode (normally OFF)                                                                 Table 1         # of Hi-Speed
A2+A10 Control amp draw requirements (See Table 1)                                                               Pumps/Blower
     A3 “ON” position: use Mini Panel                                                                         Before Heat Disabled
         “OFF” position: use Digital Duplex or Light Duplex panel                                 A2       A10
     A4 Aux Freeze (must be OFF)
     A5 “ON” position: 2-Speed Pump 2 enabled on expander board                                  OFF       OFF           0
         “OFF” position: Pump 2 disabled                                                         ON        OFF           1
     A6 “ON” position: 50Hz operation                                                            OFF       ON            2
         “OFF” position: 60Hz operation                                                          ON        ON            3
     A7 “ON” position: Standard mode only
         “OFF” position: Std/Ecn/Sleep mode changes allowed
     A8 “ON” position: temperature is displayed in degrees Celsius
                                                                                                Alert:
                                                                                                Pump 2 (if enabled) must be
         “OFF” position: temperature is displayed in degrees Fahrenheit
                                                                                                2-speed, and uses the X-P332
     A9 Pump 1 speeds and Circ Modes:
                                                                                                expander board.
             A9     Circ Mode                                   Pump 1 Speed                    To add Blower or 1-speed Pump 3,
            OFF    Non-circ                                     2-speed                         use J17/26 and 1-button Aux Panel.
            ON     24 hours with 3°F shut-off                   2-speed
Note: Panel layout is always Pump 2 (or Unused), Pump 1, Temp, Light, with optional Blower or Pump 3 on 1-button Aux Panel.**
** J2 connector on main board must be a 6-pin connector to use Aux Panel. IR Receiver is not compatible.

Jumper Key
J12     Factory set. DO NOT MOVE.
        Jumper must be on Pins 1 and 2 for VS51xZ/VS52xZ/VS5xxSZ/VS5xxDZ software.
        Jumper must be on Pins 2 and 3 for VS50xZ software.
J43     When jumper is placed on 2 pins during power-up, system will reset persistent memory.
        Leave on 1 pin only to enable persistent memory feature.
 WARNING:
  Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components.
  Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
  Contact Balboa if you require additional configuration pages added to this tech sheet.



                                       Panel Button Positions
                                                                                   1
                        A3: OFF       1         2                3        4                            3          A
                                                                                   4    2


                        A3:ON                         1     2     3       4            A



                                    Panel Button Assignments
                                     1=Pump 2 (A5 On)* 3=Temp                      Aux=J17/26
                                     2=Pump 1          4=Light
                                     *1=Unused (A5 Off)

 http://www.MyPoolSpas.com                          Wholesale Pool and Spa Parts
                                                              Page 7                                               920-925-3094
                                                                                                                  VS525Z - 55666_97_A
Ozone Connections
Ozone Connector Voltage: The VS500Z circuit board is factory configured to deliver a preset voltage (120V or
240V) to the on-board ozone connector (J29). See the ratings table on the wiring diagram attached to the cover
of the enclosure for the configured voltage. For 240V output W2 connects to Red AC and for 120V output W2
connects to White AC.

The voltage to the ozone connector can be changed in the field if required. W2 just needs to be set for the
required voltage.

WARNING: Changing the voltage of the ozone connector also effects the voltage supplied to the circ
pump connector (J47). Any equipment controlled by that connector may be damaged if the wrong voltage
is selected.

Balboa Ozone Generator: If the board is set up to operate a 120V ozone generator, the connector on the ozone
generator is likely to be configured correctly, but should be compared to the illustration below.

If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the connector next
to the green ground wire as described below.

Note: A special tool is required to remove the pins from the connector body once they are snapped in place.
Check with your Balboa Account Manager for information on purchasing a pin-removal tool.

 Balboa Ozone connector configuration for 120V 60Hz                                                B
                                           Line - Black conductor
                    Use this slot for the leftover Red conductor
      Common - Install the White conductor here for 120V ozone
                                                                                                         G
                                      Ground (Green) conductor

                                                                                        Flat sides of sockets as shown
 Balboa Ozone connector configuration for 240V 60Hz                                                B
                                           Line - Black conductor
                   Use this slot for the leftover White conductor
        Common - Install the Red conductor here for 240V ozone
                                                                                                         G
                                       Ground (Green) conductor



FUSE 20A 250V               J47
                      J46




                                     J29
                                                                          Line - Black conductor
                         Circ.Pump
                              R




                                              J20     F1                  Use this slot for the leftover conductor
                              B




                                                                          Common - Red for 240V or White for 120V ozone (See W2 wire)
                                                                          Ground (Green) conductor
                                                           FUSE 3A 250V
                                               W
                                             Light
                              W




                                             12V




                                                                          W2 wire determines voltage
                                               W
                              G




 K8                                     K5
                              W2
                       W3
                J1 J1A
                                                     J10


       http://www.MyPoolSpas.com                     Wholesale Pool and Spa Parts
                                                               Page 8                                               920-925-3094
                                                                                                                   VS525Z - 55666_97_A
Duplex Panel Configurations

                                                                                VL200 (LCD Lite Digital)
                                                                                VL20
                                                                                PN 52312 with Overlay PN 11127
                                                                                   5
                                                                                 Co
                                                                                 Connects to Main Board terminal J1
                                                                                 DIP Switch A3 must be on




                                                                             VL240 (MVP240)
                                 Jets 2 Jets 1 Temp Light                    PN 55569 with Overlay PN 11764 (Gray Plastic)
                                                                             PN 53636 with no O/L (White Plastic)
                                                                              Connects to Main Board terminal J1
                                                                              DIP Switch A3 must be on


                                                                                            VL260 (MVP260)
                                                                                            Overlay PN 11725
                                             Jets   Jets    Temp Light
                                                                                            PN 55049 with White Plastic
                                                                                            PN 55050 with Gray Plastic
                                                                                            PN 55051 with Clear Plastic
                                                                                             Connects to Main Board terminal J1
DUPLEX




                                                                                             DIP Switch A3 must be on




                                                                                                 VL400
                                                                                                 PN 55129 with Overlay PN 11822
                                                                                                  Connects to Main Board terminal J1
                                                                                                  DIP Switch A3 must be off




                                                                                       VL401 (LCD Lite Digital)
                                                                                       PN 54251-01 with Overlay PN 11671
                                                                                        Connects to Main Board terminal J1
                                                                                        DIP Switch A3 must be off




         http://www.MyPoolSpas.com                          Wholesale Pool and Spa Parts
                                                                      Page 9                                    920-925-3094
                                                                                                               VS525Z - 55666_97_A
Duplex Panel Configurations


                                                                              VL402 (LCD Super Duplex)
                                                                              PN 54107 with Overlay PN 10764
                                                                               Connects to Main Board terminal J1
                                                                               DIP Switch A3 must be off




                                                                              VL403 (LED Lite Digital)
                                                                              PN 54104 with Overlay PN 10752
                                                                               Connects to Main Board terminal J1
DUPLEX




                                                                               DIP Switch A3 must be off




                                                                              VL404 (LED Digital Duplex)
                                                                              PN 51248 with Overlay PN 10418
                                                                               Connects to Main Board terminal J1
                                                                               DIP Switch A3 must be off




                                     VX10
AUX




                                     PN 55608 with Overlay PN 40107
                                      Required for Blower
                  Blower
                  Jets 1              Connects to Main Board terminal J2




         http://www.MyPoolSpas.com             Wholesale Page and Spa Parts
                                                         Pool 10                                      920-925-3094
                                                                                                     VS525Z - 55666_97_A

More Related Content

What's hot

What's hot (17)

54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah
 
55370 01 vsp_vs504_sz_dcaj
55370 01 vsp_vs504_sz_dcaj55370 01 vsp_vs504_sz_dcaj
55370 01 vsp_vs504_sz_dcaj
 
54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah
 
54635 01 vsp_vs503_sz_dcah
54635 01 vsp_vs503_sz_dcah54635 01 vsp_vs503_sz_dcah
54635 01 vsp_vs503_sz_dcah
 
55106 gs5 gs510_dz_rca_30
55106 gs5 gs510_dz_rca_3055106 gs5 gs510_dz_rca_30
55106 gs5 gs510_dz_rca_30
 
56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah
 
54639 01 vsp_vs514_sz_ycah
54639 01 vsp_vs514_sz_ycah54639 01 vsp_vs514_sz_ycah
54639 01 vsp_vs514_sz_ycah
 
54637 01 vsp_vs504_sz_dcah
54637 01 vsp_vs504_sz_dcah54637 01 vsp_vs504_sz_dcah
54637 01 vsp_vs504_sz_dcah
 
54368 03 vsp_vs500_z_ccah
54368 03 vsp_vs500_z_ccah54368 03 vsp_vs500_z_ccah
54368 03 vsp_vs500_z_ccah
 
55421 01 gs5_gs520_dz_rca-30
55421 01 gs5_gs520_dz_rca-3055421 01 gs5_gs520_dz_rca-30
55421 01 gs5_gs520_dz_rca-30
 
54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj
 
54519 02 gs5_gs511_z_rca-30
54519 02 gs5_gs511_z_rca-3054519 02 gs5_gs511_z_rca-30
54519 02 gs5_gs511_z_rca-30
 
54763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-3054763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-30
 
55896 gs5 gs513_z_rca_30
55896 gs5 gs513_z_rca_3055896 gs5 gs513_z_rca_30
55896 gs5 gs513_z_rca_30
 
54650 01 gs5_gs504_sz_rca-30
54650 01 gs5_gs504_sz_rca-3054650 01 gs5_gs504_sz_rca-30
54650 01 gs5_gs504_sz_rca-30
 
54752 01 gs5_gs520_sz_rca-30
54752 01 gs5_gs520_sz_rca-3054752 01 gs5_gs520_sz_rca-30
54752 01 gs5_gs520_sz_rca-30
 
55461 01 gs5_gs504_sz_rca-30
55461 01 gs5_gs504_sz_rca-3055461 01 gs5_gs504_sz_rca-30
55461 01 gs5_gs504_sz_rca-30
 

Similar to 55666 vsp vs525_bcah (16)

56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah
 
54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah
 
54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah
 
54356 0320 vsp_vs501z_ccah
54356 0320 vsp_vs501z_ccah54356 0320 vsp_vs501z_ccah
54356 0320 vsp_vs501z_ccah
 
54379 03 vsp_vs501_z_ccaj
54379 03 vsp_vs501_z_ccaj54379 03 vsp_vs501_z_ccaj
54379 03 vsp_vs501_z_ccaj
 
54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj
 
54481 03 vsp_vs501_z_ccaj
54481 03 vsp_vs501_z_ccaj54481 03 vsp_vs501_z_ccaj
54481 03 vsp_vs501_z_ccaj
 
55508 vsp vs501_sz_azaj
55508 vsp vs501_sz_azaj55508 vsp vs501_sz_azaj
55508 vsp vs501_sz_azaj
 
55250 01 gs5_gs501_dz_rca-30
55250 01 gs5_gs501_dz_rca-3055250 01 gs5_gs501_dz_rca-30
55250 01 gs5_gs501_dz_rca-30
 
54751 01 gs5_gs520_dz_rca-30
54751 01 gs5_gs520_dz_rca-3054751 01 gs5_gs520_dz_rca-30
54751 01 gs5_gs520_dz_rca-30
 
54848 gs5 gs525_z_rca_30k
54848 gs5 gs525_z_rca_30k54848 gs5 gs525_z_rca_30k
54848 gs5 gs525_z_rca_30k
 
55509 gs5 gs501_z_rca_20
55509 gs5 gs501_z_rca_2055509 gs5 gs501_z_rca_20
55509 gs5 gs501_z_rca_20
 
55423 01 gs5_gs520_sz_rca-30
55423 01 gs5_gs520_sz_rca-3055423 01 gs5_gs520_sz_rca-30
55423 01 gs5_gs520_sz_rca-30
 
54521 02 gs5_gs511_sz_rca-30
54521 02 gs5_gs511_sz_rca-3054521 02 gs5_gs511_sz_rca-30
54521 02 gs5_gs511_sz_rca-30
 
55471 gs5 gs501_z_rca_30
55471 gs5 gs501_z_rca_3055471 gs5 gs501_z_rca_30
55471 gs5 gs501_z_rca_30
 
55613 gs5 gs501_z_rca_15
55613 gs5 gs501_z_rca_1555613 gs5 gs501_z_rca_15
55613 gs5 gs501_z_rca_15
 

More from Accurate Pool & Spa Services, llc

More from Accurate Pool & Spa Services, llc (20)

Ultimate spaside instruction sheet
Ultimate spaside instruction sheetUltimate spaside instruction sheet
Ultimate spaside instruction sheet
 
Standard spaside instruction sheet
Standard spaside instruction sheetStandard spaside instruction sheet
Standard spaside instruction sheet
 
Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2
 
Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2
 
Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2
 
Hq label wd highlight
Hq label wd highlightHq label wd highlight
Hq label wd highlight
 
Eco 3 spaside instruction sheet
Eco 3 spaside instruction sheetEco 3 spaside instruction sheet
Eco 3 spaside instruction sheet
 
Eco 2 spaside instruction sheet
Eco 2 spaside instruction sheetEco 2 spaside instruction sheet
Eco 2 spaside instruction sheet
 
Eco 1 spaside instruction sheet
Eco 1 spaside instruction sheetEco 1 spaside instruction sheet
Eco 1 spaside instruction sheet
 
Eco 2 pcb revisions
Eco 2 pcb revisionsEco 2 pcb revisions
Eco 2 pcb revisions
 
Eco 1 programming
Eco 1 programmingEco 1 programming
Eco 1 programming
 
Deluxe spaside instruction sheet
Deluxe spaside instruction sheetDeluxe spaside instruction sheet
Deluxe spaside instruction sheet
 
Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07
 
Cs9700 llp settings 3 07
Cs9700 llp settings 3 07Cs9700 llp settings 3 07
Cs9700 llp settings 3 07
 
Control cord colors
Control cord colorsControl cord colors
Control cord colors
 
850077 a outdoor operation
850077 a outdoor operation850077 a outdoor operation
850077 a outdoor operation
 
9400 9600 programming
9400 9600 programming9400 9600 programming
9400 9600 programming
 
9300 programming
9300 programming9300 programming
9300 programming
 
85 0138 infrared remote-web
85 0138 infrared remote-web85 0138 infrared remote-web
85 0138 infrared remote-web
 
85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web
 

55666 vsp vs525_bcah

  • 1. VS525Z Tech Sheet Balboa System PN 55666 System Model # VSP-VS525-BCAH Software Version # 43 EPN # 3141 Base PCBA - PN 55667 PCB VS500Z - PN 22972 Rev E Base Panels VL2XX Series VL4XX Series See page 9 and 10. Aux Panel VX10 – PN 55608 (required for Blower operation) Template used: 40600_T.pdf 02/19/09 55666_97_A.pdf 02/23/09 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 1 920-925-3094 VS525Z - 55666_97_A
  • 2. System Revision History System PN EPN Date Requested By Changes Made 55666 3141 02-20-09 Balboa New system similar to VS520Z that allows disabling Pump 2 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 2 920-925-3094 VS525Z - 55666_97_A
  • 3. Basic System Features and Functions Power Requirements System Outputs Setup 1 (As Manufactured) Setup 2 (Stereo) (Stereo) Optional Devices Optional Devices FUSE Additional Options K8 W2 K5 W3 J1 J1A J10 J2A J18 2 3 1 U4 J12 J2 J13 BALBOA INSTRUMENTS, INC. 2-SPD J60 J22 J44 VS500Z EXT RLY J7 J8 P/N 22972 REV D EXT. AUX. F VAC MADE IN U.S.A RLY SEN. A SEN. B COPYRIGHT 2005 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 3 920-925-3094 VS525Z - 55666_97_A
  • 4. Basic System Features and Functions Any time you change a DIP Switch, other than A1, you must reset Persistent Power Up Display Sequence Memory for your new DIP Switch Settings changes to take effect. If you do Upon power up, you should see the following on the display: not reset Persistent Memory, your system may function improperly. Three numbers in a row, which are the SSID (the System Software ID). The third display of these numbers is the Software Version, To reset Persistent Memory: which should match the version of your system. For example, if these Power down by disconnecting power source from spa. three numbers are , that is a VS511SZ at version 38. Put a jumper across J43, covering both pins. (See illustration below) Displayed next is: “ ” (indicating the system is configured for Power up by connecting power source to spa. a heater between 3 and 6 kW) or “ ” (indicating the system is Wait until “ ” is displayed on your panel. configured for a heater effectively* between 1 and 3 kW). Power down again. “ ” should appear for all VS models running at 240VAC. Remove jumper from J43 (May also move to cover 1 pin only) “ ” should appear for all VS models running at 120VAC, as well as all GS models. (*A heater which is rated at 4 kW at 240VAC will Power up again. function as a 1 kW heater at 120VAC.) “ ” will appear to signal the start of Priming Mode. About Persistent Memory and Time of Day Retention: This system uses memory that doesn’t require a battery to store a variety of At this point, the power up sequence is complete. Refer to the Reference settings. What we refer to as Persistent Memory stores the filter settings, Card for the VS or GS System model of your spa for information about how the set temperature, and the heat mode. the spa operates from this point on, including how to adjust the Time of Day if using a Serial Deluxe style panel. Persistent Memory is not used for Time of Day. Only models with a Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the time. However, during power loss to the spa, the system will lose the correct time, and reset to 12:00 PM when power is restored. J43 TST RST FUSE 20A 250V J47 J6 J43 J46 F7 J29 K6 J23 J50 PUMP OZONE K1 J23 J29 F1 F5, F3A 250V J20 J20 J17/26 J6 E.GND G G K5 J90 G C C C FUSE 3A 250V C C C C C C S1 TST G G G J50 W7 W4 G G G J12 W1 K8 K5 F4 FUSE .3A 250V SWITCHBANK A T1 K9 W3 W2 K4 K1 SWITCHBANK A J1 J1A J10 J18 F2 U4 J13 J2A T0.25A 250V NEUTRAL WHT AC J1 J18 W1 J58 J57 1 2 3 K3 K3 U4 J12 K2 J2 VS100 P/N 22964_B MADE IN U.S.A. J26 F4 Balboa J43 © 2006 F2 LINE K2 J13 TST RST BLK AC BALBOA INSTRUMENTS, INC. 2-SPD S1 J6 J43 J60 J22 J44 VS500Z EXT RLY J6 J7 J8 J7 J8 E.GND P/N 22972 REV D J9 S1 TST EXT. T AUX. F VAC MADE IN U.S.A V SWITCHBANK A RLY L SEN. A SEN. B COPYRIGHT 2005 HEATER A SWITCHBANK A SEN. A SEN. B J43 on VS5xxZ and VS300 Series Main Board Shown. J43 on VS100/GS100 Series Main Board Shown. J43 on GS5xxZ Series is located in approximately the same position. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 4 920-925-3094 VS525Z - 55666_97_A
  • 5. Wiring Configuration and DIP Settings Setup 1 (As Manufactured) ) To enable Circ Pump, set DIP switch A9 to (Stereo) ON (up).. PCBA Rev D & E only. Black jumper required. Ozone and Circ Pump must be same voltage. Do not remove. Do not remove Fuse F7 (20A) K1 F7 FUSE 20A 250V J47 J46 W10 J29 CLASS G FUSE 30A BLK AC K6 J23 J50 F5 J61 J62 J74 Circ.Pump F1 Audio Visual 2-Spd P1 J20 J17/26 Ozone Blower FUSE 3A 250V WHT AC T C J73 Light C C 12V C C C G G G W7 W4 G G G J11 J15 J16 J25 J63 J64 J66 J65 W1 K8 K5 W2 T1 K9 W3 NEUTRAL F4 FUSE .3A 250V J1A WHITE J1 J10 BLACK HOT J2A VS5xxS mode J18 TORQUE RANGE RED HOT 2 3 FOR TB1: K3 1 K4 27-30 IN. LBS. U4 J12 K2 TB1 J2 J32 J33 J34 J35 J43 J36 J37 F2 RED AC J13 BALBOA INSTRUMENTS, INC. 2-SPD J60 J22 J44 VS500Z EXT RLY J7 J8 Balboa HTR2 HTR1 J6 E.GND P/N 22972 REV D J100 J101 S1 TST EXT. AUX. F VAC MADE IN U.S.A SWITCHBANK A RLY SEN. A SEN. B COPYRIGHT 2005 5.5 kW X-P332 PN 55137 J7 J1 2-Spd P2 R P/N 22909 REV B W1 B J6 W G F30A 480V WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches. WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page) VS51x/VS5xxS/VS5xxD SSID # Compatible Wiring Color Key 120 Volt Connections 100 J12 240 Volt Connections 57 1 2 3 Black AC Jumpers 43 12 Volt Connections A1, Test Mode OFF Relay Control Wires A2, See Table 1 A7, Mode changes allowed J43 Board Connector Key Memory A9, Non-Circ Mode A5, 2-speed P2 P2 Disabled Reset 1 Typically Line voltage A10, See Table 1 2 Typically Line voltage for 2-speed pumps Panel Button Assignments Panel Button Positions 3 Neutral (Common) 1=Pump 2 4=Light 1 4 Ground 2=Pump 1 Aux=J17/26 1 2 3 4 3 A 3=Temp 4 2 Note flat sides in connector http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 5 920-925-3094 VS525Z - 55666_97_A
  • 6. Wiring Configuration and DIP Settings Setup 2 ) To enable Circ Pump, set DIP switch A9 to ON (up).. (Stereo) PCBA Rev D & E only. Black jumper required. Ozone and Circ Pump must be same voltage. Do not remove. Do not remove Fuse F7 (20A) K1 F7 FUSE 20A 250V J47 J46 W10 J29 CLASS G FUSE 30A BLK AC K6 J23 J50 F5 J61 J62 J74 Circ.Pump F1 Audio Visual 2-Spd P1 J20 J17/26 Ozone Blower Blower FUSE 3A 250V WHT AC T C J73 Light C C 12V C C C G G G W7 W4 G G G J11 J15 J16 J25 J63 J64 J66 J65 W1 K8 K5 W2 T1 K9 W3 NEUTRAL F4 FUSE .3A 250V J1A WHITE J1 J10 BLACK HOT J2A VS51x mode J18 TORQUE RANGE RED HOT 2 3 FOR TB1: K3 1 K4 27-30 IN. LBS. U4 J12 K2 TB1 J2 J32 J33 J34 J35 J43 J36 J37 F2 RED AC J13 BALBOA INSTRUMENTS, INC. 2-SPD J60 J22 J44 VS500Z EXT RLY J7 J8 Balboa HTR2 HTR1 J6 E.GND P/N 22972 REV D J100 J101 S1 TST EXT. AUX. F VAC MADE IN U.S.A SWITCHBANK A RLY SEN. A SEN. B COPYRIGHT 2005 5.5 kW X-P332 PN 55137 J7 J1 2-Spd P2 R UnusedG P/N 22909 REV B W1 B J6 W F30A 480V WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches. WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page) VS51x/VS5xxS/VS5xxD SSID # Compatible Wiring Color Key 120 Volt Connections 100 J12 240 Volt Connections 57 1 2 3 Black AC Jumpers 43 12 Volt Connections A1, Test Mode OFF Relay Control Wires A2, See Table 1 A7, Mode changes allowed J43 Board Connector Key Memory A9, Non-Circ Mode A5, P2 Disabled Reset 1 Typically Line voltage A10, See Table 1 2 Typically Line voltage for 2-speed pumps Panel Button Assignments Panel Button Positions 3 Neutral (Common) 1=Pump 2 4=Light 1 4 Ground 2=Pump 1 Aux=J17/26 1 2 3 4 3 A 3=Temp 4 2 Note flat sides in connector http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 6 920-925-3094 VS525Z - 55666_97_A
  • 7. DIP Switches and Jumpers Definitions SSID 100 57 43 Base Model VS525Z DIP Switch Key A1 Test Mode (normally OFF) Table 1 # of Hi-Speed A2+A10 Control amp draw requirements (See Table 1) Pumps/Blower A3 “ON” position: use Mini Panel Before Heat Disabled “OFF” position: use Digital Duplex or Light Duplex panel A2 A10 A4 Aux Freeze (must be OFF) A5 “ON” position: 2-Speed Pump 2 enabled on expander board OFF OFF 0 “OFF” position: Pump 2 disabled ON OFF 1 A6 “ON” position: 50Hz operation OFF ON 2 “OFF” position: 60Hz operation ON ON 3 A7 “ON” position: Standard mode only “OFF” position: Std/Ecn/Sleep mode changes allowed A8 “ON” position: temperature is displayed in degrees Celsius Alert: Pump 2 (if enabled) must be “OFF” position: temperature is displayed in degrees Fahrenheit 2-speed, and uses the X-P332 A9 Pump 1 speeds and Circ Modes: expander board. A9 Circ Mode Pump 1 Speed To add Blower or 1-speed Pump 3, OFF Non-circ 2-speed use J17/26 and 1-button Aux Panel. ON 24 hours with 3°F shut-off 2-speed Note: Panel layout is always Pump 2 (or Unused), Pump 1, Temp, Light, with optional Blower or Pump 3 on 1-button Aux Panel.** ** J2 connector on main board must be a 6-pin connector to use Aux Panel. IR Receiver is not compatible. Jumper Key J12 Factory set. DO NOT MOVE. Jumper must be on Pins 1 and 2 for VS51xZ/VS52xZ/VS5xxSZ/VS5xxDZ software. Jumper must be on Pins 2 and 3 for VS50xZ software. J43 When jumper is placed on 2 pins during power-up, system will reset persistent memory. Leave on 1 pin only to enable persistent memory feature. WARNING: Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components. Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system. Contact Balboa if you require additional configuration pages added to this tech sheet. Panel Button Positions 1 A3: OFF 1 2 3 4 3 A 4 2 A3:ON 1 2 3 4 A Panel Button Assignments 1=Pump 2 (A5 On)* 3=Temp Aux=J17/26 2=Pump 1 4=Light *1=Unused (A5 Off) http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 7 920-925-3094 VS525Z - 55666_97_A
  • 8. Ozone Connections Ozone Connector Voltage: The VS500Z circuit board is factory configured to deliver a preset voltage (120V or 240V) to the on-board ozone connector (J29). See the ratings table on the wiring diagram attached to the cover of the enclosure for the configured voltage. For 240V output W2 connects to Red AC and for 120V output W2 connects to White AC. The voltage to the ozone connector can be changed in the field if required. W2 just needs to be set for the required voltage. WARNING: Changing the voltage of the ozone connector also effects the voltage supplied to the circ pump connector (J47). Any equipment controlled by that connector may be damaged if the wrong voltage is selected. Balboa Ozone Generator: If the board is set up to operate a 120V ozone generator, the connector on the ozone generator is likely to be configured correctly, but should be compared to the illustration below. If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the connector next to the green ground wire as described below. Note: A special tool is required to remove the pins from the connector body once they are snapped in place. Check with your Balboa Account Manager for information on purchasing a pin-removal tool. Balboa Ozone connector configuration for 120V 60Hz B Line - Black conductor Use this slot for the leftover Red conductor Common - Install the White conductor here for 120V ozone G Ground (Green) conductor Flat sides of sockets as shown Balboa Ozone connector configuration for 240V 60Hz B Line - Black conductor Use this slot for the leftover White conductor Common - Install the Red conductor here for 240V ozone G Ground (Green) conductor FUSE 20A 250V J47 J46 J29 Line - Black conductor Circ.Pump R J20 F1 Use this slot for the leftover conductor B Common - Red for 240V or White for 120V ozone (See W2 wire) Ground (Green) conductor FUSE 3A 250V W Light W 12V W2 wire determines voltage W G K8 K5 W2 W3 J1 J1A J10 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 8 920-925-3094 VS525Z - 55666_97_A
  • 9. Duplex Panel Configurations VL200 (LCD Lite Digital) VL20 PN 52312 with Overlay PN 11127 5 Co Connects to Main Board terminal J1 DIP Switch A3 must be on VL240 (MVP240) Jets 2 Jets 1 Temp Light PN 55569 with Overlay PN 11764 (Gray Plastic) PN 53636 with no O/L (White Plastic) Connects to Main Board terminal J1 DIP Switch A3 must be on VL260 (MVP260) Overlay PN 11725 Jets Jets Temp Light PN 55049 with White Plastic PN 55050 with Gray Plastic PN 55051 with Clear Plastic Connects to Main Board terminal J1 DUPLEX DIP Switch A3 must be on VL400 PN 55129 with Overlay PN 11822 Connects to Main Board terminal J1 DIP Switch A3 must be off VL401 (LCD Lite Digital) PN 54251-01 with Overlay PN 11671 Connects to Main Board terminal J1 DIP Switch A3 must be off http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 9 920-925-3094 VS525Z - 55666_97_A
  • 10. Duplex Panel Configurations VL402 (LCD Super Duplex) PN 54107 with Overlay PN 10764 Connects to Main Board terminal J1 DIP Switch A3 must be off VL403 (LED Lite Digital) PN 54104 with Overlay PN 10752 Connects to Main Board terminal J1 DUPLEX DIP Switch A3 must be off VL404 (LED Digital Duplex) PN 51248 with Overlay PN 10418 Connects to Main Board terminal J1 DIP Switch A3 must be off VX10 AUX PN 55608 with Overlay PN 40107 Required for Blower Blower Jets 1 Connects to Main Board terminal J2 http://www.MyPoolSpas.com Wholesale Page and Spa Parts Pool 10 920-925-3094 VS525Z - 55666_97_A